1.

Purpose

Bone metastasis is an important factor for the treatment and prognosis of breast cancer patients. Whole-body bone scintigraphy (WBBS) can evaluate skeletal metastases, and 18F-FDG PET/CT seems to exhibit high specificity and accuracy in detecting bone metastases. However, there is a limitation of 18F-FDG PET in assessing sclerotic bone metastases because some lesions may be undetectable. Recent studies showed that 18F-fluoride PET/CT is more sensitive than WBBS in detecting bone metastases. This study aims to evaluate the usefulness of 18F-fluoride PET/CT by comparing it with WBBS and 18F-FDG PET/CT in breast cancer patients with osteosclerotic skeletal metastases.

Materials and Methods

Nine breast cancer patients with suspected bone metastases (9 females; mean age ± SD, 55.6 ± 10.0 years) underwent 99mTc-MDP WBBS, 18F-FDG PET/CT and 18F-fluoride PET/CT. Lesion-based analysis of five regions of the skeletons (skull, vertebral column, thoracic cage, pelvic bones and long bones of extremities) and patient-based analysis were performed.

Results

18F-fluoride PET/CT, 18F-FDG PET/CT and WBBS detected 49, 20 and 25 true metastases, respectively. Sensitivity, specificity, positive predictive value and negative predictive value of 18F-fluoride PET/CT were 94.2 %, 46.3 %, 57.7 % and 91.2 %, respectively. Most true metastatic lesions on 18F-fluoride PET/CT had osteosclerotic change (45/49, 91.8 %), and only four lesions showed osteolytic change. Most lesions on 18F-FDG PET/CT also demonstrated osteosclerotic change (17/20, 85.0 %) with three osteolytic lesions. All true metastatic lesions detected on WBBS and 18F-FDG PET/CT were identified on 18F-fluoride PET/CT.

Conclusion

18F-fluoride PET/CT is superior to WBBS or 18F-FDG PET/CT in detecting osteosclerotic metastatic lesions. 18F-fluoride PET/CT might be useful in evaluating osteosclerotic metastases in breast cancer patients.  相似文献   

2.

Objective

The aim of this study was to compare the diagnostic ability of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) with that of 99mTc-methylene diphosphonate (99mTc-MDP) bone scan for bone metastasis in staging patients with small cell lung cancer (SCLC).

Methods

Ninety-five patients with SCLC who underwent both 18F-FDG PET/CT and 99mTc-MDP bone scan for initial staging work-up were retrospectively enrolled. All 18F-FDG PET/CT and bone scan images were visually assessed. Bone metastasis was confirmed by histopathological results and all available clinical information.

Results

Of 95 patients with SCLC, metastatic bone lesions were found in 30 patients, and 84 metastatic lesions were evaluated on a lesion-basis analysis. The sensitivity of 18F-FDG PET/CT was 100?% on a per-patient basis and 87?% on a per-lesion basis, and there was no false-positive lesion on PET/CT images. In contrast, the sensitivity of the bone scan was 37?% on a per-patient basis and 29?% on a per-lesion basis. The bone scan showed 11 false-positive lesions. The bone scan detected two metastatic lesions that were not detected by PET/CT, which were outside the region scanned by PET/CT. On follow-up bone scan, 21 lesions that were not detected by the initial bone scan but were detected by PET/CT were newly detected.

Conclusions

In patients with SCLC, 18F-FDG PET/CT showed higher detection rate of bone metastasis than 99mTc-MDP bone scan. Thus, 18F-FDG PET/CT can replace bone scan in staging patients with SCLC.  相似文献   

3.

Purpose

l-[3-18F]-α–Methyltyrosine (18F-FAMT) was developed as an amino acid tracer for PET imaging to provide better specificity than 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) PET for cancer diagnosis. We investigated the diagnostic usefulness of 18F-FAMT in oral squamous cell carcinoma (OSCC). The correlation between tumour uptake of 18F-FAMT and L-type amino acid transporter 1 (LAT1) expression was determined.

Methods

The study group comprised 68 OSCC patients who underwent both 18F-FAMT and 18F-FDG PET. Resected tumour sections were stained by immunohistochemistry for LAT1, CD98 and Ki-67, and microvessel density was determined in terms of CD34 and p53 expression.

