首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An immunochromatographic test for rapid detection of IgM antibodies in patients with acute hepatitis E infection was developed utilizing the well-characterized recombinant protein EP2.1 and monoclonal antibody 4B2. The new rapid test based on a novel reverse-flow technology was able to generate a positive result within 2 to 3 min. Our study showed that this test was able to detect anti-HEV IgM antibodies in 96.7% of the patient samples tested (n = 151) while maintaining an excellent specificity of 98.6% with samples from various patient or healthy control groups (total n = 208). Furthermore, this rapid test gave a good specificity of 90.9% when tested with rheumatoid factor (RF)-positive sera (RF value of < or =850 IU/ml; n = 11) although a higher concentration of RF in samples might cause cross-reactivity. The new test has a good agreement of 97.2% with a kappa value of 0.943 when compared with a reference enzyme-linked immunosorbent assay. The positive predictive value and the negative predictive value for the rapid test thus reached 98.0 and 97.6%, respectively. This is the first rapid, point-of-care test for hepatitis E and will be especially useful for the diagnosis of acute hepatitis E virus infection in field and emergency settings and in resource-poor countries.  相似文献   

2.
A new test for rapid detection of HIV antibodies (HIVCHEK) was evaluated. A total of 107 sera were examined. Of these, 60 were from healthy blood donors and the rest from a serum panel containing HIV positives and samples with false positive reactions in ELISA and unspecific bands in the western blot (WB). There was close agreement (100%) between the methods. The specificity of the HIVCHEK was 100% in this study. The sensitivity was acceptably high based on testing of consecutive serum samples from two seroconversion patients. The test was rapid and easy to perform, and no extra equipment was needed.  相似文献   

3.
BACKGROUND: Hantaviruses are associated with two human diseases: haemorrhagic fever with renal syndrome (HFRS) and Hantavirus pulmonary syndrome (HPS). Puumala virus (PUUV), which is one of the Hantaviruses, is a causative agent of nephropathia epidemica (NE), a mild form of HFRS. OBJECTIVE: a new 5 min rapid test, POC PUUMALA (Erilab Ltd, Finland), for detecting IgM antibodies to PUUV was evaluated and compared with the commercially available Hantavirus (Puumala) IgM ELISA test (Progen, Germany). Discrepant test results between the two tests were confirmed by a mu-capture reference EIA. STUDY DESIGN: Two hundred and thirty five serum samples, which had earlier been analyzed with the Progen IgM ELISA, were assayed with the POC PUUMALA rapid test. Five persons, without knowing the Progen IgM ELISA test results, interpreted independently the rapid test results. In addition, a panel of 48 serum samples was analyzed in parallel with the rapid test and the Progen IgM ELISA by one technician in daily routine diagnostics in a clinical microbiology laboratory. RESULTS: the agreement between the results of the five interpreters was 95%, and the congruence of the results between individual readers and commercial ELISA test varied from 93 to 96%. Diagnostic efficacy of the rapid test varied between 98 and 99% compared with 96% of the Progen IgM ELISA. The POC PUUMALA rapid test showed higher or similar sensitivity compared with the Progen IgM ELISA, whereas both the tests had similar levels of specificity. CONCLUSIONS: the analytical performance of the POC PUUMALA rapid test was found to be as good or even slightly better than the analytical performance of the Progen IgM ELISA. In addition, the rapid and straightforward procedure makes the POC PUUMALA a feasible tool for the diagnosis of the acute PUUV infection.  相似文献   

4.
The performance characteristics of a rapid immunochromatographic-screening test, SD Bioline HIV-1/2 3.0 (Standard Diagnostics Inc., Kyonggi-do, South Korea) on 23,754 sera and 30 plasma samples are reported. The sensitivity and specificity for the assay on serum samples are 100% and 99.4%, respectively. The assay detected antibodies in individuals infected with human immunodeficiency virus type 1 (HIV-1) genotypes A and C and HIV-2. This straightforward assay is a reliable diagnostic tool for screening HIV in resource-poor settings.  相似文献   

