首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 617 毫秒
1.
The use of new prosthetic materials makes it necessary to establish adequate hygienic protocols. It was decided to make prosthetic crowns from four different materials: composite, lithium disilicate, metal ceramic, and zirconium, and to evaluate the effects on the surfaces of four different instruments through SEM and roughness analysis: manual steel curette, manual titanium curette, ultrasonic steel insert, and ultrasonic peek insert. Forty crowns were made, ten of each type of material. For each material, five crowns were manually instrumented with steel inserts (curette 11-12, PDT, Missoula, MT, USA) and titanium (Wingrove 3-4, PDT, Missoula, MT, USA) on the lingual and buccal surfaces, respectively, and the other five crowns were instrumented with an ultrasonic peek insert (ICS-IC1, Mectron, Carasco, Italy) on the buccal surface and steel (PS, EMS, Nyon, Switzerland) on the lingual surface. At this point, surface roughness analysis was carried out. The data were analyzed with a Kolmogorov–Smirnov test. Therefore, it was decided to conduct two analyses with a Kruskal–Wallis test and Bonferroni post hoc test. Then, the instrumented crowns were analyzed by SEM. The analysis of the data shows that the highest average roughness was within the composite group, while the best material appeared to be disilicate. Significant differences existed between the groups, between the materials, and between the different instruments (p-value < 0.05). In the qualitative analysis carried out by SEM, the classic steel insert eliminated the residues of golden finishing. The peek insert created alterations on all tested surfaces. The steel curette did not create particular problems, with the exception of zirconium, where it was possible to observe some scratch lines. Instrumentation with the titanium curette created deeper incisions than the steel curette in the composite and disilicate. The best results came from the ultrasonic steel insert, while the best material appeared to be disilicate.  相似文献   

2.
The wide application of additive manufacturing in dentistry implies the further investigation into oral micro-organism adhesion and biofilm formation on vat-photopolymerization (VP) dental resins. The surface characteristics and microbiological analysis of a VP dental resin, printed at resolutions of 50 μm (EG-50) and 100 μm (EG-100), were evaluated against an auto-polymerizing acrylic resin (CG). Samples were evaluated using a scanning electron microscope, a scanning white-light interferometer, and analyzed for Candida albicans (CA) and Streptococcus mutans (SM) biofilm, as well as antifungal and antimicrobial activity. EG-50 and EG-100 exhibited more irregular surfaces and statistically higher mean (Ra) and root-mean-square (rms) roughness (EG-50-Ra: 2.96 ± 0.32 µm; rms: 4.05 ± 0.43 µm/EG-100-Ra: 3.76 ± 0.58 µm; rms: 4.79 ± 0.74 µm) compared to the CG (Ra: 0.52 ± 0.36 µm; rms: 0.84 ± 0.54 µm) (p < 0.05). The biomass and extracellular matrix production by CA and SM and the metabolic activity of SM were significantly decreased in EG-50 and EG-100 compared to CG (p < 0.05). CA and SM growth was inhibited by the pure unpolymerized VP resin (48 h). EG-50 and EG-100 recorded a greater irregularity, higher surface roughness, and decreased CA and SM biofilm formation over the CG.  相似文献   

3.
Candida albicans (C. albicans) biofilm is a common etiological factor in denture stomatitis. The purpose of this study was to investigate the effects of incorporating 2-methacryloyloxyethyl phosphorylcholine (MPC) as a protein repellent into a new high-impact denture acrylic (HIPA) resin on the surface roughness, solution pH, and C. albicans biofilm adhesion to the denture base. The new acrylic denture resin base was formulated by mixing MPC into HIPA resin at mass fractions of 1.5%, 3%, and 4.5%. Surface roughness was measured using a Mitutoyo surface roughness tester. C. albicans biofilm growth and viability were assessed via colony forming unit counts. The pH of the biofilm growth medium was measured using a digital pH meter. Adding MPC to the HIPA resin at percentages of 1.5% and 3% increased the roughness values significantly (p < 0.05), while adding 4.5% MPC resulted in no difference in roughness values to that of the control group (p > 0.05). All experimental groups demonstrated neutral pH values (pH ≅ 7) and were not significantly different from each other (p > 0.05). Incorporating 2-methacryloyloxyethyl phosphorylcholine at 4.5% resulted in a significant (≅1 log) colony-forming unit reduction compared with the control group with 0% MPC (p < 0.05). A fungal-retarding denture acrylic resin was developed through the incorporation of MPC for its protein-repelling properties. This newly developed denture acrylic material has the potential to prevent oral microbial infections, such as denture stomatitis.  相似文献   

