首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundPoor implant positioning has been identified as a factor in early failure of unicompartmental knee arthroplasty. The aim of this study was to report the accuracy of component positioning, and midterm clinical, functional and radiological outcomes following patient-specific instrumented (PSI) unicompartmental knee arthroplasty (UKA).MethodsA total of 115 PSI-UKA were included. The primary outcomes were UKA survival, complication, and failure rates. Tibial implant positioning was determined using plain radiographs. Functional assessment included Oxford Knee Score (OKS), Forgotten Joint Score (FJS), patient satisfaction, and range of motion (ROM).ResultsThe survival rate of PSI-UKA was 92% after a mean follow-up of 55 months. The complication and failure rate was 13% and eight percent, respectively. The tibial component was accurately implanted in the desired frontal and sagittal alignment with a minor deviation of 0.3° (SD 1.9°) and 0.4° (SD 2.6°) to the preoperative planning. OKS increased from 24 (SD eight) points to 44 (SD six). FJS was 87 (SD 23) and 89.6% of all patients reported to be satisfied at the final follow-up. Patient satisfaction was negatively correlated with patients’ age (p < 0.05).ConclusionExcellent accuracy regarding component placement in UKA can be achieved with PSI. However, despite excellent survivorship and clinical outcomes, these data indicate that the PSI system is not superior to conventional UKA implantation methods.  相似文献   

2.
BackgroundSome studies have suggested that women have poorer short-term outcomes after unicompartmental knee arthroplasty (UKA) due to a higher incidence of implant overhang. This study aimed to compare patient-reported outcome measures (PROMs) between men and women after UKA at a minimum follow-up of 10 years.MethodsPatients who underwent medial fixed-bearing UKA by two arthroplasty surgeons were identified from an institutional joint registry. Men and women were matched for age, body mass index, Charlson Comorbidity Index, American Society of Anesthesiologists class, range-of-motion and baseline PROMs using propensity scores. PROMs were compared at 2 and 10 years. Patients also completed a satisfaction questionnaire during these visits. Radiographic outliers were defined as > 2 mm of overhang.ResultsA total of 128 patients were included. There was no difference in complications, length of stay or readmissions. Women had poorer Knee Society functional scores, Short-Form 36 physical and mental component scores (SF-36 MCS) at 2 years. No difference in PROMs was found at 10 years, except for poorer SF-36 MCS in women (P = 0.041). At 10 years, 96% of women and 92% of men were satisfied (P = 0.243). Fifteen-year survivorship free from any revision was 96% in each group. There were more medial-tibial outliers in women (9%) compared with men (5%) (P = 0.018). However, no association between outliers and outcomes or survivorship was found on multivariate analyses.ConclusionThere was no difference in clinical outcomes between men and women undergoing UKA at a minimum follow-up of 10 years. While women had a higher incidence of medial tibial overhang, this was not associated with long-term outcomes or survivorship.  相似文献   

3.
BackgroundLateral unicompartmental knee arthroplasty (UKA) leads to good clinical outcomes for isolated lateral osteoarthritis. However, the impact of the tibial component position on postoperative outcomes in lateral UKA is yet to be determined.PurposeThis study investigated the influence of tibial component malposition on clinical outcomes in lateral UKA.MaterialsThis was a retrospective study of 50 knees (mean age 73.5 years) who underwent lateral UKA between September 2013 and January 2019. The Oxford Knee Score (OKS), Knee Society Score – Knee (KSSK), and Knee Society Score – Function (KSSF) were evaluated. The coronal alignment, posterior slope of tibial component, tibial component rotation relative to Akagi’s line (angle α), and femoral anteroposterior (AP) axis (angle β) were measured postoperatively. The average follow up period was 2.3 (range, 1–4.9) years.ResultsClinical scores were significantly improved after lateral UKA. The mean coronal alignment was 0.9° ± 3.2° varus (range, 9.1° varus to 5.5° valgus), the mean posterior slope was 6.8° ± 3.8° (range, 0.8° to 14.8°). The mean α and β angles, were 4.1° ± 5.8° (range, −9.7° to 16.5°) and 6.7° ± 7.1° (range, −7.0° to 20.5°) external rotation. The angle α had significant negative correlations with postoperative OKS (r = −0.36), KSSK (r = −0.28), and KSSF (r = −0.39), and angle β had significant negative correlations with postoperative OKS (r = −0.34) and KSSK (r = −0.46).ConclusionExcessive external rotation of the tibial component could negatively influence the postoperative outcomes of lateral UKA.  相似文献   

4.

