首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundDiagnostic tests for hepatitis C virus (HCV) infection should be adapted according to the clinical status of the patient.ObjectivesWe exploited the application of different HCV diagnostic algorithms in a tertiary care hospital practice.Study designThe laboratory clinical reports to the medical orders for HCV testing during three years were clustered by different combinations of assays for anti-HCV antibodies (HCV Ab) (screening and confirmatory), HCV nucleic acid (HCV-RNA), HCV core antigen (HCV Ag). The latter was the first-line assay in acute HCV infections requiring a rapid assessment of the infectious state.ResultsThe majority (91.9%) of the 2726 subjects whose samples were analyzed were inpatients. Most of the patients/subjects were tested for clinical suspicion of viral hepatitis (49.2%), or occupational accident to health care professionals (20.0%). On 66% of samples HCV Ag test alone was performed and resulted positive in 116 cases (6%), while it was detected in 50.3% of anti-HCV positive samples. The agreement between HCV Ag and HCV-RNA was very high (k = 0.97); HCV Ag positivity rates increased according to the signal of the HCV Ab screening test.ConclusionsThe use of different testing strategies according to the patients’ history and clinical status allowed a significant reduction of the number of tests performed and the time needed to provide a diagnostic response useful for patients’ management without compromising the overall diagnostic accuracy for HCV infection.  相似文献   

2.
3.
A new, sensitive enzyme immunoassay has been developed for detecting and quantifying total hepatitis C virus (HCV) core antigen in anti-HCV positive or negative sera ("trak-C", Ortho Clinical Diagnostics, Raritan, NJ). The purpose of this study was to evaluate the performance of trak-C as an additional laboratory diagnostic marker of viraemia. The performance was compared to HCV-RNA detection in the "screening" of sera from a large heterogeneous population of hospitalised patients and outpatients. Six hundred and eighteen anti-HCV negative sera, 405 anti-HCV positive/HCV-RNA negative sera, 604 anti-HCV positive/HCV-RNA positive sera and 67 anti-HCV negative sera containing antigens or antibodies potentially interfering with the performance of the assay were analysed. Supplemental HCV antibody testing was performed using a commercial strip immunoblot assay. HCV-RNA was investigated using a qualitative commercial assay. A quantitative commercial RT-PCR was used for the analysis of selected samples. Sensitivity and specificity values were 94.7 and 100%, respectively. The latter was also confirmed when anti-HCV negative samples containing potentially interfering antigens/antibodies were examined. Sensitivity below 100% was probably due to an antigenaemia below the detection limit of trak-C. Besides, because 65.6% of HCV-RNA positive/trak-C negative samples presented specific antibodies against all four RIBA antigens, the hypothesis was raised that, in some cases, the dissociation step efficiency could be sub-optimal. In conclusion, trak-C seems suitable for identifying HCV infection on large based populations. It is a rapid to perform, reliable and specific assay that can be adapted to any laboratory setting.  相似文献   

4.
ObjectiveThis study compared two assays aimed at confirming the presence of anti-HCV antibodies (Ab) after a positive screening: Geenius HCV supplemental assay (Bio-Rad, Marne la Coquette, France) and the Inno-LIA HCV score assay (Fujirebio, Les Ulis, France).Material and methodsA total of 180 archived samples were investigated including 119 samples collected at different stages of HCV infection in 25 hemodialyzed patients who underwent HCV seroconversion, 14 samples from 4 commercial seroconversion panels, 47 Ab positive/HCV-RNA positive blood donations of which 7 showing an single reactivity in confirmatory assays. Samples were investigated and results were interpreted with the two assays according to the manufacturers’ instructions.ResultsOverall, Geenius and Inno-LIA were concordant for 84% (151/180) samples: 38 negative, 17 indeterminate and 96 positive. Of the 29 discrepant results, 26 were overclassified with Inno-LIA. HCV seroconversion was detected with Inno-LIA 4 and 7 days prior to Geenius in two panels. The high positive rate observed with Inno-LIA (64%) compared to Geenius (54%) was mainly due to low reactivities considered positive according to interpretation criteria, which could affect specificity.ConclusionAlthough HCV supplemental assays are not recommended for the diagnostic of HCV infection, which is primarily based on HCV-RNA testing, both assays are suitable as second line anti-HCV tests when Ab screening is positive and RNA testing cannot be performed. Moreover, Geenius system provides an objective result in less than 30 minutes, which is compatible when a rapid diagnostic is required.  相似文献   

