共查询到20条相似文献,搜索用时 15 毫秒
1.
Simonetti G Gandini R Versaci F Pampana E Fabiano S Stefanini M Spinelli A Reale CA Di Primio M Gaspari E 《European radiology》2009,19(4):982-989
Carotid artery stenting (CAS) may be an alternative to surgical endoarterectomy not only in high-risk patients. We report results in the endovascular treatment of carotid artery disease with up to 8 years' follow-up. In this retrospective study, we analysed data from 853 consecutive patients (946 arteries) treated for carotid artery stenosis between April 1999 and March 2007; 491 (52%) arteries were symptomatic and 455(48%) were asymptomatic. Preprocedural evaluation of the patients was performed with echo Doppler, magnetic resonance angiography (MRA) or computed tomographic angiography (CTA) and a neurological examination. A cerebral protection device was used in 879 (92.9%) procedures. Anti-platelet therapy was administered before and after the procedure. All patients were included in a follow-up of up to 8 years. Technical success was achieved in 943 (99.6%) lesions. At 30 days, there was a 0.21% (n = 2) death rate, a 0.42% major stroke rate, a 1.69% minor stroke/transient ischaemic attack (TIA) rate and a combined 2.32% TIA/stroke and death rate. During follow-up, echo Doppler evidenced restenosis in 39 (4.85%) cases; of these, only five, presenting restenosis >80%, were treated with an endovascular reintervention. At the long-term follow-up, two strokes (0.23%) were reported, which both occurred within the first 2 years. In our experience, carotid artery stenting seems to be a safe and effective treatment, providing satisfactory long-term clinical results. 相似文献
2.
C. M. Kowoll W. Moeller-Hartmann G. R. Fink W. F. Haupt J. Sobesky 《Neuroradiology》2013,55(9):1135-1141
Introduction
In acute symptomatic vertebrobasilar artery stenosis, the use of mechanical recanalisation remains controversial. The complication rate of acute interventional recanalisation (aIR) has to be considered, as evidence from randomised trials is lacking. In a single centre retrospective case series, we here describe complications and outcome after aIR.Methods
We retrospectively assessed aIR in a tertiary care centre and included the following parameters: indication for aIR, national institute of health stroke scale (NIHSS) score on admission, recanalisation by thrombolysis in myocardial infarction score (TIMI) grades, post-interventional complications, mortality, NIHSS and modified Rankin scale at follow-up and rate of restenosis.Results
We identified 14 aIR (14 percutaneous transluminal angioplasty with or without stent implantation in 12 patients; 6/12 with thrombolysis; n?=?6 vertebral artery, n?=?8 basilar artery; 4 women, mean age 67 years). Mortality was 25 % (3/12) after 7 days and 42 % (5/12) after 12 months. In 12/14, interventions are complete (TIMI 3, 86 %), in 2/14, a partial recanalisation (TIMI 2, 14 %) was achieved. In one case, a peri-interventional fatal intracerebral haemorrhage occurred (1/12, 8 %). At late follow-up (mean 342 days), one re-occlusion (1/7, 14 %) and one recurrent stroke (1/12, 8 %) were observed.Conclusions
In our single centre series of vertebrobasilar aIR recanalisation rate was high. However, procedural safety and clinical outcome varied considerably. The results of aIR need to be assessed in multicentric registers to define the procedural risk and outcome in the clinical setting. 相似文献3.
Antti Paakkala Petri Sillanpää Heini Huhtala Timo Paakkala Heikki Mäenpää 《Skeletal radiology》2010,39(7):675-682
Objective
The aim of the study was to assess volumetric analysis of bone bruises in acute primary traumatic patellar dislocation by magnetic resonance imaging (MRI) and resolving resolution of bruises in follow-up MRI. 相似文献4.
