首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
We developed a sandwich enzyme-linked immunosorbent assay to detect circulating parasite antigen in humans with fascioliasis. The assay uses antibodies against Fasciola hepatica excretory secretory (ES) antigens. A monoclonal antibody was used to capture circulating ES antigens, and a human polyclonal antibody peroxidase conjugate was used to identify circulating ES antigens. Optimal dilutions of all reagents were determined by block titration. The antigen concentration in sera from patients was estimated by comparing the optical density at 492 nm of test sera with a standard curve. All of the serum samples from 25 patients with parasitological evidence of fascioliasis had a detectable antigen concentration (more than 10 ng/ml). None of the serum samples from 80 patients infected with parasites other than F. hepatica showed a positive reaction, suggesting the absence of cross-reactions in this assay.  相似文献   

2.
An enzyme-linked immunosorbent assay (ELISA) was developed which detected soluble antigens from culture extracts of Legionella pneumophila serogroups 1 to 8, L. micdadei, L. bozemanii serogroups 1 and 2, L. dumoffii, L. gormanii, L. longbeachae serogroups 1 and 2, L. wadsworthii, L. oakridgensis, L. anisa, L. feeleii serogroup 1, and L. jordanis. The assay was approximately 10-fold more sensitive for the eight L. pneumophila serogroups than for the other Legionella species tested. The ELISA detected Legionella antigens in the urine specimens of 25 of 35 patients with L. pneumophila serogroup 1, 3, 4, 6, and 8; L. micdadei; and L. longbeachae serogroup 1 infections. None of the 334 urine specimens from patients with either non-Legionella pneumonia or urinary tract infections was positive. For 10 patients from whom sequential urine specimens were available, Legionella antigens were not detectable from 7 to 19 days after laboratory diagnosis. Test sensitivity was not affected by heavy bacterial contamination. This ELISA offers the detection of a broad spectrum of Legionella antigens by a single test.  相似文献   

3.
Patients with massive liver cell necrosis that may follow halothane anaesthesia have a high incidence of circulating antibodies against halothane-induced hepatocyte antigens. In order to provide an objective and quantitative method for the detection of these antibodies, an enzyme-linked immunosorbent assay has been developed. Sera, after absorption with normal rabbit liver microsomal fraction, are tested for binding to microsomal fractions from control and halothane-pretreated rabbits. Those containing antibodies against halothane-induced determinants give significantly enhanced binding to halothane-altered fractions; this specificity was verified by absorption experiments. Using this method, halothane-related antibodies were detected in sera from 16/24 patients with halothane-associated liver failure, at titres ranging from 1:100 to 1:25600. Such antibodies were not detectable in sera from 26 normal blood donors, 5 healthy anaesthetists, 12 patients who had received multiple halothane anaesthetics but had normal liver function tests and 32 patients with a variety of other liver diseases. This rapid and reproducible assay should be of value for the detection of antibodies and for detailed investigation of patient antibody responses, and also for characterization of the route of production and metabolism of the antigen.  相似文献   

4.
An indirect sandwich enzyme-linked immunosorbent assay, using antibody covalently coupled to nylon beads, has been adapted for the detection of Brucella antigens. Optimum conditions were achieved by incubation of 1 ml of reaction mixture with a single bead, and by minimizing nonspecific interactions through the use of beads coated with purified bovine antibodies, preabsorption of third layer rabbit antibodies with normal bovine serum, and treatment of beads with normal goat serum before addition of the goat anti-rabbit enzyme conjugate. Beta-galactosidase was selected for use with clinical samples primarily because of low levels of endogenous enzyme in bovine leukocytes. Use of a fluorogenic substrate enhanced sensitivity 20-fold. Under these conditions, 100 fg of solubilized crude lipopolysaccharide or 8 to 10 Brucella cells was detectable in a fixed volume of 1 ml. A system was also devised for concentrating antigen which permitted ready detection of 2 pg of lipopolysaccharide in a volume of 50 ml (40 fg/ml). Attempts to detect lipopolysaccharide in the presence of concentrated serum or plasma were unsuccessful, but 10 brucellae added to a suspension of leukocytes from 100 ml of normal bovine blood were easily measured.  相似文献   

