首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background:

Dynamic hip screw (DHS) has been the standard treatment for stable trochanteric fracture patterns, but complications of lag screw cut out from a superior aspect, due to inadequate bone anchorage, occur frequently in elderly osteoporotic patients. Polymethylmethacrylate (PMMA) has been used as an augmentation tool to facilitate fixation stability in cadaveric femora for biomechanical studies and in pathological fractures. However, there are very few reports on the utilization of PMMA cement to prevent these complications in fresh intertrochanteric fractures. A prospective study was conducted to evaluate the outcome and efficacy of PMMA augmented DHS in elderly osteoporotic patients with intertrochanteric fractures.

Materials and Methods:

The study included 64 patients (AO type31-A2.1 in eight, A2.2 in 29, A2.3 in 17 patients, and 31-A3.1 in five, A3.2 in three, and A3.3 in two patients) with an average age of 72 years (60 – 94 years) of which 60 were available for final followup. PMMA augmentation of DHS was performed in all cases by injecting PMMA cement into the femoral head with a custommade gun designed by the authors. The clinical outcome was rated as per the Salvati and Wilson scoring system at the time of final followup of one year. Results were graded as excellent (score > 31), good (score 24 – 31), fair (score 16 – 23), and poor (score < 16).

Results:

Fracture united in all patients and the average time to union was 13.8 weeks (range 12 – 16 weeks). At an average followup of 18 months (range 12 – 24 months), no incidence of varus collapse or superior screw cut out was observed in any of the patients in spite of weightbearing ambulation from the early postoperative period. There was no incidence of avascular necrosis (AVN) or cement penetration into the joint in our series. Most of the patients were able to regain their prefracture mobility status with a mean hip pain score of 8.6.

Conclusion:

Cement augmentation of DHS appears to be an effective method of preventing osteoporosis related complications of fracture fixation in the trochanteric fractures. The technique used for cement augmentation in the present study is less likely to cause possible complications of cement augmentation like thermal necrosis, cement penetration into the joint, and AVN hip.  相似文献   

2.

Background:

The proximal femur nail antirotation (PFNA) is the recent addition to the growing list of intramedullary implants for trochanteric fracture fixation. The initial results in biomechanical and clinical studies have shown promise. We report our results of low velocity trochanteric fractures internally fixed by proximal femur nail antirotation.

Materials and Methods:

A prospective study was conducted to assess the results of 122 elderly patients with low velocity trochanteric fractures [39 – stable (AO; 31-A1) and 83 – unstable (AO; 31-A2 and A3)] treated with PFNA from December 2008 to April 2010. Followup functional and radiological assessments were done. Results obtained were compared between stable and unstable fracture patterns using statistical tools.

Results:

The mean followup was 21 months (12–28 months). 11 patients were lost in followup. Union was achieved in all but one patient. Varus collapse was seen in 14 patients and helical blade cut out in one patient. Stable and satisfactorily reduced fractures had a significantly better radiological outcome. Functional outcome measures were similar across fracture patterns. 65% of the patients returned to their preinjury status. The overall complication rate was also significantly higher in unstable fractures.

Conclusion:

Good results with relatively low complication rates can be achieved by PFNA in trochanteric fractures in the elderly. Attention to implant positioning, fracture reduction and a good learning curve is mandatory for successful outcomes.  相似文献   

3.

Background:

Allograft–prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft–prosthetic composites, but have rarely focused on the uncemented allograft–prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft–prosthetic composite and to present the radiographic and clinical results.

Materials and Methods:

Twelve patients who underwent uncemented allograft–prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated.

Results:

In our series, union occurred in all the patients (100%; range 5-9 months). Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS) score and Harris hip score (HHS) were 26.2 points (range 24-29 points) and 80.6 points (range 66.2-92.7 points), respectively.

Conclusions:

These results showed that uncemented allograft–prosthetic composite could promote bone union through compression at the host–allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.  相似文献   

4.

