首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 98 毫秒
1.
Saphenous vein graft patency is frequently limited by degeneration. Experimental studies have indicated that rigid external support of venous grafts by a flexible, tubular nitinol mesh may improve graft patency. The study presented was part of a prospective, randomized, multicenter first-in-man trial investigating the safety and effectiveness of nitinol-supported venous grafts in coronary artery bypass graft (CABG) surgery. From our clinic, 25 subjects with multivessel coronary artery disease requiring saphenous vein graft CABG of the right coronary artery (RCA) and the circumflex artery were entered into the trial. Subjects were randomized to receive a mesh-supported graft on one of these arteries; the other vessel received an untreated vein graft. Graft patency was assessed by coronary angiography nine months after surgery. The implantation of mesh grafts was simple and safe. In 10 cases, a nitinol mesh-supported venous graft was anastomosed to the circumflex artery and in 15 cases to the RCA. All patients survived the observation period. A total of 72% of the patients underwent control coronary angiography. The patency rate of mesh-supported grafts was 27.8% nine months postoperatively. Conventional vein grafts showed an 85.7% patency, and arterial grafts had a 100% patency. No complications directly related to the implantation of mesh-supported grafts were observed. The promising experimental results of mesh-supported venous grafts could not be reproduced in the study presented. A critical item seems to be correct selection of nitinol mesh diameter, the anastomotic method and fixation of the mesh tube to the venous graft.  相似文献   

2.
This is a case report of 63-year-old man suffering from DeBakey III B acute dissection in association with thoracic aortic aneurysm. He had been following up for hypertension and thoracic aortic aneurysm. He was brought to the hospital by city ambulance complaining of sudden onset of severe back pain. Emergency operation was carried out. It revealed aneurysm of 90 mm in diameter located just distal to the aortic arch and an intimal tear or entry of the dissection located distal to the left subclavian artery. A low porosity Dacron graft was interposed between the distal aortic arch and middle portion of the thoracic descending aorta using inclusion technique. Systemic circulation was bypassing external iliac vein to artery using pump-oxygenator during aortic clamping. His postoperative course was uneventful. In review of the literature, association of the atherosclerotic aneurysm and acute dissection occurred approximately 5% in the cases of aortic dissection with increasing risk of aneurysmal rupture.  相似文献   

3.
BACKGROUND: Patients who have Stanford type A aortic dissection with impaired coronary arteries or who have aneurysms from the ascending aorta to the aortic arch with coronary artery disease need coronary artery bypass grafting (CABG) with tube graft replacement of the ascending aorta simultaneously. When vein grafts are used for CABG in these patients, the proximal anastomoses of vein grafts are attached to the prosthetic tube graft of the ascending aorta. However, the validity of proximal anastomoses of vein grafts to the prosthetic tube graft of the ascending aorta has not been confirmed. PATIENTS AND METHODS: We retrospectively analyzed patients who underwent venous coronary bypass grafting with prosthetic graft replacement of the ascending aorta. Between January 1984 and October 2002, 35 patients underwent CABG using saphenous vein grafts at the time of tube graft replacement of the ascending aorta, and the proximal anastomoses of the vein grafts were attached to the tube graft of the ascending aorta. Thirty-three venous bypass grafts were analyzed in 24 survivors. RESULTS: The postoperative catheterization showed only one early vein graft occlusion of 16 vein grafts anastomosed distally to the left anterior descending artery (LAD). All 14 venous grafts anastomosed to the right coronary artery (RCA) and 3 to the left circumflex artery (LCX) were patent. Therefore, the postoperative patency rate at discharge was 97.0% (32/33). Spiral computed tomography performed for long term follow-up revealed occlusion of two vein grafts (3.5 years and 9.7 years) anastomosed to the LAD. CONCLUSIONS: The patency rate of vein grafts anastomosed from prosthetic grafts of the ascending aorta to the native coronary arteries was similar to that of conventional CABG using saphenous vein grafts.  相似文献   

