首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background and purpose

Evaluation of bone marrow infiltration is an essential step in the staging of lymphoma. The accuracy of 18F-fluorodeoxyglucose-positron emission tomography (18F-FDG PET), combined 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) and magnetic resonance imaging (MRI) in diagnosing bone marrow involvement of lymphoma has never been systematically assessed, and the present systematic review was aimed at this issue.

Methods

MEDLINE, EMBASE, Cochrane library and some other databases, from January 1995 to July 2010, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of 18F-FDG PET, PET/CT and MRI for patients with bone marrow involvement of lymphoma were collected. We extracted data to calculate sensitivity, specificity, SROC curves and AUC and to test for heterogeneity. The statistic software called “Meta-Disc 1.4” was used for data analysis.

Result

In 32 included studies, PET/CT had the highest pooled sensitivity, 91.6% (95%CI: 85.1, 95.9) and highest pooled specificity, 90.3% (95%CI: 85.9, 93.7). PET/CT also had the highest pooled DOR, 68.89 (95%CI: 15.88, 298.92). The AUC of PET, PET/CT, and MRI were 0.9430, 0.9505 and 0.8764. There was heterogeneity among studies and no evidence of publication bias.

Conclusion

PET/CT was a highly sensitive and specific modality in diagnosing patients with bone marrow involvement in lymphoma. Compared with MRI and PET alone, PET/CT can play important roles in the staging of lymphoma.  相似文献   

2.

Objective

To assess the use of positron emission tomography (PET)/computed tomography (CT) in patients with suspected ovarian cancer recurrence and describe the distribution of metastasis.

Patients and methods

This study included (39) patients suspected to have recurrent ovarian malignancy. This suspicion was either clinically, radiologically or due to raised CA-125 levels. All patients underwent 18F-FDG PET/CT, surgery was performed within 8 weeks of imaging studies. Surgical and/or histopathological examinations were available in 31 patients, and clinical, radiological and CA 125 serum level follow up in 8 patients.

Results

The overall lesion-based sensitivity, specificity, and accuracy of PET/CT for revealing recurrent ovarian carcinoma were 90%, 98% and 97%, respectively. The patient – based sensitivity, specificity, and accuracy of PET/CT were 97%, 75% and 95%, respectively.

Conclusion

18F-FDG PET/CT is a useful tool for evaluating the recurrence of ovarian cancer after first-line therapy in patients with a high risk of relapse, equivocal radiologic findings, increased or normal levels of serum CA-125. It can more accurately diagnose and localize recurrence, hence decreasing the rate of second look surgery and changing treatment plan.  相似文献   

3.

Purpose

To estimate the accuracy of 18FDG PET/CT in detection of recurrent cancer ovary and to describe the localization of metastases for restaging.

Materials and methods

44 female patients with suspicion of ovarian cancer recurrence underwent a PET/CT scan from September 2013 to August 2015.

Results

CA-125 levels were elevated in 36 patients, 25 patients presented with alterations on imaging and 18 patients had clinical suspicion of recurrence. Imaging examinations were normal in 10/36 patients with elevated CA-125. 18FDG PET/CT scan was positive in 39/44 patients, and it was negative in 5/44 patients, 4/5 patients continued to be disease free all over the follow-up (true negative), while PET-CT missed recurrence in 1/5 patient (false negative). 1/39 patient was false positive. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of integrated PET/CT were calculated to be 91%, 76%, 96%, 50% and 87%.

Conclusion

18FDG PET/CT is an accurate modality for detection of recurrence of ovarian cancer. The accuracy of PET–CT in precise localization of suspicious FDG uptake can lead to proper assessment of disease recurrence, thus allow for restaging of the disease and subsequently optimizing treatment plan for these patients.  相似文献   

4.

Objectives

To review the published data in literature on patients affected by gynaecological malignancies to establish the role of 18F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI).

Materials and methods

All papers specifically addressed to the role of 18F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study.

Results and conclusions

The use of 18F-FDG PET, and even more of 18F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that 18F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of 18F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of 18F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.  相似文献   

5.