5.
Although human immunodeficiency virus (HIV) antigen assays are of limited value for monitoring antiretroviral therapy, they play an important role for confirmatory testing of fourth generation HIV screening enzyme immunoassay (EIA) reactive samples. In a multicenter study, a new automated rapid p24 antigen assay, Elecsys HIV Ag (Roche Diagnostics Boehringer Mannheim GmbH, Penzberg, Germany), was compared to FDA licensed tests (Abbott HIV-1 Ag monoclonal and Coulter HIV-1 p24 antigen assay). In the evaluation 27 seroconversion panels were included, sera from the acute phase of infection, single and follow-up samples from HIV antibody positive patients, dilution series of HIV antigen positive standards, sera and cell culture supernatants infected with different HIV-1 subtypes (A-H, and O) HIV-2 and recombinant HIV-1 (gag/env) isolates. To challenge the specificity of the new assay, 2565 unselected blood donors, sera from pregnant women, dialysis and hospitalized patients and 407 potentially cross-reactive samples were investigated. Acute HIV infection was detected in three to eight seroconversion panels earlier with Elecsys HIV Ag than with the alternative assays. Higher numbers of serum samples from HIV infected patients tested positive by Elecsys HIV Ag than with the comparative assays. All HIV-1 subtypes and HIV-2 isolates were recognized with Elecsys HIV Ag. Abbott HIV-1 Ag monoclonal and Coulter HIV-1 p24 antigen assay showed a variable sensitivity for the different HIV-1 subtypes. The specificity of Elecsys HIV Ag and Coulter HIV-1 p24 antigen assay were 99.8 and 99.93%, respectively. All the eight sera that were false reactive by Elecsys HIV Ag were tested negative with the Elecsys HIV Ag Neutralization Test. In conclusion, Elecsys HIV Ag was more sensitive than the alternative assays and showed a high specificity in combination with the neutralization assay. The very short incubation time of 18 min and the fully automated procedure of Elecsys HIV Ag which permits direct testing from the primary patient blood collection tube, represent a major improvement for routine laboratory diagnosis in comparison to the alternative assays.  相似文献   

6.
Barriers to effective diagnostic testing for human immunodeficiency virus type 1 (HIV-1) infection can be reduced with simple, reliable, and rapid detection methods. Our objective was to determine the accuracy, sensitivity, and specificity of a new rapid, lateral-flow immunochromatographic HIV-1 antibody detection device. Preclinical studies were performed using seroconversion, cross-reaction, and interference panels, archived clinical specimens, and fresh whole blood. In a multicenter, prospective clinical trial, a four-sample matrix of capillary (fingerstick) whole-blood specimens and venous whole blood, plasma, and serum was tested for HIV-1 antibodies with the Efoora HIV rapid test (Efoora Inc., Buffalo Grove, IL) and compared with an enzyme immunoassay (EIA) (Abbott Laboratories) licensed by the Food and Drug Administration. Western blot and nucleic acid test supplemental assays were employed to adjudicate discordant samples. Preclinical testing of seroconversion panels showed that antibodies were often detected earlier by the rapid test than by a reference EIA. No significant interference or cross-reactions were observed. Testing of 4,984 archived specimens yielded a sensitivity of 99.2% and a specificity of 99.7%. A prospective multicenter clinical study with 2,954 adult volunteers demonstrated sensitivity and specificity for the Efoora HIV rapid test of 99.8% (95% confidence interval [CI], 99.3 and 99.98%) and 99.0% (95% CI, 98.5 and 99.4%), respectively. Reactive rapid HIV-1 antibody detection was confirmed in 99.6% of those with a known HIV infection (n = 939), 5.2% of those in the high-risk group (n = 1,003), and 0.1% of those in the low-risk group (n = 1,012). For 21 (0.71%) patients, there was discordance between the results of the rapid test and the confirmatory EIA/Western blot tests. We conclude that the Efoora HIV rapid test is a simple, rapid assay for detection of HIV-1 antibodies, with high sensitivity and specificity compared to a standardized HIV-1 EIA.  相似文献   

