1.
Purpose:
To assess the usefulness of stereotactic vacuum-assisted core breast biopsy (VCBB) performed using a stereotactic add-on device and film-screen technology with the patient in an upright seated position. Material and Methods:
We reviewed a series of 129 women with non-palpable mammographic abnormalities who required stereotactic VCBB from December 1999 to November 2000. Twenty-seven (20.9%) cases were excluded due to difficulties in keeping the correct position during the procedure, while the other 102 (79.1%) underwent successful VCBB. Patients with lesions consisting of either atypical ductal hyperplasia or lobular carcinoma in situ were considered for excisional biopsy. Patients with either ductal carcinoma in situ or infiltrating breast cancer were referred for definitive surgery. The results of stereotactic VCBB were correlated to the subsequent surgical histology. Results:
Stereotactic VCBB was interrupted because of bleeding in 1 case and vasovagal reaction in 5 cases. Two haematomas occurred after the procedure. Overall underestimation rate was 10.5%. No new lesions were discovered after a mean follow-up of 18.7 months. Conclusion:
Stereotactic VCBB performed using a standard add-on device with the patient in an upright seated position and analog technology is feasible in about 80% of cases, has a low complication rate, is not significantly time-consuming, and can offer the same accuracy as dedicated prone equipment.  相似文献   

2.
AIM: The aim of this retrospective study was to measure the accuracy of stereotactic guided 14 gauge core biopsy in distinguishing between benign and malignant causes of a mammographically detected stellate breast lesion and to assess the impact of the number of core samples taken on the sensitivity for detection of malignancy. MATERIALS AND METHODS: Seventy-two patients with mammographically detected stellate lesions of the breast formed the study group. All patients in the study group underwent multiple 14 gauge core biopsies using prone stereotactic breast biopsy equipment. The diagnostic accuracy of the technique was measured by retrospectively comparing the outcome with the core biopsy results. The result of each core sample was separately recorded to allow analysis of the effect of increasing the number of samples on accuracy. RESULTS: Nine of 72 (12%) did not have surgery. Forty of 72 (56%) had a benign surgical outcome and 23/72 (32%) a malignant surgical outcome [7/72 (10%) non-invasive, 16/72 (22%) invasive carcinoma]. The absolute sensitivity for multiple stereotactic guided core biopsies of stellate lesions for the detection of malignancy was 78% with a complete sensitivity of 100%. The sensitivity for the detection of invasive carcinoma was 94% (15 out of 16 patients). No statistically significant improvement in sensitivity was shown for multiple samples vs one sample, but in two patients, malignant tissue was only found in core samples 6-9, the first five cores showing atypia only. CONCLUSION: Multiple stereotactic guided 14 gauge core biopsies accurately distinguish malignant from benign causes of stellate breast lesions. When core biopsy histology is malignant, therapeutic surgery can be planned. When the core biopsy shows typical features of a benign radial scar, diagnostic surgical excision may not be required to confirm the diagnosis.Kirwan, S. E., (2000). Clinical Radiology55, 763-766.  相似文献   

