1.
This study investigates the feasibility of using Monte Carlo methods to assist the commissioning of photon beam output factors from a medical accelerator. The Monte Carlo code, BEAMnrc, was used to model 6 MV and 18 MV photon beams from a Varian linear accelerator. When excellent agreements were obtained between the Monte Carlo simulated and measured dose distributions in a water phantom, the entire geometry including the accelerator head and the water phantom was simulated to calculate the relative output factors. Simulated output factors were compared with measured data, which consist of a typical commission dataset for the output factors. The measurements were done using an ionization chamber in a water phantom at a depth of 10 cm with a source-detector distance of 100 cm. Square fields and rectangular fields with widths and lengths ranging from 4 cm to 40 cm were studied. The result shows a very good agreement (< 1.5%) between the Monte Carlo calculated and the measured relative output factors for a typical commissioning dataset. The Monte Carlo calculated backscatter factors to the beam monitor chamber agree well with measured data in the literature. Monte Carlo simulations have also been shown to be able to accurately predict the collimator exchange effect and its component for rectangular fields. The information obtained is also useful to develop an algorithm for accurate beam modelling. This investigation indicates that Monte Carlo methods can be used to assist commissioning of output factors for photon beams.  相似文献   

2.
The purpose of this study was to investigate the feasibility of using Monte Carlo methods to assist in the commissioning of electron beams for a medical linear accelerator. The EGS4/BEAM code system was used to model an installed linear accelerator at this institution. Following an initial tuning of the input parameters, dosimetry data normally measured during the machine commissioning was calculated using the Monte Carlo code. All commissioning data was calculated for 6- and 12-MeV electron beams, and a subset of the commissioning data was calculated for the 20-MeV electron beams. On central axis, calculated percentage depth dose, cross-beam profiles, cone-insert ratios, and air-gap factors were generally within 2% of Dmax or 1 mm of the measured commissioning data; however, calculated open-cone ratios were not within 2%, in most cases. Calculated off-axis dose profiles for small fields were generally within the 2% (1-mm) criteria; however, calculated dose profiles for larger (open cone) fields frequently failed the 2% (1-mm) criteria. The remaining discrepancies between Monte Carlo calculations and measurement could be due to flaws in the Monte Carlo code, inaccuracies in the simulation geometry, the approximation of the initial source configuration, or a combination of the above. Although agreement between Monte Carlo calculated and measured doses was impressive and similar to previously published comparisons, our results did not prove our hypothesis that Monte Carlo calculations can generate electron commissioning data that is accurate within 2% of Dmax or 0.1 cm over the entire range of clinical treatment parameters. Although we believe that this hypothesis can be proved, it remains a challenge for the medical physics community. We intend to pursue this further by developing systematic methods for isolating causes of these differences.  相似文献   

3.
Clinical implementation of a Monte Carlo treatment planning system.   总被引:4,自引:0,他引:4  
The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used to reconstruct the phase-space data for both electron and photon beams, which retained the accuracy of the Monte Carlo beam data. The multiple-source model reduced the phase-space data storage requirement by a factor of 1000 and the accelerator simulation time by a factor of 10 or more. Agreement within 2% was achieved between the Monte Carlo calculations and measurements of the dose distributions in homogeneous and heterogeneous phantoms for various field sizes, source-surface distances, and beam modulations. The Monte Carlo calculated electron output factors were within 2% of the measured values for various treatment fields while the heterogeneity correction factors for various lung and bone phantoms were within 1% for photon beams and within 2% for electron beams. The EGS4/DOSXYZ Monte Carlo code was used for phantom and patient dose calculations. The results were compared to the dose distributions produced by a conventional treatment planning system and an intensity-modulated radiotherapy inverse-planning system. Significant differences (>5% in dose and >5 mm shift in isodose lines) were found between Monte Carlo calculations and the analytical calculations implemented in the commercial systems. Treatment sites showing the largest dose differences were for head and neck, lung, and breast cases.  相似文献   

