首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Song HY  Jung HY  Park SI  Kim SB  Lee DH  Kang SG  Il Min Y 《Radiology》2000,217(2):551-557
PURPOSE: To investigate the safety and clinical effectiveness of covered retrievable expandable nitinol stents in 25 patients with a benign esophageal stricture. MATERIALS AND METHODS: Under fluoroscopic guidance, covered retrievable expandable nitinol stents were placed in 25 patients with a benign esophageal stricture and were removed with a retrieval hook 1-8 weeks later. RESULTS: Stent placement was successful in all patients, with no procedural complications. After stent placement, all patients could ingest solid food. The stents were successfully removed from all but two patients. One patient passed the stent via the rectum, and the other regurgitated a high cervical stent. After stent removal, one patient developed a small esophagobronchial fistula, which spontaneously sealed within 1 week of stent removal. After stent removal or migration, all patients could ingest solid food. During follow-up (mean, 13 months; range, 2-25 months) after stent removal or migration, 12 patients maintained their improvement in dysphagia and needed no further treatment. Thirteen patients with recurrence were treated by means of repeat balloon dilation. CONCLUSION: Use of retrievable expandable nitinol stents seems to be a safe and effective method of treatment in selected patients with benign esophageal strictures.  相似文献   

2.
PURPOSE: To evaluate the clinical effectiveness of polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stents in tracheobronchial strictures. MATERIALS AND METHODS: With fluoroscopic guidance, PTFE-covered retrievable expandable nitinol stents were placed in 15 symptomatic patients with benign (n = 6) or malignant (n = 9) tracheobronchial strictures. Complications and improvement in respiratory status were evaluated. Stents were removed electively 6 months after placement in benign strictures or if complications occurred. Membrane degradation or separation from the wire mesh was evaluated in removed stents. RESULTS: A total of 17 stents were successfully placed and were well tolerated in all patients. Sputum retention, stent migration, and tissue hyperplasia occurred in 23.5% (n = 4), 17.6% (n = 3), and 17.6% (n = 3) of stents, respectively. A total of 11 stents were successfully removed electively 6 months after placement (n = 4) or when complications occurred (n = 7). All 11 such stents were removed without difficulty with use of standard techniques, antecedent balloon dilation being necessary in two cases as a result of tissue hyperplasia. No removed stent showed signs of membrane degradation, and two removed stents showed signs of membrane separation from the mesh. CONCLUSIONS: PTFE-covered retrievable expandable nitinol stents were effective in the treatment of tracheobronchial strictures. Stent removal was easy with use of standard techniques, and no removed stent showed evidence of membrane degradation.  相似文献   

3.
Covered retrievable expandable nitinol stents were successfully placed in nine patients with tuberculous bronchial strictures refractory to balloon dilation. Complications included stent migration (n = 1) and tissue hyperplasia at the proximal portion of the stent (n = 2). During the follow-up period (5-52 months), stricture recurred in three of five patients (60%) after temporary stent placement for 2 months, whereas stricture did not recur in the other four patients after temporary stent placement for 6 months. Temporary placement of covered retrievable stents appears to be an effective method for the treatment of patients with tuberculous bronchial strictures refractory to balloon dilation.  相似文献   

4.
Song HY  Shim TS  Kang SG  Jung GS  Lee DY  Kim TH  Park S  Ahn YM  Kim WS 《Radiology》1999,213(3):905-912
A polyurethane-covered retrievable expandable stent was placed in 13 patients with tracheobronchial strictures. In four patients with benign strictures, the stent was removed with use of a retrieval hook 2-6 months after placement. After stent removal, three of the four patients did not need further treatment. The retrievable stent warrants further investigation in the treatment of tracheobronchial strictures.  相似文献   

5.

Purpose

To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH).

Materials and Methods

A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62–83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set.

Results

Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results.

