首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two panels consisting of 236 and 258 anti-LAV/HTLV III positive and 64 and 50 negative sera, respectively (determined in Western blots), were tested with 8 different, commercially available ELISA test kits for detecting LAV/HTLV III antibodies (Abbott, Dupont, Electro-Nucleonics, Litton, Organon, Pasteur, Sorin, Wellcome). Positive sera were selected for levels of antibodies ranging from average to very high, and the negative sera included both negative sera and sera with antibodies to cellular components such as HLA antigens or nuclear membranes. In examination of the 2 panels, the sensitivity of the tests ranged from 97.2 to 100%, and the specificity from 70.0 to 100%. No test was ideal.  相似文献   

2.
Laboratory testing for Human T‐lymphotropic Virus type 1 and 2 (HTLV‐1 and ‐2) infections has become routine in blood transfusion, tissue transplantation and clinical diagnoses in many countries worldwide. Screening is usually based on the detection of antibodies to HTLV‐1 and/ or ‐2. The number of commercially available assays is limited, and among them, ELISA tests based on microtiter format are most commonly used. Recently, the new rHTLV‐I/II assay (Abbott Laboratories, Abbott Park, IL) was released; this assay was developed for an automatic large‐scale screening platform. This assay was evaluated using pre‐characterized serum panels and routine samples from the clinical laboratory. The sensitivity was 100% for HTLV‐1 and ‐2 (99/99 and 42/42, respectively, including one sample that was dually reactive, HTLV‐1 + 2). To test assay specificity, panels of blood donor sera, specimens from patients with autoimmune diseases and some viral infections were used. False‐reactive samples from previous HTLV diagnoses were also included. With these panels, the specificity was 99.4% (619/623). However, the four false‐reactive samples all belonged to the group of samples that were previously considered as false‐reactive for HTLV‐antibodies. All other samples were negative by the rHTLV‐I/II assay, and thus 100% specificity was obtained. The 1,412 samples tested in the clinic by this assay in routine use were all negative (100% specificity). Taken together, the overall specificity was 99.8%. The assay was sensitive, specific and appropriate for the large‐scale screening of samples for HTLV‐1/2 antibodies. J. Med. Virol. 82:1606–1611, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

3.
An enzyme immunoassay (EIA), designed to detect antibodies to human T-cell lymphotropic virus type III (HTLV III), was evaluated. The antibody test was found to be highly sensitive; serum from 221 of 223 (99.1%) patients with acquired immune deficiency syndrome (AIDS) was positive for antibodies to HTLV III. In addition, the antibody test was found to be highly specific; approximately 99.75% of 20,720 serum or plasma samples from blood donors were negative for antibody to HTLV III. In most cases, the Western Blot analysis agreed well with the EIA. Eighty-one of 82 (98.8%) EIA-positive samples from patients with AIDS were Western Blot positive. Of the EIA-positive blood donors, 21 of 36 (58%) were detected and confirmed by Western Blot analysis. A solid-phase competitive EIA also was evaluated as an alternate procedure. The preliminary results indicate that this immunoassay has a high degree of sensitivity and specificity and could serve as an alternate procedure to detect antibody to HTLV III.  相似文献   

4.
The purpose of this study was to assess whether the LG Anti-HIV 1/2 Plus ELISA (LG Life Sciences, Seoul, Korea), a new third-generation enzyme-linked immunosorbent assay for the detection of HIV infection, has improved sensitivity and specificity in comparison to the other licensed third-generation assays. The sensitivity of the LG Anti-HIV 1/2 Plus ELISA was comparable to the Enzygnost Anti-HIV 1/2 Plus ELISA (Dade Behring, Marburg, Germany) (100% vs 100%), and it was capable of detecting highly divergent subtypes including HIV-1 group O. The specificity of the LG Anti-HIV 1/2 Plus ELISA was 100%. The concordance of the LG Anti-HIV 1/2 Plus ELISA and the Enzygnost Anti-HIV 1/2 Plus was found to be 1. The LG Anti-HIV 1/2 Plus ELISA has a short window period among the third-generation ELISA assays and this test showed satisfactory reproducibility.  相似文献   