Background

Successful clinical outcomes following unicompartmental knee arthroplasty (UKA) depend on lower limb alignment, soft tissue balance and component positioning, which can be difficult to control using manual instrumentation. Although robotic-assisted surgery more reliably controls these surgical factors, studies assessing outcomes of robotic-assisted UKA are lacking. Therefore, a prospective multicenter study was performed to assess outcomes of robotic-assisted UKA.

Methods

A total of 1007 consecutive patients (1135 knees) underwent robotic-assisted medial UKA surgery from six surgeons at separate institutions between March 2009 and December 2011. All patients received a fixed-bearing metal-backed onlay implant as tibial component. Each patient was contacted at minimum two-year follow-up and asked a series of five questions to determine survivorship and patient satisfaction. Worst-case scenario analysis was performed whereby all patients were considered as revision when they declined participation in the study.

Results

Data was collected for 797 patients (909 knees) with average follow-up of 29.6 months (range: 22–52 months). At 2.5-years of follow-up, 11 knees were reported as revised, which resulted in a survivorship of 98.8%. Thirty-five patients declined participation in the study yielding a worst-case survivorship of 96.0%. Of all patients without revision, 92% was either very satisfied or satisfied with their knee function.

Conclusion

In this multicenter study, robotic-assisted UKA was found to have high survivorship and satisfaction rate at short-term follow-up. Prospective comparison studies with longer follow-up are necessary in order to compare survivorship and satisfaction rates of robotic-assisted UKA to conventional UKA and total knee arthroplasty.  相似文献   

5.
BackgroundJoint line orientation angle (JLOA) is the angle between the knee joint line and the floor. It has been reported to be related to postoperative outcome after TKA. Regarding unicompartmental knee arthroplasty (UKA), although it can be horizontal after UKA because it is a resurfacing surgery, there are few reports about the JLOA after UKA and its impact on clinical outcomes.PurposeThe purpose of this study was to reveal the relationship between JLOA and clinical outcome after UKA.MethodsThis study included 106 knees in 53 consecutive patients with osteoarthritis who underwent simultaneous bilateral mobile-bearing UKA. Their pre- and postoperative JLOAs were measured by full-leg-length standing coronal radiographs. We also evaluated the tibial component height (TCH) as the factor which we assumed could influence JLOA. We analyzed the patients’ JLOAs, TCHs and clinical outcomes.ResultsPre- and postoperative JLOA were 0.4 ± 2.4° and 2.7 ± 2.6°, respectively. The JLOA significantly tilted medially (P < 0.0001). The JLOA significantly negatively correlated with the improvement of the clinical outcomes (Oxford Knee Score (OKS): r = 0.40, P < 0.0001, Knee Society Knee Score (KSKS): r = 0.25, P < 0.01, Knee Society Function Score (KSFS): r = 0.22, P = 0.02). The TCH showed a positive correlation with postoperative JLOA and with the postoperative JLOA change (r = 0.45, P < 0.001; r = 0.25, P < 0.01, respectively).ConclusionThe JLOA significantly tilted medially after UKA. An excessive medial tilt of the JLOA was associated with poorer postoperative outcomes of UKA. It is therefore recommended to keep the JLOA horizontal and to avoid a lower tibial cut.  相似文献   

6.
BackgroundMinimal clinically important difference (MCID) is crucial for interpreting meaningful improvements in patient-reported outcome measures (PROMs). No previous study has evaluated the MCID for the Oxford Knee Score (OKS) in revision total knee arthroplasty (TKA). This study aimed to propose the OKS MCID for revision TKA.MethodsProspectively collected data from 191 patients who underwent revision TKA at a single institution was analysed. Clinical assessment was performed preoperatively and at 2 years using OKS and Short-Form 36 Physical Component Score (SF-36 PCS). MCID was evaluated with a three-pronged methodology, using (1) anchor-based method with linear regression, (2) anchor-based method with receiver operating characteristic (ROC) and area under curve (AUC), (3) distribution-based method with standard deviation (SD). The anchors used were improvement in SF-36 PCS ≥ 12, patient satisfaction, and implant survivorship following revision TKA.ResultsThe MCID determined by anchor-based linear regression method using improvements in SF-36 PCS was 4.9 points. The MCID determined by anchor-based ROC was 10.5 points for satisfaction (AUC = 74.8%) and 13.5 points for implant survivorship (AUC = 73.7%). The MCID determined by distribution-based method of 0.5 SD was 4.7.ConclusionThe proposed MCID for OKS following revision TKA is 4.9 points. Patients who achieve an improvement in OKS of at least 10.5–13.5 points by 2 years are likely to be satisfied with their surgery and not require a subsequent re-revision TKA. Patients undergoing revision TKA should aim for an improvement in OKS of at least 10.5–13.5 points as a target score.  相似文献   

