首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 468 毫秒
1.
目的 评估双能量CT肺动脉成像(CTPA)上不同能量图像的图像质量,以确定双能量CTPA的最佳能量混合方式.方法 装满不同浓度碘水的模型及27例怀疑肺动脉栓塞的患者行胸部双能量CT扫描,将140kV和80kV图像传送至后处理工作站,按照不同的能量比例混合生成9种权重因子的混合能量图像.比较140kV图像、9种不同权重因子混合能量图像和80kV图像上模型内碘水的CT值、噪声和信噪比(SNR),同时比较27例患者140kV图像、9种混合能量图像和80kV图像上肺动脉的CT值、噪声、SNR和对比噪声比(CNR),并对所有患者的权重因子为0.3的混合能量图像、80kV图像和最佳混合能量图像的肺动脉图像质量进行评分.结果 在实验研究及临床应用中,权重因子为0.3的混合能量图像噪声均最小,而权重因子为0.5的混合能量图像肺动脉的SNR值最大,其次为权重因子为0.6的混合能量图像,临床应用中权重因子为0.5和0.6的混合能量图像上肺动脉的CNR值最大.权重因子为0.3、0.5、0.6的混合能量图像和80kV图像的评分结果总体比较,差异有统计学意义(x2 =25.65,P=0.00),其中权重因子为0.6的混合能量图像评分最高.结论 双能量CTPA中,权重因子为0.5和0.6的混合能量图像能提供最佳肺动脉SNR和CNR,并能够提高CTPA的图像质量.  相似文献   

2.
目的 探讨双源CT(DSCT)双能量扫描对肝脏病变的诊断价值及限度.方法 将53例B超拟诊肝脏占位患者行上腹部普通平扫(TNE)及三期增强扫描(动脉期、双能量门静脉、延迟期).双能量扫描后自动生成80 kV、140 kV以及120 kV加权图像.数据导入工作站的虚拟平扫(VNE).从图像定性评估(肿瘤可见度、图像噪声、诊断接受度)及定量数值(脏器平均CT值、图像噪声、对比噪声比)比较VNE与TNE的图像质量;判断VNE能否取代TVE、80 kV图像中病变的微小血供、双能量纯(彩)碘图、以及感兴趣区(ROI)分解CT值的诊断作用.最后,对比TNE与VNE的有效辐射剂量.结果 53例中有7例在80 kV中较140 kV及120 kV加权图像更清晰显示肿瘤内血管.VNE肿瘤可见度、诊断接受性显著低于、噪声显著高于TNE(P<0.05).TNE及VNE平均CT值分别为:肝实质(58.5±5.6) HU、(58.2±6.7) HU(P=0.226);肝占位(38.8±8.1) HU、(37.4±8.3) HU(P<0.05).VNE图像噪声及对比噪声比显著高于TNE(P<0.001).超出的肝边缘及伪影对诊断无影响,除4例外,VNE均能取代TVE.纯(彩)碘图直观展示病变血供范围及程度,ROI可分解平扫及碘增强的CT值.TNE与VNE有效剂量:(3.38±0.55) mSv,(3.36±0.90) mSv(P>0.05).结论 双源CT双能量80 kV较常规CT对病变血供更敏感,其后处理功能对病变定性诊断有一定作用.VNE图像质量较TNE差,但可取代之并减少辐射剂量.  相似文献   

3.
目的探讨炫速双源CT非线性融合技术对超重或肥胖患者心脏CT成像质量的优化价值。方法 36位体质指数处于超重或肥胖的患者行双能量心脏增强扫描,每一位患者重建4组图像,A组:NLB1(λ=150HU,ω=200HU),B组:NLB2(λ=70HU,ω=200HU),C组:NLB3(λ=260HU,ω=200HU),D组:NLB4(λ=260HU,ω=400HU),测量并计算上述图像主动脉根部、右冠状动脉中段、左冠状动脉主干和左心室前壁的CT值、图像噪声、SNR、CNR。采用TWO-WAY ANOVA及TUKEY检验客观评价各组图像质量。结果 4组图像间除心肌CT值无统计学差异外(F=2.492,P=0.064),余各部位CT值、噪声、SNR、CNR均具有统计学差异(P0.05)。各血管CT值B组最高,与A组均无统计学差异。各血管噪声B组最小,与A组无统计学差异。心肌噪声C组最小,与A组无统计学差异。各血管SNR A、B组较高,两组无统计学差异。心肌SNR以A、C、D组较大,与B组有统计学差异。各血管均以D组SNR最小。心肌SNR B组最小。所有CNR均以A组最高,与B组无统计学差异,D组最小。结论非线性融合技术选择合适的融合参数(λ=150HU,ω=200HU)既可以提升超重或肥胖患者冠状动脉的强化效果又可以抑制冠状动脉及心肌噪声,进一步提高心脏CT成像的CNR。  相似文献   