4.
The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the dimensions of the field size at the isocentre. The energy spectra of the contaminant electrons are predetermined using Monte Carlo simulations for photon beams from different clinical accelerators. A 'random creep' method is employed to derive the weight of the electron contamination source by matching Monte Carlo calculated monoenergetic photon and electron percent depth-dose (PDD) curves with measured PDD curves. We have integrated this electron contamination source into a previously developed multiple source model and validated the model for photon beams from Siemens PRIMUS accelerators. The EGS4 based Monte Carlo user code BEAM and MCSIM were used for linac head sinulation and dose calculation. The Monte Carlo calculated dose distributions were compared with measured data. Our results showed good agreement (less than 2% or 2 mm) for 6, 10 and 18 MV photon beams.  相似文献   

5.
A simple analytical approach has been developed to model extrafocal radiation and monitor chamber backscatter for clinical photon beams. Model parameters for both the extrafocal source and monitor chamber backscatter are determined simultaneously using conventional measured data, i.e., in-air output factors for square and rectangular fields defined by the photon jaws. The model has been applied to 6 MV and 15 MV photon beams produced by a Varian Clinac 2300C/D accelerator. Contributions to the in-air output factor from the extrafocal radiation and monitor chamber backscatter, as predicted by the model, are in good agreement with the measurements. The model can be used to calculate the in-air output factors analytically, with an accuracy of 0.2% for symmetric or asymmetric rectangular fields defined by jaws when the calculation point is at the isocenter and 0.5% when the calculation point is at an extended SSD. For MLC-defined fields, with the jaws at the recommended positions, calculated in-air output factors agree with the measured data to within 0.3% at the isocenter and 0.7% at off-axis positions. The model has been incorporated into a Monte Carlo dose algorithm to calculate the absolute dose distributions in patients or phantoms. For three MLC-defined irregular fields (triangle shape, C-shape, and L-shape), the calculations agree with the measurements to about 1% even for points at off-axis positions. The model will be particularly useful for IMRT dose calculations because it accurately predicts beam output and penumbra dose.  相似文献   

6.
Chow JC 《Medical physics》2007,34(1):175-182
Monte Carlo simulation was used to calculate the lateral buildup ratio (LBR) used in estimating the percentage depth dose (PDD) and dose per monitor unit for an irregular shaped cutout field in electron radiotherapy. Monte Carlo code BEAMnrc/EGSnrc was used to build a simulation model for a Varian 21 EX linear accelerator producing clinical electron beams with energies of 4, 6, 9, 12, and 16 MeV. The model is optimized by adjusting the incident electron energy within the Monte Carlo simulation so that the calculated PDD curves agree with the measurement within +/-2%. The LBR is calculated from the PDD curves for different diameters of circular cutouts. Although Monte Carlo simulation requires a longer time to create a LBR database compared to measurement using scanning water tank and dosimeter, the simulation models for different electron energies, applicators, and cutouts are very similar. As the calculations can be carried out in a batch mode automatically run by a computer, human efforts in carrying out measurements in the treatment room and fabricating the circular cutouts in the mold room are greatly saved. Moreover, the simulation avoids human error in the experimental setup and can better handle the electron scattering affecting accuracy in the measurement. Using Monte Carlo simulation to calculate the LBR is proved to be useful in the commissioning of the electron beams for electron radiotherapy.  相似文献   

7.
Extensive work has been performed to validate Monte Carlo models for both photon and electron beams under standard conditions. However, for large field electron beam therapy, Monte Carlo simulations have not been able to provide good agreement when compared to the measured dose distributions. Since the accuracy of the calculation relies heavily on the geometry parameters of the linear accelerator and the characteristics of the incident electron beam, it is crucial to have a complete comprehension of these independent factors. In this work, the electron focal spot size for a CL21EX linac with various energies (6, 9, 12 and 16 MeV) was measured with a slit camera composed of alternating lead and paper sheets. For all the energies investigated, the electron focal spot is found to be elliptical and has a full width at half maximum (FWHM) ranging from 1.69 mm to 2.24 mm. A shift with respect to the crosshair was associated with each measured focal spot. In addition, we present an improved result for the large field in-air profile by utilizing a proposed divergent beam model in conjunction with the experimental focal spot dimension. This model can potentially provide a solution to the Monte Carlo validation of large field electron beam therapy.  相似文献   