Introduction

Silicone breast implants are widely used for breast augmentation and breast reconstruction following mastectomy. Implant rupture has specific radiological signs. With the advent use of new imaging technique such as positron emission tomography (PET) computed tomography (CT) and magnetic resonance imaging (MRI) of the breast, these signs may simulate malignancy.

Patients and methods

We retrospectively reviewed four cases of patients with silicon breast implants who arrive to the mammography clinic for further evaluation of a suspected malignant process demonstrated on either PET CT or breast MRI.

Results

Two cases were of PET CT performed for routine oncology follow-up of breast cancer. On both, the PET CT demonstrated multiple-spread benign silicone granulomas manifesting as multiple masses having an increase fluorodeoxyglucose (FDG) uptake. One case of a new mass was demonstrated as a suspicious mass on the dynamic sequences on MRI of the breast. Ultrasound-guided biopsy demonstrated benign tissue response to silicone. One case demonstrated bilateral ruptured breast implants on breast MRI, as well as bilateral axillary and mediastinal lymphadenopathy. Eventually, the patient underwent bronchoscopy for pulmonary workup of dry cough, revealing sarcoidosis.

Conclusion

Silicone granulomas can manifest as masses with suspicious morphology and enhancement dynamics on breast MRI or with increased FDG uptake on PET CT. The presence of silicone implants and awareness of the possibility of a rupture and formation of silicone granulomas may help in facilitating a correct diagnosis.  相似文献   

6.

Purpose

To retrospectively review CT and MRI findings in a series of six intraspinal primitive neuroectoderal tumors and to find out their radiological features.

Methods

CT and MRI of six patients with surgically and pathologically proved intraspinal primitive neuroectoderal tumor were retrospectively reviewed. The tumor location, morphological features, signal intensity, calcification, contrast enhancement characteristics, involvement of paraspinal soft tissues and adjacent bony structures were assessed.

Results

Of six patients, four had extradural lesions and two had intradural, extramedullary lesions. Most lesions were well defined and manifested heterogeneous iso- or hypo-intense signal on T1-weighted imaging and hyper-intense signal on T2-weighted imaging and moderate attenuation on CT, and were heterogeneously enhanced after contrast enhancement. The lesion extending through the intervertebral foramen with a large paraspinal soft tissue mass formed was found in four patients and vertebral bone involvement was seen in four patients.

Conclusions

Although imaging findings are not specific of intraspinal primitive neuroectoderal tumor, this diagnosis could be suggested when MR imaging depicts an intradural, extramedullary or extradural large well-circumscribed mass which extends out from intervertebral foramen and invades paraspinal soft tissues or vertebral bones in a young patient.  相似文献   

7.

Objective

The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer.

Methods

Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging.

Results

Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET.

Conclusion

Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.  相似文献   

8.

Purpose

To assess the clinical value of retrospective image fusion of neck MRI and 18F-fluorodeoxyglucose (18F-FDG) PET for locoregional extension and nodal staging of neck cancer.

Materials and methods

Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated.

Results

Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant.

Conclusion

Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer.  相似文献   

9.

Objective

To characterize the radiographic findings of pediatric patients with severe Influenza-A (H1N1) disease.

Methods

A retrospective study of data from chest X-ray, CT and MRI exam of 29 pediatric patients treated in intensive care unit for severe Influenza-A (H1N1) disease.

Results

Disease developed quickly at early stage. Here are four types of radiographic findings. The disease continued to progress for 2-3 days and X-ray showed that all 29 patients had increased solid lesions with the existence of interstitial lesions. Four days later, all lung lesions showed absorption to certain degree. Fifteen days later, X-ray and CT showed complete or significant absorption in 19 cases (85.5%); delayed recovery was identified in 8 cases (27.6%), pulmonary fibrosis was found in 3 cases (10.3%), and 3 patients (10.3%) died. But the latter identified more lesions. Cranial CT and MRI were performed for 8 patients who had neurological symptoms. Of them, 3 cases (10.3%) were abnormal, showed symmetrical long T1 and T2 signal shadow in bilateral thalamus and longer T1 and T2 signals in the between. 3 cases had autopsy completed.

