首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The aim of this in vitro study was to assess the effect of two different adhesive application methods on shear dentin bond strength (ISO 29022) using three various adhesive systems. A mid-coronal section of 77 intact third human molars with fully developed apices was made to create flat bonding substrates. The materials used in the study were Excite F (Ivoclar Vivadent), Prime&Bond Universal (Dentsply Sirona) and G-Premio Bond (GC). The application of each adhesion system was performed in two different ways. In the first group, the bonding agent was light cured immediately after the application (conventional method), while in the second group the adhesive and composite were cured concurrently (“co-curing” method). A total of 180 specimens were prepared (3 adhesives × 2 method of application × 30 specimens per experimental group), stored at 37 °C in distilled water and fractured in shear mode after 1 week. Statistical analysis was performed using ANOVA and Weibull statistics. The highest bond strength was obtained for Prime&Bond conventional (21.7 MPa), whilst the lowest bond strength was observed when co-curing was used (particularly, Excite F 12.2 MPa). The results showed a significant difference between conventional and co-curing methods in all materials. According to reliability analysis, the co-curing method diminished bond reliability. Different application techniques exhibit different bond strengths to dentin.  相似文献   

2.
This study investigated the influence of conventional (10 s at 1160 mW/cm2) and fast high-irradiance (3 s at 2850 mW/cm2) light curing on the micro-tensile bond strength (μTBS) of bulk-fill resin composites bonded to human dentin. Sixty-four extracted human molars were ground to dentin and randomly assigned into eight groups (n = 8 per group). After application of a three-step adhesive system (Optibond FL), four different bulk-fill composites (two sculptable and two flowable composites) were placed. Of these, one sculptable (Tetric PowerFill) and one flowable (Tetric PowerFlow) composite were specifically developed for fast high-irradiance light curing. Each composite was polymerized with the conventional or the fast high-irradiance light-curing protocol. The specimens were cut into dentin-composite sticks, μTBS was determined and failure modes were analyzed. Statistical analysis was performed using t-test for independent observations and one-way ANOVA. A statistical difference between the curing protocols was only found for Tetric PowerFlow, where the conventional protocol (23.8 ± 4.2 MPa) led to significantly higher values than the fast high-irradiance light-curing protocol (18.7 ± 3.7 MPa). All other composite materials showed statistically similar values for both polymerization protocols. In conclusion, the use of fast high-irradiation light curing has no negative influence on the μTBS of the investigated high-viscosity bulk-fill composites. However, it may reduce the dentin bond strength of flowable bulk-fill composite.  相似文献   

3.
The purpose of this study was to investigate the effect of cold atmospheric plasma (CAP) treatment on resin nanoceramic (RNC) surface state and its bond strength with resin cement. RNC with different surface treatments were prepared: control, sandblasting treatment (SB), hydrofluoric acid etching (HF) and plasma treatment of helium gas (CAP-He) and argon gas (CAP-Ar). The prepared samples were measured by SEM, Ra, Rz, contact angle goniometer, and XPS for surface characteristics. The shear bond test of RNC was examined in nine groups: SB + saline coupling agent (SL), HF + SL, CAP-He/Ar, CAP-He/Ar + SL, SB + CAP-He/Ar + SL, and control. The bond strength between RNC and resin cement was compared using shear bond strength test, before and after thermocycling. After CAP irradiation, the surface topography maintained, while the surface water contact angle was significantly reduced to 10.18° ± 1.36° (CAP-He) and 7.58° ± 1.79° (CAP-Ar). The removal of carbon contamination and inducing of oxygen radicals was detected after CAP treatment. The bond strength was improved by CAP treatment, but varied on CAP gas species and combination methods. CAP of Ar gas had better SBS than He gas. After thermocycling, CAP-Ar + SL showed the maximized shear bond strength (32.38 ± 1.42 MPa), even higher than SB + SL group (30.08 ± 2.80 MPa, p < 0.05). In conclusion, CAP treatment of helium and argon can improve the bonding properties of RNC by improving surface wettability, and CAP of argon gas combined with silane coupling agent shows the highest bond strength.  相似文献   

