首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND AND OBJECTIVES: Capillary samples can provide blood for cell counts in haematologic patients and blood donors. However, some accept only values from venous blood. This study compares capillary and venous blood counts to verify the hypothesis that they are equivalent. MATERIALS AND METHODS: We analysed 463 capillary (fingerstick) and venous blood samples from 428 adults of both sexes (71% haematologic patients, 29% potential blood and apheresis donors). Both samples were taken at the same time from each subject. Haemoglobin (Hb), haematocrit (Hct), white blood cells (WBC), platelets, red blood cells (RBC), mean corpuscular volume (MCV), mean corpuscular Hb (MCH) and mean corpuscular Hb concentration (MCHC) were measured using a haematology analyser (Advia 120, Bayer). RESULTS: Capillary Hb, Hct, WBC, RBC, MCV and MCH were all significantly higher than the venous values [+0.2 mmol/l (+0.3 g/dl), +0.02 l/l (+2%), +0.2 x 10(9)/l, +0.1 x 10(12)/l, +3.1 fl and +0.01 fmol, respectively], whereas the capillary MCHC was lower (-0.6 mmol/l). There was no difference in platelets (-1 x 10(9)/l). Capillary Hb and Hct values were higher in patients with anaemia and polycythaemia, respectively. However, no significant differences occurred in severe thrombocytopenia. CONCLUSION: In adult haematologic patients, however, only the differences in Hb and Hct values may be of clinical relevance. For potential blood and apheresis donors, Hb and platelet screening are equivalent with either capillary and venous blood using a haematology analyser.  相似文献   

2.
Objectives: To provide reference values for haematological indices in Spanish adolescents according to age and gender. Methods: A cross sectional study conducted in five Spanish cities was performed. Blood was drawn from a representative sample of 581 adolescents with age ranging from 13 to 17–18.5 yr. Age‐ and gender‐specific means, standard deviations and percentiles were determined for the following parameters: total red blood cell counts (RBC), haemoglobin concentration (Hb), haematocrit percentage (Hct), mean corpuscular volume (MCV), mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, red cell distribution width and total white blood cell (WBC) counts as well as counts and percentage of neutrophils, lymphocytes, monocytes, eosinophils and basophils; platelet count (PLT), mean platelet volume and plateletcrit percentage. Results: Younger male subjects presented lower RBC, Hb, Hct and MCV means that their older counterpart. By contrast these differences were not observed in female subjects. As expected, RBC, Hb and Hct mean values in males were found significantly higher than in girls for all studied age groups. No significant differences were observed in WBC by age and gender. PLT values gradually decreased with age, except for females aged 17–18.5 yr. Conclusion: The present study provides reference data on the distribution of haematological indices of Spanish adolescents. These data can be useful biomarkers of the nutritional status in adolescents.  相似文献   

3.
The BC-3200 automated hematology analyzer was evaluated and compared with the Beckman-Coulter AcT (Ac.T diff 2) 3-part differential hematology analyzer. The BC-3200 was evaluated according to guidelines published by the International Committee for Standardization in Hematology (ICSH), Clinical and Laboratory Standards Institute (CLSI), and Department of Food and Drug Administration (FDA). The results demonstrated no background, minimal carryover (<0.5%), and excellent linearity for hemoglobin (Hb) level, white blood cell (WBC), red blood cell (RBC), and platelet (PLT) counts (>0.998). Precision was generally acceptable for all complete blood count (CBC) parameters; coefficients of variation (CVs) were within the manufacturer's claims and CVs of CBC parameters, including WBC, RBC and PLT counts, Hb and mean corpuscular volume, were <6%. Correlation between the BC-3200 and Ac.T diff 2 was excellent (r > 0.98) for all major CBC parameters (WBC, RBC, and PLT counts and Hb). We conclude that the overall performance of the BC-3200 is excellent and compares well with that of the Coulter Ac.T diff 2.  相似文献   

