1.
目的: 研究复合树脂与玻璃陶瓷的微拉伸粘接强度,以及树脂表面处理和老化对粘接强度的影响。方法: 制备离体牙牙本质块、树脂块及瓷试块,使用树脂水门汀粘固。根据粘固底物(牙本质与瓷或树脂与瓷)、不同树脂表面处理以及是否温度循环老化进行分组。对照组为牙本质与瓷粘固(A1、A2组);实验组为树脂与瓷粘固,对树脂表面不处理(B1、B2组)或分别进行以下处理,即甲基丙烯酸酯单体(C1、C2组)、硅烷化(D1、D2组)、粗化(E1、E2组)、抛光(F1、F2组)处理后再与瓷粘固。将粘固后的试块切为长方体试件,试件制备后即刻(A1~F1组)或经温度循环后(A2~F2组)测试微拉伸粘接强度。扫描电镜观察试件断面形态,采用单因素方差分析对所得数据进行统计学分析。结果: 老化前后,未经表面处理的树脂与瓷的微拉伸粘接强度[B1 (30.02±3.85) MPa,B2 (26.83±3.14) MPa]均高于牙本质与瓷[A1 (20.55±4.51) MPa,A2 (12.94±0.69) MPa](P<0.05)。与未行表面处理(B1、B2组)相比,经表面处理后树脂与瓷(C1~F1、C2~F2组)的粘接强度差异无统计学意义。结论: 树脂与瓷粘固,可获得不低于牙本质与瓷的粘接强度,对树脂进行甲基丙烯酸酯单体处理、硅烷化、粗化或抛光等表面处理不能有效提升树脂与瓷的粘接强度。  相似文献   

2.
目的:通过自黏性流动树脂与自酸蚀粘接剂以及传统型复合树脂的比较,研究了自黏性流动树脂的性能,并进一步明确酸蚀预处理对自黏性流动树脂与牙本质粘接性能以及自酸蚀粘接剂与牙本质粘接性能的影响。方法:对90颗牛牙进行牙体预备,暴露牙本质,随机平均分为3组(A组、B组、C组):A组为自黏性流动树脂与牙本质粘接、B组为自黏性流动树脂加自酸蚀粘接剂与牙本质粘接、C组为传统型复合树脂加自酸蚀粘接剂与牙本质粘接。根据是否行酸蚀预处理,进一步分为非酸蚀组(记为A1组、B1组、C1组)和酸蚀组(记为A2组、B2组、C2组)。测试粘接试样的剪切粘接强度,并对测试结果进行单因素方差(one-way ANOVA,LSD)分析。结果:A1组的粘接强度[(3.39±1.71)MPa]低于B1组的粘接强度[(21.58±4.50)MPa],且两组之间的差异有统计学意义(P<0.05);B1组的粘接强度和C1组的粘接强度[(19.31±6.79)MPa]之间的差异没有统计学意义(P>0.05)。酸蚀预处理后,A2组的粘接强度[(6.75±3.54)MPa]大于A1组,但酸蚀预处理导致自酸蚀粘接剂与牙本质的粘接强度降低,即B2组[(16.56±7.39)MPa]的粘接强度低于B1组,C2组[(11.31±5.54)MPa]的粘接强度低于C1组。结论:自黏性流动树脂与自酸蚀粘接剂一起使用时,与牙本质的粘接强度高于单独使用自黏性流动树脂。与自酸蚀粘接剂一起与牙本质粘接时,自黏性流动树脂与传统型复合树脂之间的差异没有统计学意义,但是,酸蚀预处理会降低自酸蚀粘接剂与牙本质的粘接强度,并使粘接强度结果的变异系数增大。  相似文献   