Conclusions

Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH.  相似文献   

6.
暂时性食管支架成形术治疗儿童食管良性狭窄   总被引:1,自引:0,他引:1  
目的 评价儿童食管良性狭窄使用暂时性食管支架成形术治疗的疗效.方法 儿童烧灼性食管狭窄及食管术后吻合口狭窄患儿10例,支架置入前均先行食管吞钡检查,吞咽评分为3,并置入覆膜可回收支架.结果 支架置入后,所有患儿无明显并发症,并安全回收.支架置放期间所有患儿能进食固体食物,无吞咽困难.支架取出后6~12个月随访,患儿均能正常进食,吞咽评分为0.结论 应用暂时性支架成形术治疗儿童食管良性狭窄安全、有效.  相似文献   

7.
PURPOSE: The authors report their experience with three types of retrievable covered nitinol stents in patients with malignant esophageal strictures. MATERIALS AND METHODS: Three types of retrievable covered nitinol stents were designed. Type A stents were placed in 45 patients, type B stents were placed in 29 patients, and type C stents were placed in 34 patients. The stents were removed with use of a stent retrieval set under fluoroscopic guidance when the stents caused complications. Stent patency, symptom relief, survival rate, and complications were analyzed relative to stent type and radiation therapy. RESULTS: The timing of radiation and the stent type have significant effects on occurrence of complications such as stent migration and fistula formation (P =.002 and P = 0.029, respectively). Complications were significantly more frequent in patients with the type B stent than those with type A or type C stents (P =.008). Patients who underwent radiation therapy before stent placement or who underwent no radiation therapy experienced substantially less complications than those who underwent radiation therapy after stent placement (P =.005 and P <.001, respectively). The survival period was significantly longer in patients who underwent radiation therapy after stent placement than in the other groups (P =.034). Stents were removed from 15 patients (14%) 2 days to 16 weeks (mean, 4 weeks) after stent placement as a result of severe pain (n = 7), stent migration (n = 6), or stent deformity (n = 2). Stent removal was well tolerated in all patients. CONCLUSION: Use of retrievable covered nitinol stents seems to be a safe and effective method of treatment in patients with malignant esophageal strictures. However, removal of the stents was needed in 14% of the patients because of complications. Patients who underwent radiation therapy after stent placement and those with the type B stent experienced more complications than other patients.  相似文献   

8.
PURPOSE: To evaluate the feasibility of using a retrievable urethral stent and to evaluate whether granulation tissue resolves after stent removal in a canine urethra. MATERIALS AND METHODS: Polyurethane-covered retrievable 0.10-mm-thick (n = 11) or 0.15-mm-thick (n = 10) nitinol wire stents were placed in the urethras of 20 dogs. In one dog, a second stent was placed in the urethra because of complete migration of the first stent into the urinary bladder. The stents were removed with retrieval hook wires 4 weeks (n = 10) and 8 weeks (n = 10) after placement. Fourteen dogs were sacrificed just after stent removal, and the other six dogs were sacrificed 2 weeks after stent removal. Information concerning procedure success, stent migration, and tissue response was obtained. RESULTS: Stent placement was technically successful in all dogs. Follow-up urethrograms showed partial (n = 4) or complete (n = 1) stent migration. Stent removal failed in two dogs due to partial or complete migration. Granulation tissue was observed at both ends of the stent in 17 dogs. Urethrograms and urethral specimens obtained 2 weeks after stent removal showed diminished granulation tissue and decreased thickness of the papillary projections of the epithelium compared with results obtained immediately after stent removal. CONCLUSION: Although some design modifications are necessary to reduce current complications, the polyurethane-covered retrievable nitinol stent seems feasible for use in the urethra. Stent-induced granulation tissue formation improved after stent removal.  相似文献   

9.
Purpose: To assess the safety and clinical effectiveness of the parallel placement of covered retrievable expandable metallic stents in the palliative treatment of malignant esophageal and tracheobronchial strictures.

Material and Methods: Under fluoroscopic guidance, parallel stents were placed in 12 symptomatic patients with both malignant esophageal and tracheobronchial strictures. Seven of these 12 patients also had an esophagorespiratory fistula (ERF) and one patient had an esophagocutaneous fistula. Technical success, clinical improvement, complications, and survival rates were evaluated.

