首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In Doppler analysis, the power spectral density (PSD), which accounts for the axial velocity distribution of the blood scatterers, is estimated. The conventional spectral estimator is Welch's method, which suffers from frequency leakage at small observation window length. The performance of adaptive techniques such as blood power Capon (BPC) has been promising at the cost of higher computation complexity. Reducing the computational complexity while retaining the benefits of BPC would be necessary for real-time implementation. The purpose of the work described here was to investigate whether it is possible to decrease the computation load in BPC and still obtain acceptable results. The computation complexity in BPC is owing primarily to the matrix inversion required for computing the PSD estimate. We here propose the subspace blood power Capon technique, which employs a data covariance matrix with reduced number of rows in estimation of the weight vector. In maximum velocity estimation in the spectra, the signal noise slope intersection envelop estimator that makes use of the integrated power spectrum is employed. The evaluations are made based on both simulated and in vivo data. The results indicate that it is possible to reduce the order of complexity to almost 12.25% at the cost of 2.31% and 2.24% increases in the relative standard deviation and relative bias of the estimates. Moreover, the Wiener post-filter as a post-weighting factor, which will be multiplied by the final weight vector of the spectral estimator, estimates the power of the desired signal and the power of the interference plus noise to improve the contrast. The proposed estimator has exhibited a promising performance at beam-to-flow angles of 45°, 60° and 75°. Furthermore, the robust performance of the proposed estimator against variation in the flow rate is also documented.  相似文献   

2.
The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (VFI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance angiography (MRA); (iii) the precision of VFI estimation in vivo at several evaluation points in the vessels. The carotid artery at the bifurcation was scanned using both fast plane wave ultrasound and MRA in 10 healthy volunteers. The MRA geometry acquired from one of the volunteers was used to fabricate an anthropomorphic flow phantom, which was also scanned using the fast plane wave sequence. The same geometry was used in a CFD simulation to calculate the velocity field. Results indicated that similar flow patterns and vortices were estimated with CFD and VFI in the phantom for the carotid bifurcation. The root-mean-square difference between CFD and VFI was within 0.12?m/s for velocity estimates in the common carotid artery and the internal branch. The root-mean-square difference was 0.17?m/s in the external branch. For the 10 volunteers, the mean difference between VFI and MRA was ?0.17?m/s for peak systolic velocities of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD?=?3.6% for velocity magnitudes and 4.5° for angles) and lowest in the external branch and for vortices (SD?=?10.2% for velocity magnitudes and 39° for angles). The results indicate that plane wave VFI measures flow precisely and that estimates are in good agreement with a CFD simulation and MRA.  相似文献   

3.
Ultrasound (US) examination of the common carotid artery was compared with a through-plane magnetic resonance imaging (MRI) sequence to validate a recently proposed technique for 3-D US vector flow imaging. Data from the first volunteer examined were used as the training set, before volume flow and peak velocities were calculated for the remaining eight volunteers. Peak systolic velocities (PSVs) and volume flow obtained with 3-D US were, on average, 34% higher and 24% lower than those obtained with MRI, respectively. A high correlation was observed for PSV (r = 0.79), whereas a lower correlation was observed for volume flow (r = 0.43). The overall standard deviations were ±5.7% and ±5.7% for volume flow and PSV with 3-D US, compared with ±2.7% and ±3.2% for MRI. Finally, the data were re-processed with a change in the parameter settings for the echo-canceling filter to investigate its influence on overall performance. PSV was less affected by the re-processing, whereas the difference in volume flow between 3-D vector flow imaging and MRI was reduced to ?9%, and with an improved overall standard deviation of ±4.7%. The results illustrate the feasibility of using 3-D US for precise and angle-independent volume flow and PSV estimation in vivo.  相似文献   