8.
Jiang SB  Kapur A  Ma CM 《Medical physics》2000,27(1):180-191
A hybrid approach for commissioning electron beam Monte Carlo treatment planning systems has been studied. The approach is based on the assumption that accelerators of the same type have very similar electron beam characteristics and the major difference comes from the on-site tuning of the electron incident energy at the exit window. For one type of accelerator, a reference machine can be selected and simulated with the Monte Carlo method. A multiple source model can be built on the full Monte Carlo simulation of the reference beam. When commissioning electron beams from other accelerators of the same type, the energy spectra in the source model are tuned to match the measured dose distributions. A Varian Clinac 2100C accelerator was chosen as the reference machine and a four-source beam model was established based on the Monte Carlo simulations. This simplified beam model can be used to generate Monte Carlo dose distributions accurately (within 2%/2 mm compared to those calculated with full phase space data) for electron beams from the reference machine with various nominal energies, applicator sizes, and SSDs. Three electron beams were commissioned by adjusting the energy spectra in the source model. The dose distributions calculated with the adjusted source model were compared with the dose distributions calculated using the phase space data for these beams. The agreement is within 1% in most of cases and 2% in all situations. This preliminary study has shown the capability of the commissioning approach for handling large variation in the electron incident energy. The possibility of making the approach more versatile is also discussed.  相似文献   

9.
Electron beam treatments may benefit from techniques to verify patient positioning and dose delivery. This is particularly so for complex techniques such as mixed photon and electron beam radiotherapy and electron beam modulated therapy. This study demonstrates that it is possible to use the bremsstrahlung photons in an electron beam from a dual scattering foil linear accelerator to obtain portal images of electron beam treatments. The possibility of using Monte Carlo (MC) simulations to predict the electron beam treatment portal images was explored. The MC code EGSnrc was used to model a Varian CL21EX linear accelerator (linac) and to characterize the bremsstrahlung photon production in the linac head. It was found that the main sources of photons in the electron beam are the scattering foils, the applicator and the beam-shaping cut-out. Images were acquired using the Varian CL21EX linac and the Varian aS500 electronic portal imager (EPI); four electron energies (6, 9, 12, 16 MeV), and different applicator and cut-out sizes were used. It was possible to acquire images with as little as 10.7 MU per image. The contrast, the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), the resolution and an estimate of the modulated transfer function (MTF) of the electron beam portal images were computed using a quality assurance (QA) phantom and were found to be comparable to those of a 6 MV photon beam. Images were also acquired using a Rando anthropomorphic phantom. MC simulations were used to model the aS500 EPID and to obtain predicted portal images of the QA and Rando phantom. The contrast in simulated and measured portal images agrees within +/-5% for both the QA and the Rando phantom. The measured and simulated images allow for a verification of the phantom positioning by making sure that the structure edges are well aligned. This study suggests that the Varian aS500 portal imager can be used to obtain patient portal images of electron beams in the scattering foil linacs.  相似文献   

10.
In some linear accelerators, the charge collected by the monitor ion chamber is partly caused by backscattered particles from accelerator components downstream from the chamber. This influences the output of the accelerator and also has to be taken into account when output factors are derived from Monte Carlo simulations. In this work, the contribution of backscattered particles to the monitor ion chamber response of a Varian 2100C linac was determined for photon beams (6, 10 MV) and for electron beams (6, 12, 20 MeV). The experimental procedure consisted of charge integration from the target in a photon beam or from the monitor ion chamber in electron beams. The Monte Carlo code EGS4/BEAM was used to study the contribution of backscattered particles to the dose deposited in the monitor ion chamber. Both measurements and simulations showed a linear increase in backscatter fraction with decreasing field size for photon and electron beams. For 6 MV and 10 MV photon beams, a 2-3% increase in backscatter was obtained for a 0.5 x 0.5 cm2 field compared to a 40 x 40 cm2 field. The results for the 6 MV beam were slightly higher than for the 10 MV beam. For electron beams (6, 12, 20 MeV), an increase of similar magnitude was obtained from measurements and simulations for 6 MeV electrons. For higher energy electron beams a smaller increase in backscatter fraction was found. The problem is of less importance for electron beams since large variations of field size for a single electron energy usually do not occur.  相似文献   

