首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.

Purpose

The purpose of this study was to assess the clinical and radiographic results of a total hip arthroplasty with the double tapered Mallory-Head system.

Methods

The clinical and radiographic results of a consecutive series of 81 total hip replacements in 75 patients were reviewed 10–15?years (average 11.4?years) postoperatively. The patients’ underlying conditions were avascular necrosis in 46 hips (57?%), osteoarthritis in 12 hips (15?%), RA in nine hips (11?%), and others. Clinical results were evaluated based on the modified Harris hip score and modified Merle d’Aubigné-Postel score. A radiographic analysis was performed.

Results

The average modified Harris hip score improved from a preoperative score of 56 points to a postoperative 92 points. The average modified Merle d’Aubigné-Postel score was 15 points at the latest follow up, and 55 hips (68?%) were classified as the clinical grades of excellent or good results. One acetabular component was revised because of loosening, and one was revised for recurrent dislocation.

Conclusion

The clinical and radiological evaluations of the total hip replacements using the Mallory-Head system showed good results.  相似文献   

3.

Background

Metal ion levels are used as a surrogate marker for wear in hip resurfacing arthroplasties. Improper component position, particularly on the acetabular side, plays an important role in problems with the bearing surfaces, such as edge loading, impingement on the acetabular component rim, lack of fluid-film lubrication, and acetabular component deformation. There are little data regarding femoral component position and its possible implications on wear and failure rates. The purpose of this investigation was to determine both femoral and acetabular component positions in our cohort of mechanically stable hip resurfacing arthroplasties and to determine if these were related to metal ion levels.

Methods

One hundred fourteen patients who had undergone a computer-assisted metal-on-metal hip resurfacing were prospectively followed. Cobalt and chromium levels, Harris Hip, and UCLA activity scores in addition to measures of the acetabular and femoral component position and angles of the femur and acetabulum were recorded.

Results

Significant changes included increases in the position of the acetabular component compared to the native acetabulum; increase in femoral vertical offset; and decreases in global offset, gluteus medius activation angle, and abductor arm angle (P < .05). Multiple regression analysis found no significant predictors of cobalt and chromium metal ion levels.

Conclusion

Femoral and acetabular components placed in acceptable position failed to predict increased metal ion levels, and increased levels did not adversely impact patient function or satisfaction. Further research is necessary to clarify factors contributing to prosthesis wear.  相似文献   

4.

Purpose

Concerns have been raised in relation to metal-on-metal (MoM) articulations with catastrophic soft-tissue reactions due to metal debris. We reviewed how small head MoM articulations perform in primary uncemented total hip arthroplasty (THA) in young patients at a minimum of ten years.

Methods

We retrospectively evaluated the clinical and radiographic results of the first 100 consecutive primary cementless THAs using the 28-mm Metasul MoM articulation in 91 patients younger than 50 years of age at the time of surgery.

Results

After 13 years, survival for the endpoint revision due to any reason was 90.9 % and 98.9 % for revision due to aseptic implant loosening. The cumulative incidence of MoM related revisions was 1.2 %. Small proximal femoral osteolysis was found in 18 % of hips. No acetabular osteolysis or loosening was detected. Two hips showed signs of femoral neck impingement with severe damage to the neck.

Conclusions

Early in the second decade, MoM-associated complications were rare using the 28-mm Metasul articulation, and aseptic loosening was not a major mode of failure in this cohort of young patients.

Level of evidence

Therapeutic Level IV.  相似文献   

5.

Purpose

The purpose of this study was to evaluate our clinical experience with ceramic-on-ceramic cementless total hip arthroplasty (THA) and complications after an average follow-up of more than eight years.

Methods

From January 2001 to December 2008, 540 THA with ceramic-on-ceramic bearings were performed in 448 patients (92 bilateral, 54 of which were operated simultaneously) with a mean age 49.9 years (range 18–84) by a senior surgeon. Pre-operative aetiological reasons were developmental dysplasia of the hip (DDH) in 205 hips, degenerative arthritis in 157 hips, avascular necrosis in 51 hips, rheumatoid diseases in 40 hips, posttraumatic arthritis in 40 hips, other reasons in 25 hips and revision surgery in 22 hips. Patients were evaluated with Harris hip score (HSS), and radiological findings of acetabular and femoral component loosening or osteolysis with ceramic bearing related complications like squeaking, liner and head fractures were recorded.

