首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To compare the myocardial uptake pattern of 99mTc-labeled methoxyisobutyl isonitrile [( 99mTc] MIBI) and 201TI, planar scintigraphy were performed in both patients with documented coronary artery disease and subjects with a low likelihood of disease. Quantitative analysis was employed using a standard interpolative background subtraction algorithm and a new algorithm modified to better accommodate for the differences in extracardiac activity seen with [99mTc]MIBI rest images. Among patients with coronary artery disease, the standard algorithm yielded no significant difference in relative defect magnitude between [99mTc]MIBI and 201TI on stress scintigrams (p = 0.48), although the magnitude of [99mTc]MIBI defects was greater on resting images (p = 0.02). When the modified algorithm was employed, defect magnitude was similar for both stress (p = 0.91) and rest (p = 0.20) images. Normal segmental uptake ratios derived from a comparison of contralateral segments (e.g., septal:posterolateral) in the low likelihood patients were similar for both [99mTc]MIBI and 201TI. Thus, modification of the standard interpolative background subtraction algorithm is necessary for quantitative planar [99mTc]MIBI perfusion imaging. When appropriate background subtraction is employed, myocardial uptake and quantitative defect magnitude of [99mTc]MIBI and 201TI planar images are similar.  相似文献   

2.
Resting first-pass radionuclide angiography (FPRNA) was performed with the myocardial perfusion agent technetium-99m MIBI. In 27 patients, it was compared with technetium-99m diethylenetriamine pentaacetic acid FPRNA. A significant correlation was present in left (r = 0.93, p less than 0.001) as well as right (r = 0.92, p less than 0.001) ventricular ejection fraction measured with both radiopharmaceuticals. In 13 patients, MIBI derived segmental wall motion was compared with contrast ventriculography. A high correlation was present (p less than 0.001), and qualitative agreement was found in 38/52 segments. In 19 patients with myocardial infarction a significant correlation was present between MIBI segmental wall motion and perfusion scores (p less than 0.001). In ten patients with a history of myocardial infarction, 18 myocardial segments demonstrated diseased coronary vessels and impaired wall motion at contrast angiography. These segments were all identified by the MIBI wall motion and perfusion study. We conclude that MIBI is a promising agent for simultaneous evaluation of cardiac function and myocardial perfusion at rest.  相似文献   

3.
Hexakis (2-methoxy isobutylisonitrile) technetium-99m [(99mTc]MIBI), a new tracer of myocardial blood flow, was compared with 201TI CI in cultures of myocardial cells of newborn rats. The kinetics of uptake and release of both tracers were assessed in basal conditions and in the presence of 5 mM cyanide, an inhibitor of the respiratory chain, 0.1 mM iodoacetate, an inhibitor of glycolysis, 10 microM ouabain, an inhibitor of the Na-K ATPase, or with various pH values. The amplitude and frequency of contractions of the cells were also monitored in the same conditions. Results show that the washin and washout kinetics of [99mTc]MIBI are slower than 201TI(T1/2) of the washout curves were, respectively, of 28 min and 6 min). The kinetics of release of both tracers were not influenced by any of the inhibitors. There was a strong effect of the pH on the 201TI uptake only. Moreover 201TI uptake was decreased by 34% in the presence of cyanide plus iodoacetate. Otherwise the uptakes of 201TI and [99mTc]MIBI were not decreased by any of the drugs. The cellular contractility was significantly diminished by cyanide and it was abolished by cyanide plus iodoacetate. It is concluded that (a) impaired contractility can be associated with normal 201TI and [99mTc]MIBI kinetics in myocardial cells in culture, (b) that 201TI uptake may depend on the level of ATP devoted to the maintenance of membrane integrity, (c) that [99mTc]MIBI shows slower kinetics but is less sensitive to metabolic inhibitors than 201TI.  相似文献   

