首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的:分析老年人收缩压变异性(BPV)与肾小球滤过率之间的关系。方法:在参加开滦研究队列第三次健康体检的人群中,采取整群抽样的方法随机抽取年龄≥60岁的开滦集团离退休员工进行24 h动态血压监测等检查。在随机抽取的3 064例受试者中,2 464例符合入选标准并接受肾功能测定,以估算肾小球滤过率(e GFR)作为肾功能评定指标,资料完整并符合入选标准者共1 382例。以短时收缩压极差(MMD)作为收缩压变异性指标,采用逐步线性回归方法,分析收缩压MMD与e GFR的相关性。结果:1 382例受试者的平均年龄为(67.16±5.86)岁,其中男性905例(65.5%);e GFR水平随着收缩压MMD的增加而降低(P0.05);Pearson相关分析结果显示,e GFR与24 h、日间、夜间收缩压MMD均呈负相关(P0.05)。多因素逐步线性回归分析结果显示,24 h、日间收缩压MMD与e GFR呈负线性相关。结论:24 h和日间收缩压MMD与e GFR呈负线性相关。  相似文献   

2.
目的探讨老年高血压患者通过抗高血压治疗,其血压控制在正常范围后收缩压变化与肾功能的关系。方法选择老年男性原发性高血压患者436例,根据年龄分为老年组194例(65~80岁),高龄组242例(81~101岁)。又根据估算的肾小球滤过率(e GFR)分为e GFR 1组203例[e GFR 89 ml/(min·1. 73 m2)],e GFR 2组129例[60~89 ml/(min·1. 73 m2)],e GFR 3组104例[60 ml/(min·1. 73 m2)]。采用多元线性回归分析e GFR与血压控制不良的关系。结果老年组TC、LDL-C、e GFR、24 h舒张压、24 h舒张压负荷、夜间收缩压减少和夜间舒张压减少明显高于高龄组,年龄、糖尿病、冠心病、尿酸、夜间收缩压、24 h收缩压负荷明显低于高龄组(P 0. 05,P 0. 01)。与e GFR 1组比较,e GFR 2组和e GFR 3组昼间收缩压、夜间收缩压、24 h收缩压变异性明显增加,夜间收缩压减少和夜间舒张压减少明显降低(P 0. 05);与e GFR 1组比较,e GFR 3组24 h收缩压负荷明显增加[(39. 66±25. 79) mm Hg vs (34. 79±26. 18) mm Hg,1 mm Hg=0. 133 k Pa,P 0. 01]。多元线性回归分析显示,调整潜在的混杂因素后,24 h收缩压变异性和尿酸与e GFR相关(P 0. 01)。结论在24 h动态血压监测的参数中,24 h收缩压变异性是老年高血压患者肾功能下降的惟一独立危险因素。  相似文献   

3.
目的探讨长时(年度间)和短时(24h)收缩压变异性(SBPV)指标与老年人群大血管功能及结构的相关性。方法在参加开滦研究队列2010-2011年第3次健康体检的人群中,采取整群抽样的方法随机抽取年龄≥60岁的开滦集团离退休员工进行24h动态血压监测等检查。在随机抽取的3064名观察对象中,符合入选标准者2464名。SBPV采用收缩压标准差(SSD)、独立变异性(VIM)、收缩压极差(MMD)和平均真实变异性(ARV)4种指标;大血管功能及结构采用臂踝动脉脉搏波传导速度(baPWV)和颈动脉内膜中层厚度(CIMT)两种指标。采用多元逐步线性回归方法,分析不同年度间和24hSBPV指标与baPWV、CIMT的相关性。结果2464名观察对象年龄(67.4±6.1)岁,男性1667名(67.7%)。按各SBPV中位数分组,年度间、24h、日间SSD、MMD和ARV分组中,高水平SBPV组的baPWV、CIMT均高于低水平SBPV组。多元逐步线性回归分析显示,年度间SSD、VIM、MMD与baPWV呈正相关(B=55.50、57.35、24.34,均P0.01),年度间VIM与CIMT呈正相关(B=0.02,P0.05);短时(24h、日间、夜间)SBPV指标与baPWV无线性相关(均P0.05),24h、日间SBPV与CIMT呈正相关(均P0.05);24h、日间、夜间和年度间平均收缩压与baPWV、CIMT呈正相关(均P0.05)。结论长时SBPV与baPWV呈正相关,而短时SBPV与baPWV无相关;年度间VIM及24h、日间SBPV与CIMT呈正相关。  相似文献   