5.
Serum specimens were tested for HIV antibodies by two commercially available ELISAs (Abbott HTLV III EIA and Du Pont HTLV III-ELISA). The specificity and sensitivity of these assays were determined by comparison with indirect immunofluorescence and Western blot analysis. Specificity ranged from 94.3% in the Abbott assay to 97.9% in the Du Pont-ELISA. The sensitivity was 100% in the Abbott-ELISA and 99% in the Du Pont test. With both tests, false-positive results occurred predominantly in sera from patients with immunological disorders (kidney transplant recipients, lymphoma, Stevens-Johnson syndrome, etc.), whereas symptomatic AIDS-patients, patients with ARC, and persons with a defined risk for HIV infection could be diagnosed unequivocally. Specificity and sensitivity of anti-HIV ELISAs seemed to depend not only on definition of the cutoff value but also on other factors, such as antigen preparation and inactivation measures. Testing of ELISA-reactive sera by confirmatory tests remains necessary.  相似文献   

6.
Monomeric and chimeric synthetic peptides were used as coating antigens in four different mixtures in a solid phase immunoassay to select an optimal combination for the detection of antibodies to human T-cell lymphotropic virus (HTLV) in serum samples. The peptides, P-13 (gp21 I), Q5 (gp21 II)-GG-(gp46 II), and Q (gp46 I)-GG-(p19 I), represent immunodominant sequences from transmembrane protein (gp21), envelope protein (gp46), and core protein (p19) of HTLV I/II viruses; they were the most antigenic and specific peptides in previous studies. The sequences of the chimeric peptides were separated by two glycine residues. An indirect UltramicroEnzyme-linked immunosorbent assay (UMELISA) was used to evaluate the antigenicity of these peptide mixtures by using samples from anti-HTLV I/II PRP205(M), (n = 20), HTLV I-infected individuals from Cuba (n = 7), and HTLV I-positive sera from Colombia and Chile (n = 9). The specificity was evaluated with healthy blood donor sera (n = 300), anti-HIV 1-positive samples (n = 10), and other seropositive samples to different infectious agents. The highest sensitivity and specificity was obtained with mixture 1, which could be very useful in the immunodiagnostic of HTLV infection.  相似文献   

7.
Synthetic peptides, derived from the amino acid sequence of a Leishmania donovani clone, were used to develop an enzyme-linked immunosorbent assay (ELISA) for detecting antibodies against L. donovani. For this purpose, five peptides were conjugated to a protein carrier, human serum albumin (HSA), by using a heterobifunctional reagent, epsilon-maleimidocaproic acid N-hydroxysuccinimide ester, to obtain a well-defined product. The sensitivity and the specificity of the peptide-specific ELISA were determined with a panel of 106 serum samples from individuals living in areas where visceral leishmaniasis is endemic; sera from post-kala azar dermal leishmaniasis-infected patients and from individuals suffering from other infectious diseases were also included. ELISAs were performed with either a single peptide-HSA conjugate or a mixture of two peptide-HSA conjugates. Ninety-seven percent of the serum samples from patients with visceral leishmaniasis had detectable antibodies to one or more of the single synthetic peptides. ELISA with a single peptide-HSA conjugate proved to be less sensitive (less than 71%) but more specific (up to 93%) than ELISA with crude promastigote antigens (80% sensitivity and 79% specificity); when a combination of two different peptide-HSA conjugates was used, the test increased both in sensitivity and in specificity. Chemically defined peptide-protein conjugates improve the reproducibility and reliability of ELISA for the serodiagnosis of L. donovani infection.  相似文献   

