目前全数字化乳腺摄影(full-field digital mammography, FFDM)仍是乳腺癌早期发现、早期诊断的首选检查方法。而数字乳腺断层摄影技术能够克服常规FFDM中重叠纤维腺体组织干扰诊断这一主要局限性,增强对乳腺病变的可见性,显著提高诊断的敏感性和特异性,有效地降低了召回率。本文重点对于DBT在乳腺筛查中的优势及局限性进行综述。  相似文献   

2.
3.
Intraductal papillary neoplasms of the breast form a wide spectrum of pathological changes with benign intraductal papilloma and papillary carcinoma. They can occur anywhere within the breast ductal system. This review illustrates some characteristic appearances of breast papillary neoplasms on coronal planes reconstructed by automatic breast volume scan. Such manifestations are not uncommon in papillary neoplasms, and familiarity will enable confident diagnosis.Papillary lesions of the breast are a heterogeneous group of breast lesions, including intraductal papilloma, atypical papilloma and intraductal papillary carcinoma [1,2]. Although the management of intraductal papillomas is varied, surgical excision is generally recommended as a precaution against the risk of a subsequent carcinoma [3,4]. Recently, some studies have suggested that patients with a tumour measuring <1.5 cm and an ultrasound Breast Imaging—Reporting and Data System (BI-RADS) category of 3 or 4a can be potentially selected for vacuum-assisted biopsy, but only if the tumour does not extend into the branching ducts [5,6]. Ueng et al [2] recommended that localised papillary lesions should be excised completely with a small rim of uninvolved breast tissue without any prior needle instrumentation if and when the papillary nature can be determined by imaging. Therefore, a careful imaging evaluation is necessary because it could help to identify the papillary neoplasm nature and select the high-risk lesions for proper treatment.Ultrasound has a greater sensitivity for detecting all papillary lesions than mammography [7]. Recently, automated breast ultrasound scanners have been developed, and the ultrasound volume data set of the whole breast can be acquired in a standard manner [8]. They have already shown potential for characterisation of breast tumours [9,10]. However, these studies did not detail the ultrasound features of intraductal papillary neoplasms on automated breast ultrasound. The reconstructed coronal views are also expected to provide more information and thus help to differentiate these lesions from other focal breast abnormalities.  相似文献   

4.
127 breast scans were performed on 83 female patients using technetium-99m diphosphonate. 46 out of 48 patients with breast cancer had positive breast scans manifested by a focal increased uptake in 37 patients and a diffuse increased uptake in the remaining 9 patients. Benign breast lesions such as fibrocystic disease, fibroadenoma and fat necrosis may also concentrate the radioactive agent in a focal or a diffuse pattern. So breast scanning is a sensitive though nonspecific modality to detect malignant breast lesions and it is worthwhile performing it on all women referred for bone scan.  相似文献   

5.
6.
A 28-year-old woman with an infiltrating ductal carcinoma in the upper outer quadrant of the left breast diagnosed by excisional biopsy underwent lumpectomy, intraoperative lymphatic mapping, and sentinel node dissection. This was followed by an immediate completion axillary node dissection using a hand-held gamma probe and isosulfan blue to map the lymphatics. Preoperative breast lymphoscintigraphy showed drainage into the axilla and an apparent area of radiocolloid accumulation in the inferior hemisphere of the left breast. Because our protocol called only for removal of axillary sentinel nodes, the inferior hemisphere radiocolloid accumulation was not removed. The patient did not complete local regional therapy with breast irradiation and developed a mass in the inferior hemisphere of the left breast, which on biopsy was shown to be metastatic breast cancer in an intramammary lymph node. This case illustrates the potential value of breast lymphoscintograms to identify unusual sites of lymphatic drainage that may prove to be clinically relevant.  相似文献   

7.
Patients with pathologic processes of the breast commonly present in the Emergency Department (ED). Familiarity with the imaging and management of the most common entities is essential for the radiologist. Additionally, it is important to understand the limitations of ED imaging and management in the acute setting and to recognize when referrals to a specialty breast center are necessary. The goal of this article is to review the clinical presentations, pathophysiology, imaging, and management of emergency breast cases and common breast pathology seen in the ED.  相似文献   

8.
目的探讨早期乳腺癌保乳手术治疗的适应证及方法。方法分析我院近5年来20例保乳手术治疗的乳腺癌患者临床资料。结果保乳术后患者乳房外形均较好,两侧乳房基本对称,患者3年生存率为95%,复发率为5%。结论早期乳腺癌保乳手术治疗安全、疗效确切,全身综合治疗是保乳手术治疗成功的关键。  相似文献   

9.

Purpose

In our study we aim at the quantification of the heterogeneity for differential diagnosis of breast lesions in MRI.

Materials and methods

We tested a software tool for quantification of heterogeneity. The software tool provides a three-dimensional analysis of the whole breast lesion. The lesions were divided in regions with similar perfusion characteristics. Voxels were merged to the same region, if the perfusion parameters (wash-in, wash-out, integral, peak enhancement and time to peak) correlated to 99%. We evaluated 68 lesions from 50 patients. 31 lesions proved to be benign (45.6%) and 37 malignant (54.4%). We included small lesions which could only be detected with MRI.