3.
比较3种暂时修复体材料(热凝树脂、聚合瓷和CAD/CAM树脂)与牙本质粘接的剪切粘接强度(SBS)的差异。制作直径4 mm,高4 mm的热凝树脂、聚合瓷、计算机辅助设计与制作(CAD/CAM)树脂试件各15个,采用Scotchbond通用型粘接剂和RelyXTMUltimate非自粘接树脂水门汀将试件恒定压力下粘接于45颗人离体牙颊侧或舌侧牙本质面上,然后于(37±2)℃蒸馏水中储存24 h后进行SBS测试,记录断裂峰值并进行比较。扫描电镜观察试件处理前、牙本质粘接断面及试件粘接断面的形态,使用体视显微镜观察试件粘接界面破坏形式。结果显示,热凝树脂、聚合瓷、CAD/CAM树脂的SBS分别为(4.84±0.95) MPa、(11.20±1.49) MPa、(5.93±1.81) MPa。3种暂时修复体材料的SBS比较差异有统计学意义(P <0.05);其中聚合瓷的SBS最大,热凝树脂的SBS最小。扫描电镜观察结果显示,热凝树脂和CAD/CAM树脂粘接前表面均较光滑;而聚合瓷粘接前表面有一定粗糙度。体视显微镜观察结果显示聚合瓷组粘接界面断裂方式表现为内聚破坏和混合破坏,而热凝树脂组和...  相似文献   

4.
目的探讨自粘结树脂水门汀对不同表面处理的人牙本质的粘结效果。方法将24个人牙本质试件随机分为3组,分别施以不同表面的处理(A组不处理;B组磷酸酸蚀10s;C组磷酸酸蚀10s+One-step粘结剂)。使用Biscem双固化树脂水门汀制作牙本质/树脂水门汀粘结试件,测试剪切粘结强度,扫描电镜观察粘结界面形态。结果 A组试件的粘结强度值为6.13±1.11MPa,B组为6.53±1.12MPa,C组为9.46±0.52MPa。C组的粘结强度值最高,A组和B组的粘结强度值无统计学差别。结论是否用磷酸酸蚀牙本质对Biscem自粘结树脂水门汀的粘结强度没有影响,但磷酸酸蚀结合应用One-step粘结剂进行牙本质表面处理能够提高Biscem树脂水门汀的粘结强度。  相似文献   

5.
目的:研究3种不同的牙本质表面钻针处理方式对自酸蚀牙本质粘接耐久性的影响。方法:选择2021年3月-2022年3月航天中心医院已拔除的第三磨牙30颗,制得牙本质试件。将试件随机分为三组,分别使用牙体预备用金刚砂钻针、磨光用金刚砂钻针和牙体预备用钨钢钻针进行牙本质表面预备,并使用自酸蚀树脂粘接水门汀进行粘接,测量牙本质表面老化粘接强度,观察断裂模式。结果:钨钢组牙本质粘接强度(8.18±1.31)MPa高于两金刚砂钻针组,差异有统计学意义(P<0.05)。结论:与金刚砂钻针相比,钨钢钻针预备的牙本质表面与自酸蚀树脂粘接水门汀的粘接耐久性更强。  相似文献   