4.
Twenty-eight patients underwent renal vascular reconstruction for atherosclerotic renal vascular stenosis. Ten patients had therapeutic renal artery reconstruction for isolated renal artery stenosis causing severe hypertension, nine patients had therapeutic renal artery reconstruction for severe hypertension combined with simultaneous aortic reconstruction, and nine patients had prophylactic renal artery reconstruction for renal artery stenosis combined with simultaneous aortic reconstruction. Ninety percent of patients undergoing therapeutic renal revascularization procedures for hypertension were cured or improved. The 10 patients undergoing prophylactic renal artery reconstruction combined with aortic reconstruction had an average 72 percent reduction in the diameter of the vessel. Dacron side grafts sutured to the aortic graft were used for revascularization in each of the patients with prophylactic revascularization and was found to be an expedient means of reconstruction with good patency rates. No increased morbidity or mortality rate was noted in the prophylactic group. We believe that prophylactic revascularization should be carried out in patients with atherosclerotic high-grade stenosis of the renal arteries to prevent hypertension and preserve renal function.  相似文献   

5.
We describe a minimally invasive technique for complete aortic arch repair without cardiopulmonary bypass. A 77-year-old man with severe obstructive airways disease presented with aneurysmal disease of his aortic arch. Through a median sternotomy and the application of a side-biting clamp, the common trunk of a bifurcation Dacron graft was anastomosed to the ascending aorta. The limbs of the graft were anastomosed to the innominate and left common carotid arteries, respectively. The left subclavian artery was ligated. Two endoluminal stent grafts were deployed via a side arm in the Dacron graft, covering the whole arch. Completion angiography and transesophageal echocardiography revealed excellent seating of both stent grafts, with no endo-leaks. The patient had a rapid, uneventful post-operative recovery. Follow-up CT scanning revealed complete exclusion of the arch aneurysm.  相似文献   

6.
The purpose of our article is to describe a patient with severe hypertension and moderate renal insufficiency, unstable angina, and a 6 cm abdominal aortic aneurysm. A previous aortogram had demonstrated severe bilateral renal artery stenoses. Cardiac catheterization demonstrated severe coronary disease. After cardiac catheterization acute renal failure and pulmonary edema requiring dialysis developed in the patient. In addition, evidence of impending myocardial necrosis developed. Because of the critical nature of the myocardial and renal ischemia it was necessary to perform combined myocardial and renal revascularization rather than staged procedures. At the time of coronary artery bypass grafting, a vein graft was anastomosed to the right coronary artery vein graft and tunneled through the diaphragm into the abdomen to revascularize both renal arteries. After surgery renal function gradually improved, and no further dialysis was required. The abdominal aortic aneurysm was repaired at a subsequent operation. At 2-year follow-up all grafts remained patent. The serum creatinine is 1.2 mg/dl. Although most patients with combined coronary artery disease and renal artery disease can be treated with staged operations, our procedure may be of value in patients in whom staged procedure are not feasible and in whom the infrarenal aorta is severely diseased or aneurysmal.  相似文献   

7.
BACKGROUND/PURPOSE: Middle aortic syndrome is a rare condition that involves narrowing of the abdominal aorta and its visceral branches. The authors propose staged vascular repair to minimize renal ischemia and facilitate use of native arterial tissue for reconstruction. METHODS: Three adolescents (age 8(1/2), 12(1/2), 13(1/2)) presented with severe hypertension. Subsequent evaluation showed coarctation of the abdominal aorta extending above the celiac axis. All 3 patients had bilateral renal artery stenoses. There also were tight stenoses of the celiac or superior mesenteric arteries. In the first stage the right renal artery stenosis was relieved. In the youngest patient, this was accomplished by balloon angioplasty. However, in the other 2, right renal autotransplantation was performed to the right iliac vessels using end-to-side anastomoses of the renal artery and vein. Cold perfusion was used. The second stage was performed 2 to 5 months later via a thoracoabdominal approach in 2 patients. A Dacron tube graft was utilized from above the coarctation to the iliac bifurcation. The left renal arteries were detached and anastomosed end to side to the bypass graft. In 1 child there were actually 3 separate renal arteries that required reimplantation. In the youngest patient the aortic narrowing was relieved by a long Dacron patch aortoplasty and interposition of an internal iliac artery graft to the left renal artery. RESULTS: All 3 patients recovered well and returned to full activities. There was no measurable rise of BUN or serum creatinine postoperatively. Postoperative renal scans showed good renal perfusion bilaterally. Follow-up results 2 to 10 years later continue to show well functioning reconstructions. CONCLUSION: A staged approach is an effective reconstruction for children with middle aortic syndrome which minimizes risk to renal function.  相似文献   