4.
The aim of this study was to investigate the element composition and grain size of commercial dental instruments used for ultrasonic scaler tips, which are composed of stainless-steel materials. The differences in mechanical properties and wear resistances were compared. The samples were classified into 4 groups in accordance with the manufacturer, Electro Medical Systems, 3A MEDES, DMETEC and OSUNG MND, and the element compositions of each stainless-steel ultrasonic scaler tip were analyzed with micro-X-ray fluorescence spectrometry (μXRF) and field-emission scanning electron microscopy (FE-SEM) with energy-dispersive X-ray spectroscopy (EDS). One-way ANOVA showed that there were significant differences in shear strength and Vickers hardness among the stainless-steel ultrasonic scaler tips depending on the manufacturer (p < 0.05). The mass before and after wear were found to have no significant difference among groups (p > 0.05), but there was a significant difference in the wear volume loss (p < 0.05). The results were then correlated with μXRF results as well as observations of grain size with optical microscopy, which concluded that the Fe content and the grain size of the stainless steel have significant impacts on strength. Additionally, stainless-steel ultrasonic scaler tips with higher Vickers hardness values showed greater wear resistance, which would be an important wear characteristic for clinicians to check.  相似文献   

5.
High-purity magnesium (Mg) is a promising biodegradable metal for oral and maxillofacial implants. Appropriate surface roughness plays a critical role in the degradation behavior and the related cellular processes of biodegradable Mg-based metals. Nevertheless, the most optimized surface roughness has been questionable, especially for Mg-based oral and maxillofacial implants. Three representative scales of surface roughness were investigated in this study, including smooth (Sa < 0.5 µm), moderately rough (Sa between 1.0–2.0 µm), and rough (Sa > 2.0 µm). The results indicated that the degradation rate of the Mg specimen in the cell culture medium was significantly accelerated with increased surface roughness. Furthermore, an extract test revealed that Mg with different roughness did not induce an evident cytotoxic effect. Nonetheless, the smooth Mg surface had an adversely affected cell attachment. Therefore, the high-purity Mg with a moderately rough surface exhibited the most optimized balance between biodegradability and overall cytocompatibility.  相似文献   

6.
Although some reports suggest that taper-slip cemented stems may be associated with a higher periprosthetic femoral fractures rate than composite-beam cemented stems, few studies have focused on the biomaterial effect of the polished material on the stem–cement interface. The purpose of this study was to investigate the relationship between surface roughness of materials and bone cement. Four types of metal discs—cobalt-chromium-molybdenum alloy (CoCr), stainless steel alloy 316 (SUS), and two titanium alloys (Ti-6Al-4V and Ti-15Mo-5Zr-3Al)—were prepared. Five discs of each material were produced with varying degrees of surface roughness. In order to evaluate surface wettability, the contact angle was measured using the sessile drop method. A pin was made using two bone cements and the frictional coefficient was assessed with a pin-on-disc test. The contact angle of each metal increased with decreasing surface roughness and the surface wettability of metal decreased with higher degrees of polishing. With a surface roughness of Ra = 0.06 μm and moderate viscosity bone cement, the frictional coefficient was significantly lower in CoCr than in SUS (p = 0.0073). In CoCr, the low adhesion effect with low frictional coefficient may result in excessive taper-slip, especially with the use of moderate viscosity bone cement.  相似文献   