4.
Extensive work has already been performed with regard to both planar and single photon emission computed (SPECT) technetium 99m sestamibi studies. Before widespread application of optimized acquisition and processing methods, clinical results between 99mTc sestamibi and thallium 201 were remarkably similar. It is anticipated that as techniques for 99mTc sestamibi planar and SPECT imaging become optimized, improvements in sensitivity and specificity for detection of coronary artery disease, over those observed with 201TI, might be forthcoming. This expectation is based on the improved image quality inherent in the use of the 99mTc agent with its higher count rate and higher energy. This improvement in image quality may be a principal reason for laboratories to switch from 201TI to 99mTc sestamibi imaging. It is anticipated that, with improved imaging characteristics, it will be easier for the average community hospital to obtain higher quality planar or SPECT imaging using 99mTc sestamibi rather than 201TI. In addition to improved image quality, the characteristics of 99mTc sestamibi allow gated planar or SPECT perfusion images to be obtained. It has been suggested that stress-gated SPECT sestamibi studies may provide all the information contained in a stress-rest nongated 99mTc sestamibi study, thereby potentially increasing patient throughput, a major concern with SPECT. Throughput can also be increased by using dual-isotope approaches with rest 201TI and stress technetium sestamibi acquisitions, employing either separate or simultaneous imaging with which the entire study can be accomplished in less than 2 hours. With simultaneous dual-isotope acquisition, camera time can be reduced by 50%. Finally, 99mTc sestamibi offers the advantage of the ability to perform first-pass exercise ventricular function and SPECT myocardial perfusion studies with a single injection of tracer. Regarding the assessment of myocardial viability, results to date suggest a very high degree of concordance between 201TI and 99mTc sestamibi studies using either planar or SPECT acquisition techniques. Correlative rest studies with both tracers will be of particular interest, as will preoperative and postoperative and position emission tomography correlation studies.  相似文献   

5.
The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. Conclusions: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.  相似文献   

6.
This study assesses feasibility and diagnostic accuracy of simultaneous stress 99mTc-sestamibi/rest 201 TI dual-isotope myocardial perfusion SPECT with Moore's correction method, in which contamination originating from lead x-rays produced in a collimator was subtracted in the 201TI windows. METHODS: Eighty-one patients with suspected coronary artery disease received exercise 99mTc-sestamibi injection, followed by rest 201TI injection 50 min later, and dual-isotope SPECT was performed (group 1). These results were compared with coronary angiographic findings. Furthermore, to estimate the accuracy of Moore's correction method, 201TI crosstalk into the 99mTc acquisition window (group 2A, n = 20) and 99mTc crosstalk into the 201TI acquisition windows (group 2B, n = 20) were studied. For group 2A, stress 99mTc-sestamibi SPECT (single 99mTc-sestamibi SPECT) was performed, followed by 201TI injection at rest and dual-isotope SPECT acquisition 50 min later. For group 2B, rest 201TI SPECT (single 201TI SPECT) was performed, followed by 99mTc-sestamibi injection at rest and dual-isotope SPECT acquisition 30 min later. RESULTS: Sensitivity and specificity in group 1 were 83% and 99%, respectively, when > or =75% coronary artery narrowing was considered significant. In groups 2A and 2B, SPECT images were divided into 24 segments, and relative regional uptake in each segment was obtained. In group 2A, relative regional uptake of single 99mTc-sestamibi SPECT correlated well with that of dual-isotope SPECT (r = 0.942). In group 2B, relative regional uptake of single 201TI SPECT correlated well with that of dual-isotope SPECT (r = 0.935). Furthermore, in low 201TI uptake segments with relative regional uptake in both single- and dual-isotope SPECT of < or =70%, the degree of concordance between single- and dual-rest 201TI was considered to be high with Bland-Altman analysis and the kappa statistic. Comparison of perfusion defect type demonstrated that, of 22 stress defects within infarct zones, 95% were irreversible and 5% were reversible. In contrast, of 28 stress defects within stenosed vessel zones in noninfarct zones, 89% were reversible and 11% were irreversible (P < 0.0001 versus infarct zones). CONCLUSION: Simultaneous dual-isotope imaging with Moore's correction method is feasible, with acceptable accuracy for detection of coronary artery disease and a small amount of crosstalk into each window.  相似文献   