Conclusion

The severe Influenza-A (H1N1) among children progression was generally rapid in the first 3 days. The overall radiographic findings are similar to acute respiratory distress syndrome (ARDS). A small portion of the patients occurred acute necrotizing encephalopathy and plastic bronchitis.  相似文献   

10.

Purpose

To evaluate the performance of F-18 FDG PET/CT in the detection of bone metastasis in non-small cell lung cancer (NSCLC) patients.

Materials and methods

Three hundred and sixty-two consecutive NSCLC patients who underwent F-18 FDG PET/CT scanning were retrospectively analyzed. Each image of PET/CT, combined CT, and PET was performed at 10 separate areas and interpreted blindly and separately. The sensitivity, specificity and accuracy of F-18 FDG PET/CT, combined CT and F-18 FDG PET were calculated and the results were statistically analyzed.

Results

Bone metastasis was confirmed in 82 patients with 331 positive segments based on the image findings and clinical follow-up. On patient-based analysis, the sensitivity of F-18 FDG PET/CT (93.9%) was significantly higher than those of combined CT (74.4%) and F-18 FDG PET (84.1%), respectively (p < 0.05). The overall specificity and accuracy of combined CT, F-18 FDG PET, and F-18 FDG PET/CT were 90.7%, 93.2%, 98.9% and 87.0%, 91.2%, and 97.8%, respectively (compared with PET/CT, p < 0.05). On segment-based analysis, the sensitivity of the three modalities were 79.5%, 94.3%, and 98.8%, respectively (compared with PET/CT, p < 0.05). The overall specificity and accuracy of the three modalities were 87.9%, 89.2%, 98.6% and 84.5%, 91.2%, 98.7%, respectively (compared with PET/CT, p < 0.05).

Conclusion

F-18 FDG PET/CT is superior to F-18 FDG PET or combined CT in detecting bone metastasis of NSCLC patients because of the complementation of CT and PET. It is worth noting that the added value of F-18 FDG PET/CT may beneficially impact the clinical management of NSCLC.  相似文献   

11.

Objective

To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated 18F-fluorodeoxyglucose (FDG)-PET/CT studies for restaging of ovarian cancer.

Materials and methods

One hundred and twenty women who had undergone treatment for ovarian cancer underwent a conventional PET/CT scans with ldCT, and then ceCT. Two observers interpreted and decided in consensus on the PET/ldCT and PET/ceCT images by a 3-point scale (N: negative, E: equivocal, P: positive) per patient and lesion site. Final diagnoses were obtained by histopathological examinations, or clinical follow-up for at least 6 months.

Results

Patient-based analysis showed that the sensitivity, specificity, and accuracy of PET/ceCT was 86.9% (40/46), 95.9% (71/74), and 92.5% (111/120), respectively, whereas those of PET/ldCT were 78.3% (36/46), 95.0% (70/74), and 88.3% (106/120), respectively. All sensitivity, specificity, and accuracy significantly differed between two methods (McNemar test, p < 0.0005, p = 0.023, and p < 0.0001, respectively). The scales of detecting 104 recurrent lesion sites were N:14, E:6, P:84 for PET/ceCT, and N:15, E:17, P:72 for PET/ldCT, respectively. Eleven equivocal and one negative regions by PET/ldCT were correctly interpreted as positive by PET/ceCT.

Conclusion

PET/ceCT is a more accurate imaging modality with higher confidence for assessing ovarian cancer recurrence than PET/ldCT.  相似文献   

12.

Purpose

To evaluate the diagnostic impact of MRI or/and multidetector CT in young patients with wrist injury and inconclusive or negative clinical examination and X-rays and to analyze variations in imaging strategies between a district general hospital (GH) and a university hospital (UH).

Materials and methods

A retrospective analysis of 34 young patients (mean age 23 years) with wrist trauma who underwent CT or/and MRI was performed. The injury was acute in 24, and chronic in 10 patients. Twenty-two patients were from a GH and 12 from a UH. Two experienced musculoskeletal radiologists blindly reviewed the imaging studies. The effect of cross-sectional imaging on patient care and treatment plan was evaluated.

