首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
三维增强磁共振血管造影(three dimensiona contrast-enhanced MR angiography,3DCE-MRA)利用对比剂造成血管组织间的对比进行血管成像,因其具有简便易行、图像清晰的特点在临床上应用越来越广。在椎动脉3DCE-MRA  相似文献   

2.
三维增强磁共振血管造影(three dimension con:rast enhanced MR angiography.3D CE-MRA)利用对比剂造成血管组织间的对比进行血管成像.因其具有简便易行、图像清晰的特点在临床上应用越来越广。在椎动脉3DCE-MRA中,为了捕捉到椎动脉显影最佳时相并减少静脉重叠,  相似文献   

3.
目的 通过与DSA对照,探讨透视触发3DCE MRA在颈部动脉狭窄诊断中应用价值。方法 回顾性分析60例经DSA确诊的颈部动脉狭窄患者的3DCE MRA影像资料,以血管狭窄部位、数目及程度等作为分析指标,由两位放射科医师进行比较分析。结果 60例患者中3DCE MRA共发现狭窄血管126处,其中轻度49处,中度41处,重度29处,闭塞7处。DSA诊断相应部位血管狭窄124处,其中轻度狭窄49处、中度狭窄40处、重度狭窄29处、闭塞6处;3DCE MRA与DSA对颈部动脉狭窄的诊断结果的一致性较好。结论 透视触发3DCE MRA能够清晰显示颈部动脉狭窄性病变情况,具有广泛的临床应用价值,可基本替代诊断性DSA。  相似文献   

4.
MRI透视触发造影剂团追踪技术在小肝癌增强扫描中的应用   总被引:2,自引:1,他引:1  
目的 探讨透视触发造影剂团追踪 (FTB)技术在小肝癌 (SHCC)多期扫描中的临床应用价值。方法  2 0例临床及其它检查诊断或可疑小肝癌的患者。分成 2组 ,对照组 1 0例按常规方法进行增强扫描 ,实验组 1 0例增强扫描前采用FTB技术 ,监测出主动脉及心脏内造影剂浓度从无到有的变化过程图后 ,再接着进行增强扫描。结果 对照组仅 3例获得较好动脉期 ,确诊小肝癌 3例 ;实验组所有病例均获得最佳动脉期 ,检出小肝癌 7例 ,1 0例确诊的小肝癌均得到手术及病理的证实。结论 FTB技术的应用可提高小肝癌的检出率  相似文献   

5.
目的 探讨3D动态增强磁共振血管造影在腹部血管病变中的检查技术及临床应用。方法 搜策18例腹部血管的3DDCE—MRA检查资料,对其影像表现进行总结分析。结果 18例3DDCE—MRA血管均显示满意,表现正常者4例,动脉硬化2例,腹主动脉瘤1例,门脉高压6例,门静脉瘤栓5例,其中2例显示门静脉海绵样变性。结论 3DDCE—MR~无损伤,成像速度快,对腹部大血管的病变能清楚显示,有重要的临床应用价值。  相似文献   

6.
目的探讨透视跟踪技术三维动态增强磁共振血管造影(3DCE-MRA)在下肢动脉病变中的临床应用价值。方法在161例疑有下肢血管病变做下肢3 D CE-MRA的患者中随机抽取50例,对其成像表现及均值曲线(mean curve)进行回顾性分析。结果当靶血管感兴趣区(腹主动脉腹腔干水平)对比剂信号强度mean值上升到40~60范围内开始触发扫描,也就是感兴趣区有造影剂显影第4~6s触发扫描能准确地观察3段(下腹及盆腔、大腿、小腿)动脉血管,3段血管充盈饱满并且静脉干扰少。结论透视跟踪技术3 DCE-MRA能较好地显示下肢动脉病变的范围和程度,具有操作简便、快捷、节省造影剂用量等优点,而触发扫描时间点的正确选择更有利于动脉病变的检出,可为临床诊断提供更准确的信息。  相似文献   

