首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Increased awareness of benefits of early detection of breast cancer has resulted in increased numbers of screening mammographies and breast biopsies for nonpalpable lesions. Tertiary hospital studies have demonstrated positive biopsy rates from abnormal mammographic findings at 18 to 32 per cent. We examined the effectiveness of needle biopsy for nonpalpable radiographic abnormalities in our community hospital. We reviewed 167 records of patients biopsied over a 2-year period. Mammographic assessment, biopsy, and pathological assessment were performed using accepted methods. Malignancy was detected in 34 of 167 biopsies (20%). The biopsy yield rate was highest for mammographic findings of spiculated or stellate masses (75%, P < 0.01). Most biopsies (83%) were performed because of mammographic findings of microcalcifications or circumscribed enlarging masses/nodular developing densities for a positive biopsy yield rate of 16 per cent. Rates were higher in patients with personal (44%) or family history (30%) of breast cancer and in postmenopausal women (30%). These results demonstrate that 1) factors such as age, personal or family history of breast cancer, and certain mammographic features of breast lesions are associated with high biopsy yield rates, and 2) the biopsy yield rate in our community setting is comparable to tertiary hospital experience.  相似文献   

2.
Clinical and mammographic features of membranous fat necrosis (MFN) may simulate breast malignancy and tissue sampling is essential for accurate diagnosis. The aim of our study was to evaluate the clinical and imaging findings in these patients. Retrospective review of the records of breast biopsies (n = 1200) during the 5-year period 1998 to 2002 revealed eight (0.67%) cases of histologically proven MFN. Seven of the eight patients had a history of breast trauma or surgery. Seven patients underwent mammography: normal in two, a mass with curvilinear calcifications in one, and heterogeneous calcifications in four. Four patients underwent surgical excision of a palpable mass, one patient had complete excision of calcifications with large core biopsy technique, and three patients had stereotactic vacuum-assisted mammotome biopsy (VAMB). MFN should be included in the differential diagnosis of lesions in a breast with previous trauma or surgery. A minimally invasive diagnostic procedure should be considered in order to avoid excessive excisional surgery.  相似文献   

3.
Atypical lobular hyperplasia (ALH) is occasionally found in specimens obtained by percutaneous stereotactic vacuum-assisted breast biopsy for microcalcifications. Since malignancy is often found at surgical excision when atypical ductal hyperplasia is found at percutaneous biopsy, we reviewed our pathologic findings from surgery for ALH at percutaneous biopsy. This was a retrospective review of all percutaneous breast biopsy specimens for mammographic microcalcifications obtained from a single institution over a 30-month period. The pathologic findings from percutaneous biopsy were correlated with the radiologic appearance and the pathology from surgical excision. ALH was found in 13 of 766 (1.7%) stereotactic vacuum-assisted core needle biopsies performed for mammographic microcalcifications. Subsequent surgery in six patients revealed ductal carcinoma in situ (DCIS) in two patients and one case of invasive ductal carcinoma. Surgical excision is indicated for areas with ALH discovered by percutaneous biopsy for mammographic microcalcifications.  相似文献   

4.
BACKGROUND: Stereotactic breast biopsy of non-palpable lesions using the vacuum-assisted core needle biopsy (CNB) device and the large core excision biopsy system is a reliable biopsy method when compared with open biopsy. Its use in Western countries is well accepted. This study aimed to assess the feasibility and results of using these systems to perform stereotactic biopsy in Asian women. METHODS: A total of 114 patients with non-palpable mammographic lesions underwent stereotactic breast biopsy using the vacuum-assisted CNB device and the large core excision biopsy system between November 1999 and December 2002. The indications for biopsy were mammographic abnormalities considered indeterminate or suspicious that were not palpable or visible on ultrasound. The methods adopted for biopsy in Asian women were reviewed and the results including the final pathology, complications, scarring and acceptance by patients were recorded. RESULTS: Stereotactic breast biopsy was performed using the vacuum-assisted CNB device in 107 patients and the large core excision biopsy system in seven patients. Of those who underwent biopsy using the vacuum-assisted CNB device, 15 (14%) had moderate to severe bleeding during the procedure and seven (6.5%) had severe bruising afterwards. Carcinoma was detected in 31 of the 114 patients (27.2%). CONCLUSION: Although Asian women in general have smaller and denser breasts than their Western counterparts, stereotactic breast biopsy using the vacuum-assisted CNB device and the large core excision biopsy system was feasible with modification of the individual steps during the procedure. Our results are comparable with those published previously and the procedure was well accepted by patients.  相似文献   

