首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

There is none, to our knowledge, about comparison of high-flexion fixed-bearing and high-flexion mobile-bearing total knee arthroplasties (TKAs) in the same patients. The purpose of this study was to determine whether clinical results; radiographic and computed tomographic scan results; and the survival rate of a high-flexion mobile-bearing TKA is better than that of a high-flexion fixed-bearing TKA.

Methods

The present study consisted of 92 patients (184 knees) who underwent same-day bilateral TKA. Of those, 17 were men and 75 were women. The mean age at the time of index arthroplasty was 61.5 ± 8.3 years (range 52-65 years). The mean body mass index was 26.2 ± 3.3 kg/m2 (range 23-34 kg/m2). The mean follow-up was 11.2 years (range 10-12 years).

Results

The Knee Society knee scores (93 vs 92 points; P = .531) and function scores (80 vs 80 points; P = 1.000), WOMAC scores (14 vs 15 points; P = .972), and UCLA activity scores (6 vs 6 points; P = 1.000) were not different between the 2 groups at 12 years follow-up. There were no differences in any radiographic and CT scan parameters between the 2 groups. Kaplan-Meier survivorship of the TKA component was 98% (95% confidence interval, 93-100) in the high-flexion fixed-bearing TKA group and 99% (95% confidence interval, 94-100) in the high-flexion mobile-bearing TKA group 12 years after the operation.

Conclusion

We found no benefit to mobile-bearing TKA in terms of pain, function, radiographic and CT scan results, and survivorship. Longer-term follow-up is necessary to prove the benefit of the high-flexion mobile-bearing TKA over the high-flexion fixed-bearing TKA.  相似文献   

2.

Background

Valgus knee deformity accounts for only 10% of total knee arthroplasties (TKAs), but is frequently considered the most challenging to manage. This study provides a 10-year follow-up on a previously reported series of severe valgus knees performed using an unconstrained mobile-bearing TKA with a modified technique to validate this technique.

Methods

A consecutive series of 275 predominantly cementless TKAs in 262 patients were performed for severe valgus (≥10°) deformity and prospectively followed to 10 years. Patient-reported outcome measures included the Oxford Knee Score, American Knee Society Score, Bartlett Patellar Score, and the Short Form 12 questionnaire.

Results

Average valgus deformity was reduced from 15.6° to 3.8° (P < .001). At a mean follow-up of 10.4 years (range, 9.5-14.1), 90 (34.4%) patients had died. Of the reviewed survivors, the mean Oxford Knee Score was 27.8 ± 9.8, with an American Knee Society clinical score of 85.6 ± 17.0 and a functional score of 65.1 ± 20.4, with 78% of patients reporting good to excellent results. To date, there has been 1 (0.36%) revision and 13 (4.73%) reoperations. Kaplan-Meier implant survival was 99.6% at 10 years.

Conclusion

Despite its challenging nature, the valgus knee is associated with excellent survivorship and satisfactory long-term results using this modified technique.

Level of Evidence

Level IV.  相似文献   

3.

Background

Bi-cruciate retaining (BCR) total knee arthroplasty (TKA) preserves both anterior and posterior cruciate ligaments with the potential to restore normal posterior femoral rollback and joint kinematics. However, there is limited information regarding articular contact behavior in the contemporary BCR TKA design during high knee flexion activities. This study aimed to investigate the articular knee contact performance in unilateral BCR TKA patients during strenuous flexion activities.

Methods

Twenty-nine unilateral BCR TKA patients were evaluated for both knees during single deep lunges, step-ups, and sit-to-stand (STS) using a validated combined computer tomography and dual fluoroscopic imaging system. Medial and lateral condylar contact positions were quantified during weight-bearing flexion.

Results

Contact excursions of the lateral condyle in BCR TKAs were significantly more anteriorly located than the contralateral non-operated knees during STS (?4.9 ± 3.1 vs ?9.7 ± 4.6 mm, P < .05), single deep lunge (?5.7 ± 3.2 vs ?10.0 ± 4.5 mm, P < .05), and step-ups (?4.8 ± 3.6 vs ?9.1 ± 3.9 mm, P < .05). Contact points of BCR TKAs indicated reduced femoral external rotation during STS (2.1 ± 4.8° vs 7.7 ± 5.4°, P < .05), single deep lunges (1.8 ± 4.8° vs 7.0 ± 7.1°, P < .05), and step-ups (0.1 ± 4.1° vs 6.2 ± 4.9°, P < .05). Medial pivoting patterns were observed in only 59%, 56%, and 48% of the BCR TKA knees for step-ups, STS, and single deep lunge, respectively.

