首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A newly marketed rapid agglutination kit for the identification of Staphylococcus aureus, Slidex Staph Plus (bioMérieux), was compared to Staphaurex Plus (Murex Diagnostics) and Pastorex Staph-Plus (Sanofi Diagnostics Pasteur). The study took place in three clinical microbiology laboratories in three different European countries. A total of 892 staphylococcal isolates, including 278 methicillin-sensitive S. aureus (MSSA) isolates, 171 methicillin-resistant S. aureus (MRSA) isolates, and 443 coagulase-negative staphylococcal isolates, were analyzed. The sensitivities (MSSA/MRSA) and specificities, respectively, were 98. 2% (98.9%/97.1%) and 98.9% for Slidex Staph Plus, 98.2% (98.2%/98. 2%) and 96.2% for Staphaurex Plus, and 98.7% (98.6%/98.8%) and 95.7% for Pastorex Staph Plus. The specificity of the Slidex Staph Plus kit was statistically significantly higher than the specificities of Staphaurex Plus and Pastorex Staph-Plus. The Slidex Staph Plus is a very reliable test for the identification of S. aureus.  相似文献   

2.
The performance of a second-generation rapid agglutination kit, Slidex Staph Plus (SSP; bioMérieux), was compared to those of the Slidex Staph (SS; bioMérieux), Staphaurex (SRX; Murex Diagnostics), and BBL Staphyloslide (BBL; Becton Dickinson) kits by using 508 clinical isolates composed of 150 methicillin-sensitive Staphylococcus aureus (MSSA) organisms, 154 methicillin-resistant S. aureus (MRSA) organisms, and 204 non-S. aureus Staphylococcus spp. Of the 508 isolates tested, 75% were fresh clinical isolates, with the remainder taken from five different freezer collections. All four agglutination tests had comparable sensitivities for MSSA and MRSA. However, the SS kit was significantly less specific (93.1%) than the three other tests (P > 0.05, McNemar test). These results demonstrate that the new rapid latex agglutination kit, SSP, was more specific for the identification of S. aureus than the previous version and performed comparably to the SRX and BBL kits.  相似文献   

3.
Four commercially available slide agglutination systems for identifying Staphylococcus aureus were compared with the conventional slide (clumping factor) and tube coagulase tests. The systems evaluated included Bacto Staph Latex (Difco Laboratories, Detroit, Mich.), Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.), Mini ID Accu-Staph (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.), and Staphaurex (Wellcome Diagnostics, Research Triangle Park, N.C.). A total of 338 clinical isolates, including methicillin-resistant S. aureus (n = 149), methicillin-susceptible S. aureus (n = 78), methicillin-resistant, coagulase-negative staphylococci (n = 45), and methicillin-susceptible, coagulase-negative staphylococci (n = 66), were tested by each method. The slide test for clumping factor, the 4-h tube coagulase test, Bacto Staph Latex, Staphyloslide, Mini ID Accu-Staph, and Staphaurex detected 212 (93.4%), 218 (96%), 223 (98.2%), 223 (98.2%), 221 (97.4%), and 224 (98.7%) of the S. aureus (44% methicillin-resistant) isolates, respectively. There were no false-positive results with any of the methods when the 111 strains of coagulase-negative staphylococci were tested. The results of this evaluation suggest that the four slide identification methods tested can provide rapid and accurate identification of methicillin-resistant S. aureus strains.  相似文献   

4.
Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.  相似文献   

5.
Five different laboratory tests for the identification of Staphylococcus aureus were compared. Analyses of 271 presumptive S. aureus strains, supplemented with 59 well-defined methicillin-resistant S. aureus (MRSA) isolates, were performed. Only the Staphaurex Plus (Murex Diagnostics, Dartford, United Kingdom) and the Pastorex Staphplus (Sanofi, Marnes-La-Coquette, France) tests displayed 100% sensitivity. The observed difference with the free-coagulase test (Bacto coagulase plasma; Difco, Detroit, Mich.), a bound-coagulase (clumping factor) test, and the former Staphaurex test (Murex Diagnostics) was caused mainly by the inability of these three tests to identify some MRSA strains correctly. Among Polish MRSA isolates included in the analysis, a group of free-coagulase-negative S. aureus strains was detected. Genetic typing by random amplification of polymorphic DNA revealed that the strains showing aberrant behavior when the different test results were compared belonged to limited number of S. aureus clones.  相似文献   