4.
目的 分析双源CT(dual-source CT,DSCT) 80 kV管电压冠状动脉成像的图像质量,探讨80 kV管电压扫描对减少冠状动脉CTA检查辐射剂量的价值.方法 60例行DSCT冠状动脉造影患者,体重指数(body mass index,BMI) <24.9 kg/m2,随机分成80 kV、362 mAs及100 kV、362 mAs两组,每组30例.对两组的图像质量、平均CT值、图像噪声、信号噪声比(signal-to-noise ratio,SNR)、对比噪声比(contrast-to-noise ratio,CNR)及辐射剂量进行对比分析.结果 两组图像质量评分分别为(3.29±0.82)分和(3.43±0.53)分,差异无统计学意义(P>0.05);80 kV组平均CT值(752.2±156.2) HU高于100 kV组(573.6±115.2) HU,差异有统计学意义(P<0.05);80 kV组图像噪声高于100 kV组,差异有统计学意义(P <0.05);80 kV组SNR和CNR略低于100 kV组,但差异无统计学意义(P >0.05);80 kV、100kV组有效辐射剂量分别为(2.80±1.53) mSv和(7.29±1.36) mSv,差异有统计学意义(P<0.05).结论 对于BMI在正常范围内的患者,采用80 kV管电压冠状动脉CTA检查,可在保证图像质量的同时显著降低辐射剂量.  相似文献   

5.
目的:寻找CT能谱成像的最佳能量点以减少肺部增强CT扫描锁骨下腋静脉和锁骨下静脉对比剂伪影,并改善图像质量。方法:共66名病人接受能谱CT扫描。一次能谱成像获得12组图像:140kVp混合能量图像和11组单能量图像(40~140keV)。比较混合能量和单能量图像在肺部增强CT动脉期的伪影区噪声、信噪比(SNR)、对比噪声比(CNR)和平均线束硬化伪影指数(BHAs)。BHAs是感兴趣区和背景区噪声平方差的平方根。结果:与常规混合能量组相比,120keV可最大程度地减少硬化伪影(P=0.000),同时SNR、CNR明显减小,导致软组织对比度明显减低。70keV可以减小硬化伪影(P=0.042),且SNR、CNR最高,优于混合能量图像和其他单能量图像,而伪影区噪声减低,图像质量最好。结论:在肺部增强扫描中,120keV去除对比剂硬化伪影的能力优于混合能量图像及其他单能量图像,但是组织对比度较差,可以结合70keV图像共同进行诊断。  相似文献   

6.
目的:探讨双层探测器光谱CT显示左结肠动脉(LCA)的最佳虚拟单能量,旨在为腹腔镜直肠癌根治术前评估LCA提供帮助。方法:回顾性分析在本院行腹部CT血管成像(CTA)扫描的100例患者的影像学资料,将动脉期原始图像重组成混合能量图像以及基于能谱的间隔10 keV的40~70 keV的单能量图像。对5组图像LCA的CT值、信噪比(SNR)、对比噪声比(CNR)、图像噪声以及图像质量评分进行比较。结果:40~70 keV组单能量图像LCA的CT值、噪声、CNR、SNR随着能级的升高呈递减趋势。常规混合能量图像组及40~70 keV单能量图像组两两比较,各组间CT值、SNR、CNR、噪声差异有统计学意义(P<0.05)。40 keV组图像LCA的CT值、CNR、SNR均高于其他组,噪声低于常规混合能量图像组。两名影像科医师图像质量主观评价的一致性良好(0.40≤Kappa值<0.75),各组间图像主观评分差异均有统计学意义(P均<0.001)。40 keV组图像主观评分最高,40~70 keV组单能量图像质量均高于常规混合能量图像。结论:40 keV为显示LCA的最佳虚拟单...  相似文献   