7.
With technetium-99m 2-methoxy-isobutyl-isonitrile (99mTc-MIBI), regional wall thickening in a patient with dilated cardiomyopathy was analyzed by the first component Fourier method. The regional wall thickening was compared with thallium-201 and 99mTc-MIBI SPECT imaging. Thallium-201 SPECT images showed mildly reduced perfusion in the posterior wall and redistribution in the septum, whereas 99mTc-MIBI images showed heterogeneous accumulation around the left ventricular circumference. By means of phase analysis, diffusely decreased wall thickening and discontinuity of percent wall thickening in neighboring segments were observed throughout the left ventricle. Regional wall motion and wall thickening correlated roughly. However, discrepancies between the mechanical function and myocardial perfusion, and discrepancies in regional myocardial perfusion between thallium-201 and 99mTc-MIBI were observed.  相似文献   

8.
BACKGROUND: Technetium-labeled myocardial perfusion tracers allow simultaneous assessment of myocardial perfusion and left ventricular function by electrocardiography (ECG)-gated myocardial single photon emission computed tomography (SPECT). The purpose of this study was to evaluate left ventricular performance during dobutamine stress by means of ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS AND RESULTS: After administration of Tc-99m sestamibi or tetrofosmin (600-740 MBq), 67 patients with ischemic heart disease, including 35 with prior myocardial infarction, were examined by ECG-gated myocardial perfusion SPECT at rest and during dobutamine stress (at dosages of 4, 8, 12, 16, and 20 microg/kg/min, with increments every 8 minutes). The ECG-gated data collection time was 5 minutes for each dobutamine dosage. After acquisition of gated SPECT data at the highest dose, thallium 201 chloride (111 MBq) was injected, and dual-isotope SPECT was also performed to assess the myocardial ischemia. In 32 patients without prior myocardial infarction, the sensitivity of individual stenosed-vessel detection with dual-isotope perfusion SPECT, with wall motion abnormality obtained from gated SPECT, and with the combined method was 55.9%, 52.9%, and 73.5%, respectively, based on coronary angiography. ECG-gated SPECT during dobutamine infusion revealed regional wall motion abnormalities (worsening or biphasic response) in 19 (57.6%) of 33 infarcted areas with culprit coronary arterial stenosis. The prevalence of reversible perfusion defects on dual-isotope SPECT was higher in segments with wall motion abnormalities than in segments with normal wall motion response (89.5% vs 42.9%, P <.02). CONCLUSIONS: Myocardial perfusion and left ventricular function during dobutamine infusion were analyzed in a single examination by means of the combined method. This procedure has the potential to provide comprehensive information with which to evaluate patients with ischemic heart disease.  相似文献   

9.
目的 探讨高血压病心肌显像异常的临床意义及与心律失常的关系。方法 对 88例高血压患者行99Tcm 甲氧基异丁基异腈心肌灌注断层显像 ,对其中 5 7例显像异常者再行硝酸甘油介入心肌显像。所有患者均行Holter检查 ,冠状动脉造影 31例。结果 运动和静息显像后仍有 6 4 8%患者灌注减低 ,6 0 2 %的灌注减低节段硝酸甘油介入显示有填充或不完全填充 ,提示合并冠心病。多因素逐步回归分析表明 ,室性心律失常与心肌灌注减低的程度及左室肥厚 (LVH)呈线性回归关系。结论 心肌灌注断层显像及硝酸甘油介入心肌显像能反映高血压患者是否合并冠心病 ,并与其他高血压性病理改变所致的灌注减低相区别。高血压合并冠心病及LVH是心律失常的重要病理基础。  相似文献   