Results

In 9 of 34 patients one or more fractures were diagnosed on cross-sectional imaging. The scaphoid was fractured in four patients, the lunate and/or the trapezium in three patients, the scaphoid together with the lunate in one patient, and finally the distal radius in one patient. Ligamentous trauma was identified solely on MRI in 11 patients (involving the TFCC in eight cases). In four patients with both imaging methods, CT revealed one fracture of the trapezium not seen on MRI, and one scapholunate fracture with MRI findings of distal radial fracture only. In two patients with normal CT, MRI revealed bone marrow oedema of the scaphoid in one and of the distal radius, lunate and triquetrum in the other.

Conclusion

Both CT and MRI might be considered in patients with acute or chronic wrist injury, clinical dilemma and normal initial radiographs, depending on the availability and the individual institution policies.  相似文献   

13.

Aim

Positron emission tomography (PET) using F18-flurodeoxy-glucose (FDG) has been widely used for reflecting cellular metabolism. However, the feasibility of FDG PET in the diagnosis of hepatocellular carcinoma (HCC) is limited. The aim of the study was to assess the ability of FDG PET (PET/CT) in the detection of extrahepatic metastases or recurrent HCC.

Materials and methods

We conducted MEDLINE, EMBASE and COCHRANE searches (last update, April 2011). Eight eligible articles were identified evaluating F18-FDG PET (PET/CT) in extrahepatic metastases or recurrent HCC. Two authors independently evaluated the methodological quality of each study. We estimated pooled sensitivities, specificities, summary receiver-operating-characteristic (SROC) curves, and summary likelihood ratios.

Results

Eight eligible studies were enrolled in this study. The pooled estimates of sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of FDG PET (PET/CT) in the detection of metastatic HCC were 76.6%, 98.0%, 14.68, and 0.28, respectively. The pooled estimates of sensitivity, specificity, LR+ and LR− of FDG PET (PET/CT) in the detection of recurrent HCC were 81.7%, 88.9%, 4.72, and 0.19, respectively.

Conclusion

Based on the results of this systematic review, F-18 FDG PET (PET/CT) was useful in ruling in extrahepatic metastases of HCC and valuable for ruling out the recurrent HCC.  相似文献   

14.

Purpose

Both positron emission tomography/computed tomography (PET/CT) and diffusion-weighted magnetic resonance imaging (DW-MRI) are oncologic feasible techniques for evaluating the malignancy of tumors. Standardized uptake value (SUV) is a marker of tumor glucose metabolism detected by PET/CT. Apparent diffusion coefficient (ADC) measured by DWI can provide information about tissue cellularity. The aim of the study was to evaluate the correlation between SUV and ADC in untreated diffuse large B-cell lymphoma (DLBCL).

Materials and methods

Fifteen pre-therapy patients with histologically proven DLBCL underwent PET/CT and DWI examinations within two days. Tumor glucose metabolism was evaluated by the maximum and mean SUV (SUVmax and SUVmean) on the PET/CT images. The mean ADC value was measured directly on the parametric ADC maps.

Results

In total, 28 lymphoma lesions with best match PET/CT and DWI were identified and evaluated. The mean SUVmax and SUVmean were 16.8 and 11.1, respectively; the mean ADC was 0.74 × 10−3 mm2/s. There was no correlation between the mean ADC and the SUVmax or SUVmean.

Conclusion

SUV determined from PET/CT and ADC value measured from DWI are different indices for the diagnosis of tumor malignancy, they may provide complimentary functional information of tumor tissue.  相似文献   

15.

Objective(s)

Only few information exist about the diagnostic accuracy of PET/CT for restaging patients with metastatic recurrence of breast carcinoma. Therefore, our study hypothesis was to perform diagnostic contrast enhanced CT (ce-CT) and FDG-PET in a one-step investigation, to prove sensitivity of each modality and to determine whether diagnostic PET/CT adds information over PET or contrast enhanced CT alone for restaging of patients with suspected recurrence of breast cancer.