6.
目的:研究不同温度条件下新型大气压冷等离子体(radio-frequency atmospheric-pressure glow discharge,RF-APGD)处理对牙本质粘接强度的影响。方法:(1)收集新鲜拔除的、无龋坏的、完整的第三磨牙52颗,采用精密低速切割机制备平行于牙合中层牙本质薄片,每颗离体牙制备1片 [(900±100) μm]。将52个中层牙本质薄片随机分为对照组和实验组,其中对照组4片,无处理;实验组48片,按新型RF-APGD等离子体不同处理温度(4 ℃、10 ℃、20 ℃、30 ℃)平均分为4组,每大组12片。每大组按照不同处理时间(10 s,20 s,30 s)平均分为3个小组,每小组4片。采用扫描电镜观察脱矿牙本质表面形貌。(2)收集20颗完整第三磨牙随机分为对照组和4个实验组,每组4颗。对照组,无处理;4 ℃、10 ℃、20 ℃和 30 ℃ 4个实验组,每组采用新型RF-APGD等离子体处理20 s。实验组及对照组采用低速水冷精密切割机垂直于牙长轴去除牙合面牙釉质,暴露中层牙本质;采用32%磷酸酸蚀剂对牙本质表面进行酸蚀;采用牙本质粘接剂和树脂进行牙本质-树脂粘接,采用万能力学机进行牙本质-树脂粘接试件即刻微拉伸强度测定,观察不同温度新型RF-APGD等离子体处理对牙本质-树脂即刻粘接性能的影响。结果:(1)扫描电镜观察脱矿牙本质表面形貌显示,30 ℃和20 ℃新型 RF-APGD 等离子体处理组,脱矿牙本质胶原纤维表面经新型RF-APGD等离子体处理10 s即会出现微结构的破坏;10 ℃新型RF-APGD等离子体处理脱矿牙本质表面 20 s,即会出现牙本质胶原纤维之间间隙变小、表面结构坍塌等现象;4 ℃新型RF-APGD等离子体处理10 s、20 s及30 s,脱矿牙本质表面胶原纤维网状结构均能维持蓬松结构。(2)牙本质-树脂即刻微拉伸强度结果显示,对照组为(47.4±0.5) MPa,4 ℃、10 ℃、20 ℃和30 ℃新型RF-APGD等离子体处理组分别为(57.8±0.7) MPa、(51.9±0.7) MPa、(29.7±1.0) MPa和(22.2±1.5) MPa,其中4 ℃新型RF-APGD等离子体处理组所获得的微拉伸强度最高,与其他各组相比,差异具有统计学意义(P<0.05), 4 ℃和10 ℃新型RF-APGD等离子体处理组和对照组相比,牙本质-树脂微拉伸粘接强度分别提高了21.9%和9.5%。结论:4 ℃新型RF-APGD等离子体对脱矿牙本质胶原纤维的处理,较更高温度的新型RF-APGD等离子体更有利于提高牙本质-树脂的即刻粘接性能。  相似文献   

7.
目的:通过自黏性流动树脂与自酸蚀粘接剂以及传统型复合树脂的比较,研究了自黏性流动树脂的性能,并进一步明确酸蚀预处理对自黏性流动树脂与牙本质粘接性能以及自酸蚀粘接剂与牙本质粘接性能的影响。方法:对90颗牛牙进行牙体预备,暴露牙本质,随机平均分为3组(A组、B组、C组):A组为自黏性流动树脂与牙本质粘接、B组为自黏性流动树脂加自酸蚀粘接剂与牙本质粘接、C组为传统型复合树脂加自酸蚀粘接剂与牙本质粘接。根据是否行酸蚀预处理,进一步分为非酸蚀组(记为A1组、B1组、C1组)和酸蚀组(记为A2组、B2组、C2组)。测试粘接试样的剪切粘接强度,并对测试结果进行单因素方差(one way ANOVA,LSD)分析。结果:A1组的粘接强度[(3.39±1.71) MPa]低于B1组的粘接强度[(21.58±4.50) MPa],且两组之间的差异有统计学意义(P<0.05);B1组的粘接强度和C1组的粘接强度[(19.31±6.79) MPa]之间的差异没有统计学意义(P>0.05)。酸蚀预处理后, A2组的粘接强度[(6.75±3.54) MPa]大于A1组,但酸蚀预处理导致自酸蚀粘接剂与牙本质的粘接强度降低,即B2组[(16.56±7.39) MPa]的粘接强度低于B1组,C2组[(11.31±5.54) MPa]的粘接强度低于C1组。结论:自黏性流动树脂与自酸蚀粘接剂一起使用时,与牙本质的粘接强度高于单独使用自黏性流动树脂。与自酸蚀粘接剂一起与牙本质粘接时,自黏性流动树脂与传统型复合树脂之间的差异没有统计学意义,但是,酸蚀预处理会降低自酸蚀粘接剂与牙本质的粘接强度,并使粘接强度结果的变异系数增大。  相似文献   