5.
BACKGROUND: Nonpalpable mammographic abnormalities are frequently evaluated by means of a stereotactic core needle biopsy. This technique is a very sensitive indicator of invasive cancer, but is less reliable to discriminate between ductal carcinoma in situ and atypical ductal hyperplasia (ADH). The objective of this study was to determine the correlation of the 11-gauge vacuum-assisted core needle biopsy to open biopsy when a diagnosis of ADH is obtained. HYPOTHESIS: The use of 11-gauge vacuum-assisted stereotactic core needle biopsy does not conclusively diagnose ADH. DESIGN: Retrospective analysis. SETTING: University-affiliated teaching hospital. PATIENTS: Mammographic findings were evaluated with an 11-gauge vacuum-assisted stereotactic core biopsy in 1750 patients. Seventy-seven patients were diagnosed as having ADH; of these, 65 underwent excisional biopsy. MAIN OUTCOME MEASURES: Pathological upstaging rate. RESULTS: Of the 65 patients who underwent excisional breast biopsy, 11 (17%) had their condition upstaged to a breast cancer diagnosis. These patients had presented at a later age than those who retained a benign diagnosis after excisional biopsy. The number of cores taken did not correlate with diagnostic accuracy. CONCLUSIONS: Of the 65 patients who underwent open biopsy for ADH in this series, only 83% had an accurate diagnosis. A diagnosis of ADH by stereotactic core needle biopsy should be followed by an open excisional biopsy.  相似文献   

6.
The changing mammogram. A primary indication for needle localization biopsy   总被引:3,自引:0,他引:3  
Screening mammography results in improved detection and survival for women with breast cancer. Interval mammographic changes may be one of the major indications for biopsy. Four hundred fifty-two needle localization biopsies carried out for microcalcifications, mass, asymmetric density, or a combination of calcifications with mass or asymmetric density detected 95 cancers (21%). Interval mammographic changes detected 35 cases (17.9%). Invasive cancers constituted 51% of the initial group but only 34% of the cancers detected because of interval change. Benign breast disease occurred in 160 of 195 women who had undergone biopsy because of interval changes. These changes continued into the postmenopausal period. Hyperplasia and/or atypia was found in 57 (35%) of 160 of the interval group. Interval mammographic abnormalities detect significant pathologic changes in the breast and should be considered a major indication for breast biopsy.  相似文献   

7.
Rao A  Parker S  Ratzer E  Stephens J  Fenoglio M 《American journal of surgery》2002,184(6):534-7; discussion 537
BACKGROUND: Small nonpalpable mammographic abnormalities are frequently diagnosed by percutaneous stereotactically guided core needle biopsy. The reliability of the histologic diagnosis of atypical ductal hyperplasia (ADH) made from tissue obtained by 11-gauge directional, vacuum-assisted biopsy of these nonpalpable breast lesions is unknown. METHODS: The records of 31 patients who were found to have ADH by 11-gauge directional vacuum-assisted biopsy were reviewed. All of these patients subsequently underwent surgical excision with needle localization biopsy of the ADH and they are the subjects of this retrospective study. RESULTS: Eleven of the 31 patients with ADH on 11-gauge directional vacuum-assisted biopsy were upgraded to ductal carcinoma in situ or infiltrating carcinoma by the excisional biopsy. This was a 35% underestimation of malignancy in our patients. CONCLUSIONS: When the histologic diagnosis of ADH is made from tissue harvested by an 11-gauge directional vacuum assisted biopsy, surgical excision of the entire abnormality is recommended to avoid underdiagnosis of breast cancer.  相似文献   