Conclusion

The contemporary BCR TKA design demonstrated asymmetric femoral rollback, medial translation, as well as lateral pivoting in about half of the patient cohort, suggesting that in vivo tibiofemoral kinematic parameters were not fully restored in BCR patients during strenuous flexion activities.  相似文献   

4.

Background

The purpose of our prospective, randomized, long-term investigation is to compare the aseptic loosening rate of the femoral component of the total knee prosthesis and clinical and radiographic results of high-flexion posterior cruciate-substituting knee prosthesis or standard posterior cruciate-substituting knee prosthesis in the same patients.

Methods

There were 960 patients (mean age 71.3 years). The mean follow-up period was 13.2 years (range 10-14). The patients were assessed clinically and radiographically with rating systems of the Knee Society. Furthermore, Western Ontario and McMaster Universities Osteoarthritis questionnaire and ranges of knee motion were determined in both groups.

Results

In the high-flexion knee group, 2 knees (0.2%) had aseptic loosening of both femoral and tibial components. In the standard knee group, 2 knees (0.2%) had aseptic loosening of the femoral component only. The mean postoperative knee scores (97 vs 97 points), Western Ontario and McMaster Universities Osteoarthritis scores (19 vs 19 points), and range of knee motion (128° vs 129°) were not significantly different between the 2 groups. Two knees (0.2%) in the high-flexion knee group underwent a revision of both femoral and tibial components and 2 knees (0.2%) in the standard knee group had a revision of the femoral component only.

Conclusion

After a mean of 13.2 years of follow-up, this study did not show increased incidence of femoral component loosening in the high-flexion knee group. Furthermore, we found no significant differences between the 2 groups with regard to clinical or radiographic parameters or range of knee motion.  相似文献   

5.

Background

Both rotating-platform (RP) mobile-bearing and medial-pivot (MP) fixed-bearing prostheses allow axial femorotibial rotation using a highly conforming polyethylene insert. However, limited comparative data are available between the 2 designs. This study was performed to compare the midterm clinical outcomes and patient-reported outcome measures (PROMs) of RP and MP prostheses.

Methods

We retrospectively reviewed the records of 52 total knee arthroplasties using RP mobile-bearing prosthesis and 49 total knee arthroplasties using MP fixed prosthesis with a minimum follow-up period of 5 years. Clinical and radiological outcomes, failure rates, and PROMs, including the Western Ontario and McMaster Universities Osteoarthritis Index score and satisfaction, were compared.

Results

There was no difference in clinical or radiographic outcomes (P > .1 for all comparisons), with the exception of the larger flexion contracture (FC) in the MP group (0.3° in RP vs 2.3° in MP, P < .01). No failure in either group was recorded during the study period. PROMs were comparable (P > .1 in all comparisons), with the exception of higher satisfactions in the RP group while performing light household duties (P < .01) and leisure or recreational activities (P = .014) in patients without FC.

Conclusion

The midterm clinical results with both the RP mobile-bearing and MP fixed-bearing prostheses were satisfactory. Although both prostheses provided comparable PROMs, patients with an RP prosthesis were more satisfied than those with an MP prosthesis for highly demanding activities that are strongly associated with the presence of postoperative FC.  相似文献   

6.

Background

The aim of this study is to assess clinical results of total knee arthroplasty (TKA) with pre-operative patella alta or patella baja, compared to TKA with pre-operative normal patellar height.

Methods

Patella height was measured using the Blackburne-Peel (BP) method in an initial, prospective cohort of 4103 TKAs performed at a single center. Three groups were defined: normal patella height (0.54 < BP index ≤ 1.06), patella alta (BP index >1.06), and patella baja (BP index ≤0.54). Pre-operative and post-operative clinical and radiological characteristics were collected and compared. All prostheses used a system of posterior stabilization by a third condyle. The primary outcome measure was the post-operative Knee Society Score. Statistical analysis was performed using Student’s t-test and chi-squared test, with P < .05.