11.
The aim of this study was to investigate the dosimetric characteristics of the electron beams generated by the light intraoperative accelerator, Liac? (SORDINA, Italy), using Monte Carlo (MC) calculations. Moreover we investigated the possibility of characterizing the Liac? dosimetry with a minimal set of dosimetric data. In fact accelerator commissioning requires measurements of both percentage depth doses (PDDs) and off-axis profiles for all the possible combinations of energy, applicator diameter and bevelled angle. The Liac? geometry and water phantom were simulated in a typical measurement setup, using the MC code EGSnrc/BEAMnrc. A simulated annealing optimization algorithm was used in order to find the optimal non-monoenergetic spectrum of the initial electron beam that minimizes the differences between calculated and measured PDDs. We have concluded that, for each investigated nominal energy beam, only the PDDs of applicators with diameters of 30, 70 and 100 mm and the PDD without an applicator were needed to find the optimal spectra. Finally, the output factors of the entire set of applicator diameters/bevelled angles were calculated. The differences between calculated and experimental output factors were better than 2%, with the exception of the smallest applicator which gave differences between 3% and 4% for all energies. The code turned out to be useful for checking the experimental data from various Liac? beams and will be the basis for developing a tool based on MC simulation to support the medical physicist in the commissioning phase.  相似文献   

12.
Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 x 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 x 10(13) +/- 1.0% electrons incident on the target and a total dose of 20.87 cGy +/- 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.  相似文献   

13.
Megavoltage portal images suffer from poor quality compared to those produced with kilovoltage x-rays. Several authors have shown that the image quality can be improved by modifying the linear accelerator to generate more low-energy photons. This work addresses the problem of using Monte Carlo simulation and experiment to optimize the beam and detector combination to maximize image quality for a given patient thickness. A simple model of the whole imaging chain was developed for investigation of the effect of the target parameters on the quality of the image. The optimum targets (6 mm thick aluminium and 1.6 mm copper) were installed in an Elekta SL25 accelerator. The first beam will be referred to as A16 and the second as Cu1.6. A tissue-equivalent contrast phantom was imaged with the 6 MV standard photon beam and the experimental beams with standard radiotherapy and mammography film/screen systems. The arrangement with a thin Al target/mammography system improved the contrast from 1.4 cm bone in 5 cm water to 19% compared with 2% for the standard arrangement of a thick, high-Z target/radiotherapy verification system. The linac/phantom/detector system was simulated with the BEAM/EGS4 Monte Carlo code. Contrast calculated from the predicted images was in good agreement with the experiment (to within 2.5%). The use of MC techniques to predict images accurately, taking into account the whole imaging system, is a powerful new method for portal imaging system design optimization.  相似文献   

14.
Stereotactic radiosurgery with several static conformal beams shaped by a micro multileaf collimator (microMLC) is used to treat small irregularly shaped brain lesions. Our goal is to perform Monte Carlo calculations of dose distributions for certain treatment plans as a verification tool. A dedicated microMLC component module for the BEAMnrc code was developed as part of this project and was incorporated in a model of the Varian CL2300 linear accelerator 6 MV photon beam. As an initial validation of the code, the leaf geometry was visualized by tracing particles through the component module and recording their position each time a leaf boundary was crossed. The leaf dimensions were measured and the leaf material density and interleaf air gap were chosen to match the simulated leaf leakage profiles with film measurements in a solid water phantom. A comparison between Monte Carlo calculations and measurements (diode, radiographic film) was performed for square and irregularly shaped fields incident on flat and homogeneous water phantoms. Results show that Monte Carlo calculations agree with measured dose distributions to within 2% and/or 1 mm except for field size smaller than 1.2 cm diameter where agreement is within 5% due to uncertainties in measured output factors.  相似文献   