5.
BackgroundHepatitis C virus (HCV) status cannot be reliably predicted in anti-HCV positive/HCV-RNA negative individuals who may either have recovered spontaneously or have a false-positive test due to antibody cross-reaction. Investigating T lymphocyte responses in individuals with different HCV status may help understand the cellular immune mechanisms underlying spontaneous recovery, treatment response, and chronicity.ObjectiveWe aimed to determine whether anti-HCV positive, HCV-RNA negative individuals are truly spontaneous recoverers from acute HCV infection.Study designWe used enzyme-linked immunosorbent spot (ELISPOT) assay to compare HCV-specific lymphocyte response among anti-HCV positive/HCV-RNA negative individuals, patients with sustained virological response to interferon-γ/ribavirin treatment, and patients with chronic HCV infection.ResultsWe found that 83% of anti-HCV positive/HCV-RNA negative individuals without a past medical history of acute icteric hepatitis had an HCV-specific T lymphocyte response in peripheral blood. Lymphocyte responses in these individuals were similar in magnitude to treatment responders unlike patients with chronic HCV whose virus-directed immunity was significantly suppressed.ConclusionsDetection of HCV-specific T lymphocyte responses using ELISPOT is a feasible method to ascertain past asymptomatic acute HCV infection.  相似文献   

6.
血清中丙型肝炎NS3抗原ELISA检测方法的建立和初步应用   总被引:1,自引:0,他引:1  
目的 评价血清中丙型肝炎病毒(HCV)游离NS3抗原的酶联免疫吸附(ELISA)检测方法的特异性和灵敏度,初步探讨该方法在临床应用中的意义.方法 对77例正常人血清标本,173例抗-HCV阳性标本和3708例抗-HCV阴性的其他类型肝炎血清标本检测HCV游离NS3抗原;对部分HCV NS3抗原阳性标本进行验证,包括HCV RNA测定、中和试验和免疫斑点试验;对11例患者的25份系列血清标本进行了HCV游离NS3抗原、HCV RNA和HCV抗体的联合检测,并结合临床资料综合分析.结果 3708例抗-HCV阴性的其他类型肝炎血清标本中有48例为HCV NS3抗原阳性,其中3030例单纯乙型肝炎和445例其他类型肝炎血清标本中分别有44例和4例为HCV NS3抗原阳性;173例HCV抗体阳性标本中有42例为HCV NS3抗原阳性;77例正常人血清标本的HCV NS3抗原检测结果均为阴性;15例HCV NS3抗原阳性标本中有9例为HCV RNA阳性;23例HCV NS3抗原阳性标本的中和率和免疫斑点试验的阳性率分别为87.0%和69.6%;25份系列血清标本的检测结果显示其HCV NS3抗原的吸光度值与时间呈负相关,并有2例HCV NS3抗原阳性标本随着血清中HCV NS3抗原的吸光度值下降,其HCV抗体转阳.结论 血清中HCV游离NS3抗原的ELISA检测方法有较好的特异性和敏感度,在发展中国家应用此方法进行HCV感染的早期诊断有一定的临床意义和推广价值.  相似文献   

7.
BackgroundDetection of antibodies (anti-HCV) against hepatitis C virus (HCV) is indispensable for screening and diagnosis of viral hepatitis and for the viral safety of blood, tissue or organ donations. It gains additional importance by the new HCV drugs which improve the therapeutic possibilities dramatically.ObjectiveTo evaluate the performance of a newly developed immune assay for anti-HCV based on the well-established VIDAS platform.Study designThe assay was evaluated with samples from anti-HCV negative blood donors and from patients with or without HCV markers in six centres in France, Spain and Egypt. The status of the samples was determined by using CE-marked immune assays (Architect, AxSym, Prism, Vitros), two immunoblots (RIBA, Inno-Lia) and/or HCV RNA results.ResultsSpecificity was 99.67% in 10,320 French blood donors without anti-HCV, 99.5% in 200 anti-HCV negative hospitalized European patients and 99.0% in 198 negative patients from Egypt. Sensitivity was 99.7% in 1054 patients pretested positive by other assays; 345 patients with known genotype had genotype 1–6; 61 patients were co-infected with HIV. VIDAS was reactive in 78% of 91 patients with uncertain or very weak anti-HCV. It became on average positive at day 37 with seroconversion panels.ConclusionsThis multicentric, international study with >12,000 samples show that the new VIDAS anti-HCV assay is very suitable for screening and confirmation of HCV infection. Sensitivity, specificity and recognition of seroconversion compare favorably with well-established CE-marked tests and help to clarify discrepant results obtained with other assays.  相似文献   