7.
《The Knee》2020,27(3):1064-1070
BackgroundFemorotibial rotational mismatch has been reported to cause unsatisfactory outcomes after total knee arthroplasty. However, to our knowledge, no previous reports have described the relationship between the femorotibial rotational mismatch and clinical outcomes of Oxford unicompartmental knee arthroplasty (UKA).MethodsIn total, we studied 52 knees with primary varus knee osteoarthritis that underwent Oxford UKA with a navigation system. Tibial component internal rotation angles relative to the femoral component at extension and flexion angle of 90° were measured using a navigation system. We evaluated the relationship between the clinical outcomes and femorotibial rotational mismatch angles. Additionally, we evaluated the relationships between the outcomes and rotational alignments of the femur and tibial components measured by computed tomography (CT).ResultsThe tibial component internal rotational angle relative to the femoral component was significantly larger at a flexion angle of 90° than on extension (P < .001) and showed negative correlations with the Knee Society Functional Score and the pain and sports subscales of the Knee Injury and Osteoarthritis Outcome Score. Rotational alignment of the femur and tibial components on computed tomography was not associated with clinical outcomes.ConclusionThe tibial component internal rotational angle relative to the femoral component in the flexion position was negatively correlated with clinical outcome. Surgeons should pay attention to a rotational mismatch between components in the flexion position during the Oxford UKA procedure. Navigation systems will be effective in reducing the femorotibial rotational mismatch and improving clinical outcomes.  相似文献   

8.
BackgroundThe Physica ZUK is a fixed bearing unicompartmental knee replacement. The purpose of this prospective cohort study was to determine the mid-term clinical outcomes and survivorship of the Physica ZUK.MethodsFrom 2005 to 2017 a total of 466 Physica ZUK prostheses were implanted in 398 patients by a single surgeon. The series consisted of 452 medial and 14 lateral unicompartmental knee arthroplasties (UKAs). Three hundred and sixty-seven medial UKAs with a minimum follow-up of two years (median 5.4 years) and 14 lateral UKAs with a minimum follow-up of 18 months (median 5.3 years) were analysed using the Knee Society Knee Score (KS-KS) and Function Score (KS-FS) at latest follow-up. Kaplan Meier survivorship analysis was performed with implant revision as the end point.ResultsMean age at the time of surgery was 67 (range 42–88) and 58 (47–69) years for patients undergoing medial and lateral UKA respectively. For medial UKAs the KS-KS and KS-FS improved significantly compared to the pre-operative values from 53.6 and 54.0 to 93.4 and 91.0 respectively (p = 0.0001). For lateral UKAs the KS-KS and KS-FS improved significantly from 46.4 and 48.7 to 91.3 and 93.1 respectively (p = 0.0001). Six cases of medial UKA were revised to total knee arthroplasty. Medial implant survivorship was 97.9% (95% confidence intervals, 95.6–99.0%) at both five and 10 years. No lateral implants were revised.ConclusionThis prospective cohort study shows encouraging short to mid-term clinical results and survivorship for the Physica ZUK unicompartmental knee replacement.  相似文献   

9.
BackgroundRobotic-assisted unicompartmental knee arthroplasty (UKA) with rigid bone fixation "can significantly improve implant placement and leg alignment. The aim of this cadaveric study was to determine whether the use of robotic systems with dynamic bone tracking would provide more accurate UKA implant positioning compared to the conventional manual technique.MethodsThree-dimensional CT-based preoperative plans were created to determine the desired position and orientation for the tibial and femoral components. For each pair of cadaver knees, UKA was performed using traditional instrumentation on the left side and using a haptic robotic system on the right side. Postoperative CT scans were obtained and 3D-to-3D iterative closest point registration was performed. Implant position and orientation were compared to the preoperative plan.ResultsSurgical RMS errors for femoral component placement were within 1.9 mm and 3.7° in all directions of the planned implant position for the robotic group, while RMS errors for the manual group were within 5.4 mm and 10.2°. Average RMS errors for tibial component placement were within 1.4 mm and 5.0° in all directions for the robotic group; while, for the manual group, RMS errors were within 5.7 mm and 19.2°.ConclusionsUKA was more precise using a semiactive robotic system with dynamic bone tracking technology compared to the manual technique.  相似文献   