7.
目的 研究利用盆腔迭代锥形束CT(CBCT)图像用于治疗计划剂量计算的可行性分析,为自适应放疗提供图像保障。方法 使用Varian Halcyon 2.0环形加速器对CIRS 062 M模体(CIRS,Norfolk,VA,USA)进行扫描,测量其不同散射条件下的CT值并计算其平均值,建立锥形束CT-电子密度转换曲线(iterative Cone-beam CT to electron density,ICBCT-ED)。采集CIRS 002PRA盆腔调强专用模体的CT和不同位置的ICBCT图像,设计基于CT图像的VMAT计划,移植至ICBCT图像上,重新进行剂量计算,比较靶区、危及器官及三维体积剂量γ通过率的差异。以患者实际治疗计划为基准,回顾性分析10例盆腔患者全流程三维剂量γ通过率的差异。结果 无散射体的孤立模式与全散射中心位置的CT值偏差较大,最大偏差144 HU。其他全散射位置与中心位置CT值相近,最大偏差<50 HU。基于盆腔模体不同位置处的ICBCT图像的计算结果,无论靶区还是危及器官的剂量偏差均<1 Gy。与基于CT图像的计划相比,基于ICBCT图像的三维剂量γ通过率1%/1 mm和2%/2 mm的平均值分别为(88.86±1.18)%和(98.38±0.89)%。10例盆腔肿瘤患者2%/2 mm和3%/3 mm的平均值范围分别为90.03%~95.43%和93.58%~97.78%。最差结果为膀胱过充盈引起的外轮廓变化造成的剂量差异,2%/2 mm和3%/3 mm的三维剂量通过率仅为85.90%和92.90%。结论 在足够的散射条件下,重建ICBCT-ED转换曲线,利用Halcyon直线加速器的ICBCT图像进行治疗计划设计,其精度是可以满足临床应用的标准的,为将来的自适应放疗提供了保障。  相似文献   

8.
目的:探讨低浓度等渗对比剂联合应用80 kV 和自适应统计迭代重建(ASiR)技术,对支气管动脉(BA)CT 血管成像(CTA)的价值。方法随机选取本院40例欲行 CT 增强检查的肺癌患者,18.5 kg/m2≤体质量指数(BMI)≤25 kg/m2。随机分为80 kV、260 mA 及120 kV、150 mA 2组,每组20例,其中80 kV 组为低浓度等渗对比剂(Visipaque 270 mg I/mL),50% ASiR;120 kV 组为高浓度对比剂(Ultravist 370 mg I/mL),滤波反投影(FBP)。比较2组中 BA 的 CT 值、图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)及有效辐射剂量(ED)。所得结果应用 SPSS 17.0软件采用独立样本 t 检验两两比较,P <0.05有统计学意义。结果80 kV 组的 CT 值(317.33 HU±70.44 HU)高于120 kV 组(256.39 HU±37.38 HU),差异有统计学意义(P <0.05);80 kV 组 SD、ED 及剂量长度乘积(DLP)[SD (7.55±1.51)HU;ED (1.74±0.14)mSv;DLP (124.94±9.9)mGy/cm]低于120 kV 组[SD (9.36±1.26)HU;ED (3.20±0.35)mSv;DLP (228.82±25.13)mGy/cm],差异有统计学意义(P<0.05);80 kV 组的 CNR 和 SNR(CNR 59.71±17.36;SNR 44.01±14.71)均优于120 kV 组(CNR 37.61±6.16;SNR 27.75±4.72),差异有统计学意义(P <0.05)。80 kV 组图像质量主观评分(3.73±0.66)略低于120 kV 组(3.81±0.59),但差异无统计学意义(t =-0.558,P >0.05)。结论对于 BMI 在正常范围内的患者,采用低浓度等渗对比剂联合80 kV 和 ASiR 技术行 BA CTA 检查,可在保证 BA 图像质量的同时显著降低有效辐射剂量47%,降低碘用量27%。  相似文献   