4.
The objective of this study was to examine the effect of different conditions of simulated hydrostatic pulpal pressure on the μTBS of HEMA-based and HEMA-free dentin bonding agents (DBAs). The influence of dentin location (deep and superficial) on μTBS was also evaluated. Flat coronal dentin surfaces of extracted human molars were prepared. Three groups of resin-bonded specimens were exposed to different pulpal pressures. Pulpal pressure was maintained for 20 min for each group. A flowable resin composite was used for coronal build-up. The bonded teeth were sectioned and, after 24 h of water storage, stressed to failure using the microtensile tester (μTBS). Failed samples were analyzed by SEM inspection. HEMA-based DBAs were much more sensitive to pulpal pressure conditions than non-HEMA-containing DBAs. Pulpal pressure had a greater influence in deep dentin. The HEMA-free DBA was insensitive to the presence or absence of pulpal pressure condition. SEM inspection confirmed a relationship between the presence of voids inside the HEMA-based DBAs layer and the lower μTBS results. HEMA-based DBAs are more sensitive to pulpal pressure conditions than HEMA-free DBAs. Interestingly, HEMA-free DBA showed a greater number of water droplets at resin–dentin interface in all tested conditions.  相似文献   

5.
The aim of this study is to investigate the effect of non-thermal atmospheric pressure plasma (NTP) on retentive strength (RS) between the zirconia crown and the titanium implant abutment using self-adhesive resin cement. Surface free energy (SFE) was calculated on 24 cube-shaped zirconia blocks, and RS was measured on 120 zirconia crown-titanium abutment assemblies bonded with G-CEM LinkAce. The groups were categorized according to the zirconia surface treatment as follows: Control (no surface treatment), NTP, Si (Silane), NTP + Si, Pr (Z-Prime Plus), and NTP + Pr. Half of the RS test assemblies were aged by thermocycling for 5000 cycles at 5–55 °C. The SFE was calculated using the Owens-Wendt method, and the RS was measured using a universal testing machine at the maximum load until failure. One-way analysis of variance (ANOVA) with post-hoc Tukey honestly significant difference (HSD) was performed to evaluate the effect of surface treatments on the SFE and RS. Independent sample t-test was used to compare the RS according to thermocycling (p < 0.05). For the SFE analysis, the NTP group had a significantly higher SFE value than the Control group (p < 0.05). For the RS test, in non-thermocycling, the NTP group showed a significantly higher RS value than the Control group (p < 0.05). However, in thermocycling, there was no significant difference between the Control and NTP groups (p > 0.05). In non-thermocycling, comparing with the NTP + Si or NTP + Pr group, there was no significant difference from the Si or Pr group, respectively (p > 0.05). Conversely, in thermocycling, the NTP + Si and NTP + Pr group had significantly lower RS than the Si and Pr group, respectively (p < 0.05). These results suggest that NTP single treatment for the zirconia crown increases the initial RS but has little effect on the long-term RS. Applied with Silane or Z-Prime Plus, NTP pre-treatment has no positive effect on the RS.  相似文献   

6.
The purposes of this study were to evaluate the efficacy of water–airborne-particle abrasion (WAPA) as pre-etching procedure for tooth surfaces to increase bond strength, and to compare the survival rate of WAPA vs. non-WAPA glass–ceramic restorations with a 15-year follow-up. The occlusal surfaces of 20 human molars were sectioned and flattened. The prepared surfaces areas were subdivided into two parts: one received WAPA treatment (prophy jet handpiece with 50 µm aluminium oxide particles) followed by acid etching (37% phosphoric acid for 20 s/3-step etch-and-rinse); the other one was only acid-etched. In total, 108 specimens were obtained from the teeth, of which 80 were used to measure the micro-tensile bond strength (μTBS) in the WAPA (n = 40) and control (n = 40) groups, while the remaining specimens (n = 28) were investigated via SEM to evaluate the micromorphology and roughness (Ra) before and after the different treatment steps. The survival rate (SR) was performed on 465 glass–ceramic restorations (131 patients) comparing WAPA treatment (n = 183) versus non-WAPA treatment (n = 282). The bond strength was 63.9 ± 7.7 MPa for the WAPA group and 51.7 ± 10.8 MPa for the control group (p < 0.001). The Ra was 98 ± 24 µm for the enamel control group, 150 ± 35 µm for the enamel WAPA group, 102 ± 27 µm for the dentin control group and 160 ± 25 µm for the dentin WAPA group. The Ra increase from the WAPA procedure for enamel and dentin was statistically significant (p < 0.05). Under SEM, resin tags were present in both groups although in the WAPA they appeared to be extended in a 3D arrangement. The SR of the WAPA group (11.4 years) was 94%, while the SR of the non-WAPA group (12.3 years) was 87.6% (p < 0.05). The WAPA treatment using aluminium oxide particles followed by a 3-step etch-and-rinse adhesive system significantly improved bioadhesion with an increased bond strength of 23.6% and provided superior long-term clinical performance of glass–ceramic restorations.  相似文献   