Results

The sensitivity of primary tumour detection by 18F-FAMT and 18F-FDG PET was 98 % and 100 %, respectively. The sensitivity, specificity and accuracy of 18F-FAMT PET for detecting malignant lymph nodes were 68 %, 99 % and 97 %, respectively, and equivalent values for 18F-FDG PET were 84 %, 94 % and 94 %, respectively. The specificity and accuracy of 18F-FAMT were significantly higher than those of 18F-FDG. The uptake of 18F-FAMT was significantly correlated with LAT1 expression, cell proliferation and advanced stage. The expression of LAT1 in OSCC cells was closely correlated with CD98 levels, cell proliferation and angiogenesis.

Conclusion

18F-FAMT PET showed higher specificity for detecting malignant lesions than 18F-FDG PET. The uptake of 18F-FAMT by OSCC cells can be determined by the presence of LAT1 expression and tumour cell proliferation.  相似文献   

4.

Objective

l-[3-18F]-alpha-methyltyrosine (18F-FAMT) is an amino-acid tracer for positron emission tomography (PET), with uptake related to overexpression of L-type amino-acid transporter 1 and proliferative activity in tumour cells. This study evaluated the diagnostic performance of 18F-FAMT PET compared with 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) PET in patients with multiple myeloma (MM).

Methods

Eleven patients with MM (newly diagnosed, n?=?3; relapsed after treatment, n?=?8) underwent whole-body 18F-FAMT and 18F-FDG PET within a 2-week interval. Magnetic resonance imaging (MRI) of the spine was also performed to assess patterns of bone marrow infiltration. Tracer uptake was semi-quantitatively evaluated using maximal standardized uptake value (SUVmax). Mean SUV was also determined for normal bone marrow and the aortic arch as mediastinal background SUV to calculate lesion-to-bone marrow (L/B) and lesion-to-mediastinum (L/M) ratios, respectively. Those values were statistically compared using Student??s t test.

Results

In 8 patients showing focal infiltration on MRI, 34 FDG-avid bone lesions were identified, with each showing increased FAMT uptake. Mean SUVmax and L/B ratio of FDG (3.1?±?1.2 and 3.3?±?1.9, respectively) were significantly higher than those of FAMT (2.0?±?1.0 and 2.6?±?1.1, respectively; p?<?0.05 each). In contrast, the L/M ratio of FDG showed no significant difference to that of FAMT (2.2?±?1.0 and 2.4?±?1.2, respectively; p?=?0.3).

Conclusions

Clear 18F-FAMT PET uptake was seen in most 18F-FDG-avid lesions among patients with MM, and an equivalent semi-quantitative value was obtained using L/M ratio. Our preliminary data suggest that 18F-FAMT PET provides a useful imaging modality for detecting active myelomatous lesions.  相似文献   

5.

Objective

L-3-[18F]-fluoro-α-methyl tyrosine (18F-FAMT) is an amino acid tracer for positron emission tomography/computed tomography (PET/CT) which specifically transported into cancer cells by L-type amino acid transporter 1 (LAT1). LAT1 overexpression in tumors is significantly correlated with cell proliferation and angiogenesis. 18F-FAMT PET/CT, fluorine-18-fluorodeoxyglucose (18F-FDG) PET/CT and magnetic resonance imaging (MRI) were compared for their diagnostic performance in the detection of bone marrow invasion in patients with oral squamous cell carcinoma (OSCC).

Methods

Twenty-seven patients with OSCC on the upper or lower alveolar ridge underwent staging by MRI, 18F-FDG PET/CT and 18F-FAMT PET/CT studies before surgery. Post-surgical pathologic examination was used as the standard to determine the final diagnoses. The possibility of bone marrow invasion on MRI, 18F-FDG PET/CT and 18F-FAMT PET/CT were usually graded retrospectively into five-point score. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated according to the obtained scores.

Results

As the sensitivity of 18F-FDG PET/CT was highest (100 %) among that of MRI (95 %) and 18F-FAMT PET/CT (90 %), the specificity of 18F-FAMT PET/CT was highest (85.7 %) among that of MRI (57 %) and 18F-FDG PET/CT (14.3 %). The size of pathological tumor was accorded with that detected by 18F-FAMT PET/CT and was smaller than that detected by 18F-FDG PET/CT (P < 0.01). Significant difference was not found between 18F-FAMT PET tumor volume and pathological tumor volume.

