首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Banna virus (BAV, genus Seadornavirus, family Reoviridae) is an arbovirus suspected to be responsible for encephalitis in humans. Two genotypes of this virus are distinguishable: A (Chinese isolate, BAV-Ch) and B (Indonesian isolate, BAV-In6969) which exhibit only 41% amino-acid identity in the sequence of their VP9.The VP7 to VP12 of BAV-Ch and VP9 of BAV-In6969 were expressed in bacteria using pGEX-4T-2 vector. VP9 was chosen to establish an ELISA for BAV, based mainly on two observations: (i). VP9 is a major protein in virus-infected cells and is a capsid protein (ii). among all the proteins expressed, VP9 was obtained in high amount and showed the highest immuno-reactivity to anti-BAV ascitic fluid.The VP9s ELISA was evaluated in three populations: French blood donors and two populations (blood donors and patients with a neurological syndrome) from Malaysia, representing the region where the virus was isolated in the past.The specificity of this ELISA was >98%. In mice injected with live BAV, the assay detected IgG-antibody to BAV infection 21 days post-injection, which was confirmed by Western blot using BAV-infected cells.The VP9 ELISA permits to determine the sero-status of a population without special safety precautions and without any requirements to propagate the BAV. This test should be a useful tool for epidemiological survey of BAV.  相似文献   

2.
BACKGROUND: Eyach virus (EYAV) is a tick-borne virus belonging to genus Coltivirus, family Reoviridae. It was isolated in Germany and France and has been suspected to be responsible for neurological diseases in humans. To date, there has been no relatively rapid and relatively specific serological assay for EYAV. OBJECTIVES: To develop an ELISA for EYAV, suitable for epidemiological and/or diagnostic purposes. This ELISA should allow to distinguish between infections with EYAV and the related Colorado tick fever virus (CTFV). STUDY DESIGN: VP6, VP7 and VP12 of Eyach virus (the three proteins most divergent between EYAV and CTFV) were expressed in bacteria using the pGEX-4T-2 vector. A partial sequence of VP6 (designated pVP6) was chosen to develop an ELISA for detecting anti-EYAV IgG antibodies in serum. This choice was based on two observations: (i) the homologous VP7 protein of CTFV was successfully used as a target for detecting antibodies to CTFV (the VP7 showed the highest reactivity to an anti-CTFV antibody among all CTFV expressed proteins); (ii) to distinguish infection with EYAV from a CTFV infection: the expressed sequence was chosen within a region which is highly divergent (49% of amino acid identity) from the homologous VP7 sequence of CTFV. RESULTS AND CONCLUSIONS: pVP6 was shown to be the most reactive among the three expressed proteins. The elaborated pVP6 ELISA was evaluated with 340 sera of French blood donors, and found to exhibit a specificity of 100% (no false positives). Furthermore, no cross reaction was detected with antibody to CTFV, thus permitting us to distinguish between infections by either virus. The use of this recombinant protein for serological assays is a good alternative to the use of native EYAV antigen due to the extremely low productivity of the virus in cell culture, and the requirement for suckling mice. This ELISA will be useful to clarify the epidemiological status and the suspected pathogenicity of the virus.  相似文献   

3.
The full-length nucleoprotein of Crimean-Congo hemorrhagic fever virus (CCHFV; 482 amino acid residues) was expressed as a His-tagged recombinant protein (His-CCHFV rNP) in the baculovirus system. The His-CCHFV rNP was efficiently expressed in insect cells and purified by Ni(2+) column chromatography. Using this substrate, an immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) was developed. We evaluated the sensitivity and specificity of the IgG ELISA, using serum samples previously determined to be antibody positive or negative by immunofluorescence tests on CCHFV-infected Vero E6 cells. We found very good correlation between the two tests: 87% for the positive sera (13 of 15) and 99% for the negative sera (107 of 108). These results indicate that the new IgG ELISA using His-CCHFV rNP has high sensitivity and specificity for detecting CCHFV antibodies. The CCHF patients' sera with high titers reacted only with the NP fragment containing amino acid residues between 201 and 306 in Western blotting. It is known that amino acid homologies are high in this region among various isolates. Thus, it is expected that this ELISA can detect antibodies not only for Chinese strains of CCHFV but also for other strains circulating in the world. These results suggest that the IgG ELISA system developed with the recombinant CCHFV NP is a valuable tool for diagnosis and epidemiological investigations of CCHFV infections.  相似文献   

