首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of sumatriptan in tablet dosage forms. The stationary phase used was precoated silica gel 60F254. The mobile phase used was a mixture of methanol:water:glacial acetic acid (4.0:8.0:0.1, v/v/v). The detection of spots was carried out at 230 nm. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot. The limit of detection and the limit of quantification for the sumatriptan were found to be 63.87 and 193.54 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.  相似文献   

2.
A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the simultaneous estimation of valsartan and hydrochlorothiazide in combined dosage forms. The stationary phase used was precoated silica gel 60F254. The mobile phase used was a mixture of chloroform: methanol: toluene: glacial acetic acid (6:2:1:0.1 v/v/v/v). The detection of spots were carried out at 260 nm. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 300 to 800 ng/spot for valsartan and 100 to 600 ng/spot for hydrochlorothiazide. The limit of detection and the limit of quantification for the valsartan were found to be 100 and 300 ng/spot respectively and for hydrochlorothiazide 30 and 100 ng/spot respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.  相似文献   

3.
The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.  相似文献   

4.
In the present work new, simple reversed-phase high performance liquid chromatographic method was developed and validated for the determination of hydroxychloroquine sulphate in blood plasma. Chloroquine sulphate was used as an internal standard. The chromatographic separation was achieved with octadecyl silane Hypersil C18 column (250×6 mm, 5 μm) using water and organic (acetonitrile:methanol: 50:50, v/v) mobile phase in 75:25 v/v ratio, with sodium 1-pentanesulfonate and phosphoric acid. This organic phase was maintained at pH 3.0 by orthophosphoric acid. The flow rate of 2.0 ml/min. with detection at 343 nm was used in the analysis. The calibration curve of standard hydroxychloroquine sulphate was linear in range 0.1-20.0 μg/ml. The method was validated with respected to linearity, range, precision, accuracy, specificity and robustness studies according to ICH guidelines. The method was found to be accurate and robust to analyze the hydroxychloroquine sulphate in plasma samples.  相似文献   

5.
Fluocortolone and its esters are synthetic corticosteroids used topically in the treatment of various skin disorders. A method that can be successfully used for the separation and determination of fluocortolone pivalate and fluocortolone hexanoate in suppositories was developed. This method is based on reverse-phase HPLC on Supelcosil LC-18 (25 cm x 4.6 mm, 5 microns), using methanol-acetonitrile-water-glacial acetic acid (17:46:37:0.4 v/v/v/v) as mobile phase at a flow rate of 3.0 ml/min. Detection was carried out using a UV detector at 238 nm. The method developed was validated, and calibration curves were established dependent on peak area. The validated ranges for fluocortolone pivalate and fluocortolone hexanoate are 15-305 micrograms/ml (r = 0.9995) and 15-315 micrograms/ml (r = 0.9996), respectively. The limits of detection and the limits of quantification for both esters were also determined.  相似文献   

6.
A simple, specific, accurate, and precise reverse phase liquid chromatographic method was developed and validated for the estimation of risperidone in tablet dosage forms. A Phenomenex Gemini C-18, 5 μm column having 250×4.6 mm i.d. in isocratic mode, with mobile phase containing methanol: acetonitrile: 50 mM potassium dihydrogen orthophosphate (80:10:10 v/v) was used. The flow rate was 1.3 ml/min and effluents were monitored at 234 nm. Clozapine was used as an internal standard. The retention time of risperidone and clozapine were 2.5 min and 3.3 min, respectively. The method was validated for linearity, accuracy, precision, specificity, limit of quantification, limit of detection, robustness and stability. The limit of detection and limit of quantification for estimation of risperidone was found to be 500 ng/ml and 990 ng/ml, respectively. Recovery of risperidone was found to be in the range of 99.02-101.68%. Proposed method was successfully applied for the quantitative determination of risperidone in tablet formulations.  相似文献   

