首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Background Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.  相似文献   

2.
PURPOSE: To retrospectively determine the diagnostic yield of double-contrast barium enema examinations performed for colorectal cancer screening of neoplasms 1 cm or larger or advanced neoplastic lesions of any size in average-risk adults older than 50 years. MATERIALS AND METHODS: The Institutional Review Board at the affiliated Veterans Affairs Medical Center approved this HIPAA-compliant study protocol and did not require informed consent from patients. Computerized databases revealed 276 double-contrast barium enema examinations performed for colorectal cancer screening in average-risk adults older than 50 years. Radiographic and pathologic reports were reviewed to determine the number of patients who had polypoid lesions 1 cm or larger, polyps smaller than 1 cm, or advanced neoplastic lesions of any size. Forty-five (16.3%) of the 276 patients underwent follow-up sigmoidoscopy or colonoscopy. Medical, endoscopic, and pathologic records were reviewed and compared with radiographic findings. RESULTS: The results of double-contrast barium enema examination revealed 74 (26.8%) of 276 patients with 104 polypoid lesions in the colon, including 32 patients (11.6%) with 41 polypoid lesions 1 cm or larger, 15 patients (5.4%) with 19 polyps 6-9 mm, and 27 patients (9.8%) with 44 polyps 5 mm or smaller. Endoscopy was performed in 24 (75%) of 32 patients, the results of which confirmed 23 (72%) of 32 radiographically diagnosed lesions 1 cm or larger in 16 (67%) of 24 patients. In two of these individuals, the polyps were hyperplastic. The remaining 14 patients had a total of 21 neoplastic lesions 1 cm or larger, including 11 tubular adenomas, seven tubulovillous adenomas, one villous adenoma with marked dysplasia, and two cancers. The diagnostic yield of screening double-contrast barium enema examination was 5.1% (14 of 276 patients) for neoplastic lesions 1 cm or larger and 6.2% (17 of 276 patients) for advanced neoplastic lesions of any size. CONCLUSION: Double-contrast barium enema examinations performed in average-risk adults older than 50 years have a diagnostic yield of 5.1% for neoplastic lesions 1 cm or larger and 6.2% for advanced neoplastic lesions, regardless of size.  相似文献   

3.
PURPOSE: To prospectively investigate with computed tomographic (CT) colonography the prevalence and size distribution of nonadenomatous polyps in asymptomatic adults and to compare the detection rates of adenomatous and nonadenomatous polyps. MATERIALS AND METHODS: A total of 1233 asymptomatic adults (mean age, 57.8 years; 505 women, 728 men) underwent same-day CT colonography and optical colonoscopy procedures. CT colonoscopy studies were interpreted prospectively with a primary three-dimensional approach immediately before optical colonoscopy. Statistical analysis was performed with the chi(2) test. Size, prevalence, and by-polyp detection differences were compared between adenomatous and nonadenomatous polyps. RESULTS: Seven hundred fifty-six (57.7%) colorectal polyps identified at optical colonoscopy in 410 (33.3%) patients were nonadenomatous; of these lesions, 622 (82.3%) were diminutive (相似文献   

4.
Spiral CT pneumocolon: applications, status and limitations   总被引:4,自引:0,他引:4  
CT pneumocolon is a promising new technique in the diagnosis and management of colon pathology. CT pneumocolon can detect (sensitivity >95%) and stage (accuracy 79%) colorectal cancer and is very accurate in the differentiation of malignant from benign colonic pathologies. It has excellent detection rates for polyps >10 mm in diameter. Several studies using 3D virtual colonoscopy have already proven its high sensitivity and specificity in polyp detection making this technique robust as a screening tool. The combined results for virtual colonoscopy, from all centres, show a sensitivity of >85% in the detection of polyps 10 mm or greater in size, 70-80% for 5-9 mm polyps and an overall specificity of 90%. CT pneumocolon is a safe, non-invasive and cost-effective method for detecting colonic carcinomas and adenomas and correctly identifying which patients need further colonoscopy. The technique is quick, well tolerated and non-operator dependent. It can also image the proximal colon when distal stenoses prevent endoscopic and barium examination. CT pneumocolon is able to identify the features and complications of inflammatory bowel disease. Further research is warranted to fully assess its impact in terms of a screening tool, acceptability, availability and cost benefit.  相似文献   

