首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

OBJECTIVE:

Distinct aspects can influence the complication rates of computed tomography‐guided percutaneous fine needle aspiration biopsy of lung lesions. The purpose of the current study is to determine the influence of radiological techniques and clinical characteristics in predicting complications from this procedure.

SUBJECTS AND METHODS:

A retrospective study was developed involving 340 patients who were submitted to a consecutive series of 362 computed tomography‐guided fine needle aspiration biopsies of lung lesions between July 1996 and June 2004, using 22‐gauge needles (CHIBA). Variables such as the radiological characteristics of the lesions, secondary pulmonary radiological findings, co‐morbidities, and aspects concerning the procedure were studied.

RESULTS:

The diameters of the lung lesions varied from 9 to 140 mm, with a mean of 51.5 ± 24.3 mm and median of 40 mm. The depth of the lesions varied from 10 mm to 130 mm, with a mean of 44 ± 20.9 mm, and median median of 52 mm. Complications occurred in 52 (14.4%) cases, pneumothorax being the most frequent, with 40 (11.1%) cases, followed by hemoptisis with 7 (1.9%) cases, and hematoma with 4 (1.1%) cases. Lesions that did not contact the pleura, with normal pulmonary tissue interposition between lesion and pleura, had higher complication rates, with 22 (22%) cases, than lesions that contact the pleura, with 6 (9%) cases, with a statistically significant difference (p  =  0.03).

CONCLUSIONS:

CT‐guided percutaneous fine needle aspiration biopsy of lung lesions had a lower rate of complications in our study and presented more rates of complications on lesions that lack pleural contact.  相似文献   

2.

OBJECTIVES:

To evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions.

METHODS:

Eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion.

RESULTS:

In all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion-weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]×10-3 mm2/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymomas.

CONCLUSION:

Functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques.  相似文献   

3.

OBJECTIVES:

To evaluate the performance of fine and cutting needles in computed tomography guided-biopsy of lung lesions suspicious for malignancy and to determine which technique is the best option for a specific diagnosis.

METHODS:

This retrospective study reviewed the data from 362 (71.6%) patients who underwent fine-needle aspiration biopsy and from 97 (19.7%) patients who underwent cutting-needle biopsy between January 2006 and December 2011. The data concerning demographic and lesion characteristics, procedures, biopsy sample adequacy, specific diagnoses, and complications were collected. The success and complication rates of both biopsy techniques were calculated.

RESULTS:

Cutting-needle biopsy yielded significantly higher percentages of adequate biopsy samples and specific diagnoses than did fine-needle aspiration biopsy (p<0.05). The sensitivity, specificity, and accuracy of cutting-needle biopsy were 93.8%, 97.3%, and 95.2%, respectively; those of fine-needle aspiration biopsy were 82.6%, 81.3%, and 81.8%, respectively (all p<0.05). The incidence of pneumothorax was higher for fine-needle aspiration biopsy, and that of hematoma was higher for cutting-needle biopsy (both p<0.05).

CONCLUSIONS:

Our experience using these two techniques for computed tomography-guided percutaneous biopsy showed that cutting-needle biopsy yielded better results than did fine-needle aspiration biopsy and that there was no significant increase in complication rates to indicate the best option for specific diagnoses.  相似文献   

4.

Background

Solitary lateral cervical cystic mass is an uncommon presentation of papillary thyroid carcinoma.

Objectives

To report our recent experience in the diagnosis and management of papillary thyroid carcinoma presenting as a lateral neck cyst.

Methods

Patients who had papillary thyroid carcinoma and presented as a painless lateral neck cyst at the Department of Surgery, Al-Ain Hospital, from April 2005 to June 2009 were retrospectively studied. Their clinical presentation, diagnosis and management were reviewed.

Results

Five patients were studied. No thyroid nodules were clinically palpable in all patients. Fine needle aspiration cytology from the cyst was positive for papillary thyroid carcinoma in three patients (60 percent). Two patients were diagnosed after excisional biopsy. Three patients had total thyroidectomy with modified radical neck dissection and postoperative radioactive iodine ablation. Two patients preferred to travel overseas for treatment. Thyroid histopathological examination has shown papillary thyroid carcinoma in all operated patients with multiple microscopic foci in two of them. This was associated with multiple bilateral cervical lymph node involvement.