4.
No previous study has investigated the full range of complete blood count (CBC) parameters in small-for-gestational-age (SGA) newborns. The main aim of this study was to compare CBC and peripheral smear parameters in term, healthy SGA neonates and appropriate-for-gestational-age (AGA) neonates, and to establish CBC reference values for full-term SGA newborns. One hundred thirty-two healthy, term newborns (73 SGA and 59 AGA) were included. On day 1, we obtained 109 samples and on day 7 we obtained 77 samples. A CBC and peripheral smear were analyzed for each sample collected and group data were compared. We observed higher mean values for normoblast count, hemoglobin, hematocrit, and red blood cell (RBC) count in the SGA babies than in the AGA babies on day 1. The mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration values for the SGA babies were decreased because of the relatively high RBC count and relatively high mean corpuscular volume we observed in this group. Of the SGA newborns, 21.9% had neutropenia and 4.7% had absolute neutrophil counts lower than 1500/microl on day 1. On both day 1 and day 7, the SGA newborns had higher mean absolute metamyelocyte counts and higher mean I : T (immature : total neutrophil ratio) values than the AGA group. The SGA babies had a lower mean absolute lymphocyte count on day 7 than the AGA group. We detected thrombocytopenia in almost one-third of the 64 SGA newborns tested on day 1. In summary, our study clearly demonstrates that CBC parameters for healthy, full-term, SGA newborns are different from those of healthy, term AGA newborns. This is the first study that has documented different mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, metamyelocyte counts, lymphocyte counts, and I : T in SGA babies compared with AGA babies.  相似文献   

5.
No previous study has investigated the full range of complete blood count (CBC) parameters in small‐for‐gestational‐age (SGA) newborns. The main aim of this study was to compare CBC and peripheral smear parameters in term, healthy SGA neonates and appropriate‐for‐gestational‐age (AGA) neonates, and to establish CBC reference values for full‐term SGA newborns. One hundred thirty‐two healthy, term newborns (73 SGA and 59 AGA) were included. On day 1, we obtained 109 samples and on day 7 we obtained 77 samples. A CBC and peripheral smear were analyzed for each sample collected and group data were compared. We observed higher mean values for normoblast count, hemoglobin, hematocrit, and red blood cell (RBC) count in the SGA babies than in the AGA babies on day 1. The mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration values for the SGA babies were decreased because of the relatively high RBC count and relatively high mean corpuscular volume we observed in this group. Of the SGA newborns, 21.9% had neutropenia and 4.7% had absolute neutrophil counts lower than 1500/μl on day 1. On both day 1 and day 7, the SGA newborns had higher mean absolute metamyelocyte counts and higher mean I : T (immature : total neutrophil ratio) values than the AGA group. The SGA babies had a lower mean absolute lymphocyte count on day 7 than the AGA group. We detected thrombocytopenia in almost one‐third of the 64 SGA newborns tested on day 1. In summary, our study clearly demonstrates that CBC parameters for healthy, full‐term, SGA newborns are different from those of healthy, term AGA newborns. This is the first study that has documented different mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, metamyelocyte counts, lymphocyte counts, and I : T in SGA babies compared with AGA babies.  相似文献   

6.

Background

Although automated cell separators have undergone a lot of technical refinements, attention has been focused more on the quality of platelet concentrates than on donor safety. We planned this prospective study to observe the effects of automated plateletpheresis on normal haematological values of healthy donors and to determine whether the haematological alterations had any clinical consequences.

Study design and methods

The study was conducted on 457 healthy, first-time plateletpheresis donors over a period of 26 months. The plateletpheresis procedures were performed using five different cell separators and various pre- and post-donation haematological values such as haemoglobin concentration (Hb), haematocrit (Hct), platelet and white blood cell (WBC) counts, mean platelet volume and platelet distribution width were measured in all donors.

Results

We observed that the Hb, Hct, platelet and WBC counts decreased significantly in the donors (p<0.01) after each procedure, without there being significant changes in mean platelet volume or platelet distribution width. The decreases in Hb and Hct were significantly greater with the CS 3000 and Amicus machines, while the decreases in platelet and WBC counts were significantly greater with the CS 3000 and Fresenius separators.