8.
《Clinical microbiology and infection》2020,26(12):1687.e1-1687.e5
ObjectiveTo evaluate the efficacy of sample pooling compared to the individual analysis for the diagnosis of coronavirus disease 2019 (COVID-19) by using different commercial platforms for nucleic acid extraction and amplification.MethodsA total of 3519 nasopharyngeal samples received at nine Spanish clinical microbiology laboratories were processed individually and in pools (342 pools of ten samples and 11 pools of nine samples) according to the existing methodology in place at each centre.ResultsWe found that 253 pools (2519 samples) were negative and 99 pools (990 samples) were positive; with 241 positive samples (6.85%), our pooling strategy would have saved 2167 PCR tests. For 29 pools (made out of 290 samples), we found discordant results when compared to their correspondent individual samples, as follows: in 22 of 29 pools (28 samples), minor discordances were found; for seven pools (7 samples), we found major discordances. Sensitivity, specificity and positive and negative predictive values for pooling were 97.10% (95% confidence interval (CI), 94.11–98.82), 100%, 100% and 99.79% (95% CI, 99.56–99.90) respectively; accuracy was 99.80% (95% CI, 99.59–99.92), and the kappa concordant coefficient was 0.984. The dilution of samples in our pooling strategy resulted in a median loss of 2.87 (95% CI, 2.46–3.28) cycle threshold (Ct) for E gene, 3.36 (95% CI, 2.89–3.85) Ct for the RdRP gene and 2.99 (95% CI, 2.56–3.43) Ct for the N gene.ConclusionsWe found a high efficiency of pooling strategies for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA testing across different RNA extraction and amplification platforms, with excellent performance in terms of sensitivity, specificity and positive and negative predictive values.  相似文献   

9.
BACKGROUND AND AIMS: The diagnosis of ongoing hepatitis C virus (HCV) infection involves the detection of specific antibodies and of HCV-RNA. We aimed to assess the relationship between these two parameters in a representative sample of a population at high risk for HCV infection. METHODS: Plasma and serum samples were respectively tested for HCV-RNA by a qualitative PCR (Cobas Amplicor HCV, Roche) and for HCV antibodies by a MEIA screening assay (AxSYM HCV 3.0, Abbott) and an immunoblot (Inno-LIA-III, Innogenetics). RESULTS AND CONCLUSIONS: Out of 888 samples assayed, 579 (65.2%) were positive for HCV-RNA, while anti-HCV antibodies were detected respectively in 802 sera by AxSYM (90.3%) and in 783 by LIA (706 positive and 77 indeterminate, 88.2%). The anti-core antibodies displayed the best correlation with viremia, since they were present in 97.1% of the PCR+ samples, followed by anti-NS3 (90.2%) and anti-NS4 (89.6%). Only one HCV-RNA positive sample was negative by LIA and MEIA (early seroconversion). The AxSYM sample/cutoff (S/CO) values were directly correlated with the presence of HCV-RNA: a PCR positivity was found in 4.9% of samples with a S/CO < or =10, in 60.8% of samples with a S/CO between 11 and 50 and in 93.6% of cases with a S/CO >50, (P < 0.005). The immunoblot adds little, on a single specimen, to the information yielded by the AxSYM screening test. A suitable diagnostic algorithm for HCV in high-risk settings could be the anti-HCV screening by MEIA and a qualitative assay for HCV-RNA on samples with low reactivity.  相似文献   