Results

Two hundred twenty-three TKAs with pre-operative patella alta, 307 TKAs with pre-operative patella baja, and 2248 with pre-operative normal patella height, mean follow-up 39.3 months (range 24-239), were ultimately included. Post-operatively, there was no difference between the 3 groups in terms of Knee Society Score (knee and function scores). Patella baja statistically decreased the maximal flexion (118.2° vs 115.5°, P = .002) and increased the rate of patellar fracture (0.9% vs 2%, P = .05). Finally, survival rates were similar in the 3 groups with each above 91% (±2%) at 10 years.

Conclusion

Clinical and radiological results for TKAs with pre-operative patella alta and patella baja were comparable to TKAs with a normal pre-operative patellar height. Risk of post-operative patellar fracture increased for patients with pre-operative patella baja.  相似文献   

7.
《The Journal of arthroplasty》2020,35(5):1262-1267
BackgroundAs previous studies are limited to short-term clinical data on conventional and high-flexion total knee arthroplasties (TKAs), long-term clinical data on these TKAs remain unclear. Therefore, we evaluated long-term functional outcome, range of knee motion, revision rate, implant survival, and the prevalence of osteolysis after conventional and high-flexion TKAs in the same patients.MethodsThe authors evaluated a cohort of 1206 patients with a mean age of 65.3 ± 7 years (range: 22-70) who underwent bilateral simultaneous sequential TKAs. One knee received a conventional TKA and the other received a high-flexion TKA. The mean duration of follow-up was 15.6 years (range: 14-17).ResultsNo significant differences were found between the 2 groups at the latest follow-up with respect to Knee Society score (93 vs 92 points, P = .765), pain score (45 vs 44 points, P = .641), range of knee motion (125° vs 126°, P = .712), and radiographic and computed tomography scan results. Furthermore, no significant revision rate differences were found between the 2 groups (1.3% for conventional TKA vs 1.6% for high-flexion TKA; P = .137). There was no osteolysis recorded in either group. The rate of survivorship free of implant revision or aseptic loosening was 98.7% (95% CI = 91-100) for conventional TKA and 98.4% (95% CI = 91-100) for high-flexion TKA at 17 years.ConclusionAt the latest follow-up, we were not able to demonstrate any significant difference between conventional and high-flexion TKAs with respect to functional outcome scores, range of knee motion, revision rate, implant survival, and prevalence of osteolysis.  相似文献   

8.

Background

We hypothesized that postoperative anteroposterior (AP) stability of the knee correlates with patient-reported clinical outcome and knee function after total knee arthroplasty (TKA).

Methods

This study enrolled 110 knees in 81 patients after TKA. AP laxity was measured with a KS Measure Arthrometer at 30°, 60°, and 90° flexion, which was confirmed with a goniometer. We assessed knee pain and function by using the Knee Society Function Score (KSS) and Knee Injury and Osteoarthritis Outcome Score (KOOS). Correlations among AP translation values and KOOS subscale scores (pain symptom, activities of daily living, and knee-related quality of life), KSS, and range of motion (ROM) were analyzed.

Results

The mean follow-up period for the assessment of the KOOS was 4.4 ± 2.2 years (range, 1.1-11.5 years). Twenty-five knees had posterior-stabilized fixed-bearing TKA, and 85 knees had posterior-stabilized mobile-bearing TKA. The mean KSS functional score and mean ROM were 96.3 ± 5.7 (range, 75-100) and 121.6° ± 14.4° (range, 90°-145°), respectively. The mean AP laxity was 4.5 ± 2.2 mm, 3.6 ± 1.9 mm, and 3.0 ± 1.9 mm at 30°, 60°, and 90° knee flexion, respectively. A significant inverse association was observed between AP laxity at 60° knee flexion and KOOS pain (P = .021, R2 = 0.05), but no significant association was found between AP laxity and other KOOS subscale score, KSS, and ROM.

Conclusion

We found that the AP laxity at 60° knee flexion in this study significantly correlated with patient-reported pain. The observed AP laxity can be considered as a register of normal AP translations after arthroplasty.  相似文献   

9.