3.
PURPOSE: To evaluate the diagnostic value of vacuum-assisted biopsy (VB) with digital stereotactic Mammotome on dubious mammary lesions clinically and sonographically negative as an alternative to surgical biopsy diagnosis. MATERIAL AND METHODS: From November 1999 to November 2000, 122 biopsies were performed using a vacuum suction aspiration device with digital stereotactic-guided Mammotome (Fischer prone table) on 116 patients between the age of 34 and 74 years (median 51 yrs). Sampling was performed with an 11 gauge probe. All patients were previously subjected to mammography in which dubious lesions were evidenced without clinical and sonogram confirmation. All lesions that were obviously benign or malignant were excluded. Mammography demonstrated isolated microcalcifications, small opacities and parenchymal distortions. Microcalcifications were then subdivided into lobular, rad-shaped, granular, mixed and pulverulent, according to Tabar's classification. The median diameter of lesions was 13 mm (range 3-50). The median number of Mammotome biopsy samples was 10.8 (range 3-19). All samples were radiographed and magnified. In 76 patients, the Mammotome biopies were incisional (only a part of the lesion was removed) and in 46 the biopsy was excisional (the entire lesion was removed). The biopsy site was marked with a non-magnetic metallic clip in 83 patients. Slight bleeding was noted during the procedure in two cases. Ultrasound visualization evidenced a hematoma at the biopsy site in one patient which was successfully resolved in one month with local therapy. No noticeable pain or patient intolerance to the procedure was observed. RESULTS: Histological probe sample examination was negative in 91 patients (74.6%) and positive in 31 patients (25.4%). The benign histologies included adenosis and epitheliosis (47 pts), sclerosing adenosis (7 pts), fibroadenoma (7 pts), fibrosis and fibrocystic mastopathy (30 pts). Of the 31 positive patients, 14 were infiltrating carcinomas (45%) and 17 ductal carcinomas in situ (DCIS) (55%). All positive cases underwent surgery. The post-surgical histological examination confirmed all diagnoses of infiltrating carcinoma while the diagnosis of DCIS was confirmed in 15 cases; infiltrating microfoci associated with DCIS were evidenced in two cases. CONCLUSIONS: VB with digital stereotactic Mammotome was shown to be a valid method for dubious mamographic lesions in which cytology often supplies an inadequate or false-negative responses. This method distinguishes between benign and malignant lesions rapidly without discomfort to the patient, thus reducing the number of diagnostic surgical biopsies. Moreover, in positive cases, it offers the advantage of avoiding extemporaneous intraoperative procedures and the possibility to perform biological tests on the tumor before surgery (estrogen and progesterone receptors, HER-2 neu, grading, Ki 67, p53 ), thus providing patient benefits and a distinct reduction of costs. However, this method is purely diagnostic and is not sufficient for therapeutical purposes.  相似文献   

4.
PURPOSE: The purpose of this study was to assess the benefits of stereotactic vacuum-assisted breast biopsy in patients with non-palpable microcalcification detected on mammography. METHODS: Between October 2001 and November 2003, stereotactic Mammotome biopsies were performed for 150 microcalcified lesions on mammography using the prone-type stereotactic vacuum-assisted breast biopsy system (Mammotest and Mammovision, Fischer, Denver, USA) . The mammography findings were classified according to the guidelines of The Japan Radiological Society/The Japan Association of Radiological Technologists. Ninety-eight cases were category 3, 38 were category 4, and 14 were category 5. RESULTS: All cases were determined to be cases of microcalcification by specimen radiography or histology. Complications were negligible. One hundred twenty of the cases were mastopathy, and 30 of them were breast cancer (14 were ductal carcinoma in situ, 7 were ductal carcinoma in situ with microinvasion, and 9 were invasive ductal carcinoma). Twenty-seven breast cancers were diagnosed as category 4 or 5 (51.9%) on mammography. The operative stages of 27 cases were as follows: 7 were stage 0, 17 were stage 1, and 3 were stage 2A. Twenty-four of 27 (88.9%) were early breast cancers. CONCLUSION: Mammotome biopsy is a safe and useful modality for the histological diagnosis of non-palpable microcalcifications.  相似文献   

5.
Stereotactic breast biopsy: recumbent biopsy using add-on upright equipment   总被引:2,自引:0,他引:2  
OBJECTIVE: The purpose of the study was to show that stereotactic breast biopsy can be performed effectively and accurately using add-on stereotactic equipment when it is performed with the patient in a decubitus or recumbent position. MATERIALS AND METHODS: We retrospectively reviewed the results of 225 stereotactic core breast biopsies performed during a 42-month period. The biopsies were performed using a reclining mammography chair and add-on stereotactic equipment. Procedures were performed with the patient in the right or left lateral decubitus position or upright. Patients with benign biopsy results were followed up mammographically at 6 months initially, then yearly. RESULTS: Of the 225 lesions biopsied stereotactically, 205 lesions (91%) were biopsied with the patient in the decubitus (right or left) position and 20 (9%) biopsied with the patient upright. Pathology results were classified as abnormal in 45 lesions (20%) and normal in 180 lesions (80%). All but one of the abnormal lesions were followed up with surgical excision. One hundred thirty-four of the 180 benign lesions have been followed up with at least one 6-month mammogram (follow-up range, 6-40 months), and none of the lesions has been subsequently proven malignant. CONCLUSION: Stereotactic core biopsy can be performed effectively and accurately using standard add-on equipment when it is performed with the patient in the decubitus position. This approach obviates the use of dedicated prone stereotactic equipment.  相似文献   