10.
A new diagnostic assay for hepatitis C virus RNA detection is described. HCV genomic RNA is captured onto streptavidin-coated magnetic beads by solution hybridization with biotinylated complementary oligonucleotides. The specificity of the capture assay is confirmed using different capture oligonucleotides as well as sera representing different types of HCV. Sensitivity was determined by testing serial dilutions of a HCV infected plasma. A panel of 50 sera was tested for anti-HCV by a Line Immunoassay and for HCV-RNA by both a conventional guanidinium extraction method and the new capture assay. The specificity of the capture assay was 95.8% and the sensitivity was 92.3% compared to the standard protocol. This method provides a rapid and simple alternative for HCV-RNA detection in blood samples. © 1994 Wiiey-Liss, Inc.  相似文献   

11.
A pooling system was developed for use in anti-HCV screening of voluntary blood donors at the local Central American Red Cross blood banks, in Nicaragua, El Salvador and Honduras. The commercially available second generation anti-HCV screening kit from Abbott Laboratories (North Chicago, IL) was used with a modification in the initial serum dilution procedure. Pools of five sera were selected for routine screening, based on comparative studies of individual samples and of pools with different sample sizes. During the years 1993 and 1994 a total of 89,148 voluntary blood donors were screened and a positive prevalence rate of 0.35% was established. Of the initially positive samples, 54% confirmed positive, 30% were indeterminate and 16% were negative using the Abbott Matrix test. Significant differences of positive screening prevalence rates were found in the three countries, with average values of 0.50%, 0.23% and 0.08%, respectively, in Nicaragua, El Salvador and Honduras. These initially positive samples also showed a different confirmatory pattern with a positive rate of 64% in Nicaragua, in contrast to 20% in El Salvador. Only a few samples were available for RT-PCR amplification of HCV-RNA; however, this highly sensitive method did not appear to be more helpful than serology in confirming the HCV donor status. Overall, the data obtained indicate a fluctuation of HCV prevalence in voluntary blood donors among the three Central American countries. Further, differences were found in the percentages of initially screened positives and confirmation patterns. This information appears useful for establishing criteria in future screening policies. Thus, we suggest that the use of pooling for anti-HCV screening is beneficial in countries under development, since there are potential cost savings, as well as benefits in establishment of initial prevalence rates. © 1996 Wiley-Liss, Inc.  相似文献   

12.
Paired serum-oral fluid samples from 127 hepatitis C virus (HCV)-positive and 31 HCV-negative patients were tested for the presence of anti-HCV using the Ortho HCV 3.0 ELISA. Using the immunoglobulin G (IgG)-specific detection antibody provided with the HCV 3.0 ELISA we attained 100% sensitivity and specificity with serum samples; however, sensitivity in oral fluid samples was only 81%. By modifying the HCV 3.0 ELISA to utilize a secondary antibody cocktail that recognizes not only IgG but IgA and IgM as well, we attained 100% specificity and sensitivity with oral fluid samples.  相似文献   

13.
Paired serum-oral fluid samples from 127 hepatitis C virus (HCV)-positive and 31 HCV-negative patients were tested for the presence of anti-HCV using the Ortho HCV 3.0 ELISA. Using the immunoglobulin G (IgG)-specific detection antibody provided with the HCV 3.0 ELISA we attained 100% sensitivity and specificity with serum samples; however, sensitivity in oral fluid samples was only 81%. By modifying the HCV 3.0 ELISA to utilize a secondary antibody cocktail that recognizes not only IgG but IgA and IgM as well, we attained 100% specificity and sensitivity with oral fluid samples.  相似文献   