8.
A successful surgical case of ruptured thoracoabdominal aortic aneurysm of Crawford type III was reported. The patient was a 40-year-old male suffering from cystic kidney, hypertension and dissecting aortic aneurysm. The operative procedure was implantation of a large Dacron graft between the ascending aorta and the common iliac arteries, with branches of small Dacron grafts anastomosed to the left common carotid, left subclavian, celiac, superior mesenteric and renal arteries, and exclusion of the aorta.  相似文献   

9.
2 ) angiography identified a saccular thoracic aortic aneurysm, right renal artery stenosis, left renal artery occlusion, an infrarenal aortic aneurysm, celiac artery, and inferior mesenteric artery (IMA) orificial stenoses. Via an anterior retroperitoneal approach, bilateral renal artery thromboendarterectomy, infrarenal aortic aneurysmectomy, and IMA reimplantation were performed. The patient's tortuous iliac arteries were straightened to permit future passage of a thoracic stent graft by mobilizing the aortic bifurcation and anastomosing it to a Dacron graft within 4 cm of the renal vessels. Two weeks later, a stent graft was placed via a femoral incision utilizing CO2 angiography, successfully excluding the saccular thoracic aneurysm. Recovery from both procedures was quick, with rapid return of renal function, and alleviation of the hypertension. At 8 months follow-up, his renal arteries and aorta are patent.  相似文献   

10.
A case of middle aortic syndrome which was thought to be the thoracoabdominal type of Takayasu's disease was successfully treated with the branched graft bypass. Patient was a 23 year-old woman with hypertension and abdominal pain. The preoperative angiography revealed aortic stenosis from the celiac axis to the left renal artery. The operative procedures were as follows; patient was positioned in supine with her left shoulder and arm raised. Eighth intercostal thoracotomy and midline laparotomy was performed with the thoracoabdominal incision. The branched graft was made previously with woven Dacron (phi 18 mm) and three EPTFEs (phi 8mm). The woven Dacron of the graft was used for the bypass from the descending thoracic aorta to the infrarenal abdominal aorta, and the branched EPTFEs of the graft were used for the bypasses to the common hepatic artery, the superior mesenteric artery and the right renal artery in this order. The bypasses were placed along the anatomical courses in the retroperitoneal space. Postoperatively, the blood pressure dropped and the abdominal pain disappeared. The plasma renin activity decreased and the renal function improved. Two months after operation the bypasses were patent by the angiography and now six months after operation she has returned to her social life healthily. The approach to the aorta and its abdominal branches by thoracotomy and laparotomy and bypass with the three branched graft was useful for middle aortic syndrome.  相似文献   

11.
BACKGROUND: The aim of this study was to evaluate the late results in adult patients who underwent surgery of the abdominal aorta as children. METHODS: During a 17-year period, eight children underwent surgery for lesions of the abdominal aorta. There were 6 boys and 2 girls, with an average age of 10 years. The presenting symptom that led to diagnosis of abdominal aortic lesions was hypertension in five cases and lower-limb claudication in three. The underlying disease was middle aortic syndrome in three cases, infrarenal aortic hypoplasia in two, infrarenal aortic aneurysm in two, and Takayasu's disease in one. Five children had associated renal artery lesions, including four with bilateral lesions and one with a unilateral lesion. Aortic bypass was used in all cases. A straight tube graft was placed between the distal descending thoracic or supraceliac aorta and the infrarenal aorta in six cases, and a bifurcated bypass was placed between the infrarenal aorta and the iliac arteries in two. Renal artery revascularization procedures (n = 9) included ex vivo repair with renal autotransplantation in five cases, direct reimplantation on the arch of Riolan in two, and direct reimplantation of the renal artery onto the aortic graft in two. RESULTS: One patient died on postoperative day 1. The remaining seven patients recovered uneventfully. Mean follow-up was 10.2 years. No patient was lost to follow-up. Further surgical intervention was required in three patients. The indications for additional surgery were fibrosis of a renal artery reimplanted onto the graft at 3 years, deterioration of the aortoaortic graft at 5 years, and false iliac aneurysm at 20 years. All seven patients had normal physical development. The average increase in height and weight were 28.5 cm and 26.2 kg, respectively. All patients had normal sexual function, and two are parents. All patients are currently asymptomatic. Short Form 36 scores for quality-of-life parameters were 78% to 83%. CONCLUSIONS: Late results of abdominal aortic surgery in children, in our experience, are encouraging. Quality of life in adulthood was excellent. Insofar as possible, correction should be deferred until the child is 8 to 10 years old so that a prosthesis of sufficient diameter can be used.  相似文献   