6.
OBJECTIVE: The purpose of this prospective study was to assess the accuracy of an add-on stereotactic unit for core needle biopsy of mammographic lesions. SUBJECTS AND METHODS. Between September 1994 and February 2001, 506 stereotactic core needle biopsies of mammographic lesions in 492 patients were performed in our center on a mammography unit with add-on stereotactic equipment. Of the initial 92 patients, 80 underwent stereotactic core needle biopsy and surgical excision simultaneously. In subsequent cases, surgical biopsy was performed after core biopsy in patients who had malignant or atypical histologic results or discordance between mammographic and pathologic findings. Follow-up mammography was advised for all patients whose core biopsy results were diagnosed as benign lesions. RESULTS: Histologic results for 506 lesions undergoing stereotactic core needle biopsy were as follows: 113 (22.3%) were malignant; 369 (72.9%), benign; and 24 (4.7%), atypical. Of 113 malignant lesions identified at stereotactic core needle biopsy, 111 were confirmed as malignant, whereas two showed no evidence of malignancy at surgical excision. Of 369 lesions diagnosed as benign at stereotactic core needle biopsy, 172 (46.6%) showed no change on follow-up mammography, 114 (30.9%) were lost to follow-up, and 83 (22%) underwent surgical excision. Of 24 lesions with atypical histology, 23 had surgical follow-up, six were malignant, nine were benign, and eight were confirmed as showing atypical histology. Stereotactic core needle biopsy of the 506 lesions was complicated by five (1.0%) cases of vasovagal attack and four (0.8%) cases of bleeding. The resulting sensitivity, specificity, and positive and negative predictive values were 98.3%, 93.0%, 86.0%, and 99.2% respectively. CONCLUSION: Biopsy with an add-on unit is safe, reliable, accurate, and cost-effective with results comparable to those reported for dedicated prone biopsy devices.  相似文献   

7.
目的:探讨全数字化X线立体定位及活体组织检查对临床不可触及乳腺病变(NPBL)的诊断及应用价值。方法95例临床触诊阴性乳腺数字钼靶摄片发现微小病变。乳腺影像报告和数据系统(BI-RADS)分级4或4以上。27例行立体定位穿刺活检(SCNB);68例行立体定位下导丝引导活检(SNLB)。结果27例SCNB,25例病理结果一致,2例病理结果低估,活检符合率92%。68例SNLB均定位成功,病变完全切除,符合率100%。结论 SCNB使乳腺良性病变切取数目降到最低,创伤小、费用低,诊断准确率高。SNLB获得的病理诊断准确、可靠。两者相比较SNLB弥补了SCNB的取材不足及假阴性,能够获得可靠的病理结果,一次同时完成诊断和治疗。  相似文献   

8.

Purpose

The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4.

Materials and methods

From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure.

Results

A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years.

Conclusions

VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.  相似文献   

9.
The objective of this study was to assess the usefulness of stereotactic large-core needle biopsy (LCNB) in the management of nonpalpable breast lesions (NBL) and compare it with stereotactic fine-needle aspiration biopsy (SFNA) performed simultaneously in a significant number of cases. From November 1993 through June 1997, 510 consecutive patients with NBL underwent 14-gauge LCNB with 354 women undergoing simultaneous 21-gauge SFNA in the same lesion. Mammographic findings, lesion size, number of core biopsy specimens, complications and diagnoses of both techniques were analysed. Surgical biopsy, tumorectomy or mastectomy was indicated for malignancy or poor correlation between SFNA or LCNB results and clinical or radiological findings. Values of diagnostic accuracy of both LCNB and SFNA were determined. The ratio benign surgical biopsies/malignant surgical biopsies (BB/CB) of the series was calculated. A total of 171 patients underwent surgical treatment; in 31 (18.1 %) a benign process or atypical ductal hyperplasia was the final diagnosis. The ratio BB/CB was 0.22. Sensitivity and specificity were 93.2 and 100 %, respectively, for LCNB, and 77.2 and 92.3 %, respectively, for SFNA with cytological analysis. Large-core needle biopsy provides more accurate diagnosis than SFNA in the management of nonpalpable breast lesions and obviates a surgical diagnostic procedure in a significant number of cases. Received 17 November 1997; Revision received 4 February 1998; Accepted 16 March 1998  相似文献   

10.
AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS.  相似文献   

11.

Purpose

This study was undertaken to compare the cost effectiveness of two vacuum-assisted breast biopsy devices, the Mammotome and Vacora systems.