10.
We investigated whether poststress gated SPECT, which was believed to show resting wall motion, revealed stunning induced by dipyridamole stress. METHODS: In 62 patients with coronary artery disease (n = 57) or chest pain (n = 5), dipyridamole stress gated 99mTc-hexakis-2-methoxyisobutyl isonitrile (MIBI) SPECT and rest 201Tl SPECT were performed on the first day; 24-h delayed 201Tl SPECT and rest gated 99mTc-MIBI SPECT were performed on the second day. Stress and rest gated 99mTc-MIBI SPECT was performed 1 h after injection. The myocardium was divided into 17 segments, and perfusion was scored on a 4-point scoring system (scores, 0-3 for normal to defect); wall motion during first-day poststress gated and second-day rest gated SPECT was also scored on another 4-point scale (scores, 0-3 for normal to dyskinesia). RESULTS: Thirty-one of 62 patients showed wall motion abnormality that was worse after stress than during resting. Three hundred eight (29%) of the total 1054 segments showed wall motion abnormality on poststress gated SPECT. In 198 of these segments, wall motion abnormality was the same on poststress and rest gated SPECT, and 106 segments showed wall motion that was worse on 1-h poststress than on rest gated SPECT. Perfusion was normal either during rest (n = 113) or after a 24-h delay (n = 18) in 131 segments with the poststress wall motion abnormality. Of these 131 segments, 69 showed the same wall motion abnormality between poststress and resting periods (persistent stunning). However, in 40 segments, abnormal wall motion on 1-h poststress gated SPECT normalized on rest gated SPECT (transient prolonged stunning). The other 20 segments showed improvement of wall motion during rest compared with the poststress period but still showed abnormal wall motion during the resting period (between transient prolonged stunning and persistent stunning). Stress perfusion decrease was more severe in transient prolonged stunning than in persistent stunning. Poststress wall motion abnormality was more severe in persistent stunning. CONCLUSION: Using gated 99mTc-MIBI SPECT, stunned myocardium was found on 1-h poststress SPECT compared with normal resting wall motion found on rest gated SPECT on the next day. We conclude that some myocardial walls did not show true resting wall motion on 1-h poststress gated SPECT; hence, caution is necessary when using wall motion on 1-h poststress gated SPECT to assess resting wall motion.  相似文献   

11.
Tc-99m MIBI myocardial SPECT has shown promise for evaluation of coronary artery disease. But its role in predicting myocardial viability is still under investigation. The purpose of this study was to evaluate the value of Tc-99m MIBI myocardial SPECT during isosorbide dinitrate (ISDN) infusion in the assessment of myocardial viability. Thirty-seven patients with previous myocardial infarction (the infarct age ranged from ≤ 30 days to 900 days) were studied, of them 13 patients had Tc-99m MIBI studies before and after coronary artery bypass grafting (CABG). The results showed that out of 134 segments with hypoperfusion at resting SPECT, 56 segments (41.8%) had an increase in Tc-99m MIBI uptake during ISDN infusion. Among them, 17 segments (30.4%) were normalized, 6 segments (10.7%) were significantly improved and 33 segments (58.9%) were improved. The degree of improvement in perfusion was related to the age of the myocardial infarction. In 13 patients with CABG, of 31 segments with improvement in perfusion post CABG, 25 segments (80.6%) showed perfusion improvement during ISDN infusion, and of 28 segments with improved wall motion post CABG, 23 segments (82.1 %) showed improvement in perfusion during ISDN infusion. Tc-99m MIBI SPECT during ISDN infusion may therefore be a useful approach for assessing myocardial viability.  相似文献   

12.
PURPOSE: TI-201 scintigraphy is plagued with poor image quality because of the low-energy photons of TI-201 decay. Traditionally, a narrow 20% window centered on 71-72 keV has been used to improve sensitivity. Recent studies indicate that better imaging may be possible by optimizing the energy window to 34% centered on 77 keV. In this study, energy window optimization (EWO) was applied to gated TI-201 myocardial perfusion SPECT, and myocardial functional parameters were compared for gated TI-201 SPECT and gated Tc-99m sestamibi (Tc-99m MIBI) SPECT. METHODS: Count statistics for standard and optimal TI-201 myocardial scintigraphy were noted in 25 patients by assessing the total counts in a mid-ventricular slice of a rest-gated TI-201 myocardial SPECT study. The feasibility of performing functional studies with the application of EWO to TI-201 was assessed using the count statistics of a mid-ventricular slice of an optimized gated TI-201 SPECT study and a gated Tc-99m MIBI SPECT study. The functional parameters (ejection fraction, wall motion, and thickening) of TI-201 with EWO and Tc-99m MIBI were compared in 60 patients who underwent rest-gated TI-201 SPECT followed by poststress gated Tc-99m MIBI SPECT. The left ventricular ejection fraction was calculated using commercially available software, whereas wall thickness and motion were assessed by the consensus of two readers. RESULTS: The application of EWO increased available counts by more than 25%. It also resulted in sufficient counts being available to perform gated TI-201 SPECT without increasing acquisition times or the dose of TI-201. The average ejection fraction was 60.4% for gated TI-201 SPECT and 59.6% for gated Tc-99m MIBI SPECT (not significantly different). Overall, the image quality was rated excellent in 12% for TI-201 and Tc-99m MIBI and good in 50% and 62%, respectively, and poor in 38% and 26%, respectively. CONCLUSION: The application of EWO to TI-201 SPECT allows myocardial functional parameters to be assessed without having to increase the acquisition times or the administered dose of TI-201.  相似文献   

