相似文献
 共查询到18条相似文献,搜索用时 171 毫秒
1.
62 金属伪影 与梯度回波(图62D)序列相比,自旋回波(图62A)和快速自旋回波(图62B)序列由于180°的回聚脉冲,使图像畸变更少。图62C中所有成像方式扩散加权成像均有畸变伪影。但在这个例子中,并行成像明显地减少了伪影。3DTOF法对Willis氏动脉环扫描(最大密度投影法,图62F)  相似文献   

2.
节育器与磁共振检查伪影的研究   总被引:1,自引:0,他引:1  
马红强 《医疗装备》2010,23(2):12-13
目的:检测不同材料的节育器在磁共振检查中是否产生伪影和伪影的严重程度,并比较不同检查序列对伪影的影响。材料:对12种常见节育器做了磁共振成像测试,磁共振仪磁场1.5T,所用序列为快速梯度回波和自旋回波、快速自旋回波。结果:带铜金属单环、硅VCu200、药铜环165、带铜宫型腔节节育器、安塑铜环250、活性7型节育器6种有严重金属伪影。TCu220c、TCu200、TCu380A、TCu380Ag、母体乐铜节育器、可塑性铜套节育器6种没有金属伪影,带铜金属单环、药铜环165、带铜宫型腔节育器3种节育器在FFE序列中伪影比TSE、SE更为明显。结论:相"-3部分的节育器在磁共振检查中会引起严重伪影,影响图像质量,所以在检查女性盆腔、腹部、腰椎等位置时,须引起重视。对于轻度伪影通过选择合理的成像序列和参数减轻伪影,对于影响诊断的,采取摘除节育器后再做磁共振成像检查。  相似文献   

3.
肖建明 《医疗设备信息》2012,(5):138-139,147
目的探讨消除腰椎MRI检查时椎间盘多平面多角度T2WI序列出现带状低信号伪影的可行方法。方法应用SIEMENS AVANTO 1.5T磁共振扫描仪,对42例临床怀疑腰椎间盘突出患者行腰椎常规矢状位和横断位多角度多平面扫描,采用快速自旋回波(TSE)序列、快速恢复快速自旋回波(TSE-Restore)序列,并由3名高年资医师对图像质量进行评价。结果 2种方法都能完全消除伪影,且图像质量完全符合诊断要求。结论快速恢复快速自旋回波联合分段扫描技术是最优化消除饱和伪影的方法。  相似文献   

4.
胡斌 《医疗设备信息》2000,15(4):30-31,33
本文通过对K空间与自旋回波技术、快速自旋回波技术、部门K空间、钥孔成像及呼吸和运动伪影补偿等基本技术关系的描述,探讨参数的选择应根据需要调整,才能真正保证MR图像的有效质量。  相似文献   

5.
49心脏形态成像搏动器官和组织的常规自旋回波系列(SE)和快速自旋回波序列(FSE)成像,例如心脏的成像,在正常的心动周期内,由于心脏组织空间位置的快速变化,在标准形式下获得的心脏成像就会表现出运动伪影。但是,由于正常的心动周期是连续性的,并且包含较短的不动期和舒张期,只有在这些时期内才能更改标准序列来获得信息,该过程称为心脏触发,在该过程中,在一个层面的k空间被填满之前,涉及在每一个心脏舒张期获取一条带有k空间线的回波(SE),  相似文献   

6.
曾豪  李文晋 《现代保健》2014,(6):152-154
磁共振成像(MRI)技术是目前影像科常用的诊断方法,主要用于颅脑和头颈部疾病的诊断。口腔科修复用的金属及合金材料种类繁多,其中一些材料在MRI图像中会产生伪影,造成信号强度减弱或图像变形或无信号区,干扰正常的解剖学结构和病理组织形态,影响临床诊断。本文就常用的口腔金属材料与磁共振成像的关系进行综述,以供临床使用。  相似文献   

7.
张法轮  施展 《医疗装备》2023,(22):110-112+115
<正>伪影是指医学图像上出现的某些结构或信号强度,但被成像物体中并无与之对应的解剖学结构。伪影是由成像技术产生的,主要表现为图像变形、模糊、叠加或缺失[1]。磁共振成像过程中,伪影问题时有发生。如卷褶伪影、交叉伪影、截断伪影和容积效应伪影是由不合适的序列或参数造成的,化学位移伪影是磁共振成像固有的,运动伪影和金属异物伪影与患者有关[2]。多数伪影可通过优化序列参数或规范操作进行改善。  相似文献   

8.
磁共振成像时,运动和流动伪影常严重降低图像质量,二者产生的机制非常复杂。对运动和流动伪影的前处理抑制技术,包括改变磁共振成像参数、使用空间预饱和脉冲、抑制呼吸运动伪影的门控和触发等技术,以及抑制运动和流动伪影的磁共振成像序列的进展等进行描述,并简要介绍了磁共振运动和流动伪影的后处理矫正技术。  相似文献   

9.
磁共振多线圈并行采集技术是提高成像速度行之有效的方法之一,还可通过缩短回波链长度减少成像的畸变和敏感性伪影,临床应用十分广泛。讨论了iPAT并行成像技术的成像机理、临床应用及合理选择。  相似文献   

10.
的探索不同体积ITI种植体在3.0T磁共振成像(MRI)检态中的伪影影响。方法将同一直径不同长度的两枚TTI种植体分别固定在志愿者两侧下颌骨皮肤表面,做MRI测试。磁共振仪磁场强度为3.0T,采用TSE,EPI序列。结果两枚种植体都能在MRI检查中产生伪影,影响局部区域成像质量,其中体积较大的种植体产生的伪影更大。结论纯钛TTI种植体在MRI检查中,对其周嗣软组织成像有一定影响,并且伪影面积大小与种植体体积有关。  相似文献   