12.
To determine the role of Nd:YAG laser thermal angioplasty as the sole treatment for late stenoses of femorodistal artery bypass graft, the lasing effect of a larger size of hot-tip probe (3, 4, and 5 mm) was experimentally studied in vitro. For an adequate lasing effect, 30 watts of laser power output for 3 seconds was needed for the 3 mm probe, 40 watts for the 4 mm probe, and 50 watts for the 5 mm probe, respectively. Based on these results, we used Nd:YAG laser thermal angioplasty alone for 25 grafts, including 16 polytetrafluoroethylene (PTFE) grafts, eight saphenous vein grafts, and one externally supported (EXS) Dacron graft in which the stenotic lesions were detected by deterioration of the Doppler flow waveform pattern or a significant fall in the ankle/brachial pressure index (ABPI). Follow-up was from 3 to 24 months (average of 9 months) for PTFE grafts, from 5 to 21 months (average of 11 months) for saphenous vein grafts, and 13 months for the EXS Dacron graft following femorodistal artery reconstructions. Stenotic lesions were most common in the distal anastomotic sites: 11 PTFE grafts, three saphenous vein grafts, and one EXS Dacron graft. Among these, 13 grafts showed a type II flow waveform pattern at the time of surgery. Clinical success was achieved in 12 of the PTFE grafts (75%), in five of the vein grafts (62.5%), and in the single EXS Dacron graft. Four PTFE and three saphenous vein grafts failed subsequent to repeat intraoperative balloon angioplasty in three and graft extension in three and one graft interposition. Perforation occurred in only one vein graft. Continuing patency has now been maintained for up to 25 months after lasing. Nd:YAG laser thermal angioplasty using a 3 to 5 mm hot-tip probe is effective as the sole procedure for widening a stenotic lesion and improving patency after femorodistal artery reconstruction.  相似文献   

13.
Between 1986 and 1990, 11 patients with relative or absolute contraindications to standard infrarenal reconstructions underwent supraceliac aortofemoral bypass. The operation was performed through a left-flank incision extended into the eleventh intercostal space with retroperitoneal and extrapleural dissection. Indications included multiple failed infrarenal reconstructions in four patients, previous removal of infected aortofemoral bypass graft with failure of extra-anatomic bypass in five patients, prior para-aortic lymph node dissection and radiotherapy in one patient, and aortic aneurysmal disease proximal to the renal arteries in one patient. Bypass conduits included either a bifurcated Dacron graft or a tube graft to the left femoral artery with a femorofemoral cross-over graft; concomitant left renal artery reconstruction was performed in three patients. The mean supraceliac cross-clamp time was 24 minutes, and only one patient experienced transient postoperative acute tubular necrosis. There was no operative mortality. The graft limb patency was 95% after mean follow-up extending to 17 months (range: 5 months to 5 years). We conclude that the supraceliac aorta is a useful inflow source for aortofemoral reconstruction in difficult repeat cases. It can be approached easily without thoracotomy and avoids difficult infrarenal aortic dissection in a scarred field. The tunneling is easier than with descending thoracic aorta or ascending aorta inflow sources. In addition, this bypass is likely to be more durable than inflow reconstructions based on the axillary artery.  相似文献   

14.
BACKGROUND: We analyzed our 22 years of experience with extraanatomic bypass grafting for repair of aortic arch coarctation in adults. Results from early and midterm follow-up with clinical evaluation and magnetic resonance angiography are reported. METHODS: Between November 1979 and December 2001, 18 consecutive patients aged 18 to 61 years (mean, 31.8 +/- 13.3 years) underwent extraanatomic bypass grafting to repair coarctation of the aortic arch. Six patients (33.3%) had recoarctation after previous repair through a left thoracotomy, and 3 (16.7%) had associated cardiac diseases. The operative technique used in all patients was ascending aorta-to-descending thoracic aorta bypass with a polyethylene terephthalate fiber (Dacron) graft through a median sternotomy and posterior pericardial approach. RESULTS: Follow-up was completed in all patients, with a mean duration of 5.6 +/- 5.7 years (range, 12 months to 22 years). The follow-up interval exceeded 10 years in 5 patients. No neurologic complications, early or late mortality, late reoperations, or graft complications occurred. Six patients (33.3%) had mild hypertension. All patients were asymptomatic with patent Dacron grafts confirmed by echocardiography. Magnetic resonance angiography, performed in 15 (83.3%) patients, revealed that the Dacron grafts were still patent at a mean interval of 4.0 +/- 6.2 years (range, 5 days to 22 years) after repair. CONCLUSIONS: Extraanatomic ascending aorta-to-descending thoracic aorta bypass grafting for repair of aortic arch coarctation in adults is safe, with low morbidity and no mortality. The favorable midterm results indicate this technique is a safe and less invasive means of repairing aortic arch coarctation or recoarctation in adults.  相似文献   