Result

The average duration of follow-up time was 8.2 years (range, five to 13.2). The main Harris hip score increased from 42.4 points preoperatively to 94.9 points at the time of last follow-up. We had one fracture of the ceramic head, 11 clicking and four squeaking; one of them was revised because of terrible squeaking due to acetabular liner fracture, the other three were seldom audible from the outside and followed conservatively. We did not observed loosening or osteolysis due to ceramic bearings at the time of the final follow-up.

Conclusion

Our study has demonstrated that ceramic-on-ceramic bearings can be used safely in different etiological problems. Incidences of noisy hips are becoming less frequent.  相似文献   

6.

Purpose

Bipolar hemiarthroplasty (BHA) for idiopathic osteonecrosis of the femoral head (ONFH) is performed at our institution. The purpose of this study was to evaluate the clinical and radiographic findings after BHA for the treatment of steroid -induced ONFH.

Methods

Thirty-seven hips in 27 patients were assessed (seven men, 11 hips; 20 women, 26 hips), average patient age at the time of surgery of 42.6?(range 20–83)?years, with steroid-induced ONFH treated with BHA between 1995 and 2005. The mean follow-up duration was approximately ten?(range five to15)?years. Patients were evaluated according to the Japan Orthopaedic Association (JOA) hip score. Kaplan–Meier survivorship was calculated to examine revision arthroplasty failure rate. Radiographic analysis of loosening included radiolucent lines and osteolysis of the acetabulum or femur. Causes of loosening were analysed using multiple logistic regression.

Result

JOA hip score increased from 53 points (preoperative) to 87 points (final follow-up). Survival rates were 96.8?% and 78.6?% at ten and 15?years, respectively. Prosthesis loosening occurred on the acetabular side in five hips (13.5?%). No femoral-component loosening was observed. BHA had poor results in patients with Association Research Circulation Osseous (ARCO) stage IV ONFH and in patients under 40?years of age.

Conclusion

BHA, with strict surgical indications, may be a good option for treating ONFH. Based on these results, total hip arthroplasty is recommended for patients with ARCO stage IV ONFH or for patients under 40?years of age.  相似文献   

7.

Purpose

The aim of the study was to assess bone graft incorporation after revision hip arthroplasty in patients with rheumatoid arthritis (RA).

Methods

We report an acetabular reconstruction using impacted, morselized, frozen, radiation sterilized bone allografts in 71 patients suffering from RA. There were sixty-six women and five men at a mean age of 57.5 years. Reconstruction was performed in 78 revision total hip arthroplasties (THAs) for aseptic loosening of acetabular component. The mean follow-up was five years and four months. In 38 cases, a revision was done with use of reinforcement devices.

Results

In four revised hips (10 %) without reinforcement implants, resorption of the allografts was noticed. All Mueller rings and 50 % of unscrews cages (Link, Howmedica) were revised because of aseptic loosening and bone graft resorption. In all of 17 hips with the Burch-Schneider cage, no measurable migration or bone allografts resorption occurred. There were no major general complications.

Conclusions

Acetabular reconstruction with use of morselized, frozen, radiation sterilized bone allografts and the Burch-Schneider cage can be highly successful in managing massive deficiency of acetabular bone stock in revision hip arthroplasty in RA patients.  相似文献   

8.

Background

The preoperative bone defect and the reconstruction of the center of rotation of the hip are critical in acetabular revision surgery. Uncemented oblong cups are employed in order to manage these issues. We analyzed the clinical results and rates of revision of two different uncemented oblong cups, the reconstruction of the center of rotation of the hip, as well as the rate of radiological loosening and possible risk factors.

Materials and methods

Forty-five patients (46 hips) underwent acetabular revision surgery using two different uncemented oblong cups. We assessed the clinical results and the survival rate for revision and aseptic loosening. Intraoperative bone loss was classified according to Paprosky, and acetabular reconstruction was assessed according to Ranawat. The mean follow-up was 7.2 years (range 4–11 years).

Results

There were four re-revisions (three due to aseptic loosening); the survival rate for re-revision due to aseptic loosening was 60.1 % at seven years. The mean distance between the center of the femoral head prosthesis and the approximate center of the femoral head improved from 21.5 to 10.2 mm. Thirteen cups showed radiological loosening; the survival rate for radiological loosening at seven years was 40.54 %. A smaller postoperative horizontal distance was correlated with cup loosening.