Results

The analysis of heterogeneity showed significant differences (p < 0.005; AUC 0.7). Malignant lesions were more heterogeneous than benign ones. Significant differences were also found for morphologic parameters such as shape (p < 0.001) and margin (p < 0.007). The analysis of the enhancement dynamics did not prove successful in lesion discrimination.

Conclusion

Our study indicates that the region analysis for quantification of heterogeneity may be a helpful additional method to differentiate benign lesions from malignant ones.  相似文献   

10.
RATIONALE AND OBJECTIVES: To compare the mammographic appearance of recurrent breast cancer to the primary tumor in patients treated with breast conservation therapy. MATERIALS AND METHODS: The charts of women with American Joint Committee on Cancer Stage I or II breast cancer who underwent breast conservation therapy between 1977 and 2001 at our institution were reviewed. A total of 132 patients were diagnosed with local recurrence. RESULTS: The mammographic appearance of the local recurrence often varied from the appearance of the original breast cancer. This was especially true for women who had mammographically occult primary breast cancer. In these women, the recurrence was detected mammographically 76.9% of the time. CONCLUSIONS: Given the variable appearance of the local recurrence after breast conservation therapy, any suspicious finding needs to be carefully evaluated regardless of the mammographic appearance of the original tumor.  相似文献   

11.
Despite a worldwide consensus on the indication for breast conservation therapy (BCT), the proportion of patients treated with BCT in Japan was only 29.2% in 1997. Indications of BCT and opinions against increasing the number of BCT in Japan are discussed along with the concept of evidence-based medicine (EBM). It is evident that in Japan as well, 70% to 90% of patients with breast cancer can be treated with BCT. The main aim of irradiation in BCT is to reduce inbreast recurrences (IBR), and randomized controlled trials have confirmed that irradiation to the breast reduces IBR. Currently, much concern is being directed to the issue of surgical margins in partial mastectomy, i.e., the definition of positivity of margins and how to treat margin-positive cases. The role of boost irradiation to the tumor bed and irradiation to lymph node areas are also discussed.  相似文献   

12.

Objectives

We aimed to compare the recall rate (RR) and the cancer detection rate (CDR) of combined full field digital mammography and digital breast tomosynthesis (FFDM?+?DBT) to those of full field digital mammography (FFDM) alone in breast cancer survivors.

Methods

We enrolled 146 female breast cancer survivors schedule. All patients underwent FFDM and DBT in the same setting. Results of FFDM alone were compared to those of FFDM?+?DBT regarding patients' RR and CDR.Sensitivity, specificity, accuracy, positive and negative predictive values were also calculated for FFDM alone and for FFDM?+?DBT in detecting breast cancer lesions.

Results

Our results showed that FFDM?+?DBT decreased patients' RR by 3.4% and increased the CDR by 4.1%. Reduction in RR was evident in higher breast densities. FFDM mammography had 18 false negative lesions and 29 false positives. Sensitivity, specificity, accuracy, NPV and PPV in detecting breast lesions were: 84.2%, 53.1%, 64.0%, 86.7% and 48.9% for FFDM compared to 100%, 92.1%, 95.3%, 100% and 89.7% for FFDM?+?DBT.

Conclusion

Combined FFDM?+?DBT in the post breast cancer surveillance regimen has shown to reduce the patients' RR and to increase the CDR. FFDM?+?DBT had higher diagnostic accuracy than FFDM alone. FFDM?+?DBT ought to be a standard combination in the breast cancer surveillance in treated patients.  相似文献   

13.
Image-guided localized proton MR spectroscopy (MRS) of normal breasts and breast tumors (ductal and undifferentiated carcinomas) was performed using a dedicated double breast coil. In vivo 1H MR spectra from 10 normal volunteers showed signals from water and lipids only, even in breasts with small contribution of fatty breast tissue. In the spectra from 6 of the 12 examined patients, an intense signal assigned to choline compounds was detected. The signal was also detected at lower levels in the remaining patients. This study shows that in vivo 1H MRI/MRS examinations of breast tumors can be performed within an examination time of 45 to 60 minutes. Signals from breast tumor metabolites may be detected using in vivo 1H MRS.  相似文献   