8.
李冬梅  马楚凡  李晓军  郭天文 《医学争鸣》2008,29(11):1012-1014
目的:研究使用聚合后加压热处理的方法提高纯钛与两种瓷聚合体粘结强度的可行性,并观察对粘结界面老化性能的影响.方法:制作纯钛铸件64个,SiC水砂纸打磨,60#氧化铝喷砂,40 mL/LHF酸蚀处理表面后分为2组,制做钛-Solidex聚合瓷(Ti-Solidex)组和钛-Artglass聚合瓷(Ti-Artglass)组粘结试件,各组中随机取出一半试件进行聚合后加压热处理,比较处理前后试件剪切粘结强度和表面显微硬度的差异. 并通过冷热循环实验进行模拟老化处理,观察各组剪切粘结强度的变化.结果:聚合后加压热处理使Ti-Artglass组试件的剪切粘结强度由(25.69±1.67) MPa增加到(28.12±1.24) MPa, Ti-Solidex组试件的剪切粘结强度由(18.94±1.98) MPa增加到(23.02±1.94) MPa,均有统计学差异(P<0.05). 同时,聚合后加压热处理也显著提高了树脂的表面显微硬度(P<0.05). 但水老化处理后各组试件的剪切粘结强度均显著降低(P<0.05).结论:聚合后加压热处理可以显著提高钛-瓷聚合体的剪切粘结强度和树脂的表面显微硬度,但对其耐老化性能没有明显改善.  相似文献   

9.
目的 比较全酸蚀树脂水门汀NX3、自酸蚀树脂水门汀Panavia F、新型自粘接树脂水门汀RelyX U200对牙釉质/牙本质与Vita MarkⅡ瓷块的剪切强度的影响.方法 预备60个Vita MarkⅡ瓷块,随机分为6组;预备30个牙釉质试件和30个牙本质试件,各随机分为3组.分别按NX3、Pan-avia F、RelyX U200使用说明将瓷块与牙釉质试件和牙本质试件进行粘接.37℃恒温水浴24 h后进行剪切强度测试,并观察断裂界面.结果 NX3、Panavia F的断裂界面以混合断裂为主,RelyX U200以界面断裂为主.NX3、Panavia F对牙釉质/牙本质与瓷块强度差异均无统计学意义,但明显高于RelyX U200(P<0.05).结论 自粘接树脂水门汀操作简便,但粘接强度较低.建议使用全酸蚀树脂水门汀和自酸蚀树脂水门汀对全瓷修复体进行粘接.  相似文献   

10.
目的:探讨自行研制的铸瓷固位钉对牙本质-复合树脂界面粘结强度的影响,为铸瓷固位钉进一步的临床应用提供实验依据?方法:将40颗离体牙随机分为4组:A组,铸瓷固位钉组;B组,金属自攻螺纹钉组;C组,复合树脂钉组;D组,树脂直接充填组?采用IPS e. max Press热压铸瓷系统制作铸瓷牙本质固位钉,制备标准化牙本质-固位钉-复合树脂块试件,微拉伸实验测试各组试件粘结强度,体视显微镜下观察试件断裂面形态?结果:A?B两组试件粘结强度显著高于C?D两组,差异有统计学意义(P < 0.05);A组与B组?C组与D组组间粘结强度差异无统计学意义(P > 0.05)?A?C?D三组试件断裂模式以牙本质-树脂界面断裂为主,B组以牙本质内聚断裂为主?结论:作为一种新型牙本质固位钉,IPS e.max Press铸瓷固位钉可显著提升牙本质-复合树脂界面的粘结强度?  相似文献   