10.
BackgroundThere is limited published data assessing functional scores and patient satisfaction following unicompartmental knee arthroplasty (UKA) in patients with patellofemoral (PF) arthritis or anterior cruciate ligament (ACL) deficiency. The purpose of this study was to determine whether medial/central PF arthritis or functionally stable ACL deficiency compromise outcomes of fixed-bearing medial UKA at a minimum follow-up of 2 years. The hypothesis was that equivalent outcomes can be achieved in patients with substantial medial/central PF arthritis or with functionally stable ACL deficiency.MethodsThe authors studied a consecutive series of 229 patients (240 knees) at 36.9 ± 6.3 months after receiving fixed-bearing medial UKA. Patients completed pre- and post-operative (2 years) clinical outcome questionnaires for Oxford Knee Score (OKS), EQ-5D, Knee injury and Osteoarthritis Outcome Score Physical Function Short Form (KOOS-PS), University of California, Los Angeles (UCLA) activity score, and Forgotten Joint Score (FJS). Multivariable analyses were performed to determine associations between clinical scores, patient demographics, PF arthritis and functionally stable ACL deficiency.ResultsOf the 240 knees, 125 (54%) had substantial medial/central PF arthritis and 21 (9%) functionally stable ACL deficiency. Multivariable analyses revealed no association between outcomes and medial/central PF arthritis, but knees with functionally stable ACL deficiency were associated with better KOOS-PS (β = 8.99, p = 0.012).ConclusionFixed-bearing medial UKA grants satisfactory outcomes at 2 years even in knees with substantial medial/central PF arthritis or functionally stable ACL deficiency. Longer-term prospective studies with larger cohorts are needed to confirm these promising findings regarding outcomes in patients traditionally contraindicated for medial UKA.  相似文献   

11.
《The Knee》2020,27(3):1035-1042
BackgroundSevere bone and soft tissue defects are common after failed two-stage exchange arthroplasty for periprosthetic joint infection (PJI). There is a paucity of evidence on the outcomes of using a hinged prosthesis for knee PJI reconstruction during second-stage re-implantation, especially regarding implant survivorship, reinfection risk factors, and functionality after successful reconstruction.MethodsA total of 58 knee PJI patients with Anderson Orthopaedic Research Institute (AORI) type II/III defect and soft tissue insufficiency underwent reconstruction with hinged prosthesis. Enrolled patients adhered to a two-stage exchange arthroplasty protocol and were evaluated for a mean follow up of 65.1 months. Kaplan–Meier analysis was conducted for implant survivorship and infection-free survival. Multivariate analysis was used to determine independent risk factors for recurrent infections. Knee Society Score (KSS) was used to evaluate functional outcomes.ResultsThe survivorship of hinged prosthesis was 86.2% at 2 years and 70.2% at 5 years. Infection-free analysis revealed an estimation of 68.9% at 2 years and 60.6% at 5 years. Of the 58 patients, 13 (22.4%) developed recurrent PJI, three (5.2%) aseptic loosening, and one (1.7%) periprosthetic fracture. Multivariate analysis revealed that obesity (hazard ratio (HR), 3.11), high-virulent pathogen (HR, 3.44), and polymicrobial infection (HR, 3.59) were independent risk factors for reinfection. Patients showed a mean improvement of 32.8 ± 7.7 in Knee Society Clinical Score (KSCS) and 30.8 ± 11.0 in Knee Society Function Score (KSFS) after successful reconstruction (P < 0.001).ConclusionsUsing hinged knee prosthesis for PJI reconstruction provided an overall implant survival of 70.2% and an infection-free survival of 60.6% at mid-term follow up. Obesity, virulent pathogens, and polymicrobial infections were independent risk factors for infection recurrence.  相似文献   