8.
ObjectivesTo audit the outcomes of patients with non-pleomorphic lobular in situ neoplasia (LISN) of the breast and clarify the role of vacuum-assisted biopsy (VAB), surgical biopsy and conservative management for this condition.Materials and methodA single-centre retrospective review of hospital databases covering a 14-year period was performed. Patients with LISN as the most pertinent diagnosis on core needle biopsy (CNB), vacuum-assisted biopsy (VABs) or surgical biopsy were identified. The radiological features, histopathological findings and outcome of subsequent annual mammography were recorded.ResultsBetween 1998 and 2012 there were 70 patients with LISN as the most pertinent diagnosis at CNB, VAB or surgery. 52 underwent VAB, typically 18 11-gauge samples. The pathology was upgraded from the preceding 14-gauge CNB in 7 cases. Of 11 patients who underwent surgery after VAB, one (who had undergone a low tissue yield VAB) was upgraded. There were no new breast cancers during a mean annual mammographic follow-up period of 53 months in 40 patients who had VAB with complete radiological-histopathological concordance.ConclusionProvided there is adequate tissue sampling and radiological-pathological concordance, VAB is a safe alternative to open biopsy in the management of non-pleomorphic LISN.  相似文献   

9.
The incidence of malignancy in excision biopsies performed for atypical ductal hyperplasia (ADH) diagnosed on needle biopsies has decreased since the advent of larger tissue sampling and improved accuracy using vacuum-assisted Mammotome biopsy. We undertook a retrospective study to identify predictive factors for understaging of ADH diagnosed on 11-gauge Mammotome biopsy, to determine whether it was possible to avoid surgical excision in women where mammographically visible calcifications had been completely removed. Sixty-one biopsy diagnosed ADH lesions were correlated with surgical excision findings that revealed DCIS in 14 (23%). The mammographic and biopsy features were statistically analyzed using Fisher's exact test. There was no association between morphology, extent of calcifications, number of cores sampled with underestimation of malignancy (P=0.503, 0.709, 0.551 respectively). In the absence of residual calcifications, the frequency of underestimation of carcinoma still occurred in 17%.  相似文献   

10.
The evaluation of mammographic abnormalities has become a substantial effort for surgeons and radiologists. The vacuum-assisted core biopsy (VACB) has been touted as a more accurate tool for the evaluation of mammographic lesions. Diagnosis of atypical ductal hyperplasia (ADH) from a percutaneous needle biopsy of the breast is associated with a significant risk of missing a significant breast lesion. We compared 2 methods of sampling with stereotactic-guided breast biopsy, 14-gauge automated gun core biopsy (AGCB) and VACB, on the accuracy of diagnosis of ADH at a single institution. All cases of ADH, without associated malignancy, found via image-guided breast biopsy of nonpalpable lesions between March 1996 and April 2002 were evaluated. VACB biopsy needles were utilized between July 1998 to April 2002 (686 patients) and 14-gauge AGCB from March 1996 to June 1998 (350 patients). The results of these biopsies were reviewed and compared to surgical biopsy and pathological records. ADH alone was found in 53 cases (5.1% of biopsies; mean age 57.9 years). Of these, 39 patients with ADH subsequently underwent wire-localized excisional biopsy. The other 14 patients were observed. VACB biopsy understaged 7 of 29 (24%) patients with ADH (all of which were DCIS), AGCB understaged 4 of 10 cases (40%) with one being invasive. Of the patients in the core biopsy group who were initially followed, 2 developed significant lesions within 3 years of follow-up in the same quadrant of the breast. If these cases are added to the AGCB group, then 50 per cent were understaged and significantly more invasive lesions were understaged than with VACB (17% vs. 0%; P = 0.018). The VACB resulted in less understaging of ADH than AGCB. However, there remains a significant risk of missing DCIS in this setting even with the VACB. Furthermore, the risk of understaging an invasive lesion is significantly lower in this setting with a VACB than an AGCB. Although the risk of understaging ADH is lower with the VACB, we continue to recommend excisional biopsy in a good-risk patient when a diagnosis of ADH is rendered via VACB biopsy.  相似文献   