11.
目的比较使用3种不同牙本质黏结剂时,2种复合树脂核材料与精细粒度车针预备的牙本质之间的微拉伸黏结强度。方法本实验使用的2种复合树脂核材料为Bisfil-core和Luxacore,3种黏结剂为ONE-STEPRPLUS、Contax和ibond,各对应的组别为BO组、LO组、BC组、LC组、Bi组和Li组。18颗人类磨牙用于本实验,每组3颗牙齿。所有牙齿均去除冠部釉质,暴露出完整的表浅牙本质,并用精细粒度金钢砂车针预备牙本质。然后按照各厂家的说明完成黏结剂的应用并用2种核材料分别修复牙冠。牙齿在37℃的自来水中保存24 h后,沿与黏结面垂直的方向片切成厚约0.7 mm的薄片,然后修整黏结面,使其面积大约在1.0 mm2。样本在MTS Synergie100材料测试机上进行黏结强度测试,所得数据用方差分析和LSD检验进行统计学处理。结果各组的黏结强度分别为BO组(27.34±6.52)MPa、LO组(36.49±11.74)MPa、BC组(23.78±9.03)MPa、LC组(34.35±13.35)MPa、Bi组(29.12±7.99)MPa、Li组(32.63±8.17)MPa。统计学分析显示,黏结强度的差异在不同黏结剂之间无统计学意义,在不同的核材料之间差异有统计学意义。结论 3种黏结剂均可以满足临床需要,流动性复合树脂核材料可以显著提高黏结强度。  相似文献   

12.
Background The wet-bonding technique is recommended for the one-bottle dentin adhesive systems, but the moisture concept varies widely among the instructions of manufacturers as well as among investigators. The aim of this study was to evaluate the effects of different dentin surface moisture on the microtensile bond strength (s) of an ethanol/water-based adhesive system and an acetone-based system to dentin. Methods Forty intact human premolars extracted for orthodontic reasons were used. Superficial occlusal flat dentin surfaces of these premolars were exposed, finished with wet 600-grit silicon carbide paper. Under four wet and dry conditions (overwet, blot dry, one-second dry and desiccated), resin composite was bonded to dentin by using Single Bond (SB) or Prime & Bond NT (PB) according to the manufacturers' instructions. The teeth were longitudinally sectioned in the “x” and “y” directions to obtain bonded beams with a cross-sectional area of 0. 81 mm^2 with a slow-speed diamond saw. The bonded specimens were tested in tension at a crosshead speed of 1 mm/min until failure of the bonds. Failure modes were observed with a scanning electron microscope. The mean bond strengths were analyzed by one-way ANOVA and Turkey's test. Results The bond strength of the overwet/SB, blot dry/SB, one-second dry/SB and desiccated/SB groups was 10.87 MPa, 22.47 MPa, 24.91 MPa and 12. 99 MPa, respectively. The bond strength of the overwet/PB, blot dry/PB, one-second dry/PB and desiccated/PB groups was 10.02 MPa, 20. 67 MPa, 21.82 MPa and 10. 09 MPa, respectively. For both SB and PB, the blot dry group and one-second dry group revealed significantly higher bond strengths than the overwet and desiccated groups (P 〈0.05). Conclusions In order to achieve the highest bond strength to dentin, keeping appropriately moist condition is critical for the one-bottle dentin adhesive systems with solvent. the dentin surface in an ethanol/water or acetone  相似文献   

13.
目的:研究根管治疗过程中残留在牙本质表面的环氧树脂类根管封闭剂对牙本质-复合树脂粘接强度的影响,对比不同有机溶剂对其清除的效果。方法:选取新鲜无龋人第三磨牙离体牙25颗,切除冠部釉质,制备牙本质平面试件。试件随机分为5组,每组5颗离体牙。阴性对照组牙本质表面不做处理,不涂根管封闭剂,其他4个实验组试件牙本质表面涂布环氧树脂根管封闭剂AH Plus 5 min后,采用不同的清除措施:阳性对照组使用干棉球擦拭;乙酸戊酯、丙酮及乙醇有机溶剂实验组,分别用蘸有99%(体积分数)乙酸戊酯、99.5%(体积分数)丙酮及95%(体积分数)乙醇的棉球擦拭牙本质表面,直至体视显微镜(×10)下观察无残留 AH-Plus,去离子水冲洗3 s。制备1.0 mm × 1.0 mm 条状粘接树脂试样(n=45)用于测定微拉伸强度,体视镜下观察断裂类型。制备1.0 mm厚片状试样(n=4)用于扫描电镜下观察粘接界面。采用单因素方差分析比较不同实验组的微拉伸粘接强度,应用卡方检验比较不同组之间断裂类型的差异。结果:五组间粘接强度差异有统计学意义(P<0.001)。干棉球组[(38.69±8.60)MPa ]、乙醇组[(37.14±12.01)MPa ]与阴性对照组[(43.86±7.99)MPa ]相比,粘接强度明显降低(P<0.05)。干棉球组与乙醇组粘接强度差异无统计学意义(P=0.426)。丙酮组、乙酸戊酯组、阴性对照组三者粘接强度差异无统计学意义(P>0.05),丙酮、乙酸戊酯清洁牙本质表面后粘接强度分别达到 (45.94±10.37) MPa、(43.99±7.01) MPa。乙醇组粘接强度明显低于丙酮组和乙酸戊酯组(P<0.05)。扫描电镜下观察可见:干棉球组及乙醇组树脂突短小而稀疏,且在乙醇组的粘接界面可以看到残留的根管封闭剂;阴性对照组、乙酸戊酯组及丙酮组树脂突均匀致密。不同组之间断裂类型分布差异没有统计学意义(P=0.086)。结论:环氧树脂类根管封闭剂残留使牙本质树脂粘接强度下降。丙酮与乙酸戊酯对牙本质表面残留的AH Plus的清除效果较好,优于乙醇及干棉球。  相似文献   