Conclusions

Metastatic papillary thyroid carcinoma presenting as a neck cyst is a diagnostic challenge. Excisional biopsy is indicated if fine needle aspiration cytology was inconclusive so as to rule out malignancy.  相似文献   

5.

Purpose

To assess the incidence of thyroid malignancy in an adult population screened by high-resolution ultrasonography at a medical screening center and to compare the clinical and pathological features of screen-detected thyroid carcinomas to symptomatic overt thyroid carcinomas.

Materials and Methods

We calculated the prevalence of screen-detected thyroid cancer at a medical screening center using high-resolution ultrasonography and fine needle aspiration. We then compared the clinical and pathological features of screen-detected thyroid cancers (n = 46) to clinical symptomatic thyroid cancers (n = 157). We evaluated age, gender, size, perithyroidal extension, lymphovascular extension, stage, histological lymph node metastasis, and the type of cancer. We also compared the above findings of micropapillary carcinomas to papillary thyroid carcinomas that were larger than 1 cm in diameter.

Results

Screen-detected thyroid nodule patients were 2,747 (37%) of 7,491 patients. Nodules selected for fine needle aspiration were 658 and cytology confirmed malignancy were 79 (12%) nodules. When screen-detected thyroid cancers (n = 46) were compared to symptomatic overt thyroid cancers (n = 157), only statistically significant factor was size (p = 0.002). Papillary thyroid carcinomas that were larger than 1 cm had more frequent capsular invasion (p = 0.000) and a higher stage (p = 0.027), and a higher prevalence of lymph node metastases (p = 0.002).

Conclusion

Screen-detected thyroid cancers should be managed as same as symptomatic thyroid cancers in respect to size, and an assessment should strictly be based on the ultrasound features and fine needle aspiration biopsy findings.  相似文献   

6.

Background

Endoscopic ultrasound guided fine needle aspiration biopsy (EUS‐FNA) has proven to be an effective diagnostic modality for the detection and staging of pancreatic malignancies. In recent years EUS‐FNA has also been used to diagnose lesions of non‐pancreatic sites such as structures in close proximity to the gut wall within the mediastinum, abdomen, pelvis and retro‐peritoneum.

Aims

To evaluate experience with EUS‐FNA of non‐pancreatic sites at a large university medical centre.

Methods

The study cohort included 234 patients who underwent EUS‐FNA of 246 lesions in non‐pancreatic sites (122 peri‐pancreatic and coeliac lymph nodes; 9 peri‐pancreatic masses; other sites: mediastinum 12, gastric 25, liver 27, oesophagus 17, duodenum/colon/rectum 15, retro‐peritoneum 8, lung 7, miscellaneous 4).

Results

The cytology diagnoses were classified as non‐neoplastic/reactive in 82 (33%), atypical/suspicious for malignancy in 25 (10%), malignant in 86 (35%) and non‐diagnostic in 53 (22%) cases. Surgical pathology follow‐up was available in 75 (31%) cases. Excluding the non‐diagnostic cases there were 7 false negative and 3 false positive cases. The sensitivity, specificity and positive predictive value of EUS‐FNA in the diagnosis of lesions of non‐pancreatic sites was 92%, 98% and 97%, respectively.

Conclusions

EUS‐FNA can be effectively used as a diagnostic modality in the diagnosis of lesions from non‐pancreatic sites.  相似文献   

7.

Purpose

The purpose was to compare the frequency of metastatic and nonmetastatic lymph nodes diagnosed by fine needle aspiration biopsy cytology (FNAC) and thyroglobulin concentration from fine needle aspiration biopsy washout fluid (FNAB-Tg) in an indeterminate range (0.2-100 ng/mL), and to evaluate the most appropriate threshold value of FNAB-Tg in an indeterminate range.