7.
This paper assesses the impact of preheating of adhesive cement on the fracture resistance of lithium disilicate and zirconia restorations. Methods: A total of 80 human maxillary premolar teeth were assigned into 8 groups (n = 10) according to material type (either lithium disilicate or zirconia) and type of resin cement (either LinkForce or Panavia SA) with preheating temperature at 54 °C or at room temperature (25 °C). Teeth were prepared and restored with either lithium disilicate or zirconia restorations. After cementation, specimens were thermal cycled (10,000 cycles, 5 °C/55 °C), then load cycled for 240,000 cycles (50 N). Each specimen was statically loaded until fracture and the load (N) at fracture was recorded, then the failure mode was detected. Statistical analysis of data was performed (p ≤ 0.05). Results: There was no significant difference (p = 0.978) in fracture mean values between LinkForce and Panavia SA. Statistically significant difference (p = 0.001) was revealed between fracture resistance of lithium disilicate restorations cemented with LinkForce at 25 °C and at 54 °C; however there was no significant difference (p = 0.92) between the fracture resistance of lithium disilicate restorations cemented with Panavia SA used at 25 °C and at 54 °C. Regarding the interaction between ceramic material, cement type, and cement preheating, there was no significant effect (p > 0.05) in fracture resistance. The cement type does not influence the fracture resistance of ceramic restorations. Preheating of resin cement has negatively influenced the fracture resistance of all tested groups, except for lithium disilicate cemented using LinkForce cement.  相似文献   

8.
Background. This study aimed to determine the kinetic frictional force (FF) of the recently produced TiNbTaZrO (Gummetal) orthodontic wire and compare it to the widely used wires of stainless steel (SS), nickel-titanium (NiTi), cobalt-chromium (CoCr) and titanium-molybdenum (TiMo) alloys. Methods. Five types of 0.016″ × 0.022″ wires were ligated with elastic ligatures to 0.018″ × 0.025″ SS brackets. The dynamic FFs between the brackets and ligated wires were measured utilizing a specialized tensile tester machine. Prior sample sizes for different archwires were conducted using power analysis for the general linear models. The existence of significant differences in FF between examined materials was initially confirmed by the one-way analysis of variance (ANOVA) with further evidence of pairwise differences by Tukey’s Honest Significant Difference test. Results. The pairwise differences between means of kinetic FFs for NiTi, CoCr, and Gummetal wires were not statistically significant (adjusted p-value > 0.05). Stainless steel alloy presented the lowest FF values significantly different from other groups (adjusted p-value < 0.05). On the contrary, TiMo wires showed significantly greater FFs (adjusted p-value < 0.05) than other alloys. Conclusions. Gummetal orthodontic wire exhibits similar frictional resistance as NiTi and CoCr wires. Bendable TiNbTaZrO wire might be used for sliding mechanics due to its favorable frictional properties.  相似文献   

9.
The aim of this study was to evaluate the effect of modification with liquid rubber on the adhesion to tooth tissues (enamel, dentin), wettability and ability to inhibit bacterial biofilm formation of resin-based dental composites. Two commercial composites (Flow-Art–flow type with 60% ceramic filler and Boston–packable type with 78% ceramic filler; both from Arkona Laboratorium Farmakologii Stomatologicznej, Nasutów, Poland) were modified by addition of 5% by weight (of resin) of a liquid methacrylate-terminated polybutadiene. Results showed that modification of the flow type composite significantly (p < 0.05) increased the shear bond strength values by 17% for enamel and by 33% for dentine. Addition of liquid rubber significantly (p < 0.05) reduced also hydrophilicity of the dental materials since the water contact angle was increased from 81–83° to 87–89°. Interestingly, modified packable type material showed improved antibiofilm activity against Steptococcus mutans and Streptococcus sanguinis (quantitative assay with crystal violet), but also cytotoxicity against eukaryotic cells since cell viability was reduced to 37% as proven in a direct-contact WST-8 test. Introduction of the same modification to the flow type material significantly improved its antibiofilm properties (biofilm reduction by approximately 6% compared to the unmodified material, p < 0.05) without cytotoxic effects against human fibroblasts (cell viability near 100%). Thus, modified flow type composite may be considered as a candidate to be used as restorative material since it exhibits both nontoxicity and antibiofilm properties.  相似文献   