Background:

Most proximal femoral fractures are successfully treated with internal fixation but a failed surgery can be very distressing for the patient due to pain and disability. For the treating surgeon it can be a challenge to perform salvage operations. The purpose of this study was to evaluate the short-term functional outcome and complications of total hip arthroplasty (THA) following failed fixation of proximal hip fracture.

Materials and Methods:

In a retrospective study, 21 hips in 20 patients (13 females and seven males) with complications of operated hip fractures as indicated by either established nonunion or fracture collapse with hardware failure were analysed. Mean age of the patients was 62 years (range 38 years to 85 years). Nine patients were treated for femoral neck fracture, 10 for intertrochanteric (I/T) fracture and two for subtrochanteric (S/T) fracture of the hip. Uncemented THA was done in 11 cases, cemented THA in eight hip joints and hybrid THA in two patients.

Results:

The average duration of follow-up was four years (2-13 years). The mean duration of surgery was 125 min and blood loss was 1300 ml. There were three dislocations postoperatively. Two were managed conservatively and one was operated. There was one superficial infection and one deep infection. Only one patient required a walker while four required walking stick for ambulation. The mean Harris Hip score increased from 32 preoperatively to 79 postoperatively at one year interval.

Conclusion:

Total hip arthroplasty is an effective salvage procedure after failed osteosynthesis of hip fractures. Most patients have good pain relief and functional improvements inspite of technical difficulties and high complication rates than primary arthroplasty.  相似文献   

5.

Background

Greater trochanteric fracture/nonunion can be a devastating complication with significant functional impact after total hip arthroplasty, and their fixation remains a challenge because of the significant forces being transmitted as well as the poor bone quality often associated with these fractures. The objective of this study is to investigate the rates of reoperation and trochanteric nonunion using a third-generation cable-plate system at one center.

Methods

Thirty-five patients, mean age 72.9 years (range 46-98 years) with 24 women and 11 men, underwent fixation of their fractured greater trochanter using a third-generation cable-plate system. The indications were: periprosthetic fracture (n = 17), complex primary arthroplasty (n = 5), and complex revision arthroplasty (n = 13). Primary outcomes included rates of reoperation and radiographic union.

Results

At a mean follow-up of 2.5 years, trochanteric union rate was 62.9% with nonunion rate of 31.4%, and fibrous union in 5.7%. In regard to quality of initial apposition, only 40% achieved a perfect bone on bone reduction. Ten patients (28.6%) had evidence of wire breakage. Five patients (14.3%) required reoperation and removal of the internal fixation because of lateral hip pain.

Conclusion

Fixation of the trochanteric fractures remains a challenge with a relatively high reoperation rate. Poor bone quality and capacity to maintain a stable reduction continue to make this complication after total hip arthroplasty a difficult problem to solve.  相似文献   

6.

Background:

Nonunion of intertrochanteric fractures is uncommon because there is excellent blood supply and good cancellous bone in the intertrochanteric region of the femur. A diagnosis of primary intertrochanteric nonunion is made when at least 15 weeks after the fracture there is radiological evidence of a fracture line, with either no callus (atrophic) or with callus that does not bridge the fracture site (hypertrophic). There is only one published series that exclusively describes seven primary nonunions of intertrochanteric fractures. The aim of the present study was to analyze the results of internal fixation, valgization with 135° dynamic hip screw (DHS), and bone grafting in patients with primary nonunion of intertrochanteric fractures.

Materials and Methods:

Eighteen patients with primary intertrochanteric nonunion were included in the study; 16 were male and 2 were female. The age range was 30–70 years (mean: 46.9 years). The mean duration since index injury was 8.5 months (range: 4–18 months). As per the AO classification, the fractures were 31A 1.1 (n=1), 1.2 (n=1), 2.2 (n=3), 2.3 (n=9), and 3.3 (n=4). Three patients had hypermobile nonunion and 15 had stiff nonunion. The surgical principle was excision of pseudarthrosis, if present (n=3); freshening of the bone ends; stable fixation with 135° DHS, with good proximal purchase; bone grafting; and valgization.