7.
A chiral high performance liquid chromatographic method was developed and validated for the enantiomeric resolution of Valacyclovir, L-valine 2-[(2-amino-1,6-dihydro-6-oxo-9h-purin-9-yl) methoxy] ethyl ester, an antiviral agent in bulk drug substance. The enantiomers of Valacyclovir were resolved on a Chiralpak AD (250 mm x 4.6 mm, 10 microm) column using a mobile phase system containing n-hexane: ethanol: diethylamine (30:70:0.1, v/v/v). The resolution between the enantiomers was found not less than four. The presence of diethylamine in the mobile phase has played an important role in enhancing chromatographic efficiency and resolution between the enantiomers. The developed method was extensively validated and proved to be robust. The limit of detection and limit of quantification of (D)-enantiomer were found to be 300 and 900 ng/ml, respectively, for 20 microL injection volume. The calibration curve showed excellent linearity over the concentration range of 900 ng/ml (LOQ) to 6000 ng/ml for (D)-enantiomer. The percentage recovery of (D)-enantiomer was ranged from 97.50 to 102.18 in bulk drug samples of Valacyclovir. Valacyclovir sample solution and mobile phase were found to be stable for at least 48 h. The proposed method was found to be suitable and accurate for the quantitative determination of (D)-enantiomer in bulk drugs substance. It can be also used to test the stability samples of Valacyclovir.  相似文献   

8.
A rapid, sensitive and specific reversed-phase high performance liquid chromatographic method with diode-array detection has been developed and validated for the determination of hydroxybenzene (0.494%, w/w) in a commercially available cream pharmaceutical formulation. Isocratic chromatography was performed on a C18 column with methanol-water 60:40 (v/v) containing 0.1% phosphoric acid (v/v) as mobile phase at a flow rate of 1.0 ml/min. UV detection was at 254 nm. Linearity of the method was excellent (r(2) = 0.9999). The relative standard deviation values for intra- and inter-day precision studies were < 1% and the recovery of hydroxybenzene was >99%. The limit of detection and quantitation for hydroxybenzene was found to be 13.5 η g/ml and 2 μg/ml, respectively. The method was also validated for specificity and robustness. The method was found to be robust and can be reliably used to determine the hydroxybenzene content of marketed formulations.  相似文献   

9.
The present paper describes the development of a stability indicating reversed phase liquid chromatographic (RPLC) method for oxcarbazepine in the presence of its impurities and degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation of oxcarbazepine was observed under base hydrolysis. The drug was found to be stable to other stress conditions attempted. Successful separation of the drug from the synthetic impurities and degradation product formed under stress conditions was achieved on a C18 column using mixture of aqueous 0.02 M potassium dihydrogen phosphate–acetonitrile–methanol (45:35:20, v/v/v) as mobile phase. The developed HPLC method was validated with respect to linearity, accuracy, precision, specificity and robustness. The developed HPLC method to determine the related substances and assay determination of oxcarbazepine can be used to evaluate the quality of regular production samples. It can be also used to test the stability samples of oxcarbazepine.  相似文献   

10.
The objective of current investigation was to study the degradation behaviour of eberconazole nitrate and mometasone furoate under different International Conference on harmonisation recommended stress condition using reverse phase high performance liquid chromatographic method and to establish validated stability-indicating high performance liquid chromatographic method to determine purity of eberconazole nitrate and mometasone furoate in presence of its impurities, forced degradation products and placebo in pharmaceutical dosage forms. The method was developed using Hypersil BDS, C18, 150Χ4.6 mm, 5 μ as stationary phase with mobile phase containing a gradient mixture of solvent A and B. 0.01 M phosphate buffer with 0.1% triethyl amine, adjusted pH 7.0 with phosphoric acid was used as buffer. Buffer pH 7.0 was used as solvent A and methanol:acetonitrile in 150:850 v/v ratios were used as solvent B. The eluted compounds were monitored at 240 nm. The run time was 50 min. The developed method was validated as per international conference on harmonization guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness.  相似文献   

11.
Simple, specific, accurate and precise method, namely, reverse phase high performance liquid chromatography was developed for estimation of duloxetine HCl in pharmaceutical formulations. For the high performance liquid chromatography method, Phenomenox C-18, 5 μm column consisting of 250×4.6 mm i.d. in isocratic mode, with mobile phase containing 0.01M 5.5 pH phosphate buffer: acetonitrile (60:40 v/v) and final pH adjust to 5.5±0.02 with phosphoric acid was used. The flow rate was 1.2 ml/min and effluent was monitored at 231 nm. The retention time was 5.61 min. The method was validated in terms of linearity, accuracy and precision. The linearity curve was found to be linear over 0.25-4 μg/ml. The limit of detection and limit of quantification were found to be 0.10 and 0.25 μg/ml respectively. The proposed method was successfully used to determine the drug content of marketed formulations.  相似文献   