8.
Immunoassays based on the highly immunogenic transmembrane protein of human T-cell lymphotropic virus type 1 (HTLV-1) (protein 21c) are capable of detecting antibodies in all individuals infected with HTLV-1 and HTLV-2. However, because of antigenic mimicry with other cellular and viral proteins, such assays also have a large proportion of false-positive reactions. We have recently identified an immunodominant epitope, designated GD21-I located within amino acids 361 to 404 of the transmembrane protein, that appears to eliminate such false positivity. This recombinant GD21-I protein was used in conjunction with additional recombinant HTLV type-specific proteins and a whole virus lysate to develop a modified Western blot (immunoblot) assay (HTLV WB 2.4). The sensitivity and specificity of this assay were evaluated with 352 specimens whose infection status was determined by PCR assay for the presence or absence of HTLV-1/2 proviral sequences. All HTLV-1-positive (n = 102) and HTLV-2-positive (n = 107) specimens reacted with GD21-1 in the HTLV WB 2.4 assay, yielding a test sensitivity of 100%. Furthermore, all specimens derived from individuals infected with different viral subtypes of HTLV-1 (Cosmopolitan, Japanese, and Melanesian) and HTLV-2 (IIa0, a3, a4, IIb1, b4, and b5) reacted with GD21-I in the HTLV WB 2.4 assay. More importantly, HTLV WB 2.4 analysis of 81 PCR-negative specimens, all of which reacted to recombinant protein 21e in the presence or absence of p24 and p19 reactivity in the standard WB assay, showed that only two specimens retained reactivity to GD21-I, yielding an improved test specificity for the transmembrane protein of 97.5%. None of 41 specimens with gag reactivity only or 21 HTLV-negative specimens demonstrated reactivity to GD21-I. In an analysis of additional specimens (n = 169) from different geographic areas for which PCR results were not available, a substantial increase in the specificity of GD21-I detection was demonstrated, with no effect on the sensitivity of GD21-I detection among specimens from seropositive donors. Thus, the highly sensitive, GD21-I-based HTLV WB 2.4 assay eliminates the majority of false-positive transmembrane results, thereby increasing the specificity for serologic confirmation of HTLV-1 and HTLV-2 infections.  相似文献   

9.
Summary The clinical, immunological, and serological status of 28 patients with hemophilia A and of 13 patients with hemophilia B was investigated. Thirty-four patients were treated regularly by clotting factor concentrates and 7 patients had been substituted only 1 to 4 times. Almost all patients with severe hemophilia suffered from hepatopathy. No patient had clinical evidence of the acquired immunodeficiency syndrom (AIDS).Asymptomatic hemophiliacs showed a decreased number of T-helper (OKT 4) cells and an increased number of T-suppressor (OKT 8) cells, which resulted in an inversed OKT 4/OKT 8 cell ratio. Natural killer cell activity of all patients was decreased compared to controls. After culture there was no significant difference of NK cell activity between hemophiliacs and controls. This phenomen was interpreted as a possible maturation defect of NK-cells in vivo.No relationship between immunological alterations and hepatopathy, hepatitis markers, CMV antibodies, amount and source of required factor concentrates, and the kind of hemophilia was observed. IgG immunoglobulins were higher and the OKT 4/OKT 8 ratio lower in the eight patients with lymphadenopathy than in patients without lymphadenopathy. The prevalence of antibodies to human T-lymphotropic virus (HTLV III) was measured in 35 hemophiliacs and in 25 polytransfused patients, most of whom were suffering from acute leukemia. In 8 of 35 hemophiliacs antibodies to HTLV III virus were detected by an enzyme linked immunosorbent assay (ELISA) and confirmatory tests. All seropositive patients were treated by blood products from the United States. Eight hemophiliacs treated by factor concentrates from German donors only were seronegative. In comparison 2 of 25 examined non-hemophilia patients receiving multiple blood products from local donors were seropositive for HTLV III. The results show that hemophilia patients treated by imported clotting factor concentrates have a high risk of HTLV III positivity. Hemophiliacs substituted by blood products obtained by local donor pools have only a small risk of infection. Because non-hemophiliac polytransfused patients had HTLV III antibodies, there must be asymptomatic virus carriers in the local donor pool. The HTLV III antibody screening of all donors and the heat treating of factor concentrates will give better therapeutic safety.Abbreviations AIDS Acquired immunodeficiency syndrome - ALT Alanin-Aminotransferase - Anti-HBc Antibody to hepatitis B core antigen - Anti-HBs Antibody to hepatitis B surface antigen - AST Aspartat-Aminotransferase - CMV Cytomegaly virus - EBV Epstein-Barr-virus - EDTA Ethylendiamintetraacetate - ELISA Enzyme linked immunosorbent assay - -GT Gamma-Glutamyl-Transferase - HBsAg Hepatitis B surface antigen - HLA Human Leukocyte Antigen - HTLV III Human T-lymphotropic virus - IL-2 Interleukin 2 - IPS Immune peroxidase staining - LDH Lactat-Dehydrogenase - LGL Large granular lymphocyte - LU30 Lytic units - MNC Mononuclear cells - NK Natural Killer cells - OKT 3 Total T-cells - OKT 4 T-helper cells - OKT 8 T-suppressor cells  相似文献   