Results:

Union was achieved in all patients at an average of 5.62 months (range: 4–7 months). The Harris hip score improved from 38 points preoperatively to 86 postoperatively at healing. The average limb shortening improved by 2 cm (range: 1.5 cm–3 cm). There was no infection and pain at the hip at final follow-up in any of the cases. All patients were subjectively satisfied with the outcome. All were capable of full weight bearing on their affected limb.

Conclusion:

Union in primary nonunion of intertrochanteric fractures in physiologically young patients with a well-preserved femoral head and good bone stock can be achieved with internal fixation, valgization, and grafting procedures.  相似文献   

7.

Background:

Failed infected internal fixation produces significant pain and functional disability. In infected internal fixation of hip fractures with partial or complete head destruction, total hip arthroplasty (THA) can be technically challenging; however, it restores hip biomechanics. The present study is to evaluate the results and assess the complications of THA following failed infected internal fixation of these fractures.

Materials and Methods:

A retrospective review of prospectively collected data in a tertiary healthcare center was performed of 20 consecutive patients of THA following failed infected internal fixation operated between September 2001 and November 2007. There were 11 dynamic hip screw failures for intertrochanteric fractures, 6 failed osteotomies following transcervical fractures, and 3 failed screw fixations for transcervical fractures.

Results:

The average age of the patients was 48.5 years (range 28-70 years) and the average followup period was 6.5 years (range 3.5-10.5 years). An indigenously designed cement spacer was used in a majority of patients (n = 15). The custom-made antibiotic impregnated cement spacer was prepared on-table, with the help of a K-nail bent at 130°, long stem Austin Moore''s prosthesis (n=1), Charnley''s prosthesis (n=1), or bent Rush nail (n=1). The antibiotic mixed cement was coated over the hardware in its doughy phase and appropriately shaped using an asepto syringe or an indigenously prepared spacer template. Nineteen of the 20 patients underwent two-stage revision surgeries. The average Harris hip score improved from 35.3 preoperatively to 82.85 postoperatively at the last followup. A significant difference was found (P < 0.0001). None of the patients had recurrence of infection.

Conclusions:

The results were comparable to primary arthroplasty in femoral neck fractures. Thus, THA is a useful salvage procedure for failed infected internal fixation of hip fractures.  相似文献   

8.

Background:

Hip replacement following failed internal fixation (dynamic hip screw for intertrochanteric fractures) or previous hip arthroplasty presents a major surgical challenge. Proximal fitting revision stems do not achieve adequate fixation. Distal fixation with long-stemmed extensively coated cementless implants (like the Solution™ system) affords a suitable solution. We present our early results of 15 patients treated with extensively coated cementless revision stems.

Materials and Methods:

Fifteen patients with severely compromised proximal femora following either failed hip arthroplasty or failed internal fixation (dynamic hip screw fixation for intertrochanteric fractures) were operated by the senior author over a two-year period. Eight patients had aseptic loosening of their femoral stems following cemented hip replacements, with severe thinning of their proximal cortices and impending stress fractures. Seven had secondary hip arthritis following failure of long implants for comminuted intertrochanteric or subtrochanteric femoral fractures. All patients were treated by removal of implant (cemented stems/DHS implants) and insertion of long-stemmed extensively coated cementless revision (‘SolutionDePuy, Warsaw (IN), US’) stems along with press-fit acetabular component (Duraloc Cup, DePuy, Warsaw (IN), US). All eight hip revisions needed extended trochanteric osteotomies.

Results:

All patients were primarily kept in bed on physiotherapy for six weeks and then gradually progressed to weight-bearing walking over the next six to eight weeks. The Harris Hip Scores and patient satisfaction were used for final evaluation. We achieved good results in the short term studied. In our first three patients (all following failed cemented total hip replacements), we resorted to cerclage wiring to hold osteotomised segments (done to facilitate stem removal). The subsequent 12 proceeded without the need for cerclage wiring. One patient had a intraoperative severe comminuted fracture extending into the supracondylar region while hammering in the stem. Post cerclage wiring, she was put on a long knee brace and her mobilization was delayed to 12 weeks.

