首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We studied prospectively the long-term results of the Charnley Elite-Plus femoral stem in 184 consecutive young patients (194 hips). There were 130 men and 54 women with a mean age of 49.1 years (21 to 60). The predominant diagnosis was osteonecrosis of the femoral head (63.6%, 117 patients). Clinical and radiological evaluation was undertaken at each follow-up. The mean follow-up was 11.2 years (10 to 12). The mean pre-operative Harris hip score was 43.4 (12 to 49) which improved to 91 (59 to 100) at the final follow-up. The survival of the femoral stem at 12 years was 99% with revision as the end-point. The mean annual linear wear of the polyethylene liner was 0.17 mm (0.13 to 0.22). The prevalence of acetabular osteolysis was 10.8% (21 hips) and osteolysis of the calcar femorale 12.9% (25 hips). A third-generation cementing technique, accurate alignment of the stem and the use of a 22 mm zirconia head were important factors in the prevention of aseptic loosening of the Elite Plus femoral stem in these high-risk young patients.  相似文献   

2.
Between 1990 and 1992, we implanted 71 hybrid alumina-on-alumina hip arthroplasties in 62 consecutive patients under the age of 55 years, with a mean age of 46 years at surgery. There were 56 primary and 15 secondary procedures. The prostheses involved a cemented titanium alloy stem, a 32 mm alumina head, and a press-fit metal-backed socket with an alumina insert. Three patients (four hips) died from unrelated causes. Four hips had revision surgery for either deep infection, unexplained persistent pain, fracture of the alumina head, or aseptic loosening of the socket. The nine-year survival rate was 93.7% with revision for any cause as the end-point and 98.4% with revision for aseptic loosening as the end-point. The outcome in the surviving patients (50 patients, 57 hips) with a minimum five-year follow-up (mean eight years) was excellent in 47 hips (82.5%), very good in eight (14%), good in one and fair in one. A thin, partial, lucent line, mainly in zone III was present in 38% of the sockets and one socket had a complete lucency less than 1 mm thick. One stem had isolated femoral osteolysis. There was no detectable component migration nor acetabular osteolysis. This hybrid arthroplasty gave satisfactory medium-term results in active patients. The press-fit metal-backed socket appeared to have reliable fixation in alumina-on-alumina hip arthroplasty. The excellent results using cemented fixation of the stem may be related to the low production of wear debris.  相似文献   

3.
We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up. The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips. All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure. Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p < 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p < 0.001). The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis. Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.  相似文献   

4.
This study presents the results of a prospective, consecutive series of 50 patients (60 hips) who were observed for a minimum of 6 years after they had a primary total hip arthroplasty with a cementless Duraloc 100 series cup (DePuy, Warsaw, IN) with a close proximal fit and short tapered distal stem prosthesis (IPS hip; DePuy, Leeds, UK). There were 37 men and 13 women; the mean age was 46.6 years (range, 26 to 70 years). The mean follow-up was 6.3 years (range, 6 to 7 years). The mean preoperative Harris hip score was 42 points, which improved to 96 points at the final follow-up examination. The prevalence of transitory thigh pain was 2%. All hips had a satisfactory fit of the femoral stem in coronal (average, 88%) and sagittal (average, 94%) planes. There was no aseptic loosening or revision of the components. The wear rate per year was 0.23 mm. Four hips (7%) had osteolysis in the calcar femorale <1 cm in diameter. Although there was no aseptic loosening of the components, a low incidence of osteolysis, and a low incidence of thigh pain, a high rate of polyethylene liner wear in these young patients is a problem.  相似文献   

5.
We determined the midterm survival, incidence of peri-prosthetic fracture and the enhancement of the width of the femur when combining struts and impacted bone allografts in 24 patients (25 hips) with severe femoral bone loss who underwent revision hip surgery. The pre-operative diagnosis was aseptic loosening in 16 hips, second-stage reconstruction in seven, peri-prosthetic fracture in one and stem fracture in one hip. A total of 14 hips presented with an Endoklinik grade 4 defect and 11 hips a grade 3 defect. The mean pre-operative Merle D'Aubigné and Postel score was 5.5 points (1 to 8). The survivorship was 96% (95% confidence interval 72 to 98) at a mean of 54.5 months (36?to 109). The mean functional score was 17.3 points (16 to 18). One patient in which the strut did not completely bypass the femoral defect was further revised using a long cemented stem due to peri-prosthetic fracture at six months post-operatively. The mean subsidence of the stem was 1.6 mm (1 to 3). There was no evidence of osteolysis, resorption or radiolucencies during follow-up in any hip. Femoral width was enhanced by a mean of 41% (19% to 82%). A total of 24 hips had partial or complete bridging of the strut allografts. This combined biological method was associated with a favourable survivorship, a low incidence of peri-prosthetic fracture and enhancement of the width of the femur in revision total hip replacement in patients with severe proximal femoral bone loss.  相似文献   