Materials and methods

Between January and June 2006, 238 vacuum-assisted breast biopsies were performed at our radiology department. Five out of 238 lesions were excluded because of inadequate sampling. The Mammotome system was used in 108/233 lesions and the Vacora system in 125/233. Fifty-eight lesions underwent ultrasound-guided breast biopsy, and 50 lesions underwent mammography-guided biopsy with both Mammotome and Vacora devices. Magnetic-resonance-guided biopsy was possible with the Vacora system only (17/125 lesions).

Results

All procedures were successfully completed. No significant differences were found between the results of the Mammotome and Vacora biopsies in terms of effectiveness: sensitivity was 84.4% and 86.2%, respectively, and specificity 100%. In terms of cost, the Mammotome system has higher costs per procedure compared with the Vacora.

Conclusions

Our clinical results confirm the diagnostic accuracy of both the Mammotome and Vacora systems, whereas our cost analysis shows that there is a considerable difference, mostly related to the initial investment.  相似文献   

12.
PURPOSE: The purpose of this study was to assess the accuracy and clinical usefulness of stereotactic vacuum-assisted biopsy (VAB) for diagnosing suspicious, nonpalpable, only mammographically detectable breast lesions. MATERIALS AND METHODS: We retrospectively evaluated the results of percutaneous stereotactic VAB with 11-gauge needles performed over a period of 34 months on 228 nonpalpable suspicious breast lesions detectable on mammography only [Breast Imaging Reporting and Data System (BI-RADS) 3: 25.9%; BI-RADS 4: 67.1%; BI-RADS 5: 7%]. The imaging histological concordance was ascertained for each lesion. In cases of discordance, repeat biopsy or surgical excision were recommended; in cases of benign lesions, we urged a follow-up of at least 6 months and for borderline and malignant lesions a surgical excision. We also evaluated concordance between VAB results and subsequent examinations (surgical excision or followup). RESULTS: VAB demonstrated 123 (54%) benign lesions (with six cases of imaging-histological discordance), 26 (11.4%) borderline lesions and 79 (34.6%) malignant lesions. We obtained a suitable post-VAB mammographic or histological evaluation for 78 benign lesions, 17 borderline lesions and 76 malignant lesions, with one (1.3%) false negative (FN) case, two (11.8%) underestimations of borderline lesions, 14 (18.4%) underestimations of malignant lesions and no (0%) false positive cases. We did not observe any postbiopsy complications or scars. CONCLUSIONS: Percutaneous histological VAB with an 11-gauge needle proved to be, as reported in previous studies, a reliable method for diagnosing nonpalpable, mammographically detectable only breast lesions, with an underestimation rate lower than core biopsy and a FN rate similar to that of surgical biopsy, without any significant complications.  相似文献   

13.
PURPOSE: To compare the preoperative results of stereotactic fine needle aspiration biopsy (S-FNAB) with stereotactic core needle biopsy (S-CNB) performed simultaneously in breast lesions with the postoperative histopathological diagnosis of ductal carcinoma in situ (DCIS) of all histological grades. MATERIAL AND METHODS: 733 consecutive stereotactic biopsies were performed between May 1993 and June 1999. In 72 patients with mammographic findings suspicious of malignancy who were subjected to breast surgery, postoperative histopathology showed DCIS. Preoperatively, S-FNAB and S-CNB had been done simultaneously in all patients, S-FNAB with spinal needle 0.7 or 0.9 mm and S-CNB was performed with an automated 2.1-mm biopsy gun. An average of 3 S-FNABs and 3 S-CNBs were performed in each patient. RESULTS: In 56 (78%) of the 72 patients S-CNB showed DCIS. In 3 patients (4%) the S-CNB revealed "probable carcinoma", in 7 patients (10%) "atypia" and in 6, the lesions were benign. In 34 (47%) of the 72 women S-FNABs showed carcinoma, not otherwise specified. In 6 cases (8%) the S-FNABs showed "probable carcinoma" and in 12 patients (17%) "atypia"; 8 lesions were benign and 12 not diagnostic. CONCLUSION: S-CNB was superior to S-FNAB in diagnosing DCIS. Only 6 patients (8%) received a benign or non-diagnostic preoperative diagnosis with S-CNB compared to 20 patients (28%) with S-FNAB. S-CNB was superior to S-FNAB for preoperative diagnosis of DCIS, but S-FNAB could further increase the sensitivity of the biopsy since it diagnosed cancer in 4 cases where S-CNB showed benign material.  相似文献   