11.
O Hasselgren  R P Hummel  M A Fieler 《Surgery》1991,110(4):623-7; discussion 627-8
The purpose of this study was to determine the influence of mammographic feature and patient age on the rate of malignancy in nonpalpable breast lesions. During a 3-year period, 305 patients underwent biopsy after needle localization of 350 nonpalpable breast lesions. A total of 66 malignant breast tumors were found (biopsy yield rate, 19%): 23 carcinoma in situ, 43 infiltrating cancer. The biopsy yield rate in women younger than 50 years was 8% (12 of 153) and in women 50 years or older 27% (54 of 197; p less than 0.001). The biopsy yield rate varied with the mammographic feature in both groups of patients and was highest for spicular masses (61%), followed by strongly suspicious calcifications (29%). No cancers were found among well-defined masses or asymmetric densities. Other factors that were associated with high biopsy yield rate were personal or family history of breast cancer and diagnostic, rather than screening, mammography. The results suggest that the rate of malignancy in nonpalpable breast lesions is influenced by several factors, including age of patient and mammographic feature of the lesion. By taking all these factors into account, biopsies can possibly be performed more selectively thereby increasing the cost effectiveness of biopsy for occult breast cancer.  相似文献   

12.
HYPOTHESIS: The histopathologic correlation between stereotactic core needle biopsy and subsequent surgical excision of mammographically detected nonpalpable breast abnormalities is improved with a larger-core (11-gauge) device. DESIGN: Retrospective medical record and histopathologic review. SETTING: University-based academic practice setting. PATIENTS: Two hundred one patients who underwent surgical excision of mammographic abnormalities that had undergone biopsy with an 11-gauge vacuum-assisted stereotactic core biopsy device. MAIN OUTCOME MEASURE: Correlation between stereotactic biopsy histologic results and the histologic results of subsequent surgical specimens. RESULTS: Results of stereotactic biopsy performed on 851 patients revealed atypical hyperplasia in 46 lesions, ductal carcinoma in situ (DCIS) in 89 lesions, and invasive cancer in 73 mammographic abnormalities. Subsequent surgical excision of the 46 atypical lesions revealed 2 cases of DCIS (4.3%) and 4 cases of invasive carcinoma (8.7%). Lesions diagnosed as DCIS on stereotactic biopsy proved to be invasive carcinoma in 10 (11.2%) of 89 patients on subsequent excision. Stereotactic biopsy completely removed 21 (23.6%) of 89 DCIS lesions and 20 (27.4%) of 73 invasive carcinomas. CONCLUSIONS: In summary, 11-gauge vacuum-assisted core breast biopsy accurately predicts the degree of disease in the majority of malignant lesions; however, understaging still occurs in 11% to 13% of lesions showing atypical hyperplasia or DCIS.  相似文献   