4.
目的探讨诊室、随诊间、24h收缩压与老年人颈动脉内膜中层厚度(CIMT)的相关性。方法 2006-2007年第1次对开滦集团公司在职及离退休职工进行健康体检,此后分别于2008-2009、2010-2011年进行第2、3次健康体检,并于第3次体检时整群随机抽取年龄≥60岁的开滦集团离退休员工2814例进行动态血压监测、颈部血管彩色多普勒超声心动图等检查。最终符合入选标准2464人。采用多元逐步线性回归分别分析诊室、随诊间、24h、日间、夜间收缩压与CIMT的关系。结果研究对象2464人,男性1667人,女性797人,平均年龄67.4岁。按照不同收缩压三分位分别将研究对象分为3组,随着不同收缩压水平增加,CIMT显著增厚(均P0.01)。多元逐步线性回归分析显示:校正混杂因素后,诊室、随诊间、24h、日间、夜间收缩压均与CIMT呈线性正相关,收缩压每增加1mm Hg,CIMT分别增加0.001、0.002、0.002、0.002、0.002mm(均P0.01)。去除24h收缩压后(存在多重共线性),比较诊室、随诊间、日间、夜间收缩压与CIMT的关联大小的回归结果显示,随诊间、日间收缩压与CIMT呈线性相关,且随诊间收缩压与CIMT的关联大于日间收缩压(β值分别为0.154、0.098)。结论诊室、随诊间、24h、日间、夜间收缩压均与CIMT相关,其中随诊间收缩压与CIMT相关性最大。  相似文献   

5.
目的探讨不同短时收缩压(SBP)变异性(SBPV)指标与老年人群臂踝脉搏波传导速度(baPWV)的相关性。方法在参加开滦研究队列第三次健康体检的人群中,采取整群抽样的方法随机抽取年龄≥60岁的开滦集团离退休员工进行24 h动态血压监测等检查。在随机抽取的3 064例观察对象中,符合入选标准者2 464例,最终纳入统计分析者1 004例。SBPV采用标准差(SSD)、独立变异性(VIM)、极差(MMD)和平均真实变异性(ARV)为观察指标。采用逐步线性回归方法,分析不同短时SBPV指标与baPWV的相关性。结果 (1)除VIM外,随着平均SBP的增加,短时SBPV指标SSD、MMD、ARV均呈上升趋势(P0.05)。(2)在逐步线性回归分析中,校正其他混杂因素后,不同短时SBPV指标均与baPWV无线性相关(P0.05),短时平均SBP均与baPWV呈正相关(P0.05)。结论不同短时SBPV指标与baPWV均无线性相关。  相似文献   

6.
目的 探讨隐蔽性未控制高血压(MUCH)患者交感神经活性、靶器官受损(TOD)的变化。方法 共纳入接受高血压治疗且诊室血压达标<140/90 mmHg患者350例作为研究对象,同步检测24 h动态血压和动态心电图,计算血压变异性(BPV)和心率变异性(HRV)。根据24 h动态血压是否达标分为:已控制高血压组(CH组)109例和MUCH组241例。检测并计算尿白蛋白/肌酐比值(ACR)、肾小球滤过率(eGFR)、颈动脉内中膜厚度(IMT)、左心室质量指数(LVMI)。分析比较两组HRV、BPV及尿ACR、eGFR、IMT、LVMI的变化;进行Pearson线性相关分析;并采用多元线性回归分析MUCH患者TOD的危险因素。结果 MUCH发生率为68.86%。与CH组比较,MUCH组总体标准差(SDNN)、差值均方根(rMSSD)和大于50 ms百分比(pNN50)显著降低(P>0.05);日间、夜间及24 h收缩压变异系数(CV)和舒张压CV显著升高(P>0.05);eGFR显著降低;尿ACR、IMT、LVMI显著增加(均P>0.05)。相关及回归分析显示SDNN...  相似文献   