10.
The characteristics of primary (first) tests with three enzyme-linked immunosorbent assay (ELISA) kits for human immunodeficiency virus (HIV) antibody were determined. The three ELISAs were performed on 3,229, 3,130, and 685 specimens from high-risk individuals using the Litton (LT; Litton Bionetics Laboratory Products, Charleston, S.C.), Dupont (DP; E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.), and Genetic Systems (GS; Genetic Systems, Seattle, Wash.) kits, respectively. Evaluation was based on the distribution of quantitative test results (such as optical densities), a comparison with Western blot (WB) results, reproducibility of the tests, and identification of seroconverters. The performances of the GS and the DP kits were good by all four criteria and exceeded that of the LT kit. Primary ELISA-negative results were not always confirmed with repeat ELISA and by WB testing. The largest percentage of these unconfirmed negative test results came from samples with quantitative results in the fifth percentile nearest the cutoff. Thus, supplementary testing was indicated for samples with test results in this borderline negative range. Similarly, borderline positive primary ELISA results that were quantitatively nearest (fifth percentile) the cutoff value were more likely to be antibody negative on supplementary testing than samples with high antibody values. In this study, results of repeated tests by GS ELISA showed the least change from first test results. DP ELISA showed more unconfirmed primary positive test results, and LT ELISA showed more unconfirmed primary negative test results. Designation of a specimen with a single ELISA quantitative level near the cutoff value as positive or negative should be viewed with skepticism. A higher than normal proportion of specimens with high negative optical densities by GS ELISA (fifth percentile nearest the cutoff) and also negative by WB were found to be from individuals in the process of seroconversion.  相似文献   

11.
The sensitivity, reproducibility and specificity of an enzyme-linked immunosorbent assay (ELISA) for the defective phage PBS Z1 of Bacillus subtilis have been investigated. It was shown that phages in concentrations between 10(8) and 2.5 X 10(10) particles/ml could be assayed with this method. The coefficient of variation for concentrations between 5 X 10(8) and 5 X 10(9) particles/ml was approx. 10%. From some other Bacillus phages tested, only the defective phages resembling PBS Z1 in morphology were detected efficiently with the ELISA for PBS Z1. A comparison is made between ELISA and other assays for PBS Z1.  相似文献   

12.
A strategy was developed for the control, standardization, and critical evaluation of an enzyme-linked immunosorbent assay (ELISA) for the detection of human papillomavirus-specific immunoglobulin G in human sera. Control human sera, polyclonal animal sera, and monoclonal antibodies were used to establish optimal assay parameters, including antigen coating, serum dilutions, and criteria for daily reproducibility, monitoring, and rejection of assays. Three evaluation techniques were used in parallel to define an optimal cutoff absorbance value that yields greater than 93% sensitivity and 98.5% specificity in the assay's ability to discriminate positive and negative control sera. This strategy provides an optimal method by which to determine cutoff absorbance values for ELISA.  相似文献   