13.
Review of 125 SiteSelect stereotactic large-core breast biopsy procedures   总被引:1,自引:0,他引:1  
Advances in stereotactic breast biopsies have introduced a variety of devices that yield different sizes of tissue samples. The choice of biopsy device should be based on which technique is most likely to yield a definitive diagnosis at the time of the initial biopsy. This is a prospective study of 104 patients who underwent a total of 125 stereotactic breast biopsies using the SiteSelect large-core biopsy device. From May 1999 to June 2001, 104 patients underwent 125 stereotactic breast biopsies with the SiteSelect large-core biopsy device. One hundred four 15 mm SiteSelect biopsies, eighteen 10 mm SiteSelect biopsies, and three 22 mm SiteSelect biopsies were performed. Atypical ductal hyperplasia (ADH) and ductal carcinoma in situ (DCIS) were found in 15% of the biopsies and infiltrating cancer was found in another 15% of the biopsies. Seventy-eight percent of the ADH and 90% of the DCIS lesions were associated with indeterminate calcifications noted on mammogram. Two of the 22 mm SiteSelect excisions yielded a specimen that contained the entire cancer with clear surgical margins. All of the patients with DCIS or invasive carcinoma underwent definitive surgical and adjuvant therapy. The sensitivity and specificity of SiteSelect in this series of patients was 100%. The SiteSelect biopsy procedure is safe, well tolerated by patients, and can be performed under local anesthesia. SiteSelect is comparable to an open excisional biopsy in its ability to obtain adequate tissue for accurate diagnosis, but excises significantly less normal surrounding breast tissue. Based on the data, indications for primary use of SiteSelect are indeterminate calcifications on mammogram, rebiopsy of a vacuum-assisted biopsy site that yielded atypia on pathologic examination, and complete excision of a lesion suspicious for invasive carcinoma in order to assess actual size and margin status.  相似文献   

14.
The aim of study was to evaluate the frequency of nonproliferative epithelial alteration and expression of Ki67 and estrogen receptors (ER) in patients using tamoxifen. Forty-four women were selected who had been taking 20mg of tamoxifen daily for at least 12 months for adjuvant treatment of breast cancer. The women underwent core biopsy in the contralateral breast into an area of highest fibroglandular mammographic density. Fragments were analyzed by immunohistochemistry for monoclonal antibody Ki67 and ER, and histopathologic analysis. It was verified that 82% of the patients presented nonproliferative epithelial alteration, 70% were ER-negative, and all had low Ki67 expression. There was no association between duration of tamoxifen therapy, patient age, mammographic density, and presence of nonproliferative alteration (P>0.05). In conclusion, tamoxifen for more than a year showed a high frequency of nonproliferative epithelial alteration and low expression of Ki67 and ER in the normal breast tissue, consistent with low cell proliferation.  相似文献   

15.
OBJECTIVE: Preoperative core biopsy in breast cancer is becoming the standard of care. The aim of this study was to analyze the various methods of core biopsy with respect to diagnostic accuracy and to examine the management and outcome of those patients with false-negative biopsies. METHODS: All patients undergoing core biopsy for breast abnormalities over a 5-year period (1999-2003) were reviewed. The accuracy rates for each method of core biopsy, the histologic agreement between the core pathology and subsequent excision pathology, and the length of follow-up for cases of benign disease were studied. Patients whose biopsies were benign but who were subsequently diagnosed with cancer underwent detailed review. RESULTS: There were 2427 core biopsies performed over the 5-year period, resulting in a final diagnosis of cancer in 1384 patients, benign disease in 954 patients, and atypical disease in 89 patients. Biopsy type consisted of 1279 ultrasound-guided cores, 739 clinically guided cores, and 409 stereotactic-guided cores. The overall false-negative rate was 6.1%, with specific rates for ultrasound-, clinical-, and stereotactic-guided cores of 1.7%, 13%, and 8.9%, respectively. False-negative biopsies occurred in 85 patients, and in 8 of these patients the diagnosis was delayed by greater than 2 months. In all other false-negative cases, "triple assessment" review allowed prompt recognition of discordant biopsy results and further evaluation. CONCLUSION: Ultrasound guidance should be used to perform core biopsies in evaluating all breast abnormalities visible on ultrasound. Adherence to principles of triple assessment following biopsy allows for early recognition of the majority of false-negative cases.  相似文献   

