INTRODUCTION

Floseal® (Baxter, Hayward, CA, US) can be of value in reducing blood loss and haematoma rates. The manufacturer’s warnings include allergic reaction, poor wound healing and intravascular thrombosis. We aimed to determine whether Floseal® is safe to use in various head and neck surgery (HNS) procedures.

METHODS

A prospective trial was conducted using Floseal® in 42 various consecutive head and neck surgery procedures. Adverse incidents were used as the main outcome measure, including allergic reaction, wound breakdown, wound infection and thrombosis. Secondary outcome measures included haematoma formation, hospital stay, drain times and output.

RESULTS

No adverse incidents were recorded in the trial period. Two patients developed haematomas and required surgical exploration where a bleeding vessel was identified and dealt with.

CONCLUSIONS

Floseal® is safe to be used in head and neck surgery with no adverse effects. A larger number and a control group are required to ascertain its value in reducing blood loss, haematoma formation, drain usage and hospital stay.  相似文献   

2.

Purpose

This study aimed to propose a technique to quantify dynamic hip screw (DHS®) migration on serial anteroposterior (AP) radiographs by accounting for femoral rotation and flexion.

Methods

Femoral rotation and flexion were estimated using radiographic projections of the DHS® plate thickness and length, respectively. The method accuracy was evaluated using a synthetic femur fixed with a DHS® and positioned at pre-defined rotation and flexion settings. Standardised measurements of DHS® migration were trigonometrically adjusted for femoral rotation and flexion, and compared with unadjusted estimates in 34 patients.

Results

The mean difference between the estimated and true femoral rotation and flexion values was 1.3° (95 % CI 0.9–1.7°) and −3.0° (95 % CI – 4.2° to −1.9°), respectively. Adjusted measurements of DHS® migration were significantly larger than unadjusted measurements (p = 0.045).

Conclusion

The presented method allows quantification of DHS® migration with adequate bias correction due to femoral rotation and flexion.

Electronic supplementary material

The online version of this article (doi:10.1007/s00264-013-2146-4) contains supplementary material, which is available to authorised users.  相似文献   

3.

INTRODUCTION

Laparoscopic cholecystectomy has many complications which may be seen due to anatomical variations, lack of experience of the surgeon or three dimensional visualization, or insufficient exposure of the surgical field; including vascular injuries. Here we present a case of pseudoaneurysm of the right hepatic artery leading to hemobilia after rupturing into the biliary system.

PRESENTATION OF CASE

A 43-year-old male patient presented to our clinic 3 weeks post laparoscopic cholecystectomy with right upper quadrant pain, melena and hematemesis. After stabilizing the patient, Doppler ultrasonography, abdominal computer tomography and selective right hepatic artery angiography were performed and a pseudoaneurysm was established on the anterior posterior bifurcation of right hepatic artery. Right hepatic artery ligation and a T-tube placement after choledocotomy were performed. The patient recovered completely.

DISCUSSION

Pseudoaneurysms of the hepatic artery may arise as a complication of laparoscopic cholecystectomy. Clip encroachments, mechanical or thermal injury during the procedure are likely to be precipitating factors. Today, transarterial embolization (TAE) is the gold standard for the management of hemobilia, and if it fails, the next step in management is surgical. Surgery is limited to extra-hepatic or gallbladder bleeding, and for TAE failure.

CONCLUSION

In cases of GI bleeding the awareness of the surgeon should be drawn to a clinical suspicion of hemobilia and an underlying hepatic artery pseudoaneurysm that can arise as a complication. CT angiography should be performed for early diagnosis and management in such patients.  相似文献   

4.

Introduction

There are few reports of injury to the soft palate and retropharynx sustained during intubation with the GlideScope® video laryngoscope. Most reports are of isolated injury to the soft palate.

Case History

We describe a patient in whom the retropharynx was injured but the extent of the injury was not observed initially. The patient did not suffer severe sequelae from this injury. However, this injury can cause serious sequelae if it is not recognised (eg development of a retropharyngeal abscess).

Conclusions

We recommend that any patient who sustains injury to the soft palate during intubation (particularly if the endotracheal tube passes through the soft palate) should be reviewed an otolaryngologist before removal of the endotracheal tube.  相似文献   

5.
6.
7.