13.
A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly.  相似文献   

14.
A 74-year-old man with a history of diabetes and arterial hypertension, presented with right ventricular failure, remarkable jugular venous distension, hepatomegaly, and swelling of the lower extremities. He was complaining of atypical chest pain and was referred for an echocardiogram and a myocardial perfusion SPECT imaging study. The echocardiogram showed normal left ventricular function with a dilated right atrium and right ventricle, severe tricuspid regurgitation, pulmonary hypertension, and an atrial septal defect with bidirectional shunt. The SPECT images showed normal left ventricular function with no areas of induced ischemia but an impressive right ventricle with severe dilatation and hypertrophy. A right ventricular "perfusion abnormality," consistent with ischemic changes, seen on stress but less evident on rest images was demonstrated on the dual isotope (Tl-201 rest/Tc-99m MIBI stress) protocol but not seen on the single isotope study (rest/stressTc-99m MIBI). Coronary angiogram showed diffuse coronary atherosclerosis but without significant obstruction.  相似文献   

15.
双核素心肌显像检测存活心肌的对比研究   总被引:2,自引:0,他引:2  
目的 对比多巴酚丁胺负荷201Tl/静息99Tcm-甲氧基异丁基异腈(MIBI)双核素同步心肌断层显像及多巴酚丁胺负荷-再分布/再注射201Tl心肌断层显像法检测存活心肌的作用.方法 对160例临床怀疑有冠心病的患者予静息状态下静脉注射740 MBq99Tcm-MIBI,休息15 min后进行多巴酚丁胺负荷试验,在达到终止指标时静脉注射111 MSq201TICI.注射后观察5-lO min,分别行早期(10 min)、延迟(3 h)99Tcm-MIBI和201Tl双核素同步心肌断层显像.对早期负荷201Tl图像发现放射性缺损,延迟再分布201Tl和静息99Tcm-MIBI图像未见放射性填充的患者再注射37 MBq201TICI,30min后行再注射心肌灌注显像.负荷枷201Tl图像示放射性缺损,静息99Tcm-MIBI、再分布201Tl及再注射201Tl图像中发现任何一种放射性填充者均为存活心肌.断层显像后2周内全部患者进行了冠状动脉造影.采用SAS 6.12软件进行x2检验.结果 (1) 160例患者冠状动脉造影均发现冠状动脉狭窄.其中单支病变76例、双支病变5l例、三支病变33例.(2)152例多巴酚丁胺负荷201Tl图像发现放射性缺损的患者中,63例201Tl再分布和静息99Tcm-MIBI图像均发现放射性填充,5例201Tl再分布发现放射性填充而静息99Tcm-MIBI图像未见放射性填充,9例静息99Tcm-MIBI图像发现放射性填充而2001Tl再分布未见放射性填允,75例201Tl再分布和静息99Tcm-MIBI图像均未发现放射性填充,负荷201Tl-延迟再分布显像(66.0%,68/103)和负荷201Tl/静息99Tcm-MIBI显像(69.9%,72/103)鉴别存活心肌的灵敏度差异无统计学意义(x2=O.36,P>0.05).(3)75例201Tl再分布和静息99Tcm-MIBI图像均未发现放射性填充患者中,再注射201Tl显像后有26例放射性填充,再注射201Tl显像较单纯201Tl再分布或静息99Tcm-MIBI显像多检测出34.7%(26/75)患者有存活心肌.(4)8例多巴酚丁胺负荷201Tl、201Tl再分布图像和静息99Tcm-MIBI图像均未发现放射性稀疏,为假阴性,其中3例为三支冠状动脉病变,1例为双支冠状动脉病变(狭窄分别为90%及60%),3例为单支冠状动脉病变(狭窄<75%2例,85%1例),1例冠状动脉闭塞后有充分的侧枝循环.结论 多巴酚丁胺负荷-再分布/再注射201Tl心肌断层显像鉴别存活心肌优于多巴酚丁胺负荷201Tl/静息99Tcm-MIBI双核素同步心肌断层显像,是一种有效、无创的鉴别存活心肌的方法.  相似文献   