6.
A ten- to 15-year follow-up of the cementless spotorno stem   总被引:6,自引:0,他引:6  
We followed the first 354 consecutive implantations of a cementless, double-tapered straight femoral stem in 326 patients. Follow-up was at a mean of 12 years (10 to 15). The mean age of the patients was 57 years (13 to 81). At follow-up, 56 patients (59 hips) had died, and eight (eight hips) had been lost to follow-up. Twenty-five hips underwent femoral revision, eight for infection, three for periprosthetic fracture and 14 for aseptic loosening. The overall survival was 92% at 12 years (95% CI 88 to 95). Survival with femoral revision for aseptic loosening as an endpoint was 95% (95% CI 92 to 98). The median Harris hip score at follow-up was 84 points (23 to 100). Radiolucent lines (< 2 mm) in Gruen zones 1 and 7 were present in 38 (16%) and 34 hips (14%), respectively. Radiolucencies in zones 2 to 6 were found in five hips (2%). The results for mid- to long-term survival with this femoral component are encouraging and compare with those achieved in primary cemented total hip arthroplasty. The high rate of loosening of the cup and the high rate of pain are, however, a source of concern.  相似文献   

7.
目的 探讨应用锥形沟槽设计的股骨组配柄假体行全髋关节股骨侧假体翻修术的中期疗效.方法 2000年5月至2005年8月采用锥形沟槽式股骨组配柄假体行全髋关节翻修术19例,男6例,女13例;年龄47~86岁,平均67岁.单髋17例,双髋2例.术前诊断均为股骨柄和臼杯假体无菌性松动合并股骨侧骨缺损,按Paprosky标准诊断为Ⅱ型缺损4髋,Ⅲa型缺损14髋,Ⅲb型缺损3髋.股骨侧翻修均采用锥形沟槽式股骨组配柄假体(Lima-Lto,意大利),髋臼侧均采用SPH臼杯假体(LimaLto,意大利)行生物学固定.关节头臼界面采用陶瓷-陶瓷组合17髋,金属-聚乙烯组合4髋.结果 全部病例随访5~10年,平均7年.Harris髋关节评分由术前平均(46.2±15.2)分改善至翻修术后半年平均(90.3±5.3)分,末次随访平均(92.2±3.5)分.X线片显示翻修柄获广泛骨长入骨性固定者20髋(95%,20/21),纤维性稳定者1髋(5%,1/21).假体下沉0~10 mm,平均2.4 mm.随访期间无一例因假体松动或其他原因需行再次翻修.结论 采用锥形沟槽式股骨组配柄假体行伴有PaproskyⅡ型、Ⅲa和Ⅲb型骨缺损的股骨侧假体翻修术,可获得理想的初始稳定和永久生物学固定,中期随访疗效满意.
Abstract:
Objective To evaluate the midterm results of the revision total hip replacement with a fluted and tapered modular stem. Methods Nineteen patients (21 hips) underwent revision total hip arthroplasty from May 2000 to August 2005 were reviewed. There were 13 females and 6 males, with an average age of 67 years. Pre-revision diagnosis included aseptic loosening of the cups and stems associated with femoral defects (Paprosky classification) type Ⅱ 4 hips (19%), type Ⅲa 14 hips (67%), and type Ⅲb 3 hips (14%). The adopted acetabular component was SPH (Lima-Lto, Italy), and femoral component was a fluted and tapered modular stem (Lima-Lto, Italy). Clinical and radiographic evaluations were performed postoperatively. Results The mean follow-up was 7 years (range, 5-10). The Harris hip score improved from 46.2±15.2 preoperatively to 90.3±5.3 postoperatively, and maintain 92.2±3.5 at the latest follow-up. The X-ray films showed bone ingrowths fixation in 20 hips (95%) and fibrous stable fixation in 1 hip (5%). The average stem subsidence was 2.4 mm (range, 0-10 mm). There were no re-revisions of the femoral stem for any reason. Conclusion The midterm results of revision total hip replacement with a fluted and tapered modular stem in Paprosky type Ⅱ, Ⅲ a, Ⅲ b femoral defect associated aseptic loosening of the femoral stem was encouraging.  相似文献   