10.
This study evaluated the effects of different simulated chairside grinding and polishing protocols on the physical and mechanical properties of surface roughness, hardness, and flexural strength of monolithic zirconia. Sintered monolithic zirconia specimens (15 mm × 3 mm × 3 mm) were abraded using three different burs: diamond bur, modified diamond bur (zirconia specified), and tungsten carbide bur, along with a group of unprepared specimens that served as a control group. The study was divided into two phases, Phase 1 and Phase 2. Surface roughness, surface hardness, and flexural strength were assessed before and after the grinding procedure to determine the ‘best test group’ in Phase 1. The best abrasive agent was selected for Phase 2 of the study. The specimens in Phase 2 underwent grinding with the best abrasive agent selected. Following the grinding, the specimens were then polished using commercially available diamond polishing paste, a porcelain polishing kit, and an indigenously developed low-temperature sintered zirconia slurry. The physical and mechanical properties were again assessed. Results were analyzed using one-way ANOVA test. Specimens were observed under scanning electron microscopy (SEM) and X-ray diffraction (XRD) for their microstructure and crystalline phases, respectively. Grinding with diamond burs did not weaken zirconia (p > 0.05) but produced rougher surfaces than the control group (p < 0.05). Tungsten carbide burs did not significantly roughen the zirconia surface. However, specimens ground by tungsten carbide burs had a significantly reduced mean flexural strength (p < 0.05) and SEM revealed fine surface cracks. Phase transformation was not detected by XRD. Polishing with commercially available polishing agents, however, restored the surface roughness levels to the control group. Dental monolithic zirconia ground with tungsten carbide burs had a significantly reduced flexural strength and a smooth but defective surface. However, grinding with diamond burs roughened the zirconia surface. These defects may be reduced by polishing with commercially available polishing agents. The use of tungsten carbide burs for grinding dental zirconia should not be advocated. Grinding with diamond abrasives does not weaken zirconia but requires further polishing with commercially available polishing agents.  相似文献   

11.
Purpose: This study aims to evaluate the effectiveness of two ceramic and two composite polishing systems for a novel chairside computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate ceramic with three-dimensional and two-dimensional microscopy images. This ceramic material can be used for implant-supported or tooth-borne single-unit prostheses. Materials and Methods: Sixty flat samples of novel chairside CAD/CAM reinforced lithium disilicate ceramic (Amber Mill, Hass Bio) were divided into five groups (n = 15/group) and treated as follows: Group 1 (NoP), no polished treatment; group 2 (CeDi), polished with ceramic Dialite LD (Brasseler USA); group 3, (CeOp) polished with ceramic OptraFine (Ivoclar Vivadent); group 4, (CoDi) polished with composite DiaComp (Brasseler USA), and group 5 (CoAs), polished with composite Astropol (Ivoclar Vivadent). The polished ceramic surface topography was observed and measured with three-dimensional and two-dimensional images. Results: All polishing systems significantly reduced the surface roughness compared with the non-polished control group (Sa 1.15 μm). Group 2 (CeDi) provided the smoothest surface arithmetical mean eight with 0.32 μm, followed by group 3 (CeOp) with 0.34 μm. Group 5 (CoAs) with 0.52 μm provided the smoothest surface among the composite polishing kits. Group 4 (CoDi) with 0.66 μm provided the least smooth surface among all polishing systems tested. Conclusions: Despite the effectiveness of ceramic polishing systems being superior to composite polishing systems of the CAD/CAM lithium disilicate restorative material, both polishing systems significantly improved the smoothness.  相似文献   

12.
Background: In this study, we assess the effect produced on roughness and gloss of full-body bulk-fill materials by different finishing and polishing systems. Methods: Four full-body bulk-fill materials were tested: SonicFill2 (SF), Filtek Bulk Fill Posterior Restorative (FB), Tetric EvoCeram bulk-fill (EC), and Fill-Up! (FU). Sixty discs per material (2 mm in thickness and 7 mm in diameter) were obtained and randomly assigned (n = 15) to four finishing and polishing methods: Sof-Lex Spiral Wheels (SW), HiLusterPLUS (HL), Astropol (AP), and Opti1Step (OS). Surface roughness and gloss were then measured. Results: For roughness, material and surface treatment were significant factors (p < 0.001) with SF = FB = EC < FU and AP < SW < HL = OS. Material and surface treatment had a significant effect also on gloss (p < 0.001), with SF > FB = EC > FU and SW > AP > HL > OS. Conclusions: The tested combinations of bulk-fill and polishing systems provided clinically acceptable results with regard to roughness, while the outcome was poor for gloss. Multistep finishing/polishing systems were able to produce smoother surfaces on full-body bulk-fill materials compared to simplified ones.  相似文献   