5.
A homemade enzyme-linked immunosorbent assay (ELISA) (Academic Medical Center ELISA [AMC-ELISA]) and a dipstick assay for the detection of anti-Strongyloides stercoralis antibodies in serum were developed and evaluated together with two commercially available ELISAs (IVD-ELISA [IVD Research, Inc.] and Bordier-ELISA [Bordier Affinity Products SA]) for their use in the serodiagnosis of imported strongyloidiasis. Both commercially available ELISAs have not been evaluated previously. The sensitivities of the assays were evaluated using sera from 90 patients with parasitologically proven intestinal strongyloidiasis and from 9 patients with clinical larva currens. The sensitivities of the AMC-ELISA, dipstick assay, IVD-ELISA, and Bordier-ELISA were 93, 91, 89, and 83%, respectively, for intestinal strongyloidiasis. In all tests, eight of nine sera from patients with larva currens were positive. The specificity was assessed using a large serum bank of 220 sera from patients with various parasitic, bacterial, viral, and fungal infectious diseases; sera containing autoimmune antibodies; and sera from healthy blood donors. The specificities of AMC-ELISA, dipstick assay, IVD-ELISA, and Bordier-ELISA were 95.0, 97.7, 97.2, and 97.2%, respectively. Our data suggest that all four assays are sensitive and specific tests for the diagnosis of both intestinal and cutaneous strongyloidiasis.  相似文献   

6.
A sandwich ELISA for the detection of herpes simplex virus (HSV) antigens was developed using sheep anti-HSV F(ab')2 fragments for capture and an indirect antibody system for detection. Current detection limits are 0.5 ng protein for HSV1 and 1.5 ng protein for HSV2. This compares to a single HSV1-infected Vero-cell in a background of 10(6) non-infected cells or 10 plaque forming units (PFU) of HSV1 in culture supernatants as determined in separate experiments. Limiting dilution experiments show that one PFU of HSV1 can be detected after overnight culture in both supernatant and cell extracts. The use of F(ab')2 for capture completely eliminated binding of Staphylococcus aureus. No cross-reactivity was observed with other human herpes viruses. When evaluated with 245 random 'left-overs' of genital swab specimens in transport medium the test showed a sensitivity and specificity of 77.2 and 97.8%, respectively, with respect to virus isolation in culture. In a preliminary study on 16 direct ELISA swab-specimens extracted in 0.5 ml ELISA sample buffer both sensitivity and specificity were 100% with respect to culture. In both clinical series there was a proportional relationship between the ELISA value and the estimated amount of infectious virus in the specimen.  相似文献   

7.
Quantitation of nasal secretory IgA by enzyme-linked immunosorbent assay   总被引:1,自引:0,他引:1  
Sites at which positive skin-test reactions have been elicited exhibit an accelerated (so-called 'retest') reaction upon local reinjection of the antigen used for primary skin testing. When using a peritoneal cavity inflammation model in guinea pigs, local migration inhibition factor (MIF) release in vivo was studied in both primary and retest reactions to purified protein derivative. Increased retest reactivity could be demonstrated to coincide with an instantaneous and intense local MIF release. Estimation of both the absolute number of the antigen specificity of lymphocytes present in the peritoneal cavity at the time of retesting (170 h after primary testing) showed that the early burst of MIF release is primarily due to nonspecific local retention of increased numbers of lymphocytes.  相似文献   

8.
The purpose of this study was to evaluate, in Kaposi's sarcoma patients, the correlation between antibody titers to the lytic antigens of human herpesvirus 8, as assessed by immunofluorescence assay, and values obtained by an enzyme immunoassay. The methods showed a stringent correlation, r = 0.625 (P<0.001).  相似文献   

9.
Further studies of a four-step enzyme-linked immunosorbent assay procedure to detect Treponema pallidum antibody are described. High-titered antibody, produced in rabbits by intravenous injection of T. pallidum, was used to coat polyvinyl chloride microtiter plates. To these plates a known concentration of T. pallidum was added, followed in successive steps by serial dilutions of human sera and appropriately diluted peroxidase-labeled anti-human immunoglobulin G antibody. O-Phenylenediamine was the substrate. A total of 340 sera were obtained from the DeKalb County Sexually Transmitted Diseases Clinic, Atlanta, Ga., and examined within 3 days of receipt. Ninety-six percent test agreement between the enzyme-linked immunosorbent assay and the fluorescent treponemal antibody absorption-double staining test was obtained. A total of 372 additional sera stored at -20 degrees C were examined. The overall sensitivity of the enzyme-linked immunosorbent assay with sera from patients with various stages of syphilis was 96%. With sera from uninfected individuals, the specificity of the enzyme-linked immunosorbent assay was 95%. No antigen instability was noted with the two antigen preparations used during this evaluation.  相似文献   