14.
BackgroundThe gold standard for the diagnosis of acute hepatitis C (AHC) is seroconversion to anti-HCV/HCV-RNA positivity, an occurrence frequently missed in clinical practice.ObjectivesThis study aims to diagnose AHC by the combined use of the HCV Avidity Index (HCV-AI) and HCV-IgM titre.Study designWe enrolled 45 patients with AHC diagnosed by seroconversion to anti-HCV/HCV-RNA positivity and 36 with exacerbation of chronic hepatitis C (e-CHC) diagnosed at least 1 year earlier. HCV-IgM titres were determined by a commercial enzyme-linked immunosorbent assay (ELISA) and HCV-AI by an ELISA for detection of HCV IgG with a partial modification. For each test, specific cut-off values at four selected checking points were established during the observation (<10 days, 11–15 days, 16–20 days and >20 days from the onset of symptoms): for the HCV-IgM assay, the highest value in e-CHC +5% and for HCV-AI assay, the lowest value in e-CHC ?5%.ResultsAround 90% of patients with AHC or e-CHC were correctly diagnosed at all checking points by combining the results of both tests. This practice afforded an improvement in sensitivity for the diagnosis of AHC, with the highest values at first and third checking points (92.3% and 92.6%, respectively) and an improvement in negative predictive value (NPV), with the highest value at first checking point (92.6%).ConclusionsThe diagnosis of AHC, made by seroconversion to anti-HCV/HCV-RNA positivity, was confirmed in more than 90% of patients by combining the results of IgG Avidity Index (IgG-AI) and HCV-IgM obtained in a single serum sample.  相似文献   

15.
Abstract

The limitations of dominant methods-based on the detection of anti-HCV antibodies or HCV viremia currently used for the diagnosis of HCV infection enhance efforts to have a rapid, simple, sensitive, and specific alternative diagnostic approach to detect viral antigens. A highly reactive IgG antibody was raised to HCV-NS4 recombinant antigen. The produced antibody showed no cross-reactivity with the other HCV structural and nonstructural recombinant antigens (C1 + 2, C3 + 4, E2/NS1, NS3, NS5). The well established ELISA technique was adapted to detect the new target HCV-NS4 antigen in serum samples. Extremely high agreement was found between the results of ELISA and qualitative detection of HCV-RNA, using a RT-PCR test as a gold standard for the diagnosis of HCV infection. Based on these encouraging results, a novel enzyme immunoassay; dot-ELISA was developed for rapid (?5 min) and simple qualitative detection of the target HCV antigen in serum. The developed method detected the HCV target antigen in 95% of serum samples from HCV infected individuals, with a specificity of 97% using sera of noninfected individuals in comparison with PCR test. The antigen detection method showed high predictive values of positive (99%) and negative (90%). Moreover, the dot-ELISA could detect the HCV target antigen in sera negative for anti-HCV Abs, but positive for HCV-RNA, and in sera of HCV infected individuals with low viremia, as well as those with high viremia, using quantitative RT-PCR. Accordingly, the developed highly sensitive and specific HCV antigen detection method could be applied for mass screening of HCV infection.  相似文献   

16.
BackgroundTransfusion-transmitted infectious diseases remain a major concern for blood safety, particularly with hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Nucleic acid testing (NAT) in donor screening shortens the serologically negative window period and reduces virus transmission. The cobas MPX (Roche Molecular Systems, Inc., Branchburg, New Jersey) is a recently developed multiplex qualitative PCR system that enables the simultaneous detection of HBV, HCV, and HIV with improved sensitivity and throughput using cobas 6800 and 8800 instruments.ObjectivesThe aim of this study was to conduct an evaluation of the clinical sensitivity and specificity of cobas MPX detection of HBV, HCV, and HIV in clinical specimens.Study designAmong samples referred for HBV, HCV, and HIV-1 quantification at Severance Hospital, Yonsei University College of Medicine, positive samples were selected to evaluate sensitivity. A total of 843 samples was tested using both cobas MPX and COBAS AmpliPrep/COBAS TaqMan Tests for HBV, HCV, and HIV-1 using the cobas 8800 system and a COBAS TaqMan 96 analyzer, respectively. Samples that showed discrepancies were confirmed by nested PCR.ConclusionsThe cobas MPX achieved excellent sensitivity and specificity for the detection of HBV, HCV, and HIV-1 in clinical samples. We found that the lower limit of detection (LOD) of blood screening by NAT actually improves clinical sensitivity, and occult HBV infection prevalence among healthy employees of the hospital was rather high.  相似文献   