Objective:

This report describes chiropractic management of a case of sub-acute elbow pain and swelling with Active Release Technique® and acupuncture.

Case presentation:

A 41-year-old male presented to a chiropractic clinic with a primary complaint of elbow pain and swelling following a fall while playing basketball five weeks prior.

Intervention and Outcome:

Treatment consisted of two sessions of needle acupuncture and one treatment of Active Release Techniques® (ART) applied to the left elbow region.

Conclusions:

The patient’s outcomes indicated a quick resolution of subjective complaints and objective findings with the chosen treatment. Further research is needed to demonstrate safety, clinical effectiveness, and cost effectiveness when compared to other treatments.  相似文献   

8.
9.

Introduction

Presacral venous bleeding is an uncommon but potentially life threatening complication of rectal surgery. During the posterior rectal dissection, it is recommended to proceed into the plane between the fascia propria of the rectum and the presacral fascia. Incorrect mobilisation of the rectum outside the Waldeyer’s fascia can tear out the lower presacral venous plexus or the sacral basivertebral veins, causing what may prove to be uncontrollable bleeding.

Methods

A systematic search of the MEDLINE® and Embase™ databases was performed to obtain primary data published in the period between 1 January 1960 and 31 July 2013. Each article describing variables such as incidence of presacral venous bleeding, surgical approach, number of cases treated and success rate was included in the analysis.

Results

A number of creative solutions have been described that attempt to provide good tamponade of the presacral haemorrhage, eliminating the need for second operation. However, few cases are reported in the literature.

Conclusions

As conventional haemostatic measures often fail to control this type of haemorrhage, several alternative methods to control bleeding definitively have been described. We propose a practical comprehensive classification of the available techniques for the management of presacral bleeding.  相似文献   

10.

Purpose

After clinical introduction of the Fitmore® stem (Zimmer), we noticed the formation of cortical hypertrophies in a few cases. We questioned whether (1) the primary stability or (2) load transfer of the Fitmore® stem differs from other stems unassociated with the formation of hypertrophies. We compared the Fitmore® stem to the well-established CLS® stem.

Methods

Four Fitmore® and four CLS® stems were implanted in eight synthetic femurs. A cyclic torque around the stem axis and a mediolateral cyclic torque were applied. Micromotions between stems and femurs were measured to classify the specific rotational implant stability and to analyse the bending behaviour of the stem.

Results

No statistical differences were found between the two stem designs with respect to their rotational stability (p = 0.82). For both stems, a proximal fixation was found. However, for the mediolateral bending behavior, we observed a significantly (p < 0.01) higher flexibility of the CLS® stem compared to the Fitmore® stem.

Conclusion

Hip stem implantation may induce remodelling of the periprosthetic bone structure. Considering the proximal fixation of both stems, rotational stability of the Fitmore® stem might not be a plausible explanation for clinically observed formation of hypertrophies. However, bending results support our hypothesis that the CLS® stem presumably closely follows the bending of the bone, whereas the shorter Fitmore® stem acts more rigidly. Stem rigidity and flexibility needs to be considered, as they may influence the load transfer at the implant–bone interface and thus possibly affect bone remodelling processes.  相似文献   

11.

Background

Multiple radiographic parameters used for diagnosis and quantification of morphologic pincer features have emerged, but the degree to which pelvic tilt or rotation affects conventional radiography and EOS® is unknown.

Question/purposes

We asked: (1) What is the reliability of EOS® and conventional radiography at increasing sizes of morphologic pincer features with varying degrees of tilt and rotation? (2) What is the effect of tilt and rotation on acetabular overcoverage measurements?

Methods

Using a dry cadaveric pelvis, AP conventional radiographs and EOS® images were taken at intervals of increasing modeled pincer size with 0° to 15° varying tilt and rotation. Lateral center-edge angle, Sharp angle, Tönnis angle, crossover sign, and retroversion index were measured on all images. Statistical analysis was conducted.

Results

The intermodality intraclass correlation coefficients for conventional radiography and EOS® radiography across all pincer sizes, rotations, and tilts were excellent (0.93–0.98). Crossover sign was in perfect agreement in conventional radiography and EOS®. Rotation of the hip away from the beam source and/or increased anterior tilt falsely increased all overcoverage parameters except for Tönnis angle. Rotation away from the beam of 10°or greater or anterior tilt of 5° or greater produced a false-positive crossover sign.