Conclusion

Although a significant drop in complete blood count was observed in all donors, none manifested features of thrombocytopenia or anaemia. Nevertheless, more prospective studies on this aspect are required in order to establish guidelines for donor safety in apheresis and also to help in assessing donor suitability, especially given the present trend of double product apheresis collections.  相似文献   

7.
We evaluated assays of the same fresh blood samples with six different types of reference automated hematology analyzers developed by the following manufacturers: Beckman Coulter, Sysmex, Bayer, Abbott, Nihon Kohden and Horiba. Fresh whole blood samples treated with dipotassium ethylenediaminetetraacetic acid (EDTA K2) were collected from three healthy adult volunteers. The complete blood counts (CBC) including red blood cell count (RBC), hemoglobin (Hgb), hematocrit (Hct), mean corpuscular volume (MCV), white blood cell count (WBC), platelet count (Plt), reticulocyte percentage (Ret) and leukocyte differential counts including % neutrophils (Neu), % lymphocytes (Lym) and % monocytes (Mon) were surveyed with a reference automated hematology analyzer from each manufacturer. The process from sampling to analysis was performed according to procedures in hospital clinical laboratories. RBC, Hgb, Hct and MCV exhibited allowable differences within 5% of mean value among all instruments. Large differences greater than 10% of mean value in WBC, Neu and Lym between Horiba and other manufacturers, and in Plt between Nihon Kohden and other manufacturers, were observed. Ret and Mon exhibited large differences over 10% of mean value among almost all of the instruments tested. This survey suggests that all parameters exhibiting differences greater than 10% of mean value among instruments should be improved for clinical use to ensure good external quality control in blood cell counting and leukocyte differential counting using automated instruments.  相似文献   

8.
Summary A longitudinal study of normal hematological values of the newborn infant was undertaken in an effort to provide baseline data for assessing the African Neonate with hematological problems. There were 402 neonates, consisting of 304 full-term, 51 preterm and 47 post-term infants. The Hematocrit (Hct), Hemoglobin (Hb), Red Blood Cell Count (RBC), Reticulocyte count (Retic) and Nucleated Red Blood Cell Count (NRBC) were serially determined. The red cell indices, Mean corpuscular Hemoglobin (MCH), Mean Corpuscular volume (MCV) and Mean corpuscular Hemoglobin Concentration (MCHC) were calculated for each neonate. Our results showed that African neonates have lower hematological values than their North American and European counterparts. This was neither a reflection of an intrauterine anemia nor was it due to variables resulting from the timing of cord blood sampling. On the first day of life, the mean Hct was 45.4%; mean Hb was 15.46 gm/dl; and the RBC was 4.02×106 cells/mm2. The Retics, NRBC and other red blood cell indices do not differ from those of neonates reported from other parts of the world. We suggest therefore that the low hematological values of the African neonate may be intrinsic.  相似文献   

9.
The objective of this study was to establish haematological reference ranges for the West African subregion using a Gambian cohort. We analysed full blood counts from 1279 subjects aged > or =1 year. Anthropometric and body composition measurements were performed. Haematological mean values, medians and 90% reference values were calculated and related to malnutrition in children and thinness and/or obesity in adults. Haemoglobin (Hb) and mean corpuscular volume (MCV) significantly increased with age (P < 0.00001). There were gender-related changes in Hb from 15 years of age (P = 0.001) and for MCV only in adults (P = 0.0002). Hb was significantly reduced in underweight and stunted children (P = 0.0001 and 0.0002, respectively) but was unaffected by thinness or obesity in adults. White blood cell (WBC) and platelet counts were highest under 5 years and declined significantly with age (P < 0.0001 and 0.0001). While, there were no gender-related differences with WBC, there were higher WBC counts in underweight (P = 0.0001) and stunted (P < 0.0001) children. Adult females had significantly higher mean platelet counts compared with males (P = 0.006). The mean and median values of haematological parameters in The Gambia are similar to other standards but the 90% reference range for each parameter encompasses lower values when compared with Western standards.  相似文献   

10.
Venous and skin puncture blood counts compared   总被引:1,自引:0,他引:1  
Venous and skin puncture blood counts were compared in 80 paired samples from 33 children, aged 6 months to 14 years, and 10 adults. Significantly higher mean values for Hb, RBC, haematocrit and neutrophils were found in skin puncture blood in children whereas platelet values were slightly higher in venous blood. Similar results were found in adult samples. Only occasionally were differences likely to be of clinical importance. The excellent comparability of paired platelet counts, at variance to that found in some previous studies, indicates that skin puncture blood can be used for platelet estimation providing an appropriate counting method is used.  相似文献   