7.
The bond strength between ultra-high-performance concrete (UHPC) and normal-strength concrete (NC) plays an important role in governing the composite specimens’ overall behaviors. Unfortunately, there are still no widely accepted formulas targeting UHPC–NC interfacial strength, either in their specifications or in research papers. To this end, this study constructs an experimental database, consisting of 563 and 338 specimens for splitting and slant shear tests, respectively. Moreover, an additional 35 specimens for “improved” slant shear tests were performed, which could circumvent concrete crushing and trigger interfacial debonding. Additionally, for the first time in our tests, the effect of casting sequence on UHPC–NC bond strength was identified. Based on the database, an artificial neural network (ANN) model is proposed with the following inputs: namely, the normal stress perpendicular to the interface, the interface roughness, and the compressive strengths of the UHPC and NC materials. Based on the ANN analyses, the explicit expression of UHPC–NC bond strength is proposed, which significantly lowers the prediction error. To be fully compatible with the specifications, the conventional shear-friction formula is modified. By splitting the total force into adhesion and friction forces, the modified formula additionally takes the casting sequence into account. Although sacrificing accuracy to some extent compared to the ANN model, the modified formula relies on a solid physical basis and its accuracy is enhanced significantly compared to the existing formulas in specifications or research papers.  相似文献   

8.
The purpose of this study was to investigate the influence of different surface treatment methods on the micro-tensile bond strength (μTBS) of resin-matrix ceramic (RMC) blocks repaired with resin composite. Three different prefabricated RMC blocks including Lava Ultimate (LU), Grandio Blocs (GB), and Shofu Block HC (HC) were thermo-cycled and divided into five surface treatment groups: Control (C), bur grinding (G), airborne particle abrasion (APA), Er,Cr:YSGG laser irritation (LI), and APA combined with LI (APA+LI). After surface treatments, topographic alterations were examined by scanning electron microscopy. Then, Universal Adhesive (Single Bond Universal) was applied and repair was simulated with nanohybrid composite (Grandio SO). Bonded specimens were cut into 1 mm2 sized beams (n = 16) and a μTBS test was conducted by using a universal test machine. Fracture types were evaluated by using a stereomicroscope. The bond- strength data was evaluated by two-way ANOVA and Tukey post-hoc test (α = 0.05). The μTBS values were significantly affected by the surface treatment variable and the interaction terms of the variables (p ≤ 0.001). However, no significant effect of RMC type was detected (p > 0.05). Among all materials, GBAPA+LI indicated the highest µTBS value. Except for the GBC, all surface treatments showed clinically acceptable bond-strength values. However, the surface treatments applied to GB and LU before the repair processes increased the repair bond-strength values while causing a negative effect for HC. In addition, LI and APA+LI can be applied as an alternative route compared to other procedures recommended by the manufacturer for surface preparation in intraoral RMC repair.  相似文献   

9.
The aim of this study was to evaluate the effect of different cleaning methods on the shear bond strength (SBS) of resin cement to contaminated zirconia specimens. Eighty rectangular-shaped specimens (2 × 5 × 10 mm) were fabricated from Zirconia blocks (IPS e.max ZirCAD) and randomly divided into 8 groups (n = 10). Group A (control) was not exposed to contaminants. The following tests specimens were contaminated with saliva and silicone indicating paste. Group B was coated with ceramic primer, then subjected to contamination. Groups C, D, E, F, G, and H were contaminated; cleaned with water rinse, Ivoclean, air particle abrasion, hydrofluoric acid, KATANATM Cleaner and ZirCleanTM, respectively, and then coated with ceramic primer and bonded to dual cure resin cement cylinders. All the specimens were subjected to artificial aging and surviving specimens were subjected to the SBS test. For statistical analysis, ANOVA and multiple comparison methods at the 0.05 significance level were used. There was no statistically significant difference among Ivoclean (21.48 ± 2.90 MPa), air particle abrasion (21.92 ± 2.85 MPa), and the control group (24.68 ± 5.46). The application of ceramic primer before contamination did not preserve the SBS of resin cement to zirconia. Cleaning the contaminated zirconia surface with hydrofluoric acid (15.03 ± 3.63) or KATANATM Cleaner (17.27 ± 7.63) did not restore SBS to the uncontaminated state, but it was significantly higher than simply rinsing with water (12.46 ± 5.17) or the use of ZirCleanTM (11.59 ± 5.53). The bond strength of resin cement to zirconia was influenced by cleaning methods.  相似文献   