15.
A dedicated, efficient Monte Carlo (MC) accelerator head model for intensity modulated stereotactic radiosurgery treatment planning is needed to afford a highly accurate simulation of tiny IMRT fields. A virtual source model (VSM) of a mini multi-leaf collimator (MLC) (the Elekta Beam Modulator (EBM)) is presented, allowing efficient generation of particles even for small fields. The VSM of the EBM is based on a previously published virtual photon energy fluence model (VEF) (Fippel et al 2003 Med. Phys. 30 301) commissioned with large field measurements in air and in water. The original commissioning procedure of the VEF, based on large field measurements only, leads to inaccuracies for small fields. In order to improve the VSM, it was necessary to change the VEF model by developing (1) a method to determine the primary photon source diameter, relevant for output factor calculations, (2) a model of the influence of the flattening filter on the secondary photon spectrum and (3) a more realistic primary photon spectrum. The VSM model is used to generate the source phase space data above the mini-MLC. Later the particles are transmitted through the mini-MLC by a passive filter function which significantly speeds up the time of generation of the phase space data after the mini-MLC, used for calculation of the dose distribution in the patient. The improved VSM model was commissioned for 6 and 15 MV beams. The results of MC simulation are in very good agreement with measurements. Less than 2% of local difference between the MC simulation and the diamond detector measurement of the output factors in water was achieved. The X, Y and Z profiles measured in water with an ion chamber (V = 0.125 cm(3)) and a diamond detector were used to validate the models. An overall agreement of 2%/2 mm for high dose regions and 3%/2 mm in low dose regions between measurement and MC simulation for field sizes from 0.8 x 0.8 cm(2) to 16 x 21 cm(2) was achieved. An IMRT plan film verification was performed for two cases: 6 MV head&neck and 15 MV prostate. The simulation is in agreement with film measurements within 2%/2 mm in the high dose regions (> or = 0.1 Gy = 5% D(max)) and 5%/2 mm in low dose regions (<0.1 Gy).  相似文献   

16.
Percentage depth dose (PDD) distributions and beam profiles of very small diameter (1.5-5 mm) megavoltage radiosurgical beams calculated with Monte Carlo (MC) technique critically depend on the diameter of the circular focal spot used in the simulation: The smaller is the field diameter, the larger is the effect. Thus, in simulations of radiosurgical fields that have diameters of the order of the focal spot size, an accurate focal spot geometry should be used. We used a simplified moving slit technique in conjunction with a diode detector for evaluation of the focal spot size and shape of a megavoltage 6 MV linac as well as for determination of the equivalent focal spot diameter of the linac for use in MC simulations. The measured total diode signal contains three components: A direct focal spot signal, a background signal, and an extra-focal radiation signal. A single profile scan of the focal spot signal is Gaussian like in shape, and its full width at half maximum is used to define the focal spot dimension for this scan. The focal spot of our 6 MV linac is approximated with a Gaussian circle, and when the geometry of the effective focal spot circle is used in MC simulations, the agreement between MC-calculated and measured PDD distributions as well as beam profiles is good even for radiosurgical fields as small as 1.5 mm in diameter. Our results also confirm that matching the penumbral areas of accurately measured large-field beam profiles to the same areas of the MC-calculated beam profiles reliably leads to a realistic effective focal spot size for use in MC simulations of very small diameter beams.  相似文献   