Conclusions

18F-FAMT PET/CT was useful and more specific than MRI or 18F-FDG PET/CT in the detection of bone marrow invasion of OSCC and may contribute to minimize the extent of resection in oral surgery patient.  相似文献   

6.

Purpose

To evaluate the utility of 18F-FDG PET/CT in suspected cerebral pathology in HIV-infected individuals.

Methods

18F-FDG PET/CT scans from 29 HIV-infected individuals (29 brain scans, 22 whole-body scans) who presented with neurological symptoms and signs were retrospectively reviewed and compared with subsequent clinical investigations.

Results

The majority of patients (n?=?25) were referred to differentiate infection from malignant causes of cerebral pathology. Ten of the 11 patients with an eventual diagnosis of toxoplasmosis infection were correctly diagnosed by 18F-FDG PET/CT showing lesional uptake less than that of normal brain cortex (mean SUVmax 3.5, range 1.9 – 5.8). All five patients with a final diagnosis of primary central nervous system lymphoma (PCNSL) were correctly diagnosed by 18F-FDG PET/CT showing lesional uptake greater than that of normal brain cortex (mean SUVmax 18.8, range 12.4 – 29.9). Four of the five patients with 18F-FDG PET/CT features suggesting a vasculitic process had vasculitis confirmed as the final diagnosis. Three patients showed variable uptake in multiple cerebral lesions (including final diagnoses of tuberculosis and metastases from lung cancer in two patients) and there were four other miscellaneous diagnoses. In 12 patients biopsies were performed at sites guided by PET abnormality (7 brain, 5 lymph nodes) confirming or excluding significant disease in 11.

Conclusion

18F-FDG PET/CT is particularly useful for differentiating between infection and PCNSL in HIV-infected patients with a cerebral lesion on MRI or CT. 18F-FDG PET/CT was also a helpful tool in the diagnostic work-up of patients with other HIV-related cerebral pathology. Additional advantages of 18F-FDG PET/CT are the abilities to assess abnormally increased glucose metabolism in the body and to identify potential sites for biopsy.  相似文献   

7.

Purpose

The study evaluated the role of preoperative 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the prediction of recurrent gastric cancer after curative surgical resection.

Methods

A total of 271 patients with gastric cancer who underwent 18F-FDG PET/CT and subsequent curative surgical resection were enrolled. All patients underwent follow-up for cancer recurrence with a mean duration of 24?±?12?months. 18F-FDG PET/CT images were visually assessed and, in patients with positive 18F-FDG cancer uptake, the maximum standardized uptake value (SUVmax) of cancer lesions was measured. 18F-FDG PET/CT findings were tested as prognostic factors for cancer recurrence and compared with conventional prognostic factors. Furthermore, 18F-FDG PET/CT findings were assessed as prognostic factors according to histopathological subtypes.

Results

Of 271 patients, 47 (17?%) had a recurrent event. Positive 18F-FDG cancer uptake was shown in 149 patients (55?%). Tumour size, depth of invasion, presence of lymph node metastasis, positive 18F-FDG uptake and SUVmax were significantly associated with tumour recurrence in univariate analysis, while only depth of invasion, positive 18F-FDG uptake and SUVmax had significance in multivariate analysis. The 24-month recurrence-free survival rate was significantly higher in patients with negative 18F-FDG uptake (95?%) than in those with positive 18F-FDG uptake (74?%; p?18F-FDG uptake was a significant prognostic factor in patients with tubular adenocarcinoma (p?=?0.003) or poorly differentiated adenocarcinoma (p?=?0.0001). However, only marginal significance was shown in patients with signet-ring cell carcinoma and mucinous carcinoma (p?=?0.05).

Conclusion

18F-FDG uptake of gastric cancer is an independent and significant prognostic factor for tumour recurrence. 18F-FDG PET/CT could provide effective information on the prognosis after surgical resection of gastric cancer, especially in tubular adenocarcinoma and poorly differentiated adenocarcinoma.  相似文献   

8.