4.
Risk stratification in coronary artery disease is an ongoing challenge for which few tools are available for quantifying physiology within coronary arteries. Recently, anatomy-driven computational fluid dynamic modeling has enabled the mapping of local flow dynamics in coronary stenoses, with derived parameters such as WSS exhibiting a strong capability for predicting adverse clinical events on a patient-specific basis. As cardiac catheterization is common in patients with coronary artery disease, minimally invasive technologies capable of identifying pathologic flow in situ in real time could have a significant impact on clinical decision- making. As a step toward in vivo quantification of slow flow near the arterial wall, proof-of-concept for 3-D intravascular imaging of blood flow dynamics is provided using a 118-element forward-viewing ring array transducer and a research ultrasound system. Blood flow velocity components are estimated in the direction of primary flow using an unfocused wave Doppler approach, and in the lateral and elevation directions, using a transverse oscillation approach. This intravascular 3-D vector velocity system is illustrated by acquiring real-time 3-D data sets in phantom experiments and in vivo in the femoral artery of a pig. The effect of the catheter on blood flow dynamics is also experimentally assessed in flow phantoms with both straight and stenotic vessels. Results indicate that 3-D flow dynamics can be measured using a small form factor device and that a hollow catheter design may provide minimal disturbance to flow measurements in a stenosis (peak velocity: 54.97 ± 2.13 cm/s without catheter vs. 51.37 ± 1.08 cm/s with hollow catheter, 6.5% error). In the future, such technologies could enable estimation of 3-D flow dynamics near the wall in patients already undergoing catheterization.  相似文献   

5.
In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is “smeared”) if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method across a field of view and combination with an appropriate axial flow estimator.  相似文献   

6.
The purpose of this study was to measure changes in cardiac function as cardiomyopathy progresses in a mouse model of Duchenne muscular dystrophy using 3-D ECG-gated echocardiography. This study is the first to correlate cardiac volumes acquired using 3-D echocardiography with those acquired using retrospectively gated micro-computed tomography (CT). Both were further compared with standard M-mode echocardiography and histologic analyses. We found that although each modality measures a decrease in cardiac function as disease progresses in mdx/utrn–/– mice (n = 5) compared with healthy C57BL/6 mice (n = 8), 3-D echocardiography has higher agreement with gold-standard measurements acquired by gated micro-CT, with little standard deviation between measurements. M-Mode echocardiography measurements, in comparison, exhibit considerably greater variability and user bias. Given the radiation dose associated with micro-CT and the geometric assumptions made in M-mode echocardiography to calculate ventricular volume, we suggest that use of 3-D echocardiography has important advantages that may allow for the measurement of early disease changes that occur before overt cardiomyopathy.  相似文献   

7.
A vascular vector flow mapping (VFM) method visualizes 2-D cardiac flow dynamics by estimating the radial component of flow from the Doppler velocities and wall motion velocities using the mass conservation equation. Although VFM provides 2-D flow, the algorithm is applicable only to bounded regions. Here, a modified VFM algorithm, vascular VFM, is proposed so that the velocities are estimated regardless of the flow geometry. To validate the algorithm, a phantom mimicking a carotid artery was fabricated and VFM velocities were compared with optical particle image velocimetry (PIV) data acquired in the same imaged plane. The validation results indicate that given optimal beam angle condition, VFM velocitiy is fairly accurate, where the correlation coefficient R between VFM and PIV velocities is 0.95. The standard deviation of the total VFM error, normalized by the maximum velocity, ranged from 8.1% to 16.3%, whereas the standard deviation of the measured input errors ranged from 8.9% to 12.7% for color flow mapping and from 4.5% to 5.9% for subbeam calculation. These results indicate that vascular VFM is reliable as its accuracy is comparable to that of conventional Doppler-flow images.  相似文献   

