首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.  相似文献   

2.
Rotator cuff: evaluation with fat-suppressed MR arthrography   总被引:11,自引:0,他引:11  
Palmer  WE; Brown  JH; Rosenthal  DI 《Radiology》1993,188(3):683
  相似文献   

3.
Rotator cuff tears: diagnostic performance of MR imaging   总被引:10,自引:0,他引:10  
To determine the diagnostic performance of magnetic resonance (MR) imaging in the evaluation of suspected rotator cuff tears, eight asymptomatic volunteers and 32 patients with rotator cuff tendonopathy who underwent surgery were examined with MR imaging. Twenty-four of these patients also underwent contrast arthrography. The ability of MR imaging to depict the size of cuff tears and the quality of torn tendon edges was also evaluated. The MR imaging and arthrographic studies were reviewed without knowledge of surgical results or of the other studies. A scoring system was developed and a score assigned to each patient's MR study. The sensitivity of MR imaging for all tears (partial and full thickness) was 0.91, and the specificity was 0.88; whereas the sensitivity and specificity of arthrography were each 0.71. The scoring system improved the sensitivity to 1.0 and the specificity to 0.92. Linear regression analysis showed excellent correlation between preoperative assessment of the size of rotator cuff tears and measurement at surgery (r = .95).  相似文献   

4.
5.
Rotator cuff: evaluation with US and MR imaging.   总被引:6,自引:0,他引:6  
Magnetic resonance (MR) and ultrasound (US) imaging are currently touted for assessment of rotator cuff disease. Optimum clinical imaging techniques include use of (a) a 1.5-T MR imaging unit with small planar coils, proton-density-weighted and T2-weighted fast spin-echo sequences, and 10-12-cm fields of view (yielding 400-470 x 500-625-microm in-plane spatial resolution) and (b) a state-of-the-art commercial US unit with insonation frequencies of 9-13 MHz (yielding 200-400-microm axial and lateral resolution). Proper diagnosis requires familiarity with normal anatomic characteristics and imaging pitfalls. Care must be taken to avoid sonographic tendon anisotropy and MR imaging magic angle effects, which can be misinterpreted as rotator cuff tear. At MR imaging, a complete cuff tear typically appears as either a hyperintense defect or a tendinous avulsion that extends from the bursal to the articular side of the cuff; a partial cuff tear typically appears as a focal hyperintense region that contacts only one surface of the cuff. Complete and partial tears manifest with a wide spectrum of findings at US. MR imaging and US are effective for evaluating rotator cuff injuries, with high reported accuracies for detection of complete tears but more disparate results for detection of partial tears.  相似文献   

6.
目的 对比评价肩关节MR造影三维 VIBE和常规二维TSE T1W序列对肩袖撕裂的诊断价值.方法 由2名影像诊断医师独立回顾对比分析99例肩关节造影三维 VIBE重建图像和常规二维TSE T1W序列图像,判定有无肩袖撕裂,分别计算其敏感性和特异性.采用McNemar检验评价2种方法诊断价值是否存在统计学差异.结果 99例患者中,肩关节镜证实肩袖撕裂为35例,其中全层撕裂为13例,部分撕裂为22例(关节侧撕裂8例,滑囊侧撕裂9例,腱内撕裂5例).三维 VIBE与常规二维TSE T1W序列对肩袖全层撕裂和关节侧撕裂均准确诊断.三维 VIBE对肩袖撕裂的敏感性和特异性分别为62.86%和96.88%(医师甲),60.00%和98.44%(医师乙);常规二维TSE T1W序列对肩袖撕裂的敏感性和特异性分别为60.00%和96.88%(医师甲),65.71%和96.88%(医师乙).三维 VIBE与常规二维TSE T1W序列的诊断性能无统计学差异.结论 肩关节MR造影三维 VIBE序列可以替代常规二维TSE T1W序列评价肩袖撕裂.  相似文献   