4.
A normalized enzyme-linked immunosorbent assay for the determination of immunoglobulin G antibodies to cytomegalovirus is described. The rapid assay involves three 30-min incubations and permits the quantitation of antibody levels with a single-specimen dilution in conjunction with a reference antibody preparation. The results obtained with the normalized enzyme-linked immunosorbent assay correlated closely with the results of complement fixation titrations and another commercially available enzyme-linked immunosorbent assay. The specificity of the procedure was further demonstrated by viral absorption, using cytomegalovirus from two different sources and other viral antigen preparations, including rubella and influenza. The reproducibility of the normalized test results is good and allows for greater uniformity of reporting on a day-to-day basis, as well as between laboratories.  相似文献   

5.
We have developed an indirect enzyme-linked immunosorbent assay for detection of anti-dengue virus (DENV) immunoglobulin G antibodies using four recombinant DENV envelope polypeptides as antigens, which demonstrated a sensitivity of 89.4% and a specificity of 93.3%. These easily produced antigens are a feasible, cost-effective alternative for generating reagents for dengue serological tests.  相似文献   

6.
An immunoglobulin M (IgM) capture enzyme immunoassay technique was adapted for the detection of antibody to Colorado tick fever virus in sera from 84 individuals for whom diagnosis had been confirmed by virus isolation or neutralization test. Titers were compared with those for IgG and neutralizing antibodies in these Colorado tick fever cases. IgM antibody titers were higher than neutralizing antibody titers, but neither appeared until 1 to 2 weeks after the onset of illness. Neutralizing antibodies were detected earlier than IgM antibodies, and both were detected with greater frequency than IgG antibodies. Late-convalescent-phase sera contained both neutralizing and IgG antibodies, but IgM was all but undetectable by 2 months after onset. Although the neutralization test may remain the serological test of choice, the enzyme immunoassay for IgM antibody offers a simple and more rapid method of serodiagnosis; the enzyme immunoassay is, however, less sensitive than the neutralization test. Furthermore, because there was a sharp decline in IgM antibody after 45 days, the presence of IgM antibody in a single serum sample provides a basis for the presumptive serodiagnosis of recent Colorado tick fever virus infection.  相似文献   

7.
The microenzyme-linked immunosorbent assay (ELISA) for the detection of immunoglobulin M and G (IgM, IgG) antibodies to Legionella pneumophila serogroup 1 antigens was evaluated. IgM antibodies were measured by both double-sandwich and single-sandwich techniques. These assays were compared with the previously standardized indirect immunofluorescence test in four groups of subjects: (i) pneumonia patients with culture-proven Legionnaires disease with serogroup 1 isolates, (ii) pneumonia patients with serogroup 1 organisms detected by direct immunofluorescence testing of respiratory secretions but without culture confirmation, (iii) pneumonia patients with negative culture and direct immunofluorescence tests, and (iv) healthy hospital employees. In addition, the sensitivity and specificity of the IgG ELISA were evaluated with larger groups of controls and Legionnaires disease patients. The ELISA was more sensitive than the indirect immunofluorescence test. However, it detected antibody rises in pneumonia patients without culture or direct immunofluorescence evidence of L. pneumophila serogroup 1 infection, thereby suggesting that the specificity of the ELISA was slightly lower than that of the indirect immunofluorescence test. The double-sandwich ELISA was a sensitive method for detecting IgM antibodies and, as previously reported, appeared to be free from interference by rheumatoid factor. IgM anti-Legionella antibodies detected by the ELISA appeared earlier and were less persistent than IgG antibodies. In addition, the IgM ELISA was useful in detecting antibodies in necropsy serum samples obtained from patients dying acutely of Legionnaires disease. The data presented show that the ELISA is a reliable method for the detection of specific anti-Legionella antibodies.  相似文献   

8.
Measles is a highly contagious respiratory virus infection, with typical clinical symptoms including maculopapular rash, fever, cough, coryza, and conjunctivitis. Despite implementation of widespread vaccination programs throughout the world, the rates of global morbidity and mortality are still considerable. This study was performed to design a reliable indirect enzyme-linked immunosorbent assay (ELISA) to measure measles-specific immunoglobulin M (IgM). First, human IgM was purified, and then an anti-IgM antibody was produced in rabbits and purified in a multistep process. The rabbit IgG against human IgM was conjugated with peroxidase. Measles virus-infected Vero cells produced viral antigen. One hundred serum samples from infants of 9 to 18 months of age, mostly vaccinated, were evaluated for determining the presence of specific IgM antibodies against measles virus. The samples were also evaluated for neutralizing antibodies against measles virus by a microneutralization test (MNT). By comparing the results of the ELISA with those of MNT, it was demonstrated that ELISA had a sensitivity and specificity of 100 and 92%, respectively. On the other hand, when the results obtained by our ELISA system were compared with those of an imported measles virus IgM ELISA kit (EIAgen; Adaltis Italia SPa, Bologna, Italy), a high level of agreement was shown (k = 0.926).  相似文献   