15.
A knitted Dacron filamentous vascular prosthesis, 4 cm. long and 3.5 mm. in diameter, was used as an interposition graft between the aorta and right coronary artery in a 65-year-old woman on Oct. 25, 1974. The prosthesis was used to transplant the right coronary artery incident to removal of a saccular aneurysm if the ascending aorta. Concomitant mitral valve replacement and tricuspid annuloplaty were performed. The graft was demonstrated patent by angiograms 2 weeks, 7 months, and 16 months after the operation, and the patient continues to be clinically well 17 months postoperatively. The literature records the successful use of aorta-coronary Dacron prostheses in 2 other patents, both children with coronary anomalies. One of these grafts closed after a while: the second was demonstrated patent by angiograms 8 years after implantation. These cases demonstrate that prostheses can function in the aorta-coronary position, and the reports of saphenous vein failures indicate the need for a reasonable substitute when a patient's saphenous veins are absent or inadequate. In all 3 cases, the prostheses were quite short and were used as interposition grafts between the ascending aorta and the proximal end of the coronary artery. Our review did not reveal successful use of a synthetic graft for aorta-coronary bypass.  相似文献   

16.
We describe a 74-year-old male who underwent open stent repair for an infrarenal abdominal aortic aneurysm with a severely calcified aortic neck. The stent graft was constructed by covering a 50-mm long Gianturco Z stent (diameter: 20 mm) with a Dacron prosthesis (diameter: 20 mm). The stented Dacron graft was inserted into the calcified aortic neck, was then sutured to the trimmed aneurysmal wall, and was anastomosed to a bifurcated prosthesis. The distal ends of the bifurcated prosthesis were anastomosed to both common femoral arteries, and the terminal aorta was closed. The patient had an uneventful postoperative course. This procedure may be a feasible and safe way to repair infrarenal abdominal aortic aneurysm with a severely calcified aortic neck.  相似文献   

17.
A fatal aortoduodenal fistula occurred in a 72-year-old man who underwent a repair of an abdominal aortic aneurysm 16 years previously with a 20×10 mm bifurcated knitted Dacron graft. The aortic part of his bifurcated graft had dilated to 40 mm in diameter, with a discrepancy of 20 mm in the diameter between the graft and infrarenal aorta. The fourth portion of the duodenum adhered to the left side of the anastomosis, where the aortoenteric fistula had occurred. We believe that the graft dilatation was the cause of the anastomotic failure, although other factors such as atherosclerotic degeneration of the host aorta should also be considered. Knitted Dacron grafts that have been implanted for more than 10 years should therefore be monitored carefully because they have an inherent tendency to dilate, especially those manufactured before 1981.  相似文献   

18.
BACKGROUND: This study was performed to evaluate the safety and feasibility of endovascular stent graft placement in the treatment of descending thoracic aortic aneurysms. METHODS: Between November 1996 and February 1999, endovascular stent graft repair was used in 21 patients. There were 5 women and 16 men with a mean age of 67 years (range, 41 to 87 years). An atherosclerotic aneurysm with a diameter of more than 6 cm was the indication for intervention in 19 patients (90.5%). In 2 patients (9.5%), a localized aortic dissection with a diameter of more than 6 cm was treated. In 71.4% (15 of 21) of patients, multiple stents were necessary for aneurysm exclusion. To allow safe deployment of the stent graft, preliminary subclavian-carotid artery transposition was performed in 9 patients (42.9%). Vascular access was achieved through a small incision in the abdominal aorta (n = 6), an iliac artery (n = 8), or a femoral artery (n = 7). Talent and Prograft stent grafts were used. RESULTS: Successful deployment of the endovascular stent grafts was achieved in all patients. Two patients died postoperatively (mortality rate, 9.5%), 1 of aneurysmal rupture and the other of impaired perfusion of the celiac axis. Repeat stenting was done in 3 patients because of intraoperative leakage. CONCLUSIONS: Endovascular stent graft repair is a promising and less invasive alternative to exclude the aneurysm from blood flow. This technique allows treatment of patients who are unsuitable for conventional surgical procedures. An exact definition of inclusion criteria and technical development of stent grafts should contribute to further improvements in clinical results.  相似文献   

