首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Indium-111-leukocyte imaging in acute cholecystitis   总被引:1,自引:0,他引:1  
Eleven patients with suspected acute cholecystitis underwent sequential 99mTc-iminodiacetic derivative (IDA) and 111In-white blood cell (WBC) imaging to determine if 111In-WBCs accumulate within an acutely inflamed hemorrhagic gallbladder wall and, thus, could be employed as a reasonable alternative to 99mTc-IDA scintigraphy in detecting acute cholecystitis. Seven patients had surgically confirmed acute cholecystitis. Of these cases, five had a true-positive 99mTc-IDA and 111In-WBC, one an indeterminate 111In-WBC and true-positive 99mTc-IDA, and one a true-positive 111In-WBC and false-negative 99mTc-IDA scan. The remaining four patients did not have acute cholecystitis. All visualized their gallbladder within 1 hr after 99mTc-IDA administration and none had 111In-WBC gallbladder wall uptake. Both 111In-WBC and 99mTc-IDA scintigraphy accurately detected acute cholecystitis: hepatobiliary scintigraphy demonstrated a cystic duct obstruction and 111In-WBC imaging detected the inflammatory infiltrate within the gallbladder wall. The sensitivity and specificity of each was 86% and 100%, respectively.  相似文献   

2.
A series of 19 patients, who were clinically suspected of developing avascular necrosis of bone following fracture, were entered into a pilot study comparing the use of bone marrow scintigraphy with conventional skeletal scintigraphy. Two-phase bone scintigraphy, using 600 MBq of 99Tcm-HMDP, and perfusion and late-phase nanocolloid scintigraphy, using 370 MBq of 99Tcm-nanocolloid, were performed on each patient. In both methods, photon deficiency at the site of interest was taken to indicate avascularity. The perfusion phase of both methods was found to be unhelpful. Agreement between methods was obtained in 18 patients (95%). Six patients had abnormal nanocolloid scans, one of which was normal on the conventional bone scintigram. The remaining 13 patients had no evidence to suggest avascularity in either method. Three of the patients with abnormal scans have had hip replacement surgery following which avascularity of the femoral head was confirmed. 99Tcm-nanocolloid scintigraphy is thus shown to be a very sensitive method of demonstrating avascularity of bone following trauma.  相似文献   

3.
Forty-nine patients with 50 fracture nonunions 4-48 months after injury underwent technetium-99m methylene diphosphonate (99mTc-MDP) scintigraphy on day 1, combined 99mTc-MDP and indium-111 leukocyte (111In-WBC) scintigraphy on day 2, and gallium-67 (67Ga) scintigraphy on day 3. The results were compared to evaluate the relative abilities of these scintigraphic techniques to detect osteomyelitis. Nine patients had clinical evidence of infection at the time of imaging, and 40 patients (41 fractures) did not. Open-biopsy cultures were performed at all fracture sites and were positive at 21 (42%) of the 50 sites. Combined 99mTc-MDP/111In-WBC images were interpreted with the use of two criteria. A positive study by the first criterion required 111In-WBC localization in the region of the nonunion fracture. A positive study by the second criterion required 111In-WBC localization in bone at the fracture site. The first criterion yielded a sensitivity of 84%, specificity of 72%, and accuracy of 74%; the specificity improved to 97% with an accuracy of 88% when the second criterion was used. Ten (25%) of the 40 patients thought not to have osteomyelitis by clinical criteria at the time of imaging had true-positive 99mTc-MDP/111In-WBC studies by biopsy culture results. Gallium-67 studies were interpreted as nondiagnostic if localization of radioisotope at fracture sites was equal to that with 99mTc-MDP, positive if 67Ga localization was greater than that of 99mTc-MDP, and negative if it was less than that of 99mTc-MDP. Twenty-one 67Ga studies were interpreted as nondiagnostic; 11 (52%) of the 21 had culture-positive fracture sites. The accuracy of 67Ga/99mTc-MDP imaging was 39%. Combined 99mTc-MDP/111In-WBC imaging is useful in the detection of osteomyelitis at fracture nonunion sites and improves the specificity of 111In-WBC imaging by differentiating inflammation/infection in adjacent soft tissue from osteomyelitis at the fracture site. Gallium-67 with 99mTc-MDP imaging is not sufficiently reliable in this clinical setting to be useful as an indicator for osteomyelitis.  相似文献   