6.
Six commercial agglutination tests designed for the identification of Staphylococcus aureus were compared by using a strain collection which included 512 staphylococci representing 33 species (318 isolates of Staphylococcus aureus [including 144 oxacillin resistant], 46 S. epidermidis isolates, 15 S. haemolyticus isolates, 12 S. saprophyticus isolates, 29 S. schleiferi isolates, 30 S. lugdunensis isolates, and 62 other coagulase-negative staphylococci). This group also included a proportion of strains with unusual phenotypes (e.g., 19 coagulase-negative S. aureus isolates, 26 clumping factor-negative S. aureus isolates, and 4 S. aureus isolates each with a double deficiency). The overall sensitivity for identification of typical and atypical S. aureus was high with the Staphaurex Plus test (Murex Biotech) (99.7%), the Pastorex Staph Plus test (Sanofi Diagnostics Pasteur) (99.7%), and the Slidex Staph Plus test (bioMérieux) (100%). The overall rate of specificity was affected by the unusual inclusion in this study of a high proportion of non-S. aureus species, such as S. lugdunensis and S. schleiferi, which express a clumping factor and therefore produce a positive result with the agglutination tests.  相似文献   

7.
Several commercial systems are available to distinguish between Staphylococcus aureus and the coagulase-negative species of the Micrococcaceae family. Four latex agglutination systems (Accu-Staph, SeroSTAT, Staphaurex, and Staphylatex) and two hemagglutination systems (Hemastaph and Staphyloslide) were compared for their performance in the rapid identification of 232 isolates of staphylococci, including 114 of methicillin-resistant S. aureus. Accu-Staph, Staphaurex, and Staphyloslide correctly identified 100% of the methicillin-resistant S. aureus isolates; Hemastaph and Staphylatex, 99.1%; and SeroSTAT, 94.7%. Most reactions were easy to interpret, although 15% of the SeroSTAT reactions were weak. Autoagglutination occurred only with isolates of coagulase-negative staphylococci. False-positive reactions were rare and occurred only with systems which did not detect autoagglutination. Five of these six systems appear to be adequate for the rapid identification of S. aureus, including methicillin-resistant isolates.  相似文献   

8.
Comparison of rapid identification assays for Staphylococcus aureus.   总被引:1,自引:15,他引:1       下载免费PDF全文
A total of 137 strains of Staphylococcus species were blindly tested by four rapid serological assays, and the results were compared with those of the tube coagulase assay. For the S. aureus isolates, the Sero-STAT Staph assay gave six false-negative results, four of which were for methicillin-resistant strains. The Accu -Staph, Staphylatex , and Staphyloslide assays identified all the coagulase-positive strains as Staphylococcus aureus. Among the coagulase-negative staphylococci, false-positive results were seen with strains of S. capitis. S. saprophyticus, and S. cohnii. The overall accuracy of the kits compared with the tube coagulase test ranged from 95.1 to 100%.  相似文献   

9.
A total of 272 staphylococcal isolates from cases of bovine mastitis (159 Staphylococcus aureus) belonging to 12 different species were identified with ID32 STAPH galleries, and 51 of them were confirmed by 16S rRNA gene (rrs) sequencing. The same isolates were examined for their hemolytic activity on sheep blood agar, DNase activity, and coagulase activity and with two rapid identification kits (Slidex Staph Plus kit and RAPIDEC Staph from Bio-Merieux). The results of this study confirm those obtained by other groups with hemolysis, DNase, and coagulase. Only 50% of S. aureus isolates from mastitis cases show coagulase activity after 4 h of incubation, and a 24-h incubation is necessary for the full sensitivity of this test. In contrast to results from other studies with human isolates, the Slidex Staph Plus kit was not sensitive enough for the identification of S. aureus from bovine mastitis samples. The aurease test of the RAPIDEC Staph kit showed 100% sensitivity and 100% specificity. Used in conjunction with hemolysis patterns, the RAPIDEC Staph kit is therefore very well adapted to rapid, efficient, and cost-effective identification of S. aureus in cultures from bovine mastitis samples. Sequencing of rrs genes also proved very efficient in identifying the Staphylococcus species encountered in these samples and confirming phenotypical identification results with unsatisfactory scores. With continuously improving technologies and decreasing costs, genetic identification methods like rrs gene sequencing will soon find a place in routine veterinary diagnostics.  相似文献   