Conclusions

Although optimal acetabular reconstruction can be achieved by using oblong uncemented cups in revision hip surgery, the clinical and radiological results are not encouraging. Excessive medialization of the cup may increase the rate of loosening.  相似文献   

9.
We present the 20-year experience of 47 hips in 40 patients aged 50 years or younger with cemented primary total hip arthroplasty using second-generation femoral cementing techniques. Average follow-up duration in the 23 patients living at least 17 years was 18.2 years. Overall, 18 hips (38%) had components revised or removed for any reason, at an average duration of 12.6 years. Every revision or reoperation involved removing the acetabular component. Of these 18 acetabular components, 15 (32%) were revised for aseptic loosening. Eleven additional acetabular components were loose by radiographic criteria at final follow-up, yielding prevalence of aseptic acetabular loosening (55%). Four femoral components (8%) were revised for osteolysis without loosening, and 3 (6%) were revised for aseptic loosening. Femoral osteolysis, with or without component loosening, led to revision in 5 ( 11%) hips compared with 6% for aseptic loosening alone. Osteolysis was the primary problem leading to acetabular and femoral component revision in this series of people < or = 50 years old over the first 20 years after the index operation.  相似文献   

10.
11.

Background

Women seeking surgical intervention for their hip disorders will often find total hip arthroplasty (THA) presented as their only option. THA, when compared with hip resurfacing arthroplasty, removes substantially more bone-stock, limits range-of-motion, exhibits increased dislocation risk, and presents greater overall 10-year mortality rate. Despite these risks, most surgeons continue to select against women for hip resurfacing because registries notoriously report inferior survivorship when compared with men and THA.

Methods

We investigated the reasons for why resurfacing arthroplasty devices survive poorly in women to develop interventions which might improve hip resurfacing outcomes in women. Using these findings, we developed a series of surgical interventions to treat the underlying issues. Herein, we compare 2 study groups: women who received hip resurfacings before (group 1) and after (group 2) these interventions.

Results

Eight-year implant survivorship substantially improved from 89.6% for group 1 to 97.7% for group 2. Adverse wear-related failure, femoral component loosening, and acetabular component loosening were all significantly reduced in group 2, which we attribute to the implementation of our relative acetabular inclination limit guidelines, use of uncemented femoral fixation, and selection of the Tri-Spike acetabular component for supplemental fixation, respectively. Kaplan-Meier implant survivorship curves, grouped into 2-year time intervals, show that the disparity in failure rates between men and women is diminishing.

Conclusion

When experienced surgeons use refined and proper surgical technique, women show promise as excellent candidates for hip resurfacing as an alternative treatment for their debilitating hip conditions.  相似文献   

12.

Background

There are relatively few 20-year results of uncemented acetabular components, and most of these are modular designs. This study reports the 20-year results of a monoblock press-fit acetabular component.

Methods

A total of 122 total hip arthroplasties (111 patients) using the Morscher cup were reviewed at a mean of 19.7 years. The average age at implantation was 57.3 years (range, 36-74 years), and 81 (66%) were men.

Results

Twenty-two patients (25 hips) had died. Seven hips were revised, including 5 acetabular revisions. Six patients (6 hips) declined to participate but were known not to have been revised. The mean Oxford hip score was 41.1 (range, 22-48), and the mean reduced Western Ontario and McMaster Universities Osteoarthritis Index score was 5.7/48 (range, 0-24). Eccentric wear was seen in 13 (15.7%) and major osteolysis in 14 (17%) of 82 surviving hips with radiographs. The all-cause revision rate was 0.32 per 100 observed component years (95% confidence interval [CI], 0.13-0.66). The 20-year Kaplan-Meier survival was 93.4% (CI, 86.6-96.8) for all-cause revisions, 95.5% (CI, 89.4-98.1) for any acetabular revision, and 97.1% (CI, 91.2-99.1) for acetabular aseptic loosening, wear, or osteolysis.

Conclusion

The Morscher acetabular component has continued to perform well at 20 years despite using conventional polyethylene with results that match or surpass other cementless acetabulae.  相似文献   

13.