4.
Fifty-seven investigations of the skeletal system were performed on 54 patients, using a 99Tcm-labelled nanometer-sized HSA colloid in a crossover comparison with 111In oxine-labelled granulocytes for the detection of sites of infection. The findings were in agreement in 55 out of 57 investigations (96.5%). Based on 44 studies in which a final clinical diagnosis was obtained, both methods were found to display the same specificity (93%), whilst the sensitivity of 99Tcm nanocolloid scintigraphy (87%) was slightly higher than that obtained with 111In leucocyte scintigraphy (81%). In our opinion, 99Tcm nanocolloid is easier to use and the total duration of the investigation is considerably shorter. The use of 99Tcm is scintigraphically more advantageous and, with the dosage required, the absorbed radiation dose to the red bone marrow is three times lower than with 111In granulocytes. For the detection and therapy monitoring of osteomyelitis, as well as for the investigation of arthroplasties suspected of infective loosening, we consider scintigraphy with 99Tcm nanocolloid to be equivalent to leucocyte scintigraphy. Identical findings were obtained with both tracers in suspected spondylodiscitis.  相似文献   

5.
In 35 patients suspected of an infectious focus, the outcome of scintigraphy with 111In-labeled autologous leukocytes (WBC) and 111In-labeled human nonspecific immunoglobulin G (IgG) was evaluated in a prospective comparative study. Clinical, roentgenologic and microbiologic findings were considered to be proof of the presence of infection or inflammation. In this group of patients with mainly subacute infections, 111In-IgG scintigraphy performed significantly better than 111In-WBC scintigraphy, especially in infections of the locomotor system, but also in various soft-tissue infections. Both techniques showed disappointing results in patients with disseminated yersinia infection and in some patients with tuberculosis. Overall sensitivity and specificity was 74% and 100% for 111In-IgG scintigraphy and 52% and 78% for 111In-WBC scintigraphy, respectively.  相似文献   

6.
Fourteen patients (16 sites) with clinical and/or radiographic evidence of neuropathic osteoarthropathy (Charcot joints) were evaluated with combined indium-111-leukocyte (111In-WBC) and technetium-99m-methylene diphosphonate (99mTc-MDP) bone imaging for suspected osteomyelitis. Magnetic resonance (MR) images were obtained in seven patients. Using a positive bone culture as the criterion for the presence of osteomyelitis, there were four true-positive studies, six true-negative sites, and one false-negative 111In-WBC study. Five of 16 sites (31%) had false-positive 111In-WBC uptake at noninfected sites. There were four true-positive and three false-positive MR studies. All false-positives showed at least moderately abnormal findings by both techniques at sites of rapidly progressing osteoarthropathy of recent onset. In this preliminary study, both techniques appear to be sensitive for detection of osteomyelitis, and a negative study makes osteomyelitis unlikely. However, the findings of 111In-WBC/99mTc-MDP and MR images at sites of rapidly progressing, noninfected neuropathic osteoarthropathy may be indistinguishable from those of osteomyelitis.  相似文献   

7.
OBJECTIVES: This is a retrospective study to evaluate a 3-hour In-111-labeled leukocyte image as a surrogate for a Tc-99m nanocolloid marrow scan in the investigation of suspected orthopedic infection using In-111 leukocyte scintigraphy. METHODS: Images from 51 patients who had received contemporaneous In-111-labeled leukocyte scintigraphy and Tc-99m nanocolloid marrow scintigraphy were reviewed. Initially, the 3-hour and 22-hour In-111-labeled leukocyte images were compared. Sites of abnormal uptake on the 22-hour image were correlated with the 3-hour image and were graded according to the level of concordance or discordance. One week later, the Tc-99m nanocolloid images and 22-hour In-111-labeled leukocyte images of the same patients were compared and graded for concordance or discordance. When discrepancies in grading arose between the observers, a consensus opinion was achieved after additional review of the images a week later. RESULTS: On inspection of the 22-hour In-111 leukocyte images, 93 sites of focal, potentially abnormal leukocyte accumulation were identified. When the grading system was reduced to simply "concordant" or "discordant," there was good agreement between the observers in the majority of cases, with kappa statistics 0.77 for Tc-99m nanocolloid versus 22-hour In-111-labeled leukocyte images and 0.78 for 3-hour versus 22-hour In-111-labeled leukocyte images. Using the comparison of the Tc-99m nanocolloid marrow scan and the 22-hour In-111-labeled leukocyte images to identify concordance or discordance as the "gold standard" for scintigraphic evaluation of suspected orthopedic infection, comparison of the 3-hour In-111-labeled leukocyte images with the 3-hour In-111-labeled leukocyte images gave a sensitivity of 77%, a specificity of 77%, and an accuracy of 77%. CONCLUSIONS: A 3-hour image is helpful using In-111-labeled leukocyte scintigraphy.  相似文献   