10.
 In this study, we evaluated a fourth-generation agglutination assay (Staph Plus; DiaMondiaL[DML]) for the rapid identification of Staphylococcus aureus. First, comparison with three third-generation assays (Slidex Staph Plus, bioMérieux; Staphaurex Plus, Murex Diagnostics; Pastorex Staph-Plus, Sanofi Diagnostics Pasteur) was performed on a predefined strain collection: 265 coagulase-negative staphylococci (CNS), 266 methicillin-resistant S. aureus (MRSA) and 262 methicillin-susceptible S. aureus (MSSA) strains (“strain study”). Second, patient material-derived strains (883 CNS, 847 MSSA and 135 MRSA) were tested concurrently with both the DML and Slidex assays (“daily practice study”). In the strain study, the overall sensitivity and specificity of the DML, Slidex, Staphaurex and Pastorex assays were 99.2% and 100%, 98.1% and 100%, 95.2% and 100%, and 98.2% and 98.8%, respectively. Using the respective tests, the result was indeterminate in 0.0%, 0.6%, 0.4% and 1.5% of the strains. Overall, the sensitivity of the DML and Slidex assays were comparable in both sub-studies. However, in MRSA strains, the sensitivity of the DML assay was significantly lower than the Slidex assay. The specificity of the Slidex assay was significantly higher than the DML assay. However, the percentage of indeterminate results was much higher for the Slidex than the DML assay. In conclusion, the presumptive identification of S. aureus by the DML assay proved to be equal to third-generation latex agglutination assays.  相似文献   

11.
We compared the performance of Staphychrom II (International Microbio, Signes, France), a rapid (2-h) chromogenic staphylocoagulase test that uses human prothrombin and protease inhibitors, with those of the reference tube coagulase test (TCT) and the latex agglutination test (LAT) Slidex Staph Plus for the rapid identification of S. aureus. Prospective evaluation with 293 fresh clinical isolates yielded sensitivities, specificities, and predictive and negative predictive values of 98.1, 100, 100, and 95.1%, respectively, for the Staphychrom II test; 98.6, 98.7, 99.6, and 96.3%, respectively, for LAT; and 97.6, 98.7, 99.5, and 93.9%, respectively, for TCT. The perfect specificity of the Staphychrom II test was confirmed by testing 193 collection strains selected because of their potential testing pitfalls. The Staphychrom II test was positive for 90% of the 215 S. aureus strains tested after only 1 h of incubation. The Staphychrom II test was as sensitive as the reference TCT and was 100% specific.  相似文献   

12.
AIMS: To evaluate the BBL Crystal MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus. METHODS: 52 methicillin resistant S aureus (MRSA) from five different countries and 85 methicillin susceptible S aureus (MSSA) were included. The species was confirmed by tube coagulation and detection of the clumping factor using the Staphaurex Plus. Clonal non-identity of the MRSA isolates was shown by pulsed field gel electrophoresis. MIC values (oxacillin) were determined using the Etest. Polymerase chain reaction was carried out to detect the mecA gene. The BBL Crystal MRSA ID System was carried out according to the manufacturer's instructions. RESULTS: The BBL Crystal MRSA ID System showed fluorescence in 45 of 52 MRSA (sensitivity 86.5%; negative predicitive value 92.2%), and the specificity was 97.6% (positive predicitive value 95.7%). Two of seven MRSA that failed to show fluorescence had MIC values (oxacillin) of 4 mg/litre. CONCLUSIONS: The BBL Crystal MRSA ID System is a valuable test for detecting oxacillin resistance in S aureus. Its major advantage is the short time (4-5 hours) required to perform the test when organisms are grown on tryptic soy agar or sheep blood agar. Difficulties may arise in borderline resistant isolates.  相似文献   

