首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.  相似文献   

2.
We evaluated tricuspid regurgitation (TR) by multiple echocardiographic techniques in 93 consecutive patients who underwent standard two-dimensional (2D) and live three-dimensional (3D) transthoracic echocardiography (TTE). TR vena contracta (VC) area was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE dataset. Assessment of VC area by 3D TTE was compared to 2D TTE measurements of the ratio of TR regurgitant jet area to right atrial area (RJA/RAA), RJA alone, VC width, and calculated VC area. VC area from 3D TTE closely correlated with RJA/RAA and RJA alone as determined from 2D TTE measurements. Live 3D TTE color Doppler measurements of VC area can be used for quantitative assessment of TR and offer incremental value for quantification of particularly severe regurgitant lesions.  相似文献   

3.
We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.  相似文献   

4.
We evaluated 44 consecutive patients who underwent standard two-dimensional (2D) and live three-dimensional (3D) transthoracic echocardiography (TTE), as well as left heart catheterization with left ventriculography. Mitral regurgitant vena contracta area (VCA) was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE data set. Assessment of mitral regurgitation (MR) by ventriculography was compared to measurements of VCA by 3D TTE and to 2D TTE measurements of MR jet area to left atrial area (RJA/LAA), RJA alone, vena contracta width (VCW), and calculated VCA. VCA from 3D TTE closely correlated with angiographic grading (rs=0.88) with very little overlap. VCA of <0.2 cm2 correlated with mild MR, 0.2-0.4 cm2 with moderate MR, and >0.4 cm2 with severe MR by angiography. Ventriculographic grading also correlated well with 2D TTE measurements of RJA/LAA (rs=0.79) and RJA alone (rs=0.76) but with more overlap. Assessment of VCW and calculated VCA by 2D TTE agreed least with ventriculography (rs=0.51 and rs=0.55, respectively). Live 3D TTE color Doppler measurements of VCA can be used for quantitative assessment of MR and is comparable to assessment by ventriculography.  相似文献   

5.
We report the usefulness of live/real time three-dimensional transthoracic echocardiography in the visualization of Chiari network.  相似文献   

6.
Aortopulmonary (AP) window is an extremely rare congenital anomaly involving a communication between the ascending aorta and pulmonary artery. Two-dimensional transthoracic echocardiography is traditionally used in the diagnosis but has limitations. We report the usefulness of three-dimensional transthoracic echocardiography in the assessment of AP window in two newborns studied by us.  相似文献   

7.
We describe an adult in whom live/real time three-dimensional echocardiography was able to make a definite diagnosis of a quadricuspid aortic valve which was misdiagnosed as bicuspid by live two-dimensional transthoracic echocardiography (2DTTE).  相似文献   

8.
In the present study, we describe the usefulness of the recently developed technique of live three-dimensional transthoracic echocardiography in the assessment of normal cardiac structures and adjacent vessels using the right parasternal and supraclavicular approaches. Examples of some abnormalities diagnosed from these approaches are also illustrated.  相似文献   

9.
In this report, we evaluate 56 consecutive adult patients who underwent standard two-dimensional (2D) and live three-dimensional transthoracic echocardiography (3D TTE), as well as left heart catheterization with aortography (45 patients) or cardiac surgery (11 patients), for evaluation of aortic insufficiency. Similar to the method we previously described for mitral insufficiency, aortic regurgitant vena contracta area (VCA) was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE data set. Assessments of aortic regurgitation (AR) by aortography and surgery are compared to measurements of VCA by 3D TTE and to 2D TTE measurements of vena contracta width (VCW). Aortographic or surgical grading correlated well with 2D TTE measurements of VCW (r = 0.92), but correlated better with 3D TTE measurements of VCA (r = 0.95), with improved dispersion between angiographic grades demonstrated by the 3D TTE technique. Live 3D TTE color Doppler measurements of VCA can be used for accurate assessment of AR and are comparable to assessment by aortography.  相似文献   

10.
We describe an adult patient with a primary left atrial leiomyosarcoma in whom live/real time three-dimensional transthoracic echocardiography showed echolucent areas within the mass consistent with necrosis or hemorrhage surrounded by dense band-like echo densities indicative of fibrosis or collagen giving a "doughnut" like appearance. These findings were consistent with histopathology, which showed areas of necrosis and dilated vascular channels within the fibrotic tumor. Our case further illustrates the usefulness of three-dimensional transthoracic echocardiography in characterizing the morphologic features of an intracardiac mass.  相似文献   

11.
Twenty-nine patients with different tricuspid valve (TV) pathologies were studied by both two-dimensional transthoracic (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE). A major contribution of 3DTTE over 2DTTE was the en face visualization of all three leaflets of the TV in all patients. This allowed accurate assessment of TV orifice area in patients with TV stenosis and carcinoid disease. Loss of TV leaflet tissue, defects in TV leaflets and size of TV systolic non-coaptation could also be delineated and resulted in identifying the mechanism of tricuspid regurgitation (TR) in patients with Ebstein's anomaly and rheumatic heart disease. Prolapse of TV leaflets could also be well visualized and enabled us to develop a schema for systematic assessment of individual segment prolapse which could help in surgical planning. The exact sites of chordae rupture in patients with flail TV as well as right ventricular papillary muscle rupture could be well seen by 3DTTE. 3DTTE also permitted sectioning of various TV masses for more specific diagnosis of their nature. In addition, color Doppler 3DTTE provided an estimate of quantitative evaluation of TR severity, since the exact shape and size of the vena contracta could be accurately assessed. In conclusion, our preliminary experience with 3DTTE has demonstrated substantial incremental value over 2DTTE in the assessment of various TV pathologies.  相似文献   