14.
目的:研究生物活性玻璃(bioactive glass, BG)预处理对维持牙本质粘接界面耐久性的作用。方法:选取30颗无龋坏第三磨牙,去除冠部釉质制备牙本质平面,随机均分对照组、BG组、三偏磷酸钠(sodium trimetaphosphate, STMP)-聚丙烯酸(polyacrylic acid, PAA)-BG组(S-P-BG组)。各组均使用35%(质量分数)磷酸酸蚀牙本质样本,BG组再使用0.5 g/L BG涂擦酸蚀后的牙本质样本;S-P-BG组先使用5%(质量分数)STMP、5%(质量分数)PAA浸泡酸蚀后的牙本质样本1 min,再使用0.5 g/L BG涂擦牙本质样本。各组样本使用3M Single Bond 2粘接剂及3M Z350XT复合树脂粘接,并制备微拉伸柱状样本,每颗牙的柱状样本按时间随机分为24 h、1个月、3个月组。各组样本保存在37 ℃人工唾液(artificial saliva, AS)中相应时间后,进行微拉伸粘接强度测试,并使用单因素方差分析及LSD法进行统计学分析,扫描电镜下观察粘接断裂界面形貌。另选取27颗无龋坏第三磨牙制备牙本质平面,随机分为对照组、BG组、S-P-BG组,并按上述分组处理牙本质样本,再使用含0.1%(质量分数)罗丹明B的3M Single Bond 2粘接剂完成粘接。去除样本牙根暴露髓腔,并保存在 37 ℃ AS中24 h、1个月、3个月后,髓腔内放置0.1(质量分数)荧光素钠溶液染色1 h,激光共聚焦显微镜观察粘接界面形态及混合层微渗漏。结果:AS中浸泡24 h、1个月后,3组微拉伸粘接强度间的差异无统计学意义(P>0.05);浸泡3个月后,S-P-BG组微拉伸粘接强度为(36.91±7.07) MPa,高于对照组粘接强度(32.73±8.06) MPa,且差异有统计学意义(P=0.026);对照组、BG组3个月的微拉伸粘接强度较24 h呈下降趋势,且差异有统计学意义(对照组P=0.017,BG组P=0.01);S-P-BG组3个月微拉伸粘接强度较24 h粘接强度[(37.99±7.98) MPa]下降,但差异无统计学意义(P>0.05)。扫描电镜观察24 h粘接断裂面,3组均未见明显矿化;1个月、3个月后,BG组、S-P-BG组的粘接界面可见矿物质形成,S-P-BG组无明显胶原暴露。激光共聚焦显微镜观察对照组、BG组与S-P-BG组树脂突形成的形态及数量无明显差异;3组样本粘接24 h后粘接界面混合层均有渗漏,3个月后对照组微渗漏增加,BG组和S-P-BG组混合层微渗漏减少。结论:BG预处理牙本质粘接界面能够在粘接界面形成矿物质,减少粘接混合层微渗漏;STMP、PAA 与BG共同预处理牙本质粘接界面,可能在一定程度上维持牙本质粘接修复的耐久性。  相似文献   