16.
H J Kaufman  L E Witherspoon  J L Gwin  M S Greer  R P Burns 《The American surgeon》2001,67(6):572-5; discussion 575-6
Stereotactic core needle biopsy (SCNB) is a sensitive and specific indicator of breast pathology. Commonly the first biopsy core is taken from the center of the lesion in question. Multiple cores are then taken from points peripheral to the central core. The sensitivity and specificity of the central core to diagnose breast disease is unclear. We compared the pathology of the central core biopsy with that of the remaining cores in a prospective study to determine the sensitivity and specificity of the central core to diagnose breast disease. All patients undergoing SCNB for breast lesions in a single surgical office during a 7-month period were eligible for inclusion. One hundred thirty-three patients with first cores from 145 biopsy sites were included. The histologic diagnosis from 117 (81%) of the first cores from these 145 biopsy sites were representative of their respective samples as a whole. Seventy-seven (53%) of the first cores were in complete agreement with the final histologic diagnosis whereas 40 (28%) had minor differences with the histologic diagnosis that had little or no clinical significance. Twenty-eight (19%) central core samples did not agree with the final pathologic diagnosis. Seven of these 28 patients each had a final diagnosis of cancer missed by the central core biopsy. The first core sample had a sensitivity for cancer detection of 79 per cent and specificity 100 per cent. SCNB remains a sensitive and specific identifier of breast pathology. When mammographic evidence of calcifications was the primary indication for SCNB (n = 75) calcification was present in the central core in 51 (68%). In these 51 patients the central core biopsy was in agreement with the final histologic diagnosis in 46 (90%) specimens. Histologic review of the first core sample alone lends no increased benefits and in fact misrepresents the pathology present in a significant number of patients. When analyzed as an independent predictor of breast pathology the first core is a more sensitive indicator than subsequent individual cores, but the most accurate predictor of pathology is examination of the entire group of core samples. This study confirms the need for acquisition of multiple cores from each lesion in question.  相似文献   

17.
There is evidence to suggest that the early diagnosis and treatment of breast cancer may be associated with a better prognosis. Technical advances such as mammography can detect nonpalpable breast lesions and changes associated with early carcinoma. With fine-wire localization under mammographic control, the surgeon can reliably remove nonpalpable lesions while sparing normal breast tissue. The authors describe the technique for fine-wire localization and removal of lesions and report their experience over 3 years with 262 women who underwent 269 biopsies for nonpalpable lesions. Four subgroups were identified: screened women who had no indication for mammography other than age, women who were referred for mammography by community physicians, a group referred to the Cancer Control Agency of British Columbia and a group referred to the agency for localization biopsy after mammography performed outside the Vancouver area had suggested a malignant lesion. The yield of cancers from biopsies was 10%, 38%, 43% and 26% respectively. The yield was significantly (p less than 0.05) lower for the screened group. Age over 60 years, previous breast cancer and mammographic technique were identified as possible predictors of a positive biopsy. The authors have found fine-wire localization biopsy a safe and reliable method of removing nonpalpable breast lesions.  相似文献   

18.
The objective of this research was to determine whether biopsy of the breast using a percutaneous intact specimen sampling device influences the underestimation rate of ductal carcinoma in situ (DCIS) compared to a vacuum-assisted core needle biopsy (VACNB) device. This study was a retrospective comparison of two series of 800 consecutive patients that underwent stereotactic biopsy of the breast for mammographic lesions presenting as microcalcifications classified by our institution as Breast Imaging Reporting and Data System (BI-RADS) 4 or 5. In the first series of patients (n = 800), a VACNB device was used; in the second series (n = 800), a vacuum-assisted percutaneous intact specimen biopsy (VAPIB) device was used. Initial diagnoses were made from the histopathologic examination of the tissue retrieved at biopsy. Lesions presenting as DCIS or atypical ductal hyperplasia (ADH) after percutaneous biopsy were then compared to the histopathologic analysis of specimens retrieved at surgical biopsy. DCIS upgrades were defined as cases in which the diagnosis of the stereotactic biopsy was DCIS and the diagnosis of the subsequent surgical excision was infiltrating ductal carcinoma (IDC). ADH upgrades were defined as cases in which the diagnosis of the stereotactic biopsy specimen was ADH and the diagnosis of the surgical excision was DCIS, lobular carcinoma in situ (LCIS), or IDC. The lesions retrieved by both biopsy techniques yielded a similar pathology distribution. Underestimation of DCIS occurred less frequently (p = 0.06) in the biopsy samples taken using the intact biopsy device (1/31, 3.2%) as compared to biopsy samples taken using the core needle biopsy device (7/36, 19.4%). No significant adverse events were reported. Breast biopsy can be performed safely and accurately using a vacuum-assisted percutaneous intact specimen sampling device. In this study, such a device trended toward fewer underestimations of DCIS at biopsy compared to the vacuum-assisted core needle sampling biopsy method.  相似文献   