Conclusions:

The extensively coated cementless (‘Solution™’) femoral stem provides a reasonable ‘solution’ to the deficient femur in hip revision. The proximal femoral deficiences can be relatively easily bypassed and distal fixation can be achieved with this stem. Extreme care needs to be taken to avoid fractures and penetration of the femoral shaft, which can, however, be managed by cerclage wiring. Principles of a successful outcome include preservation of the functional continuity of the abduction apparatus, care to recognize and prevent distal extension of fracture while inserting the stem (preemptive cerclage wiring) and supervised rehabilitation.  相似文献   

9.

Background:

Nonunion and avascular necrosis (AVN) of the femoral head remains one of the major complications following femoral neck fractures. Despite various surgical techniques and internal fixation devices, the incidence of nonunion and AVN has remained unsolved. Neglected nonunion of femoral neck fracture is common in the developing world. Treatment options include rigid internal fixation with or without bone grafting, muscle pedicle bone graft, valgus osteotomy of the proximal femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO).

Materials and Methods:

Over a period of 35 years (1974-2008), 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008), All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years). Results were analyzed in terms of radiological union at six months. Average followup was five years and six months.

Results:

Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°). Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore''s pins. These were reopened and cancellous screws were inserted in the same tracks.

Conclusions:

Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks.  相似文献   

10.

Background:

Ender and Simon Weidner popularized the concept of closed condylocephlic nailing for intertrochanteric fractures in 1970. The clinical experience of authors revealed that Ender nailing alone cannot provide secure fixation in elderly patients with osteoporosis. Hence we conducted a study to evaluate the efficacy of a combined fixation procedure using Ender nails and a cannulated compression screw for intertrochanteric fractures.

Materials and Methods:

76 patients with intertrochanteric fractures were treated using intramedullary Ender nails and cannulated compression screw from January 2004 to December 2007. The mean age of the patients was 80 years (range 70-105 years).Using the Evan’s system of classification 49 were stable and 27 unstable fractures. Inclusion criteria was high risk elderly patients (age > 70 years) with intertrochanteric fracture. The exclusion criteria included patients with pressure sores over the trochanteric region. Many patients had pre-existing co-morbidities like diabetes mellitus, hypertension, COPD, ischemic heart disease, CVA and coronary artery bypass surgery. The two Ender nails of 4.5mm each were passed across the fracture site into the proximal neck. This was reinforced with a 6.5 mm cannulated compression screw passed from the sub trochanteric region, across the fracture into the head.

Results:

The mean follow-up was 14 months (range 9-19 months) Average time to fracture union was 10 weeks (range 6-16 weeks). The mean knee ROM was 130° (± 5°). There was no case of nail penetration into hip joint. In five cases with advanced osteoporosis there was minimal migration of Ender nails distally.

Conclusions:

The Ender nailing combined with compression screw fixation in cases of intertrochanteric fractures in high risk elderly patients could achieve reliable fracture stability with minimal complications.  相似文献   

11.

Introduction:

Management of bone loss is a challenge in revision total hip arthroplasty (THA). A retrospective review was performed to study the use of uncemented distal locked prosthesis in cases with proximal femoral bone loss.

Materials and Methods:

Uncemented stems with distal interlocking were used in 65 hips during revision THAs with 38 hips having Paprosky IIIB/IV defects between January 1998 and February 2004. There were 48 males and 17 females in the study with an average age of 53 years (range 30-80 years). Radiographic and clinical outcome evaluation using the Harris hip score (HHS) were performed.

Results:

An improvement in HHS (mean: 33 points) was observed at final followup (mean: 9 years). Regeneration of proximal bone stock was observed without signs of loosening or subsidence and none of the stems were revised. Three patients developed recurrent dislocation while one had a stem subsidence of 1cm following removal of interlocking bolts.

Conclusion:

Uncemented distal locked prosthesis provide adequate stability in revision THA, aiding the reconstruction of bony deficiencies while avoiding the disadvantages of fully porous or cemented implants.  相似文献   

12.

Background and purpose

Treatment options for failed internal fixation of hip fractures include prosthetic replacement. We evaluated survival, complications, and radiographic outcome in 30 patients who were operated with a specific modular, uncemented hip reconstruction prosthesis as a salvage procedure after failed treatment of trochanteric and subtrochanteric fractures.