Results: A total of 28 esophageal and airway stents were successfully placed. The grade of dysphagia and dyspnea score significantly decreased after stent placement (P = 0.002 and 0.003, respectively). ERF and esophagocutaneous fistula were sealed off in all eight patients after esophageal stent placement; however, the esophagocutaneous fistula reopened 1 month later. Complications included stent migration or expectoration (n = 3), tracheal compression by the esophageal stent (n = 3), new fistula development due to covering membrane degradation of the esophageal stent (n = 1), and symptomatic sputum retention (n = 1). Stent removal was easily performed for two stents; one migrated stent and the other with covering membrane degradation. All 12 patients died within the mean survival period of 72.50 days (range 7-375 days).

Conclusion: Parallel placement of covered retrievable expandable metallic stents is safe and effective for the palliative treatment of malignant esophageal and tracheobronchial strictures.  相似文献   

10.
Temporary placement of a polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stent was performed to treat a benign anastomotic duodenojejunal stricture that was refractory to repeated balloon dilation procedures. The procedure provided a favorable outcome for the patient and was completed without complications. This result suggests that successful treatment of benign strictures of the gastric outlet or duodenum is possible with use of retrievable stents.  相似文献   

11.
Purpose: To evaluate the preliminary clinical efficacy and retrievability of a covered, retrievable, metallic hinged stent in the treatment of bronchial stump fistula (BPF).

Material and Methods: Between April 2003 and March 2005, eight patients with bronchial stump fistula after pneumonectomy or lobectomy were treated with two types of covered, retrievable, metallic hinged stents. Type A stent was placed in six patients and type B in two under fluoroscopic guidance. The stent was removed with a retrieval set when BPF was healed or complications occurred.

Results: Stent placement in the bronchial tree was technically successful in all patients, without procedure-related complications. Immediate closure of the BPF was achieved in all patients after the procedure. Stents were removed from all patients but one. Removal of the stents was difficult in two patients due to tissue hyperplasia. Patients were followed for 4-16 months. Placement of the stents remained stable in all patients except one due to severe cough. Permanent closure of BPF was achieved in seven (87.5%) of eight patients.

Conclusion: Use of a covered, retrievable, expandable, metallic hinged stent is a simple, safe, and effective procedure for the closure of bronchial stump fistula. Retrieval of the stent seems feasible.  相似文献   

12.
PURPOSE: To assess the clinical effectiveness of temporary metallic stent placement with concurrent radiation therapy in patients with esophageal carcinoma by comparing it with permanent stent placement with concurrent radiation therapy. MATERIALS AND METHODS: Covered retrievable expandable nitinol stents were placed in 47 patients with esophageal carcinoma 1 week before starting radiation therapy; the stents were electively removed 4 weeks after placement in 24 patients (group A), while not electively removed in the other 23 patients (group B). In cases of complications, the stents were also removed from patients in groups A and B. The dysphagia score, complications (severe pain, granulation tissue formation, stent migration, esophagorespiratory fistula, and hematemesis), tumor overgrowth/regrowth, reintervention rates, and dysphagia-progression-free and overall survival rates were compared in the two groups. RESULTS: Stent placement or removal was technically successful and well tolerated in all patients. The dysphagia score was significantly improved in both groups after stent placement (P < .01). Each of the stent-related complications was less in group A than in group B but there was no significant difference. However, the total number of patients with one or more than one complications and who needed related reinterventions was significantly less in group A than in group B (P = .042 and .030, respectively). Tumor overgrowth/regrowth and the total number of patients who required related reinterventions was not significantly different (P = 1.00 and .517, respectively). Dysphagia-progression-free and overall survival rates were significantly longer in group A than in group B (P = .005 and .001, respectively). CONCLUSION: Temporary placement of a covered retrievable expandable metallic stent with concurrent radiation therapy for patients with esophageal carcinoma is beneficial for reducing complications and related reinterventions and for increasing resultant survival rates compared with permanent esophageal stent placement.  相似文献   