9.
目的 通过对肺结节模型进行宝石能谱成像(gemstone spectral imaging,GSI)扫描,探讨单能成像在肺结节CT值准确测量中的价值.方法 制作3个直径为20 mm的球体模拟肺结节,结节分别由3种密度不同的物质制成(聚丙烯,尼龙,腈纶),相应CT值分别为-100 HU、60 HU、100 HU.结节固定在塑料肺基底模型(-900 HU)内,周围加基液或基液加动物骨骼以改变模型周围环境.Discovery CT750 HD能谱CT对肺结节模型进行GSI扫描和常规扫描(混合能量).GSI扫描参数:140 kV/80 kV瞬时切换;630 mA;层厚64×0.625 mm;螺距0.5161;SFOV 50 cm;DFOV 38 cm.常规扫描管电压120 kV,管电流(mA)根据GSI扫描患者的CT剂量指数确定,其他扫描参数与GSI扫描一致.3位经验丰富的影像学医师独立测量不同扫描条件下结节的CT值及标准差值.混合能量和单能条件下所得结节的CT值及相应的图像信噪比(SNR)进行比较.结果 (1)分别在基液与基液+骨骼条件下对肺结节模型进行GSI扫描:所得CT值均无明显统计学差异(P>0.05).所有结节转速为0.8 s/r及60 HU结节转速为1.0 s/r时SNR无明显统计学差异(P>0.05);其他条件下SNR间差别有统计学意义(P<0.05).(2)分别在基液与基液+骨骼条件下对肺结节模型进行常规扫描:所得CT值间差别有统计学意义(P<0.05).所有SNR间差别亦有统计学意义(P<0.05).结论 GSI扫描可有效减除硬化伪影对CT值的影响得到较常规扫描更准确的肺结节CT值;相应SNR亦较常规扫描趋于稳定.  相似文献   

10.
帅桃  李真林  阳琴  赵利娜  袁元  陈国勇  张凯   《放射学实践》2013,(12):1196-1199
目的:探讨双源CT能谱纯化技术在CT泌尿系虚拟平扫成像中的应用价值。方法:80例患者随机均分为两组行泌尿系CT扫描,A组采用一代双源CT扫描(140kV/80kV组),B组采用二代双源CT扫描(80kV/Sn 140kV组),两组间在增强扫描动脉期采用双能量扫描的方式,其余期相均采用单源扫描。将两组双能量扫描图像通过软件处理获得虚拟平扫图像。比较两组虚拟平扫图像的CT值、信噪比及噪声,并与常规平扫图像比较病灶的检出情况。结果:B组的图像噪声低于A组,信噪比高于A组;与140kV/80kV组比较,80kV/Sn 140kV组虚拟平扫提高了对小结石(直径<4mm)的显示能力;双能量扫描辐射剂量,80kV/Sn 140kV组比140kV/80kV组低约10%。结论:能谱纯化技术可明显提高对物质的识别能力,提高虚拟平扫的图像质量,真正达到减少扫描次数、降低患者辐射剂量的目的。  相似文献   

11.
目的 探讨加速器成像射束影像系统(IBL)的全扇形束和大射野(EFOV)两种模式扫描得到的兆伏级锥形束断层(MV CBCT)图像可否用于剂量计算。方法 利用大孔径CT和在IBL的全扇形束和EFOV模式下对CIRS 062M型电子密度模体进行扫描,在Pinnacle计划系统中分别建立电子密度曲线。用CT和加速器MV级CBCT模式扫描头颈、胸、腹盆腔部仿真模体,利用CT图像制作调强计划,并将计划移植于MV CBCT的图像中,利用相应的电子密度曲线计算剂量,比较靶区及危及器官剂量分布。结果 MV CBCT图像中剂量分布比参考计划剂量偏低,并且在头颈、胸、腹盆腔模体中偏差依次增大。与参考计划相比,头颈部靶区剂量和危及器官剂量分布一致,偏差均在3%以内。胸部和腹盆腔靶区和危及器官的剂量分布均有大幅度的降低,偏差分别达到5%和10%,超出了临床接受范围。结论 在加速器IBL中全扇形束模式条件下,头颈部患者扫描得到的MV CBCT图像可在自适应放疗中用于剂量计算,胸、腹盆腔部位在EFOV模式下仅可用于图像引导,不能用于剂量计算。  相似文献   

12.
Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy? system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to ~2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.  相似文献   