15.
目的:研究生物活性玻璃(bioactive glass, BG)预处理对维持牙本质粘接界面耐久性的作用。方法:选取30颗无龋坏第三磨牙,去除冠部釉质制备牙本质平面,随机均分对照组、BG组、三偏磷酸钠(sodium trimetaphosphate, STMP)-聚丙烯酸(polyacrylic acid, PAA)-BG组(S-P-BG组)。各组均使用35%(质量分数)磷酸酸蚀牙本质样本,BG组再使用0.5 g/L BG涂擦酸蚀后的牙本质样本;S-P-BG组先使用5%(质量分数)STMP、5%(质量分数)PAA浸泡酸蚀后的牙本质样本1 min,再使用0.5 g/L BG涂擦牙本质样本。各组样本使用3M Single Bond 2粘接剂及3M Z350XT复合树脂粘接,并制备微拉伸柱状样本,每颗牙的柱状样本按时间随机分为24 h、1个月、3个月组。各组样本保存在37 ℃人工唾液(artificial saliva, AS)中相应时间后,进行微拉伸粘接强度测试,并使用单因素方差分析及LSD法进行统计学分析,扫描电镜下观察粘接断裂界面形貌。另选取27颗无龋坏第三磨牙制备牙本质平面,随机分为对照组、BG组、S-P-BG组,并按上述分组处理牙本质样本,再使用含0.1%(质量分数)罗丹明B的3M Single Bond 2粘接剂完成粘接。去除样本牙根暴露髓腔,并保存在 37 ℃ AS中24 h、1个月、3个月后,髓腔内放置0.1(质量分数)荧光素钠溶液染色1 h,激光共聚焦显微镜观察粘接界面形态及混合层微渗漏。结果:AS中浸泡24 h、1个月后,3组微拉伸粘接强度间的差异无统计学意义(P>0.05);浸泡3个月后,S-P-BG组微拉伸粘接强度为(36.91±7.07) MPa,高于对照组粘接强度(32.73±8.06) MPa,且差异有统计学意义(P=0.026);对照组、BG组3个月的微拉伸粘接强度较24 h呈下降趋势,且差异有统计学意义(对照组P=0.017,BG组P=0.01);S-P-BG组3个月微拉伸粘接强度较24 h粘接强度[(37.99±7.98) MPa]下降,但差异无统计学意义(P>0.05)。扫描电镜观察24 h粘接断裂面,3组均未见明显矿化;1个月、3个月后,BG组、S-P-BG组的粘接界面可见矿物质形成,S-P-BG组无明显胶原暴露。激光共聚焦显微镜观察对照组、BG组与S-P-BG组树脂突形成的形态及数量无明显差异;3组样本粘接24 h后粘接界面混合层均有渗漏,3个月后对照组微渗漏增加,BG组和S-P-BG组混合层微渗漏减少。结论:BG预处理牙本质粘接界面能够在粘接界面形成矿物质,减少粘接混合层微渗漏;STMP、PAA 与BG共同预处理牙本质粘接界面,可能在一定程度上维持牙本质粘接修复的耐久性。  相似文献   