17.
BACKGROUND: The aim of this study was to determine the clinical benefit of a new combined antigen-antibody immunoenzymatic assay (Monolisa HCV Ag-Ab Ultra, Biorad) in the setting of acute HCV infection in HIV infected patients. PATIENTS AND METHODS: The performance of this assay was first evaluated in 160 HIV positive samples from uninfected and chronically HCV infected patients. To assess the performance of the Ag-Ab assay in the context of acute hepatitis C, 94 stored frozen serums from 20 recently diagnosed cases were retrospectively tested for HCV-RNA and presence of anti-HCV antibodies, in parallel with the new assay. RESULTS: In HIV infected patients, the sensitivity and specificity of the Ultra assay was 100% with a strong discrimination between positive and negative samples. In HCV acutely infected patients, the Ag-Ab assay significantly reduced the seronegative period, allowing an earlier diagnosis compared to a 3rd generation ELISA in 65% of the cases. The combined assay became positive on the same bleed as the first HCV-RNA detection for 13 patients out of 20. Nevertheless, in one case, characterized by an absence of seroconversion over one year but a continuous viral replication above 1 million IU/ml, the combined assay did not improve HCV infection diagnosis. CONCLUSION: Use of this new assay as a first line screening would significantly reduce the long seronegative window period seen in HCV infection allowing earlier HCV diagnosis and rapid clinical management. However, in case of clinical acute hepatitis C, sensitive HCV-RNA detection should remain the gold standard.  相似文献   

18.
Background/AimsThis study aimed to evaluate the cost-effectiveness of hepatitis C virus (HCV) screening compared to no screening in the Korean population from societal and healthcare system perspectives.MethodsA published decision-tree plus Markov model was used to compare the expected costs and quality-adjusted life years (QALY) between one-time universal HCV screening and no screening in the population aged 40–65 years using the National Health Examination (NHE) program. Input parameters were obtained from analyses of the National Health Insurance claims data, Korean HCV cohort data, or from the literature review. The population aged 40–65 years was simulated in a model spanning a lifetime from both the healthcare system and societal perspectives, which included the cost of productivity loss due to HCV-related deaths. The incremental cost-effectiveness ratio (ICER) between universal screening and no screening was estimated.ResultsThe HCV screening strategy had an ICER of $2,666/QALY and $431/QALY from the healthcare system and societal perspectives, respectively. Both ICERs were far less than the willingness-to-pay threshold of $25,000/QALY, showing that universal screening was highly cost-effective compared to no screening. In various sensitivity analyses, the most influential parameters on cost-effectiveness were the antibodies to HCV (anti-HCV) prevalence, screening costs, and treatment acceptance; however, all ICERs were consistently less than the threshold. If the anti-HCV prevalence was over 0.18%, screening could be cost-effective.ConclusionsOne-time universal HCV screening in the Korean population aged 40–65 years using NHE program would be highly cost-effective from both healthcare system and societal perspectives.  相似文献   

19.
20.
The mean prevalence of anti-hepatitis C virus (HCV) in Italy is 0.87%. It reaches 2% in Campania, Southern Italy. Approximately 50% of community acquired non-A, non-B (NANB) hepatitis cannot be associated with known parenteral exposure. A recent Italian study has shown that the only demonstrable risk factor in 9% of acute C/NANB hepatitis is dental treatment. There are no data on direct contamination by HCV of dental surgeries. Possible environmental contamination by HCV-RNA was investigated in dental surgeries after treatment of anti-HCV and HCV-RNA positive patients. Thirty-five anti-HCV and HCV-RNA positive patients with chronic hepatitis underwent dental treatment and were enrolled in this study. Eight had chronic persistent hepatitis (CPH), 23 chronic active hepatitis (CAH), and 4 cirrhosis. A total of 328 samples collected from instruments and surfaces were tested after dental treatment of 35 anti-HCV positive patients. The presence of HCV-RNA was determined by polymerase chain reaction (PCR) to evaluate contamination of instruments and surfaces in dental surgeries. Twenty (6.1%) out of 328 collected samples were positive for HCV-RNA. The positive samples were from work benches (two), air turbine handpieces (one), holders (four), suction units (one), forceps (four), dental mirrors (two), and burs (six) Our data indicate that there is extensive contamination by HCV of dental surgeries after treatment of anti-HCV patients and that if sterilisation and disinfection are inadequate there is the possible risk of transmission to susceptible individuals. © 1995 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号