9.
An antibody capture enzyme-linked immunosorbent assay (ELISA) that uses horseradish-peroxidase-labeled antigen for the detection of immunoglobulin G (IgG) antibodies to cytomegalovirus (CMV) is described. A microtiter plate was coated with anti-human IgG and consecutively incubated with serum specimens, enzyme-labeled CMV antigen made from CMV-infected cell nuclei, and substrate. The CMV IgG antibody content was determined spectrophotometrically and expressed as absorbance. Furthermore, to reveal any nonspecific reactions, all sera were tested against an enzyme-labeled control antigen made from uninfected cell nuclei. The problem with nonspecific reactions was small and was circumvented by the addition of unlabeled control antigen to the conjugates. For epidemiological studies the test was not as sensitive as other serological tests. On the other hand, the IgG antibody capture ELISA was highly sensitive for detecting the serological antibody response in patients with primary and recurrent CMV infections. Thus, one positive serum remained positive at a serum dilution of 1:10(7). The specificity of the test was shown by a blocking experiment and by testing 126 complement fixation-positive sera, of which 97% were positive. There was a rather good correlation between the complement fixation test and the IgG antibody capture ELISA (rs = 0.79, P less than 0.001). The test is especially useful when tests for CMV antibodies of the IgM, IgA, and IgE classes are run by similar antibody capture ELISAs, since the same procedure and conjugate are used.  相似文献   

10.
Chlamydia trachomatis causes a wide range of infections in adults and conjunctivitis and pneumonia in neonates. The complement fixation test for chlamydial antibody is broadly reactive, but possesses low sensitivity, whereas the microimmunofluorescence test is highly sensitive, but technically difficult to perform. A simple, rapid enzyme-linked immunosorbent assay (ELISA) has been developed for the measurement of immunoglobulin G (IgG) and IgM antibodies to C. trachomatis. Wells of microtiter plates were coated with Renografin-purified elementary bodies (serotype L2) grown in cycloheximide-treated McCoy cells, and serum antibody was detected with peroxidase-labeled goat antihuman IgG and IgM antibody. Of 41 sera tested from patients with lymphogranuloma venereum, pelvic inflammatory disease, cervicitis, or urethritis there was a 90 and 63% correlation of positive results for IgG and IgM, respectively, by microimmunofluorescence and ELISA. Of the positive correlates, ELISA titers were up to 128 times higher than microimmunofluorescence titers for IgG and IgM. The ELISA detected no false-positive results, but missed two positive results for IgG. Both of these sera were reactive against serotypes C and J, suggesting that the ELISA with LGV L2 antigen may not measure antibodies to serotypes within the C serogroup. The IgM ELISA detected 7 negative and 4 positive results not detected by the microimmunofluorescence test. Of four paired sera examined by ELISA, three showed a fourfold rise in IgG antibody titer, and one showed a twofold rise. Further evaluation of this ELISA will be required to determine how useful it will be in seroepidemiological studies and as a diagnostic tool.  相似文献   

11.
A chemiluminescent enzyme-linked immunosorbent assay (CELISA) was developed for detecting human immunoglobulin G and herpes simplex viral antigen. A comparison of CELISA with a conventional absorptiometric detection system showed that CELISA was 100 times more sensitive than absorptiometry for the measurement of human immunglobulin G. Similarly, CELISA detected as few as 40 plaque-forming units of herpes simplex virus in contrast to 2,500 plaque-forming units detected by absorptiometry. Of 18 specimens which were positive for herpes simplex virus type 1 by isolation in tissue culture, 15 (83%) were detected by CELISA within a few hours; in certain cases, several days were necessary for detection of virus by isolation techniques.  相似文献   