5.
Significance of missed polyps at CT colonography   总被引:7,自引:0,他引:7  
OBJECTIVE: Our purpose was to determine the clinical significance of polyps missed on CT colonography using histologic analysis and the natural history of colorectal polyps and to propose guidelines for follow-up colon surveillance based on CT colonographic findings. SUBJECTS AND METHODS. One hundred eighty-six men (age range, 40-87 years; mean, 62.3 years) underwent CT colonography immediately before conventional colonoscopy. All polyps detected on CT colonography were measured and imaged, and their segmental location was documented. All polyps detected on colonoscopy were measured, photographed, biopsied, and histologically analyzed. Results of CT colonography and conventional colonoscopy were compared with the final pathology reports. Conventional colonoscopy was used as the gold standard unless CT colonography showed a lesion measuring 10 mm or more that was not detected on conventional colonoscopy and had characteristics of a polyp. In these cases, follow-up conventional colonoscopy was offered. RESULTS: One hundred ninety-one polyps were detected on conventional colonoscopy. CT colonography prospectively detected 53 polyps. Histologic analysis of the polyps not detected on CT colonography showed that of those 5 mm or smaller, 58.1% were not adenomas, and of those measuring 6-9 mm, 42.8% were not adenomas. Both missed polyps at CT colonography of 10 mm or more were adenomas. Of the 22 polyps measuring 10 mm or more, three were not detected on conventional colonoscopy. Of these three, CT colonography showed a lesion having characteristics of a polyp, follow-up endoscopy confirmed the presence of the lesion, and histologic analysis showed a villous adenoma, a tubulovillous adenoma, and a tubular adenoma. CONCLUSION: If CT colonography shows no abnormality, follow-up screening in 5 years is recommended. If CT colonography detects a lesion smaller than 5 mm, follow-up imaging in 3-5 years is recommended. If CT colonography detects a lesion measuring 6 mm or more, endoscopy and polypectomy should be offered unless contraindicated.  相似文献   

6.
OBJECTIVE: We sought to evaluate the effect of interpreter confidence on the likelihood that a lesion detected on CT colonography (CTC) will correspond to a matched polyp seen on optical colonoscopy. SUBJECTS AND METHODS: Same-day CTC and optical colonoscopy were performed on 1,339 asymptomatic adults. A standard matching algorithm for polyp size and location was used. For each potential polyp detected on CTC, the level of diagnostic confidence was prospectively rated on a 3-point scale (1, least certain; 2, intermediate; and 3, most certain). RESULTS: For CTC-detected lesions 6 mm or larger, diagnostic confidence levels of 1, 2, and 3 corresponded to matched polyps on optical colonoscopy in 33.3% (45/135), 50.0% (103/206), and 66.8% (157/235) of cases, respectively (p < 0.01). Similar trends were present for categories of lesions that measured 6-7 mm, 8-9 mm, and 10 mm or larger, rising to a match rate of 82.1% (55/67) for lesions 10 mm or larger that were diagnosed with a level-3 confidence rating. The likelihood that a matched polyp was adenomatous increased with greater levels of diagnostic confidence. Of note, level-3 confidence for lesions measuring 8-9 mm on CTC more often yielded a matching neoplasm on optical colonoscopy than level-1 or level-2 confidence for lesions measuring 10 mm or larger (60.3% [35/58] vs 20.8% [10/48]; p < 0.0001). CONCLUSION: Greater diagnostic confidence for an individual lesion detected on CTC correlates with a significantly increased likelihood that a matching polyp will be found on optical colonoscopy and that this matched polyp will be neoplastic. Although polyp size represents the primary criterion for CTC screening algorithms, this data could help guide the decision to opt for noninvasive CTC surveillance versus optical colonoscopy for polypectomy.  相似文献   