8.
Aims and objectives. To assess the capability of infrared ear thermometry accurately to predict rectal temperature in older patients. Background. Infrared ear thermometry is now commonly used for predicting body temperature in older patients. However, ear thermometry has been insufficiently evaluated in geriatric patients. Design. Prospective, convenience sample, unblinded study. Methods. All patients (or their guardians) gave informed consent. Patients hospitalised in a geriatric unit underwent sequential ear and rectal temperatures measurements using two different models of infrared ear thermometers (ThermoScan and Genius) and a rectal probe, respectively. After a brief otoscopic examination, ear temperatures were measured twice at both ears with each thermometer, the highest of four measurements being retained for analysis. The rectal temperature was the reference standard. Results. Hundred patients (31 males), aged 81 (SD 7) years completed the study. The mean rectal temperature was 37·3 °C (SD 0·7) °C (range 36·3–40·7 °C). Eighteen patients were febrile (rectal temperature ≥ 37·8 °C). The mean bias between rectal and ear temperatures as measured with the ThermoScan was –0·20 °C (SD 0·32) °C and the 95% limits of agreement were –0·83 °C and 0·42 °C (95% CI, –0·88–0·48 °C). Using the Genius, the corresponding figures were –0·56 °C (SD 0·39) °C, –1·32 °C and 0·20 °C (95% CI, –1·39–0·27 °C). After correction for bias, the ThermoScan predicted the level of fever with a maximum error of 0·7 °C (mean error 0·3 °C). Using the Genius, the maximum error and the mean error were 1·6 °C and 0·4 °C, respectively. Conclusions. Infrared ear thermometry can predict rectal temperature in normothermic and in febrile inpatients with an acceptable level of accuracy. However, the predictive accuracy depends on both operator technique and quality of instrumentation. Relevance to clinical practice. Proper technique (measuring in both ears) and optimal instrumentation (model of ear thermometer) are essential for accuracy.  相似文献   

9.
The purpose of this study is to show whether a newly introduced vector flow method is equal to conventional spectral estimation. Thirty-two common carotid arteries of 16 healthy volunteers were scanned using a BK Medical ProFocus scanner (DK-2730, Herlev, Denmark) and a linear transducer at 5 MHz. A triplex imaging sequence yields both the conventional velocity spectrum and a two-dimensional vector velocity image. Several clinical parameters were estimated and compared for the two methods: Flow angle, peak systole velocity (PS), end diastole velocity (ED) and resistive index (RI). With a paired t-test, the spectral and vector angles did not differ significantly (p = 0.658), whereas PS (p = 0.034), ED (p = 0.004) and RI (p < 0.0001) differed significantly. Vector flow can measure the angle for spectral angle correction, thus eliminating the bias from the radiologist performing the angle setting with spectral estimation. The flow angle limitation in velocity estimation is also eliminated, so that flow at any angle can be measured.  相似文献   

10.
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis and usually occurs at the ostia of coronary arteries. In this study, we used transthoracic Doppler echocardiography (TTDE) to evaluate the dynamic changes of coronary flow in HoFH patients and to detect aortic and coronary atherosclerosis by dual-source computed tomography (DSCT). We studied 20 HoFH patients (12 females, 8 males, mean age 13.1 ± 5.3 years, with a mean low density lipoprotein (LDL) cholesterol of 583 ± 113 mg/dL) and 15 control patients (8 females, 7 males, mean age 15.2 ± 6.9 years, with a mean LDL cholesterol 128 ± 71 mg/dL) using TTDE and DSCT. None of the patients showed evidence of ischemia with standard exercise testing. Though the baseline coronary flow was similar between HoFH patients and normal controls, the hyperemic flow velocities and, thus, the coronary flow velocity reserve (CFVR) were significantly lower in those with HoFH. All HoFH patients had aortic plaques, nine of them with the coronary artery ostia simultaneously, who had significantly higher LDL-cholesterol and lower CFVR than those without ostia plaques. Our data demonstrated that TTDE together with DSCT could be a useful noninvasive method for detection of coronary flow dynamics and atherosclerosis specifically in HoFH subjects with coronary ostia. (E-mail: lizhian_anzhen@yahoo.com.cn)  相似文献   

