1.
A fast and robust methodology for in vivo T(2) mapping is presented. The approach is based on the partially spoiled steady state free precession technique recently proposed by Bieri et al. (Magn Reson Med 2011). The accuracy of this method was demonstrated in simulations and phantom experiments. Variations in skeletal muscle T(2) relaxation time have been correlated with cell damage and inflammatory response. Nonetheless, the lack of easily implementable, fast, accurate and reproducible methods has hampered the adoption of T(2) measurement as a noninvasive tool for skeletal muscle characterization. The applicability of the partially spoiled steady state free precession method for tissue characterization in muscle disease is illustrated in this work by several examples. Quantitative MRI, in particular T(2) mapping based on partially spoiled steady state free precession acquisitions, might provide objective markers of muscle damage and degenerative changes, and an alternative to serial muscle biopsies.  相似文献   

2.
3.
Spoiled gradient echo sequences can only reach a homogeneous steady state if sufficiently strong crusher gradients are used in combination with RF phase cycling (RF spoiling). However, the signal depends quite sensitively on the chosen phase increment ? and—lacking analytical solutions—numerical simulations must be used to study the transient and steady‐state magnetization. For the steady state an exact analytical solution is derived, which holds for arbitrary sequence and tissue parameters. Besides a considerably improved computation performance, the analytical approach enables a better understanding of the complicated dependence on ?. For short repetition times (TR) the regime of small ? turns out to be particularly interesting: It is shown that the typical ?c, where RF spoiling starts to become effective, is essentially inversely proportional to T2. This tissue dependence implies that contrasts can be considerably larger with partial spoiling (? ≈ ?c) than with conventional RF spoiling (? ? ?c). As an example, the uptake of contrast agents in tissues is investigated. For typical parameters a considerably improved contrast enhancement can be obtained, both theoretically and experimentally. Magn Reson Med, 2006. © 2005 Wiley‐Liss, Inc.  相似文献   

4.
5.
Variable flip angle T1 mapping and actual flip‐angle imaging B1 mapping are widely used quantitative MRI methods employing radiofrequency spoiled gradient‐echo pulse sequences. Incomplete elimination of the transverse magnetization in these sequences has been found to be a critical source of T1 and B1 measurement errors. In this study, comprehensive theoretical analysis of spoiling‐related errors in variable flip angle and actual flip‐angle imaging methods was performed using the combined isochromat summation and diffusion propagator model and validated by phantom experiments. The key theoretical conclusion is that correct interpretation of spoiling phenomena in fast gradient‐echo sequences requires accurate consideration of the diffusion effect. A general strategy for improvement of T1 and B1 measurement accuracy was proposed based on the strong spoiling regimen, where diffusion‐modulated spatial averaging of isochromats becomes a dominant factor determining magnetization evolution. Practical implementation of strongly spoiled variable flip angle and actual flip‐angle imaging techniques requires sufficiently large spoiling gradient areas (AG) in combination with optimal radiofrequency phase increments (?0). Optimal regimens providing <2% relative T1 and B1 measurement errors in a variety of tissues were theoretically derived for prospective in vivo variable flip angle (pulse repetition time = 15–20 ms, AG = 280–450 mT·ms/m, ?0 = 169°) and actual flip‐angle imaging (pulse repetition time1/pulse repetition time2 = 20/100 ms, AG1/AG2 = 450/2250 mT·ms/m, ?0 = 39°) applications based on 25 mT/m maximal available gradient strength. Magn Reson Med 63:1610–1626, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

6.
7.
A novel, fully 3D, high-resolution T(1) and T(2) relaxation time mapping method is presented. The method is based on steady-state imaging with T(1) and T(2) information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T(1) is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This T(1) information is combined with two refocused steady-state free precession (SSFP) images to determine T(2). T(1) and T(2) accuracy was evaluated against inversion recovery (IR) and spin-echo (SE) results, respectively. Error within the T(1) and T(2) maps, determined from both phantom and in vivo measurements, is approximately 7% for T(1) between 300 and 2000 ms and 7% for T(2) between 30 and 150 ms. The efficiency of the method, defined as the signal-to-noise ratio (SNR) of the final map per voxel volume per square root scan time, was evaluated against alternative mapping methods. With an efficiency of three times that of multipoint IR and three times that of multiecho SE, our combined approach represents the most efficient of those examined. Acquisition time for a whole brain T(1) map (25 x 25 x 10 cm) is less than 8 min with 1 mm(3) isotropic voxels. An additional 7 min is required for an identically sized T(2) map and postprocessing time is less than 1 min on a 1 GHz PIII PC. The method therefore permits real-time clinical acquisition and display of whole brain T(1) and T(2) maps for the first time.  相似文献   