19.
BACKGROUND: Core biopsy finding of atypical ductal hyperplasia (ADH) are generally followed by open biopsy to avoid underestimation of malignant disease. METHODS: Retrospective examination of 11 gauge stereotactic-guided vacuum-assisted core biopsies was made with respect to ADH diagnosis, follow-up open biopsy, and upgrade rate. Readily available clinical, mammographic, and pathologic features potentially contributory to an upgrade were studied. RESULTS: This series of 1,313 patients had 43 ADH diagnoses. Thirty-two had open follow-up. There were 4 upgrades. Mammographic indication for biopsy, age, removal of calcifications, and the percentage of ADH in the specimen were not significant in predicting an upgrade with all probabilities over 0.10, odds ratios not different than 1, and 95% bounds all encompassing 1. CONCLUSIONS: These data indicate a high upgrade rate (13%) for ADH-positive core biopsies with no definitive predictive criteria for an upgrade. Our data support follow-up excision of ADH lesions diagnosed by core biopsy.  相似文献   

20.
BACKGROUND: Breast health has become an increasingly important issue among the veteran population. Options for the evaluation of a breast mass or a suspicious mammographic finding include open surgical biopsy at the Veterans Affairs (VA) hospital or percutaneous image-guided biopsy at an affiliated academic institution. We examined the costs and trends in the use of surgical versus percutaneous image-guided biopsy procedures in this diagnostic algorithm. METHODS: A retrospective review was performed of 62 patients who presented to the VA General Surgery Clinic with a breast mass or abnormal mammogram from 2003 to 2005. The Massachusetts Utilization Multiprogramming System and the Decision Support System software packages were used to track costs of procedures, by Current Procedure Terminology code and date of service, performed at the affiliated academic institution and at the VA hospital. These data were analyzed and described using the R statistical computing environment. RESULTS: Forty-six patients were evaluated using open biopsy techniques in the VA operating room, including 8 incisional biopsies, 21 excisional biopsies, and 17 needle-localization excisional biopsies. Sixteen patients were evaluated using minimally invasive biopsies at the affiliated academic institution, including 3 ultrasound-guided cyst aspirations, 6 ultrasound-guided core biopsies/vacuum-assisted core biopsies, 10 stereotactic breast biopsies, and 1 fine-needle aspiration. The average cost to evaluate a breast mass or abnormal mammographic finding in the operating room was 4,368.00 dollars (SD, 2,586.00 dollars), with a median cost of 3,479.00 dollars. The average cost to evaluate a breast mass or mammographic abnormality using percutaneous image-guided procedures was 1,267.00 dollars (SD, 536.00 dollars), with a median of 1,239.00 dollars. From 2003 to 2005, the proportion of percutaneous biopsies increased from 13% to 48%, whereas the proportion of open biopsies decreased from 88% to 52%. CONCLUSIONS: Over a recent 3-year period, we observed a 3.8-fold increase in the use of percutaneous image-guided techniques for the evaluation of breast lesions in the VA Tennessee Valley Healthcare System. Diagnosis by percutaneous techniques allows planning for a definitive surgery if a lesion is malignant or possible avoidance of a surgical intervention if the lesion is benign. Our data show that the costs associated with open biopsy techniques exceed those associated with percutaneous biopsies. For VA hospitals with available resources, the option of image-guided percutaneous biopsy techniques is a cost-effective alternative to open surgical biopsy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号