12.
Rift Valley fever virus (RVFV) is an important human and animal pathogen in Africa and has been responsible for infections in travelers. Because of the aerosol infectivity and risk of dissemination of the virus, a need exists for simple, safe, serological tests for diagnosis. An enzyme-linked immunosorbent assay (ELISA) was developed to detect RVFV-specific immunoglobulins (immunoglobulin G [IgG] and IgM). In the test, a betapropiolactone-inactivated, sucrose-acetone-extracted, suckling mouse liver RVFV antigen was captured by mouse RVFV antibodies adsorbed to polystyrene plates. The test sample (human serum) was then added, and the binding of specific antibodies was indicated by alkaline phosphatase-conjugated swine anti-human IgG or IgM. A mu-capture IgM ELISA was also developed by using polystyrene plates coated with goat anti-human IgM incubated successively with serum sample, RVFV antigen, and indicator antibodies. The ELISA for RVFV-specific IgG proved to be more sensitive than hemagglutination inhibition or complement fixation tests and almost as sensitive as the plaque reduction neutralization test in detecting specific antibodies in human sera after vaccination. The two ELISA IgM tests could detect specific IgM antibodies during the first 6 weeks after RVFV vaccination. Three injections of inactivated vaccine were given on days 0, 6 to 8, and 32 to 34. ELISA IgM values for sera obtained on days 6 to 8 were negative or in the lower range of significance, on days 32 to 34 they were strongly positive, and on days 42 to 52 they were waning. Later sera were negative. The plague reduction neutralization test was negative on days 6 to 8 but rose progressively in later samples. These findings suggest that the three doses of RVFV vaccine induce a prolonged primary antibody response. The ELISA IgM could become an important tool for early diagnosis in acute human infection. A number of African sera, some of which were positive for RVFV by plaque reduction neutralization test, were also tested by ELISA IgG. There was good agreement between both tests.  相似文献   

13.
An enzyme-linked immunosorbent assay for the detection of immunoglobulin M (IgM) antibodies to hepatitis A virus is described. The test uses the principle of binding of IgM antibodies to anti-IgM-coated microtiter plates to determine whether the IgM antibodies attached have specificities for hepatitis A virus. In three patients with hepatitis type A followed up to 12 months, IgM antibodies to hepatitis A virus could be demonstrated from the onset of illness and during the following 2 to 3 months. When acute-phase sera from 48 patients with acute hepatitis were tested, IgM antibodies to hepatitis A virus could only be demonstrated in 18 patients previously classified as type A, whereas 30 patients with type B and non-A non-B hepatitis were negative. IgM antibodies to hepatitis A virus could not be demonstrated in 108 normal sera nor in 55 sera containing rheumatoid factor. These results indicate that the enzyme-linked immunosorbent assay for IgM antibodies to hepatitis A virus is useful in the serodiagnosis of acute hepatitis type A on a single serum sample taken during the acute phase of illness.  相似文献   

14.
A quantitative enzyme-linked immunosorbent assay (ELISA) for honeybee venom-specific IgG is reported. This ELISA surmounts the problem of poor reproducibility due to nonparallelism of dilution curves in previously reported ELISAs. The assay is performed in polyvinyl "U" microtiter plates in which HBV is physically adsorbed to the wells. The antigen is sequentially overlaid with human serum albumin, unknown serum diluted in 10% normal goat serum (NGS), and peroxidase-labeled anti-human IgG in NGS. o-Phenylenediamine is used a substrate. The addition of stabilizing protein (NGS) is shown to be crucial in producing parallel dilution curves in this heterogeneous antigen-antibody system. Sensitivity is at or below 1 ng/ml. Coefficient of variation (using a midrange serum) is 12.1% for triplicate wells, 15.5% for sequential dilution, and 15.0% for six entirely separate assays. The assay correlates well with other methods, notably with the Staphylococcus aureus protein A solid-phase radioimmunoassay (r = 0.976).  相似文献   

15.
An enzyme-linked immunosorbent assay was developed which allowed the measurement of rabbit immunoglobulin G antibodies directed to Salmonella minnesota Re glycolipid. Efficient adsorption of the antigen to polystyrene could only be effected provided it had been previously dialyzed against 0.2 M EDTA (pH 7.0) and subsequently treated with 0.2% sodium deoxycholate (15 min at 56 degrees C) in 0.05 M diethanolamine buffer (pH 9.6). The method is by far more sensitive than quantitative precipitation in the determination of IgG antibodies. Inhibition by glycolipid of binding S. minnesota Re antibodies to immobilized glycolipid attests to the specificity of the assay and permits the detection of as little as 100 ng of glycolipid.  相似文献   

16.
In contrast to the usual indirect enzyme-linked immunosorbent assay (ELISA) method for detection of antibody responses, a modified direct ELISA technique was used to measure immunoglobulin G (IgG) and IgM responses to pneumococcal capsular types 1, 3, 9N, and 23F in humans. Individual capsular polysaccharides were covalently bound to poly-L-lysine before adsorption to the solid phase. The coupling reaction was enhanced by maintenance of a constant pH of 8.2 after the addition of all reactants. The evaluation of four diluents (phosphate-buffered saline [PBS]-Tween; PBS-Tween plus 10% fetal calf serum; PBS-Tween plus 10% bovine serum albumin; and PBS-Tween plus 20% normal goat serum) showed that the sensitivity and specificity of the assay was increased with normal goat serum (10-fold). Serum samples from 10 subjects immunized with polyvalent pneumococcal vaccine were tested by direct ELISA and by radioimmunoassay. At 4 weeks postimmunization, the ELISA method showed that IgG was the predominant antibody and that IgM responses were lower or had diminished. Isotype shifts during this period would have been undetected by the radioimmunoassay method. The changes in antibody response measured by ELISA were comparable to the radioimmunoassay results. The direct ELISA method for the detection of antipneumococcal capsular antibody has been found to be a sensitive and reproducible assay for the detection of IgG and IgM antibodies.  相似文献   