Conclusions

EOS® radiography maintained excellent reliability in comparison to conventional radiography but both were equally vulnerable to the effects of tilt and rotation for quantification of hip parameters used in acetabular overcoverage assessment. A standardized pelvic radiograph ensuring that the pelvis is not excessively tilted or rotated should be used for assessing acetabular overcoverage parameters.  相似文献   

12.

Objective:

To describe a case of chronic Little Leaguer’s Shoulder in reference to pain presentation, physical capabilities, and recovery time.

Clinical Features:

A 17-year-old, junior baseball pitcher presented with shoulder pain when performing high velocity pitching. Conservative treatment for an assumed soft tissue injury failed to resolve the pain, which was regularly aggravated by pitching, and which subsequently prompted further evaluation, and eventual confirmation of Little Leaguer’s Shoulder on subsequent computerized tomography (CT) imaging.

Intervention and Outcome:

Prior to proper diagnosis, conservative treatment had consisted of activity modification, spinal adjusting, laser therapy, shockwave therapy, Active Release Techniques®, Kinesiotape,® and rehabilitation. Later, rehabilitation, consisting of general muscle and core strengthening, continued for a further six months under the supervision of college athletic trainers. The athlete was able to return to normal pitching duties approximately 12 months later.

Summary:

In this case, a potentially damaging bone injury masquerading as a simple musculo-tendinous injury created a diagnostic challenge. The patient eventually recovered with rest, time, strengthening, and eventual compliance to prescribed activity modification.  相似文献   

13.

Purpose

Limited data exist for the reconstructive potential of short bone-preserving stems in THA using a minimal invasive posterolateral approach. Our study aim was to assess the effect of stem design on the reconstruction of hip offset and leg length in MIS posterolateral THA.

Methods

This retrospective consecutive single-surgeon study compares hip offset and leg length, as well as acetabular component positioning (cup anteversion; inclination) of 129 THAs with a cementless standard-length stem (Synergy®) and 143 THAs with a cementless short bone-preserving stem (Trilock®).

Results

In reference to the contralateral side, the mean difference in hip offset was 0.9 mm (p = 0.067) for the standard stem and 0.1 mm (p = 0.793) for the short stem, respectively. Leg-length discrepancy was 0.7 mm (Synergy®) and 0.9 mm (Trilock®), respectively. A total of 233 (86 %) acetabular components fell within the target zone for anteversion and inclination.

Conclusion

Accurate component positioning in MIS posterolateral approach THA is possible and is not influenced by the type of stem.  相似文献   

14.
15.

Background

Caustic burns are burns of third and fourth degree caused by strong acids or strong bases. Muriatic acid is often used for suicidal attempt by ingestion. We describe a case of a caustic skin lesion caused by intravenous failed attempt of suicide by injection of Muriatic acid in a woman affected with bipolar-syndrome. Generally, caustic burns are treated by cleansing, escarectomy and coverage with skin grafts.

Case report

We treated the patient with a non invasive technique with collagenase and hyaluronic acid sodium salt cream (Bionect start®), hyaluronic acid-based matrix (Hyalomatrix®) and Vacuum-Assisted Closure (VAC) Therapy®.

Results

We obtained complete healing in 6 weeks.

Conclusions

Combined use of non invasive techniques seems to ensure only advantages for both the patients and the Health System. It reduces health care costs and risks for the patients such as nosocomial infections. Patient’s compliance is high, as its quality of life. Complete healing of the wound is fast and recovery of function is full.  相似文献   

16.
17.

Background:

Intrahepatic arterial aneurysms are rare and typically related to trauma, transplantation, iatrogenic injury, or infection. They account for approximately 10% of clinically significant hemobilia.

Case Report:

We present the case of a 49-year-old man with an intraparenchymal hepatic artery aneurysm that presented as massive hemobilia following a laparoscopic cholecystectomy. The aneurysm could not be managed by interventional embolization and required a left hepatic lobectomy, which was performed laparoscopically.