12.
BackgroundRotating hinge implants are commonly used in revision total knee arthroplasty (TKA) in the setting of significant ligamentous instability or bone deficiency. These highly constrained implants have been associated with variable clinical outcomes and uncertain long-term survivorship. The aim of this study is to establish long-term functional outcomes, radiographic results, and survivorship after revision TKA with a rotating hinge implant.MethodThis is a retrospective study of prospectively collected data of 41 consecutive patients undergoing revision TKA with rotating hinge components and minimum 10-years follow-up. The study included 22 females (53.7%) and 19 males (46.3%) with a mean age of 66.6 ± 8.5 years. Clinical outcomes recorded included the Oxford Knee Score (OKS) preoperatively and at latest follow-up. Range of motion, implant survivorship, and complications were also recorded. Predefined radiological outcomes were obtained using plain radiographs.ResultsThere was a significant improvement in OKS after revision TKA with a rotating hinge implant compared to preoperative scores (40.7 ± 4.2 vs. 21.4 ± 4.9 respectively, p < 0.001). At latest follow-up, mean range of motion was 111.5° ± 9.3° and mean overall limb alignment was 0.2° ± 2.0° varus. Implant survivorship at minimum 10-year follow-up was 90.2%. Radiographic lucent lines were observed in 14 patients (34.1%).ConclusionRevision TKA with a rotating hinge implant leads to satisfactory clinical outcomes and very good implant survivorship at long-term follow-up. Surgeons should have a low threshold to use these versatile implants in complex revision knee arthroplasty.  相似文献   

13.
《The Knee》2020,27(3):987-992
BackgroundA biconcave polyethylene (PE) bearing was developed for mobile-bearing unicompartmental knee arthroplasties (UKA) to reduce PE dislocation.MethodsA modification of the BalanSys Unicompartmental knee system with a biconcave PE and convex tibial component was used in 32 prostheses in 28 patients. Clinical outcomes and five cases of PE fracture are reported and extensively analyzed ex vivo.ResultsVisual Analogue Score of pain and satisfaction, and Knee Society Scores improved for all patients. The passive range of motion was 130°. No PE bearings dislocated. Five bearings fractured with oxidation, cracking and delamination at the thinnest central region of the PE. The combination of increased stress and decreased poly thickness was associated with increased creep. PE oxidation caused embrittlement and contributed to fractures in the thin waist of the implant.ConclusionsThe unforeseen consequence of a novel design of a UKA that resulted in a specific mechanical and tribological mode of failure is reported. We conclude the PE failed due to a biconcave design that increased stress on the implant at its region of risk combined with a decrease of the polyethylene thickness by 1 mm in the central area.  相似文献   

14.
《The Knee》2014,21(4):843-847
BackgroundIsolated unicompartmental knee arthritis is less common laterally than medially. Lateral unicompartmental knee arthroplasty (UKA) constitutes only 1% of all knee arthroplasty performed. Use of medial UKA is supported by several published series showing good long-term survivorship and patient satisfaction, in large patient cohorts. Results of lateral UKA however have been mixed. We present the short and mid-term survivorship and 5-year clinical outcome of 101 lateral UKAs using a single prosthesis.MethodsOver a 9 year period, 100 patients who satisfied inclusion criteria underwent a lateral fixed-bearing unicompartmental arthroplasty. American Knee Society (AKSS), Oxford Knee (OKS) and modified Western Ontario McMaster Universities Arthritis Index (WOMAC) scores were completed preoperatively and at 1, 2 and 5 years postoperatively. Kaplan–Meier survival analysis was used to determine the 2-year and 5-year survivorship, using revision for any cause as end point.ResultsSurvivorship was 98.7% and 95.5% at 2 and 5 years respectively. 1 knee was revised for subsidence of the tibial component and 1 knee for progression of medial compartment osteoarthritis. Of a possible 35 knees in situ at 5 year follow-up, 33 knees were fully scored. Median AKSS, OKS and modified WOMAC scores were 182, 41, and 16 respectively.ConclusionsThe mid-term survivorship and outcome scores at 5-years suggest that lateral unicompartmental knee arthroplasty provides a valuable alternative to total joint replacement in selected patients with isolated lateral tibio-femoral arthritis at mid-term follow-up.Level II evidence.  相似文献   