11.
Abnormal blood flow is usually assessed using spectral Doppler estimation of the peak systolic velocity. The technique, however, only estimates the axial velocity component, and therefore the complexity of blood flow remains hidden in conventional ultrasound examinations. With the vector ultrasound technique transverse oscillation the blood velocities of both the axial and the transverse directions are obtained and the complexity of blood flow can be visualized. The aim of the study was to determine the technical performance and interpretation of vector concentration as a tool for estimation of flow complexity. A secondary aim was to establish accuracy parameters to detect flow changes/patterns in the common carotid artery (CCA) and the carotid bulb (CB). The right carotid bifurcation including the CCA and CB of eight healthy volunteers were scanned in a longitudinal plane with vector flow ultrasound (US) using a commercial vector flow ultrasound scanner (ProFocus, BK Medical, Denmark) with a linear 5 MHz transducer transverse oscillation vector flow software. CCA and CB areas were marked in one cardiac cycle from each volunteer. The complex flow was assessed by medical expert evaluation and by vector concentration calculation. A vortex with complex flow was found in all carotid bulbs, whereas the CCA had mainly laminar flow. The medical experts evaluated the flow to be mainly laminar in the CCA (0.82 ± 0.14) and mainly complex (0.23 ± 0.22) in the CB. Likewise, the estimated vector concentrations in CCA (0.96 ± 0.16) indicated mainly laminar flow and in CB (0.83 ± 0.07) indicated mainly turbulence. Both methods were thus able to clearly distinguish the flow patterns of CCA and CB in systole. Vector concentration from angle-independent vector velocity estimates is a quantitative index, which is simple to calculate and can differentiate between laminar and complex flow.  相似文献   

12.
This paper demonstrates the feasibility of in vivo quantitative mapping of liver viscoelasticity using the concept of supersonic shear wave imaging. This technique is based on the combination of a radiation force induced in tissues by focused ultrasonic beams and a very high frame rate ultrasound imaging sequence capable of catching in real time the transient propagation of resulting shear waves. The local shear wave velocity is recovered using a dedicated time-of-flight estimation technique and enables the 2-D quantitative mapping of shear elasticity. This imaging modality is performed using a conventional ultrasound probe during a standard intercostal ultrasonographic examination. Three supersonic shear imaging (SSI) sequences are applied successively in the left, middle and right parts of the 2-D ultrasonographic image. Resulting shear elasticity images in the three regions are concatenated to provide the final image covering the entire region-of-interest. The ability of the SSI technique to provide a quantitative and local estimation of liver shear modulus with a millimetric resolution is proven in vivo on 15 healthy volunteers. Liver moduli extracted from in vivo data from healthy volunteers are consistent with those reported in the literature (Young's modulus ranging from 4 to 7.5 kPa). Moreover, liver stiffness estimation using the SSI mode is shown to be fast (less than one second), repeatable (5.7% standard deviation) and reproducible (6.7% standard deviation). This technique, used as a complementary tool for B-mode ultrasound, could complement morphologic information both for fibrosis staging and hepatic lesions imaging (E-mail: jl.gennisson@espci.fr).  相似文献   

13.
Vascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 ± 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 ± 16%) and the smallest during mid-diastole (4.3± 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 ± 30% and 24 ± 51%), whereas WSS was overestimated for end-diastolic measurements (?44 ± 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology.  相似文献   

14.
3-D blood vector flow imaging is of great value in understanding and detecting cardiovascular diseases. Currently, 3-D ultrasound vector flow imaging requires 2-D matrix probes, which are expensive and suffer from suboptimal image quality. Our recent study proposed an interpolation algorithm to obtain a divergence-free reconstruction of the 3-D flow field from 2-D velocities obtained by high-frame-rate ultrasound particle imaging velocimetry (High Frame Rate echo-Particle Imaging Velocimetry, also known as HFR Ultrasound Imaging Velocimetry (UIV)), using a 1-D array transducer. The aim of this work was to significantly improve the accuracy and reduce the time-to-solution of our previous approach, thereby paving the way for clinical translation. More specifically, accuracy was improved by optimising the divergence-free basis to reduce Runge phenomena near domain boundaries, and time-to-solution was reduced by demonstrating that under certain conditions, the resulting system could be solved using widely available and highly optimised generalised minimum residual algorithms. To initially illustrate the utility of the approach, coarse 2-D subsamplings of an analytical unsteady Womersely flow solution and a steady helical flow solution obtained using computational fluid dynamics were used successfully to reconstruct full flow solutions, with 0.82% and 4.8% average relative errors in the velocity field, respectively. Subsequently, multiplane 2-D velocity fields were obtained through HFR UIV for a straight-tube phantom and a carotid bifurcation phantom, from which full 3-D flow fields were reconstructed. These were then compared with flow fields obtained via computational fluid dynamics in each of the two configurations, and average relative errors of 6.01% and 12.8% in the velocity field were obtained. These results reflect 15%–75% improvements in accuracy and 53- to 874-fold acceleration of reconstruction speeds for the four cases, compared with the previous divergence-free flow reconstruction method. In conclusion, the proposed method provides an effective and fast method to reconstruct 3-D flow in arteries using a 1-D array transducer.  相似文献   