Introduction

A flattened cup was designed to create a more physiological load transfer to the pelvic bone compared to hemispherical cups, and to allow more bone contact compared to low-profile’ spherical cups. To investigate these theoretical advantages and the potential influence of the quality of the acetabular bone, a clinical study was performed in patients with osteoarthritis (OA) and inflammatory arthritis (IA). The aims of the study were (1) to evaluate the fixation of the cup, postoperatively and later when osseous integration should have taken place, (2) to assess perioperative complications such as acetabular fractures and (3) to monitor the polar gap, a potential risk factor for osteolysis.

Patients and methods

A prospective study was performed on all consecutive OA and IA patients with an indication for primary total hip arthroplasty (THA). Three hundred and nine OA patients (340 hips) and 65 IA patients (76 hips) were included. The acetabular component was the flattened press-fit EPF-PLUS® cup, the femoral component the tapered cementless Zweymueller SL-PLUS® stem. All revisions and complications were recorded. Clinical and radiographical evaluation was performed on regular basis during 6–10 years.

Results

The incidence of early loosening of the cup was 0 out of 340 in the OA group and 1 out of 76 in the IA group. The incidence of acetabular fractures was 7 out of 340 in the OA group and 3 out of 76 in the IA group. Failure rate for the acetabular component due to aseptic loosening or osteolysis after 6–10 years was 0% in the OA group and 4.8% in the IA group. In all cases available for follow-up the polar gap had disappeared and full osseous integration had taken place in both the groups.

Interpretation

This study shows that the flattened press-fit acetabular component creates adequate initial mechanical stability to allow osseous integration and that the cup can be safely used in both OA and IA patients. However, after 6–10 years, in the IA group failure of the cup due to aseptic loosening occurred once and failure due to osteolysis occurred three times, while these type of failures did not occur in the OA group.  相似文献   

14.

Purpose

Hip resurfacing arthroplasty (HRA) is a technically demanding operation, requiring both accuracy and precision in placement of the acetabular and femoral components. Malalignment of the component can lead to notching and possible femoral neck fractures. We used specific templates created using a rapid prototyping machine based on the patients’ anatomy, to aid in accurate intraoperative pin placement.

Methods

A 3D model of the hip was reconstructed using spiral computed tomography (CT) data by Amira 3.1 software in 16 patients in whom HRA was planned for hip osteoarthritis (OA). All of the patients in the study had normal contralateral hips. The rotational centre of femoral head on the normal side was superimposed using Imageware12.0 software to determine the centre of the femoral head on the contralateral side. The data was then used to produce patient-specific templates using a rapid prototyping technique. These templates were designed according to the anatomical features of femoral head surface, the rotation centre and the planned prosthesis shaft angle. The orientation of the prosthesis was determined by matching the model to the femoral head surface during the operation. In addition, a control group of 18 patients with OA was operated upon by the conventional method.

Results

The mean prosthesis stem shaft angle (SSA), as determined from postoperative imaging, was 138.68?±?8.85° for the locating template group, and (118.9?±?12.8) for the conventional group.

Conclusions

The locating template designed and constructed preoperatively can provide precise and dependable location for hip resurfacing femoral components during arthroplasty and ensure the valgus stem placement necessary for optimal outcomes.  相似文献   

15.

Purpose

Whilst excellent long-term results with contemporary uncemented stems have been reported for total hip arthroplasty in young patients, the survival rates for the whole reconstruction are often compromised by high failure rates on the acetabular site due to peri-acetabular osteolysis and accelerated wear.

Methods

In patients 60 years old or younger, we retrospectively reviewed the results at a minimum of ten years of 89 consecutive uncemented total hip replacements in 88 patients using the press-fit Fitmore acetabular component in combination with the CLS Spotorno stem and a 28-mm Metasul metal-on-metal articulation or a 28-mm alumina ceramic on conventional polyethylene bearing. The mean age at the time of surgery was 49 years (range, 25–60). The mean clinical and radiological follow-up was 12 years (range, 10–15).

Results

Six patients (six hips) died and two patients (two hips) were lost to follow-up. Five hips were revised: one for deep infection, one for peri-prosthetic femoral fracture, and one for aseptic stem loosening. In two hips an isolated revision of the acetabular liner was performed (one for recurrent dislocation and one for unexplained pain). No revision was performed for accelerated wear, osteolysis or aseptic loosening of the acetabular shell. We could not detect peri-acetabular osteolysis visible on plain radiographs in those hips evaluated radiographically. The Kaplan-Meier survival with revision for any reason as the endpoint was 94% (95% confidence interval, 86–97) at 12 years.