17.
An enzyme-linked immunosorbent assay (ELISA) was developed for detection of antibodies to porcine parvovirus (PPV). Antisera to PPV were raised in pigs, for which PPV grown on PK15 cells was used for primary intranasal inoculations, and PPV cultured on autologous kidney cells for booster immunisations. A competition ELISA was developed, based on the principle of a double antibody sandwich assay, using immunoglobulin fractions prepared from these sera. The ELISA was compared with a haemagglutination inhibition (HI) test. The tests were equally sensitive for detecting antibodies early after infection and for detecting a significant increase in antibody titre between paired sera. A high correlation was found between antibody titres of field sera measured by the two tests (r = 0.91). We conclude that ELISA is preferable to the HI test, because it is labour-saving and can be standardised better and automated.  相似文献   

18.
The application of the rapid system of enzyme-linked immunosorbent assay (ELISA) was studied to quantify antibodies to Japanese encephalitis virus in large-scale epidemiological surveys, especially by testing under field conditions. The assay system, with 15 min for the first reaction and 30 min each for the second and the third reactions, was highly reproducible (coefficients of variation with swine positive sera were less than 5.8%) and was significantly correlated with the routine assay system with 1 h for each reaction (correlation coefficient was 0.960). Compared with the haemagglutination inhibition test, the rapid system gave a correlation coefficient of 0.916 and qualitative agreeement of 96.1%. The substitution of whole blood for serum in the first reaction was also examined not only to avoid serum separation but also to apply this system to antibody quantification in animals from which sufficient amounts of sera cannot be easily obtained: only 2 μl were needed for the test. The results obtained with 51-fold diluted whole blood had a linear relationship to those obtained with 100-fold diluted sera in swine and humans.  相似文献   

19.
Junin virus is the etiological agent of Argentine hemorrhagic fever, a serious rodent-borne disease. An enzyme-linked immunosorbent assay (ELISA) to detect Junin virus IgG antibodies in rodents was evaluated using sera from 27 Calomys musculinus and five Calomys laucha, inoculated experimentally with a live attenuated strain of this arenavirus. The test performance was compared against an indirect immunofluorescence assay (IFA). The ELISA had a sensitivity and specificity of 100% and a reproducibility of 87.9% for samples with titers above the selected cut-off value. IFA had lower sensitivity (53%) with the same specificity. The ELISA results were similar, whether carried out on whole blood or serum samples, thus eliminating the need for serum separation. A high correlation (K=0.86) between ELISA and IFA results was obtained from 1011 wild sigmodontine and murine rodents collected within and outside of the Argentine hemorrhagic fever endemic area. These results indicate that Junin virus IgG ELISA is the most suitable assay for detection of Junin virus antibodies in rodent samples.  相似文献   

20.
An enzyme-linked immunosorbent assay (ELISA) and a rapid immunochromatographic test for detection of immunoglobulin G (IgG) antibodies in severe acute respiratory syndrome (SARS) patients were developed by utilizing the well-characterized recombinant proteins Gst-N and Gst-U274. The ELISA detected IgG antibodies to SARS-CoV in all 74 convalescent-phase samples from SARS patients while weakly cross-reacting to only 1 of the 210 control sera from healthy donors. This finding thus led to a kit sensitivity, specificity, and accuracy of 100, 99.5, and 99.6%, respectively. The test thus provided a positive predictive value (PPV) of 98.7% and a negative predictive value (NPV) of 100%. In addition, the ELISA gave a positive delta of 5.4 and a negative delta of 3.6, indicating an excellent differentiation between positives and negatives. The same recombinant proteins were also applied to a newly developed platform for the development of a 15-min rapid test. The resulting rapid test has an excellent agreement of 99.6%, with a kappa value of 1.00, with the ELISA. Again, this rapid test was able to detect 100% of the samples tested (n = 42) while maintaining a specificity of 99.0% (n = 210). The PPV and NPV for the rapid test thus reached 95.3 and 100%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号