13.
PURPOSE: To evaluate the safety and clinical effectiveness of a covered retrievable expandable nitinol stent for the treatment of malignant tracheobronchial stricture and/or esophagorespiratory fistula (ERF). MATERIALS AND METHODS: With fluoroscopic guidance, stents were placed in 35 symptomatic patients with malignant tracheobronchial stricture and/or ERF in most cases caused by lung or esophageal cancer. The site of stricture was most commonly at the trachea or left main bronchus. If there were complications, the stent was removed with a retrieval set. Nine patients had combined symptomatic ERF. RESULTS: A total of 47 tracheobronchial stents were placed and were technically successful and well-tolerated in all patients. Improvement of dyspnea was achieved in 92% of the patients (24 of 26 patients). Associated ERF in nine patients was effectively treated with tracheobronchial stent placement with or without esophageal stent placement. Stent migration, tumor overgrowth, symptomatic sputum retention, and hemoptysis occurred in 17% (6/35), 6% (2/35), 20% (7/35), and 17% (6/35) of patients, respectively. There were no documented cases of tumor ingrowth. Stent removal was performed easily in five patients when stent migration (n = 2), severe pain (n = 1), tumor overgrowth (n = 1), or persistent gastrobronchial fistula (n = 1) developed. All patients died 2 days to 26 weeks (mean, 9.62 weeks) after stent placement because of disease progression (n = 18), pneumonia (n = 9), hemoptysis (n = 5), or unknown cause (n = 3). CONCLUSION: Use of a covered retrievable expandable nitinol stent is a safe and effective method for relieving dyspnea. This procedure contributed to improved quality of life for patients with malignant tracheobronchial stricture and/or ERF. Stent retrievability was useful in resolving stent-related complications.  相似文献   

14.
Jung GS  Song HY  Kang SG  Huh JD  Park SJ  Koo JY  Cho YD 《Radiology》2000,216(3):758-763
PURPOSE: To investigate the technical feasibility and clinical effectiveness of a polyurethane-covered expandable nitinol stent in the treatment of malignant gastroduodenal obstructions. MATERIALS AND METHODS: The stent was constructed in-house by weaving a single thread of 0.2-mm nitinol wire in a tubular configuration and was covered with polyurethane solution by means of a dipping method. With fluoroscopic guidance, the stent was placed in 19 consecutive patients with malignant gastric outlet obstruction (n = 15) or duodenal obstruction (n = 4). All patients had severe nausea and recurrent vomiting, and their obstructions were inoperable. RESULTS: Stent placement was technically successful in all but one patient. After stent placement, symptoms improved in all but one patient, who had another stenosis at the proximal jejunum. One patient with stent placement in the second portion of the duodenum became jaundiced. During the mean follow-up of 11 weeks, stent migration occurred in five patients 1-4 days after the procedure. All patients with stent migration were treated by means of placing a second, uncovered nitinol stent. Two of these five patients showed recurrence of stricture because of tumor ingrowth; they underwent coaxial placement of a third, covered nitinol stent with good results. CONCLUSION: Placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible and effective for palliative treatment of inoperable malignant gastroduodenal obstructions. Stent migration, however, is problematic and requires further investigation.  相似文献   

15.
PURPOSE: To evaluate patency of refractory benign biliary strictures in liver transplant patients treated with retrievable stent-grafts. MATERIALS AND METHODS: Eight male liver transplant patients who ranged in age from 42 to 52 years developed nine symptomatic biliary strictures (intrahepatic left duct, 1; hilar, 2; anastomotic, 6). These strictures had recurred despite multiple previous attempts of treatment (n = 33), including angioplasty (n = 27), surgery (n = 1), atherectomy (n = 1), metallic stent (n = 1), and prolonged catheter drainage (n = 3). As an alternative method of treatment for these refractory biliary strictures, transhepatic placement of expanded polytetrafluoroethylene stent-grafts across the strictures was performed through 10-F sheaths. In total, 14 stent-grafts were placed to treat the nine lesions, and nine of these stent-grafts were subsequently retrieved through 12-16-F sheaths. RESULTS: Stent-grafts were deployed successfully. Delayed migrations in two patients required additional stent-graft placement. One patient died of pneumonia 1 month after stent-graft placement; the remaining seven patients had stent-grafts successfully removed at 3-10 months (mean, 5.6 months). Nine intended stent-graft retrievals were performed successfully, with two requiring use of elongated forceps. Immediately after treatment, all strictures were widely patent. Five to 6 months after stent-graft removal in these seven patients, significant strictures recurred in four of eight lesions (50%). One patient underwent surgical revision. At 6-29 months (mean, 12 months) after stent-graft removal, the remaining six patients were without clinical or laboratory evidence of biliary obstruction, despite three patients with significant recurrent strictures. CONCLUSION: Temporary stent-graft placement for treatment of benign biliary strictures in liver transplant patients is technically feasible. Longer follow-up with larger patient series is necessary to assess effectiveness and possible broader applications.  相似文献   