Methods

Fifty-two patients with suspected recurrence of breast cancer were included in our study. All of them were free of metastasis after the first line therapy. Indications for restaging were: Elevated tumor markers n = 32, clinical deterioration n = 16 and/or suspicious findings on other imaging studies n = 48. Integrated PET/CT was performed using contrast-enhanced diagnostic CT for attenuation correction.

Results

PET was correct in 44/52 patients (85%), ce-CT in 38/52 patients (73%) and PET/CT in 50/52 patients (96%). Sensitivity and specificity of lesion detection of PET, CT and PET/CT were 84%, 66% and 93%, and 100%, 92%, and 100%, respectively.

Discussion

PET/CT can improve staging and alter therapeutic options in patients suspected to have breast cancer recurrence and distant metastatic disease, primarily by demonstrating local or distant nodal involvement occult at other imaging studies. The added value of FDG-PET/CT over other diagnostic modalities is mainly expressed by the fact that a noninvasive whole-body evaluation is possible in a single examination.  相似文献   

16.

Purpose

To compare the diagnostic performance of Gd-EOB-DTPA-enhanced MRI with that of triple phase 64-MDCT in the detection of hepatocellular carcinoma (HCC).

Patients and methods

Thirty-four patients with 52 surgically proven lesions underwent Gd-EOB-DTPA-enhanced MRI and triple phase 64-MDCT. Two observers independently evaluated MR and CT imaging on a lesion-by-lesion basis. Sensitivity, positive and negative predictive values and reproducibility were evaluated. The diagnostic accuracy of each modality was assessed with alternative-free response receiver operating characteristic (ROC) analysis.

Results

Both observers showed higher sensitivity in detecting lesions with MRI compared to CT, however, only the difference between the two imaging techniques for observer 2 was significant (P = 0.034). For lesions 1 cm or smaller, MRI and CT showed equal sensitivity (both 62.5%) with one observer, and MRI proved superior to CT with the other observer (MRI 75% vs. CT 56.3%), but the latter difference was not significant (P = 0.083). The difference in positive and negative predictive value between the two imaging techniques for each observer was not significant (P > 0.05). The areas under the ROC curve for each observer were 0.843 and 0.861 for MRI vs. 0.800 and 0.833 for CT and the differences were not significant. Reproducibility was higher using MRI for both observers, but the result was not significant (MRI 32/33 vs. CT 29/33, P = 0.083).

Conclusion

Gd-EOB-DTPA-enhanced MRI tended to show higher diagnostic accuracy, sensitivity and reproducibility compared to triple phase 64-MDCT in the detection of hepatocellular carcinoma, however statistical significance was not achieved.  相似文献   

17.

Background

Computed tomography (CT) and magnetic resonance imaging (MRI) utilization in Ontario increased drastically since the early 1990s. The effect of an increased number of cancer diagnoses, and an increase in indications for scans has not been assessed. This study was conducted to determine trends in utilization of CT and MRI in cancer patients in Ontario over a period of 9 years.

Methods

Using Ontario Health Insurance Plan billing data linked to the Ontario Cancer Registry, rates of CT and MRI were analyzed by region, year, scan type and socioeconomic status.

Results

CT in cancer patients increased 2.3-fold and accounted for approximately 24% of these scans. MRI in cancer patients increased by 4.2-fold and accounted for approximately 10% of these scans. Imaging rates for cancer patients increased more gradually than that of the general population. Substantial variation in the rate of both scans by region of patient residence existed. Even greater variation by the location of the scanner was demonstrated, indicating that many cancer patients traveled outside their region for imaging. There was little evidence of variation in scanning rates by socioeconomic status.

Conclusion

A minority of CT and MRI performed in Ontario are for cancer care. Regional variation in imaging rates suggest that utilization guidelines be developed or knowledge transfer initiatives improve compliance to existing guidelines are needed. A significant number of cancer patients travel outside their region for diagnostic imaging; this should influence decisions about the location of new scanners.  相似文献   

18.

Purpose

To review our experience with fetal magnetic resonance imaging (MRI) to evaluate congenital heart disease (CHD).