8.
This study aimed to report the outcome of total hip arthroplasty (THA) with a modular femoral component in patients younger than fifty years with osteonecrosis of femoral head. Sixty-four osteonecrotic hips in fifty-five patients were available for clinical and radiographic analyses at minimum follow-up of fifteen-years. The mean Harris hip score improved from 36 points preoperatively to 92.7 points at final follow-up. Sixty-two (95.3%) hips demonstrated stable bone ingrowth. No hips showed loosening or required revision for aseptic loosening. Survivorship with an end point of stem revision for any reason was 93.8% and for aseptic loosening was 100% at 16.8 years. We believe that cementless THA with a modular stem is a promising procedure for young and active patients with osteonecrosis of the femoral head.  相似文献   

9.
We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%). After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component.  相似文献   

10.
11.
We evaluated the use of a stemmed acetabular component in the treatment of severe acetabular deficiency during revision and complex primary total hip arthroplasty. There were 31 hips of which 24 were revisions (20 for aseptic loosening, four for infection) and the remainder were complex primary arthroplasties. At a mean follow-up of 10.7 years (6 to 12.8), no component had been revised for aseptic loosening; one patient had undergone a revision of the polyethylene liner for wear. There was one failure because of infection. At the latest follow-up, the cumulative survival rate for aseptic loosening, with revision being the end-point, was 100%; for radiographic loosening it was 92% and for infection and radiographic loosening it was 88%. These results justify the continued use of this stemmed component for the reconstruction of severe acetabular deficiency.  相似文献   

12.
We report the results of 79 patients (81 hips) who underwent impaction grafting at revision hip replacement using the Exeter femoral stem. Their mean age was 64 years (31 to 83). According to the Endoklinik classification, 20 hips had a type 2 bone defect, 40 had type 3, and 21 had type 4. The mean follow-up for unrevised stems was 10.4 years (5 to 17). There were 12 re-operations due to intra- and post-operative fractures, infection (one hip) and aseptic loosening (one hip). All re-operations affected type 3 (6 hips) and 4 (6 hips) bone defects. The survival rate for re-operation for any cause was 100% for type 2, 81.2% (95% confidence interval (CI) 67.1 to 95.3) for type 3, and 70.8% (95% CI 51.1 to 90.5) for type 4 defects at 14 years. The survival rate with further revision for aseptic loosening as the end point was 98.6% (95% CI 95.8 to 100). The final clinical score was higher for patients with type 2 bone defects than type 4 regarding pain, function and range of movement. Limp was most frequent in the type 4 group (p < 0.001). The mean subsidence of the stem was 2.3 mm (SD 3.7) for hips with a type 2 defect, 4.3 mm (SD 7.2) for type 3 and 9.6 mm (SD 10.8) for type 4 (p = 0.022). The impacted bone grafting technique has good clinical results in femoral revision. However, major bone defects affect clinical outcome and also result in more operative complications.  相似文献   

13.
Mid-term results and migration behaviour of a ti-alloy cemented stem   总被引:3,自引:1,他引:2  
Between 1991 and 1994, 147 patients (154 hips) underwent a primary cemented total hip replacement using the Ultima ti-alloy, collarless, double-tapered stem and a UHMWPE cup. The average age at operation was 66.4 years. Ninety-one patients (97 hips) were available for review with an average follow-up of 76 months. The Harris hip score had improved from pre-operative average of 43.1 (12.5-65.0) to the latest score of 88.9 (67.5-100). There were 11 revisions in total, eight of which were for aseptic stem loosening. The results of Kaplan-Meier survival analysis, based on stem revision for aseptic loosening as an end-point, was 92% at 8 years. Early stem migration analysis at 2 years was possible in 114 cases using digitised radiographs analysed by the EBRA method. Sixty-three stems had not migrated and 35 migrated less than 2 mm with only one of these ending in failure. Sixteen stems showed early migration of more than 2 mm and five of these failed. Early stem migration is predictive of stem failure. Osteolytic lesions occurred in 12 femurs and four of these stems failed.  相似文献   