7.
Rotator cuff impingement syndrome: MR imaging   总被引:2,自引:0,他引:2  
  相似文献   

8.
A new class of radio frequency (RF) coils for magnetic resonance (MR) imaging and spectroscopy is introduced. The coils consist of two loop-gap resonators of equal diameters positioned along a common axis. They are tuned to the mode in which the current in the two loops flows in opposite directions. These coils are "decoupled" from a uniform excitation field of arbitrary orientation (including circularly polarized fields) by intrinsic decoupling and by means of back-to-back fast recovery diodes. Measurements made with the coils and a phantom saline tank indicate that the signal-to-noise ratio obtainable with these coils is almost identical to that obtained with single loops. Imaging of several anatomic areas, including knee, wrist, and shoulder, has been performed with a 1.5-T MR system that uses circularly polarized RF. A small series of patients with torn rotator cuffs underwent imaging. Difficulties in establishing the diagnosis with MR imaging because of anatomic complexity are illustrated. The value of pulse sequences with long repetition times to increase the signal intensity of fluid in the joint is shown.  相似文献   

9.
Thirty-eight patients with suspected rotator cuff tears were examined at 1.5 T by using a loop-gap resonator surface coil. The MR findings were compared prospectively in a blinded fashion with the results from double-contrast arthrography in all 38 patients, high-resolution sonography in 23 patients, and surgery in 16 patients. In the total group of 38 patients, MR imaging detected 22 of 22 tears and 14 of 16 intact cuffs as determined by arthrography. In the 16 surgically proved cases, MR and arthrography showed identical results, with 92% sensitivity in the diagnosis of 12 tears and 100% specificity in the diagnosis of four intact cuffs. In a subgroup of 23 patients, sonography detected nine of 15 tears and seven of eight intact cuffs as determined by comparison with arthrography. In 10 surgically proved cases, sonography was 63% sensitive in the diagnosis of eight rotator cuff tears and 50% specific in the diagnosis of two intact cuffs. For the diagnosis of rotator cuff tears, MR imaging is comparable to arthrography in both sensitivity and specificity. In this study, sonography was not as accurate in the diagnosis of rotator cuff tears as were the other two techniques. These results suggest that MR imaging should be considered the noninvasive test of choice for patients with suspected rotator cuff disease.  相似文献   

10.
11.
Peroneus longus and brevis tendon tears: MR imaging evaluation   总被引:4,自引:0,他引:4  
  相似文献   

12.
13.
Rotator cuff tears: correlation of sonographic and surgical findings   总被引:4,自引:0,他引:4  
Hodler  J; Fretz  CJ; Terrier  F; Gerber  C 《Radiology》1988,169(3):791-794
High-resolution, real-time sonography of the rotator cuff was performed in 51 shoulders, and the results were correlated with findings obtained during subsequent surgery. Prospective sensitivity of sonography in detection of a tear was 100%; specificity, 75%; and accuracy, 92%. Retrospective estimation of tear size on sonograms correlated well with the intraoperative measurements for small and moderate lesions. Large lesions were often underestimated sonographically. Retrospectively, partial tears were correctly diagnosed in seven patients, and bursal thickening was recognized in 17 patients. Sonography of the shoulder proved to be an accurate, noninvasive method for the diagnosis of complete rotator cuff tears. It is useful for estimating tear size and location and may be useful in recognizing partial tears.  相似文献   

14.
肩袖撕裂的肩关节MR造影评价   总被引:4,自引:1,他引:3  
目的 评价肩关节MR造影对肩袖撕裂的诊断价值。方法 分析32例病人的肩关节MR造影图像,评价内容包括肩袖肌腱、盂唇、肱二头肌长头腱,结果与肩关节镜及肩部开放手术比较。结果 以肩关节镜和手术结果为标准,32例病人包括14例全层撕裂,6例下表面部分撕裂,12例无撕裂。肩关节MR造影判定有无肩袖撕裂的敏感性、特异性和准确性都为100%;诊断全层撕裂的敏感性、特异性和准确性分别为100%、94%和97%。同时,肩关节MR造影还正确诊断了所有的多肌腱撕裂、合并的盂唇异常及肱二头肌长头腱异常。结论 肩关节MR造影可以准确、全面地评价肩袖撕裂。  相似文献   

15.
The purpose of this study was to determine the accuracy of sonography in the detection of rotator cuff tears. Eighty-one patients were referred by orthopedic specialists because of a clinical suspicion of rotator cuff tear. The standards of comparison were arthrography in 79 cases and surgery in two cases. The sonographic technique used was based on a review of the literature and experience gained by scanning normal subjects. The sonographic criteria for the diagnosis of a complete rotator cuff tear were a focal defect in the cuff or complete absence or nonvisualization of the cuff. All sonograms were interpreted prospectively without knowledge of arthrographic or surgical results. With arthrography as the standard of comparison for the diagnosis of rotator cuff tear, sonographic results included 15 true-positives, 52 true-negatives, eight false-negatives, and four false-positives. With surgery as the standard of comparison, the results were one true-positive and one true-negative sonogram. The sensitivity of sonography in detecting rotator cuff tear was 0.67, the specificity was 0.93, and the accuracy was 0.85. Our study found lower sensitivity and accuracy results for shoulder sonography than have been previously reported.  相似文献   