Methods

We performed fetal MRI in 32 fetuses with an echocardiographically assessed CHD. Both direct and indirect signs of CHD were investigated. Direct signs considered were: morpho-volumetric abnormalities of the heart; malrotations; ventricular and atrial septal defects; anomalies of the origin, size and course of the great arteries. Indirect signs considered were: difficulty to recognize a “normal” anatomical structures in the reference projections; increase of the vascular size before a stenosis; hypertrophy of the papillary muscles; cardiomegaly and pericardial effusion. All MRI findings were compared with postnatal or autoptic findings.

Results

MRI allowed the CHD to be visualised by direct signs in 17 fetuses, indirect signs in 5 and both direct and indirect signs in 9 fetuses, excluding the prenatal echocardiographic suspect of hypoplastic left heart syndrome in 1 fetus.Postnatal echocardiograms or autoptic findings confirmed a normal heart in 1 fetus and CHD in 31 fetuses including a single cardiac anomaly or syndrome in 19 fetuses, 2 associated cardiac abnormalities in 11 and 3 cardiac anomalies in 1 fetus.However, in 2 fetuses MRI detected a ventricular septal defect successively disclosed by gold standard.

Conclusions

MRI is a promising method for further assessment of the cardiovascular pathologies diagnosed by echocardiography, and may be a valuable tool in assessing associated extracardiac anomalies.  相似文献   

19.

Aim

Cholangiolocellular carcinoma (CoCC) is currently considered to originate from hepatic progenitor cells. The purpose of this study was to evaluate the imaging features of cholangiolocellular carcinoma of the liver.

Materials and methods

Five cases of surgically resected cases of CoCC from 4 institutions were retrospectively evaluated. All of the five patients underwent contrast-enhanced dynamic CT. MRI and angio-CT including CT during arterioportography (CTAP) and CT during hepatic arteriography were performed in 3 and 2 patients, respectively. Histological evaluation was also performed and was correlated with radiographic findings.

Results

On dynamic CT or MRI, the lesions presented hypervascular tumors with delayed washout in 2 cases and in the other 3 cases, the lesions showed peripheral enhancement with concentric delayed filling. On CTAP, the continued existence of portal veins or tiny spots of portal flow was identified in the tumors. Fibrous capsule or tumor necrosis was not observed.

Conclusion

CoCC tumors have the dual imaging characteristics of hepatocellular carcinoma and cholangiocarcinoma. The absence of a fibrous capsule, the absence of tumor necrosis, peripheral location within the liver, and the presence of portal venous penetration within the tumor also appear to be characteristic features.  相似文献   

20.

Purpose

To compare diagnostic capability of preoperative N-staging of lung cancer between thin-section CT of the mediastinum and FDG PET, and 5 mm slice thickness CT.

Materials and methods

The subjects were 34 patients with lung carcinoma who were examined by both CT and PET, and subsequently underwent surgery between May 2005 and January 2007. CT was carried out with a 16 detector row helical CT scanner. The raw data were reconstructed into 5 mm slice thickness and 1 mm slice thickness (thin-section CT). A total of 251 lymph node stations were retrospectively assessed for the presence of lymph node metastasis with thin-section CT, 5 mm CT and PET. In the interpretations of thin-section CT and 5 mm CT, we employed multi-criteria as follows: nodular calcification and intranodal fat as benign criteria, and short-axis diameter more than 10 mm (size criterion), focal low density other than fat, surrounding fat infiltration and convex margin in hilar lymph nodes, as malignant criteria. On PET, maximum standardized uptake value (SUVmax) of 2.5 or more was used as the criterion of malignancy. Sensitivity and specificity were compared between these examinations using McNemar test.

Results

Sensitivities and specificities of thin-section CT, 5 mm CT and PET were 25%, 25%, 25%, and 97%, 94%, 98%, respectively. The statistical analysis revealed that the specificity of 5 mm CT was significantly lower than those of thin-section CT (p = 0.039) and PET (p = 0.006), while no difference was present between thin-section CT and PET.

Conclusion

Thin-section CT of the mediastinum using multiple criteria was comparable to PET in preoperative N-staging of lung cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号