Purpose

Bone scintigraphy (BS) has been used extensively for many years for the diagnosis of bone metastases despite its low specificity and significant rate of equivocal lesions. 18F-Fluoride PET/CT has been proven to have a high sensitivity and specificity in the detection of malignant bone lesions, but its effectiveness in patients with inconclusive lesions on BS is not well documented. This study evaluated the ability of 18F-fluoride PET/CT to exclude bone metastases in patients with various malignant primary tumours and nonspecific findings on BS.

Methods

We prospectively studied 42 patients (34–88?years of age, 26 women) with different types of tumour. All patients had BS performed for staging or restaging purposes but with inconclusive findings. All patients underwent 18F-fluoride PET/CT. All abnormalities identified on BS images were visually compared with their appearance on the PET/CT images.

Results

All the 96 inconclusive lesions found on BS images of the 42 patients were identified on PET/CT images. 18F-Fluoride PET/CT correctly excluded bone metastases in 23 patients (68 lesions). Of 19 patients (28 lesions) classified by PET/CT as having metastases, 3 (5 lesions) were finally classified as free of bone metastases on follow-up. The sensitivity, specificity, and positive and negative predictive values of 18F-fluoride PET/CT were, respectively, 100?%, 88?%, 84?% and 100?% for the identification of patients with metastases (patient analysis) and 100?%, 82?% and 100?% for the identification of metastatic lesions (lesion analysis).

Conclusion

The factors that make BS inconclusive do not affect 18F-fluoride PET/CT which shows a high sensitivity and negative predictive value for excluding bone metastases even in patients with inconclusive conventional BS.  相似文献   

9.

Purpose

To retrospectively evaluate and compare 18F-FDG, 18F-DOPA and 68Ga-somatostatin analogues for PET/CT in patients with residual/recurrent medullary thyroid carcinoma (MTC) suspected on the basis of elevated serum calcitonin levels.

Methods

Included in the study were 18 patients with recurrent MTC in whom functional imaging with the three tracers was performed. The PET/CT results were compared on a per-patient basis and on a per-lesion-basis.

Results

At least one focus of abnormal uptake was observed on PET/CT in 13 patients with 18F-DOPA (72.2% sensitivity), in 6 patients with 68Ga-somatostatin analogues (33.3%) and in 3 patients with 18F-FDG (16.7%) (p?18F-DOPA and 18F-FDG PET/CT (p?18F-DOPA and 68Ga-somatostatin analogue PET/CT (p?=?0.04). Overall, 72 lesions were identified on PET/CT with the three tracers. 18F-DOPA PET/CT detected 85% of lesions (61 of 72), 68Ga-somatostatin analogue PET/CT 20% (14 of 72) and 18F-FDG PET/CT 28% (20 of 72). There was a statistically significant difference in the number of lymph node, liver and bone lesions detected with the three tracers (p?18F-DOPA PET/CT and 18F-FDG PET/CT (p?18F-DOPA PET/CT and 68Ga-somatostatin analogue PET/CT (p?Conclusion 18F-DOPA PET/CT seems to be the most useful imaging method for detecting recurrent MTC lesions in patients with elevated serum calcitonin levels, performing better than 18F-FDG and 68Ga-somatostatin analogue PET/CT. 18F-FDG may complement 18F-DOPA in patients with an aggressive tumour.  相似文献   

10.

Objective

Recent many studies have shown that whole body “diffusion-weighted imaging with background body signal suppression” (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma.

Methods

Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9?±?2.0 years old) who underwent both 18F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18F-FDG PET/CT and whole-body DWIBS were compared using McNemer’s test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher’s exact test.

Results

The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of 18F-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis.

Conclusion

The specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of 18F-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of 18F-FDG PET/CT. DWIBS should be carefully used for cancer staging in children because of its high incidence of false-positive findings in skeletons.
  相似文献   

11.

Background

Metastatic adrenal disease can occur in a wide diversity of malignancies. Distinguishing benign from metastatic adrenal masses in oncologic patients is vital.

Objective

To appraise the 18F-FDG PET/CT performance for distinguishing benign from metastatic adrenal masses.