Background

Management of severe varus deformity requires soft tissue balancing for implantation of low-constraint knee prosthesis. Patellar complications have been rarely studied in this specific group. Our hypothesis was that severe genu varum (>15°) would increase the rate of patellar complications.

Methods

Using a prospective cohort of 4216 prostheses performed at a single center beginning in 1987, we analyzed 280 prostheses having preoperative varus greater than 15°, compared to 673 total knee arthroplasties (TKAs) with a preoperative hip-knee-ankle angle of 180° ± 2°. Preoperative and postoperative clinical and radiological characteristics were compared between the 2 groups, with particular attention paid to patellar complications.

Results

Average follow-up was 40.2 months (24-239). The mean preoperative Knee Society Score (KSS) was statistically higher in the normal (hip-knee-ankle angle 180° ± 2) axis group (62.65 vs 37.47, P = .001). At the last follow-up, no significant difference was found between the 2 groups in terms of postoperative KSS (87.5 in the varus group vs 87.3 in the normal axis group, P = .87). The rate of satisfied patients was identical between the 2 groups (85.3% vs 88.8%, P = .49). However, at mid-term, there were more patellar fractures in the varus group (2.9% vs 0.9%, P = .005). A significantly lower patellar height in both the varus group and the group of patella fractures (P < .001) was also found.

Conclusion

TKA in severe varus knees produces a KSS equivalent to TKA in knees with a mechanical axis of 0 ± 2. The risk of patellar fracture could initiate a decline in patella resurfacing in patients with major varus deformation, especially in case of a preoperative patella baja.  相似文献   

10.

Background

Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants.

Methods

We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded.

Results

Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P < .01). The average knee flexion improved from 105.6° preoperatively to 117.4° postoperatively (P < .01). Eight patients required subsequent implant revision. No cases of bearing complications were observed.

Conclusion

Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post.  相似文献   

11.

Background

Anterior tibial post impingement during gait and stair ambulation was reported in knees with posterior-stabilized prostheses. However, the link between anterior post impingement and knee kinematics and between anterior post impingement and the clinical outcome has not been well investigated. Therefore, the purpose of this study was to assess the anterior impingement to clarify the relevant kinematics and clinical results including patient-reported outcomes.

Methods

We analyzed 40 well-functioning knees in 20 patients with a posterior-stabilized prosthesis due to osteoarthritis and who were followed up for 2 years or more. Dynamic lateral radiographs during stair-climbing activity were analyzed using a shape-matching technique, and anterior post impingement and the clinical outcome were assessed.

Results

Anterior impingement of the tibial post was observed in 13 knees (33%) during the latter half of the stance phase and at the beginning of the swing phase with the average implant flexion angle of ?2.4°. Implant flexion was significantly smaller, while the femoral component was located more posterior in the impingement knees. The posterior tibial slope was significantly greater in the impingement group (6.7° ± 2.0°, 5.3° ± 1.9°, respectively; P = .041); however, no significant differences were demonstrated in anteroposterior laxity and patient-derived assessments.

Conclusion

To avoid anterior post impingement, the posterior tibial slope should be made at 5° or less. Femoral notch-anterior post articulation should be designed to have good congruency in order to act as an anterior stabilizer in the case of impingement at knee extension.  相似文献   

12.

Background

The objective of the study was to compare the patient-reported outcome measures (PROM) of patients with post-traumatic arthritis (PTA) versus patients with osteoarthritis (OA) undergoing total knee arthroplasty (TKA) and compare the rates of revision among these two groups.

Methods

Using a prospectively held institutional registry, we retrospectively reviewed patients ≥60 years of age who underwent unilateral TKA between May 2007 and February 2012. Patients with previous or concomitant diagnosis of inflammatory arthropathy or an initial open fracture were excluded. PTA patients were matched 1:5 with OA patients undergoing TKA. Validated PROMs were recorded at baseline before index TKA and the last follow-up. Reason and time to revision surgery was reported, and survivorship was compared using Kaplan-Meier curves.