7.
目的探讨24 h动态收缩压(SBP)与老年人群臂踝脉搏波传导速度(ba PWV)的关联性。方法 2006~2007年第1次对开滦集团公司在职及离退休职工进行健康体检,此后分别于2008~2009、2010~2011年进行第2、3次健康体检,并于第3次体检时整群随机抽取年龄≥60岁的开滦集团离退休员工2814例进行动态血压监测、ba PWV测定等检查。符合入选标准的为2464例,资料完整者1004例。采用多因素线性回归分别分析24h SBP、日间SBP、夜间SBP与ba PWV的关联性。结果 (1)按照24h SBP、日间SBP、夜间SBP三分位数分别将研究对象分为3组,随着24h SBP、日间SBP、夜间SBP升高,ba PWV均增加(均P0.001)。(2)多因素线性回归分析显示:校正混杂因素后,24h SBP、日间SBP、夜间SBP每增加1个标准差,ba PWV分别增加81.15、73.18、81.30 cm/s;此外,诊室SBP也与ba PWV呈线性正相关,且回归系数大于动态SBP。结论 24h SBP、日间SBP、夜间SBP与ba PWV呈正相关,但关联性弱于诊室SBP。  相似文献   

8.
目的探讨原发性高血压(EH)患者24h动态血压变异性(BPV)与血浆同型半胱氨酸(HCY)水平的相关性。方法将148例高血压病患者和40名健康对照人群行24h动态血压监测及血浆HCY、血糖、血脂检测,测定24h平均收缩压(SBP)、平均舒张压(DBP)、收缩压标准差(SSD)、舒张压标准差(DSD)及HCY、血糖、血脂水平。并根据HCY水平将高血压组患者分为伴HCY升高的高血压(H型高血压)组和不伴HCY升高的高血压(非H型高血压)组。比较3组人群动态血压与HCY水平,并分析其相关性。结果与对照组比较,H型高血压组及非H型高血压组总胆固醇、低密度脂蛋白胆固醇、血浆HCY水平、24hSBP、24h DBP、24hSSD以及24hDSD显著升高,差异有统计学意义(P0.01);与非H型高血压组比较,H型高血压组血浆HCY水平、24h SSD以及24hDSD显著升高,差异有统计学意义(P0.01)。多重线性回归分析显示,高血压病组(包括H型高血压和非H型高血压)SSD与HCY(P=0.000)、LDL-C(P=0.038)呈显著正相关;DSD与HCY(P=0.024)、LDL-C(P=0.042)呈显著正相关。结论高血压病患者24h动态血压变异性指标SSD、DSD与血浆HCY水平显著正相关。血浆HCY升高可能是BPV升高的危险因素之一。  相似文献   

9.
目的探讨诊室、随诊间、24h动态收缩压与老年人群肾脏损害的关系。方法 2006-2007年第1次对开滦集团公司在职及离退休职工进行健康体检,此后分别于2008-2009、2010-2011年进行第2、3次健康体检,并于第3次体检时整群随机抽取年龄≥60岁的开滦集团离退休员工2814人进行动态血压监测、尿微量白蛋白(MAU)测定等检查。符合入选标准共2464人。采用多因素线性回归分别分析诊室、随诊间、24h、白天、夜间收缩压与估算的肾小球滤过率(eGFR)、MAU的相关性。结果 2464名研究对象,男性1667人,女性797人,平均年龄67.4岁。按照不同收缩压三分位数分为3组,lgMAU随不同收缩压升高而增加,而eGFR随诊室、随诊间收缩压升高而降低。校正混杂因素后,多因素线性回归分析显示:诊室、随诊间、24h、白天、夜间收缩压均与MAU呈正相关,而只有随诊间收缩压与eGFR呈线性负相关。去除24h收缩压(存在多重共线性问题)后,比较诊室、随诊间、白天、夜间收缩压与eGFR、MAU相关性的回归结果显示,随诊间收缩压与eGFR呈负相关(B=-0.72,P=0.001),白天收缩压与MAU呈正相关(B=2.84,P=0.011)。结论诊室、随诊间、24h、白天、夜间收缩压与肾脏损害相关。  相似文献   