Material and methods

In the current prospective study, 21 patients with proven extra-adrenal primary malignancy, having adrenal masses?≥10?mm on the axial CT images of their PET/CT examinations, were enrolled. Positive PET findings for malignancy were considered if the mass showed FDG uptake equivalent to or more prominent than the FDG liver uptake. Alternatively, negative PET findings for malignancy were considered if the mass showed FDG uptake not as much of the FDG liver uptake. Afterward, the obtained results were correlated with serial imaging follow-up or histopathological diagnosis by surgery or percutaneous biopsy as the diagnostic standard of reference.

Results

An overall number of 24 adrenal masses was diagnosed. Positive PET/CT results were found in 14 adrenal masses. All were finally considered to be metastases by serial imaging follow-up (n?=?8) and histopathological analysis by surgery (n?=?1) and percutaneous biopsy (n?=?5). Accordingly, no false positive result was obtained. Negative PET/CT results were observed in 10 adrenal masses, 9 of them were finally confirmed to be benign by serial imaging follow-up. The remaining mass was finally confirmed to be metastasis by percutaneous biopsy and hence, it represented the false negative result. 93% sensitivity, 100% specificity and 96% accuracy for identifying adrenal metastases were obtained.

Conclusion

18F-FDG PET/CT is a precise, non invasive modality for distinguishing benign from metastatic adrenal masses in oncologic patients.  相似文献   

12.

Purpose

IgG4-related disease (IgG4-RD) is an increasingly recognized clinicopathological disorder with immune-mediated inflammatory lesions mimicking malignancies. A cohort study was prospectively designed to investigate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in characterizing IgG4-RD.

Methods

Thirty-five patients diagnosed with IgG4-RD according to the consensus criteria were enrolled with informed consent. All patients underwent baseline 18F-FDG PET/CT evaluation. Among them, 29 patients underwent a second 18F-FDG PET/CT scan after 2 to 4 weeks of steroid-based therapy.

Results

All 35 patients were found with 18F-FDG-avid hypermetabolic lesion(s); 97.1 % (34/35) of these patients showed multi-organ involvement. Among the 35 patients, 71.4 % (25/35) patients were found with more organ involvement on 18F-FDG PET/CT than conventional evaluations including physical examination, ultrasonography, and computed tomography (CT). 18F-FDG PET/CT demonstrated specific image characteristics and pattern of IgG4-RD, including diffusely elevated 18F-FDG uptake in the pancreas and salivary glands, patchy lesions in the retroperitoneal region and vascular wall, and multi-organ involvement that cannot be interpreted as metastasis. Comprehensive understanding of all involvement aided the biopsy-site selection in seven patients and the recanalization of ureteral obstruction in five patients. After 2 to 4 weeks of steroid-based therapy at 40 mg to 50 mg prednisone per day, 72.4 % (21/29) of the patients showed complete remission, whereas the others exhibited > 81.8 % decrease in 18F-FDG uptake.

Conclusion

F-FDG PET/CT is a useful tool for assessing organ involvement, monitoring therapeutic response, and guiding interventional treatment of IgG4-RD. The image pattern is suggested to be updated into the consensus diagnostic criteria for IgG4-RD.  相似文献   

13.

Purpose

Our objectives were to assess the quality of PET images and coregistered anatomic images obtained with PET/MR, to evaluate the detection of focal uptake and SUV, and to compare these findings with those of PET/CT in patients with head and neck tumours.

Methods

The study group comprised 32 consecutive patients with malignant head and neck tumours who underwent whole-body 18F-FDG PET/MR and PET/CT. PET images were reconstructed using the attenuation correction sequence for PET/MR and CT for PET/CT. Two experienced observers evaluated the anonymized data. They evaluated image and fusion quality, lesion conspicuity, anatomic location, number and size of categorized (benign versus assumed malignant) lesions with focal uptake. Region of interest (ROI) analysis was performed to determine SUVs of lesions and organs for both modalities. Statistical analysis considered data clustering due to multiple lesions per patient.

Results

PET/MR coregistration and image fusion was feasible in all patients. The analysis included 66 malignant lesions (tumours, metastatic lymph nodes and distant metastases), 136 benign lesions and 470 organ ROIs. There was no statistically significant difference between PET/MR and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUVmean and SUVmax measured on PET/MR and PET/CT for malignant lesions, benign lesions and organs (ρ?=?0.787 to 0.877, p?<?0.001). SUVmean and SUVmax measured on PET/MR were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p?<?0.05). The main factor affecting the difference between SUVs in malignant lesions was tumour size (p?<?0.01).