11.
Prolonged venous stasis, as generated by a long tourniquet placement, produces spurious variations in several measurable analytes. To verify to what extent venous stasis influences routine hematologic testing, we assessed routine hematologic parameters, including hemoglobin, hematocrit, red blood cell count (RBC), main cell hemoglobin (MHC), main cell volume (MCV), platelet count (PLT), main platelet volume (MPV), white blood cell count (WBC) and WBC differential on the Advia 120 automated hematology analyzer in 30 healthy volunteers, either without venous stasis (no stasis) or after application of a 60 mmHg standardized external pressure by a sphygmomanometer, for 1 (1-min stasis) and 3 min (3-min stasis). Although the overall correlation between measures was globally acceptable, the mean values for paired samples were significantly different in all parameters tested, except MCV, MHC, PLT, MPV, eosinophils, basophils and large unstained cells after 1-min stasis and all parameters except MCV, MHC, MPV and basophils after 3-min venous stasis. As expected RBC, hemoglobin and hematocrit displayed a significant trend towards increase, whereas WBC and the WBC subpopulations were decreased. Difference between measurements by Bland and Altman plots exceeded the current analytical quality specifications for desirable bias for WBC, RBC, hemoglobin, hematocrit, lymphocytes and monocytes in samples collected after either 1- and 3-min stasis. These results provide clear evidence that venous stasis during venipuncture might produce spurious and clinically meaningful biases in the measurement of several hematologic parameters, prompting further considerations on the usefulness of adopting appropriate preventive measures for minimizing such influences.  相似文献   

12.
Blood hyperviscosity due to secondary erythrocytosis is a common pathologic feature of cyanotic congenital heart disease (CCHD). In CCHD, it is possible that hematological parameters other than red blood cells influence blood rheology. We measured blood passage time to evaluate the blood rheology in patients with CCHD (n=18, age: 15.3+/-11.9 years, mean +/- SD) and age-matched control subjects (n=27) using the microchannel array flow analyzer (MC-FAN), and the results [several hematological parameters, including hematocrit (Hct)] were compared. Blood passage time in the CCHD group was prolonged, compared with the control group (67.6+/-27.2 s vs. 44.6+/-6.7 s). For the CCHD group, blood passage time correlated significantly with red blood cell (RBC) count, hemoglobin (Hb) concentration, Hct, mean corpuscular hemoglobin concentration (MCHC), platelet (Plt) count, high-density lipoprotein cholesterol (HDL-C) level, and triglycerides (TG) level (RBC, r=0.77; Hb, r=0.69; Hct, r=0.73; MCHC, r=-0.64; Plt, r=-0.49; TG, r=0.53; HDL-C, r=-0.49, p<0.05 for each variable). For all 45 subjects, blood passage time correlated significantly with HbA1c level (r=0.45, p<0.01) and tissue-type plasminogen activator (t-PA) antigen level (r=0.46, p<0.01). Our results indicated that blood rheology is reduced in patients with CCHD as expressed by prolonged blood passage time, and it may be defined by several blood parameters in addition to erythrocytosis.  相似文献   

13.
Haematology analysers provide quick and accurate results in most situations. However, spurious results, related either to platelets (part I of this report) or to other parameters from the cell blood count (CBC) may be observed in several instances. Spuriously low white blood cell (WBC) counts may be observed because of agglutination in the presence of ethylenediamine tetra-acetic acid (EDTA). Cryoglobulins, lipids, insufficiently lysed red blood cells (RBC), erythroblasts and platelet aggregates are common situations increasing WBC counts. In most of these instances flagging and/or an abnormal WBC differential scattergram will alert the operator. Several situations lead to abnormal haemoglobin measurement or to abnormal RBC count, including lipids, agglutinins, cryoglobulins and elevated WBC counts. Mean (red) cell volume (MCV) may be also subject to spurious determination, because of agglutinins, excess of glucose or salts and technological considerations. In turn, abnormality related to one measured parameter will lead to abnormal calculated RBC indices: mean cell haemoglobin content (MCHC) is certainly the most important RBC indices to consider, as it is as important as flags generated by the haematology analysers (HA) in alerting the user to a spurious result. In many circumstances, several of the measured parameters from CBC may be altered, and the discovery of a spurious change on one parameter frequently means that the validity of other parameters should be considered. Sensitive flags now allow the identification of several spurious counts, but only the most sophisticated HA have optimal flagging and more simple HA, especially those without a WBC differential scattergram, do not possess the same sensitivity for detecting anomalous results. Reticulocytes are integrated now into the CBC in many HA, and several situations may lead to abnormal counts.  相似文献   