7.
CT血管成像技术在肾动脉的应用   总被引:3,自引:0,他引:3  
多层螺旋(MS)CT血管成像(multislice spiral CT angiography,MSCAT)即CT扫描和三维(3D)重建技术的综合利用。是目前MSCT成像的一项新技术。我院自2001年开始使用多MSCT机,颇有收益。本文旨在探讨MSCTA技术在肾动脉疾病中的应用价值和方法。  相似文献   

8.
【摘要】 目的:探讨3D动脉自旋标记(ASL)技术全脑MRI对儿童脑血管病变的诊断价值。方法:搜集我院2014年5月-2015年10月经DSA或手术证实的16例脑血管病变患儿的病例资料。其中烟雾病9例,脑血管畸形7例。所有患儿均行3.0T MR T1WI、T2WI、T2-FLAIR、DWI、MRA及3D-ASL脑灌注成像检查,对3D-ASL原始图像采用Functool软件进行后处理,测量2组患者病变部位的脑血流量(CBF),计算病变与对侧的相对CBF(rCBF)并进行统计学分析。结果:9例烟雾病患儿中8例病变部位表现为低灌注(rCBF=0.74±0.21),其中3例常规MRI未发现异常,5例T2WI及FLAIR图像上清晰显示病灶;1例合并出血性梗死者局部表现为高灌注(rCBF=1.32±0.15)。7例脑血管畸形中,3例病变区呈显著高灌注(rCBF=2.54±1.23);2例静脉畸形的ASL图像上脑血流灌注无明显异常;2例脑海绵状血管瘤中1例瘤体内呈低灌注(rCBF=0.80±0.05),1例无明显异常(rCBF=1.1±0.00);7例脑血管畸形病变区rCBF均值为1.58±1.06。Mann-Whitney U轶和检验结果显示两组中rCBF的差异有统计学意义(P<0.05)。结论:儿童脑血管畸形所累及区域的rCBF往往高于烟雾病,可能与儿童供血动脉或侧支循环代偿机制不同有关;3D-ASL脑灌注成像对儿童脑血管病变的诊断有重要价值。  相似文献   

9.
目的评估透视触发和并行采集技术用于高分辨率三维增强颈动脉磁共振血管成像术(3DCEMRA)的可行性。方法80个临床诊断或怀疑颈动脉狭窄的病人接受3DCEMRA检查。使用透视触发软件触发启动颈动脉3DCEMRA扫描,同时采用K空间椭圆形中心填充法和加速因子为2的并行采集技术。对显示的各段动脉和有无静脉早期显影做分析。动脉狭窄分成动脉管壁不规则、轻度狭窄、严重狭窄和闭塞。颈动脉3DCEMRA的显示结果与其他检查结果做了对照。结果所有病例均顺利触发和完成颈动脉3DCEMRA检查。3DCEMRA显示了80例病人总共800支动脉段(100%显示率),所有病例在动脉显示区域内静脉均未显影或显影很淡,对诊断不构成影响。结果显示有680段动脉正常、41段动脉管壁不规则、24段动脉轻度狭窄、51段严重狭窄和4段闭塞。另外10段颈动脉狭窄处溃疡形成,12例患者除见颈动脉狭窄以外,还发现合并椎动脉和/或锁骨下动脉狭窄。36例病例,与其他血管成像技术作了比较,3DCEMRA的检查结果与之完全符合,未出现高估或低估血管狭窄程度。结论透视触发并行采集高分辨率3DCEMRA简单可行,成像时间短,空间分辨率高,能清楚显示颈动脉,它将在颈动脉狭窄的诊断中起重要作用。  相似文献   

10.
随着磁共振血管成像(MRA)技术的发展,影像质量不断提高,应用范围不断扩大,在某些方面甚至比数字减影血管造影(DSA)更有优势.K-空间椭圆中心编码作为一种新的对比增强MRA技术,能够明显改善数据采集效率从而提高影像质量.综述三维椭圆中心采集对比增强MRA的技术特点、临床应用价值及方法.  相似文献   