13.
A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aureus. A total of 380 clinical strains of staphylococci were tested. The TC test performed at room temperature yielded the largest number of TC-positive results (n = 239), and based on this observation 239 organisms were classified as S. aureus and 141 were classified as non-S. aureus. The SC, TC (37 degrees C), SeroSTAT Staph, Staphyloslide, and Hemastaph tests correctly identified 210 (87.9%), 221 (92.5%), 238 (99.6%), 239 (100%), and 236 (98.7%) of the S. aureus isolates, respectively. Of the S. aureus isolates that were TC positive at room temperature 68% required 24 h of incubation before coagulase production was detected. There was one false-negative SeroSTAT Staph result and one false-negative Hemastaph result. The Staphyloslide test yielded two noninterpretable results (both organisms were later confirmed as non-S. aureus), whereas there were six noninterpretable results recorded with the Hemastaph test (four organisms were classified as non-S. aureus, and two were classified as S. aureus). The SeroSTAT Staph, Staphyloslide, and Hemastaph tests were all more sensitive than the conventional SC and TC (37 degrees C) tests and were considerably more rapid than the TC test at either temperature.  相似文献   

14.
Five commercial Staphylococcus aureus identification kits--Staphaurex (Wellcome), Staphylase (Oxoid), Staphyslide (bioMèrieux), Biostaph (Medlabs) and Bacto Latex (Difco)--were evaluated for the routine identification of S aureus from primary plates in the routine microbiology laboratory. Comparison was made with two methods of tube coagulase testing and five slide methods for detecting clumping factor (slide coagulase testing). Performances were assessed for two groups of organisms, staphylococcal species alone and a combined staphylococcal and non-staphylococcal species group. The effects of growth on selective media and storage of isolates at room temperature and 4 degrees C were investigated. Selective media cannot be recommended, nor can storage of isolates before testing. Ranked according to efficiency value with the combined staphylococcal and non-staphylococcal species group, the kits and coagulase methods performed as follows (the figures in parentheses are the efficiency values for the staphylococcal group alone): tube coagulase reference method 100% (100%), tube coagulase SJH method 99% (99%), Staphaurex 94% (97%), Staphylase 93% (96%), slide coagulase method No 4 93% (94%), slide coagulase method No 5 93% (93%), Bacto Latex 92% (95%), Staphyslide 92% (95%), and Biostaph 87% (91%). It is concluded that a commercial S aureus identification kit should not replace tube coagulase testing for the routine identification of the organism from primary plates and that, even the kits with the best performances, have little advantage over a good slide coagulase test method.  相似文献   

15.
A new commercial yellow latex agglutination reagent (Bacto-Staph) was compared with the slide and tube coagulase tests and three other commercial reagents for the identification of 283 Staphylococcus aureus and 54 non-S. aureus staphylococcal strains. Test sensitivities for the identification of S. aureus were as follows: tube coagulase, 99.6%; slide coagulase, 98.6%; Bacto-Staph, 99.6%; Staphylatex, 98.6%; Sero STAT Staph, 98.2%; and Staphyloslide, 97.5%. No false-positive reactions were observed with any of the commercial reagents.  相似文献   

16.
Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compared with the conventional slide coagulase, tube coagulase (TC), and thermonuclease (TNase) tests for the identification of Staphylococcus aureus. A total of 118 clinical isolates of S. aureus (52 methicillin resistant), 50 S. epidermidis, 5 S. capitis, 2 S. hominis, 3 S. simulans, 6 S. saprophyticus, and 2 S. warneri were tested. The slide coagulase, TC and TNase tests detected 115 (97.5%), 117 (99.2%), and 118 (100%) of the S. aureus isolates, respectively. All showed 100% specificity. The StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph assays correctly identified 117 (99.2%), 117 (99.2%), 116 (98.3%), 110 (93.2%), 108 (91.5%), and 107 (90.7%) of the S. aureus isolates, respectively. For methicillin-resistant S. aureus isolates, StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph showed 1 (2%), 1 (2%), 2 (4%), 7 (13.5%), 7 (13.5%), and 8 (15.4%) false-negative results, respectively. All the commercial agglutination assays demonstrated false-positive results with strains of S. capitis, S. saprophyticus and S. warneri. The overall accuracy of the commercial agglutination assays compared with TC and TNase ranged from 90.7 to 99.2%. We recommend that negative reactions with the rapid commercial test kits for methicillin-resistant Staphylococcus isolates be confirmed with the TC or TNase test.  相似文献   