Patients and methods

We used data from the Swedish Hip Arthroplasty Register and journal files to analyze complications and survival. Initially, a high proportion of trochanteric fractures (7/10) were classified as unstable and 12 of 20 subtrochanteric fractures had an extension through the greater trochanter. Modes of failure after primary internal fixation were cutout (n = 12), migration of the femoral neck screw (n = 9), and other (n = 9).

Results

Mean age at the index operation with the modular prosthesis was 77 (52–93) years and the mean follow-up was 4 (1–9) years. Union of the remaining fracture fragments was observed in 26 hips, restoration of proximal bone defects in 16 hips, and bone ingrowth of the stem in 25 hips. Subsidence was evident in 4 cases. 1 patient was revised by component exchange because of recurrent dislocation, and another 6 patients were reoperated: 5 because of deep infections and 1 because of periprosthetic fracture. The cumulative 3-year survival for revision was 96% (95% CI: 89–100) and for any reoperation it was 83% (68–93).

Interpretation

The modular stem allowed fixation distal to the fracture system. Radiographic outcome was good. The rate of complications, however—especially infections—was high. We believe that preoperative laboratory screening for low-grade infection and synovial cultures could contribute to better treatment in some of these patients.The failure rate after surgery for extracapsular hip fractures is low. Occasionally, cutout and migration of the femoral neck screw occur regardless of whether a sliding hip screw or an intramedullary nail is used (Stern 2007). Implant failure after open or closed reduction and internal fixation is mostly seen in patients with unstable fracture patterns, poor bone quality, or poor positioning of the internal fixation device (Haidukewych et al. 2001).It is often difficult to find straightforward solutions. For younger patients, a second attempt at osteosynthesis with or without bone grafting may be favored. For elderly patients, prosthetic replacement is attractive, allowing immediate ambulation without fear of further fracture complications (Stern 2007).A salvage procedure converting failed internal fixation to a cemented primary total hip arthroplasty (THA) is challenging due to pre-existing and acquired osteoporosis, deformation of the trochanteric region, and difficulties in obtaining cement pressurization because of cortical screw holes (Zhang et al. 2004). Thus, an uncemented hip revision arthroplasty in these cases would appear attractive. These implants are designed to bypass regions of proximally deficient bone and to obtain stability and fixation in the distal femoral bone where there is good bone stock.There have been few reports on salvage THA with modular revision implants, and the numbers of patients have been limited (n = 10–23) (Laffosse et al. 2007, Talmo and Bono 2008, D’Arrigo et al. 2010, Abouelela 2011, Thakur et al. 2011). We reviewed a series of patients who had been operated with a specific modular, uncemented hip revision arthroplasty for failure of internal fixation of trochanteric and subtrochanteric fractures.  相似文献   

13.

Background:

The use of allografts and autografts in the management of acetabular defects have been reported with varying results. Trabecular metal is an expensive option in the management of these defects. This study aims to assess the fate and efficacy of bone grafting for acetabular bone defects in total hip arthroplasty.

Materials and Methods:

A total of 30 hips in 28 patients with acetabular deficiencies were treated with bone grafting and total hip replacement (THR). Seventeen hips had American Academy of Orthopedic Surgeons (AAOS) type 2 (Paprosky type 2c) deficiency and 13 had AAOS type 3 (Paprosky type 3a) defects of the acetabulum. Allografts were used in 15 patients and autografts were used in the remaining 13. Cemented total hip arthroplasty was done in 18 hips and uncemented THR in 12. Seven patients underwent the procedure for, acetabular erosion and symptoms following hemiarthroplasty (4 out of 7), or, acetabular revision for failure (3 out of 7) following total hip arthroplasty. Acetabular deficiencies in other patients were due to posttraumatic causes, advanced primary hip arthritis and second stage treatment of postinfective arthritis. A mesh was used in 6 hips and screws were used in 13 hips for graft fixation.