8.
9.
Radiofrequency (RF)‐spoiled gradient‐echo imaging provides a signal intensity close to pure T1 contrast by using spoiler gradients and RF phase cycling to eliminate net transverse magnetization. Generally, spins require many RF excitations to reach a steady‐state magnetization level; therefore, when unsaturated flowing spins enter the imaging slab, they can cause undesirable signal enhancement and generate image artifacts. These artifacts can be reduced by partially saturating an outer slab upstream to drive the longitudinal magnetization close to the steady state, while the partially saturated spins generate no signal until they enter the imaging slab. In this work, magnetization evolution of flowing spins in RF‐spoiled gradient‐echo sequences with and without partial saturation was simulated using the Bloch equations. Next, the simulations were validated by phantom and in vivo experiments. For phantom experiments, a pulsatile flow phantom was used to test partial saturation for a range of flip angles and relaxation times. For in vivo experiments, the technique was used to image the carotid arteries, abdominal aorta, and femoral arteries of normal volunteers. All experiments demonstrated that partial saturation can provide consistent T1 contrast across the slab while reducing inflow artifacts. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.  相似文献   

10.
Variations in the intrinsic T(1) and T(2) relaxation times have been implicated in numerous neurologic conditions. Unfortunately, the low resolution and long imaging time associated with conventional methods have prevented T(1) and T(2) mapping from becoming part of routine clinical evaluation. In this study, the clinical applicability of the DESPOT1 and DESPOT2 imaging methods for high-resolution, whole-brain, T(1) and T(2) mapping was investigated. In vivo, 1-mm(3) isotropic whole-brain T(1) and T(2) maps of six healthy volunteers were acquired at 1.5 T with an imaging time of <17 min each. Isotropic maps (0.34 mm(3)) of one volunteer were also acquired (time <21 min). Average signal-to-noise within the 1-mm(3) T(1) and T(2) maps was approximately 20 and approximately 14, respectively, with average repeatability standard deviations of 46.7 ms and 6.7 ms. These results demonstrate the clinical feasibility of the methods in the study of neurologic disease.  相似文献   

11.
Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repetition times (TR) in the presence of B0 inhomogeneities, or near areas of magnetic susceptibility difference, such that the transverse magnetization experiences a net phase shift during the TR interval. This places constraints on the maximum spatial resolution that can be achieved without artifact. Here, a novel implementation of DESPOT2 is presented incorporating RF phase-cycling which acts to shift the spatial location of the bands, allowing reconstruction of a single, reduced artifact-image. The method is demonstrated in vivo with the acquisition of a 0.34 mm3 isotropic resolution T2 map of the brain with high precision and accuracy and significantly reduced artifact.  相似文献   

12.
There is increasing interest in quantitative T1 mapping techniques for a variety of applications. Several methods for T1 quantification have been described. The acquisition of two spoiled gradient‐echo data sets with different flip angles allows for the calculation of T1 maps with a high spatial resolution and a relatively short experimental duration. However, the method requires complete spoiling of transverse magnetization. To achieve this goal, RF spoiling has to be applied. In this work it is investigated whether common RF spoiling techniques are sufficiently effective to allow for accurate T1 quantification. It is shown that for most phase increments the apparent T1 can deviate considerably from the true value. Correct results may be achieved with phase increments of 118.2° or 121.8°. However, for these values the method suffers from instabilities. In contrast, stable results are obtained with a phase increment of 50°. An algorithm is presented that allows for the calculation of corrected T1 maps from the apparent values. The method is tested both in phantom experiments and in vivo by acquiring whole‐brain T1 maps of the human brain. Magn Reson Med 61:125–135, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