Materials and Methods

We performed ultrasound-guided FNAB and FNAB-Tg in suspicious metastatic cervical lymph nodes of papillary thyroid carcinoma and performed surgery. Ninety-five lymph nodes with indeterminate values of FNAB-Tg ranging from 0.2-100 ng/mL in ninety-two patients were included in this study. The diagnostic performances in multiple Tg levels (0.7, 1.0, 5.0, 10.0, 20.0, 50.0) were evaluated to compare with FNAB cytology using sensitivity, specificity, and accuracy with area under the curve (AUC) analysis.

Results

Forty-two were metastatic lymph nodes and fifty three were nonmetastatic lymph nodes. FNAB-Tg ranged from 0.22 to 90.9 ng/mL in metastatic lymph nodes (mean; 34.3±33.3 ng/mL) and 0.20 to 56.7 ng/mL in nonmetastatic lymph nodes (mean; 4.9±11.1 ng/mL) (p<0.001). The most excellent diagnostic performance was displayed in 5 ng/mL of FNAB-Tg with AUC of 0.76, sensitivity, specificity, accuracy, 69.0, 83.0, and 76.8, respectively. However, there was no significant difference from 10 ng/mL FNAB.

Conclusion

We ascertained that 5 ng/mL yielded the most excellent diagnostic performance among FNAB-Tg levels in the present setting with a large series with the indeterminate range (0.2-100 ng/mL) of FNAB-Tg values. These results need additional confirmation under different laboratory conditions.  相似文献   

8.

Purpose

Pseudoangiomatous stromal hyperplasia (PASH) of the breast is a rare, benign condition that can be mistaken as a fibroadenoma on an ultrasound examination or as a low-grade angiosarcoma on a histological examination. The objective of this study was to evaluate the ultrasound features and to present biopsy methods to correctly identify PASH.

Patients and Methods

We retrospectively reviewed the data of 55 women who were diagnosed with PASH of the breast. Ultrasound features were evaluated according to the Breast Imaging Reporting and Data System (BI-RADS; American College of Radiology). The diagnostic ability of different biopsy methods such as core needle biopsy, vacuum-assisted biopsy and excisional biopsy were analyzed with the final histopathological results of surgical specimens.

Results

PASH presented as a circumscribed solid mass, with hypoechoic texture with or without heterogeneity, and a parallel orientation. The features of small, internal cysts or vascular channels and no calcifications can be used to differentiate the lesions from fibroadenomas. A core needle biopsy misdiagnosed PASH in 13 cases out of 28 cases and vacuum-assisted biopsy correctly identified PASH in all 3 cases.

Conclusion

Ultrasound features of PASH should be noted when performing a biopsy. For inconclusive cases of PASH, an excisional biopsy followed by an initial core biopsy should be performed.  相似文献   

9.

Introduction

Isolated tuberculous epididymo-orchitis may closely mimic testicular tumour particularly in patients with no history of systemic TB thereby presenting a diagnostic and treatment challenges.

Case report

A 44-year old man presented with 4 months history of left scrotal mass and had left orchidectomy following a presumptive diagnosis of testicular tumour. Histopathological diagnosis of testicular tuberculosis was subsequently made. Although the patient was thereafter referred for antituberculosis treatment at the local tuberculosis treatment centre, he defaulted after commencing treatment.

Conclusion

Adequate evaluation of patients with testicular mass by means of abdominal and scrotal ultrasound coupled with fine needle aspiration cytology is critical to diagnostic accuracy, optimal treatment and possibility of avoiding surgery in those with testicular tuberculosis.  相似文献   

10.

Purpose

To investigate the ultrasonographic (US) features of anaplastic thyroid cancer (ATC) and the diagnostic performance of US-guided fine needle aspiration biopsy (FNAB) therein.

Materials and Methods

Eighteen cases of ATC diagnosed between January 2001 and May 2011 were included. FNAB was performed in all cases. Initial FNAB results were divided into three groups: 1) the cytological ATC group, cytological diagnosis of ATC; 2) the underestimated group, cytological diagnoses of malignancy other than ATC; and 3) the false negative group, cytological diagnoses of atypical, benign and non-diagnostic lesions. We retrospectively reviewed US findings and compared treatment modalities between each group.