16.
目的:研究喷砂和微弧氧化两种金属表面处理方式及树脂粘结剂对钛合金与硬质复合树脂粘结强度和耐久性的影响。方法:应用CAD/CAM技术切削出80个底面直径10 mm、高8 mm的圆柱形钛合金试件。根据表面处理方式分为两组:喷砂组(sandblasting,SB)试件表面进行Al2O3 颗粒喷砂,微弧氧化组(microarc-oxidation,MAO)试件表面处理后形成疏松多孔的陶瓷膜结构。每组内根据是否应用树脂粘结剂分为SB-resin luting-N组(不使用)、SB-resin luting-Y组(使用)、MAO-resin luting-N组(不使用)、MAO-resin luting-Y组(使用)4个亚组。试件与Cemerage硬质复合树脂粘结固化,每组的各一半测试冷热循环0次和5 000次后的粘结强度,对比分析测试结果。扫描电镜观察粘结强度试验前后钛合金试件表面形貌。结果:喷砂联合树脂粘结剂组冷热循环0次后,钛合金与硬质复合树脂的粘结强度最高(16.2±1.8) MPa;微弧氧化未联合树脂粘结剂组冷热循环5 000次后,两者的粘结强度最低(8.9±1.5) MPa,喷砂和微弧氧化未联合树脂粘结剂组冷热循环5 000次后粘结强度分别为(10.7±2.2) MPa和(8.9±1.5) MPa,相比循环0次组降低,差异有统计学意义(P=0.000和P=0.001);喷砂和微弧氧化处理联合树脂粘结剂5 000次冷热循环后粘结强度分别为(15.5±2.1) MPa和(11.7±1.3) MPa,相比循环0次组降低,但差异无统计学意义(P=0.087和P=0.234)。结论:喷砂和微弧氧化两种表面处理方式联合树脂粘结剂均可提高钛合金与硬质复合树脂的粘结强度和耐久性,以喷砂组提高更为显著;目前受微弧氧化技术参数的限制,喷砂效果优于微弧氧化。  相似文献   

17.
目的:对比玻璃纤维桩表面经聚多巴胺或硅烷偶联剂处理后与树脂水门汀的微推出粘接强度,探讨玻璃纤维桩表面聚多巴胺化学改性处理对其与树脂水门汀粘接强度的影响. 方法:将30支玻璃纤维桩随机分成3组,每组10支,组1为聚多巴胺组,组2为硅烷化组,组3为对照组. 将各组纤维桩与树脂水门汀在根管内进行粘接,用精密切片机切出微推出实验试件,测定其微推出粘接强度并观察破坏模式. 结果:组1(聚多巴胺组)微推出粘接强度为(7. 909 ± 1. 987) MPa,组2(硅烷化组)为(5. 906 ± 0. 620) MPa,组3(对照组)为(4. 678 ± 0. 910) MPa,聚多巴胺组粘接强度值高于硅烷化组,差异有统计学意义(P<0. 05). 结论:相较硅烷化处理,应用聚多巴胺处理玻璃纤维桩表面可以更有效地提高其与树脂水门汀在根管内的微推出粘接强度.  相似文献   

18.
目的:探讨碳化二亚胺盐酸盐[1-ethyl-3-(3-dimethylaminopropyl) carbodiimide,EDC]乙醇溶液表面处理对牙本质即刻微拉伸粘接强度、断裂模式和粘接界面微观形态的影响。方法:称取不同质量EDC溶解于无水乙醇中,配制不同浓度(2、1、0.3、0.1、0.01 mol/L)的EDC乙醇溶液。将28颗人离体第三磨牙随机平分为7组:5种浓度的EDC处理组、未处理组、乙醇溶剂处理组。在低速精密切割机下去除牙合面牙釉质,暴露中层牙本质,35%(质量分数)磷酸凝胶酸蚀后根据不同分组对脱矿牙本质表面分别进行处理60 s,使用全酸蚀粘接剂(Single Bond 2)粘接处理后,堆塑复合树脂并固化。室温下保存24 h后,制备标准条形试件并测定微拉伸粘接强度,在体视显微镜下对试件的断裂模式进行观察。结果:2 mol/L组[(22.17±13.31) MPa]和1 mol/L组[(45.31±17.80) MPa]的粘接强度显著下降(P<0.05),粘接断裂模式发生的比例明显提高,分别为81.2%和41.3%。其余各组粘接强度差异无统计学意义(P>0.05)。结论:0.3、0.1和0.01 mol/L的EDC乙醇溶液表面处理对牙本质即刻粘接强度无明显影响,2 mol/L和1 mol/L的EDC乙醇溶液表面处理会显著降低牙本质即刻粘接强度。  相似文献   