Results:

Patients were followed up clinicoradiologically for a period of 10 months to 4 years (mean 23.4 months). One patient required staged revision due to infection. Two patients had early asymptomatic cup migration. One patient had graft lysis and change in cup inclination with persistent pain. He was not keen on further intervention at last followup. Other patients were pain free at the time of followup with radiographs showing maintenance of graft and implant position.

Conclusion:

Bone grafting is a suitable option in the management of acetabular defects in total hip arthroplasty, especially in resource challenged countries.  相似文献   

14.

Background

Conversion hip arthroplasty is a salvage procedure for failed internal fixation of intertrochanteric fractures. However, the technical difficulties and perioperative morbidity of conversion arthroplasty are uncertain.

Methods

We compared the type of arthroplasty (total hip arthroplasty or hemiarthroplasty), operative parameters, perioperative morbidity, 1-year mortality, implant stability, and clinical results of 33 conversion hip arthroplasties due to a failed internal fixation of intertrochanteric fracture with those of a matched control group of 33 primary hip arthroplasties due to the same fracture. Propensity score was used for the control matching of gender, age, and body mass index.

Results

Total hip arthroplasty was more frequently performed in the conversion group (10/33) compared to the primary group (3/33) (P = .016). The operation time, perioperative blood loss, amount of transfusion, and risk of femoral fracture during the operation were increased in the conversion group. The overall 1-year mortality was 3% (1 patient) in the conversion group and 9% (3 patients) in the primary group (P = .307). At a mean of 3-year follow-up, there was no significant difference in clinical results and none of the implants were loose in both groups.

Conclusion

In patients with failed internal fixation of intertrochanteric fracture, conversion hip arthroplasty should be planned and executed, bearing in mind the increased operative morbidities corresponding to operation time, perioperative blood loss, requirement of transfusion, and intraoperative femoral fracture.  相似文献   

15.

Background

To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty.

Methods

This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiological results were evaluated by the Harris hip score and serial roentgenographic findings.

Results

The preoperative and postoperative Harris hip score was 68.3 and 92.5, respectively. Radiographically, none of the acetabular components showed any evidence of migration, tilt, rotation, or shedding of metal particles. In addition, none of the femoral components showed evidence of subsidence, pedestal, or shedding of metal particles. Twenty-two hips had a mild stress shield and 2 hips had a moderate stress shield. The perioperative complications encountered were deep vein thrombosis (1 case), mild heterotopic ossification (4 cases), intraoperative periprosthetic fractures (1 case), and nonunion of the trochanteric osteotomy site (2 cases).

Conclusions

Extensively porous coated femoral stems and acetabular components produce excellent clinical and radiological results in revision total hip arthroplasty.  相似文献   

16.

Background:

Osteoarthritis of the trapeziometacarpal joint of thumb occurs frequently and can be very disabling. Numerous surgical techniques including trapeziectomy with or without tendon interposition arthrodesis and partial or total joint arthroplasty with cemented and noncemented prosthesis have been described for the treatment of trapeziometacarpal joint osteoarthritis. Initial problems of osteolysis and implant loosening have been substantially reduced with improvement in implant design. The aim of this study is to demonstrate that trapeziometacarpal osteoarthritis of the thumb can be effectively treated with uncemented total joint replacement prosthesis.

Materials and Methods:

We retrospectively collected data for 16 trapeziometacarpal joint replacements in 14 patients. One patient was excluded as they required revision with trapeziectomy and ligament reconstruction following fracture of Trapezium. The trapeziometacarpal joint prosthesis was used in all cases and all operations were carried out by one surgeon. Clinical outcome was determined by a pre and postoperative patient rated wrist evaluation (PRWE) and Michigan Hand Questionnaire Score. Range of motion, grip, tip pinch and key pinch strength were measured and compared with the unoperated hand. Radiological assessment was carried out by plain radiographs for preoperative staging of arthritis and postoperative radiographs at latest followup for evaluation of osteolysis and implant loosening. Average followup period was 26 months.