7.
One hundred and twenty reactive sera were selected from specimens studied by enzyme immunoassay (EIA, Abbott Laboratories, Abbott Park, North Chicago, IL) for antibodies against human immunodeficiency virus (HIV-1). Using these sera, the 'WesPage' system (American Bionetics, Inc., Haywood, CA), was compared to the Western blot evaluation performed by a commercial reference laboratory (Abbott Laboratories, Abbott Park, North Chicago, IL). Using criteria established by the Food and Drug Administration, all major bands representing specific antigens of HIV-1 and their corresponding antibodies were identified on the immunoblot membrane when the strongly reactive control serum was used in the assay. The weakly reactive control serum demonstrated antibodies to the p24 core antigen and the gp120/160 envelope antigen of the virus in addition to others. The non-reactive control serum did not react with any antigen on the immunoblot sheet. All results obtained by our evaluation agreed with the reference laboratory results. The WesPage assay offers a combination of advantages which include rapid turn around time, less direct contact with potentially infectious materials, good resolution of bands and high reproducibility of results.  相似文献   

8.
The genes encoding the Erns and E2 antigen epitopes of classical swine fever virus (CSFV) were expressed as a chimeric protein in Escherichia coli BL21 by pET expression system. The antigenicity of the expressed protein CnC2 was identified by indirect enzyme-linked immunoabsorbant assay (ELISA) and immunoblot with anti-CSFV antibodies. Based on the CnC2 protein, an immunochromatographic strip was developed to evaluate the antibody titer of serum samples from swine vaccinated with CSFV vaccine rapidly. The chimeric protein used as a detector was labeled with colloidal gold. Staphylococcal protein A (SPA) and anti-CnC2 monoclonal antibodies (mAbs) were blotted onto the nitrocellulose membrane as the test and control lines, respectively. The strip assay could be performed within 5min, which did not require any special equipment or skills. Through testing sera against various strains of CSFV, the sensitivity of the strip was determined to be 97.0% (65/67) and the specificity was 100% (98/98). The strip results were consistent with those of the existing commercial ELISA kit, and their correlation coefficient was 0.935. In conclusion, the immunochromatographic strip was an acceptable method for surveying CSFV-antibody titers in pigs.  相似文献   

9.
10.
An immunochromatographic test (ICT) with recombinant surface antigen 1 of Neospora caninum (NcSAG1) was developed for the rapid detection of antibodies to N. caninum in cattle. The ICT was used to clearly discriminate between immunofluorescent-antibody test (IFAT)-positive bovine sera and IFAT-negative bovine sera. Serum samples collected from cattle in Yanbian, China, were examined by the ICT. Of the 96 serum samples, 23 (24.0%) were positive by the ICT, and 19 (19.8%) samples were positive by a previously developed enzyme-linked immunosorbent assay (ELISA). Eighteen of 19 ELISA-positive samples were positive according to the ICT. A good agreement was found between the results of the ICT and the ELISA. The results presented here suggest that the ICT with recombinant truncated NcSAG1 fused to glutathione S-transferase is a useful and reliable method for the detection of antibodies to N. caninum in cattle.  相似文献   

11.
This study was performed to determine the feasibility of using saliva as a diagnostic medium for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 under nonlaboratory conditions and to evaluate the performance characteristics of such a test. We developed for this purpose a self-contained kit (Saliva. Strip [ST]), which combines the collection and processing, as well as the analysis, of the specimen. The kit's performance was evaluated in a blinded study. Saliva collection was facilitated with a specially designed device that contains a sample adequacy indicator, and immunochromatography test strips were used for the analysis. A total of 1,336 matched serum and saliva specimens (684 reactive and 652 nonreactive specimens) were tested. We tested sera using an enzyme immunoassay (EIA) and a rapid strip test. Sera reactive in one of the assays were also analyzed by Western blotting. Sensitivity and specificity were 99.4 and 99.4%, respectively, for ST, 100 and 99.1%, respectively, for EIA, and 99.7 and 100%, respectively, for the serum strip test. The saliva test performed well when HIV-2-positive sera or a low-titer performance panel (HIV-1) of serum or plasma specimens were diluted (1:2,000) in nonreactive saliva. Because the methodology we present here uses a noninvasively obtained medium, the methodology may be suitable for use in the field where laboratory support and personnel are limited, such as community outreach programs, doctors' offices, surveillance studies, and community hospitals.  相似文献   