8.
111In-granulocyte scintigraphy was performed on 245 patients in whom a localized infection was suspected. In 123 patients scintigraphy was positive and of these 35 (28%) had intestinal accumulations of 111In-granulocytes. Specific local causes for the intestinal uptake of radioactivity were antibiotic associated colitis (eight patients), local pyogenic bowel infection (four patients), systemic disease (two patients), bowel necrosis (two patients), colonic cancer (one patient) and Stevens-Johnson's syndrome (one patient). Nonspecific mechanisms of bowel accumulation were desquamation of labelled granulocytes (12 patients) and bleeding (two patients). In three cases the mechanism of colonic accumulation of granulocytes was not revealed. These results show that unexpected accumulations of labelled granulocytes in the gut is not a rare phenomenon and is often due to clinically significant intestinal inflammation or other disease, especially in patients who do not have signs of respiratory, pancreatic or oesophageal inflammation causing desquamated granulocytes to accumulate in the gut.  相似文献   

9.
Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy (111In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ form that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111In-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses.  相似文献   

10.
This study was undertaken to evaluate the use of Indium-111-labeled leukocyte (111In-WBC) imaging compared with Technetium-99m pertechnetate (99mTcO4-) imaging in 19 patients with rheumatoid arthritis (RA) and 8 with osteoarthritis. Knee and wrist joints were evaluated for both radionuclides. The results indicated a good correlation of the clinical assessment of pain and swelling with joint uptake ratio (JUR) between 111In-WBC and 99mTcO4- in RA and osteoarthritis patients. We observed a discrepancy in both imagings in "burned out" cases. It was concluded that a JUR of 111In-WBC could distinguish active RA from inactive RA or osteoarthritis at a value of 1.15 and that the use of 111In-WBC was a more reliable procedure than 99mTcO4-.  相似文献   

11.
111In-granulocyte scintigraphy was performed on 245 patients in whom a localized infection was suspected. In 123 patients scintigraphy was positive and of these 35 (28%) had intestinal accumulations of 111In-granulocytes. Specific local causes for the intestinal uptake of radioactivity were antibiotic associated colitis (eight patients), local pyogenic bowel infection (four patients), systemic disease (two patients), bowel necrosis (two patients), colonic cancer (one patient) and Stevens-Johnson's syndrome (one patient). Nonspecific mechanisms of bowel accumulation were desquamation of labelled granulocytes (12 patients) and bleeding (two patients). In three cases the mechanism of colonic accumulation of granulocytes was not revealed. These results show that unexpected accumulations of labelled granulocytes in the gut is not a rare phenomenon and is often due to clinically significant intestinal inflammation or other disease, especially in patients who do not have signs of respiratory, pancreatic or oesophageal inflammation causing desquamated granulocytes to accumulate in the gut.  相似文献   

12.
The usefulness of 99mTc-nanocolloid for the assessment of localization and disease activity of colitis in patients suffering from inflammatory bowel disease (IBD) was investigated in 10 patients. Results of 99mTc-nanocolloid scintigraphy were compared with Indium-111 autologous granulocyte scintigraphy and the activity index according to Van Hees. In none of the patients a true positive result of the 99mTc-nanocolloid scintigraphy was encountered, while 111In-granulocyte scintigraphy was positive in 7 of 10 patients with active disease. Radioactivity became visible in the small bowel starting 2 h after injection of 99mTc-nanocolloid most likely because of excretion by the liver of degradation products of the radiopharmaceutical. The authors conclude that despite a previous communication 99mTc-nanocolloid cannot replace 111In-granulocytes for the assessment of IBD patients with active colitis.  相似文献   