13.
The purpose of this study was to demonstrate the time-efficiency and the clinical effectiveness of chairside-fabricated lithium disilicate single crowns by digital impressions compared to the conventional method. Thirteen patients requiring a single crown on the maxillary or mandibular premolar or first molar were assigned as study subjects. The impressions were obtained using the conventional method and two digital methods with intraoral scanners: AEGIS.PO (Digital Dentistry Solution, Seoul, Korea) and CEREC Omnicam (Sirona, Bensheim, Germany). Two types of lithium disilicate single crowns were obtained; a reference crown (by conventional workflow) and a chairside crown (by digital workflow). The total time taken for fabricating the chairside crown was recorded. The replica technique was performed to compare the marginal and internal fit of the two types of crowns. In addition, accuracy of the intraoral scanners was evaluated by the best-fit alignment method. The difference between the groups was analyzed using the two-tailed paired t-test or one-way ANOVA, followed by the Student–Newman–Keuls test for multiple comparisons. Statistical significance was accepted at p < 0.05 for all statistical tests. The time required to obtain the impressions by the AEGIS (7:16 ± 1:50 min:s) and CEREC (7:29 ± 2:03 min:s) intraoral scans was significantly lower than the conventional method (12:41 ± 1:16 min:s; p < 0.001). There was no significant difference between the intraoral scanners. The total working time to fabricate the chairside crown averaged 30:58 ± 4:40 min:s. The average marginal gap was not significantly different between the reference (107.86 ± 42.45 µm) and chairside (115.52 ± 38.22 µm) crowns (p > 0.05), based on results of replica measurement. The average internal gaps were not significantly different. The average value of the root mean square between the AEGIS (31.7 ± 12.3 µm) and CEREC (32.4 ± 9.7 µm) scans was not significantly different (p > 0.05). Intraoral scans required a significantly shorter impression time than the conventional method, and it was possible to fabricate a lithium disilicate crown in a single visit. There were no statistically significant differences in the fit of the restorations and accuracy of the intraoral scanners compared to the conventional workflow.  相似文献   

14.
The presence of nickel could modify bacterial behavior and susceptibility to antimicrobial agents. Adhesion and biofilm formation on orthodontic archwires can be a source of bacterial colonization and possible health hazards. Staphylococcus aureus was subjected to exposure and adaptation to various sub-inhibitory concentrations of nickel. Five strains of bacteria adapted to nickel in concentrations of 62.5–1000 μg/mL were tested for adhesion and biofilm formation on nickel-titanium archwires. Archwires were previously incubated in artificial saliva. Bacteria were incubated with orthodontic wire with stirring for 4 h (adhesion) and 24 h (biofilm formation). The number of adherent bacteria was determined after sonication and cultivation on the Muller-Hinton agar. Disk diffusion method was performed on all bacteria to assess the differences in antimicrobial susceptibility. Bacteria adapted to lower concentrations of nickel adhered better to nickel-titanium than strains adapted to higher concentrations of nickel (p < 0.05). Biofilm formation was highest in strains adapted to 250 and 500 μg/mL of nickel (p < 0.05). The highest biofilm biomass was measured for strains adapted to 250 μg/mL, followed by those adapted to 1000 μg/mL. Bacteria adapted to lower concentrations of nickel demonstrated lower inhibition zone diameters in the disk diffusion method (p < 0.05), indicating increased antimicrobial resistance. In conclusion, bacteria adapted to 250 μg/mL of nickel ions adhered better, demonstrated higher biofilm formation and often had higher antimicrobial resistance than other adapted and non-adapted strains.  相似文献   

15.
Streptococcus mutans is considered a major cariogenic bacterium. Most anti-cariogenic dentifrices are limited by a short exposure time. The aim of the present study was to test the hypothesis that adding a mucoadhesive agent to the formulation may increase its bioavailability and efficacy. We tested the effect of adding hydroxyethyl cellulose (HEC) to an herbal extract solution containing lavender, echinacea, sage, and mastic gum, which have been previously shown to be effective against Streptococcus mutans. Mucin-coated wells were treated with four test solutions: saline, herbal extracts, herbal extracts with HEC, and chlorhexidine. The wells were incubated with Streptococcus mutans and studied for biofilm formation (Crystal violet assay), acid production (lactate assay), acid tolerance (ATPase assay), and exopolysaccharide (EPS) production using fluorescent microscopy. The results showed that the addition of HEC to the herbal extract solution caused a significant reduction in Streptococcus mutans biofilm formation, lactic acid production, and EPS quantity (p < 0.001). These results suggest that HEC may be a beneficial added excipient to herbal extracts in an anti-cariogenic formulation.  相似文献   