17.
The performance of a recently introducedStaphylococcus aureus identification system (Slidex Staph-Kit) was compared with that of currently available systems (Immuno Scan Staphlatex, Staphyloslide, Staphaurex and SeroSTAT II) for the identification of methicillin-resistantStaphylococcus aureus (MRSA) and methicillin-susceptibleStaphylococcus aureus. The new system, which detects a capsular antigen common in MRSA, performed with equal or greater sensitivity than the other systems. None of the commercial systems was adversely affected by the methicillin susceptibility of the staphylococci when isolates were recovered from non-selective media. The greatest advantage of the anti-capsular monoclonal reagent was its improved performance on isolates recovered from selective media.  相似文献   

18.
Eighty clinical specimens of BACTEC 9240 blood culture vials, culture positive for staphylococci (38 Staphylococcus aureus and 42 coagulase negative staphylococci), were tested directly for the presence of clumping factor/protein A and free coagulase. Seven commercial slide agglutination kits were compared with a direct-tube coagulase (DTC) method. All tests were performed on blood culture pellets. Sensitivity, specificity, and negative and positive predictive values for the seven commercial kits were extremely variable, whereas a two-hour DTC test was highly predictive of S aureus. There was no significant difference between a two-, six- or 24-hour DTC test. Three (8%) S aureus isolates remained DTC negative even after 24 hours' incubation. Staphylococcal slide agglutination kits should not be used directly on blood culture broths. In contrast, a two-hour DTC test is a useful, rapid screening test for S aureus bacteraemia, provided isolates from DTC negative blood culture broths are re-tested using standard laboratory techniques.  相似文献   

19.
This study evaluated the reliability of the latex slide agglutination test for identifying Staphylococcus aureus. A total of 806 clinical isolates of staphylococci were tested for latex agglutination, clumping factor, and free coagulase. Positive latex tests occurred in 98.3% of coagulase-positive strains, whereas 99.6% of coagulase-negative strains gave negative latex tests. It is concluded that in most instances, the latex slide agglutination test is a reliable method for identifying S. aureus in the clinical laboratory.  相似文献   

20.
Fifty methicillin-resistant Staphylococcus aureus (MRSA) initial isolates obtained from patients hospitalized in the orthopedic clinic of the Frankfurt University Hospital and 150 methicillin-sensitive Staphylococcus aureus (MSSA) isolates were investigated in this study to determine whether the Slidex Staph-Kit is capable of differentiating between MRSA and MSSA owing to its unique performance characteristics. The Slidex Staph-Kit is a combined latex hemagglutination test designed to detect clumping factor, protein A, and a specific surface immunogen for S. aureus. Clumping factor-positive strains cause erythrocytes sensitized with fibrinogen to hemagglutinate, thereby resulting in visible red clumps. S. aureus strains deficient in clumping factor agglutinate latex particles sensitized with specific antibodies against surface proteins of S. aureus, thereby resulting in visible white clumps. Our results demonstrate that white clumping has a 99% specificity as well as a 98% positive predictive value for MRSA. Clumping factor-negative MRSA, which have been reported to occur in several countries, are epidemic in the Frankfurt area and account for 80% of all MRSA initial isolates in the orthopedic clinic of the Frankfurt University Hospital. Genotyping of all MRSA isolates by macrorestriction analysis of chromosomal DNA revealed that 83% of clumping factor-negative MRSA are closely related to the “southern-German” epidemic strain. This is the first study demonstrating the Slidex Staph-Kit’s capability for identifying epidemic clumping factor-negative S. aureus strains as methicillin resistant even prior to antimicrobial susceptibility testing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号