14.
Impact of breast density on computer-aided detection for breast cancer   总被引:3,自引:0,他引:3  
OBJECTIVE: Our aim was to determine whether breast density affects the performance of a computer-aided detection (CAD) system for the detection of breast cancer. MATERIALS AND METHODS: Nine hundred six sequential mammographically detected breast cancers and 147 normal screening mammograms from 18 facilities were classified by mammographic density. BI-RADS 1 and 2 density cases were classified as nondense breasts; BI-RADS 3 and 4 density cases were classified as dense breasts. Cancers were classified as either masses or microcalcifications. All mammograms from the cancer and normal cases were evaluated by the CAD system. The sensitivity and false-positive rates from CAD in dense and nondense breasts were evaluated and compared. RESULTS: Overall, 809 (89%) of 906 cancer cases were detected by CAD; 455/505 (90%) cancers in nondense breasts and 354/401 (88%) cancers in dense breasts were detected. CAD sensitivity was not affected by breast density (p=0.38). Across both breast density categories, 280/296 (95%) microcalcification cases and 529/610 (87%) mass cases were detected. One hundred fourteen (93%) of the 122 microcalcifications in nondense breasts and 166 (95%) of 174 microcalcifications in dense breasts were detected, showing that CAD sensitivity to microcalcifications is not dependent on breast density (p=0.46). Three hundred forty-one (89%) of 383 masses in nondense breasts, and 188 (83%) of 227 masses in dense breasts were detected-that is, CAD sensitivity to masses is affected by breast density (p=0.03). There were more false-positive marks on dense versus nondense mammograms (p=0.04). CONCLUSION: Breast density does not impact overall CAD detection of breast cancer. There is no statistically significant difference in breast cancer detection in dense and nondense breasts. However, the detection of breast cancer manifesting as masses is impacted by breast density. The false-positive rate is lower in nondense versus dense breasts. CAD may be particularly advantageous in patients with dense breasts, in which mammography is most challenging.  相似文献   

15.
16.
Digital breast tomosynthesis (DBT) is a new modality that assists in detection of breast cancer. However, benign masses are also detected more easily by DBT and may require further workup. This article reviews typical imaging features of non-calcified benign masses on DBT. We also discuss the management of these benign masses. Knowledge of the imaging features of benign masses on DBT is required to minimize unnecessary callbacks.  相似文献   

17.
Nodular fasciitis of the breast simulating breast cancer on imaging   总被引:2,自引:0,他引:2  
Nodular fasciitis is a rare benign soft tissue tumour of the breast that clinically and radiologically can mimic invasive duct carcinoma. The clinical, radiological and pathological findings of nodular fasciitis of the breast in a 38-year-old woman, who presented with a palpable lesion in the upper inner aspect of the left breast, are described. The tumour is characterized histologically by a stellate spindle cell tumour with a focal myxoid background containing scattered inflammatory cells and microhaemorrhages. Pathological assessment of the lesion is essential in making the diagnosis.  相似文献   

18.
目的 分析单侧乳腺癌放疗所致健侧乳腺的剂量,并估算放疗诱发健侧乳腺癌的风险。方法 在同一医院调查49例接受单侧乳腺放疗患者的基本情况,从治疗计划系统上获取其健侧乳腺的辐射剂量并进行统计分析;利用美国电离辐射生物效应委员会报告Ⅶ第2部分(BEIR Ⅶ phase 2)推荐的风险模型,结合我国人口寿命表,预测不同年龄段单侧乳腺癌患者接受放疗诱发健侧乳腺癌的风险。结果 患者的处方剂量均为50 Gy,健侧乳腺的平均剂量为(1.21±0.89)Gy (0.14~3.59 Gy),最大点剂量平均为(17.42±13.20)Gy (0.98~45.27 Gy);健侧乳腺的最大点剂量和平均剂量变化幅度大,且有显著相关性(R=0.527,P=0.000),不同年龄段患者的健侧乳腺平均剂量差异无统计学意义(P>0.05)。基于健侧乳腺的平均剂量,估算出受照年龄为35、40、50、60、70和80岁患者的健侧乳腺癌终生归因风险分别为2 449/10万人、1 857/10万人、994/10万人、446/10万人、173/10万人和55/10万人。结论 患者接受单侧乳腺癌放疗过程中,其健侧乳腺剂量可达1 Gy水平,可能增加健侧乳腺癌发生风险对年轻患者不容忽视,在制定放射治疗计划时应尽可能控制对患者健侧乳腺的照射。  相似文献   

19.
20.
PurposeTo evaluate the impact of double reading automated breast ultrasound (ABUS) when added to full field digital mammography (FFDM) or digital breast tomosynthesis (DBT) for breast cancer screening.MethodsFrom April 2014 to June 2015, 124 women with dense breasts and intermediate to high breast cancer risk were recruited for screening with FFDM, DBT, and ABUS. Readers used FFDM and DBT in clinical practice and received ABUS training prior to study initiation. FFDM or DBT were first interpreted alone by two independent readers and then with ABUS. All recalled women underwent diagnostic workup with at least one year of follow-up. Recall rates were compared using the sign test; differences in outcomes were evaluated using Fisher's exact test.ResultsOf 121 women with complete follow-up, all had family (35.5%) or personal (20.7%) history of breast cancer, or both (43.8%). Twenty-four women (19.8%) were recalled by at least one modality. Recalls increased from 5.0% to 13.2% (p = 0.002) when ABUS was added to FFDM and from 3.3% to 10.7% (p = 0.004) when ABUS was added to DBT. Findings recalled by both readers were more likely to result in a recommendation for short term follow-up imaging or tissue biopsy compared to findings recalled by only one reader (100% vs. 42.1%, p = 0.041). The cancer detection rate was 8.3 per 1000 screens (1/121); mode of detection: FFDM and DBT.ConclusionsAdding ABUS significantly increased the recall rate of both FFDM and DBT screening. Double reading of ABUS during early phase adoption may reduce false positive recalls.  相似文献   