11.
目的:探讨颈椎钛合金术后MRI扫描参数的优化,以降低磁化率伪影。方法:提出以分组的方式,按照3级评分标准,对10例颈椎钛合金术后患者行MRI检查(5例前路固定,5例后路固定),患者均行矢状位、轴位:T1,T2加权成像(T1WI,T2WI)。其中部分扫描改变频率编码方向,TE值,空间分辨率,序列进行对比。分别对各组图像中磁化率伪影大小进行评判。结果:伪影在T1、T2加权像均呈低信号,其边缘分界线呈高信号;频率编码方向与钛合金长轴主轴平行时产生的伪影小于两者垂直时;TE取值越小,伪影越轻微;分辨率越高,伪影越轻微;梯度回波伪影比快速自选回波伪影严重。结论:在不增加病人风险的前提下,选择合适的扫描序列,合理优化扫描参数,可以有效降低磁化率伪影。  相似文献   

12.
目的:探讨无相位卷褶技术在磁共振成像中的应用。方法:选择性对139例受检者进行解剖结构大小超过相位方向视野(FOV)范围的扫描。在其它条件相同的前提下,分别进行使用NPW技术和不使用NPW技术2个序列检查。结果:相同条件下,不使用NPW技术上述所有图像出现相位卷褶伪影;使用NPW技术则卷褶伪影消失。结论:使用NPW技术可防止卷褶伪影的发生。  相似文献   

13.
Rabbits were exposed to 0.6 mg/m3 of nickel as NiCl2 for about one month. After exposure, alveolar macrophages were lavaged from the lung and divided into three fractions by elutriation. Laminated structures in the macrophages were related to fraction number so that the fractions with the largest cells contained the highest number of structures. The lysozyme activity decreased in unfractionated as well as in fractionated macrophages from nickel exposed rabbits. The decrease was most pronounced in the fraction with the smallest macrophages and smallest number of laminated structures. Therefore the pronounced decrease in lysozyme activity seen in this and earlier studies is not caused by the increased amount of surfactant material. Increased amount of surfactant is a hallmark of nickel inhalation exposure and the surfactant material is responsible for the morphological and metabolic effects of the macrophages. The decreased lysozyme activity is probably a direct effect of nickel on the macrophages.  相似文献   

14.
Rabbits were exposed to 0.6 mg/m3 of nickel as NiCl2 for about one month. After exposure, alveolar macrophages were lavaged from the lung and divided into three fractions by elutriation. Laminated structures in the macrophages were related to fraction number so that the fractions with the largest cells contained the highest number of structures. The lysozyme activity decreased in unfractionated as well as in fractionated macrophages from nickel exposed rabbits. The decrease was most pronounced in the fraction with the smallest macrophages and smallest number of laminated structures. Therefore the pronounced decrease in lysozyme activity seen in this and earlier studies is not caused by the increased amount of surfactant material. Increased amount of surfactant is a hallmark of nickel inhalation exposure and the surfactant material is responsible for the morphological and metabolic effects of the macrophages. The decreased lysozyme activity is probably a direct effect of nickel on the macrophages.  相似文献   

15.
罗锐锋 《现代保健》2012,(16):88-89
目的 观察海洛因所致海绵状脑白质病的MRI 表现及其诊断价值.方法 对本院收治的13 例吸食海洛因所致海绵状脑白质病的患者用0.2T 永磁型MR 仪进行MRI 检查,检查序列为自旋回波(SE)T1WI、快速自旋回波(FSE)T2WI 及反转恢复FIR,观察患者MRI表现特征.结果 13 例患者均可见脑内白质双侧对称性异常病变,累及部位包括小脑半球、大脑半球脑白质、内囊后肢、胼胝体压部和膝部;MRI 检查T1WI 均呈低信号,T2WI 与FIR 序列均表现为均匀或不均匀的高信号;受累部位以小脑半球白质最为严重,而灰质核团则未见受累.结论 海洛因所致海绵状脑白质病在MRI 检查中具有典型特征表现,结合临床病史,MRI 对此病的诊断具有特异性.  相似文献   

16.
螺旋桨技术及其在头部磁共振扫描中的应用   总被引:4,自引:0,他引:4  
周学军  曹亮 《医疗设备信息》2006,21(9):91-93,96
探讨螺旋桨扫描技术(Periodically Rotated Overlapping ParallEL Lines Enhanced Reconstruction,Propeller)在颅脑MRI扫描中的应用价值。收集我院05年5-12月颅脑MRI检查病人300例得出扫描中应用螺旌桨技术进行T2-WI、T2flair-WI序列扫描,能有效地减少颅脑因运动或金属异物造成的MRI伪影,提高图像质量,可作为颅脑MRI扫描的常规序列。  相似文献   

17.
分析了MRI伪影的产生机理及采取相应补偿技术并判断是否有效。使用1.0T和1.5T的MRI扫描患者或水模,从改善外界环境、校正软硬件、修改参数或训练患者等角度采取各种补偿技术消除伪影。使伪影得到不同程度的控制,多数图像质量改善明显。通过相应补偿技术,多数伪影可以完全消除,有些伪影仅能减少或位置改变。  相似文献   

18.
功能MRI的伪影校正方法   总被引:1,自引:0,他引:1  
分析对功能MRI数据分析影响较为严重的头部运动伪影、生理运动伪影、血流伪影、ghost伪影及敏感性伪影的产生机制,综述现有的伪影校正方法,并提出功能MRI伪影校正方法研究的一些新方向.  相似文献   