Conclusion

In patients with head and neck tumours, PET/MR showed equivalent performance to PET/CT in terms of qualitative results. Comparison of SUVs revealed an excellent correlation for measurements on both modalities, but underestimation of SUVs measured on PET/MR as compared to PET/CT.  相似文献   

14.

Objectives

To compare [18?F]FDG PET/MRI with PET/CT for the assessment of bone lesions in oncologic patients.

Methods

This prospective study included 67 patients with solid tumours scheduled for PET/CT with [18?F]FDG who also underwent a whole-body PET/MRI scan. The datasets (PET/CT, PET/MRI) were rated by two readers regarding lesion conspicuity (four-point scale) and diagnostic confidence (five-point scale). Median scores were compared using the Wilcoxon test.

Results

Bone metastases were present in ten patients (15 %), and benign bone lesions in 15 patients (22 %). Bone metastases were predominantly localized in the pelvis (18 lesions, 38 %) and the spine (14 lesions, 29 %). Benign bone lesions were exclusively osteosclerotic and smaller than the metastases (mean size 6 mm vs. 23 mm). While PET/CT allowed identification of 45 of 48 bone metastases (94 %), PET/MRI allowed identification of all bone metastases (100 %). Conspicuity of metastases was high for both modalities with significantly better results using PET/MRI (p?<?0.05). Diagnostic confidence in lesion detection was high for both modalities without a significant difference. In benign lesions, conspicuity and diagnostic confidence were significantly higher with PET/CT (p?<?0.05).

Conclusions

[18?F]FDG PET/MRI shows high potential for the assessment of bone metastases by offering superior lesion conspicuity when compared to PET/CT. In hypersclerotic, benign bone lesions PET/CT still sets the reference.

Key Points

? PET/MRI and PET/CT are of equal value for the identification of disease-positive patients ? PET/MRI offers higher lesion conspicuity as well as diagnostic confidence ? PET/MRI is an attractive new alternative for the assessment of bone metastases  相似文献   

15.

Purpose

Early detection of infectious endocarditis is challenging. For diagnosing infectious endocarditis, the revised Duke criteria are the gold standard. Evidence of endocardial involvement on echocardiography is a major criterion, but sensitivity and specificity of echocardiography are not optimal. Here we investigated the utility of 18F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) to diagnose infectious endocarditis in patients with gram-positive bacteraemia.

Methods

Seventy-two patients with gram-positive bacteraemia were prospectively included. Patients with a positive blood culture growing Staphylococcus aureus, Streptococcus species or Enterococcus species were eligible when a risk factor for developing metastatic infectious foci was present. Infectious endocarditis was defined according to the revised Duke criteria. All patients underwent 18F-FDG PET/CT and echocardiography. 18F-FDG uptake in or around the heart valves was evaluated independently by two nuclear medicine physicians.

Results

Sensitivity for diagnosing infectious endocarditis with 18F-FDG PET/CT was 39 % and specificity was 93 %. The positive predictive value was 64 % and negative predictive value was 82 %. The mortality rate in patients without infectious endocarditis and without increased 18F-FDG uptake in or around the heart valves was 18 %, and in patients without infectious endocarditis but with high 18F-FDG uptake in or around the heart valves the mortality rate was 50 % (p?=?0.181).

Conclusion

18F-FDG PET/CT is currently not sufficiently adequate for the diagnosis of infectious endocarditis because of its low sensitivity. Improvements such as patient preparation with low carbohydrate–fat allowed diet and technical advances in the newest PET/CT scanners may increase sensitivity in future studies.  相似文献   

16.

Objective

We investigated the prevalence and clinical significance of incidental focal 18F-FDG uptake in the frontal process of the maxilla, mimicking malignancy on PET/CT.

Methods

From a total of 32,834 patients who underwent 18F-FDG PET/CT, patients with focal uptake in the frontal process of the maxilla were selected by a database search. For those patients, medical records including relevant imaging studies were reviewed.