13.
Crohn's disease (CD) is a chronic inflammatory bowel disease that may involve the whole gut. Marked intestinal T cell and macrophage activation is a key feature of the disease. Polymorphonuclear cell infiltration is also observed in the diseased gut, mainly during active inflammation. Scintigraphic detection of granulocytes and activated lymphocytes infiltrating the gut wall may be useful in identifying a subgroup of patients with clinically inactive CD who are undergoing early clinical relapse. The aims of the present study were (a) to compare the effectiveness of scintigraphy with (99m)Tc-labelled interleukin-2 ((99m)Tc-IL2) and with (99m)Tc-HMPAO labelled granulocytes ((99m)Tc-WBC) in detecting the presence and extent of bowel inflammation in patients with long-term inactive CD (>12 months) and (b) to assess the accuracy of these techniques in predicting future disease relapse. We studied 29 patients with ileal and/or colonic CD in stable clinical remission (Crohn's Disease Activity Index <150 for at least 12 months) using both (99m)Tc-IL2 and (99m)Tc-WBC scintigraphy in order to evaluate the extent of acute and chronic inflammation in the bowel. Planar and single-photon emission tomography images were acquired in each patient at 1 h p.i. For quantitative analysis of (99m)Tc-IL2 uptake, the abdomen was divided into 32 regions of interest. Despite the absence of symptoms, 18 patients (62%) showed a positive (99m)Tc-IL2 and 18 (62%) a positive (99m)Tc-WBC scan. Only 12 patients (41.4% of the total group) were positive on both scans, and the sites of IL2 and granulocyte bowel uptake were usually located in different segments, indicating that in CD, acute and chronic inflammation can be present in different sites. As far as the prognostic role of the two scans in predicting future disease relapse is concerned, both (99m)Tc-IL2 and (99m)Tc-WBC scintigraphy showed a high negative predictive value (1.00 and 0.91, respectively) but a weak positive predictive value (0.44 and 0.39, respectively). Nevertheless, Kaplan-Meier curves generated between scintigraphic findings and time free from disease relapse were statistically different only for (99m)Tc-IL2 scintigraphy (log-rank test, P=0.013). These results indicate that (99m)Tc-IL2 scintigraphy can be useful in selecting CD patients in clinical remission who could benefit from preventive therapy to avoid disease relapse.  相似文献   

14.
Abdominal scintigraphy shows silent gut inflammation in patients with spondyloarthropathies (Sp) without clinical evidence of gut inflammation. Abdominal scintigraphy images are different than those obtained in patients with ulcerative colitis or Crohn's disease and are not related to the anti-inflammatory drugs administered. The aim of this study was to examine the clinical associations of findings on abdominal scintigraphy in patients with Sp. A total of 204 Sp patients (European Spondylarthropathy Study Group 1991 criteria) and 54 non-Sp controls receiving non-steroidal anti-inflammatory drugs were studied. Abdominal scintigraphy images were obtained at 30 and 120 min after injection of technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled leucocytes. 99mTc-HMPAO-labelled leucocyte scans were positive in 104 Sp patients (50.9%) and in six non-Sp controls (2.9%) (P<0.001; OR=8.32; 95% CI=3.23-22.67). Silent gut inflammation was not associated with any of the following: age of onset, duration of evolution, sex, family history of Sp or psoriasis, articular manifestations, extra-articular manifestations, radiological findings or HLA-B27 positivity. Positive abdominal scintigraphy was associated with active disease (P < 0.0001; OR=52.7; 95% CI=19-145.6) and an increase in the C-reactive protein (P < 0.005; OR = 3.4; 95% CI = 1.5-7.4). It is concluded that (a) abdominal scintigraphy using 99mTc-HMPAO-labelled leucocytes is of value in detecting the silent gut inflammation in Sp patients, and (b) silent gut inflammation is related to the clinical activity, but is not associated with any particular type of illness or with HLA-B27.  相似文献   

15.
Sentinel node was detected by 99mTc labeled nanocolloid in five patients with breast cancer. Surgery of breast cancer was done at 16 hours after the administration of 74 MBq of 99mTc labeled nanocolloid. Sentinel node was searched by scintigraphy prior to surgery and by gamma-probe during surgery. Radioactivity of injected site, sentinel nodes, blood contaminated gauze, and other garbage was measured by GM detector. Radiation to medical staffs was monitored by a pocket radiation detector and film batches. Sentinel nodes were successfully detected both by scintigraphy and gamma-detector. More than 70% of radioactivity remained in the administered site at 16 hours. Small amount of radioactivity was detectable in the sentinel node. Almost no radioactivity was detectable in blood-contaminated gauze and other garbage. Radiation dose to the main surgeon was 4 to 6 microSv per surgery by a pocket radiation detector. Radiation dose to the assistant surgeon was 2 microSv per surgery. Radiation dose by labeling or injection was 0 to 1 microSv per procedure. No detectable radiation was measured by film batches. It is concluded that the detection of sentinel node by 99mTc labeled nanocolloid is a safe procedure from the point of radiation safety consideration.  相似文献   