19.
Surgical Treatment of Ascending Aortic Pathology   总被引:3,自引:0,他引:3  
Among the first 10,200 valvular replacements performed in our unit, 288 complex repairs of the ascending aorta were done for various aortic pathology. Aneurysms of the ascending aorta were the most frequent; 53 supracoronary artery aneurysms with aortic valvular insufficiency were treated by the separate replacement of the aortic valve and the supracoronary ascending aorta; 206 annulo-aortic ectasia had total and combined replacement of the ascending aorta and the aortic valve with a personal modification of the Bentall's technique using an 8-mm diameter Dacron graft to perform the reimplantation of the coronary arteries on the composite aortic grafts. The operative mortality for the first 100 patients was 4% and for the entire 206 patients, 6%. Late mortality during a follow-up period ranging from 18 months to 8 years was 11%. The actuarial survival rate at 8 years is 75%; 25 patients restudied by angiography demonstrated satisfactory results with neither stenosis nor aneurysm on the coronary graft but a recurrent or persisting chronic distal aortic dissection in four patients. In 26 cases of aortic valvular endocarditis, large abscesses of the aortic annulus involved the aortic root. In 11, the aortic repair consisted of the insertion of a subcoronary valved conduit (two early deaths, two late deaths, one reoperation, seven good results--maximum follow-up of eight years). Twelve patients had a supracoronary valved conduit with four early deaths, one late death, and two reoperations; seven are alive and well, two to six years later. Three patients previously operated had a left ventricular abdominal aorta valved conduit; two of them are alive and well up to six years later. In three patients with iterative aortic paravalvular leak (recurring three or four times), ablation of the aortic insufficiency was obtained by interposition of a composite valved graft in the ascending aorta.  相似文献   

20.
PURPOSE: This study was undertaken to characterize the contemporary surgical treatment of pediatric renovascular hypertension. METHODS: A retrospective analysis was conducted of the clinical data of 97 consecutive pediatric patients (39 girls, 58 boys), aged from 3 months to 17 years, who underwent operation at the University of Michigan from 1963 to 2006. All but one patient had refractory hypertension not responsive to contemporary medical therapy. Developmental renal artery stenoses accounted for 80% of the renal artery disease, with inflammatory and other ill-defined stenoses encountered less frequently. Splanchnic arterial occlusive lesions affected 24% and abdominal aortic coarctations, 33%. RESULTS: Primary renal artery operations were undertaken 132 times. Procedures included resection beyond the stenosis and implantation into the aorta in 49, renal artery in 7, or superior mesenteric artery in 3; aortorenal and iliorenal bypasses with vein or iliac artery grafts in 40; focal arterioplasty in 10; resection with reanastomosis in 4; operative dilation in 4; splenorenal bypass in 2; and primary nephrectomy in 13 when arterial reconstructions proved impossible. Bilateral renal operations were done in 34 children, and 17 underwent celiac or superior mesenteric arterial reconstructions, including 15 at the time of the renal operation. Thirty patients underwent abdominal aortic reconstructions with patch aortoplasty (n = 19) or thoracoabdominal bypass (n = 11). Twenty-five of the aortic procedures were performed coincidently with the renal operations. Thirty secondary renal artery procedures were done in 19 patients, including nine nephrectomies. Hypertension was cured in 68 children (70%), improved in 26 (27%), and was unchanged in three (3%). Follow-up averaged 4.2 years. No patients required dialysis, and there were no operative deaths. CONCLUSION: Contemporary surgical treatment of pediatric renovascular hypertension emphasizes direct aortic implantation of the normal renal artery beyond its stenosis and single-staged concomitant splanchnic and aortic reconstructions when necessary. Benefits accompany carefully executed operative procedures in 97% of these children.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号