Results

Thirty-nine patients (0.12 %) demonstrated focal uptake on PET/CT. On CT of PET/CT, all lesions showed ground-glass attenuation with or without bony expansion, consistent with fibrous dysplasia. When comparing previous PET/CT, follow-up PET/CT, and CT, a significant difference in degree of 18F-FDG uptake was noted, with no associated change in the size of maxillary lesions. There were no patients who had symptoms or signs related to maxillary lesions during follow-up.

Conclusion

Focal 18F-FDG uptake in the frontal process of the maxilla is a rare, incidental, and persistent finding with variable uptake and can represent a benign condition.
  相似文献   

17.

Objective

The purpose of this study was to evaluate the diagnostic performance of 18F-fluoro-2-deoxy-d-glucose positron emission tomography (FDG PET) as a single imaging agent in neuroblastoma in comparison with other imaging modalities.

Methods

A total of 30 patients with pathologically proven neuroblastoma who underwent FDG PET for staging were enrolled. Diagnostic performance of FDG PET and abdomen CT was compared in detecting soft tissue lesions. FDG PET and bone scintigraphy (BS) were compared in bone metastases. Maximal standardized uptake value (SUVmax) of primary or recurrent lesions was calculated for quantitative analysis.

Results

Tumor FDG uptake was detected in 29 of 30 patients with primary neuroblastoma. On initial FDG PET, SUVmax of primary lesions were lower in early stage (I–II) than in late stage (III–IV) (3.03 vs. 5.45, respectively, p = 0.019). FDG PET was superior to CT scan in detecting distant lymph nodes (23 vs. 18 from 23 lymph nodes). FDG PET showed higher accuracy to identify bone metastases than BS both on patient-based analyses (100 vs. 94.4 % in sensitivity, 100 vs. 77.8 % in specificity), and on lesion-based analyses (FDG PET: 203 lesions, BS: 86 lesions). Sensitivity and specificity of FDG PET to detect recurrence were 87.5 % and 93.8, respectively.

Conclusion

FDG PET was superior to CT in detecting distant LN metastasis and to BS in detecting skeletal metastasis in neuroblastoma. BS might be eliminated in the evaluation of neuroblastoma when FDG PET is performed.  相似文献   

18.

Objective

Endometrial cancer is the most frequent cancer occurring in the female genital tract in the Western countries. Because surgical staging is currently the standard, noninvasive techniques that accurately identify lymph node (LN) metastases would be beneficial by reducing costs and complications. The purpose of our study is to compare the diagnostic accuracy of 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) with that of magnetic resonance imaging (MRI) for detecting LN metastases in the preoperative staging of endometrial cancer.

Methods

Two hundred eighty-seven consecutive patients with endometrial cancer underwent preoperative PET/CT and MRI for staging. The malignancy criteria for LNs were a short diameter of 1 cm or more by MRI and focally increased 18F-FDG uptake by PET/CT. After evaluating PET/CT and MRI separately, morphologic and functional image findings were compared with the histological findings regarding LN metastasis for all patients. PET/CT and MRI images were classified on the basis of histological findings as true-positive, true-negative, false-positive, or false-negative. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated.

Results

Histologic examination revealed LN metastases in 51 patients (17.8 %). The maximal standardized uptake values (SUVmax) of the primary lesions by PET/CT ranged from 1.4 to 37.7, with a mean value of 9.3, whereas those of the metastatic LNs ranged from 2.0 to 22.5 with a mean of 7.3. On a per-patient basis, node staging resulted in sensitivities of 70.0 % with 18F-FDG PET/CT and 34.0 % with MRI, and specificities of 95.4 % with PET/CT and 95.0 % with MRI. The NPV of PET/CT was 94.3 %, and that of MRI was 87.2 %. On a lesion base analysis, sensitivity of PET/CT was 79.4 % while that of MRI was 51.6 %. In detecting distant metastasis, the sensitivity, specificity, accuracy, PPV, and NPV of PET/CT were 92.9, 98.9, 98.6, 81.3, and 99.6 %, respectively.

Conclusion

Diagnostic performance of FDG PET/CT was better than MRI for detecting metastatic lymph nodes in patients with endometrial cancer both by patient basis and lesion basis analyses. Due to high NPV, FDG PET-CT could aid in selecting candidates for lymphadenectomy.
  相似文献   

19.