16.
Although few reports address the use of three-phase bone scanning (TPBS) and 111In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.  相似文献   

17.
A wide variety of focal and diffuse infectious processes involve the abdomen. At one extreme are diseases such as pyelonephritis, cystitis, and pelvic inflammatory disease, conditions usually diagnosed without imaging studies and treated without complications. At the other extreme are abdominal abscesses, which may defy clinical diagnosis, are associated with significant morbidity and mortality, and may remain undetected or insufficiently characterized in spite of multiple imaging studies. The limited diagnostic value of clinical evaluation and plain film radiography in abscess detection has lead to widespread use of sophisticated imaging techniques including Gallium-67 (67Ga) scintigraphy, Indium-111 WBC (111In-WBC) scintigraphy, computed tomography (CT), and ultrasonography (US). Abdominal abscesses occur in a wide variety of anatomic sites, may involve any abdominal organ system, and have a number of different causes. The heterogeneity of the disease process and the varying capabilities of the different imaging techniques (with respect to site and organ system) make reliance on a single technique undesirable. An algorithmic approach using 67Ga or 111In-WBC scintigraphy, CT, and US provides a logical and clinically practical approach to complicated abdominal infection. By recognizing differences in clinical presentation and by appreciating the diagnostic strengths and weaknesses of nuclear medicine, CT, and US, the algorithm provides a reliable and direct route to accurate diagnosis while minimizing unnecessary examinations.  相似文献   

18.
The diagnosis of brain abscess is often difficult, as the clinical symptoms are not specific. Computed tomography (CT) and magnetic resonance imaging (MRI) are highly sensitive, but different cerebral lesions, especially neoplasms, can have the same ring-like contrast enhancement. Brain abscess is a severe illness requiring rapid diagnosis to choose the most appropriate therapy. Technetium-99m hexamethylpropylene amine oxime (HMPAO)-labelled leucocyte scintigraphy is commonly used to detect an inflammatory process. The aim of this study was to present the results obtained with leucocyte scintigraphy in 65 patients with intracranial mass lesions and clinical findings compatible to or suggestive of brain abscess. The final diagnosis, based on surgery, clinical findings and stereotatic puncture, was brain abscess in 17 patients, primary brain neoplasm in 22, brain metastasis in 16, lymphoma in 2, cysticercosis in 2, hematoma in 2 and cerebral infarction in 4. 99mTc-HMPAO leucocyte scintigraphy was positive in all abscess cases. The scan was negative in the rest of the patients examined, with the exception of one lesion, which was finally diagnosed as a tumour (1 false-positive). All patients who did not have false-negative scans were treated with steroids. The sensitivity, specificity and diagnostic accuracy of leucocyte scintigraphy was 100%, 97.8% and 98.4%, respectively. In conclusion, in our experience, leucocyte scintigraphy is a valuable aid in the differential diagnosis between abscess and neoplasm.  相似文献   

19.
Forty-five patients with various inflammatory diseases were imaged with 99Tcm-HMPAO labelled leucocytes and 99Tcm-nanocolloid within 7 days. The overall sensitivity of 99Tcm-leucocytes was 97% and that of 99Tcm-nanocolloid 59% and both agents had a 100% specificity. The 99Tcm-leucocyte method showed reliable results in various inflammatory and infectious conditions, and seems suitable as a primary imaging method. On the contrary, 99Tcm-nanocolloid cannot be recommended for use in inflammatory bowel diseases, soft tissue abscesses or prosthetic vascular graft infections. However, 99Tcm-nanocolloid gave reliable information in inflammatory and infectious bone and joint diseases in which it had a 90% sensitivity and 100% specificity. In those lesions the 99Tcm-nanocolloid method may be useful, because it is simple, fast and cheap. Yet, further evaluation is needed.  相似文献   

20.
Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3-0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3-4 h postinjection (p.i.) and the late scan 18-24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of 111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号