Results

Seventy-five PTA patients were matched to 375 OA patients. There was no difference between these groups with respect to age (67.7 ± 5.6 vs 67.8 ± 5.5 years; P = .876), body mass index (28.6 ± 5.4 vs 28.7 ± 5.3 kg/m2; P = .948), sex (65.3% vs 65.3% females; P = .999), Charlson Comorbidity Index (21.3% vs 21.3% Index 1-2, P = .999), and time to follow-up (93.0 ± 13.4 vs 88.2 ± 13.7 months; P = .999). No statistically significant difference was found in PROMs at baseline and the last follow-up (P > .05), the rate or time to revision surgery between the two groups (P-value = .635; log-rank test).

Conclusion

Unlike previous studies, TKA for PTA does not pose lower PROMs or higher revision rates when compared to TKA for OA. These results could help provide surgeons with a frame of reference in terms of expectations for patients with PTA undergoing TKA.  相似文献   

13.

Background

Soft tissue balance is believed to be a major determinant of improved outcomes in total knee arthroplasty (TKA). We conducted this study to assess the accuracy of surgeon-defined assessment (SDA) of knee balance compared to pressure sensor data. We also assessed for any association between experience (learning curve) and accuracy of SDA.

Methods

A total of 308 patients undergoing 322 mechanically aligned TKA were prospectively analyzed. Femoral and tibial trial implants were inserted before performing knee balancing. We compared the surgeon determination on knee balance at 10°, 45°, and 90° of flexion to sensor data at the same flexion angles.

Results

Accuracy of SDA was 63%, 57.5%, and 63.8% at 10°, 45°, and 90°, respectively, when compared to sensor data. SDA had an overall sensitivity of 81% and specificity of 37.7%. Capacity to determine an unbalanced knee worsened at higher knee flexion angles with SDA test specificity of 53.5%, 34.8%, and 24.8% at 10°, 45°, and 90°, respectively (P = .0004 at 10° vs 45°, P < .0001 at 10° vs 90°). Cohen’s kappa coefficient was 0.29 at 10° indicating fair agreement, and 0.14 and 0.12 at 45° and 90°, respectively, indicating poor agreement. The use of sensor had no time-based learning effect on capacity to determine knee balance.

Conclusion

SDA is a poor predictor of the true soft tissue balance when compared to sensor data, particularly in assessing whether a knee is unbalanced. In addition, increased use of sensors did not improve surgeon capacity to determine knee balance.  相似文献   

14.

Background

The purpose of this study is to compare surgical and clinical outcomes between matched groups of morbidly obese (body mass index [BMI] >40 kg/m2) and non-morbidly obese (BMI <40 kg/m2) patients undergoing first-time revision total knee arthroplasty with a minimum 5-year follow-up.

Methods

Two groups of 87 patients (BMI >40 or <40 kg/m2) were matched 1:1 based on age at the time of revision, gender, and diagnosis for revision (aseptic or septic causes).

Results

The morbidly obese group had a significantly greater incidence of re-operation (34.5% [30/87] vs 16.1% [14/87], P = .005) and re-revision (27.6% [24/87] vs 12.6% [11/87], P = .014) with a significantly lower 10-year survivorship for re-operation (P = .05) and subsequent revision (P = .014). In particular, the aseptic sub-group had a greater incidence of re-operation (29.9% [20/67] vs 13.4% [9/67], P = .021) and re-revision (26.9% [18/67] vs 11.9% [8/67], P = .029). The non-morbidly obese group demonstrated higher final Western Ontario and McMaster Universities Index scores (63.1 ± 19.5 vs 55.5 ± 22.5, P = .030) and a greater change between pre-operative and final KSS (45.6 ± 44.3 vs 39.7 ± 48.4, P = .040) and SF-12 Mental component (3.6 ± 10.8 vs ?1.4 ± 10.3, P = .013).

Conclusion

Morbidly obese patients undergoing revision total knee arthroplasty have a greater risk of re-operation and re-revision while experiencing lower clinical outcome scores compared to non-morbidly obese patients. These patients should be informed of the higher potential for re-operation and the possibility of poor results.  相似文献   

15.

Background

Total knee arthroplasty (TKA) in the morbidly obese patients can be challenging with an increased risk of complications. Studies have shown increased aseptic failures with well-aligned cemented TKAs in the obese patient. The purpose of this study is to determine if TKA in the morbidly obese (body mass index [BMI] ≥ 40) using cementless implants would demonstrate improved results and survivorship compared to cemented TKA at a minimum 5-year follow-up.