11.
三维动态增强MR血管成像对门静脉高压症的评价   总被引:2,自引:0,他引:2  
目的通过规范扫描时相、增加三维采集厚度及采用减影后处理技术,评价三维动态增强MR血管成像(3D DCE MRA)对显示门静脉高压症患者侧支循环的作用。方法30例门静脉高压症患者进行3D DCE MRA,其中12例采用75~90 mm的三维采集厚度,扫描时相以呼吸次数粗略估计,采集3-5次,18例采用150~180 mm三维采集厚度,扫描时相以秒表计时确定,分别于0、20、40、60、90 s采集5次。比较减影前后的最大强度投影(MIP)重组图像对门静脉系统血管主干及侧支的显示能力(以4级法评价),并统计患者显示的所有侧支血管及其显示的最佳时间。结果减影技术会降低门静脉主干的显示效果[减影前(2.74±0.31)级,减影后(2.53±0.49)级],差异有统计学意义(t=2.65,P<0.05),而提高食管胃底曲张静脉的显示[减影前(1.63±0.50)级,减影后(2.58±0.30)级],差异有统计学意义(t=-12.56,P<0.01)。门静脉主干与多数侧支循环为20 s左右显示最佳,个别侧支血管显影延迟。结论采用减影后处理技术能提高对门静脉高压症患者侧支血管的显示,规范的扫描时相不会遗漏显影较晚的侧支循环,增大采集厚度能保证前后腹壁侧支循环的显示。  相似文献   

12.
腔静脉三维动态增强磁共振血管成像   总被引:7,自引:0,他引:7  
目的 评价三维动态增强磁共振血管成像(3D DCE MRA)用于诊断腔静脉病变的价值。方法 52例疑有腔静脉畸形、血栓形成、狭窄、闭塞或受压的患者接受了3D DCE MRA成像检查。分析3D DCE MRA的图像质量及其对各种腔静脉病变和侧支循环的显示情况,并把33例3D DCE MRA同常规腔静脉造影术(15例)和手术(18例)进行比较。结果 52例3D DCE MRA图像均无伪影,血管显示清楚  相似文献   

13.
SENSE技术在磁共振腹部动态增强血管成像中的应用   总被引:2,自引:0,他引:2       下载免费PDF全文
目的:探讨磁共振敏感编码技术在腹部动态增强血管成像(DcE—MRA)中的应用优势。方法:将疑有腹部血管疾病的40例患者分为二组,实验组20例使用SENSE技术扫描;另外20例为对照组,直接行DCE—MRA扫描。结果:对照组20例中,13例因患者呼吸配合好,图像清晰,其中5例显示了动、静脉不同时相,8例由于扫描时间长,得到动、静脉均显影的图像。其余7例因屏气配合不好,图像出现伪影,为诊断带来了困难。实验组20例患者由于扫描时间明显缩短,均获得了清晰且不同时相的图像。结论:sENsE技术的使用大大地缩短了扫描时间,使腹部DCE—MRA可不受呼吸影响,并能获得不同时相血管强化图像,明显改善了DcE—MRA影像的质量,提高了诊断准确性。  相似文献   