13.
目的 探讨在粒子植入过程中降低扫描条件进行手术的可行性。方法 使用GE Lightspeed RT大孔径CT,分别使用120、100和80 kV,初始毫安数为150 mA,以20 mA的间隔递减至10 mA的扫描条件组合对GEMS模体和包含不同密度组织替代物的062 M模体进行扫描。对扫描剂量进行记录,测量图像感兴趣区的CT值、噪声值,计算信噪比(SNR)值和对比噪声比(CNR)值,评估图像质量,优化出较为适合的扫描条件。结果 随着管电压和管电流的降低,图像的信噪比降低。除120 kV,150~70 mA及100 kV,150~90 mA,其余条件下图像的SNR与标准图像差异有统计学意义(t=-12.710~3.717,P<0.05)。随着管电压和管电流的降低,对比度差异较小的相邻组织的对比噪声比显著降低,当对比噪声比降到2以下时,图像质量过低无法评估。降低管电压和管电流对CT图像的高对比分辨力影响不大。结论 综合实验结果,使用管电压100 kV,管电流70 mA的扫描条件进行扫描时,其图像质量接近标准参数扫描图像。在粒子植入过程中,除第1次扫描外使用标准胸部扫描条件外,其余在反复扫描同一区域时可降低条件至100 kV,70 mA进行扫描,可使患者每次扫描接受的辐射剂量大幅下降。  相似文献   

14.
目的 检测并分析电子射野影像系统( EPID)、kV级平面摄像(kV planar)、kV级锥形束CT( CBCT)3种图像模式在影像引导放疗(IGRT)中摆位误差的精度.方法 通过在计划系统的模体CT图像上模拟25组摆位偏差,生成25组DRR参考图像和25组三维CT参考图像,分别与模体在原点位置获取的EPID,kV planar和CBCT 3种图像模式进行图像配准和摆位误差的测量,检测并比较3种图像模式在摆位误差测量中的精度.结果 共读取675组残留误差,3种图像及其相应的配准方法均具有较高的精确度,残留误差的平均值在x、y、z方向上均<1 mm,CBCT的灰度值配准精度<0.1 mm,kV planar图像在手动配准时其测量摆位误差的精度好于EPID(<0.65 mm),在自动配准方法时与EPID具有同等的精度.结论 医院IGRT系统的3种图像模式及其相应的配准方法均可以满足临床应用,CBCT为首选,结合图像质量、成像剂量和配准精度等因素,kV planar优于EPID.  相似文献   

15.
Objective:To evaluate the value of using low energy (keV) images in renal dual-energy spectral CT angiography (CTA) and adaptive statistical iterative reconstruction (ASIR) to reduce contrast medium dose.Methods:40 patients with renal CTA on a Discovery CT750HD were randomly divided into two groups: 20 cases (Group A) with 600 mgI kg−1 and 20 cases (Group B) with 300 mgI kg−1. The scan protocol for both groups was: dual-energy mode with mA selection for noise index of 10 HU, pitch 1.375:1, rotating speed 0.6 s/r. Images were reconstructed at 0.625 mm thickness with 40%ASIR, Group A used the conventional 70keV monochromatic images, and Group B used monochromatic images from 40 to 70 keV at 5 keV interval for analysis. The CT values and standard deviation (SD) values of the renal artery and erector spine in the plain and arterial phases were measured with the erector spine SD value representing image noise. The enhancement degree of the renal artery (ΔCT = CT(arterial) -CT(plain)), signal-to-noise ratio (SNR=CTrenal-artery/SDrenal-artery) and contrast-to-noise ratio (CNR=(CTrenal-artery-CTerector spine)/SDerector-spine) were calculated. The single factor analysis of variance was used to analyze the difference of ΔCT, SNR and CNR among image groups with p < 0.05 being statistically significant. The subjective image scores of the groups were assessed blindly by two experienced physicians using a 5-point system and the score consistency was compared by the κ test.Results:Contrast medium dose in the 300 mgI kg−1 group was reduced by 50% compared with the 600 mgI kg−1 group, while radiation dose was similar between the two groups. The subjective scores were 4.00 ± 0.65, 4.50 ± 0.60 and 3.70 ± 0.80 for images at 70 keV (600 mgI kg−1 group), 40 keV (300 mgI kg−1 group) and 45 keV (300 mgI kg−1 group), respectively with good consistency between the two reviewers (p > 0.05). The 40 keV images in the 300 mgI kg−1 group had similar ΔCT (469.77 ± 86.95 HU vs 398.54 ± 73.68 HU) and CNR (15.52 ± 3.32 vs 18.78 ± 6.71) values as the 70 keV images in the 600 mgI kg−1) group but higher SNR values (30.19 ± 4.41 vs 16.91 ± 11.12, p < 0,05)Conclusion:Contrast dose may be reduced by 50% while maintaining image quality by using lower energy images combined with ASIR in renal dual-energy CTA.Advances in knowledge:Combined with ASIR and energy spectrum, can reduce the amount of contrast dose in renal CTA.  相似文献   