Methods

This is a retrospective study comparing clinical results of cemented vs cementless primary TKA with a posterior stabilized design TKA in morbidly obese (BMI ≥ 40) patients with minimal 5-year follow-up. There were 108 patients in the cementless group with a mean BMI of 45.6. In the cemented cohort, there were 85 cemented TKAs with a mean BMI of 45.0. Demographic, clinical, surgical, and radiographic data along with complications were extracted for all study patients.

Results

There were 5 failures requiring revision in the cementless group, including 1 for aseptic tibial loosening (0.9%). In the cemented group, there were 22 failures requiring revision, including 16 implants for aseptic loosening (18.8%; P = .0001). Survivorship with aseptic loosening as the endpoint was 99.1% in the cementless group vs 88.2% in the cemented cohort at 8 years (P = .02).

Conclusion

Morbidly obese patients (BMI ≥ 40) have a higher failure due to aseptic loosening with cemented TKA with decreasing survivorship over time. The use of cementless TKA in morbidly obese patients with the potential of durable long-term biologic fixation and increased survivorship appears to be a promising alternative to mechanical cement fixation.  相似文献   

16.

Background

Postoperative knee flexion angle is one of the most important outcomes of total knee arthroplasty (TKA). Intraoperative ligament balancing may affect the postoperative range of motion of the knee. However, the relationship between intraoperative ligament balancing and postoperative flexion angle was still controversial. The purpose of this study was to determine whether intraoperative joint gap affects postoperative knee flexion angle or not.

Methods

Prospective multicenter study of 246 knees with varus osteoarthritis undergoing a posterior–stabilized, mobile-bearing TKA was performed. The joint gap before implantation and after implantation was measured. The joint gap after implantation was measured using a specially designed tensor device with the same shape of a total knee prosthesis at 0°, 30°, 60°, 90°, 120°, and 145° of flexion with the reduction of the patellofemoral joint. Stepwise multiple regression analysis was conducted to determine the predictors of the flexion angle of the knee after the operation.

Results

Predictors were identified in the following 3 categories: (1) preoperative flexion angle, (2) intraoperative flexion angle, and (3) joint gap looseness at 120° of flexion (joint gap after implantation at 120° of flexion ? joint gap after implantation at 0° of flexion) (R = 0.472, P < .01).

Conclusion

Flexion angle after TKA was not affected by the flexion joint gap looseness before implantation and the joint gap looseness after implantation from 30° to 90° of flexion. Surgeons should notice that joint gap looseness in mid-flexion range did not increase the postoperative knee flexion angle.  相似文献   

17.

Background

Biomechanics after total knee arthroplasty (TKA) often remain abnormal and may lead to prolonged postoperative recovery. The purpose of this study is to assess a biomechanical therapy after TKA.

Methods

This is a randomized controlled trial of 50 patients after unilateral TKA. One group underwent a biomechanical therapy in which participants followed a walking protocol while wearing a foot-worn biomechanical device that modifies knee biomechanics and the control group followed a similar walking protocol while wearing a foot-worn sham device. All patients had standard physical therapy postoperatively as well. Patients were evaluated throughout the first postoperative year with clinical measures and gait analysis.

Results

Improved outcomes were seen in the biomechanical therapy group compared to the control group in pain scores (88% vs 38%, P = .011), function (86% vs 21%, P = .001), knee scores (83% vs 38%, P = .001), and walking distance (109% vs 47%, P = .001) at 1 year. The therapy group showed healthier biomechanical gait patterns in both the sagittal and coronal planes at 1 year.

Conclusion

A postoperative biomechanical therapy improves outcomes following TKA and should be considered as an additional therapy postoperatively.  相似文献   

18.

Background

Anterior knee pain (AKP) and/or crepitation are important causes of dissatisfaction after total knee arthroplasty (TKA). Aim of this prospective, matched-pair study was to compare 2 different designs of patellofemoral (ie, trochlear groove) TKA. The Attune knee has an anatomic trochlear groove with a medialized dome patellar component vs the PFC Sigma with a single radius trochlear groove with a domed shaped patella.