Results

Among the 18 patients, there were nine in the initially cytological ATC group, four in the underestimated group and five in the false negative group. The most common US features of ATC were a solid (64.7%) and irregular shaped (88.2%) mass with lymph node involvement (76.4%). However, except for lymph node involvement (p=0.003), US findings for each group were not statistically different. The initial cytological diagnostic accuracy of ATC was 50% (9/18). Surgery was performed less in the ATC group (11%) and the false negative group (20%) than the underestimated group (75%).

Conclusion

The US features of ATC were not especially different from other types of aggressive thyroid cancer. A correct diagnosis of ATC by initial US-FNAB was made in 50% of the patients, which is significant in that therapeutic surgery can be undertaken in lower numbers if correctly diagnosed.  相似文献   

11.
12.

Background

The estrogen receptor (ER), progesterone receptor (PR), and HER2 profile of a primary breast carcinoma plays a significant role in patient management and treatment. Because of the increasing utilization of neoadjuvant chemotherapy or hormone therapy, surgically-resected carcinomas often show marked treatment effect. The aim of this study was to compare immunohistochemical (IHC) profiles (ER, PR, HER2, HER2 FISH) of primary breast carcinomas before and after neoadjuvant chemotherapy to assess the subsequent effects on hormone receptor status.

Design

Primary breast carcinomas from 38 female patients treated with neoadjuvant therapy after needle core biopsy or fine needle aspiration diagnosis were included. Histologic data was collected for each case, including site, type, grade, tumor size (cm), pre- and post- neoadjuvant treatment IHC panel (ER, PR, HER2), and fluorescence in-situ hybridization (FISH) for HER2.

Results

Of the 38 carcinomas studied, 45 % were positive for ER by IHC both pre- and post- neoadjuvant treatment (P=1.00). IHC studies for PR in these 38 patients showed 37% positivity for PR pre-neoadjuvant therapy and 21% positivity post-treatment (p=0.03). For 37 patients with HER2 IHC, 32% were positive pre-treatment, and 22% were positive post-treatment (P = 0.20). For 7 patients, HER2 FISH was positive in 71% pre-therapy and in 57% post-treatment (P=0.32).

Conclusions

Profiles for ER, HER2 IHC, and HER2 FISH were not significantly different in primary breast carcinomas before and after neoadjuvant chemotherapy. Further investigation is warranted to assess reproducibility of technique and investigate clinical implications of significant loss of PR status in treated patients.  相似文献   

13.

Purpose

To evaluate malignancy risk according to ultrasound (US) features and size change on follow-up US in mixed echoic thyroid nodules and to suggest management guidelines thereof.

Materials and Methods

Among patients who underwent US-guided fine needle aspiration biopsy, 316 mixed echoic nodules in 303 patients were included after excluding the patients with pure solid or cystic nodules or without further cytopathologic evaluation. We evaluated malignancy risk according to US features and changes in size and shape on follow-up US.

Results

The malignancy rate was 31.6% (6 of 19) for nodules with suspicious US features and 2.7% (8 of 297) for nodules without suspicious US features (p<0.001). Among 265 nodules with no suspicious US features and initial benign cytology, 15 nodules with suspicious US change and decreased size, 25 nodules with no suspicious US change and increased size, and 225 nodules with no suspicious US change and no change in size were observed on follow-up USs. The malignancy risk thereof was 0%, 0% and 0.4%, respectively (p=1.000).

Conclusion

Mixed echoic nodules with no suspicious US features and benign cytology can be followed up using US, as they revealed very low malignancy rates, even if they showed growth on follow-up US.  相似文献   

14.

Purpose

To evaluate the concordance of cancer location of the tissue mapping from a mechanical pressure transducer with magnetic resonance imaging (MRI) scans.

Materials and Methods

A total of 60 indentations were performed on 5 prostate specimens obtained after radical prostatectomy utilizing a robotic indentation system. The mechanical elastic moduli of suspected malignant lesions were calculated and mapped, and their locations were compared with suspicious areas of malignancy on MRI scans.

Results

The concordance rate between the location mapping from the robotic indentation system and MRI scans results was 90.0% (54/60). The sensitivity and specificity of the robotic indentation system were 87.9% (29/33) and 92.6% (25/27), respectively. The positive predictive value and negative predictive value were 93.5% (29/31) and 93.1% (27/29), respectively.