12.
In this report, we review the advantages, limitations, and optimal utilization of various transthoracic and transesophageal echocardiographic (TTE and TEE) methods used for assessing mitral regurgitation (MR) as published in full-length, peer-reviewed articles since the color Doppler era began in 1984. In addition, comparison is made to other imaging modalities including catheter-based, magnetic resonance and surgical assessment of MR. Although left ventricular (LV) angiography has been traditionally used for validation of various TTE methods and is time-honored, its considerable limitations preclude it from being a real "gold standard." Based on the reviewed literature, no clear "gold standard" for the assessment of MR can be identified at present, but newly emerging TTE and TEE techniques, such as three-dimensional color Doppler, may have the potential to overcome some of the limitations of the two-dimensional methods.  相似文献   

13.
Background: Three-dimensional (3D) transesophageal echocardiography (TEE) enables the determination of the vena contracta area (VCA), which is an approved parameter to quantify mitral regurgitation (MR). The aim of this study was to determine the VCA in the operative setting and to compare it to alternative 3D and standard 2D methods, with respect to different etiologies of MR. Methods: MR in 56 consecutive patients undergoing cardiac surgery was evaluated using 2D and 3D TEE. VCA, vena contracta (VC), and effective regurgitation orifice area (EROA) by 3D and 2D flow convergence methods were determined. The correlations among the methods and the determined areas were evaluated. Results: EROA determination using 3D flow convergence areas correlated strongly with VCA (r = 0.653), however the resulting areas were considerably smaller. VC measurements in the 3D data set correlated slightly less (r = 0.629). EROA, which was determined using 2D flow convergence areas, showed the strongest correlation among the 2D methods (r = 0.406). 2D VC measurements showed weak to no correlation with VCA. Although a correlation was detected when using the biplane method or the midesophageal long-axis view to measure VC, statistical significance was only reached in functional MR and MR due to simple prolapse. Conclusions: Intraoperative 3D methods to determine MR were feasible and showed improved correlation with VCA compared to 2D measurements. The agreement of 2D methods with VCA declined from functional MR to MR due to prolapse. We recommend the utilization of 3D color Doppler for intraoperative evaluation of MR, especially in patients with complex mitral valve prolapses.  相似文献   

14.
We describe a patient in whom a mycotic aneurysm involving the distal descending thoracic aorta could be definitively diagnosed by live/real time three-dimensional transthoracic echocardiography.  相似文献   

15.
We describe live/real time three-dimensional transthoracic echocardiographic features of a chordoma metastatic to the heart and correlate its appearance with the surgical pathology.  相似文献   

16.
In the present study, we report our experience of using live three-dimensional transthoracic echocardiography in the assessment of aortic dissection in ten adult patients. To our knowledge, this has not been reported previously.  相似文献   

17.
We describe our experience in using live/real time three-dimensional transthoracic echocardiography (3D TTE) in the assessment of five adult patients with Ebstein's anomaly. The technique was found useful in assessing the distribution and extent of tethering of each of the three leaflets of the tricuspid valve (TV) to the underlying right ventricular walls and the ventricular septum. The characteristic bubble-like appearance resulting from bulging of the non-tethered areas of the TV leaflets was also well visualized in three dimensions and their size measured. Thus, an estimate of the nontethered or free segments of all three leaflets of the TV could be obtained using this technique. This has important implications when considering these patients for surgical repair of the TV. Visualization of all three leaflets of the TV and their extent of tethering by 3D TTE also made it easier to identify the boundaries of the functioning right ventricular chamber potentially providing a more reliable assessment of its volumes and ejection fraction. Cropping of color Doppler 3D TTE data sets provided en face viewing of the TV regurgitation vena contracta permitting accurate assessment of its shape and size. This has the potential to provide a more accurate quantitative estimation of TV regurgitation severity as compared to two-dimensional color Doppler. In conclusion, live/real time 3D TTE appears useful in supplementing two-dimensional echocardiography in more comprehensively assessing the morphologic features of Ebstein's anomaly.  相似文献   

18.
In the present study, we are illustrating some of the adult patients in whom live three-dimensional transthoracic echocardiography was found useful in assessing proximal and mid-coronary arteries.  相似文献   

19.
20.
Pericardial cysts are rare anomalies of the pericardium that are usually asymptomatic and followed by two-dimensional (2D) echocardiography. Here we report a large pericardial cyst that could not be measured accurately by 2D echocardiography but three-dimensional (3D) echocardiography enabled measurements of the cyst that correlated well with computed tomography measurements. In addition, 3D echocardiography demonstrated the mono-trabeculated nature of the cyst further suggesting the incremental value of 3D echocardiography in the evaluation of pericardial cysts. The cyst was subsequently resected surgically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号