16.
To assess both ventricular function and myocardial perfusion, five normal volunteers, 19 patients with coronary artery disease, and two patients with cardiomyopathy and normal coronary arteries were injected with 20 mCi of Tc-99m isonitrile (either methoxyisobutyl isonitrile or carbomethoxyisopropyl isonitrile) at peak bicycle exercise and again at rest. A standard Tl-201 stress test was performed in all patients at the same level of exercise within one month of the isonitrile study. In all normal subjects, myocardial perfusion was normal at stress levels and the left ventricular ejection fraction increased 5% or more with exercise. In the 19 patients with coronary artery disease, the ejection fraction response to exercise was abnormal in 14 patients. Perfusion images with the Tc-99m isonitriles correlated well with Tl-201 images during exercise and at rest, with 89% concordance in areas of ischemia or infarction and 93% in normal segments. A simultaneous study of myocardial perfusion and ventricular function can be performed using a single Tc-99m labeled myocardial agent. Tc-99m isonitriles, particularly Tc-99m MIBI, result in sufficiently high photon flux that ventricular performance can be studied at peak exercise and again during rest using the first pass method.  相似文献   

17.
The aim of this study was to assess whether or not myocardial uptake of Technetium-99m methoxy isobutyl isonitrile (Tc-MIBI) indicated myocardial viability. We performed simultaneous Tc-MIBI angiography and myocardial SPECT at rest on 12 patients with suspected coronary artery disease. Left ventricle was divided into 3 segments, and regional wall motion was graded as normal, hypokinesis and akinesis/dyskinesis. Myocardial uptake of Tc-MIBI was assessed as normal, reduced and absent in each segment. In segments with normal and reduced Tc-MIBI uptake, 7% (2 of 28) and 33% (2 of 6) showed wall motion abnormalities of akinesis/dyskinesis, respectively. However, all segments with absent Tc-MIBI uptake had asynergy of akinesis/dyskinesis (2 of 2, 100%). Myocardial Tc-MIBI uptake at rest indicated wall motion abnormalities and was considered to be useful for the evaluation of myocardial viability. First-pass radionuclide angiography followed by myocardial SPECT with Tc-MIBI demonstrated to be useful for the simultaneous assessment of the left ventricular wall motion and myocardial perfusion.  相似文献   

18.
PURPOSE: It is possible to simultaneously evaluate wall thickening and perfusion abnormalities with radionuclide techniques that use tracers such as Tc-99m MIBI. We presumed that detection of wall thickening by gated MIBI SPECT imaging in the presence of a stress-induced perfusion defect correlates with reversibility of that defect on resting images. Therefore, the aim of our study was to analyze, in patients without myocardial infarction, resting wall thickening and stress perfusion imaging as an alternative to conventional stress-rest imaging. METHODS AND RESULTS: The patients (n = 44) underwent an exercise (n = 37) or pharmacologic (n = 7) stress protocol. All patients had previous coronary angiography within 3 months. Stress-rest MIBI SPECT and gated MIBI SPECT studies were analyzed by visual scoring. The sensitivity and specificity of segmental analysis of both stress-rest MIBI SPECT perfusion and gated MIBI SPECT studies for the overall detection of coronary artery disease were, respectively, 71% and 96%. For patient evaluation for detection of coronary artery disease, stress-rest MIBI SPECT perfusion and gated MIBI SPECT studies showed a sensitivity rate of 96% for both and specificity rates of 84% and 79%, respectively. CONCLUSIONS: Our data revealed close agreement between reversible perfusion defects on stress-rest MIBI SPECT scans and significant wall thickening on gated MIBI SPECT stress images in patients without previous myocardial infarction (95%). Gated MIBI SPECT stress, without resting studies, which provide an assessment of wall motion and wall thickening, potentially allows stress defect reversibility to be evaluated in patients without previous myocardial infarction.  相似文献   