16.
The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (TiGrade 2), Ti6Al4V grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (TiGrade 5), Ti6Al4V grade 23 as it comes from a CAD-CAM milling device (TiGrade 23), and CAD-DMLS TiGrade 5 polished with an abrasive disc (TiGrade 5 polished). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement. Five specimens/implant types were used in the bacterial adhesion experiments. Autoclaved implant specimens were placed in petri plates and immersed in saliva solution for 30 min at room temperature and then washed 3× with 1× PBS. Bacterial suspensions of each strain were made and added to the specimens after saliva treatment. Biofilm was allowed to form for 24 h at 37 °C and the adhered bacteria was calculated. Tooling techniques had an insignificant effect on the bacterial adhesion by all the bacterial strains studied. However, there was a significant difference in biofilm formation between the saliva-treated and non-saliva-treated implants. Saliva contamination enhanced S. mutans, S. aureus, and E. faecalis adhesion in all material types studied. S. aureus was found to be the most adherent strain in the saliva-treated group, whereas E. coli was the most adherent strain in the non-saliva-treated group. In conclusion, CAD-CAM tooling techniques have little effect on bacterial adhesion. Saliva coating enhances the biofilm formation; therefore, saliva contamination of the implant must be minimized during implant placement. Further extensive studies are needed to evaluate the effects of surface treatments of the titanium implant on soft tissue response and to prevent the factors causing implant infection and failure.  相似文献   

17.
The characteristics of the denture base surface, in combination with the oral environment, promote the colonization and development of Candida albicans biofilm, which is the main cause of denture stomatitis. This study evaluated the effectiveness of fibrin biopolymer with digluconate chlorhexidine or Punica granatum alcoholic extract to prevent C. albicans biofilm. Conventional heat polymerized and pre-polymerized poly(methyl methacrylate) (PMMA) circular specimens (10 × 2 mm) were fabricated (n = 504) and randomly divided into groups: no treatment (control—CT), fibrin biopolymer coating (FB), fibrin biopolymer with P. granatum (FBPg), or digluconate of chlorhexidine (FBCh) coating. The specimens were inoculated with C. albicans SC5314 (1 × 107 cells/mL) and incubated for 24, 48, and 72 h. Crystal violet and colony-forming unit assays were used to quantify the total biofilm biomass and biofilm-living cells. A qualitative analysis was performed using confocal laser scanning microscopy. Data obtained are expressed as means and standard deviations and were statistically analyzed using a three-way analysis of variance (α = 0.05). The FBPg and FBCh groups inhibited the growth of C. albicans biofilm in both PMMA materials analyzed, with FBCh performing better in all periods evaluated (p < 0.0001). The colony forming unit (CFU) assay showed that the FB group favored the C. albicans biofilm growth at 24 h and 48 h (p < 0.0001), with no differences with CT group at 72 h (p = 0.790). All groups showed an enhancement in biofilm development up to 72 h (p < 0.0001), except the FBCh group (p = 0.100). No statistical differences were found between the PMMA base materials (p > 0.050), except in the FB group (p < 0.0001). Fibrin biopolymer, albeit a scaffold for the growth of C. albicans, when combined with chlorhexidine digluconate or P. granatum, demonstrated excellent performance as a drug delivery system, preventing and controlling the formation of denture biofilm.  相似文献   