14.
目的:探讨Tim(total image matrix)技术行三维动态增强磁共振血管造影(3D DCE MRA)的临床应用价值。方法:采用Avanto 1.5T MR,Tim外周血管线圈,自动移床及无缝连接技术,行3D DCE-MRA检查(3D-FLASH自减影序列,TR 2~4ms,TE 1~2ms,层厚1.5~2.0mm);通过双筒高压注射器经肘正中静脉注射对比剂Gd-DTPA,浓度0.5mmol/ml,总量30ml,流量2.5ml/s;扫描延迟时间195例采用Test-bolus法,40例采用Care-bolus法;后处理对靶血管作最大信号强度投影(MIP)重建。共235例行3D DCE MRA,包括颈动脉63例,胸、腹主动脉34例,肺动脉21例,肾动脉25例,肝动脉24例,双下肢动脉56例,全身动脉12例。其中45例经数字减影动脉血管造影(IADSA)或(和)手术证实;图像质量采用优、良、差三级评价。结果:235例3D DCE MRA图像质量优良者225例,占95.4%。45例经手术I、ADSA证实的3D DCE MRA的敏感性、特异性和准确性分别为93.5%、78.6%和88.9%;假阳性3例,假阴性2例;病变程度低估、高估各1例。3D DCEMRA结果与IADSA或(和)手术符合率为88.9%,主动脉及其主要分支病变符合率为92.9%,较细分支病变符合率为87.1%。结论:Tim线圈、自动移床及无缝连接技术3D DCE MRA是一种全新、无创或微创性血管显像技术,正确掌握延迟时间是3D DCE MRA成功的关键,评价主动脉及其主要分支病变有较高的可靠性,但对动脉较细分支的分辨率尚有待于进一步提高。  相似文献   

15.
PURPOSE: To assess the usefulness of centrally fat-saturated three-dimensional magnetic resonance (MR) angiography of the abdomen using an elliptical centric view order and selective placement of fat-saturation pulses in the central 30% portion of the k-space in terms of fat signal reduction, image contrast of post-contrast images, and breath-holding time. METHODS: Fat signal in abdomen and breath-holding time were compared between centrally fat-saturated three-dimensional sequence and partially fat-saturated three-dimensional sequence or conventional fat-saturated three-dimensional sequence. Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography was obtained at arterial and equilibrium phases, and image quality was quantitatively and visually evaluated. RESULTS: Centrally fat-saturated three-dimensional sequence suppressed fat signal, as did the conventional fat-saturated three-dimensional sequence, and the breath-hold was prolonged only by 1.5 seconds compared to the partially fat-saturated three-dimensional sequence. Contrast-enhanced centrally fat-saturated three-dimensional MR angiography provided abdominal MR arteriography with large signal difference between vessels and fat, while venous signal was insufficient at equilibrium phase. CONCLUSION: Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography using an elliptical centric view order and selective central fat-saturation of k-space reduced fat signal comparable to conventional fat-saturated three-dimensional sequence, and provided contrast-enhanced MR arteriography with high vascular contrast and minimum prolongation of breath-hold.  相似文献   

16.
Purpose: To evaluate the diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the supra-aortic arteries using the CareBolus technique. Digital subtraction angiography was the standard of reference. Material and Methods: Fifty consecutive patients with suspected internal carotid artery stenosis underwent CE-MRA and digital subtraction angiography. CE-MRA was performed on a 1.5-T superconducting scanner with the CareBolus technique. CareBolus combines a nearly real-time 2D-FLASH (fast low angle shot) sequence for fluoroscopic triggering and a high-resolution 3D-FLASH with elliptical centric view order for the angiographic pulse sequence (6.0/2.16 ms [TR/TE], 30° flip angle, 30.98 s acquisition time, 0.88 mm effective (interpolated) partition thickness and a 160×512 matrix). Intra-arterial digital subtraction angiography and CE-MRA studies were evaluated independently by four blinded readers. Internal carotid artery stenoses were graded according to the NASCET criteria. Results: CE-MRA had an accuracy of 92.53%, a sensitivity of 95.64%, and a specificity of 90.39% for the identification of carotid artery stenoses ≥70% (grade 3). Image quality for suppression of stationary tissue and venous contrast was good, but was reduced in five cases due to patient motion. Conclusion: The CareBolus technique is a useful non-invasive method for high-resolution imaging of the supra-aortic vessels because of its easy application and high sensitivity and specificity. Limitations can occur in non-compliant patients due to motion artifacts during the measurement time.  相似文献   