15.
BackgroundLateral unicompartmental arthroplasty (UKA) constitutes only 5–10% of all unicompartmental replacements performed. Whilst the short and medium term benefits are well documented, there remains concern regarding the higher revision rate when compared with total knee replacement. We report the long term clinical outcome and survivorship of a large series of lateral UKA.Patients and MethodsBetween 1974 and 1994, 71 patients (82 knees) underwent a lateral fixed-bearing St Georg Sled UKA. Prospective data was collected pre-operatively and at regular intervals post-operatively using the Bristol Knee Score (BKS), with later introduction of the Oxford Knee (OKS) and Western Ontario MacMaster (WOMAC) scores. Kaplan Meier survival analysis was used, with revision, or need for revision, as end point. 85% of the patients were female. No patients were lost to follow-up.ResultsFunctional knee scores improved post-operatively up to 10 years, at which point they demonstrated a steady decline. Survivorship was 72% at 15 years, and 68% at 20 and 25 years. Nineteen knees were revised, with progression of disease in another compartment the commonest reason. There were two revisions due to implant fracture. In patients aged over 70 years at time of index procedure, 81% died with a functioning prosthesis in situ.ConclusionThis represents the longest follow-up of a large series of lateral UKA. Results of this early design of fixed bearing UKA demonstrate satisfactory long term survivorship. In elderly patients, further intervention is rarely required. More contemporary designs or techniques may show improved long term survivorship in time.  相似文献   

16.
《The Knee》2020,27(5):1325-1331
BackgroundParkinson's disease (PD) adversely affects physical function after joint replacement. The biomechanical advantages of unicompartmental knee arthroplasty (UKA) may be particularly beneficial for these patients who suffer from gait and kinetic abnormalities. We aimed to describe the functional outcomes, complications and survivorship after UKA in patients with PD.MethodsTen patients (11 knees) undergoing primary fixed-bearing UKA for medial osteoarthritis were studied. Knee Society Knee (KSKS) and Function Scores (KSFS), as well as the Short-Form-36 (SF-36) Mental (MCS) and Physical Component Scores (PCS) were assessed preoperatively, at six months and at two years postoperatively. Complications, survivorship and all-cause mortality were analyzed.ResultsNo perioperative complications occurred. Length of stay was 5 ± 2 days and no patients were discharged to rehabilitation or readmitted. Nine of 11 knees had a flexion contracture preoperatively and this remained unchanged at two years. KSKS and SF-36 PCS improved significantly. However, there was no improvement in KSFS or SF-36 MCS. All patients achieved minimal clinically important difference for KSKS, six of 11 for KSFS and nine of 11 for SF-36 PCS. At mean 10 ± 5 years, there was one revision for progression of osteoarthritis. Seven of 10 patients progressed in Hoehn and Yahr stage and only three were able to ambulate independently at last follow-up.ConclusionsPatients suffering from osteoarthritis and PD can experience a substantial improvement in knee pain with low morbidity after UKA. However, the improved kinematics of UKA did not translate to an improved range of motion or knee function postoperatively.  相似文献   

17.
《The Knee》2020,27(3):1018-1027
BackgroundUnicompartmental knee arthroplasty (UKA) accounts for 8.9% of knee arthroplasty procedures in England, Wales and Northern Ireland. Fixed bearing UKA designs have shown favourable survivorship in registries when compared with mobile bearings but some studies suggest poor survival of all-polyethylene fixed tibial bearings. This study analyses long-term follow-up of patients with a medial fixed all-polyethylene tibial bearing UKA and reports survivorship and 10-year clinical outcomes.MethodsData was collected prospectively for 214 medial unicompartmental all-polyethylene tibial bearing UKAs implanted in 184 patients at our tertiary referral centre between November 2002 and December 2007. The indication was osteoarthritis in all but one patient. Patient reported outcome scores were documented pre-operatively and at five, eight, 10 and 12 years of follow-up. The mean patient age was 70 years (range 41–87).ResultsOutcome and survivorship data were collected for 214 medial all-polyethylene tibial bearing UKAs. There were outcomes recorded for 83 UKAs with at least 10-year follow-up. Twenty-four patients underwent revision of their UKA at an average of 5.84 years after the primary procedure. Kaplan–Meier analysis demonstrated survivorship of 89.1% at 10 years and the OKS, AKSS and WOMAC patient reported outcomes remained significantly improved in comparison to preoperatively. For those 70 years or older, 10-year survivorship was 92.4%, compared to 85.0% for those under 70 years old.ConclusionMedial fixed all-polyethylene tibial bearing UKA demonstrates acceptable long-term survivorship and patient outcomes. It appears to be a suitable option for the treatment of medial compartment OA, particularly in older patients.  相似文献   