14.
The Sysmex SE-9c500 is a new, fully automated haematology analyser, providing a complete blood count (CBC), including a five-part differential count (DC), with flagging of morphological abnormalities. The SE-9500 was evaluated according to guidelines published by the International Committee for Standardisation in Haematology (ICSH). The results demonstrated minimal carryover (< 0.01%) and excellent linearity for WBC, RBC, HGB and platelet (PLT) (r > 0.995). Samples were stable with regard to CBC parameters after storage for up to 48 h at room temperature (RT) and 4 degrees C. Imprecision was generally acceptable for all CBC parameters (CV < 5%). Correlation between the SE-9500 and reference methods was excellent (r > 0.97) for all the major CBC parameters (WBC, RBC, HGB, PLT). There was minimal interference for WBC, RBC, HGB and PLT at high concentrations of bilirubin (BIL=224 micromol/l) or triglyceride (TG=7.78 mmol/l). SE-9500 reference values for CBC parameters are presented. Our results indicate that the SE-9500 is an excellent tool for routine haematological examination.  相似文献   

15.
Epidemiologic studies have suggested a relation between white blood cell (WBC) counts and the incidence of coronary heart disease. However, the relation between vasospastic angina pectoris (VAP) and WBC counts remains to be elucidated. To clarify the relation between differential and WBC counts in VAP, we compared the hematologic values, blood chemical values, plasma fibrinogen levels, C-reactive protein levels, and coronary risk factors in patients with spontaneous attacks of VAP (n = 39) with those in patients with stable effort angina pectoris (EAP, n = 35) and in control subjects (n = 19). Patients with VAP were further divided into mild VAP (n = 22) and severe VAP groups (n = 17). There were no differences in the coronary risk factors, body temperature, total WBC counts, and C-reactive protein levels among the control, EAP, mild VAP, and severe VAP groups, except that the high-density lipoprotein cholesterol in the EAP group was significantly lower than that in the control group (p <0.01). In contrast, the eosinophil counts were significantly higher in the severe VAP group than in the other 3 groups (p <0.01). Plasma fibrinogen levels were also significantly higher in the severe VAP group than in the other 3 groups (p <0.05). The follow-up study for differential and WBC counts in patients with VAP (n = 23) demonstrated that, after medical therapy, the eosinophil counts were significantly decreased to the some level as those in the control group (p <0.0001). Thus, the eosinophil counts and plasma fibrinogen levels could predict the severity of VAP. Furthermore, a follow-up study in patients with VAP suggests that coronary vasospasm could result in an increase in eosinophil counts.  相似文献   

16.
The Sysmex SE‐9c500 is a new, fully automated haematology analyser, providing a complete blood count (CBC), including a five‐part differential count (DC), with flagging of morphological abnormalities. The SE‐9500 was evaluated according to guidelines published by the International Committee for Standardisation in Haematology (ICSH). The results demonstrated minimal carryover (< 0.01%) and excellent linearity for WBC, RBC, HGB and platelet (PLT) (r > 0.995). Samples were stable with regard to CBC parameters after storage for up to 48 h at room temperature (RT) and 4 °C. Imprecision was generally acceptable for all CBC parameters (CV < 5%). Correlation between the SE‐9500 and reference methods was excellent (r > 0.97) for all the major CBC parameters (WBC, RBC, HGB, PLT). There was minimal interference for WBC, RBC, HGB and PLT at high concentrations of bilirubin (BIL=224 μmol/l) or triglyceride (TG=7.78 mmol/l). SE‐9500 reference values for CBC parameters are presented. Our results indicate that the SE‐9500 is an excellent tool for routine haematological examination.  相似文献   

17.
In this work we studied platelet adhesion to subendothelial surfaces in 10 patients with polycythaemia vera and 10 healthy volunteers at 40% Hct (corresponding to the mean value of our control group) and 55% Hct (a value roughly corresponding to the mean Hct in polycythaemic patients). Platelet concentration was kept constant at 2.0-2.5 X 10(11)/l. The results indicate that there was a statistically significant increase in adhesion both in controls and in patients with Hct varying from 40% to 55%. The contribution of the higher Hct in promoting platelet adhesion was comparable in the two groups. When red blood cells (RBC) from the patients were tested with platelets from healthy volunteers in cross-over experiments, they promoted adhesion in the same way as control RBC. Similarly, when patients' platelets were mixed with control RBC, adhesion was the same as control platelets. These data indicate that platelet and RBC contribution to this parameter are not significantly modified in this group of polycythaemic patients, provided that platelet and RBC values are adjusted to control range.  相似文献   