10.
This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (μSBS) of luting agents to CAD–CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD–CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers’ recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the μSBS test. Data were analyzed using two-way ANOVA and Bonferroni’s post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The μSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest μSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in μSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD–CAM composite but also to resin cement/bonding agent/silane used.  相似文献   

11.
This study aimed to evaluate the effectiveness of conventional and sonic activation techniques on push-out bond strength of fiber post cemented with two different monomers containing self-adhesive resin cement (SARC). Four groups (n = 19 each) were made based on the type of SARC (Rely X U200 and Panavia SA) and technique (conventional and sonic activation). After placing the fiber post, each root was sectioned into 2 mm coronal, middle, and apical portions, and a push-out bond strength test was performed using a universal testing machine. The least push-out bond strength (13.0 ± 0.9 MPa) was found in Rely X U200 conventional technique and highest with Panavia SA sonic activation technique (15.4 ± 0.9 MPa). A significant difference was found in push-out bond strength at coronal (p = 0.002), middle (p = 0.002), and apical (p = 0.001) root sections using Rely X U200 cement with sonic activation as compared to the conventional technique. However, no difference (p > 0.05) was noticed between conventional and sonic activation techniques in Panavia SA cement at any root level. Sonic activation can be used as an adjunct with a manual technique to increase bond strength. However, it was noted that 10-MDP monomer containing SARC performed well regardless of techniques.  相似文献   

12.
The freeze–thaw resistant performance of a tunnel fireproof coating (TFC) has an important impact on bonding property and durability. The influence of redispersible emulsion powder, polypropylene fiber and air-entraining agent on TFCs was studied. Transverse fundamental frequency and ultrasonic sound velocity were used to evaluate the damage degree of TFC, and the mechanism was revealed by SEM and pore structure. The results show that the most beneficial effect on bond strength of TFC is redispersible emulsion powder, followed by air-entraining agent, and then polypropylene fiber. After freeze–thaw cycles, the cumulative pore volume of micropores in the TFC increases obviously, while the porosity of macropores does not change significantly. A prediction model was proposed, which can calculate the bond strength from the damage degree of TFC under freeze–thaw cycles. The achievement can promote the application of TFC in cold regions.  相似文献   

13.
The study evaluates the performance of laboratory, single-layered particleboards made out of fructose-hydroxymethylfurfural-bishexamethylenetriamine (SusB) adhesive as a sustainable alternative. Several production parameters such as mat moisture content (MMC), adhesive amount and press time were varied and their effect on the bonding efficiency investigated. The internal bond strength (IB) and thickness swelling after 24 h of water immersion (TS) were taken as evaluation criteria for the bonding efficiency. pMDI-bonded particleboards were produced as fossil-based, formaldehyde-free reference. Particleboard testing was complemented by tensile shear strength measurements and thermal analysis. It was found that the MMC has the highest impact on the internal bond strength of SusB-bonded particleboards. In the presence of water, the reaction enthalpy of the main curing reaction (occurring at 117.7 °C) drops from 371.9 J/mol to 270.5 J/mol, leading to side reactions. By reducing the MMC from 8.7%, the IB increases to 0.61 N/mm2, thus surpassing P2 requirements of the European standard EN312. At a press factor of 10 s/mm, SusB-bonded particleboards have a similar IB strength as pMDI-bonded ones, with 0.59 ± 0.12 N/mm2 compared to 0.59 ± 0.09 N/mm2. Further research on the improvement of the dimensional stabilization of SusB-bonded PBs is needed, as the TS ranges from 30–40%.  相似文献   

