共查询到20条相似文献,搜索用时 93 毫秒
1.
Thirty anaesthetists attempted to place a derived 'optimal' curve bougie or a straight bougie in the trachea of a manikin, in a randomised cross-over study. A Grade 3 Cormack and Lehane laryngoscopic view was simulated. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates with the curved and straight bougies were 83 and 7%, respectively, giving a difference (95% confidence interval) of 77% (54-87%) between the two bougies (p < 0.0001). On a separate occasion, under identical laboratory conditions, 30 anaesthetists attempted to place a straight coudé (angled)-tipped bougie or a straight straight-tipped bougie in the trachea of a manikin. The success rates with the coudé- and straight-tipped bougies were 43 and 0%, respectively, giving a difference (95% confidence interval) of 43% (21-61%) between the two bougies (p < 0.001). These results suggest that bougies used to facilitate difficult intubation should be curved and have a coudé tip. 相似文献
2.
We examined the use of the 30 degrees rigid nasendoscope in aiding difficult tracheal intubations. A Cormack and Lehane grade 4 difficult intubation (no view of glottis or epiglottis) was set up on a manikin. After 10 s of tuition, 40 anaesthetists attempted to pass a standard gum elastic bougie between the cords, with and without the nasendoscope, in randomised order. A bougie curved to an 'optimal curve' was also tested. Using the standard bougie 13/40 (33%) passed the bougie between the cords without the nasendoscope, compared with 31/40 (78%) when using the nasendoscope (p < 0.001). The 'optimal curve' bougie resulted in 29/40 (73%) and 39/40 (98%) success rates without and with the nasendoscope, respectively (p = 0.004). The nasendoscope is a simple and easy to use tool in grade 4 intubation, and results are improved further by the use of an 'optimal curve' bougie. 相似文献
3.
Simulated difficult intubation 总被引:4,自引:0,他引:4
A randomised study was carried out to compare the efficacy of the gum elastic bougie and the stylet in a simulated difficult intubation. A laryngoscopy assessment, as described by Cormack and Lehane, was made in 100 patients. A Grade 3 view was then simulated. In the Bougie First Group (50 patients) two attempts were made to pass a gum elastic bougie and a tracheal tube into the trachea. If these first two attempts were not successful, two further attempts at intubation were allowed with a stylet placed in the tracheal tube. In the Stylet First Group (50 patients) the order was reversed. After two attempts the tube was correctly placed in the trachea in 96% of cases in the Bougie First Group compared to only 66% of cases in the Stylet First Group (p < 0.001). We recommend that a gum elastic bougie should be readily available and that anaesthetists should use it in preference to a stylet whenever a good view of the glottis is not immediately available. 相似文献
4.
In a randomised cross-over study, 50 anaesthetists attempted to place a multiple-use bougie in the trachea of a manikin, when holding it at either 20 cm or 30 cm from the tip. A grade 3 laryngoscopic view was simulated. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates when held at 20 and 30 cm distance from the tip were 68 and 62%, respectively (p = 0.55). In a separate experiment, multiple and single-use bougies were held at four different positions and pressed onto a disc attached to a force transducer. The peak force exerted by the single-use bougies was two to three times greater than that which could be exerted by the multiple-use bougies (p < 0.0001). Holding the bougie at either 20 or 30 cm distance from the tip is unlikely to influence bougie placement. The single-use bougie is much more likely to cause trauma to tissue during placement, particularly if held close to the tip. 相似文献
5.
6.
We studied the success rates for tracheal intubation in 32 healthy, anaesthetised patients during simulated grade IIIa laryngoscopy, randomised to either the multiple-use or the single-use bougie. Success rates (primary end-point) and times taken (secondary end-point) to achieve tracheal intubation were recorded. The multiple-use bougie was more successful than the single-use one (15/16 successful intubations vs. 9/16; p = 0.03). With either device, median [range] total tracheal intubation times for successful attempts were < 54 [24-84] s and there were no clinically important differences between these times. We conclude that the multiple-use bougie is a more reliable aid to tracheal intubation than the single-use introducer in grade IIIa laryngoscopy. 相似文献
7.