18.
Conditions during coronary artery bypass grafting (CABG) performed on beating heart (off-pump) are more physiological than using extracorporeal perfusion (on-pump). The present study aims to examine the hemorheological aspects of the two techniques. Blood samples were taken from patients undergoing on-pump (n = 25) and off-pump (n = 22) CABG, upon arrival to the operating theatre, after 20 and 40 minutes during the operation, after closing the thorax, on the 1st and 2nd postoperative days, and during the 2nd and 6th month control check-ups. Hematocrit (Hct), plasma and whole blood viscosity (PV, WBV; Hevimet 40 capillary viscometer), red blood cell (RBC) aggregation (Myrenne RBC aggregometer, LORCA) and deformability (LORCA, Carat FT-1 filtrometer), and platelet aggregation (Carat TX4 aggregometer) were determined. The morphology of red blood cells was investigated by scanning electron microscopy (SEM). Hct, PV, WBV and RBC aggregation decreased significantly during the early phase of the surgery, they started to recover during the postoperative period, and reached the baseline values by the 2nd and 6th month control check-ups. These parameters were significantly lower in samples taken after 20 and 40 minutes in the on-pump group. SEM showed rather damaged and malformed cells in case of on-pump surgery. Ektacytometry showed no significant difference, but RBC deformability was impaired during on-pump surgery when measured by filtrometry. The decrease in platelet aggregation was more pronounced by the end of surgery in case of on-pump technique. During CABG rheological parameters change less when using the off-pump method, and mechanical damage of RBCs are also smaller. The off-pump technique seems to be favorable from a hemorhelogical point of view.  相似文献   

19.
long-term peripheral blood counts and factors influencing long-term trilineage haematological recovery of consecutive patients in a single institution treated with high-dose chemotherapy (hdc) and abmt or psct for solid tumours were examined. patients with a relapse-free survival of >1 year were included in the analysis (n = 131). Peripheral blood counts were examined 6 months and yearly following transplantation. Median follow-up was 4.1 years (range 1-10+ years). Three years after transplantation 91% of patients had normal white blood counts (WBC), 94% normal haemoglobin (Hb) and 75% normal platelets. Trilineage recovery was complete in 70% (n = 83) at 3 years and 85% (n = 50) at 5 years. Recovery of Hb occurred before WBC and platelet recovery. Approximately 25% of patients displayed an elevated MCV throughout the follow-up period. These long-term results were independent of age, high-dose regimen, number of reinfused stem cells and stem cell source. Double (n = 12) vs single (n = 119) transplantations showed significantly slower trilineage recovery and higher MCV. No secondary graft failure, myelodysplasia or leukaemia was encountered. In conclusion, complete trilineage recovery after HDC followed by ABMT or PSCT occurs slowly. PSCT and ABMT are capable of maintaining long-term haematopoiesis. Slower recovery is seen after double transplantations. The results suggest lasting implications for bone marrow function after autologous transplantation.  相似文献   

20.
AimTo estimate the blood level of Erythropoietin(EPO) in neonates with anemia of prematurity (APO) and in late hypo-regenerative anemia and to clarify role of EPO in correction of anemia and reducing the number of blood transfusions.MethodsThis study was carried out on 60 neonates divided into; group I (30 preterm neonates) with AOP received EPO (250 IU/kg/dose subcutaneously 3 times weekly for 4 weeks), compared to group II (30 neonates) with AOP treated only with blood transfusion. CBC parameters and transfusion requirements were followed during therapy. Serum level of EPO was measured by ELISA technique.ResultsBy the end of the 4th week of therapy, there was significant increase in group I post r-Hu EPO compared to group II regarding reticulocyte counts (P < 0.001) leading to rise of the Hb (P < 0.001), Hct levels (P < 0.001) with subsequent reduction in the overall number of blood transfusions (P < 0.001).ConclusionEPO therapy in conjunction with iron, vitamin E and folic acid, stimulated erythropoiesis and significantly reduced the need for blood transfusion in AOP.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号