15.
Volume flow in arteriovenous fistulas for hemodialysis was measured using the angle-independent ultrasound technique Vector Flow Imaging and compared with flow measurements using the ultrasound dilution technique during dialysis. Using an UltraView 800 ultrasound scanner (BK Medical, Herlev, Denmark) with a linear transducer, 20 arteriovenous fistulas were scanned directly on the most superficial part of the fistula just before dialysis. Vector Flow Imaging volume flow was estimated with two different approaches, using the maximum and the average flow velocities detected in the fistula. Flow was estimated to be 242 mL/min and 404 mL/min lower than the ultrasound dilution technique estimate, depending on the approach. The standard deviations of the two Vector Flow Imaging approaches were 175.9 mL/min and 164.8 mL/min compared with a standard deviation of 136.9 mL/min using the ultrasound dilution technique. The study supports that Vector Flow Imaging is applicable for volume flow measurements.  相似文献   

16.
A two-dimensional (2-D) blood velocity estimator is presented combining speckle tracking (ST) and phase-shift estimation (PE) to measure lateral (vx) and axial (vz) velocities respectively. Estimator properties were assessed in a carotid bifurcation using ultrasound simulations based on computational fluid dynamics, allowing validation toward a ground truth. Simulation results were supported with in vivo data of a healthy carotid. ST and PE estimates were combined as: (1) vx from 2D-ST and vz from PE, (2) vx from 2D-ST and vz from PE with aliasing correction based on ST and (3) vz from PE and only lateral ST for vx. Regression analysis showed a 35% to 77% decrease in standard deviation for vz for PE compared with ST. Aliasing correction based on ST improved results but also introduced spurious artifacts. A marginal decrease in performance was observed when only tracking laterally. Further work will focus on in vivo trials in patients with carotid plaques. (E-mail: abigail.swillens@ugent.be)  相似文献   

17.
Noninvasive, easy-to-use and accurate measurements of wall shear stress (WSS) in human blood vessels have always been challenging in clinical applications. Echo particle image velocimetry (Echo PIV) has shown promise for clinical measurements of local hemodynamics and wall shear rate. Thus far, however, the method has only been validated under simple flow conditions. In this study, we validated Echo PIV under in vitro and in vivo conditions. For in vitro validation, we used an anatomically correct, compliant carotid bifurcation flow phantom with pulsatile flow conditions, using optical particle image velocimetry (optical PIV) as the reference standard. For in vivo validation, we compared Echo PIV-derived 2-D velocity fields obtained at the carotid bifurcation in five normal subjects against phase-contrast magnetic resonance imaging (PC-MRI)-derived velocity measurements obtained at the same locations. For both studies, time-dependent, 2-D, two-component velocity vectors; peak/centerline velocity, flow rate and wall shear rate (WSR) waveforms at the common carotid artery (CCA), carotid bifurcation and distal internal carotid artery (ICA) were examined. Linear regression, correlation analysis and Bland-Altman analysis were used to quantify the agreement of different waveforms measured by the two techniques. In vitro results showed that Echo PIV produced good images of time-dependent velocity vector maps over the cardiac cycle with excellent temporal (up to 0.7 ms) and spatial (∼0.5 mm) resolutions and quality, comparable with optical PIV results. Further, good agreement was found between Echo PIV and optical PIV results for velocity and WSR measurements. In vivo results also showed good agreement between Echo PIV velocities and phase contrast MRI velocities. We conclude that Echo PIV provides accurate velocity vector and WSR measurements in the carotid bifurcation and has significant potential as a clinical tool for cardiovascular hemodynamics evaluation. (E-mail: Robin.shandas@ucdenver.edu)  相似文献   