16.
ObjectiveTo investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent.Materials and MethodsWe retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11–92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures.ResultsStent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2–7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6–146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5–124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency.ConclusionLong-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.  相似文献   

17.
Objective To evaluate the preliminaily clinical efficacy and retrievability of a retrievable hinged covered metallic stent in the treatment of the bronchial stump fistula (BSF). Methods Between April 2003 and March 2005, 8 patients with bronchial stump fistula after pneumonectomy or lobectomy were treated with two types (A and B) of retrievable hinged covered metallic stents. Type A stent was placed in 6 patients and type B in 2 under fluoroscopic guidance. The stent was removed with a retrieval set when BSF was healed or complications occurred. Results Stent placement in the bronchial tree was technically successful in all patients, without procedure-related complications. Immediate closure of the BSF was achieved in all patients after the procedure. Stents were removed from all patients but one. Removal of the stents was difficult in two patients due to tissue hyperplasia. Patients were followed up for 6 - 21 months. Placement of the stents remained stable in all patients except one due to severe cough. Permanent closure of BSF was achieved in 7 (87.5%) of 8 patients. Conclusion Use of a retrievable hinged covered expandable metallic stent is a simple, safe, and effective procedure for closure of the BSF. Retrieval of the stent seems to be feasible. (J Intervent Radiol, 2007, 16: 253-257)  相似文献   

18.
We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9–348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent’s migration rate.  相似文献   

19.
The authors improved retrievable expandable metallic stent (REMS), instead of the nylon suture, the REMS was connected with the stainless steel thread. Under fluoroscopy the stainless steel thread of the shrinking body could be observed and was strong enough to retract the placed stent, then the stent could be removed by the stainless steel hook. We placed the REMS in the I.V.C. of canine, and removed them after one week placement, we could not remove them after two weeks placement. This study suggested that the REMS was considered to be useful and safe for clinical application.  相似文献   

20.
PURPOSE: To assess whether coaxial placement of uncovered and covered expandable nitinol stents overcomes the disadvantages of the increased migration rate seen with covered stents and the tumor ingrowth seen in uncovered stents in the treatment of malignant gastric outlet obstructions. MATERIALS AND METHODS: Two types of expandable nitinol stent were designed: an uncovered stent and a covered stent. Under fluoroscopic guidance, the uncovered and covered stents were placed coaxially with complete overlap in 39 consecutive patients with malignant gastric outlet obstruction caused by stomach cancer. Food intake capacity was graded on a scale of 0-4. Stent patency rate was estimated by the Kaplan-Meier method. RESULTS: Technical success rate was 97% (38 of 39 patients). After stent placement, food intake capacity improved at least one grade in 36 patients. Stent migration occurred in three patients (8%), that is, partial (n = 2) or complete (n = 1) upward migration of the inner covered stent into the stomach. Two of these patients were treated by placement of an additional covered stent. During the mean follow-up period of 134 days (range, 15-569 d), 10 patients developed recurrent symptoms of obstruction with tumor overgrowth being the most common cause. Nine underwent placement of an additional covered stent with good results. The median period of primary stent patency was 157 days (mean, 278 d). The 30-, 60-, and 180-day patency rates were 97%, 91%, and 39%, respectively. Four patients (10%) died within 1 month after the procedure. CONCLUSION: Coaxial stent placement technique seems to contribute to decreasing the migration rate of the stent and decrease the rate of recurrent obstruction by preventing or delaying tumor ingrowth.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号