17.
18.
三维动态增强磁共振血管成像在肝移植术前的应用   总被引:1,自引:1,他引:0  
王宏  钟心  董玉茹  董悦 《武警医学》2005,16(10):748-751
 目的探讨三维动态增强磁共振血管成像(3D DCE MRA)三期扫描技术,评价其在肝移植术前的诊断价值.方法对拟进行肝移植的183例患者进行术前3D DCE MRA成像扫描,采用Siemens Symphony 1.5T超导MRI扫描机,圆形极化相控阵体线圈,3D DCE MRA三期(动脉期、门脉期和静脉期)扫描技术,即对所得图像进行综合评价.结果全部病例均获得了满意的血管成像图像,肝动脉可显示2~3级分支,门静脉可显示2~5级分支,肝静脉可显示1~2级分支.183例肝移植患者,5例显示肝动脉变异,其中2例起自肠系膜上动脉,2例直接起自腹腔干,1例起自胃左动脉.单纯肝硬化门脉高压103例,其中,冠状静脉和食道胃底静脉曲张23例、脐周静脉曲张5例、肠系膜静脉曲张2例、脾门周围静脉曲张30例,门静脉玻璃样变性1例;原发性肝癌79例,5例肝动脉包埋、僵直、推移,2例肝内动-静脉瘘,门静脉右支癌栓23例,门静脉左支癌栓7例,门静脉主干癌栓3例,同时发生门静脉左右支癌栓的2例,MRA表现为门静脉呈半月形或杯口形缺损或不显影.7例肝静脉出现栓塞,5例下腔静脉受压推移,1例下腔静脉瘤栓.结论 3D DCE MRA三期扫描能很好的显示肝动脉、门静脉、肝静脉及下腔静脉系统病变,肝移植术前应用3D DCE MRA,基本达到临床要求,是术前血管评估的有效方法.  相似文献   

19.
The purpose of this study was to compare the image quality of the intravascular contrast agent gadofosveset with the extracellular contrast agent gadoterate meglumine in time-resolved three-dimensional magnetic resonance (MR) angiography of the human arteries of the hand. The value of cuff compression technique for suppression of venous enhancement for both contrast agents was also investigated. Three-dimensional MR angiograms of both hands of 11 healthy volunteers were acquired for each contrast agent at 1.5-T, while subsystolic cuff compression was applied at one side. Quantitative and qualitative evaluation were performed and analyzed with Student’s t-test. Visualization of vessels was superior in the images acquired with gadofosveset, especially in the late phases. Quantitative and qualitative evaluation showed significantly higher values for gadofosveset. The cuff compression at the lower arm proved to be an effective method to enhance arterial vessels. In conclusion the blood pool agent gadofosveset is superior for the dynamic imaging of the vessels of the hand when compared with the extracellular contrast agent gadoterate meglumine. To fully utilize the advantages of intravascular contrast agents, venous overlay has to be delayed or reduced, which can be achieved effectively by subsystolic lower arm cuff compression.  相似文献   

20.
目的评价导航技术三维对比剂增强磁共振冠状动脉成像的应用价值。方法应用导航技术三维对比剂增强磁共振血管成像方法,对20例受检者分别进行左、右冠状动脉成像,经后处理获得左、右冠状动脉血管图像。应用信噪比和对比噪声比评价增强前后的冠状动脉图像,并对冠状动脉主干及其主要分支的显示情况进行评价。结果(1)对获得成功的18例冠状动脉图像进行评价,增强前冠状动脉图像的信噪比为26.37±7.02,对比噪声比为14.76±6.97;增强后冠状动脉图像的信噪比为38.87±11.62,对比噪声比为33.72±10.80,经统计学比较,信噪比和对比噪声比增强前后的差异有统计学意义(t=2.91,4.62;P<0.05)。(2)对比剂增强后左、右及左回旋支冠状动脉近中段的显示率为100%,远侧段的显示率分别为94.4%、88.8%、77.8%。结论导航技术三维对比剂增强磁共振冠状动脉成像有较高的信噪比和对比噪声比,应用于临床尚需进一步的对照研究。  相似文献   