In a randomised cross-over study, 48 anaesthetists attempted to place a Frova single-use introducer, an Eschmann multiple-use introducer and a Portex single-use introducer in the trachea of a manikin set up to simulate a grade 3 laryngoscopic view. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). Successful placement (proportion, 95% confidence interval) of either the Frova introducer (65%, 50-77%) or the Eschmann introducer (60%, 46-73%) was significantly more likely than with the Portex introducer (8%, 3-20%). There were no significant differences between the success rates for the Frova and the Eschmann introducers. A separate experiment revealed that the peak force exerted by the Frova and Portex introducers was two to three times greater than that which could be exerted by the Eschmann introducer, p < 0.0001, indicating that the single-use introducers are more likely to cause tissue trauma during placement. 相似文献
8.
Data were collected prospectively on the use of the gum elastic bougie in 200 patients. The bougie was successfully inserted into the trachea and tracheal intubation was accomplished in 199 cases. The bougie was inserted into the trachea at the first attempt in 178 cases. In nine cases (4.5%) a second, more experienced, clinician was required. In 173 cases, the grades of view were recorded before and after the application of laryngeal pressure; pressure improved the view in 80 cases (46%), had no effect in 89 (51%) and worsened the view in four cases (2%). Various recommendations for optimal external laryngeal pressure and use of the bougie were not followed on 15-64% of occasions. There is a need for better education in these techniques. 相似文献
9.
We studied the success rates for tracheal intubation in 64 healthy patients during simulated grade III laryngoscopy after induction of anaesthesia, using either the single-use bougie or oral flexible intubating fibrescope, both in conjunction with conventional Macintosh laryngoscopy. Patients were randomly allocated to either simulated grade IIIa or grade IIIb laryngoscopy, and also to one of the two study devices. Success rates for tracheal intubation (primary outcome measure) and times taken to achieve intubation (secondary outcome measure) were recorded. For the simulated grade IIIa laryngoscopy group, the fibreoptic scope was more successful than the bougie (16/16 successful intubations vs. 8/16; p = 0.02). For the simulated grade IIIb laryngoscopy group, the fibreoptic scope was also more successful than the bougie (8/16 successful intubations vs. 1/16; p = 0.02), but clearly use of the fibreoptic scope was not as successful as it had been in simulated grade IIIa laryngoscopy (p = 0.04). With either device, median (range) total tracheal intubation times for successful attempts with either grade of laryngoscopy were less than 60 s (19-109) and there were no clinically important differences. We conclude that the fibrescope used in conjunction with Macintosh laryngoscopy is a more reliable method of tracheal intubation than the single-use bougie in both types of grade III laryngoscopy. This finding has implications for the management of patients in whom grade III laryngoscopy is encountered unexpectedly after induction of anaesthesia, and also for the management of patients previously known to have grade III view at laryngoscopy. 相似文献
10.
11.
S. M. YENTIS 《Anaesthesia》1987,42(7):764-766
Tracheal intubation may be hindered by difficulty in insertion of the laryngoscope blade into the patient's mouth because the handle impinges on the patient's chest or on the hand of an assistant applying cricoid pressure. An adaptor is described which modifies the standard Penlon laryngoscope to enable lateral swivelling of the handle, thus avoiding the obstruction. 相似文献
12.
Handling and efficacy of a new video-optical intubation stylet were assessed in a simulated difficult tracheal intubation setting and compared with a conventional malleable stylet. Forty-five anaesthetists performed 10 tracheal intubations using both techniques. Laryngoscopy was performed by the observer, who created a grade 3 view according the classification by Cormack and Lehane. The time taken to place the tracheal tube and the final tracheal tube positions were documented. Mean (SD) intubation time for the video-optical stylet was 20.4 (7.7) s and for the malleable stylet 10.2 (3.3) s (p<0.01). With the video-optical stylet the trachea was correctly intubated in all 225 attempts; with the malleable stylet 44 (19.6%) oesophageal and 44 (19.6%) endobronchial intubations occurred (p<0.01). The video-optical intubation stylet enabled us to recognise inappropriate tracheal tube positions and to correct them immediately. This equipment can be considered a reliable and effective tool for management of the difficult airway. 相似文献
13.