Conclusion

The locations of malignant lesions derived from our robotic indentation system correlated strongly with the locations of suspected areas of malignancy on MRI scans. Our robotic system may provide a more targeted biopsy of the prostate than conventional non-targeted systemic biopsy, possibly improving the diagnostic accuracy of prostatic biopsies for cancer.  相似文献   

15.

Background

Current UK melanoma guidelines do not support the initial diagnostic excision biopsy of pigmented lesions in primary care, although this is standard in other countries such as Australia. Previous research in Northeast Scotland found that initial diagnostic excision biopsies in primary care that prove to be melanoma were no more likely to be incomplete than those performed in secondary care, but data on longer-term outcomes were not available.

Aim

To determine whether initial diagnostic excision biopsy of cutaneous melanoma in primary versus secondary care leads to poorer survival and increased morbidity.

Design and setting

Analysis of a linked dataset comprising pathological data from melanoma cases diagnosed in Northeast Scotland between 1991 and 2007, the General Registry Office (Scotland) death registry, and an NHS Scotland episode of care database.

Method

Patient data from three sources were matched using the Community Health Index (CHI) number. Cox proportional hazards regression, with robust standard error estimates, was used to examine the hazard ratio (95% confidence interval) of key mortality and morbidity outcomes based on excision in primary versus secondary care. Analysis was conducted before and after adjustment for operator and patient-level factors, using a multilevel approach.

Results

Patients receiving their initial diagnostic excision biopsy for melanoma in primary versus secondary care were no more likely to be dead, or to have died of metastatic malignant melanoma. Patients who had their initial diagnostic excision biopsy for melanoma in primary care had significantly fewer subsequent hospital admissions and spent fewer days in hospital.

Conclusion

These findings suggest that initial diagnostic excision biopsy of melanoma in primary care does not lead to poorer long-term outcomes.  相似文献   

16.

Background

The lymphoreticular system plays a major role in both the innate and adaptive immune responses. This study reviews retrospectively cases of lymphoreticular diseases seen at a tertiary institution in Nigeria.

Materials and Methods

This is a retrospective study in which biopsies from the bone marrow, spleen, lymph nodes and extranodal lymphoid tissues reported within a period of 16 years were reviewed with respect to age, sex and pathological diagnosis. Statistical analysis was performed for differences in proportion using Chi square by SPSS version 12.

Results

Nine hundred and forty four cases comprising 559 biopsies from lymph nodes and extranodal lymphoid tissues, 272 bone marrow biopsies and 113 spleen biopsies were studied. Non Hodgkin''s lymphoma (NHL) and tuberculosis were the most common lesions in lymph nodes and extranodal lymphoid tissues. The axillary and cervical nodes accounted for most cases of metastasis. Breast cancer accounted for the majority of metastasis to lymph nodes.The most common pathological changes in bone marrow were NHL and reactive hyperplasia. Patients with chronic lymphocytic leukaemia (CLL) had the highest mean age, which was significantly higher than in those with NHL (p=.001, 95% confidence interval −27.91 to −7.76). The most common finding in the spleen was splenic rupture and haemoperitoneum from road traffic accident.

Conclusion

NHL and tuberculosis should be high on the list of differential diagnosis of lymphadenopathy in Nigerians. Whereas trauma from RTA was the major reason for splenectomy in Nigerians, in the elderly splenic biopsy would likely show CLL.  相似文献   

17.

Purpose

To analyze which sonographic features of thyroid nodules with macrocalcifications were predictable of thyroid malignancy.

Materials and Methods

We reviewed sonographic findings of 854 macrocalcified thyroid nodules in patients who underwent fine needle aspiration biopsy between December 2009 and January 2011. There were 171 non-diagnostic aspirations, 34 nodules with category 3, 4, 5 based on Bethesda system, which were not confirmed by surgery, and these nodules were excluded from the analysis. Sonographic characteristics of the macrocalcifications including its thickness, interruption, and existence of soft tissue rim outside the macrocalcification were analyzed. Other sonographic characteristics of nodules such as shape, margin, composition, echo pattern, vascularity, and underlying parenchymal echogenicity were also evaluated. The correlation of sonographic features with cytopathologic results and the diagnostic performance of sonographic features for the prediction of malignancy were analyzed.