Purpose

Advanced tumour stage and initial metastases are associated with reduced general and tumour-free survival in patients with differentiated thyroid carcinoma. Optimal initial therapy is mandatory for a positive patient outcome, but can only be performed if all non-iodine-avid tumour lesions are known before planning treatment. We analysed the benefit of 18F-FDG PET/CT at initial diagnosis in patients with high-risk differentiated thyroid carcinoma and determined whether the 18F-FDG PET/CT results led to a deviation from the standard procedure, which consists of two consecutive radioiodine treatments with thyroid hormone suppression in between and no additional imaging, with individual patient management.

Methods

The study group comprised 90 consecutive patients with either extensive or metastasized high-risk differentiated thyroid carcinoma who received 18F-FDG PET/CT after the first radioiodine treatment approximately 4?weeks after thyroidectomy under endogenous TSH stimulation. We carried out PET/CT imaging with low-dose CT without contrast medium, which we only used for attenuation correction of PET images.

Results

18F-FDG PET/CT was positive in 26 patients (29%) and negative in 64 patients (71%). Compared to the results of posttherapeutic 131I whole-body scintigraphy, the same lesions were PET-positive in 7 of the 26 patients, different lesions were PET-positive in 15 patients, and some PET-positive lesions were the same and some were different in 4 patients. TNM staging was changed due to the PET results in 8 patients. Management was changed in 19 of the 90 patients (21%), including all patients with only FDG-positive lesions and all patients with both FDG-positive and iodine-positive lesions. Age was not a predictive factor for the presence of FDG-positive lesions. FDG-positive and iodine-positive lesions were associated with high serum thyroglobulin. However, at low serum thyroglobulin values, tumour lesions (iodine- and/or FDG-avid) were also diagnosed. Thus, the serum thyroglobulin value prior to the first radioiodine treatment cannot be used as a predictor of the presence of FDG-positive lesions.

Conclusion

18F-FDG PET/CT resulted in a change of therapeutic procedure in 11 of 90 patients and in a change of patient management through additional diagnostic measures in 8 of 90 patients, and is consequently very helpful in initial staging. At our hospital, 18F-FDG PET/CT in high-risk patients with differentiated thyroid carcinoma has been established as an initial staging modality.  相似文献   

20.

Purpose

Positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (FDG) has been used with limited success in the past in primary diagnosis and locoregional staging of urinary bladder cancer, mainly because of the pharmacokinetics of renal excretion of 18F-FDG. In the present prospective study, we have evaluated the potential application of diuretic 18F-FDG PET/CT in improving detection and locoregional staging of urinary bladder tumours.

Methods

Twenty-five patients suspected of having primary carcinoma of the urinary bladder were evaluated prospectively for diagnosis and staging. All of these 25 patients underwent conventional contrast-enhanced computed tomography (CECT) of the abdomen/pelvis and whole-body diuretic 18F-FDG PET/CT. In addition, pelvic PET/CT images were obtained using the special technique of forced diuresis using intravenous furosemide (20–40 mg). Of the 25 patients, 10 underwent radical cystectomy and 15 underwent transurethral resection of the bladder tumour (TURBT). Results of CECT and diuretic 18F-FDG PET/CT were compared considering histopathology as a reference standard.

Results

Of the 25 patients, CECT detected a primary tumour in 23 (sensitivity 92 %), while 18F-FDG PET/CT was positive in 24 patients (sensitivity 96 %). Mean size and maximum standardized uptake value of the bladder tumours were 3.33 cm (range 1.6–6.2) and 5.3 (range 1.3–11.7), respectively. Of the 25 patients, only 10 patients underwent radical cystectomy based on disease status on TURBT. Among those ten patients, nine had locoregional metastases. Among the nine patients who had positive lymph nodes for metastasis on histopathology, CECT and PET/CT scan had a sensitivity of 44 and 78 %, respectively. 18F-FDG PET/CT was found to be superior to CECT in the detection of the primary tumour and locoregional staging (p?<?0.05).

Conclusion

Diuretic 18F-FDG PET/CT is highly sensitive and specific and plays an important role in improving detection of the primary tumour and locoregional staging of urinary bladder tumours. Diuretic 18F-FDG PET/CT demonstrated a higher diagnostic value when compared with CECT in these patients.  相似文献   