Conclusions

The survival rates and the radiological outcomes with this implant combination in this young and active patient group are encouraging when compared to the results reported for other uncemented cups in this age group.  相似文献   

16.
Despite the increasing interest and subsequent published literature on hip resurfacing arthroplasty, little is known about the prevalence of its complications and in particular the less common modes of failure. The aim of this study was to identify the prevalence of failure of hip resurfacing arthroplasty and to analyse the reasons for it. From a multi-surgeon series (141 surgeons) of 5000 Birmingham hip resurfacings we have analysed the modes, prevalence, gender differences and times to failure of any hip requiring revision. To date 182 hips have been revised (3.6%). The most common cause for revision was a fracture of the neck of the femur (54 hips, prevalence 1.1%), followed by loosening of the acetabular component (32 hips, 0.6%), collapse of the femoral head/avascular necrosis (30 hips, 0.6%), loosening of the femoral component (19 hips, 0.4%), infection (17 hips, 0.3%), pain with aseptic lymphocytic vascular and associated lesions (ALVAL)/metallosis (15 hips, 0.3%), loosening of both components (five hips, 0.1%), dislocation (five hips, 0.1%) and malposition of the acetabular component (three hips, 0.1%). In two cases the cause of failure was unknown. Comparing men with women, we found the prevalence of revision to be significantly higher in women (women = 5.7%; men = 2.6%, p < 0.001). When analysing the individual modes of failure women had significantly more revisions for loosening of the acetabular component, dislocation, infection and pain/ALVAL/metallosis (p < 0.001, p = 0.004, p = 0.008, p = 0.01 respectively). The mean time to failure was 2.9 years (0.003 to 11.0) for all causes, with revision for fracture of the neck of the femur occurring earlier than other causes (mean 1.5 years, 0.02 to 11.0). There was a significantly shorter time to failure in men (mean 2.1 years, 0.4 to 8.7) compared with women (mean 3.6 years, 0.003 to 11.0) (p < 0.001).  相似文献   

17.

Purpose

Modular acetabular reconstructive cups have been introduced in an attempt to offer initial rigid fixation by iliac lag screws and ischial pegs, to support bone grafts with a flanged metal socket, and to restore original hip center in acetabular revision. The purpose of this study was to clarify minimum ten year follow-up results of this cup system with morsellised allografts in revision cases.

Methods

We retrospectively investigated 54 acetabular revisions at a mean of 11 years (range, ten to 14 years). The indications were Paprosky’s type 2B (eight hip), 2C (eight hips), 3A (23 hips), 3B (nine hips), and 4 (six hips).

Results

Using aseptic loosening as the endpoints, the survival rate was 89.3 % (95 % CI 81–98). Radiographically, one type 3A hip, three type 3B hips and one type 4 hip showed aseptic loosening while no type 2 hips or no cemented cups showed loosening.

Conclusions

The modular reconstructive cups for acetabular revision showed bone stock restoration and stable implantation.  相似文献   

18.

Purpose

The Reflection® second-generation uncemented acetabular component was designed to address increased rates of failure observed with the early acetabular designs. However, the reported survivorship of this acetabular component has been conflicting. The aim of this study was to describe the ten to 15-year survivorship and polyethylene wear rate for the uncemented Reflection® acetabular component performed as part of a primary total hip replacement.

Methods

One hundred and four consecutive Reflection® uncemented acetabular components in 97 patients were identified from a prospective arthroplasty database with a minimum of ten years of follow-up. No patient was lost to follow-up. Mean cohort age was 59.1 years.

Results

There were 24 revisions of the acetabular component. The all-cause survival rate at ten years was 77.2 % [95 % confidence interval (CI) 73.9–80.5]. Mean linear wear was 0.20 mm [standard deviation (SD) 0.08] per year and the volumetric wear was 106.2 mm3 per year. At final follow-up, more than half the patients had osteolysis identified around the femoral component. The mean Oxford Hip Score was 35.6 (SD 9.8) at a mean follow-up of 11.9 years, with six (11.1 %) excellent, 26 (48.1 %) good, 17 (31.5 %) fair and five (9.3 %) poor outcomes. Despite the fact that more than a third had a fair or poor outcome, only four (7.4 %) were not satisfied with their hip.

Conclusions

Due to the high rate of relatively asymptomatic polyethylene wear and osteolysis associated with this acetabular component, in our department, we now review all surviving patients both clinically and radiographically on an annual basis.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号