Results

Among 649 nodules, 179 (27.6%) nodules were malignant and 470 (72.4%) nodules were benign. Among the features of the macrocalcification, interruption, irregular thickness, or the presence of soft tissue outside calcification rim were associated with malignancy (p<0.001). A high sensitivity and negative predictive values for the prediction of malignancy was found in sonographic characteristics of irregular thickness (92.2% and 91.0%, respectively) and the presence of soft tissue (88.5% and 88.8%, respectively).

Conclusion

Sonographic characteristics of macrocalcification such as interruption, irregular thickness and the presence of soft tissue rim were associated with malignancy in thyroid nodules with macrocalcifications.  相似文献   

18.

Purpose

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an accurate and minimally invasive technique used routinely for investigation of mediastinal and hilar lymphadenopathy. However, few studies have addressed its role in comparison to the traditional diagnostic approaches of transbronchial lung biopsy (TBLB), endobronchial biopsy (EBB), and bronchoalveolar lavage (BAL) in the diagnosis of sarcoidosis. We evaluated the usefulness of EBUS-TBNA in the diagnosis of sarcoidosis compared to TBLB, EBB, and BAL.

Materials and Methods

Consecutive patients with suspected sarcoidosis (stage I and II) on chest radiography and chest computed tomography were included. All 33 patients underwent EBUS-TBNA, TBLB, EBB, and BAL during the same session between July 2009 and June 2011. EBUS-TBNA was performed at 71 lymph node stations.

Results

Twenty-nine of 33 patients, were diagnosed with histologically proven sarcoidosis; two patients were compatible with a clinical diagnosis of sarcoidosis during follow-up; and two patients were diagnosed with metastatic carcinoma and reactive lymphadenopathy, respectively. Among 29 patients with histologically proven sarcoidosis in combination with EBUS-TBNA, TBLB, and EBB, only EBUS-TBNA and TBLB revealed noncaseating granuloma in 18 patients and one patient, respectively. The overall diagnostic sensitivities of EBUS-TBNA, TBLB, EBB, and BAL (CD4/CD8 ≥3.5) were 90%, 35%, 6%, and 71%, respectively (p<0.001). The combined diagnostic sensitivity of EBUS-TBNA, TBLB, and EBB was 94%.

Conclusion

EBUS-TBNA was the most sensitive method for diagnosing stage I and II sarcoidosis compared with conventional bronchoscopic procedures. EBUS-TBNA should be considered first for the histopathologic diagnosis of stage I and II sarcoidosis.  相似文献   

19.

AIM:

This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions.

METHODS:

A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, patients'' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed.

RESULTS:

There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant.

CONCLUSIONS:

The present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins.  相似文献   

20.
Cases of metastases to the thyroid gland seem to be increasing in recent years. The clinical and ultrasonographic findings of diffuse metastases have been sparsely reported. Thirteen cases of diffuse metastases to the thyroid gland were documented by thyroid ultrasonography-guided fine needle aspiration cytology between 2004 and 2013. We retrospectively reviewed the patients with diffuse thyroid metastases. The most common primary site was the lung (n=9), followed by unknown origin cancers (n=2), cholangiocarcinoma (n=1), and penile cancer (n=1). Eleven patients were incidentally found to have thyroid metastases via surveillance or staging FDG-PET. Other 2 patients were diagnosed during work-up for hypothyroidism and palpable cervical lymph nodes. On ultrasonography, the echogenicity of the enlarged thyroid gland was heterogeneously hypoechoic or isoechoic, and reticular pattern internal hypoechoic lines were observed without increased vascularity found by power Doppler ultrasonography (3 right lobe, 2 left lobe, and 8 both lobes). In the 8 patients who had involvement of both lobes, 3 had hypothyroidism. In conclusion, ultrasonographic finding of diffuse metastasis is a diffusely enlarged heterogeneous thyroid with reticular pattern internal hypoechoic lines. Thyroid function testing should be performed in all patients with diffuse thyroid metastases, especially those with bilateral lobe involvement.

Graphical Abstract

相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号