16.
Objective:To determine the feasibility of using radiopaque (RO) beads as direct tumour surrogates for image-guided radiotherapy (IGRT) in patients with liver tumours after transarterial chemoembolisation (TACE).Methods:A novel vandetanib-eluting RO bead was delivered via TACE as part of a first-in-human clinical trial in patients with either hepatocellular carcinoma or liver metastases from colorectal cancer. Following TACE, patients underwent simulated radiotherapy imaging with four-dimensional computed tomography (4D-CT) and cone-beam CT (CBCT) imaging. RO beads were contoured using automated thresholding, and feasibility of matching between the simulated radiotherapy planning dataset (AVE-IP image from 4D data) and CBCT scans assessed. Additional kV, MV, helical CT and CBCT images of RO beads were obtained using an in-house phantom. Stability of RO bead position was assessed by comparing 4D-CT imaging to CT scans taken 6–20 days following TACE.Results:Eight patients were treated and 4D-CT and CBCT images acquired. RO beads were visible on 4D-CT and CBCT images in all cases and matching successfully performed. Differences in centre of mass of RO beads between CBCT and simulated radiotherapy planning scans (AVE-IP dataset) were 2.0 mm mediolaterally, 1.7 mm anteroposteriorally and 3.5 mm craniocaudally. RO beads in the phantom were visible on all imaging modalities assessed. RO bead position remained stable up to 29 days post TACE.Conclusion:RO beads are visible on IGRT imaging modalities, showing minimal artefact. They can be used for on-set matching with CBCT and remain stable over time.Advances in knowledge:The role of RO beads as fiducial markers for stereotactic liver radiotherapy is feasible and warrants further exploration as a combination therapy approach.  相似文献   

17.
目的:分析"直接分解"和"迭代分解"两种双能锥束CT(DECBCT)分解算法对于不同尺寸模体图像质量和物质分解精度的影响。方法:利用CatPhan604模体和定制套环组合,模拟不同尺寸的患者成像部位,在Edge加速器锥形束CT(CBCT)系统上分别获取高能140 kVp和低能100 kVp的CBCT,并分别利用两种算法...  相似文献   

18.
目的 分析千伏锥形束CT(kVCBCT)引导放疗系统可以发现的最小摆位误差和校正后剩余摆位误差。方法 采用小球(ball-bearing,BB)体模,比较经kVCBCT引导放疗系统得到的位移值与设定的位移值。设定的位移值分别为0.5、1.0、1.5和2.0 mm。侧向、纵向和垂直3个方向上的位移值均每日分析1次,共分析5次。校正后剩余摆位误差分析,采用CIRS Model 002LFC胸部体模,在侧向、纵向和垂直3个方向上均设置摆位误差,设置的数值为0、±5、±10和±15 mm。采用点标记法,共同配准体模的定位CT影像与kVCBCT影像,得出侧向、纵向和垂直3个方向上的摆位误差。根据配准结果移动治疗床,至侧向、纵向和垂直3个方向上摆位误差减少到最小。对校正位置后的体模再次行kVCBCT扫描,将再次获得的kVCBCT影像与定位CT采用点标记法配准,得到的侧向、纵向和垂直3个方向上的数值为经kVCBCT系统引导后剩余摆位误差。每日分析1次,共分析7次。结果 kVCBCT引导放疗系统可以发现的误差至少为0.5 mm。侧向、纵向和垂直3个方向上引导后剩余误差分别为(0.2±0.4)、(0.1±0.4)和(-0.4±0.3)mm,对3组数值行方差分析进行两两比较:侧向和纵向剩余误差无差别(P=0.63),垂直向和侧向剩余摆位误差的差异具有统计学意义(P=0.01),垂直向和纵向剩余摆位误差差异具有统计学意义(P=0.02)。结论 建立了kVCBCT引导放疗系统可以发现最小摆位误差和校正后剩余摆位误差的分析方法,kVCBCT引导放疗系统可以发现的误差至少为0.5 mm,侧向、纵向和垂直3个方向上引导后剩余误差约为1 mm。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号