17.
Araki F 《Medical physics》2006,33(8):2955-2963
This study investigated small-field dosimetry for a Cyberknife stereotactic radiosurgery system using Monte Carlo simulations. The EGSnrc/BEAMnrc Monte Carlo code was used to simulate the Cyberknife treatment head, and the DOSXYZnrc code was implemented to calculate central axis depth-dose curves, off-axis dose profiles, and relative output factors for various circular collimator sizes of 5 to 60 mm. Water-to-air stopping power ratios necessary for clinical reference dosimetry of the Cyberknife system were also evaluated by Monte Carlo simulations. Additionally, a beam quality conversion factor, kQ, for the Cyberknife system was evaluated for cylindrical ion chambers with different wall material. The accuracy of the simulated beam was validated by agreement within 2% between the Monte Carlo calculated and measured central axis depth-dose curves and off-axis dose profiles. The calculated output factors were compared with those measured by a diode detector and an ion chamber in water. The diode output factors agreed within 1% with the calculated values down to a 10 mm collimator. The output factors with the ion chamber decreased rapidly for collimators below 20 mm. These results were confirmed by the comparison to those from Monte Carlo methods with voxel sizes and materials corresponding to both detectors. It was demonstrated that the discrepancy in the 5 and 7.5 mm collimators for the diode detector is due to the water non-equivalence of the silicon material, and the dose fall-off for the ion chamber is due to its large active volume against collimators below 20 mm. The calculated stopping power ratios of the 60 mm collimator from the Cyberknife system (without a flattening filter) agreed within 0.2% with those of a 10 X 10 cm2 field from a conventional linear accelerator with a heavy flattening filter and the incident electron energy, 6 MeV. The difference in the stopping power ratios between 5 and 60 mm collimators was within 0.5% at a 10 cm depth in water. Furthermore, kQ values for the Cyberknife system were in agreement within 0.3% with those of the conventional 6 MV-linear accelerator for the cylindrical ion chambers with different wall material.  相似文献   

18.
19.
Ding GX 《Medical physics》2004,31(9):2527-2533
Our purpose in this study was to investigate whether the Monte Carlo simulation can accurately predict output factors in air. Secondary goals were to study the head scatter components and investigate the collimator exchange effect. The Monte Carlo code, BEAMnrc, was used in the study. Photon beams of 6 and 18 MV were from a Varian Clinac 2100EX accelerator and the measurements were performed using an ionization chamber in a mini-phantom. The Monte Carlo calculated in air output factors was within 1% of measured values. The simulation provided information of the origin and the magnitude of the collimator exchange effect. It was shown that the collimator backscatter to the beam monitor chamber played a significant role in the beam output factors. However the magnitude of the scattered dose contributions from the collimator at the isocenter is negligible. The maximum scattered dose contribution from the collimators was about 0.15% and 0.4% of the total dose at the isocenter for a 6 and 18 MV beam, respectively. The scattered dose contributions from the flattening filter at the isocenter were about 0.9-3% and 0.2-6% of the total dose for field sizes of 4x4 cm2-40x40 cm2 for the 6 and 18 MV beam, respectively. The study suggests that measurements of head scatter factors be done at large depth well beyond the depth of electron contamination. The insight information may have some implications for developing generalized empirical models to calculate the head scatter.  相似文献   

20.
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface distances. Furthermore, Monte Carlo-generated output factors for both open and wedged fields agreed with linac commissioning beam data within statistical uncertainties of the calculations (<3% at largest depths). Compensating filters of both low-density and high-density materials have also been successfully simulated. As a demonstration, a wax compensating filter with a complex three-dimensional concave and convex geometry has been modelled through a CT scan import. Calculated depth doses and lateral dose profiles for different field sizes agreed well with experiments. The code was used to investigate the performance of a commercial treatment planning system in designing compensators. Dose distributions in a heterogeneous water phantom emulating the head and neck region were calculated with the convolution-superposition method (pencil beam and collapsed cone implementations) and compared against those from the MC code developed herein. The new technique presented in this work is versatile, DICOM-RT compliant and accurate in the simulation of beam modulators. This paper addresses the need to reduce the sources of error in the modelling of beam modifiers since they remain a viable alternative to the MLC technique in the delivery of IMRT beams.  相似文献   