Bertrand Sonnery-Cottet F. Lavoie R. Ogassawara R. G. Scussiato J. F. Kidder P. Chambat 《Knee surgery, sports traumatology, arthroscopy》2010,18(1):47-51
The purpose of this study was to describe an original technique of reconstruction of the anteromedial bundle preserving the posterolateral bundle and to report the results of a consecutive 36 patients series with mean 24 months follow-up. Our hypothesis is that this selective reconstruction of ACL partial tears could restore knee stability and function. In a consecutive series of 256, ACL reconstructions, 36 patients in which intact ACL fibers remained in the location corresponding to the posterolateral bundle were perioperatively diagnosed. These patients (21 women and 15 men) underwent isolated reconstruction of the anteromedial bundle while keeping the remaining fibers intact. AM bundle reconstructions were performed by the same surgeon using an outside-in technique. A quadrupled hamstring graft was used in 20 patients and a doubled semitendinosus graft in 16 patients. The mean age of the patients at the time of surgery was 32 years (min 15, max 53). The delay between injury and surgery was 6.6 months (min 2, max 35). Patients were assessed with the IKDC ligament evaluation form. Instrumented knee testing was performed with the Rolimeter arthrometer. Statistical analysis was performed to compare the preoperative and postoperative objective evaluation. Eleven concomitant meniscal lesions at the time of reconstruction were found. One patient who underwent a traumatic graft rupture at 4 months post surgery and two patients with previous contralateral ACL reconstruction were excluded, leaving 33 patients for final evaluation. Three reoperations were performed, including two arthrolysis for cyclops syndrome and one revision for a traumatic graft rupture. At last follow-up, 24 (73%) patients were graded A, 8 (24%) graded B and 1 C (3%) at IKDC objective evaluation. Mean side to side instrumented laxity was 4.8 mm (min 3, max 6) preoperatively and 0.8 mm (min 0, max 2) postoperatively. AM bundle reconstruction with an outside-in technique remains simple and reproducible. The preliminary results are encouraging with excellent side to side laxity. Graft size should probably be adapted to limit cyclops syndrome occurrence. 相似文献
5.
Rigatelli G 《AJNR. American journal of neuroradiology》2006,27(1):11; author reply 11-11; author reply 12
6.
Simonetti G Gandini R Versaci F Pampana E Fabiano S Stefanini M Spinelli A Reale CA Di Primio M Gaspari E 《La Radiologia medica》2009,114(1):95-110
Purpose
Carotid artery stenting (CAS) may be an alternative to surgical endarterectomy not only in high-risk patients. Few data are available regarding the long-term clinical efficacy of CAS with the use of cerebral protection devices and the incidence of restenosis. Our experience demonstrates that if certain requirements are fulfilled, CAS can be considered a safe and effective treatment with high short-and long-term success rates.Materials and methods
In the past 8 years, we treated 1,003 patients (1,096 arteries) affected by internal carotid artery stenosis, 93 with bilateral stenosis. Of these, 567 (51.74%) were symptomatic and 529 (48.26%) asymptomatic lesions. The preprocedural evaluation was performed with Doppler ultrasound (US), magnetic resonance (MR) angiography/computed tomography (CT) angiography and a neurological evaluation. Antiplatelet therapy was administered before and after the procedure.Results
Technical success was achieved in 1,092 cases (99.6%), and a cerebral protection device was successfully used in 1,019 procedures (92.9%). The 30-day transient ischaemic attack (TIA)/stroke/death rate was 2.16%: death (0.18%) major stroke (0.45%) and minor stroke/TIA (1.53%). During a follow-up up to 8 years, restenoses occurred in 39 cases (3.57%), of which 28 were post-CAS (2.57%) and 11 post-CAS performed for restenosis after carotid endarterectomy (1%). Only five symptomatic restenoses >80% were treated with a repeated endovascular procedure.Conclusions
A retrospective analysis of our experience suggests that CAS is a safe and effective procedure with better results than endarterectomy. In up to 8 years of follow-up, CAS seems to be effective in preventing stroke, with a low restenosis rate. 相似文献7.
In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4–5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN . Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2–4%. Consequent stent surveillance with regular stent exchange is mandatory. 相似文献
8.
Percutaneous transluminal angioplasty of proximal vertebral artery stenosis: long-term clinical follow-up of 16 consecutive patients 总被引:2,自引:0,他引:2
Janssens E Leclerc X Gautier C Godefroy O Koussa M Hénon H Lucas C Leys D Pruvo JP 《Neuroradiology》2004,46(1):81-84
We report long-term (average 30 months) clinical and radiological follow-up of 16 consecutive patients with uni- or bilateral proximal vertebral artery stenosis who underwent percutaneous transluminal angioplasty (PTA), without stenting, between 1995 and 1998. Assessment was performed by an independent neurologist. All patients but one remained asymptomatic during follow-up; moderate restenosis was observed in four. PTA of the proximal vertebral artery is safe but in the absence of knowledge of the natural history of atherosclerotic vertebral artery stenosis, whether it is beneficial or not remains unproven. The decision as to whether to perform this procedure is individual. 相似文献
9.
Gillard JH 《Neuroradiology》2003,45(10):671-680
There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function.An addendum to this article can be found at 相似文献
10.