13.
A strategy was developed for the control, standardization, and critical evaluation of an enzyme-linked immunosorbent assay (ELISA) for the detection of human papillomavirus-specific immunoglobulin G in human sera. Control human sera, polyclonal animal sera, and monoclonal antibodies were used to establish optimal assay parameters, including antigen coating, serum dilutions, and criteria for daily reproducibility, monitoring, and rejection of assays. Three evaluation techniques were used in parallel to define an optimal cutoff absorbance value that yields greater than 93% sensitivity and 98.5% specificity in the assay's ability to discriminate positive and negative control sera. This strategy provides an optimal method by which to determine cutoff absorbance values for ELISA.  相似文献   

14.
Immunoassay systems using monoclonal antibodies (mAbs) are one of the most useful techniques in the analytical, biochemical, and clinical fields. In this study, a combination enzyme-linked immunosorbent assay (ELISA) using both anti-glycyrrhizin and anti-liquiritin mAbs (anti-GL/Liq mixture mAbs) was developed for quality control of licorice and its products. The combination ELISA demonstrated high sensitivity, reproducibility, and specificity for the total content of GL and Liq by a single assay. The developed ELISA was effective and useful as the first screening method in the selection of high-quality licorice from the Glycyrrhiza species and in confirming the quality of licorice-containing Kampo medicines.  相似文献   

15.
Junin virus is the etiological agent of Argentine hemorrhagic fever, a serious rodent-borne disease. An enzyme-linked immunosorbent assay (ELISA) to detect Junin virus IgG antibodies in rodents was evaluated using sera from 27 Calomys musculinus and five Calomys laucha, inoculated experimentally with a live attenuated strain of this arenavirus. The test performance was compared against an indirect immunofluorescence assay (IFA). The ELISA had a sensitivity and specificity of 100% and a reproducibility of 87.9% for samples with titers above the selected cut-off value. IFA had lower sensitivity (53%) with the same specificity. The ELISA results were similar, whether carried out on whole blood or serum samples, thus eliminating the need for serum separation. A high correlation (K=0.86) between ELISA and IFA results was obtained from 1011 wild sigmodontine and murine rodents collected within and outside of the Argentine hemorrhagic fever endemic area. These results indicate that Junin virus IgG ELISA is the most suitable assay for detection of Junin virus antibodies in rodent samples.  相似文献   

16.
A new direct immunofluorescence reagent (Syva and Genetic Systems Inc) was evaluated for its ability to detect Neisseria gonorrhoeae in specimens from populations with a high prevalence of the infection. Gonorrhoea was diagnosed by culture in 45 of 105 (43%) urethral specimens from men and 17 of 90 (28%) urethral and 25 of 60 (42%) cervical specimens from women. In men the immunofluorescence test had a sensitivity of 84.4% and a specificity of 100%; Gram staining gave values of 94% and 100%, respectively. The sensitivity of the immunofluorescence test could be increased to 89% by testing duplicate smears. In women the immunofluorescence test had a sensitivity of 65% and a specificity of 98% for urethral samples and values of 72% and 94%, respectively for cervical samples. At both sites the sensitivity of the Gram stain was 40% and the specificity 100%. The testing of duplicate immunofluorescence smears increased the sensitivity to 76% for urethral and 88% for cervical samples.  相似文献   

17.
Human T-cell lymphotropic viruses designated HTLV III or LAV are considered to represent the causative agent(s) of the acquired immunodeficiency syndrome (AIDS). Individuals who have been infected with these viruses may generally be identified on the basis of a positive serological test for antibodies against the protein components of these viruses. Purified viruses or viral proteins have been utilized for developing such tests. Since AIDS may be transmitted by blood transfusion and by blood products, screening of donors for antibodies to HTLV III/LAV has become a necessity. Such screening may be facilitated by the application of assays based on the use of crude virus-infected tissue culture media avoiding elaborate, expensive and potentially hazardous virus purification steps. Serum specimens were mixed with an appropriate dilution of an HTLV III-infected tissue culture-derived fraction, obtained by precipitation with polyethylene glycol 6000 and treatment with Tween 80 and tri-n-butylphosphate (to disrupt virus particles), and incubated with polystyrene beads coated with antibodies to HTLV III/LAV (anti-HTLV III). Subsequently, washed beads were incubated with either 125I- or beta-lactamase-labeled anti-HTLV III. The radioactivity or enzymatic activity associated with the beads was proportionate to the quantity of HTLV III antigen originally added to the beads. The presence of anti-HTLV III in serum specimens resulted in decreased antigen binding and thus in decreased radioactivity or diminished beta-lactamase activity associated with the beads. The test was specific for antibodies to the approximately equal to 24 kDa core protein of HTLV III. The prevalence of these antibodies (given in parentheses) in distinct populations was as follows: random blood donors (0.33%); hemophiliacs (36.4%); random homosexual males (25.1%); homosexual males preselected on the basis of positive markers for infection with hepatitis B virus (50%); and those with persistent lymphadenopathy (70%).  相似文献   