7.
18F-FDG PET detection of colonic adenomas.   总被引:14,自引:0,他引:14  
The adenomatous polyp of the colon is clinically important as a precursor of colonic cancer. The aim of this preliminary study was to evaluate the potential usefulness of (18)F-FDG PET for detecting adenomatous polyps of the colon. METHODS: We performed a retrospective study of 110 subjects who underwent both PET study and total colonoscopy. On nonattenuation-corrected PET images, focal distinct FDG accumulation along the large intestine was considered a positive finding, and the PET results were compared with colonoscopic findings. Histology and adenoma size were determined by polypectomy. RESULTS: Fifty-nine adenomatous polyps, 5-30 mm in size, were found in 30 subjects by total colonoscopy. PET findings were positive for 14 of the 59 adenomas (24%). The positivity rate for PET images rose with the increase in size of the adenomas; it was 90% in adenomas (9/10) that were > or =13 mm. The overall false-positive rate was 5.5% (6/110 subjects). CONCLUSION: Increased glucose metabolism is observed in colonic adenomas, and detectability with PET increases with the increase in adenoma size. Adenomas are premalignant lesions, and it is important to realize that colonic adenomas may be found incidentally during an FDG PET study.  相似文献   

8.
PURPOSE: To improve the sensitivity of computed tomography (CT) colonography in the detection of polyps by comparing the 3D reconstruction tool "colon dissection" and endoluminal view (virtual colonoscopy) with axial 2D reconstructions. MATERIAL AND METHODS: Forty-eight patients (22 M, 26 F, mean age 57 +/- 21) were studied after intra-anal air insufflation in the supine and prone positions using a 16-slice helical CT (16 x 0.625 mm, pitch 1.7; detector rotation time 0.5 s; 160 mAs und 120 kV) and conventional colonoscopy. Two radiologists blinded to the results of the conventional colonoscopy analyzed the 3D reconstruction in virtual-endoscopy mode, in colon-dissection mode, and axial 2D slices. RESULTS: Conventional colonoscopy revealed a total of 35 polyps in 15 patients; 33 polyps were disclosed by CT methods. Sensitivity and specificity for detecting colon polyps were 94% and 94%, respectively, when using the "colon dissection", 89% and 94% when using "virtual endoscopy", and 62% and 100% when using axial 2D reconstruction. Sensitivity in relation to the diameter of colon polyps with "colon dissection", "virtual colonoscopy", and axial 2D-slices was: polyps with a diameter >5.0 mm, 100%, 100%, and 71%, respectively; polyps with a diameter of between 3 and 4.9 mm, 92%, 85%, and 46%; and polyps with a diameter < 3 mm, 89%, 78%, and 56%. The difference between "virtual endoscopy" and "colon dissection" in diagnosing polyps up to 4.9 mm in diameter was statistically significant. CONCLUSION: 3D reconstruction software "colon dissection" improves sensitivity of CT colonography compared with the endoluminal view.  相似文献   

9.
OBJECTIVE: The objective of this phantom study was to determine the performance of MDCT colonography for the detection of small polyps under ideal imaging conditions and to determine the added value of 3D imaging when used as an adjunct to 2D imaging. MATERIALS AND METHODS: Thirty-six polypoid and 39 flat polyps (44 lesions, 2-5 mm; 31 lesions, 6-8 mm) were placed in three explanted segments of a thoroughly cleaned porcine colon (overall length, 4.5 m) that was distended with air and submerged in a water phantom. MDCT data sets with 4 x 1 mm collimation and 6-mm table feed were reconstructed every 0.7 mm with 1.25-mm effective slice width. The data were reviewed by three radiologists using 2D images in all three projections and with 3D volume-rendered images available as an adjunct to the 2D images. RESULTS: Additional 3D as a problem-solving tool significantly increased the overall sensitivity (96% vs 90%), decreased the total number of false-positive calls (n = 9 vs n = 5), and increased the diagnostic confidence level (p < 0.03) compared with 2D images alone. Small polyps less than or equal to 5 mm (89% vs 95%, p = 0.004) and flat polyps (82% vs 94%, p = 0.001) especially benefited from 3D. Sensitivity was generally higher for polypoid than for flat polyps (99% vs 94%, p = 0.041). CONCLUSION: Under phantom conditions, simulating an ideal clinical setup, MDCT colonography is not limited by spatial resolution and detects polyps less than or equal to 5 mm in size with high sensitivity and specificity. Additional 3D image tools improve diagnostic accuracy and reviewer confidence, especially for the detection of flat and small polyps.  相似文献   