10.
Summary An enzyme-linked immunosorbent assay (ELISA) was employed to investigate the expression of influenza A/Hong Kong/68 (H3N2) virus structural proteins on the surface of infected MDCK cells, and to detect viral antigens in culture media and cell extracts. Infected cells were fixed with 0.1 per cent glutaraldehyde before being examined for the presence of cell-surface antigens. Viral antigens were first observed on the surface of cells 4 hours after infection and reached a maximum 10–12 hours after infection, when measured by haemadsorption with chicken erythrocytes and by ELISA and immunofluorescence with hyperimmune antiserum to Hong Kong virus. A good correlation was found between the three assay systems. The presence of individual virion structural proteins on the cell surface was determined by ELISA using specific antibodies purified by differential affinity chromatography. Either or both of the internal matrix and nucleoprotein antigens were expressed from 2 to 6 hours after infection, with maximum expression after 2 hours, and the strain-specific and common antigenic determinants of haemagglutinin were observed on the cell surface from 4 hours after infection, and reached a maximum 8 to 10 hours after infection. Low levels of neuraminidase were detected between 4 and 8 hours after infection. Culture media and cell extracts were titrated by infectivity and haemagglutination assays, and by ELISA. Titres obtained from the culture media showed a close correlation between the three assay methods, with peak titres being attained 24 hours after infection. Viral antigens were first observed in cell extracts by ELISA 4 hours after infection, and infectious virions and haemagglutinin 2 hours later, but whereas maximum titres of infectious virus and haemagglutinin were found 10 hours after infection, the ELISA titre continued to rise until 24 hours after infection, which suggested that virus structural proteins were being accumulated in the cells after most of the progeny virions had been released. The results are discussed in terms of the potential use of ELISA in rapid virus diagnosis.The results of comparative assays on cell extracts harvested at various times after infection indicated that virion structural proteins continue to be accumulated in the cell even after most progeny particles have matured. Moreover, the high correlation coefficients between infectivity, haemagglutination and ELISA of virus particles and antigens released into the culture media strongly suggest that only complete virus particles are released, and very little leakage of individual antigens occurred, even from dead cells.ELISA has also been successfully employed to detect other cell-associated viral antigens, including rabies virus in brain tissue (3) and feline oncornavirus-associated cell membrane antigen in FL74 cells (22). In the latter study, the ELISA titres showed a close correlation in sensitivity with indirect fluorescence tests, but had the added advantage of being quantitative rather than qualitative. The results presented in this report, together with those using other viruses (3, 19, 22) suggest that ELISA is a potentially useful technique for the detection of specific virus infections in tissue culture, and as a tool for rapid virus diagnosis. Problems have been encountered using peroxidase rather than alkaline phosphatase as the enzyme in ELISA due to endogenous peroxidase in clinical material (13), but no evidence of non-specific staining was observed in this study, probably because the cells had been fixed initially with glutaraldehyde. We believe, therefore, that this study has demonstrated that ELISA can be employed as a rapid technique to detect and to distinguish subtype specificity of influenza A virus in tissue culture, and can potentially be applied to other viruses with cell surface-associated antigens. Moreover, the use of glutaraldehyde-fixation allows considerable flexibility in the timing of the assay and may prove suitable for viral diagnosis at a distance.With 4 Figures  相似文献   

11.
A whole-bacterial cell enzyme-linked immunosorbent assay (bactELISA) was developed for detecting fimbrial antigens on Streptococcus sanguis. In this assay, S. sanguis cells were directly adhered to polystyrene or polyvinyl via drying. Use of the assay indicated that consistently high and uniform optical densities could be obtained from well to well. In addition, radioactive assaying indicated increased adsorption to the polystyrene wells over polyvinyl, suggesting that polystyrene may prove superior in the gram-positive bactELISA. Use of the bactELISA may prove valuable to both the clinical and research laboratory involved in the study of bacterial cell surface components or in the evaluation of antisera directed against bacterial antigens, which are difficult to prepare as purified derivatives.  相似文献   

12.
An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of hepatitis A virus in human fecal specimens. Investigations with 88 fecal specimens from 77 patients with suspected viral hepatitis and 8 of their household contacts showed that ELISA was as specific and sensitive as radioimmunoassay and almost as sensitive as immune electron microscopy. The ELISA is quick and simple to perform, does not require sophisticated technical equipment, and can be read with the naked eye, making it suitable for field work and rapid diagnosis.  相似文献   

13.
The performance of a direct sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was compared with that of the Pastorex Aspergillus antigen latex agglutination (LA) test by using 532 serum samples from 61 patients at risk for invasive aspergillosis. The ELISA gave positive results earlier in the course of infection than did the LA test. A sensitivity of 70% and a specificity of 86% were obtained for the LA test and corresponding values of 90 and 84% were obtained for the ELISA when a series of serum samples was employed.  相似文献   