18.
Taiwan suffered from the outbreak of severe acute respiratory syndrome (SARS) in 2003. Our laboratory performed a series of virology and serology tests for SARS patients admitted to our hospital. Cross-reactivity was found when testing for antibody against human T-cell lymphotropic virus (HTLV) in one patient with SARS. Therefore, antibodies against HTLV were examined in paired-sera from 26 SARS patients. ELISA and a neutralization test were used to measure anti-SARS antibodies. Seroconversion for antibody against SARS-CoV was observed in all patients. Surprisingly, with the use of ELISA for HTLV, sera for 13 patients were positive for HTLV (50%), and seroconversion for HTLV was also observed in 10 patients (38.5%). Western blot for HTLV on those 26 paired-sera from 13 HTLV-positive patients displayed 5 positive results for HTLV-I, 7 positive results for HTLV-II, 1 positive result for both HTLV-I and II, 9 negative results for either HTLV-I or HTLV-II, and 4 "indeterminate" results. The findings that antibody to HTLV can be detected in blood samples collected from SARS patients provide important information for safe handling of blood products. Without such knowledge, blood products can be discarded mistakenly even though they contain anti-SARS-CoV antibodies that may be potentially valuable for SARS therapy.  相似文献   

19.
An enzyme-linked immunosorbent assay (ELISA) was developed for detecting antibodies against Trypanosoma cruzi. Two synthetic T. cruzi peptides, TcD and PEP2, were used. The specificity and sensitivity of the peptide ELISA were determined with 260 serum samples from individuals living in an area in which Chagas' disease is endemic. ELISAs were performed with the peptides singly or in combination. The evaluation of these tests showed that 168 (93.8%) of 179 serum samples from T. cruzi-infected patients were positive when TcD peptide was used as antigen; 164 (91.6%) samples were positive with PEP2, and 178 (99.4%) samples were positive when the two peptides were combined. Thus, the sensitivity of the ELISA using the two peptides exceeded 99%. The specificity was evaluated by using a panel of 118 serum samples that included samples from 81 individuals living in an area of endemicity with negative serology for Chagas' disease and from 37 patients from areas in which T. cruzi was not endemic but with other pathologies, such as leishmaniasis, tuberculosis, and leprosy. Only two false-positive serum samples were found in this group of individuals, giving a test specificity of more than 98%. Because these peptides can be synthesized and are very stable at room temperature, the use of such reagents can improve the standardization and reproducibility of ELISAs for the serodiagnosis of T. cruzi infection.  相似文献   

20.
A competitive type-specific enzyme-linked immunosorbent assay (ELISA) for herpes simplex virus type 2 (HSV-2) antibody was developed using an infected cell antigen and a monoclonal antibody to glycoprotein G-2. This assay has been validated for use for epidemiological studies using a large panel of sera collected in rural Uganda and a panel of 143 sera characterised previously by Western blotting, the 'gold standard' for HSV type-specific serology. This evaluation was found to have a sensitivity of 96% and a specificity of 91% in comparison with Western blot on 143 sera from clinic patients. The ELISA had a sensitivity of 93% and a specificity of 91% in comparison with Western blot on 495 sera collected in Uganda. The assay showed good reproducibility and a low percentage of sera gave equivocal results, indicating its suitability for epidemiological studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号