10.
【摘要】 目的 研究非透析慢性肾脏病(CKD)患者动态血压特征,探讨血压昼夜节律及血压变异性与左室肥厚的关系。方法 收集118 例CKD非透析患者,测量肾功能、血脂等生化指标,按其eGFR水平分为CKD1~2期组(n=22例),CKD3期组(n=47例),CKD4~5期组(n=49例)。另收集同期健康体检者30 例作为对照组。采用动态血压监测仪监测24h动态血压,超声心动图检测LVH 有关指标。分析CKD患者动态血压特征,探讨血压昼夜节律及血压变异性与左室肥厚的关系。结果 ①CKD各组的24 h、日间、夜间的SBP和DBP的平均值都高于对照组,差异有统计学意义(P<0.05) 。随着肾功能的下降,24h、日间和夜间SBP和夜间DBP的平均值越来越高。②与对照组相比,CKD各组24h平均收缩压标准差(24 h SSD)、白昼收缩压标准差(d SSD)、夜间收缩压标准差(n SSD) 与夜间舒张压标准差(n DSD)均明显升高,差异有统计学意义(P<0.05);随着肾功能的下降,24 h SSD、d SSD、n SSD与n DSD均明显升高,组间比较差异有统计学意义[(11.93±3.8)vs(13.98±2.9),(14.37±3.7);(12.7±4.3) vs(14.9±4.1),(15.2±4.6);(10.9±3.7)vs(11.89±4.2),(12.11±4.7);(8.9±4.1) vs (10.44±2.9),(10.76±3.16);P<0.05 ]。各组24h平均舒张压标准差(24 h DSD)、白昼舒张压标准差(d DSD)比较差异无统计学意义。③CKD患者总体非杓型血压比例为80.5%, CKD各期非杓型血压比例分别为CKD1~2期68.2%,CKD3期78.7%,CKD4~5期87.8%,均显著高于对照组20%。④与非左心室肥厚组(non-LVH 组)相比:左心室肥厚组( LVH 组)24 h、白昼、夜间SBP 与DBP 平均值升高,差异有统计学意义(P<0.01);非杓型血压发生率升高(65.4% vs 83.5%),两者比较差异有统计学意义(P<0.05);LVH 组24 h SSD、d SSD与n SSD明显高于无LVH 组,差异有统计学意义(P<0.05)。结论 随着肾功能减退,CKD 患者血压均值升高;昼夜节律改变,以非杓型血压为主;血压变异性增大。CKD患者LVH 的发生与血压升高、血压昼夜节律异常及血压变异性尤其收缩压变异性增大与密切相关。  相似文献   

11.
Although automated monitors for blood pressure (BP) measurement are used increasingly worldwide, understanding of how such devices are used in Brazil is low. This study analyzed the status of BP measurement by Brazilian health professionals. A questionnaire regarding experience with BP measurement was sent electronically to Brazilian nurses, nursing assistants, and doctors. It had 2004 responses. Previous experience with use of automated monitors was most frequent in men (71.2%), nursing technicians (65.5%), specialists (61.1%), secondary care (71.9%), emergency care (70.6%), or the private sector (66.3%). The least complied aspects of the standardized measurement protocol were availability of various cuff sizes (53.9% and 72.9% for auscultatory and oscillometric methods, respectively) and proper calibration checks (21.5% and 46.8% for auscultatory and oscillometric methods, respectively). Brazilian health professionals report not adequately performing all the necessary aspects to measure BP in accordance with the standardized protocol in both methods, but mainly regarding the oscillometric.  相似文献   

12.
Summary Mean arterial pressure (MAP) is the area under the pressure wave form averaged over the cardiac cycle. A widely used rule of thumb to estimate MAP of peripheral arterial pressure waves in adults is adding one-third of the pulse pressure (PP) to diastolic arterial pressure (DAP). However, radial artery pressure waves in newborns differ from those in adults and resemble proximal aortic pressure waves, so that the above-mentioned calculation of MAP may not be correct. The present study was set up to obtain an arithmetical approximation to derive MAP from blood pressure waves measured in the radial artery of the neonate. We accurately recorded about 300 invasively obtained blood pressure curves in the radial artery of 10 neonates admitted for intensive care. We found that MAP in the radial artery in these neonates can be well approximated by adding 46.6% PP to DAP (range 43.0–50.1%). We suggest that the rule of thumb to derive MAP from radial artery waves in the neonate to be approximately the average of systolic and diastolic pressure, as opposed to adding one-third of the pulse pressure to the diastolic value in the adult.Abbreviations ABP Arterial blood pressure - SAP Systolic arterial pressure - DAP Diastolic arterial pressure - MAP Mean arterial pressure - PP Pulse pressure - MAP% (MAP-DAP)/(SAP-DAP)×100% (i.e., level of the MAP in the wave, expressed in % PP) - PDA Patent ductus arteriosus - IRDS Idiopathic respiratory distress syndrome  相似文献   