14.
The objective of this work was to compare the micro-tensile bond strength (µTBS) of CAD/CAM (Computer-Aided Design/ Computer-Aided Manufacturing) specimens cemented with different pairing of adhesives and resin-cements using two Immediate Dentin Dealing (IDS) approaches in comparison with Delay Dentin Sealing (DDS). Coronal dentin from 108 molars were divided into nine groups (n = 12) depending on the adhesive/resin-cement (A-C) assigned. Lava™ Ultimate (4 × 10 × 10 mm) was cemented according to different strategies: IDS1(cementation after dentin sealing), DDS (dentin sealing and cementation at 2-weeks), IDS2 (immediate dentin sealing and cementation at 2-weeks). Samples were sectioned and tested until failure to determine the µTBS. Failure mode was categorized as dentin/cement (DC), at Lava™ Ultimate/cement (LC) and hybrid (H). Kruskal–Wallis and Mann–Whitney U tests and influence of the type of failure on the µTBS by survival analysis with competing risk was explored. Mostly, µTBS values were equal or higher in IDS2 than DDS. In general, A-Cs that showed higher µTBS, have high percentages of LC failure. Survival analysis with competing risk between DC + H and LC values showed that some A-Cs would significantly increase the µTBS values for IDS2. A-Cs with the highest adhesion values showed a high percentage of fractures at the LC interface, suggesting that the adhesion at the adhesive/dentin interface would be higher.  相似文献   

15.
Materials composed of a polymer matrix reinforced with carbon/glass fibres providing lightweight and superior mechanical properties are widely used as structural components for automotive and aerospace applications. However, such parts need to be joined with various metal alloys to obtain better mechanical performance in many structural elements. Many studies have reported enhancements in polymer–metal bonding using adhesives, adhesive/rivet combined joints, and different surface treatments. This study investigated the influences of various surface treatments on the adhesion between glass-reinforced poly(phenylene) sulphide (PPS) and aluminium alloy during the injection over-moulding process. Adhesion strength was evaluated via the shear test. Correlations for the shear strength of the polymer–metal with different metal–substrate treatments were studied. Since the strongest bonding was attained in the treatment with the highest roughness, this value, as it determines the level of micromechanical interlocking of connected materials, seems to be a critical factor affecting the adhesion strength. Three-dimensional (3D) topographic images characterized with a 3D optical microscope indicated that there was a meaningful influence exerted by the interface topologies of the aluminium substrates used for the over-moulding process. The results further indicated that increases in a substrate’s surface energy in connection with atmospheric plasma treatments negatively influence the final level of the bonding mechanism.  相似文献   

16.
The aim of this study was to evaluate the effect of immediate versus delayed loading times on the microtensile bond strength (μTBS) of restorative materials, including resin-based composite (RBC), resin-modified glass ionomer cement (RMGIC) and glass ionomer cement (GIC), that were bonded to silver diamine fluoride (SDF)-treated demineralized dentin. Ninety caries-free extracted premolar teeth were assigned to three groups (n = 30) loaded with RBC, RMGIC and GIC restorative materials. Each group was further divided into three subgroups (n = 10): subgroup A (control specimens), immediate loading of the restorative material on sound dentin; subgroup B, demineralized dentin, SDF treatment and immediate loading of the restorative material; and subgroup C, demineralized dentin, SDF treatment and restorative material loading a week later. One-way ANOVA and Tukey’s post-hoc tests were performed to compare the μTBS values. The RBC exhibited the highest µTBS, followed by RMGIC and GIC. Multiple comparisons showed an increase in the µTBS in the delayed loading groups irrespective of the restorative material used. The majority of the failure modes were adhesive. Delayed loading of RMGIC for 1 week after SDF application showed significantly higher µTBS than that of immediate loading.  相似文献   

17.
Background: Conventional composites are largely used in pediatric restorative dentistry and demonstrate successful clinical outcomes. However, the need for simplification of operative steps in young or uncooperative children demands reliable alternatives. Therefore, the aim of the present systematic review and meta-analysis was to evaluate the in vitro bond strength of glass ionomer cements (GICs) and self-adhesive flowable composites (SFCs) on deciduous teeth. Methods: A comprehensive literature search according to the PRISMA checklist was manually and electronically performed by two independent reviewers through the following databases: MEDLINE/PubMed, Google Scholar, Scopus, and Embase, to include in vitro studies comparing GICs and SFCs bond strength values of restorations on primary teeth. In addition, three groups of meta-analyses were conducted using random-effects models. Results: Three articles meeting the inclusion criteria were selected and subjected to both qualitative and quantitative assessment. No statistically significant difference was found between SFC versus GIC; however, both groups significantly differed with conventional flowable composites (CFs). Conclusions: Despite the absence of significant difference in bond strength values, SFCs may be considered a valid alternative to GICs in the restoration of deciduous teeth, although CFs proved better in vitro performances.  相似文献   