18.
《The Knee》2020,27(5):1492-1500
BackgroundPatellofemoral joint (PFJ) degeneration has been found not to affect outcome following medial unicompartmental knee arthroplasty (UKA). However, PFJ disease occasionally presents as isolated trochlear cartilage lesions, with little available evidence regarding treatment options or necessity. We evaluated the effectiveness of concomitant trochlear resurfacing in patients undergoing medial UKA with asymptomatic trochlear lesions.MethodsWe included 60 patients undergoing medial UKA with an associated full thickness lesion of the trochlea. A fixed bearing UKA implant (PKR™, Stryker, Warsaw, IND) was used in all cases. In 30 patients, trochlear lesions were resurfaced with a HemiCAP® PF Classic (HemiCAP® PFC) implant (Arthrosurface, Franklin, MA). Outcome measures included VAS-, KOOS-, WOMAC-, SF-36 scores and radiological assessment.ResultsAverage length of follow-up was 97.4 months (range: 88–106 months). Both groups showed significant improvement for all clinical scores post-operatively compared to pre-operatively (p < 0.001 for all). The UKA group showed a better VAS score at all follow-up moments (p < 0.01 for all), but no differences were found between both groups at all time points for other outcome measures. None of the HemiCAP® PFC implants needed to be revised within the timeframe of the study.ConclusionsIn this retrospective cohort study, we found a 100% survivorship of the HemiCAP® PFC implant at an average eight-year follow-up. However, no clinical benefits were found in performing trochlear resurfacing in conjunction with medial UKA for asymptomatic end-stage trochlear cartilage lesions. Therefore, these lesions can be safely ignored when performing a medial UKA.  相似文献   

19.
AimsRevision knee replacement is an increasingly common procedure, however, information on patient-focused outcomes is limited. This systematic review and meta-analysis aimed to investigate the medium-term patient reported outcomes following a revision knee replacement.MethodsWe performed a systematic review of MEDLINE and EMBASE (from inception to 1st March 2021) for articles reporting five year or greater patient reported outcome measures (PROMs) following revision knee replacement. A meta-analysis of PROMs data was undertaken using the Standardised Mean Difference (SMD). Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROPSERO (CRD42021199289).ResultsA total of 23 studies met the inclusion criteria containing 2414 patients at a mean minimum follow-up of 74 months (60–122). The reporting of PROMs were poorly standardised with several PROMs being used. The most commonly reported patient reported outcome was the Knee Society Score reported in 65% of studies (15/23). A meta-analysis of 629 eligible patients undergoing revision knee replacement revealed a significant improvement in pre-operative state with a SMD 2·05 95% CI 0.87, 3.23.ConclusionThis systematic review has found a significant and sustained improvement in patient-reported outcomes following a revision knee arthroplasty beyond five years. We found a variation in the usage and administration of PROMs which hinders a clear synthesis of results. Furthermore, the PROMs have not been robustly tested for validity in the context of a revision knee replacement.  相似文献   

20.
《The Knee》2020,27(3):1003-1009
BackgroundIn patellofemoral replacement (PFR) coronal alignment is mostly influenced by local condylar anatomy. However, there is still a lack of consensus regarding references to follow intraoperatively for the optimal positioning of the trochlear component. The aim of this study was to assess whether aiming for the anatomical femoral axis on the coronal plane leads to improved clinical outcomes and whether coronal alignment correlates with clinical outcomes.MethodsForty-two patients who underwent PFR were retrospectively evaluated at a minimum one-year follow-up using Kujala and Knee Society Score (KSS). Moreover, patients underwent an anteroposterior hip-to-knee X-ray to evaluate the coronal alignment of the trochlear component with respect to the femoral anatomic and mechanical axis. Prosthesis coronal alignment, Kujala, and KSS were assessed for possible correlation.ResultsMean follow-up time: 29.1 months. Mean KSS for pain: 90 (± 8.9), for function: 93.7 (± 15.9); mean Kujala: 89.2 (± 13.6). Mean prosthesis coronal alignment was 3.3 ± 2.3° in valgus with respect to the femoral anatomic axis and 7.4 ± 2.6° in valgus with respect to the femoral mechanical axis. No correlations were found between coronal alignment and KSS or Kujala scores.ConclusionsResults from the current study showed that PF replacement with a third-generation implant led to good-to-excellent outcomes. In addition, the surgical technique used for aligning femoral component in this study resulted in reduced coronal alignment variability and achieved good short-term clinical outcomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号