18.
The purpose of this study was to investigate the effect of silane-containing universal adhesives on the bonding strength of lithium disilicate. Two-hundred-and-forty lithium disilicate blocks were divided into 16 groups according to the following surface treatments: hydrofluoric acid (HF)-treated or not, silane-treated or not, and the type of universal adhesive used (All-Bond Universal (ABU); Prime & bond (PB); Clearfil Universal Bond (CU); Single bond Universal (SBU)). After surface treatment, resin discs were bonded to each lithium disilicate using dual-cure resin cement. Bonded specimens were stored in distilled water for 24 h and then subjected to microtensile bond strength (μTBS) test. Failure modes were examined under stereomicroscope. Microscopic observation of bonded interfaces was analyzed using scanning electron microscopy. The μTBS data were statistically analyzed. Regardless of silane treatment, all groups treated with HF showed higher bonding strengths compared to those that were not treated with HF (p < 0.05). In groups treated with HF, the bonding strength increased after silane application (p < 0.05) except PB and CU (p > 0.05). Adhesive failures were dominant in all groups, but some mixed failures were observed in ABU treated with HF and silane. While most of the specimens that were not treated with silane after HF application only showed loose bonding between the ceramic and resin cement due to partial gaps, the specimens treated with silane application after HF showed a tight ceramic–resin interface. In conclusion, the silane in universal adhesives did not effectively improve the bonding strength between lithium disilicate and resin cement.  相似文献   

19.
The aim of this study was to compare the load-to-failure resistance and optical properties of nano-lithium disilicate (NLD) with lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) in different aging processes. Thirty crowns were milled from NLD, LDS, and ZLS (n = 10). All crowns were subjected to thermomechanical aging and loaded until catastrophic failure. Ten specimens from each material were prepared in two different thicknesses (0.7 mm and 1.5 mm, n = 5), and color coordinates were measured before and after coffee thermocycling. Color differences (ΔE00) and relative translucency parameter (RTP) were calculated. Data were analyzed by using ANOVA and Bonferroni-corrected t-tests (α = 0.05). ZLS had the highest load-to-failure resistance (p ≤ 0.002), while the difference between LDS and NLD was nonsignificant (p = 0.776). The interaction between material type and thickness affected ΔE00 (p < 0.001). Among the 0.7 mm thick specimens, ZLS had the lowest ΔE00 (p < 0.001). Furthermore, 1.5 mm thick ZLS had lower ΔE00 than that of 1.5 mm thick LDS (p = 0.036). Other than ZLS (p = 0.078), 0.7 mm thick specimens had higher ΔE00 (p < 0.001). The interaction between material type, thickness, and thermocycling affected RTP (p < 0.001). Thinner specimens presented higher RTP (p < 0.001). NLD and LDS had higher RTP than ZLS (p ≤ 0.036). However, 0.7 mm thick specimens had similar RTP after coffee thermocycling (p ≥ 0.265). Coffee thermocycling reduced the RTP values of 0.7 mm thick NLD (p = 0.032) and LDS (p = 0.008). NLD may endure the occlusal forces present in the posterior region. However, long-term coffee consumption may impair the esthetics of restorations particularly when thin NLD is used.  相似文献   

20.
There is still a lack of consensus concerning the recommended etching concentration, application time and type of silane when bonding lithium disilicate-reinforced glass ceramics manufactured by CAD/CAM. The purpose of this study was thus to conduct an in vitro study which investigates the influence of hydrofluoric acid (HF) concentration, etching time and silane type on the microtensile bond strength (μTBS) of lithium disilicate to resin composites. Thirty-nine IPS e.max CAD blocks were randomly divided between thirteen groups (n = 3). The variables were HF concentration (9.5 or 4.9%), etching time (20 or 60 s) and silane type (Bis-Silane, Monobond Plus and ESPE Sil Silane). The blocks were cut into beams, aged for 10,000 cycles in a thermocycler and submitted to tensile stress to determine μTBS. A control group featuring the Monobond Etch & Prime (MEP) agent that combines etching/silanisation into a simultaneous process was also added. This group was discarded from the analysis due to only having pre-test failures. The data were analysed using a three-way ANOVA (α = 0.05). The HF concentration, etching time and silane type significantly influenced μTBS (p < 0.001). Significant interactions between time and silane type (p = 0.004), HF concentration and silane type (p < 0.001) and among the three factors (p < 0.001) were noted. Etching lithium disilicate with 9.5% HF (60 s), followed by the application of Bis-Silane, resulted in the highest μTBS (16.6 ± 9.0 MPa). The highest concentration and etching time under study, combined with a two-part silane, resulted in the highest bond strength, while the application of MEP showed a complete pre-test failure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号