Results:

There was an improvement in hand function and pain level based on PRWE and Mischigan Hand outcome Questionnaire Score. One patient had intraoperative fracture of Trapezium and subsequent radiographs at 14 months followup showed loosening of the trapezial component due to nonunion of the fracture and complete disintegration of the trapezium. There were no cases of dislocation or implant loosening for the remaining 15 CMC joints at the latest followup.

Conclusion:

The use of uncemented prosthesis in treatment of Questionnaire Score. Range of motion joint osteoarthritis gives excellent short term results in improving hand function in terms of strength and stability and achieving pain relief.  相似文献   

17.
18.

Background:

A high union rate (75%-100%) with a lower incidence of avascular necrosis (8%-9.3%) has been reported with intertrochanteric osteotomy in femoral neck fractures in elderly whereas arthroplasty eliminates the incidence of nonunion and avascular necrosis We present a series of femoral neck fracture in elderly treated with modified Pauwels’ intertrochanteric osteotomy and total hip arthroplasty for their functional outcome.

Materials and Methods:

29 elderly patients of 60 years and above sustaining fresh subcapital femoral neck fracture underwent total hip arthroplasty (group I, n=14) and modified Pauwels’ intertrochanteric osteotomy (group II, n=15). Functions were evaluated using modified Harris hip score, d''Aubigne and postel criteria and SF-36 score at 6, 12, 52 and 100 weeks.

Results:

The fracture union in group II was achieved in 14 (93.3%) patients at the fracture site at an average of 15 weeks and osteotomy united in all patients. Avascular necrosis of the femoral head was observed in one patient (6.7%). Average operative time was 88.9 and 65.6 minutes in group I and II, respectively (P value = 0.00001). An average of 0.8 and 0.2 unit blood was transfused in patients in group I and II, respectively (P value = 0.001). Average time of full weight bearing was 6.1 weeks and 11.6 weeks in group I and group II, respectively. At 100 weeks 71.4% (n = 10) patients in group I and 80% (n = 12) patients in group II showed good to excellent results on the basis of modified Harris hip score. 71.4% (n = 10) patients in group I and 66.6% (n = 10) patients in group II showed good to excellent results on the basis of d''Aubigne criteria. Average SF-36 score was 17.2% in group I and 17.6% in group II. Revision osteotomy was performed in one patient in group II because of implant cut through. Another patient in group II underwent THR because of painful hip. One patient in group I presented with dislocation after 3 weeks of surgery.

Conclusion:

Functional results of total hip arthroplasty and intertrochanteric osteotomy are comparable and the valgus intertrochanteric osteotomy with osteosynthesis in subcapital femoral neck fractures in elderly patients of sixty years and above may be considered as an option.  相似文献   

19.

Background

The treatment of unstable intertrochanteric fractures in elderly is still controversial. The purpose of this study is to present treatment strategies for unstable intertrochanteric fractures with hemiarthroplasty using standard uncemented collared femoral stems and at the same time preserving the fractured calcar fragment.

Methods

Fifty-four patients aged 75 years or older with unstable intertrochanteric fractures were included in this prospective cohort study. All patients were treated with calcar preserving hemiarthroplasty using cementless collored femoral stems. Fractured calcar fragment was stabilized either by compaction between the implant and femur or fixed with cable grip system. Follow-up evaluations were performed at least 24 months and later. Palmer and Parker mobility score and visual analogue scale (VAS) pain score were assessed. We also analyzed radiographs of the operated hip at each follow-up visit.

Results

The patients were 15 males and 39 females with a mean age of 81.3 years (range, 75 to 93 years). The average operative time was 86.6 minutes. The mean transfused blood units were 1.2 units. The average duration of hospital stay was 5.3 days. The preoperative mean mobility score was 6.20. This score was found to be 4.96 on postoperative third day and 5.90 at 24 months postoperatively. The results of the statistical analysis revealed significant increase in the mobility scores at each follow-up after three days. Radiological interpretation revealed no loosening in the cable-grip systems, and no significant subsidence (> 5 mm) of prosthesis was observed.

Conclusions

Calcar preservation arthroplasty is a good option for elderly patients with severe osteoporosis, frail constitution and the patients who are at higher risk for second operation due to unstable intertrochanteric fractures.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号