14.
BACKGROUND: We have been using hybrid total hip arthroplasty (a cementless acetabular component and a cemented stem) in young patients. The purpose of this study was to determine the prevalence of aseptic loosening, polyethylene wear, and osteolysis after the use of this technique. METHODS: We studied a prospective consecutive series of sixty-four primary hybrid total hip replacements in fifty-five patients younger than fifty years old. There were forty-three men and twelve women; the average age at the time of the index operation was 43.4 years. The average duration of follow-up was 9.4 years. We used a cementless acetabular component without screw-holes and a cemented femoral component with a 22-mm head in all hips. Clinical follow-up with use of Harris hip ratings and radiographic follow-up were performed at six weeks; at three, six, and twelve months; and yearly thereafter. The sequential annual linear and volumetric wear rates were measured, and bone-remodeling and osteolysis were assessed. RESULTS: The mean preoperative Harris hip score was 44 points, which increased to 95 points at the time of final follow-up. No hip had aseptic loosening. One hip (2%) was revised because of late infection. The average linear wear (and standard deviation) was 0.96 +/- 0.066 mm, with an average annual rate of 0.096 +/- 0.013 mm. The average volumetric wear was 364.7 +/- 25.2 mm (3), with an average annual rate of 43.4 +/- 3.5 mm (3). Six hips (9%) had an osteolytic lesion of <1 cm in diameter in the calcar femorale (zone 7). CONCLUSIONS: Our results show that a hybrid arthroplasty with a cementless acetabular component and a smooth cemented femoral component (Ra, 0.6 mm) is effective for primary total hip replacement in young patients. Although there was no aseptic loosening and a low prevalence of osteolysis at the latest follow-up evaluation, the high rates of linear and volumetric wear of the polyethylene liner in these young patients remain a concern.  相似文献   

15.
A higher-than-average rate of aseptic loosening has been postulated to be associated with the combination of a titanium stem and bone cement. In this prospective follow-up study we therefore investigated our first consecutive series of 250 implantations of a cemented femoral shaft prosthesis made of titanium alloy (BiCONTACT((R)), Aesculap, Tuttlingen, Germany).Average time of follow-up evaluation was 9.7 years (range 8.7-10.3 years). At follow-up, mean patient age was 81 years; 89 patients with 93 hips have deceased and two could not be located. Follow-up rate was 98.7% for the patients still alive at time of follow-up evaluation. Five patients have been revised, two for infection and one for aseptic loosening of a varus-malaligned stem; two radiologically well-fixed stems had been revised during acetabular revision. Survival estimate showed a calculated cumulative survival rate of 97.5% after 11 years [confidence limits: 99.0% (upper) and 94.1% (lower)]. The average Harris hip score at time of follow-up was 82.25 points.Radiologically, signs of loosening could be detected in 3 stems: in one case varus malalignement deteriorated with time and in 2 cases osteolyses developed together with significant polyethylene wear. All 3 patients experienced only mild pain and revision had not been indicated so far. In conclusion, the long-term follow-up results with this cemented titanium femoral component are encouraging and are comparable to other successful cemented femoral components in primary total hip arthroplasty. No increased risk for aseptical loosening was associated to the combination of titanium and cement in this specific stem. Design parameters seem to play an important role in the development of aseptic loosening in cemented titanium stems.  相似文献   

16.
We analyzed a consecutive series of 23 total hip arthroplasties that had been performed using modular cementless prostheses in 13 patients with a confirmed diagnosis of multiple epiphyseal dysplasia and end-stage osteoarthritis of the hip. The average Harris hip score improved from 40.6 to 93.8 points. Postoperatively, all hips demonstrated favorable alterations in the biomechanical parameters including hip center of rotation, femoral offset, femoral neck length, and limb length. At a mean follow-up of 4.8 years, no hip required revision because of aseptic loosening of the acetabular or femoral component. One patient (1 hip, 4.3%) underwent reoperation for polyethylene wear and osteolysis 8 years after index arthroplasty. This study shows encouraging clinical and radiographic outcomes of modular cementless total hip arthroplasties for this technically difficult condition.  相似文献   