13.
14.
15.
16.
Magnetic resonance imaging (MRI) based on gradient echoes is used in a wide variety of imaging techniques and clinical applications. Gradient echo sequences form the basis for an essential group of imaging methods that find widespread use in clinical practice, particularly when fast imaging is important, as for example in cardiac MRI or contrast‐enhanced MR angiography. However, the term “gradient echo sequence” is somewhat unspecific, as even images acquired with the most common sequences employing the gradient echo for data acquisition can significantly differ in signal, contrast, artifact behavior, and sensitivity to, eg, flow. This is due to the different use of sequence timing and basic sequence building blocks such as spoiler gradients or specific radiofrequency (RF) pulse phase patterns. In this article the basic principles of gradient echo formation compared to spin echo imaging are reviewed and the properties of gradient echo imaging in its simplest form (TR ? T2) are described. Further, the most common three variants of fast gradient echo sequences (TR < T2), namely, unbalanced gradient echo, RF spoiled gradient echo, and balanced steady state free precession; are discussed. For each gradient echo sequence type, examples of applications exploiting the specific properties of the individual technique are presented. J. Magn. Reson. Imaging 2012;35:1274–1289. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
18.
A new technique for acquiring T2-weighted, balanced steady-state free precession (b-SSFP) images is presented. Based on the recently proposed transition into driven equilibrium (TIDE) method, T2-TIDE uses a special flip angle scheme to achieve T2-weighted signal decay during the transient phase. In combination with half-Fourier image acquisition, T2-weighted images can be obtained using T2-TIDE. Numerical simulations were performed to analyze the signal behavior of T2-TIDE in comparison with TSE and b-SSFP. The results indicate identical signal evolution of T2-TIDE and TSE during the transient phase. T2-TIDE was used in phantom experiments, and quantitative ROI analysis shows a linear relationship between TSE and T2-TIDE SNR values. T2-TIDE was also applied to abdominal and head imaging on healthy volunteers. The resulting images were analyzed quantitatively and compared with standard T2-weighted and standard b-SSFP methods. T2-TIDE images clearly revealed T2 contrast and less blurring compared to T2-HASTE images. In combination with a magnetization preparation technique, STIR-weighted images were obtained. T2-TIDE is a robust technique for acquiring T2-weighted images while exploiting the advantages of b-SSFP imaging, such as high signal-to-noise ratio (SNR) and short TRs.  相似文献   

19.
20.

Objective

To study the correlation between the T2 relaxation times of the patellar cartilage and morphological MRI findings of chondromalacia.

Methods

This prospective study comprises 50 patients, 27 men and 23 women suffering of anterior knee pain (mean age: 29.7, SD 8.3 years; range: 16–45 years).MRI of 97 knees were performed in these patients at 1.5 T magnet including sagittal T1, coronal intermediate, axial intermediate fat sat and T2 mapping. Chondromalacia was assessed using a modified version of Noyes classification. The relaxation time, T2, was studied segmenting the full thickness of the patellar cartilage in 12 areas: 4 proximal (external facet–proximal–lateral (EPL), external facet–proximal–central (EPC), internal facet–proximal–central (IPC), internal facet–proximal–medial (IPM), 4 in the middle section (external facet–middle–lateral (EML), external facet–middle–central (EMC), internal facet–middle–central (IMC), internal facet–middle–medial (IMM) and 4 distal (external facet–distal–lateral (EDL), external facet–distal–central (EDC), internal facet–distal–central (IDC), internal facet–distal–medial (IDM).

Results

T2 values showed a significant increase in mild chondromalacia regarding normal cartilage in most of the cartilage areas (p < 0.05), except in the internal distal facet (IDC and IDM), EPC, EDL, and IMM. Severe chondromalacia was characterized by a fall of T2 relaxation times with loss of statistical significant differences in comparison with normal cartilage, except in EMC and IMC, where similar values as mild chondromalacia were maintained (p < 0.05).

Conclusions

Steepest increase in T2 values of patellar cartilage occurs in early stages of patellar cartilage degeneration. Progression of morphologic changes of chondromalacia to more severe degrees is associated to a new drop of T2 relaxation times approaching basal values in most of the areas of the patellar cartilage, except in the central area of the middle section, where T2 values remain increased.  相似文献   