16.
Rotator cuff tears: evaluation using double-contrast shoulder arthrography   总被引:3,自引:0,他引:3  
Mink  JH; Harris  E; Rappaport  M 《Radiology》1985,157(3):621-623
To determine the accuracy of double-contrast arthrography in complete rotator cuff tears, we studied 805 patients thought to have a complete rotator cuff tear who had undergone double-contrast shoulder arthrography (DCSA) between 1978 and 1983. The results of this study indicate that DCSA is exquisitely sensitive and as accurate as the single-contrast examination. The site of disruption was directly visualized in 93% of cases, and the size of the defect and status of the torn tendon edges were reliably predicted. Such information may influence the surgeon in patient selection for operative repair as well as surgical approach.  相似文献   

17.
PURPOSE: The purpose of this work was to establish the optimal means of evaluation of the rotator cuff interval (RCI) and rotator interval capsule and demonstrate normal anatomy of the RCI using MR imaging and MR arthrography. METHOD: MR arthrography was performed in 32 cadaveric shoulders. In 20 cases, MR imaging was completed prior to arthrography. Pre- and postarthrography studies included standard imaging planes. Images were evaluated by the consensus of two musculoskeletal radiologists with attention to the RCI, rotator interval capsule (measurements on postarthrographic studies), and crossing structures. In five cases, specialized imaging planes were performed after arthrography. RESULTS: The RCI, rotator interval capsule, and crossing structures were best evaluated by MR arthrography. The anteroposterior dimension of the rotator interval capsule could be best depicted on postarthrogram images. CONCLUSION: MR arthrography, with both standard and specialized imaging planes, is a useful way to evaluate the RCI, the rotator interval capsule, and its crossing structures.  相似文献   

18.
Rotator cuff lesions: signal patterns at MR imaging   总被引:4,自引:0,他引:4  
The signal intensity patterns of rotator cuff lesions at magnetic resonance (MR) imaging were evaluated in 80 patients who had surgical correlation and in 13 asymptomatic individuals (14 shoulders). Six cadaver shoulders were examined with MR, and histologic correlation was obtained in four. All studies were performed at 1.5 T with a flexible circular surface coil. The accuracy of MR imaging in detection of full-thickness cuff tears (31 patients) was 0.95 and of partial thickness tears (16 patients), 0.84. The most common and accurate pattern for full-thickness cuff tears (22 of 31 tears) was a region of intense signal seen on T2-weighted images. Less often the torn region consisted of an extremely degenerated and attenuated tendon with moderate signal intensity or was obscured by low-signal-intensity scar. The intense signal pattern on T2-weighted images was also accurate, although a less common finding (seven of 16 cases), in the diagnosis of partial tears. Tendinitis was recognized as focal or diffuse regions of increased signal intensity or a nonhomogeneous pattern of increased signal often associated with tendinous enlargement. In some patients, manifestations of subacromial-subdeltoid bursitis was present. Tendon degeneration was also manifested as regions of increased signal intensity. Some similarity and overlap of signal patterns of partial interstitial tears, tendinitis, and tendon degeneration are observed.  相似文献   

19.
Meniscal tears: pathologic correlation with MR imaging   总被引:37,自引:0,他引:37  
Stoller  DW; Martin  C; Crues  JV  d; Kaplan  L; Mink  JH 《Radiology》1987,163(3):731-735
Menisci from 12 autopsies and above-knee amputations were imaged with magnetic resonance (MR) at 1.5 T and then sectioned for gross and histologic examination. A histologic staging system was developed and showed a one-to-one correlation with corresponding grades of MR signal intensities. Histologic stages 1 and 2 represented a continuum of degeneration culminating in stage 3 fibrocartilaginous tears, seen most frequently in posterior-horn segments of the medial meniscus. Correlation of histologic stages with MR signal intensity allows for an improved diagnostic reading of MR images.  相似文献   

20.
A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patients, T2-weighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号