12.
In the pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipment and areas. The cleaning procedures must be validated and the methods to determine trace amounts of drugs have therefore to be considered with special attention. A high performance liquid chromatographic method for the determination of amlodipine residues in swab samples was developed and validated in order to control a cleaning procedure. The swabbing procedure was optimized in order to obtain a suitable recovery of amlodipine from stainless steel. A mean recovery close to 90% was obtained when two swabs moistened with methanol were used. The residual amlodipine was chromatographed at 25 degrees C in the isocratic mode on a RP-18 stationary phase using a mobile phase consisting of acetonitrile, methanol and pH 3.0 triethylamine solution (15:35:50 v/v/v). UV detection was performed at 237 nm. The method was shown to be selective and linear into the concentration range varying from 0.39 to 1.56 microg/ml. Accuracy and precision of the method were also studied. The limits of detection and quantitation were evaluated to be 0.02 and 0.08 microg/ml, respectively. The stability of amlodipine at different steps of the sampling procedure and the precision of the swabbing procedure were also investigated.  相似文献   

13.
A reverse phase high performance liquid chromatography method was developed for simultaneous estimation of nitazoxanide and ofloxacin in tablet formulation. The separation and quantification was achieved by Hiq Sil C18V Size 4.6 mm Ø *250 mm column in isocratic mode, with mobile phase consisting of acetonitrile-methanol-0.4 M citric acid, (60:30:10, v/v/v). Citric acid used to stabilize nitazoxanide and ofloxacin in mobile phase. The mobile phase was pumped at a rate of 0.6 ml/min and the detection was carried out at 304 nm. The retention time of ofloxacin and nitazoxanide was found to be 3.122 and 5.902 min, respectively. The method was validated for linearity, accuracy, and precision. Linearity for ofloxacin and nitazoxanide were in the range 2-36 μg/ml and 5-90 μg/ml, respectively. The developed method was found to be accurate, precise and selective for simultaneous estimation of ofloxacin and nitazoxanide in tablets.  相似文献   

14.
A rapid and sensitive reverse phase high performance liquid chromatographic method is depicted for the qualitative and quantitative assay of letrozole in pharmaceutical dosage forms. Letrozole was chromatographed on a reverse phase C18 column with a mobile phase consisting of acetonitrile and phosphate buffer (pH 7.8) in the ratio of 70:30 v/v. The mobile phase was pumped at a flow rate of 1 ml/min. Acenaphthene was used as an internal standard and the eluents were monitored at 232 nm. The retention time of the drug was 3.385 min. With this method, linearity was observed in the range of 10-100 μg/ml. The LOD and LOQ were found to be 0.51 μg/ml and 1.52 μg/ml, respectively. The method was found to be applicable for analysis of drug in tablets. The results of the analysis were validated statistically.  相似文献   

15.
A simple, selective, rapid, precise and economical reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of nebivolol and hydrochlorthiazide from pharmaceutical formulation. Phenomenex Gemini C(18) (25 cm×4.6 mm i.d., 5 μ) column with a mobile phase consisting of acetonitrile: 50mM ammonium acetate (adjusted to pH 3.5 using orthophosphoric acid) (70:30 v/v) at a flow rate of 1.0 ml/min was used. Detection was carried out at 254 nm. Probenecid was used as an internal standard. The retention times of probenecid, nebivolol and hydrochlorthiazide were 13.05, 3.32 and 4.25 min, respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for the estimation of these drugs in combined dosage forms.  相似文献   

16.
A rapid and simple high performance liquid chromatography (HPLC) method was developed and validated for determination of levosulpiride in human plasma. After extraction with ethylacetate/methylene chloride (5:1, v/v), analysis of levosulpiride in plasma samples was carried out using a reverse phase C18 column with fluorescence detector (maximum excitation at 300 nm and maximum emission at 365 nm) for separation and quantification. A mixture of methanol-20 mM phosphate buffer (pH 3.5, 16:84, v/v) was used as a mobile phase. The method was specific and sensitive with a limit of quantification of 5 ng/ml. This HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis in the concentration range of 5-150 ng/ml. The relative standard deviation (R.S.D.) in inter- and intra-day validation were 8.16-19.75 and 3.90-11.69%, respectively. In stability tests, levosulpiride in human plasma was stable during the storage and assay procedure. The method was applied to the bioequivalence study of two levosulpiride tablet formulations (25 mg) after a single oral administration.  相似文献   