18.
Transvaginal sonography plays an important role in the assessment of the morphology of ovarian lesions. However, the accuracy of the technique is limited due to the significant number of false-positive results. Color Doppler imaging and pulsed Doppler spectral analysis enable evaluation of ovarian tumor blood flow, analysis of the distribution of blood vessels, and quantitative measurement of blood flow velocity waveforms. These parameters increase the sensitivity and specificity of ultrasound evaluation of ovarian tumors. Unfortunately, there is no consensus as to which Doppler parameters and cutoff values are the most predictive of malignancy. Three-dimensional (3-D) power Doppler ultrasound provides a new tool to evaluate features of tumor vascularity. Three-dimensional ultrasound and 3-D power Doppler imaging in patients with “positive” findings on standard ultrasound tests, which encompass annual gray-scale transvaginal sonography followed by transvaginal color Doppler ultrasound in selected cases, represent a novel approach for early and accurate detection of ovarian cancer through screening. Combined evaluations of morphology and neovascularity by 3-D power Doppler ultrasound may improve early detection of ovarian carcinoma. Contrast-enhanced 3-D power Doppler sonography facilitates visualization of adnexal tumor vessels, which may aid in differentiating benign from malignant adnexal lesions.  相似文献   

19.
The aim of the vector Doppler technique is the quantitative reconstruction of a velocity field independently of the ultrasonic probe axis to flow angle. In particular, vector Doppler is interesting for studying vascular pathologies related to complex blood flows. A problem of vector Doppler is data representation in real-time that should be easy to interpret for the physician. In this work, we present a technique for dynamic display of vector velocity maps and some experimental results obtained in vitro with 2-D vector Doppler on flow phantoms reproducing complex flow conditions. An improvement in the map presentation was obtained by using velocity vector field interpolation. In this work, we considered the problem of spatial sampling for vector Doppler, establishing a relationship between sampling steps and scanning system characteristics. Finally, we developed a novel multimedia solution that uses both interpolated images and sound to discriminate between laminar and turbulent flows.  相似文献   

20.
We assess circadian (CD) and circaseptan (CS) changes in the blood pressure (BP) response to a 1–min immersion of the hand into ice water, the cold pressor test (CPT). An about 8 mmHg BP increase in the CPT reported by others for health and an elevation >25 mmHg for patients with “hypertension” have been viewed as predisease, but variables related to the vascular system exhibit prominent CD, CS and circannuals, among other components of their genetically anchored time structure or chronome, and may also have to be considered. Hence, a 16-year-old adolescent (ML) immersed her hand into ice water every 2–4 h for 2 days and once daily in the morning thereafter for 1 week (N = 25), as did, only for <2 days (≥24 h), four adults 20–66 years of age. BP and heart rate (HR) were monitored automatically around the clock at 15–min intervals and at 1–min intervals before and immediately after the CPT. Data were analyzed by cosinor. The difference between the first post-CPT BP value and the mean of the last seven values prior to the CPT was a measure of CPT response (at 1–min). Overall, ML’s systolic (S) BP increased by 8.2 ± 1.4 mmHg and her diastolic (D) BP by 6.2 ± 0.9 mmHg (P < 0.001). Increases were found in 96% of the tests for SBP, 92% for DBP and 20% for HR. There was only one tie for HR (4%), resulting in a HR decrease in 76% of CPTs. The BP response to CPT at 1 min was CS-dependent. The CS double amplitudes are 12.5 ± 4.1 for SBP (P = 0.019) and 7.8 ± 2.8 mmHg for DBP (P = 0.030), with acrophases occurring on late Sunday, early Monday (at –50° and –67° from 00:00 h from Saturday to Sunday for SBP and DBP, respectively, with 360° ≡ 1 week). The response of HR did not allow the detection of a CS rhythm (P = 0.969). The CD response peaked in the early morning hours; with 24 h ≡ 360° and 0° = local midnight, the acrophase (φ) for SBP is at –80° and for DBP at –113°, in keeping with earlier results from four adult subjects (SBP: –37°; DBP: –42°), individual differences notwithstanding. The average timing of the largest overall response of BP to CPT coincides with the timing of the response to other stimuli. The CS acrophases coincide with the times of increased morbidity/mortality from vascular diseases. Chronomes, time structures broader than circadian, notably their about-weekly components, should be considered, not only at the extremes of life when the CS and about-half-weekly rhythms are particularly prominent in BP and HR but also in interpreting BP responses as a gauge of vascular disease status in adolescents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号