17.
We evaluated the long-term results of cemented total hip arthroplasty with alumina ceramic heads in 39 patients (44 hips) from 1981 to 1985. The study comprised 8 men (8 hips) and 31 women (36 hips). Their mean age was 54 (37-76) years and mean weight 52 (34-93) kg. The preoperative diagnoses were osteoarthrosis in 34 patients (38 hips), rheumatoid arthritis in 3 (4 hips) and idiopathic osteonecrosis of the femoral head in 2 (2 hips). The mean duration of follow-up was 13 (10-16) years. At this time, 6 cases had been revised because of aseptic loosening (5 hips showed loosening of both components and 1 acetabular loosening alone). Kaplan-Meier survivorship analysis with radiographic loosening as end-point showed 10-year survival rates of 75% for the acetabular component and 86% for the femoral. The mean linear wear rate of polyethylene was 0.10 mm/year radiographically--i.e., about the same as reported for many metal to polyethylene bearings. 5 alumina ceramic heads were retrieved and showed excellent surface roughness and roundness without scratches. However, debris stuck to the gaps was detected. The debris may act as third-bodies and affect polyethylene wear.  相似文献   

18.
We evaluated the long-term results of cemented total hip arthroplasty with alumina ceramic heads in 39 patients (44 hips) from 1981 to 1985. The study comprised 8 men (8 hips) and 31 women (36 hips). Their mean age was 54 (37-76) years and mean weight 52 (34-93) kg. The preoperative diagnoses were osteoarthrosis in 34 patients (38 hips), rheumatoid arthritis in 3 (4 hips) and idiopathic osteonecrosis of the femoral head in 2 (2 hips). The mean duration of follow-up was 13 (10-16) years. At this time, 6 cases had been revised because of aseptic loosening (5 hips showed loosening of both components and 1 acetabular loosening alone). Kaplan-Meier survivorship analysis with radiographic loosening as end-point showed 10-year survival rates of 75% for the acetabular component and 86% for the femoral. The mean linear wear rate of polyethylene was 0.10 mm/year radiographically--i.e., about the same as reported for many metal to polyethylene bearings. 5 alumina ceramic heads were retrieved and showed excellent surface roughness and roundness without scratches. However, debris stuck to the gaps was detected. The debris may act as third-bodies and affect polyethylene wear.  相似文献   

19.
We evaluated the long-term results of cemented total hip arthroplasty with alumina ceramic heads in 39 patients (44 hips) from 1981 to 1985. The study comprised 8 men (8 hips) and 31 women (36 hips). Their mean age was 54 (37-76) years and mean weight 52 (34-93) kg. The preoperative diagnoses were osteoarthrosis in 34 patients (38 hips), rheumatoid arthritis in 3 (4 hips) and idiopathic osteonecrosis of the femoral head in 2 (2 hips). The mean duration of follow-up was 13 (10-16) years. At this time, 6 cases had been revised because of aseptic loosening (5 hips showed loosening of both components and 1 acetabular loosening alone). Kaplan-Meier survivorship analysis with radiographic loosening as end-point showed 10-year survival rates of 75% for the acetabular component and 86% for the femoral. The mean linear wear rate of polyethylene was 0.10 mm/year radiographically--i.e., about the same as reported for many metal to polyethylene bearings. 5 alumina ceramic heads were retrieved and showed excellent surface roughness and roundness without scratches. However, debris stuck to the gaps was detected. The debris may act as third-bodies and affect polyethylene wear.  相似文献   

20.
Introduction Inferior survival of cemented total hip arthroplasty has been reported after previous femoral osteotomy. The purpose of this study was to evaluate the long-term survival of uncemented stems after femoral osteotomy.Materials and methods Forty-eight hips in 45 patients had undergone conversion THA for a failed intertrochanteric osteotomy of the hip after a mean of 12 years (2–33 years). Mean time of follow-up was 11 years (5–15 years).Results At follow-up, two patients (three hips) had died, and one patient (one hip) was not located. Three patients (three hips) underwent femoral revision—one for infection and two for aseptic loosening of the stem. Survival of the stem was 94% at 10 years, and survival with femoral revision for aseptic loosening as an end point was 96%. The median Harris Hip Score at follow-up was 80 points. Radiolucent lines in Gruen zones 1 and 7 were present in 14 and 18% of hips, respectively. Radiolucencies in other zones were not detected. There was no radiographic evidence of femoral osteolysis, stress-shielding or loosening.Conclusion The results with this type of uncemented tapered titanium femoral component after proximal femoral osteotomy are encouraging and compare to those achieved in patients with regular femoral anatomy.  相似文献   