12.
The Genie HIV-1/HIV-2 rapid assay was compared with an enzyme-linked immunosorbent assay and Western blot (immunoblot) by using 540 serum specimens from four different populations. The Genie HIV-1/HIV-2 assay was easy to perform, required no equipment, provided visual results within 10 min, and demonstrated excellent sensitivity and specificity compared with the Western blot.  相似文献   

13.
A strip test was developed for detection of infectious myonecrosis virus (IMNV) using a pair of monoclonal antibodies (MAbs), called IMN7 and IMC6, that are specific for the N and C fragments, respectively, of the IMNV capsid protein. The test strips were placed in plastic cassettes and stored desiccated in sealed plastic bags. In detection assays using the test-strip cassettes, 100-μl samples of application buffer containing homogenates from muscles or pleopods of normal or IMNV-infected shrimp were applied to the cassette sample chamber. Subsequent flow through the glass-fiber pad and the nitrocellulose membrane strip led to the development of visible antibody-protein complexes within 15 min. In samples containing IMNV, viral capsid protein bound to gold-labeled IMN7 in the glass-fiber pad and the complex was subsequently captured by MAb IMC6 at the T line to form a reddish-purple band. Any unbound gold-labeled IMN7 migrated past the T line to be captured by the GAM antibody to form a band at the C line. Samples without IMNV or containing it below the test detection limit gave reddish-purple bands only at the C line. The sensitivity of the test was comparable to that of dot blot tests using single MAbs but was ~300-fold less sensitive than a one-step RT-PCR test for IMNV. Despite this lower sensitivity, the strip test has advantages of low cost, speed and simplicity (i.e., no sophisticated equipment or specialized skills required), and it is appropriate for use by farmers for pathogen confirmation when IMNV is suspected in diseased shrimp.  相似文献   

14.
An immunochromatographic test was developed for rapid diagnosis of bovine viral diarrhea virus (BVDV) infections using monoclonal antibodies against the nonstructural protein, NS3, of the virus. The kit detected specifically the NS3 of various BVDV strains. Using the kit, leukocyte extracts of cattle infected persistently with BVDV were found positive while those of healthy cattle were negative. The sensitivity and specificity of this kit in compared with virus isolation were 100% and 97.2%, respectively. Furthermore, the test also gave positive results for calves infected acutely with BVDV in experimental infection. The BVDV antigen was detected in 1 ml of blood using a relatively simple procedure. This test kit should be useful for rapid diagnosis of BVD.  相似文献   

15.
A newly introduced single strip line immunoassay was evaluated as a possible alternative to Western blot for the differential detection of antibodies to multiple HIV-1 and HIV-2 antigens in human serum. In a panel of 153 sera found to be positive twice in currently used screening tests, the line immunoassay and the Western blot detected 44 true positive results. Using Western blot as reference method, the line immunoassay gave 100 % specificity and sensitivity. These results suggest that the line immunoassay may be a viable alternative to Western blot.  相似文献   