10.
PURPOSE: To examine: (1) the feasibility of PET/CT colonography (PET/CTc) in patients with colorectal polyps; (2) the impact of metabolic information on CTc interpretation and, conversely, the impact of morphological information on PET characterisation of focal colorectal uptake. METHODS: Ten patients with colorectal polyps underwent PET/CTc, followed within 3 h by therapeutic conventional colonoscopy (CC). A radiologist and a nuclear medicine physician analysed the PET/CTc images. The agreement of morphological and metabolic information in the colon and rectum was evaluated. The sensitivity and specificity of PET, CT and PET/CT were calculated for colorectal polyps. RESULTS: Seventeen polypoid lesions were identified at CC: six< or =5 mm, six between 6 and 9 mm, and five > or =10 mm (four hyperplastic polyps, 11 tubular adenomas, one adenocarcinoma and one submucosal lipoma). A total of 20 scans (supine and prone) were performed in the ten patients: the agreement of morphological and metabolic information was excellent in 17 scans, good in two and moderate in one. PET/CTc showed a sensitivity of 91% for lesions > or =6 mm and a specificity of 100%. The metabolic information did not disclose any further polyps missed on CTc. The morphological information permitted correct classification of all eight instances of focal radiotracer uptake. CONCLUSION: PET/CTc is a feasible study. Adding a colonographic protocol to PET/CT images seems to allow correct characterisation of all cases of colorectal focal radiotracer uptake. The metabolic information does not seem to increase the accuracy of CTc.  相似文献   

11.
Virtual colonoscopy--chances for a screening procedure?   总被引:1,自引:0,他引:1  
Rust GF  Reiser M 《Der Radiologe》2002,42(8):617-621
In principle, virtual colonoscopy is capable to be used as method for early detection of colorectal cancer (CRC), even if the accuracy of the method and radiation exposure are matters discussion in the radiological community. Virtual colonoscopy is able to detect any pathology which is relevant for early detection of CRC especially when using multislice CT, but also with single slice CT. The diagnosis of small lesions, less than 7 mm in diameter (polyps and flat lesions) is still problematic as it is in conventional colonoscopy. The exposure to x-rays in asymptomatic patients, without any increased risk of developing cancer is highly problematic and should be reduced to a minimum. Using special post processing filters on the volume dataset it can be shown that a tube current of 20 mAs is sufficient without any loss in accuracy. Measurements on the Alderson-phantom showed, that an effective dose exposure of 1.2 mSv is obtained using these reduced mAs values. It has to be differentiated between virtual colonoscopy for early detection of polyps and CRC in individual patients or as a screening examination of a large population. Virtual colonoscopy as a screening examination necessitates reduction of radiation dose, a high degree of automatization in 3D reconstructions as well as the assessment of the entire mucosa. High risk patients, whom refuse fibreoptic colonoscopy should undergo virtual colonoscopy. Virtual colonoscopy has a good chance to become an accepted tool for general screening, if efficient dose reduction, complete visualization of the colon mucosa and automatization of the post processing procedures can be achieved.  相似文献   