14.
A solid-phase enzyme linked immunosorbent assay was developed for the detection of immunoglobulin M antibody to hepatitis A virus. The system was capable of detecting hepatitis A-specific immunoglobulin M in a single dilution of serum and appears to be a reliable and rapid means of establishing a diagnosis of hepatitis A infection. Specific immunoglobulin M was only detected in patients with serologically confirmed hepatitis A and not in patients with other forms of hepatitis, chronic liver disease, or autoimmune disease. In patients with hepatitis A, specific immunoglobulin M was usually detectable for 6 weeks after the onset of dark urine, and the longest period for which it was present in any patient was 115 days. This enzyme-linked immunosorbent assay is rapid, simple to perform, and does not require complicated equipment. Provided adequate supplies of purified reagents can be obtained, this enzyme-linked immunosorbent assay procedure is likely to simplify hepatitis A serology, because the same antibody-coated plates can be utilized to detect hepatitis A virus, anti-hepatitis A virus, and hepatitis A-specific immunoglobulin M.  相似文献   

15.
Secretory immunoglobulin A (SIgA) in serum is possibly the best index of SIgA presence in mucosal secretions in digestive tract and the mirror of its immunologic barrier against many pathogenic aggressions. The measurement of salivary SigA alone may be affected by total salivary secretion and its final concentration in the gland lumen is probably not useful as an appropriate index of mucosal secretions in the digestive tract. The usefulness of the determination of SigA against various epitopes in serum from patients with various autoimmune disease has been demonstrated. The aetiology of many digestive related disorders could be triggered by an alteration of mucose SIgA barrier. The determination of Igs is important for different liver diseases and specifically the SIgA in autoimmune diseases such as rheumatoid arthritis. We developed an easy and efficient immunologic assay to quantify SIgA in serum samples.  相似文献   

16.
A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis.  相似文献   

17.
Indirect enzyme-linked immunosorbent assay for zygomycosis.   总被引:2,自引:0,他引:2       下载免费PDF全文
A 2-h indirect enzyme-linked immunosorbent assay (ELISA) using homogenate antigens of Rhizopus arrhizus and Rhizomucor pusillus was developed and compared with the existing immunodiffusion (ID) test for zygomycosis, using homogenate antigens of R. arrhizus. Utilizing 1:400 as a minimally positive ELISA titer, 33 of 43 proven cases of zygomycosis were diagnosed. The sensitivity of the ELISA was 81%. The ID test, in contrast, detected only 21 cases and demonstrated a sensitivity of 66%. The specificity of the ELISA was 94%, whereas that of the ID test was 91%. Nonspecific ELISA reactivity was particularly evident with sera from patients with aspergillosis and candidiasis. With the antigens now available, the ELISA was unable to generically or specifically identify the etiologic agents.  相似文献   

18.
An enzyme-linked immunosorbent assay for the measurement of antibodies directed against Pseudomonas aeruginosa cell surface antigens was developed. Formalin-killed whole cells of P. aeruginosa, adsorbed to polystyrene acrylic copolymer cuvettes, were used as immobilized antigens. Antisera to P. aeruginosa mucoid strain 144M and to its spontaneous nonmucoid derivative, 144NM, were raised in rabbits by immunization with Formalin-killed bacteria. By using this enzyme-linked immunosorbent assay, anti-144M serum was found to have a ca. 10-fold-higher antibody titer to 144M than did anti-144NM serum, suggesting that 144M may have either immunogenic determinants not present on 144NM or perhaps simply more antigenic determinants. In contrast, anti-144M and anti-144NM immune sera were found to have nearly identical antibody titers to 144NM, suggesting that these strains share many determinants. Anti-P. aeruginosa immune serum was found to contain Pseudomonas-specific antibodies as well as antibodies which cross-reacted with other gram-negative bacteria. Finally, absorption studies demonstrated that this assay can detect both LPS and non-LPS surface-exposed antigenic determinants. Thus, this whole bacterial cell enzyme-linked immunosorbent assay should prove useful in monitoring patient sera and secretions for potentially protective immunoglobulins directed at P. aeruginosa cell surface antigens.  相似文献   

19.
An enzyme-linked immunosorbent assay for the measurement of antibodies directed against cell surface antigens of Vibrio cholerae (CSA ELISA) was developed. NaN3-killed whole cells of V. cholerae, adsorbed to polystyrene tubes, were used as immobilized antigens. The assay was capable of detecting antibodies directed against lipopolysaccharide and non-lipopolysaccharide surface antigens. In addition, the CSA ELISA was capable of detecting non-vibriocidal antibody. An antiserum raised in rabbits by immunization with live V. cholerae 1418 (Ogawa, El Tor) was capable of reacting with various heterologous strains of V. cholerae used as immobilized antigens. Therefore, common antigens shared by V. cholerae strains could be detected by using the CSA ELISA.  相似文献   

20.
An enzyme-linked immunosorbent assay for porcine parvovirus was developed for laboratory detection of parvovirus antigen in fetal tissues and compared with the fluorescent antibody and haemagglutination tests. The ELISA proved to be superior in terms of specificity, sensitivity, speed of performance and ease of interpretation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号