18.
The aim of this study was to evaluate the effect of CAD/CAM composite thickness on micro-tensile bond strength (µTBS), microhardness (HV), and film thickness (FT) of different luting composites. Composite blocks (6.8 mm × 6.8 mm) were divided into 12 groups according to: CAD/CAM thickness and luting composite. For each group, 21 rods (1 mm × 1 mm) were tested in tension at crosshead speed of 1 mm/min. Fracture modes were categorized as adhesive, mixed, and cohesive. Microhardness (n = 5/group) was assessed using microhardness tester. Film thickness (12-rods/group) was evaluated using a stereomicroscope (×40). Data were analyzed using the two-way ANOVA/Tukey’s HSD test (p = 0.05). Parameters “thickness”, “cement”, and “thickness x cement” showed significant difference on µTBS and HV (p < 0.05). At 2 mm, heated x-tra fil composite showed the highest µTBS (45.0 ± 8.5 MPa), while at 4 mm thickness, Grandio Flow revealed the lowest µTBS (33.3 ± 6.3 MPa). Adhesive, mixed, and cohesive failures were reported. The HV of all composites decreased when photo-polymerized through 4 mm thickness (p < 0.05). Regardless of CAD/CAM thickness, photo-polymerized composites can be successfully used for luting CAD/CAM composite.  相似文献   

19.
In microelectronic packaging technology for three-dimensional integrated circuits (3D ICs), Cu-to-Cu direct bonding appears to be the solution to solve the problems of Joule heating and electromigration (EM) in solder microbumps under 10 μm in diameter. However, EM will occur in Cu–Cu bumps when the current density is over 106 A/cm2. The surface, grain boundary, and the interface between the Cu and TiW adhesion layer are the three major diffusion paths in EM tests, and which one may lead to early failure is of interest. This study showed that bonding strength affects the outcome. First, if the bonding strength is not strong enough to sustain the thermal mismatch of materials during EM tests, the bonding interface will fracture and lead to an open circuit of early failure. Second, if the bonding strength can sustain the bonding structure, voids will form at the passivation contact area between the Cu–Cu bump and redistribution layer (RDL) due to current crowding. When the void grows along the passivation interface and separates the Cu–Cu bump and RDL, an open circuit can occur, especially when the current density and temperature are severe. Third, under excellent bonding, when the voids at the contact area between the Cu–Cu bump and RDL do not merge together, the EM lifetime can be more than 5000 h.  相似文献   

20.
The aim of this study was to assess the effect of application of a recently developed bio-adhesive (Impladhesive) to abutment screw threads on the removal torque value and rotational misfit at the implant–abutment junction. This in vitro study evaluated 20 implant fixtures and 20 straight abutments. Specimens were randomly divided into two groups (n = 10) with/without adhesive application. In the adhesive group, the abutment was dipped in Impladhesive before torquing. In the control group, the abutment was torqued conventionally without adhesive application. The removal torque value was recorded after completion of the cyclic loading of 500,000 cycles with 2 Hz frequency and 75 N load. Rotational misfit was recorded using a video measuring machine. After applying the torque, the change in the bisector angle on the abutment hex was recorded for each implant. The biocompatibility of Impladhesive was evaluated using a MTT cell vitality assay. Normal distribution of data was assessed using the Kolmogorov–Smirnov test. Data were analyzed using a t-test and Pearson’s correlation coefficient The application of Impladhesive at the implant–abutment interface resulted in significantly greater mean removal torque value compared to the control group (p = 0.008). In addition, the mean rotational misfit at the implant–abutment interface was significantly lower in the use of Impladhesive compared to the control group (p = 0.001). In addition, the cell vitality was found to be greater than 80% at all evaluated time points. It can be concluded that the application of Impladhesive on the abutment screw significantly decreased rotational misfit and increased the removal torque value. Future studies are needed to evaluate the efficacy of this bio-adhesive an in vivo setting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号