12.
PURPOSE: To compare thin-section multi-detector row computed tomographic (CT) colonography with conventional colonoscopy in the evaluation of colorectal polyps and cancer in asymptomatic average-risk patients. MATERIALS AND METHODS: Sixty-eight asymptomatic men (age > 50 years) scheduled to undergo screening colonoscopy were enrolled in this study. CT colonography was followed by conventional colonoscopy, performed on the same day. Supine and prone CT colonography were performed after colonic insufflation with room air. A gastroenterologist measured all polyps, which were categorized as 1-5, 6-9, or over 10 mm. Biopsy and histologic evaluation were performed of all polyps. CT colonography and colonoscopy results were compared for location, size, and morphology of detected lesions. Point estimates and 95% CIs were provided for specificity and sensitivity of CT by using results at conventional colonoscopy as the reference standard. RESULTS: At colonoscopy, 98 polyps were identified in 39 patients; 21 (21.4%) of 98 were detected at CT colonography. Sensitivity was 11.5% (nine of 78) for polyps 1-5 mm, 52.9% (nine of 17) for polyps 6-9 mm, and 100% (three of three) for polyps over 10 mm. Results at colonoscopy were normal in 29 (42.6%) of 68 patients; at CT colonography, results were correctly identified as normal in 26 of these 29 patients. In one of these patients, a lesion larger than 10 mm was detected at CT colonography. The per-patient specificity of CT was 89.7% (26 of 29; 95% CI: 72.7%, 97.8%). The mean time for CT image interpretation was 9 minutes. CONCLUSION: In patients at average risk for colorectal cancer, CT colonography is a sensitive and specific screening test for detecting polyps 10 mm or larger; the sensitivity for detecting smaller polyps is decreased. Examination findings can be interpreted in a clinically feasible amount of time.  相似文献   

13.
The aim of this prospective trial was to evaluate sensitivity and specificity of bright lumen magnetic resonance colonography (MRC) in comparison with conventional colonoscopy (CC). A total of 120 consecutive patients with clinical indications for CC were prospectively examined using MRC (1.5 Tesla) which was then followed by CC. Prior to MRC, the cleansed colon was filled with a gadolinium-water solution. A 3D GRE sequence was performed with the patient in the prone and supine position, each acquired during one breathhold period. After division of the colon into five segments, interactive data analysis was carried out using three-dimensional post-processing, including a virtual intraluminal view. The results of CC served as a reference standard. In all patients MRC was performed successfully and no complications occurred. Image quality was diagnostic in 92% (574/620 colonic segments). On a per-patient basis, the results of MRC were as follows: sensitivity 84% (95% CI 71.7-92.3%), specificity 97% (95% CI 89.0-99.6%). Five flat adenomas and 6/16 small polyps (< or =5 mm) were not identified by MRC. MRC offers high sensitivity and excellent specificity rates in patients with clinical indications for CC. Improved MRC techniques are needed to detect small polyps and flat adenomas.  相似文献   

14.
The purpose of this study was to compare sensitivity, specificity, and postprocessing time of a colon dissection approach to regular 3D-endoluminal workup of computed tomography (CT) colonography for the detection of polypoid lesions. Twenty-one patients who had received conventional colonoscopy after CT colonography were selected; 18 patients had either colon polyps or colon cancer and three had no findings. CT colonography was performed using a 4-channel multi-detector-row (MDR) CT in ten cases and a 16-channel MDR-CT in 11 cases. A blinded reader retrospectively evaluated all colonographies using both viewing methods in a randomized order. Thirty-seven polyps were identified by optical colonoscopy. An overall per-lesion sensitivity of 47.1% for lesions smaller than 5 mm, 56.3% for lesions between 5 mm and 10 mm, and 75.0% for lesion larger than 10 mm was calculated using the colon dissection approach. This compared to an overall per-lesion sensitivity of 35.3% (<5 mm), 81.5% (5–10 mm), and 100.0% (>10 mm) using the endoluminal view. The average time consumption for CT colonography evaluation with the colon dissection software was 10 min versus 38 min using the endoluminal view. A colon dissection approach may provide a significant time advantage for evaluation of CT colonography while obtaining a high sensitivity. It is especially superior in the detection of lesions smaller than 5 mm.  相似文献   