17.
A simple reverse phase liquid chromatographic method has been developed and subsequently validated for simultaneous determination of salbutamol sulphate and bromhexine hydrochloride. The separation was carried out using a mobile phase consisting of acetonitrile, methanol and phosphate buffer, pH 4 in the ratio 60:20:20 v/v. The column used was SS Wakosil-II C-18 with a flow rate of 1 ml/min and UV detection at 224 nm. The described method was linear over a concentration range of 10-110 μg/ml and 20-140 μg/ml for the assay of salbutamol sulphate and bromhexine hydrochloride, respectively. The mean recovery was found to be 95-105% for salbutamol sulphate and 96.2-102.1% for bromhexine hydrochloride when determined at five different levels.  相似文献   

18.
A simple, precise and accurate isocratic reverse-phase liquid chromatography method with programmed wavelength detection has been validated to quantify DRF-4367 and Phenol red, simultaneously for application in rat in situ single pass intestinal perfusion study to assess intestinal permeability of DRF-4367, a novel cox-2 inhibitor. The method was validated on RP C-18 analytical column. Mobile phase consisted of sodium dihydrogen orthophosphate (pH 3.2, 0.01 M)-acetonitrile-methanol (30:50:20, v/v/v). The developed method has a short run time of 12 min with a flow rate of 1.0 ml/min. The injector volume was set to 20 microl and acquisition was carried out using a PDA detector while processing was done by timed wavelength extraction. The percentage R.S.D. and recovery in all studies indicated that the method was suitable for the intended purpose. The validated method was found to be linear and precise in the working range. Suitability of storage at cold temperature was ensured along with complete sample recovery.  相似文献   

19.
A simple, specific and sensitive reverse phase high performance liquid chromatographic method was developed and validated for simultaneous determination of ezetimibe and simvastatin from pharmaceutical dosage forms. The method uses C18 ODS Hypersil column and isocratic elution. The mobile phase composed of acetonitrile:phosphate buffer (pH 4.5, 0.01M) in the ratio of 65:35 v/v was used at a flow rate of 1.0 ml /min. UV detector was programmed at 232 nm for first 10 min and at 238 nm for 10 to 20 min. All the validation parameters were in acceptable range. The developed method was effectively applied to quantitate amount of ezetimibe and simvastatin from tablets. The method was also applied suitably for determining the degradation products of ezetimibe and simvastatin.  相似文献   

20.
A new and accurate chiral liquid chromatographic method was developed for the enantiomeric resolution of Rivastigmine hydrogen tartarate, (-)S-N-ethyl-3-[(1-dimethyl-amino)ethyl]-N-methylphenyl-carbamate hydrogen tartarate, a cholinesterase inhibitor in bulk drugs. The enantiomers of Rivastigmine hydrogen tartarate were baseline resolved on a Chiralcel OD-H (250 mm x 4.6 mm, 5 microm) column using a mobile phase system containing hexane: isopropanol: trifluoroacetic acid (80:20:0.2, v/v/v). The resolution between the enantiomers was not less than four and interestingly distomer was eluted prior to eutomer in the developed method. The presence of trifluoroacetic acid in the mobile phase has played an important role in enhancing chromatographic efficiency and resolution between the enantiomers. The developed method was extensively validated and proved to be robust. The limit of detection and limit of quantification of (R)-enantiomer were found to be 500 and 1500 ng/ml, respectively for 10 microl injection volume. The percentage recovery of (R)-enantiomer was ranged from 95.2 to 104.3 in bulk drug samples of Rivastigmine hydrogen tartarate. Rivastigmine hydrogen tartarate sample solution and mobile phase were found to be stable for at least 48 h. The proposed method was found to be suitable and accurate for the quantitative determination of (R)-enantiomer in bulk drugs. Chiralcel OJ-H column can also be used as an alternative for the above purpose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号