Methods

Between January 2010 and December 2014, 100 consecutive Attune TKAs were matched to 100 PFC Sigma TKAs based on age, gender, side, and body mass index. All surgeries were performed via medial parapatellar approach and used cemented, posterior-stabilized implants with patellar resurfacing. Clinical evaluations were assessed using Knee Society Scores (KSS) and a patient-administered questionnaire at 2-year follow-up (range, 1.5-3 years).

Results

Based on the KSS clinical rating system, excellent clinical results were achieved in 89.4% and 90.7% of Attune and PFC Sigma TKAs, respectively. There were no significant differences in the KS pain or function scores. The overall incidence of AKP was significantly lower with the Attune knee compared to that of the PFC Sigma (12.5% vs 25.8%; P = .02). The incidence of hearing or feeling noise was also less with the Attune knee (17.7% vs 30.9%; P = .02). The incidence of painful crepitation was low in both groups (1.0% vs 4.1%) with no significant difference between groups (P = .37). Both groups had similar high satisfaction scores of 8.6 and 8.4 for the Attune and PFC groups, respectively (P = .09).

Conclusion

At 2-year follow-up, there were no differences between the PFC Sigma and Attune knees in KSS or satisfaction. However, the Attune group had a lesser incidence of AKP and crepitation. Further studies should focus on AKP and noise in cruciate-retaining knees.  相似文献   

19.

Background

Total knee arthroplasty designs can be categorized by bearing design and fixation method. The mobile-bearing concept was developed with the aim of increasing longevity and improving function by reduced polyethylene wear and closer replication of physiological knee motion. Cementless fixation has the goal of achieving a long-lasting “biological” fixation between prosthesis and bone.

Methods

Prospective analysis of the survivorship and patient-reported functional outcomes of a series of 500 low contact stress rotating-platform mobile-bearing total knee arthroplasties with a cementless tibial component with a minimum 17-year follow-up.

Results

Five hundred primary total knee arthroplasties were conducted in 467 patients. Mean follow-up was 18.1 (17.0-21.8) years and 141 (28.2%) knees were alive and available for review. Using revision for any cause as the end point, cumulative survivorship was 97.4%. Thirteen knees required revision: 3 for deep infection, 3 bearing only revisions for spinout, 3 for tibial tray subsidence, 2 secondary patella resurfacings, 1 aseptic loosening, and 1 for suspected aseptic loosening that was found to be well fixed. Mean American Knee Society Scores were 83 (evaluation) and 48 (function), Mean Oxford Knee Score was 32.1, and the mean Bartlett Patellar Score was 21.6.

Conclusion

This series demonstrates excellent survivorship and acceptable patient-reported functional outcome scores of a mobile-bearing total knee arthroplasty with a cementless tibial tray at minimum 17-year follow-up.  相似文献   

20.

Background

Anterior knee pain (AKP) remains a complex issue affecting patient satisfaction after total knee arthroplasty. Several radiographic parameters have been shown to be causative factors with various designs. The aim of this study is to evaluate the known radiographic parameters of AKP and clinical outcomes (ie, AKP) in the setting of a modern prosthesis with an anatomic patella button.

Methods

Between July 2012 and December 2013, 90 total knee arthroplasties received 3 skyline views taken at 30°, 45°, and 60°. A patient-administered questionnaire was administered at 2-year follow-up to assess the incidence of AKP, painless noise, and satisfaction. Radiographs were analyzed for patellofemoral overstuffing, patellar tilt, and patellar displacement, and evaluated the patella resection angle.

Results

On the patient-administered questionnaire, 10 (11.1%) patients reported AKP of a mild-to-moderate nature. Thirty-one had the best view at 30 Merchant views, 24 had best views at 45, and 35 had best views at 60. We found that patellar resection angle correlated with AKP (odds ratio 1.21, P = .044) and painless noise (odds ratio 1.22, P = .034). Patellar displacement and patellofemoral stuffing did not correlate with AKP or painless noise. No radiographic measurements correlated with changes in Knee Society Score pain or function scores or range of motion.

Conclusion

We found that a patellar resection angle correlated with the incidence of AKP and painless noise at 2-year follow-up. We failed to find any correlation with patellofemoral overstuffing, patellar displacement, or patellar tilt with clinical outcomes. We recommend the use of 3 Merchant views to fully evaluate the patellofemoral joint.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号