13.
To simplify the estimation of end-systolic aortic pressure ( P es) noninvasively, a regression equation was derived from intra-arterial measurements. Peak-systolic ( P ps), P es, and diastolic aortic pressure ( P d), pulse pressure ( P p), heart rate, hemoglobin, body weight, and height were measured. Cardiac index and body surface area were calculated in 66 patients (17 with aortic runoff lesions, group I; 49 without lesions, group II) with various heart diseases without aortic stenosis (35 males, 31 females, mean age 4.6 years) during the course of diagnostic catheterization. Using a stepwise regression analysis, the following relationship was determined from the combined groups: P es= 0.422* P ps+ 0.617* P d+ 1.377. The correlation between P es measured directly and P es calculated from our formula was quite strong( r = 0.957, P = 0.0001), as was the correlations between each subgroup ( r = 0.948, group I; r = 0.959, group II). The correlation between P es calculated and that estimated using an indirect carotid pulse tracing method was also strong ( r = 0.912, P = 0.0001, n = 31). This regression equation appears applicable to infants or children with aortic runoff lesions in whom it is difficult to measure P es by noninvasive methods using the carotid pulse. (ECHOCARDIOGRAPHY, Volume 8, September 1991)  相似文献   

14.
Method for noninvasive measurement of central aortic systolic pressure   总被引:1,自引:0,他引:1  
A method for noninvasive generation of central aortic systolic pressure curves is presented. The method is based on plotting the occlusive pressure values applied at the brachial artery level against the time intervals needed for the aortic pressure wave to equalize and break through the occlusive pressure at the brachial artery level. These time intervals were obtained by measuring the time from the beginning of depolarization (the QRS complex) to the detection of the pressure wave at the temporarily occluded brachial artery. The validity of the method was documented by 3 different approaches. The pressure values measured by a device developed by us were superimposed on the simultaneously measured central intra-aortic pressure waves and all values were within one standard deviation from the central aortic recordings in 8 of the 10 patients studied. At the same time, the noninvasively recorded pressure waves were completely different from the peripheral artery pressure recorded simultaneously at the femoral artery site. The DP/DT values derived from the central aortic recordings and the noninvasive device correlated (r = 0.83). These results indicate that the noninvasive device measures the central aortic pressure or a close approximation of it. By combining noninvasive pressure measurements with volume measurements obtained by radionuclide angiography, noninvasive pressure-volume curves were generated in 10 subjects. Possible clinical application of the systolic noninvasive pressure-volume curves is suggested.  相似文献   

15.
血脂康在老年高血压患者降压治疗中对血压和脉压的影响   总被引:1,自引:0,他引:1  
目的 观察血脂康在老年高血压患者降压治疗中对血压和脉压的影响.方法 将经氨氯地平(5 mg,1次/d)降血压治疗后达到轻度高血压标准的老年高血压患者58例随机分为两组,血脂康组30例和对照组28例.对照组采用低脂、低盐饮食及按原剂量服用氨氯地平;血脂康组在此基础上加用血脂康600 mg,2次/d,连续服用12周,比较两组治疗前与治疗12周时血压和脉压的变化.结果 与治疗前比较,血脂康组治疗12周收缩压降低,分别为(149±9)mm Hg与(130±8)mm Hg;脉压缩小,分别为(64±11)mm Hg与(48±7)mm Hg(均为P<0.05);12周时组间比较,血脂康组优于对照组,收缩压分别为(130±8)mm Hg与(144±9)mm Hg,脉压为(48±7)mm Hg与(60±10)mm Hg(均为P<0.05).结论 老年高血压患者降压治疗中,应用常规剂量血脂康治疗可以起到降低血压的作用效应.  相似文献   

16.
目的:了解血压控制不达标高血压患者收缩压、舒张压、脉压、平均动脉压、血压控制不达标类型以及血压分级等血压特点及其与脑卒中患病情况的关系。方法:2012年3月至12月在北京安贞医院门诊及所属社区卫生服务中心门诊筛查血压控制不达标的高血压患者,共收集血压控制不达标高血压患者3909人。结果:研究对象男性占49.4%,女性占50.6%。62.2%患者服用一种降压药,37.8%联合用药。144例患缺血性脑卒中,患病率为3.68%。多因素回归分析发现,和收缩压及舒张压均未控制的患者相比,单纯舒张压控制不达标者脑卒中的患病危险低,OR=0.339(95%CI:0.124-0.923)。和收缩压<140 mmHg者相比,收缩压高于150mmHg者缺血性脑卒中的患病危险增加,收缩压150~159mmHg以及≥160mmHg者相对危险度分别为2.532 (95%CI:1.266-5.067),和2.004(95%CI:1.010-3.979)。而脉压差、平均动脉压、舒张压以及血压分级在多因素分析中均为显示与缺血性脑卒中的相关关系。结论:单纯舒张压控制不达标类型以及收缩压水平与缺血性脑卒中的患病危险相关。单纯舒张压控制不达标的患者以及收缩压高于150 mmHg者缺血性脑卒中的患病危险增加。  相似文献   