15.
PURPOSE: To evaluate our experience in the 1st year of computed tomographic (CT) colonography screening since the initiation of local third-party payer coverage. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, and informed consent was waived. Over a 1-year period that ended on April 27, 2005, 1110 consecutive adults (585 women, 525 men; mean age, 58.1 years) underwent primary CT colonography screening. More than 99% were covered by managed care agreements. CT colonographic interpretation was performed with primary three-dimensional polyp detection, and the final results were issued within 2 hours. Patients with large (> or =10-mm) polyps were referred for same-day optical colonoscopy, and patients with medium-sized (6-9-mm) lesions had the option of immediate optical colonoscopy or short-term CT colonography surveillance. RESULTS: Large colorectal polyps were identified at CT colonography in 43 (3.9%) of 1110 patients. Medium-sized lesions were identified in 77 (6.9%) patients, 31 (40%) of whom chose optical colonoscopy and 46 (60%) of whom chose CT colonography surveillance. Concordant lesions were identified in 65 of 71 patients who underwent subsequent optical colonoscopy (positive predictive value, 91.5%). Sixty-one (86%) of 71 optical colonoscopic procedures were performed on the same day as CT colonography, thereby avoiding the need for repeat bowel preparation. The actual endoscopic referral rate for positive findings at CT colonography was 6.4% (71 of 1110 patients). The demand for CT colonography screening from primary care physicians and their patients increased throughout the study period. CONCLUSION: As a primary colorectal screening tool, CT colonography covered by third-party payers has an acceptably low endoscopic referral rate and a high concordance of positive findings at optical colonoscopy.  相似文献   

16.
Consensus on current clinical practice of virtual colonoscopy   总被引:6,自引:0,他引:6  
OBJECTIVE: The purpose of our study was to determine the current opinions regarding the performance, interpretation, reporting, and clinical role of virtual colonoscopy among a group of selected experts to develop a consensus statement. MATERIALS AND METHODS: A questionnaire was sent to 33 selected experts in virtual colonoscopy. Responses were tabulated and results were used to develop a consensus statement. The results of the questionnaire and consensus statement were sent to respondents for comment and approval. RESULTS: Thirty-one (93.9%) of 33 surveys were returned. Eighty-seven percent (27/31) of respondents believe virtual colonoscopy is a credible screening method. Oral sodium phosphate solution is the laxative preferred by more than 66% (18/27), whereas 62% (13/21) do not believe fecal tagging is necessary. All respondents (25/25) think that both prone and supine imaging is required, with most (81%, 21/26) believing IV contrast material is not necessary. The routine use of spasmolytics is suggested by only 15% (4/26). The largest acceptable slice thickness of 3 mm is agreed on by 88% (22/25). All respondents believe screening virtual colonoscopy should be performed at a lower dose per slice than conventional CT. Most (80%, 20/25) believe the optimum method of interpreting virtual colonoscopy should be primary axial review, with 3D used for problem solving. All but one respondent (96%, 26/27) agree there is a threshold size below which polyps are not clinically important. When reporting virtual colonoscopy results, 59% (16/27) believe polyps less than 4 mm need not be reported. CONCLUSION: A consensus is developing among experts as to the appropriate manner in which virtual colonoscopy should be performed, interpreted, and reported.  相似文献   

17.
CT colonography in 546 patients with incomplete colonoscopy   总被引:8,自引:0,他引:8  
PURPOSE: To retrospectively evaluate the positive predictive value (PPV) of computed tomographic (CT) colonography performed in patients who were referred for further examination after incomplete colonoscopy. MATERIALS AND METHODS: This HIPAA-compliant retrospective study was approved by the institutional review board; informed consent was waived. We identified 546 consecutive patients (mean age, 64.1 years; 401 [73.4%] women) who underwent CT colonography after incomplete colonoscopy between November 1999 and December 2002. A retrospective chart review was performed if CT colonography depicted endoscopically nonvisualized lesions 6 mm or greater in diameter. Repeat colonoscopy rate, endoluminal findings, and PPV of CT colonography were determined. Subsequent colonoscopic findings were used as the reference standard. RESULTS: In 72 (13.2%) patients, CT colonography depicted 88 endoscopically nonvisualized lesions 6 mm or greater. Of 11 patients reported to have 12 masses (> or =20 mm), at subsequent colonoscopy, one patient had no mass. Eighteen patients had 23 large (10-19-mm) polyps that they were suspected of having, and 47 patients had 53 medium (6-9-mm) polyps that they were suspected of having. At a median follow-up of 31 months (range, 6-42 months), 45 (63%) of 72 patients underwent follow-up colonoscopy because of their CT colonographic findings. Rates of repeat colonoscopy for masses, large polyps, and medium polyps were 100%, 94%, and 45%, respectively. Per-patient and per-lesion PPVs of CT colonography for masses, large polyps, and medium polyps were 90.9% and 91.7%, 64.7% and 70%, and 33.3% and 30.4%, respectively. CONCLUSION: CT colonography has the potential to become an accepted technique for evaluation of the nonvisualized part of the colon after incomplete colonoscopy, and it can increase the diagnostic yield of masses and clinically important polyps in this part of the colon.  相似文献   