14.
目的探讨全数字化乳腺摄影及X线立体定位系统在乳腺导管内癌(DCIS)中的临床应用价值。资料与方法经手术、病理证实的DCIS 24例。全部病例经全数字化乳腺摄影检查,其中21例表现为微钙化,应用俯卧式X线立体定位系统行病灶术前穿刺活检、切除。结果 24例中,X线表现为微钙化21例,其中单纯钙化18例,钙化伴局灶性非对称性致密2例,钙化伴局部结构扭曲1例;1例X线表现为边缘呈星芒状的小肿块;1例乳腺X线摄影仅见乳晕区皮肤增厚;X线表现阴性1例。结论全数字化乳腺摄影使乳腺细微结构的显示率及分辨率得到大幅度的提高,越来越多乳腺微钙化病灶被发现,术前结合X线立体定位术活检能发现更多DCIS,使其得以早期治疗,为提高乳腺癌治愈率和广泛开展保乳手术、提高患者的生活质量奠定基础。  相似文献   

15.
目的:探讨及总结超声引导在麦默通微创旋切系统治疗乳腺良性肿瘤中的应用效果及经验。方法对635例,1089个乳腺病灶均使用超声引导下麦默通微创旋切系统切除病灶,并评价其效果。结果635例病例中,乳腺增生症228例,乳腺纤维瘤233例,乳腺囊肿138例,导管内乳头状瘤32例,乳腺恶性肿瘤4例,术后出现并发症81例。结论运用超声的引导进行乳腺良性肿块麦默通微创切除术,具有实时、安全、高效、准确等优点,是一种值得临床推广及应用的手术方法。  相似文献   

16.
OBJECTIVE: Breast calcifications pose a significant diagnostic and procedural dilemma. We evaluated en bloc stereotactic excision of indeterminate and suggestive microcalcifications for histologic diagnosis using a large-bore cannula biopsy device. MATERIALS AND METHODS: We retrospectively reviewed 61 groups of microcalcifications removed with a large-bore cannula biopsy device from 59 patients (age range, 35-72 years old). The cannula diameter was 20 mm in 47 cases, 15 mm in nine cases, and 10 mm in five cases. The median lesion diameter was 6.6 mm (range, 4-17 mm). The procedure was performed by radiologists in an outpatient setting, with patients undergoing local anesthesia. All patients with a diagnosis of malignancy underwent surgery. RESULTS: In all instances, microcalcifications were removed in a single pass, in a single intact tissue specimen, through a maximum skin incision of 2 cm (0.8 inch). Twenty-five malignancies, 34 benign lesions, and two cases of lobular carcinoma in situ were identified. Sixteen malignancies were noninvasive and nine were invasive. No residual tumor was found at surgery in six of the 18 cases with involved margins and in five of the seven cases with uninvolved margins. One case of lobular carcinoma in situ with involvement of the margins additionally showed ductal carcinoma in situ at surgery. CONCLUSION: Mammographically identified microcalcifications are excised en bloc with the large-bore cannula biopsy device, providing a stereotactically localized tissue sample that is comparable with that obtained with open surgical biopsy and allows evaluation of the margins. This surgical radiologic procedure may represent a valid alternative, in selected patients, to conventional surgical biopsy after radiologic localization.  相似文献   

17.
PURPOSE: To compare pathologic findings from stereotactic core and excisional biopsies in patients with microcalcifications in the breast. MATERIAL AND METHODS: Stereotactic core needle biopsies of 101 lesions with mammographic evidence of microcalcifications were performed with long-throw (2.2 cm) automated core biopsy devices fitted with 2.1-mm needles. The core specimens were placed on microscope slides and radiographed. The pathologic features of core and excisional specimens were compared. RESULTS: In 100 of the 101 breast lesions, a correct choice for an additional diagnostic procedure or definitive treatment could have been made upon histopathologic findings of the core needle biopsy. CONCLUSION: Stereotactic core needle biopsy is a reliable alternative to surgical biopsy of breast lesions with microcalcifications provided that specimen radiography has been performed to ensure that appropriate tissue has been obtained. Excisional biopsy may be avoided if microcalcifications are visible in radiographs of core biopsy specimen with benign histology.  相似文献   