17.
目的 :动态血压测定值常因地区、种族、时节不同而异。方法 :我们于 1996年~ 1998年对成都地区 2 0 0例中老年人进行了 2 4小时动态血压监测。结果 :平均年龄 5 8.15± 8.19岁 ,昼夜均值 93~ 146 / 5 2~ 93mm Hg,日间均值10 0~ 135 / 5 9~ 92 m m Hg,夜间均值 10 0~ 132 / 5 5~ 83mm Hg,昼夜平均压均值 93± 10 .19mm Hg,血压负荷值 12~ 30 /10~ 15 %。结论 :本组结果可作为成都地区动态血压的参考正常值  相似文献   

18.
目的采用美国医疗器械检测协会(AAMI)标准,对HEM-6000手腕式血压计的血压测量精确度进行临床验证研究。方法入选对象为18岁以上成年人,共91人。腕部测压结果与听诊法比较。每位受试者用2种方法同时各进行3次坐位血压测量,对91人的273对血压测量值用以下2种方法进行统计分析:(1)先计算出2种测压方法得到的血压测量值误差,再求得误差的平均值和标准偏差。(2)先计算出每位受试者用2种测压方法得到的血压平均值的差值,再求得该差值的平均值和标准偏差。结果根据方法1得到的收缩压(SBP)和舒张压(DBP)的测量误差分别为(0.5±7.1)mm Hg和(-1.6±6.1)mm Hg;根据方法2得到的结果分别(0.5±6.1)mm Hg和(-1.6±5.3)mm Hg。血压值的水平及手腕周长对测量误差无影响。结论HEM-6000手腕式血压计通过AAMI检验标准,可推荐患者用于家庭自我测压。  相似文献   

19.
目的 采用美国医疗器械检测协会(AAMI)标准,对HEM-6000手腕式血压计的血压测量精确度进行临床验证研究.方法 入选对象为18岁以上成年人,共91人.腕部测压结果与听诊法比较.每位受试者用2种方法同时各进行3次坐位血压测量,对91人的273对血压测量值用以下2种方法进行统计分析:(1)先计算出2种测压方法得到的血压测量值误差,再求得误差的平均值和标准偏差.(2)先计算出每位受试者用2种测压方法得到的血压平均值的差值,再求得该差值的平均值和标准偏差.结果 根据方法1得到的收缩压(SBP)和舒张压(DBP)的测量误差分别为(0.5±7.1)mm Hg和(-1.6±6.1)mm Hg;根据方法2得到的结果分别(0.5±6.1)mm Hg和(-1.6±5.3)mm Hg.血压值的水平及手腕周长对测量误差无影响.结论 HEM-6000手腕式血压计通过AAMI检验标准,可推荐患者用于家庭自我测压.  相似文献   

20.
Because pulmonary venous pressure has never been measured, it is unclear whether pulmonary wedge pressure measures left atrial pressure, as commonly assumed, or pressure more upstream in the pulmonary venous or capillary beds. Fluid-filled mean pulmonary artery and pulmonary wedge pressure were compared with pulmonary venous and left atrial pressure obtained with high-fidelity micromanometer catheters in eight lightly sedated dogs over a physiologic range of filling pressures. In all conditions, mean pulmonary wedge pressure was virtually identical (r = 0.99) to mean left atrial pressure (slope = 0.99; intercept = -0.46 mm Hg). At the same time, mean pulmonary venous pressure (17.1 +/- 6.5 mm Hg) was intermediate between mean pulmonary artery pressure (20.2 +/- 6.2 mm Hg) and mean pulmonary wedge pressure (13.3 +/- 6.2 mm Hg; P < 0.0001) or mean left atrial pressure (13.4 +/- 6.3 mm Hg; P < 0.0001). These relationships were maintained over normal and increased pressure ranges. As measured by conventional flow-directed pulmonary catheters, mean pulmonary wedge pressure accurately reflects left atrial pressure in lightly sedated, spontaneously breathing normal dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号