《Clinical imaging》2014,38(5):681-685
ObjectivesThe prevalence of the “bovine” arch in the population is known (8–25%). However, its prevalence in patients with significant carotid atherosclerosis has never been investigated. Altered flow patterns or turbulence that may occur in these patients may play a causative role in the development of atherosclerotic lesions. The primary purpose of this study was to retrospectively compare the prevalence of aortic arch variants in patients with and without significant carotid artery atherosclerosis, as we hypothesize that carotid atherosclerosis may be more prevalent in patients with a bovine arch due to hemodynamic alterations. A secondary objective was to review radiologist reporting of arch anatomy.MethodsSingle-center, retrospective, case-control study in which 79 patients with hemodynamically significant carotid artery atherosclerosis who underwent computed tomography angiography, magnetic resonance angiography, or unenhanced computed tomography (CT) imaging including the aortic arch were identified. These patients were then compared with 95 randomly selected controls without carotid atherosclerosis that underwent similar imaging during the same time period. Images were independently reviewed by two blinded radiologists, who assessed arch anatomy as normal, bovine, or other variant. The original radiology reports were reviewed for reporting of arch anatomy.ResultsIn controls, 70% had normal arch anatomy, and 24% had a bovine arch. Among patients with significant carotid disease, these numbers were 70% and 20%, respectively. There was no statistically significant difference between incidence of arch variants in subjects with and without carotid artery atherosclerosis (P=.97). There was good interreader agreement. Among patients with aortic arch anomalies, 20% of the original radiology reports did not mention arch anatomy.ConclusionsIn our experience, percentage of bovine arch anomalies in patients with significant carotid atherosclerosis is not significantly different from those without disease. Clinicians should be aware of the high prevalence of arch anomalies, which can impact endovascular approach and management, and radiologists should be aware of the clinical importance of reporting such variants. 相似文献
11.
There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function.The online version of the original article can be found at 相似文献
12.
Daying Dai Yong Hong Ding Ramanathan Kadirvel Arash Ehteshami Rad Debra A. Lewis David F. Kallmes 《Neuroradiology》2013,55(1):65-70
Introduction
Previous studies have noted formation of saccular aneurysms along the distal basilar artery/P1 segments after carotid ligation in rabbits. In this prospective study we employed MICROFIL®, a polymer, which was used to fill the entire arterial tree, to examine the incidence of microaneurysm formation following right common carotid artery (RCCA) ligation in rabbits.Methods
RCCA ligation was performed in 18 New Zealand White rabbits for 0 day (n?=?2), 3 weeks (n?=?6), or 16 weeks (n?=?10). Three control rabbits without carotid surgery were sacrificed at 4 weeks. At the time of sacrifice, MICROFIL® MV-122 yellow was injected through left CCA to fill cerebral vasculature. After gross photographs were taken, specimens were embedded, sectioned, and stained for histopathological evaluation. Tissue and sections were carefully evaluated for microaneurysm formation, defined as a localized dilatation of the vessel wall, associated with fragmentation or complete loss of the internal elastic lamina (IEL), and/or medial degeneration.Results
Gross examination with MICROFIL® opacification demonstrated no evidence of saccular aneurysm formation, but prominent perforating vessels were present in all 19 cases at, or adjacent to, the basilar terminus. Branches noted upon gross examination corresponded histologically to small, saccular contour defects, which demonstrated apparent loss of the IEL and apparent medial thinning. These observations, however, were a consequence of sectioning through the bases of perforating arteries, which simulated microaneurysm formation.Conclusions
Unilateral carotid ligation does not induce microaneurysm formation at the basilar terminus in rabbits. Prominent perforating arteries as well as tissue injury from the processing may simulate “aneurysms” histologically. 相似文献13.
14.
Introduction
Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent.Methods
ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated.Results
With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant.Conclusion
ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction. 相似文献15.
Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive imaging alternative to digital subtraction angiography
(DSA) for patients with carotid artery disease. In DSA, image quality can be improved by shifting the mask image if the patient
has moved during angiography. This study investigated whether such image registration may also help to improve the image quality
of carotid MRA. Data from 370 carotid MRA examinations of patients likely to have carotid artery disease were prospectively
collected. The standard nonregistered MRAs were compared to automatically linear, affine and warp registered MRA by using
three image quality parameters: the vessel detection probability (VDP) in maximum intensity projection (MIP) images, contrast-to-noise
ratio (CNR) in MIP images, and contrast-to-noise ratio in three-dimensional image volumes. A body shift of less than 1 mm
occurred in 96.2% of cases. Analysis of variance revealed no significant influence of image registration and body shift on
image quality (p > 0.05). In conclusion, standard contrast-enhanced carotid MRA usually requires no image registration to improve image quality
and is generally robust against any naturally occurring body shift.
Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users. 相似文献
16.
Outside-in meniscus suture technique: 5 years' follow-up 总被引:1,自引:0,他引:1
We present the results of a prospective study evaluating the arthroscopic technique of outside-in meniscus suture (n=68). The types of tears suitable for suture consisted of acute vertical tears, solitary or in association with a radial tear in middle third. The technique was always outside-in using resorbable sutures (2-0 PDS, 2-0 Maxon). Follow-up evaluation included clinical examination, radiographic examinations and second-look arthroscopies (n=10). There were four failures in this study, consisting of rerupture of the meniscus. Clinical results were good in 91% with complete recovery and return to physical and sportive activity, good in 3% with mild symptoms, and failure in 6% consisting of meniscus rerupture. 相似文献
17.