19.
Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT   总被引:2,自引:0,他引:2  
BACKGROUND: To determine the interpretability of gated thallium-201 perfusion SPECT compared with that performed by use of technetium-99m sestamibi (MIBI), 33 patients with prior myocardial infarction were studied. Patients received 22 to 30 mCi (814 to 1110 MBq) MIBI at peak stress, and a 15-minute gated SPECT acquisition was begun 30 to 40 minutes thereafter. On a subsequent day gated Tl-201 SPECT was acquired for 15 minutes, 4 hours after a resting 3.5 mCi (130 MBq) injection. SPECT was performed over a 180-degree arc by use of a 90-degree angled 2-detector camera. RESULTS: Gated studies were interpreted independently by 4 experienced physicians. Study quality was graded (0 = uninterpretable to 4 = excellent). Wall motion (0 = normal to 2 = akinetic/dyskinetic) and wall thickening (0 = normal to 2 = absent) were graded for each of 10 segments viewed in orthogonal planes. Left ventricular ejection fraction (LVEF) was calculated by use of software thus far validated only for MIBI. The average count density of mid-ventricular end-diastolic short axis tomograms with sestamibi was 3.47 times greater than with thallium. Mean study quality was 3.4 for MIBI and 1.8 for thallium (P < 10(-6)). No gated MIBI SPECTs, but 2 gated thallium studies (6%) were judged uninterpretable. Among interpretable scans, interobserver agreement (Kendall statistic) in assessing wall motion was 0.73 for MIBI and 0.66 for thallium (P = .01). For assessing wall thickening, the Kendall statistic was 0.73 for MIBI and 0.69 for thallium (P = .05). Correlation (r) of LVEFs was 0.91, SEE = 6.4. CONCLUSIONS: We conclude that gated thallium SPECT is inferior to MIBI because of much poorer image quality and somewhat poorer interobserver agreement among experienced physicians. However, LVEF can be determined reliably from gated thallium SPECT.  相似文献   

20.
We have developed a new, completely automatic 3-dimensional software approach to quantitative perfusion SPECT. The main features of the software are myocardial sampling based on an ellipsoid model; use of the entire count profile between the endocardial and epicardial surfaces; independence of the algorithm from myocardial shape, size, and orientation and establishment of a standard 3-dimensional point-to-point correspondence among all sampled myocardial regions; automatic generation of quantitative measurements and 5-point semiquantitative scores for each of 20 myocardial segments and automatic derivation of summed perfusion scores; and automatic generation of normal limits for any given patient population on the basis of data fractionally normalized to minimize hot spot artifacts. METHODS: The new algorithm was tested on the tomographic images of 420 patients studied with a rest 201TI (111-167 MBq, 35 s/projection)-stress 99mTc-sestamibi (925-1480 MBq, 25 s/projection) separate dual-isotope protocol on a single-detector camera, a dual-detector 90 degrees camera, and a triple-detector camera. RESULTS: The algorithm was successful in 397 of 420 patients (94.5%) and 816 of 840 image datasets (97.1%), with a statistically significant difference between the success rates of the 201TI images (399/ 420, or 95.0%) and the 99mTc images (417/420, or 99.3%; P < 0.001). Algorithm failure was caused by extracardiac uptake (10/24, or 41.7%) or inaccurate identification of the valve plane because of low count statistics (14/24, or 58.3%) and was obviated by simply limiting the image volume in which the software operates. Reproducibility of measurements of summed perfusion scores (r = 0.999 and 1 for stress and rest, respectively), global defect extent (r = 0.999 and 1 for stress and rest, respectively), and segmental perfusion scores (exact agreement = 99.9%, kappa = 0.998 for stress and 0.997 for rest) was extremely high. CONCLUSION: Automatic 3-dimensional quantitation of perfusion from 201Tl and 99mTc-sestamibi images is feasible and reproducible. The described software, because it is based on the same sampling scheme used for gated SPECT analysis, ensures intrinsically perfect registration of quantitative perfusion with quantitative regional wall motion and thickening information, if gated SPECT is used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号