18.
OBJECTIVE: The purpose of this study was to compare the usefulness of, and cost of diagnosing with, different breast biopsy methods for women with calcifications highly suggestive of malignancy. MATERIALS AND METHODS: One hundred thirty-nine women with calcifications highly suggestive of malignancy underwent diagnostic biopsy. Of these, 89 women had stereotactic biopsy with a 14-gauge automated needle (n = 25), 14-gauge vacuum-assisted probe (n = 17), or 11-gauge vacuum-assisted probe (n = 47); and 50 women had diagnostic surgical biopsy. Medical records were reviewed. Cost savings for stereotactic biopsy were calculated using Medicare data. RESULTS: The median number of operations was one for women who had stereotactic biopsy versus two for women who had diagnostic surgical biopsy. The likelihood of undergoing a single operation was significantly greater for women who had stereotactic rather than surgical biopsy, among all women (61/89 [68.5%] vs. 19/50 [38.0%], p < 0.001) and among women treated for breast cancer (55/77 [71.4%] vs. 6/37 [16.2%], p = 0.0000001). Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, was significantly more likely to spare a surgical procedure (36/47 [76.6%] vs. 16/42 [38.1%], p = 0.0005). Stereotactic 11-gauge vacuum-assisted biopsy resulted in the greatest cost reduction, yielding savings of $315 per case compared with diagnostic surgical biopsy; for women with solitary lesions, stereotactic 11-gauge biopsy decreased the cost of diagnosis by 22.2% ($334/$1502). CONCLUSION: For women with calcifications highly suggestive of malignancy, the use of stereotactic rather than surgical biopsy decreases the number of operations. Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, is significantly more likely to spare a surgical procedure and has the highest cost savings.  相似文献   

19.
立体定位穿刺留置导丝引导手术活检隐匿性乳腺病灶   总被引:1,自引:2,他引:1  
目的 评价立体定位穿刺留置导丝引导手术活检术对临床触诊阴性而乳腺X线摄影发现的隐匿性乳腺病变定位活检的价值。材料与方法 临床扪诊阴性 ,而乳腺X线片显示成簇的细小钙化、模糊小结节及局部结构紊乱等可疑的恶性病灶 ,通过计算机立体定位下穿刺 ,留置导丝于可疑的病灶区 ,然后手术取活体组织行病理学检查。结果  31例患者 ,乳腺X线检查发现病灶34个 ,定位穿刺留置导丝 32根 ,导丝引导下手术活检 32例次均一次性成功定位与切除 ,定性诊断正确率为 10 0 %。病理检查结果 :恶性病变 9例次 11个病灶 ,良性病变 2 3例次。恶性病变中浸润性导管癌 4例次 5个病灶 ,导管内癌 3例次 ,乳腺单纯癌 2例次 3个病灶。结论 立体定位穿刺留置导丝引导手术活检术对乳腺隐匿性病变定位活检准确 ,既解决了外科医生术中对乳腺微小的病变定位的困难 ,又解决了盲目手术切除或针穿活检假阴性的问题。此技术创伤小 ,简单易行 ,是目前诊断早期乳腺癌的有效方法和技术保证  相似文献   

20.
To prospectively evaluate a compact portable 10-gauge handheld battery-operated biopsy system for stereotactic biopsy of microcalcifications. The ethics committee of the hospital approved this prospective multicentric study, and informed consent was obtained. Biopsy under stereotactic guidance was performed in 215 patients for 219 lesions consisting of microcalcifications without mass. The feasibility and the tolerance of the procedure were evaluated. The mean weight of the specimen was calculated. In patients with surgical diagnoses, the underestimation rate in biopsy diagnoses of atypical ductal hyperplasia and ductal carcinoma in situ were evaluated. The sampled specimens were separated according to the presence of calcifications on magnified specimen radiographs and to the probe the rotation number in order to evaluate the contribution of each rotation and the contribution of the specimen with and without calcifications on the radiographs. The macrobiopsy was feasible in 98.5% of the patients and was well tolerated in 82% of patients. It identified 4.6% invasive carcinomas, 18.5% ductal carcinomas in situ, 14.8% atypical ductal hyperplasias, 22.2% benign proliferative mastopathies and 39.8% benign non-proliferative mastopathies. The underestimation rate was 26.6% when an atypical ductal hyperplasia was diagnosed at biopsy, and 7.7% when a ductal carcinoma in situ was diagnosed. In the 77 patients with surgical correlation, the accurate diagnosis was obtained in specimens sampled during the first, second, and third in 69%, 9%, and 4% of the biopsies, respectively, and the analysis of specimens without microcalcification had an added value in 8% of patients. The compact portable battery-operated biopsy system can be used successfully for stereotactic biopsy of microcalcifications and constitutes a valid alternative to current systems.  相似文献   