16.
Rapid detection of human immunodeficiency virus (HIV) antibodies is of great importance in developing and developed countries to diagnose HIV infections quickly and at low cost. In this study, two new immunochromatographic rapid tests for the detection of HIV antibodies (Aware HIV-1/2 BSP and Aware HIV-1/2 U; Calypte Biomedical Corporation) were evaluated in rural Africa to determine the tests' performance and comparability to commercially available conventional enzyme immunoassay (EIA) and Western blot (WB) tests. This prospective study was conducted from March 2005 through May 2005 using serum and urine from respondents in the Rakai Community Cohort Survey. Nine hundred sixty-three serum samples were tested with the Aware blood rapid assay (Aware-BSP) and compared to two independent EIAs for HIV plus confirmatory Calypte WB for any positive EIAs. The sensitivity of Aware-BSP was 98.2%, and the specificity was 99.8%. Nine hundred forty-two urine samples were run using the Aware urine assay (Aware-U) and linked to blood sample results for analysis. The sensitivity of Aware-U was 88.7% and specificity was 99.9% compared to blood EIAs confirmed by WB analysis. These results support the adoption of the Aware-BSP rapid test as an alternative to EIA and WB assays for the diagnosis of HIV in resource-limited settings. However, the low sensitivity of the Aware-U assay with its potential for falsely negative HIV results makes the urine assay less satisfactory.  相似文献   

17.
A total of 215 serum samples were tested for antibodies against human immunodeficiency virus type 2 (HIV-2) with an immunofluorescence assay (IFA). Some samples originated from Denmark and some originated from Guinea-Bissau. The IFA results were compared with enzyme-linked immunosorbent assay (ELISA) and Western (immuno-) blot (WB) results. Twenty-nine serum samples were found to be true positive for HIV-2 antibodies as judged from WB and radioimmunoprecipitation results; all of these were also found to be positive in the HIV-2 IFA. Of 80 serum samples originating from HIV-1-infected persons, 60% showed reactivity in the HIV-2 ELISA, and 51% cross-reacted with at least one band in the HIV-2 WB. None of the sera cross-reacted in the HIV-2 IFA. A total of five serum samples (three African and two Danish) gave unspecific results in the HIV-2 IFA. It is concluded that the HIV-2 IFA is more specific and at least as sensitive as a first-generation ELISA and that IFA is superior to WB in discriminating between HIV-1 and HIV-2 infections.  相似文献   

18.
A new immunochromatographic rapid test, POC PUUMALA (Erilab Ltd., Kuopio, Finland), for detection of acute-phase Puumala virus (PUUV) infection was developed based on a highly purified baculovirus-expressed PUUV nucleocapsid protein antigen and lateral immunodiffusion techniques. After addition of sample (5 microl of serum, plasma, or fingertip blood) and buffer, PUUV-specific immunoglobulin M (IgM) antibodies, if present, together with the gold-conjugated anti-human IgM, formed a specific colored line in 5 min. The sensitivity and specificity of the test were evaluated with 200 serum samples and 30 fingertip blood samples. The reference method for the serum samples was a micro-capture enzyme immunoassay (EIA) for IgM and an immunofluorescence assay (IFA) for IgG antibodies. The analytical sensitivity and specificity of the rapid test were 100 and 99%, respectively, for unfrozen serum samples (n = 103; 12 PUUV IgM-positive samples). When freeze-thawed serum samples were used, the sensitivity and specificity were each 97.1% (n = 70; 35 PUUV IgM-positive samples). The specificity of the test was 96.2% for 27 serum samples with nonspecific IgM antibodies or rheumatoid factor (RF). The fingertip blood samples (n = 30) were negative, but they gave clear positive results when spiked with IgM-positive sera (n = 20). The results were in good agreement with the standard diagnostic methods. The rapid performance, the lack of need for refined laboratory equipment, and the high specificity with fresh serum and fingertip blood samples indicate that the developed POC PUUMALA rapid test is a useful tool for fast diagnosis of acute PUUV infection.  相似文献   

19.
The immunochromatographic test (ICT) for the rapid diagnosis of malaria has been marketed for several years. In a study in which three Centres of Tropical Medicine participated and data were pooled, performance of the test varied considerably when comparing the results between each centre. The sensitivity of ICT in 2,343 patients tested in our services was 100% and the specificity 99.74%. Moreover, two patients with a positive ICT would initially have been missed by expert microscopy, with Plasmodium falciparum malaria being confirmed microscopically some hours later. The principal reasons for the better performance of the test in our series appear to be blood collection in EDTA vials and considerable experience with handling and interpreting the ICT test.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号