Fibreoptic intubation using the cuffed oropharyngeal airway and Aintree intubation catheter 总被引:2,自引:0,他引:2
A cuffed oropharyngeal airway has recently been introduced which has larger internal dimensions than a comparable Guedel airway. This allows a ventilation/exchange bougie, the Aintree Intubation Catheter, mounted on a fibreoptic laryngoscope to pass through it. Its 15-mm connector and pharyngeal cuff suggested the possibility of using a Rüsch sealed-port angle piece to allow ventilation through the oropharyngeal airway during fibreoptic laryngoscopy. This study investigated using this equipment to intubate the trachea through the cuffed oropharyngeal airway in paralysed patients, whilst maintaining ventilation manually with a Bain system. In 20 patients, airway control was satisfactory throughout and tracheal intubation was accomplished without complications. The cuffed oropharyngeal airway was easy to manipulate to improve a suboptimal fibreoptic view of the larynx. This may give it an advantage over the laryngeal mask airway when used as a ventilation/intubation conduit. 相似文献
14.
We describe the anaesthetic management of a patient with acromegaly scheduled for transsphenoidal resection of a pituitary tumour who was found at intubation to have coexisting laryngeal papillomatosis. Oral intubation was impossible using both direct and fibreoptic techniques. Nasal fibreoptic intubation was successful but precluded the transsphenoidal approach to surgery. A Cook Airway Exchange Catheter [Cook (UK) Ltd, Monroe House, Letchworth SG6 1LN] was used with a Negus bronchoscope to convert to oral intubation and allow completion of surgery without resort to tracheostomy. 相似文献
15.
Successful difficult intubation 总被引:4,自引:0,他引:4
The reliability of two signs of tracheal placement of a gum elastic bougie was studied. These signs were clicks (produced as the tip of the bougie runs over the tracheal cartilages) and hold up of the bougie as it is advanced (when the tip reaches the small bronchi). Ninety-eight simulated and two genuine Grade 3 difficult intubations were attempted with the aid of a gum elastic bougie. Seventy-eight tracheal and 22 oesophageal placements of the bougie resulted. No clicks or hold up occurred with the bougie in the oesophagus. Clicks were recorded in 89.7% of tracheal placements of the bougie. Hold up at between 24-40 cm occurred in all tracheal placements. We conclude that these signs are reliable and that they should be taught as part of any difficult intubation drill in which the gum elastic bougie is used. 相似文献
16.
17.
A patient with a previous surgical history of a cleft lip and palate repair and a pharyngeal flap pharyngoplasty was admitted for repair of mandibular prognathism. Following induction of anaesthesia, it was impossible to advance the nasotracheal tube into the oropharynx. Using a dental mirror and retrograde tracheal intubation equipment, under direct vision, the nasotracheal tube was finally advanced into the oropharynx. 相似文献
18.
I. A. Chadha MD Associate Professor S. T. Multani MD Professor Head A. Chadha MS MCh Professor Head 《Anaesthesia》1996,51(12):1160-1161
Difficulty during tracheal intubation may occur due to a number of anatomical factors and pathological conditions. These factors may be influenced by earlier surgical manoeuvres, so that dificulty may occasionally be encountered at subsequent operation. One such case of'iatrogenic'dificulty, where a tissue expander beneath the anterolateral skin of the neck caused transient intubation problems, is reported. 相似文献
19.
A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation 总被引:4,自引:0,他引:4
We conducted a prospective randomised study to compare the intubating laryngeal mask tracheal tube with a standard tube, for ease of tracheal intubation over a fibrescope. Thirty-six patients were investigated, using a sequential analysis technique. Ease of intubation was improved when the intubating laryngeal mask tracheal tube was used compared with the standard tube (p = 0.0009). Median (interquartile range [range]) intubation times (time from the tube's tip being level with the patient's teeth to successful placement) were 1.5 (1-2.3 [1-3]) s when the intubating laryngeal mask tracheal tube was used and 5 (3-7.3 [3-13]) s when the standard tube was used (p < 0.0001). 相似文献
20.
Body posture during simulated tracheal intubation 总被引:1,自引:0,他引:1
Seventeen experienced anaesthetists and 15 novices were filmed intubating the trachea of a training manikin. Measurements were made of the distance from manikin's chin to subject's nose and of the angles at the elbow, the shoulder and of the forearm with the horizontal. Trained subjects stood further back (trained: median 43 cm, interquartile range 41–56 cm; novices 35 cm, 26–38 cm; Mann–Whitney U , p < 0.01), with a straighter arm (trained elbow angle: 108°, 99–121°; novices': 92°, 88–102°; Mann–Whitney U , p < 0.01). Trained subjects tended to hold the laryngoscope closer to the hinge, with a pincer grip; novices were more likely to use a full grip of the handle. Trainers should consider giving novices explicit intructions on how to stand and how to hold the laryngoscope. 相似文献