Discussion:

Evaluation of hemobilia requires a multidisciplinary team approach. The diagnosis of hepatic artery aneurysm can be most readily made by MRI or CT scan. Interventional embolization of the aneurysm may be effective treatment but is not always possible due to anatomic considerations. Where indicated, surgical resection in a manner that preserves a maximal amount of normal hepatic parenchyma is the treatment of choice.

Conclusion:

This is the first report of laparoscopic liver resection performed for bleeding from a hepatic artery aneurysm and adds an effective treatment modality to the surgical armamentarium.  相似文献   

18.

Introduction

Retained sponges and instruments (RSI) due to surgery are a recognised medical ‘never event’ and have catastrophic implications for patients, healthcare professionals and medical care providers. The aim of this review was to elucidate the extent of the problem of RSI and to identify preventative strategies.

Methods

A comprehensive literature search was performed on MEDLINE®, Embase™, the Science Citation Index and Google™ Scholar for articles published in English between January 2000 and June 2012. Studies outlining the incidence, risk, management and attempts to prevent RSI following surgical intervention were retrieved.

Results

The overall incidence of RSI is low although its incidence is substantially higher in operations performed on open cavities. Sponges are the most commonly retained item when compared with needles and instruments. Clinical presentation is varied, leading to avoidable morbidity, and the error is indefensible medicolegally. Risk factors include emergency operations, operations involving unexpected change in procedure, raised body mass index, and a failure to perform accurate sponge and instrument counts. The existing strategy for prevention is manual counting of sponges and instruments undertaken by surgical personnel. This, however, is fallible. Computer assisted counting of sponges using barcodes and gauze sponges tagged with a radiofrequency identification device aiding manual counting have been trialled recently, with success.

Conclusions

Vigilance among operating theatre personnel is paramount if RSI is to be prevented. Prospective multicentre trials to assess efficacy of new technologies aiding manual counting should be undertaken if this medical error is to be eliminated completely.  相似文献   

19.

Objective

To describe the subjective pain and functional improvements of a patient with chronic Achilles tendinopathy following a treatment plan incorporating active and passive tissue warm-up, followed respectively by soft tissue mobilization utilizing both Graston Technique® and Active Release Techniques®, eccentric exercise, and static stretching in combination with cryotherapy.

Background

The primary characterization of chronic Achilles tendinopathy is gradual onset of pain and dysfunction focused in one or both Achilles tendons arising secondary to a history of repetitive use or excessive overload.

Intervention and Outcome

Conservative treatment is commonly the initial strategy for patient management. Tissue heating, soft tissue mobilization, eccentric training, and static stretching with cryotherapy were implemented to reduce pain and improve function.

Summary

A specific protocol of heat, soft tissue mobilization, eccentric exercise, stretching, and cryotherapy appeared to facilitate a rapid and complete recovery from chronic Achilles tendinopathy.  相似文献   

20.

Objective

To identify outcomes of participation, life satisfaction, and medical complications as a function of impairment in adults with pediatric-onset spinal cord injury (SCI).

Methods

Study participants were adults who sustained SCI at age 18 years or younger and were interviewed at age 24 years or older (M = 26.9, SD = 3.5). The telephone interview included a questionnaire and several standardized measures: FIM® instrument (FIM®), Craig Handicap Assessment and Reporting Technique (CHART), SF-12® Health Survey, and Satisfaction with Life Scale. Using the International Standards for Neurological Classification of Spinal Cord Injury and the American Spinal Injury Association (ASIA) Impairment Scale (AIS), subjects were grouped into four impairment categories: C1–C4 ABC, C5–C8 ABC, T1–L4 ABC, and AIS D.

Results

Of the 410 participants, 62% were male, 54% had tetraplegia, 70% had AIS A lesions, and average age at injury was 14 years (SD = 4.3). Of the 407 subjects who had complete neurological information, 59 had C1–C4 ABC, 140 had C5–C8 ABC, 168 had T1–L4 ABC, and 40 had AIS D lesions. The outcomes were delineated for education, employment, independent living and driving, marriage, participation, medical complications, health-related quality of life, and global life satisfaction, in addition to the ASIA motor score and FIM® motor scores, for each of the four impairment groups.

Conclusions

This information should help focus interventions that facilitate positive outcomes in relationship to the severity of impairment. In addition, these data can provide a level of expectation about long-term outcomes for newly injured children and their parents.  相似文献   