Naka T Sasaki Y Kawaguchi S Fujita M Takeda M Umezawa S Tomiyama T 《Nihon Hoshasen Gijutsu Gakkai zasshi》2012,68(1):85-94
Recently, T? weighted image (T?WI) has proven to be useful for diagnosing carotid plaque. This time, the image parameter of two-dimensional spin echo (2D SE) T?WI was examined. Phantoms that imitated muscle and carotid plaque were made. Signal noise ratio (SNR) and the contrast of phantoms were examined when the flip angle (FA) of radio frequency (RF) pulse, repetition time (TR), and echo train length (ETL) was changed. A visual evaluation was done in a clinical case. Both SE and fast spin echo (FSE) SNR improved according to the extension of TR, and the contrast decreased. Moreover, the contrast improved when there was a lot of ETL and the FA of RF pulse. It is thought that this is because SNR and the contrast depend on the interrelation of TR, T? value, and the FA of RF pulse. When the FA of RF pulse was set to 70 degrees and the TR was set to 400 ms resulting from the phantom experiment, clinical cases obtained great results. This examination confirmed the utility of 2D SE in carotid plaque inspection. 相似文献
18.
Bayram B Uckan S Acikgoz A Müderrisoglu H Aydinalp A 《Dento maxillo facial radiology》2006,35(4):266-270
OBJECTIVES: The aim of the present study is to evaluate the panoramic radiographs of 4106 patients for carotid artery atheromas (CAAs) and to correlate our findings with the literature. MATERIALS AND METHODS: The digital panoramic radiographs of 4106 dental patients (2428 female, 1678 male) were evaluated. Radiographs of patients 40 years of age or older were randomly chosen from a computer database. CAA findings were defined as radiopaque masses adjacent to the cervical vertebrae at or below the intervertebral space between C3 and C4 on the panoramic radiograph. The patients who had CAA findings were contacted by telephone, and some of them agreed to further evaluation. Evaluation included carotid ultrasound, ECG, echocardiography and treadmill exercise testing at the Department of Cardiology. RESULTS: Of 4106 patients, 88 patients (2.1%; 70 female, 18 male) had one or more radiopaque mass detected on digital images. All 88 patients with CAA findings were contacted by telephone and 23 agreed to further evaluation at the university hospital. Of these 23 patients, 8 (34.7%) had CAAs on carotid ultrasound and 15 (65.3%) had normal carotid arteries. From these eight patients with CAAs on Doppler ultrasound, 7 (30.4%) had plaques that were not haemodynamically significant and only one (4.3%) had significant plaque. The patient with severe carotid artery stenosis consequently underwent endarterectomy operation. There were no statistically significant differences between male and female in CAAs (P>0.05). CONCLUSION: Digital panoramic images may have some diagnostic value for detecting CAAs and this early diagnosis could potentially increase the length and quality of life for people with CAAs. 相似文献
19.
20.
Marcelo Borghi Ezequiel Becher Marcelo Bou Luis Montes de Oca Juan Fernandez Long Luisa Rafailovici Luisa Filomia Edgardo F. Becher 《Brachytherapy》2019,18(4):462-469
PurposeImplanted rectal spacers (IRS) have been developed to increase the distance between the prostate and the rectum, thus optimizing dose escalation. Cost is a disadvantage and there are still uncertainties as to their durability. We have developed an autologous fat transfer (AFT) technique to use as an IRS. We aim to present the feasibility and durability at 6 months of AFT placed immediately after the implant of the seeds in low-dose-rate brachytherapy (BT).Methods and MaterialsThirty-five patients underwent AFT (12 were treated with primary BT, 7 with a combined primary treatment of external beam radiotherapy + BT, 16 with salvage BT). The isodose used for primary BT was 14400 cGy, 11,000 cGy after 4600 cGy of external beam radiotherapy in the combined group, and 14400 cGy for the salvage group. Patients underwent a CT scan at 1, 3, and 6 months to measure the distance between the rectum and the prostate.ResultsAn average of 32.7 cc (20–40) of fat was transferred successfully in 100% of cases. The mean distance to the rectum at the level of the base, middle, and apex at 1 and 6 months were 11.2, 9.7, and 7.6 mm; 8.3, 8.1, and 5.9 mm, respectively. No rectal toxicity or major complications were reported.ConclusionsThe use of fat as an IRS seems to be a valid alternative to reduce rectal toxicity after BT, achieving equivalent distances to synthetic IRS. It is feasible, safe, and the loss of distance at 6 months is small. Cost is lower than other alternatives. 相似文献