18.
OBJECTIVE: To investigate the diagnostic value of CT colonography for the detection of colorectal polyps. MATERIALS AND METHODS: From December 2004 to December 2005, 399 patients underwent CT colonography and follow-up conventional colonoscopy. We excluded cases of advanced colorectal cancer. We retrospectively analyzed the CT colonography findings and follow-up conventional colonoscopy findings of 113 patients who had polyps more than 6 mm in diameter. Radiologists using 3D and 2D computer generated displays interpreted the CT colonography images. The colonoscopists were aware of the CT colonography findings before the procedure. RESULTS: CT colonography detected 132 polyps in 107 of the 113 patients and conventional colonoscopy detected 114 colorectal polyps more than 6 mm in diameter in 87 of the 113 patients. The sensitivity of CT colonography analyzed per polyp was 91% (41/45) for polyps more than 10 mm in diameter and 89% (101/114) for polyps more than 6 mm in diameter. Thirteen polyps were missed by CT colonography and were detected on follow-up conventional colonoscopy. CONCLUSION: CT colonography is a sensitive diagnostic tool for the detection of colorectal polyps and adequate bowel preparation, optimal bowel distention and clinical experience are needed to reduce the rate of missing appropriate lesions.  相似文献   

19.
OBJECTIVE: We sought to investigate the feasibility of 3-dimensional ultrasound (3D US)-based virtual cystoscopy in experimentally designed bladder phantoms using pig bladders. MATERIALS AND METHODS: Ten bladder phantoms with simulated polypoid tumors of different sizes were constructed to provide 3D US-based virtual cystoscopic images. The simulated polypoid tumors were divided by their location into 2 groups: group 1 included the polyps on the anterior and posterior walls, and group 2 included those on the remaining 4 walls. Two genitourinary radiologists independently interpreted the virtual cystoscopic images, with a consensus reached for cases with discrepant results. RESULTS: In a consensus reading, 3D US-based virtual cystoscopy detected 44 (91.7%) of 48 polypoid lesions. All lesions (n = 4) with false-negative results were 5 mm or smaller in diameter, and so the detection rate was 81.8% (18/22) for lesions 5 mm or smaller whereas it was 100% (26/26) for lesions larger than 5 mm. The detection rate for group 1 (93.8%) was not significantly different from that for group 2 (90.6%; P = 1.000). There were 7 false-positive lesions. Of these, 5 lesions were seen in group 1, and reverberation artifacts were the most common source of these errors (n = 4). Blind areas were present in 19 (31.7%) of 60 virtual cystoscopic images and were seen only in group 2. The differences in the false-positive rate and the incidence of blind area were statistically significant between both groups (P = 0.036, P = 0.00008, respectively). CONCLUSION: 3D US-based virtual cystoscopy may have diagnostic potential in the detection of polypoid bladder tumors.  相似文献   

20.
INTRODUCTION: Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. MATERIAL AND METHODS: We examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. RESULTS: Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. There were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps > or = 1 cm. CONCLUSIONS: Virtual colonoscopy is an imaging modality with good diagnostic yield, well tolerated by patients and with great potentials for further development. We suggest that the examination be performed in symptomatic patients who cannot undergo total colonoscopy or refuse the other imaging modalities. Further studies are warranted in larger series of patients, possibly introducing it in screening programs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号