首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
The use of the StarClose vascular closure device for puncture site hemostasis after therapeutic endovascular interventions performed through the axillary artery under anticoagulant therapy in six patients is reported. Three minor complications, including hematoma, prolonged hemostasis, and pain, occurred in three patients. Based on this limited experience, this method can be used safely for axillary artery puncture site hemostasis after endovascular procedures without significant complications.  相似文献   

3.
Placement of a prophylactic retrievable inferior vena cava (IVC) filter was requested in a 73-year-old woman with nickel hypersensitivity resulting in a clinical dilemma. Given that all retrievable filters contain nickel, the published literature and the Manufacturer and User Facility Device Experience (MAUDE) database were reviewed; no documented case of IVC filter placement in a patient with nickel hypersensitivity or reported hypersensitivity reaction in a patient after IVC filter placement could be identified. This article presents the uneventful course of the case described and a review of the literature and recommendations on use of nickel-containing devices in patients with nickel hypersensitivity.  相似文献   

4.
The recent generation of AMPLATZER Vascular Plug (AVP; ie, the AVP IV) was used for the occlusion of eight pulmonary arteriovenous malformations (PAVMs) in five patients. A treatment was considered successful when there was a reduction or disappearance of the aneurysmal sac. At a mean follow-up of 20.1 months, no recanalization of PAVMs was observed on multidetector computed tomographic angiography. This shows the AVP IV to be safe and effective as an embolic device to occlude PAVMs.  相似文献   

5.
PurposeTo compare the safety of permanent and retrievable inferior vena cava (IVC) filters by reviewing the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database.Materials and MethodsThe MAUDE database was reviewed from January 1, 2009, to December 31, 2012. Product class search criteria were “filter, intravascular, cardiovascular.” Type of device used and specific adverse events (AEs) were recorded.ResultsFor the period January 2009–December 2012, 1,606 reported AEs involving 1,057 IVC filters were identified in the MAUDE database . Of reported AEs, 1,394 (86.8%) involved retrievable inferior vena cava filters (rIVCFs), and 212 (13.2%) involved permanent inferior vena cava filters (pIVCFs) (P < .0001). Reported AEs included fracture, migration, limb embolization, tilt, IVC penetration, venous thromboembolism and pulmonary embolism, IVC thrombus, and malfunctions during placement. Each specific AE was reported with significantly higher frequency in rIVCFs compared with pIVCFs. The most common reported complication with rIVCFs was fracture, whereas the most commonly reported complications with pIVCFs were placement malfunctions. For rIVCFs, the most commonly reported AE varied depending on filter brand.ConclusionsThe MAUDE database reveals that complications occur with significantly higher frequency with rIVCFs compared with pIVCFs. This finding suggests that the self-reported complication rate with rIVCFs is significantly higher than the self-reported complication rate with pIVCFs.  相似文献   

6.
PurposeTo examine the risk of femoral access site complications in patients undergoing carotid stent placement who were treated with a closure device compared with patients who were not treated with a closure device.Materials and MethodsA national, multihospital patient database, the Premier Perspective database, was used to identify patients hospitalized for carotid stent placement from 2006–2011. To reduce potential selection bias, a propensity score was generated for each patient using relevant clinical variables. Propensity score adjustment via 1:1 matching was performed on patients who did and did not receive a closure device. Primary outcomes were minor femoral access site complications and major complications requiring procedural intervention. Secondary outcomes included in-hospital mortality, stroke, and blood transfusion.ResultsAmong 12,287 patients who underwent carotid stent placement at 217 hospitals, 6,398 (52%) received a closure device on the day of the procedure. After propensity score matching, patients who received a closure device had a lower likelihood of minor access site complications (4.2% vs 5.4%; odds ratio = 0.77; 95% confidence interval, 0.55–0.93; P = .0071) compared with patients who did not receive a closure device; however, this difference was small and likely not clinically relevant. Both groups had a similar risk of major access site complications (P = .32), in-hospital mortality (P = .0520), and stroke (P = .31).ConclusionsUse of a closure device was not associated with a substantially reduced risk of major adverse events after carotid stent placement and was associated with only a small improvement in minor access site complications.  相似文献   

7.
PurposeTo describe an artifact that mimics thrombosis when assessing abdominal vasculature on magnetic resonance (MR) imaging using ferumoxytol in patients with contraindications to gadolinium-based contrast agents and to evaluate factors that may contribute to this artifact.Materials and MethodsThree radiologists in consensus retrospectively evaluated 61 abdominal MR imaging examinations using ferumoxytol as an intravenous contrast agent for the presence of an observed artifact that can mimic thrombosis. Patient demographics and contrast agent bolus concentrations were compared with an unpaired Wilcoxon signed rank test.ResultsAn artifact mimicking thrombosis was observed in 30 of 61 examinations, all on the arterial phase sequences. In examinations with this artifact, the average concentration of administered ferumoxytol was greater than in examinations where the artifact was not observed (P < .01). Several additional vascular findings were observed, including portal vein thrombosis (n = 2) and aneurysm (n = 1), renal vein thrombosis (n = 2), abdominal aortic aneurysm (n = 1), abdominal and iliac artery dissection (n = 3), and sequelae of portal hypertension (n = 8).ConclusionsAlthough MR imaging using ferumoxytol as an intravenous contrast agent can be useful in detecting abdominal vascular abnormalities, an artifact mimicking vascular thrombosis was observed in nearly half of the examinations.  相似文献   

8.
Three patients with complete iliocaval thrombosis causing symptomatic leg swelling failed initial treatment with standard pharmacomechanical techniques. The occluded segments of the inferior vena cava and iliac veins were subsequently treated with the AngioVac Cannula (AngioDynamics, Latham, New York) and extracorporeal venous bypass circuit. In each patient, symptoms improved after treatment. This report discusses potential benefits and ancillary techniques of using the AngioVac device for iliocaval venous thrombosis.  相似文献   

9.
Balloon-assisted embolization performed by delivering Onyx ethylene vinyl alcohol copolymer through a dual-lumen coaxial balloon microcatheter is a new technique for the management of peripheral vascular lesions. This technique does not require an initial reflux of Onyx to form around the tip of the microcatheter before antegrade flow of Onyx can commence. In a series of four patients who were treated with the use of this technique, the absence of significant reflux of Onyx was noted, as were excellent navigability and easy retrieval of the balloon microcatheter. However, in one patient, there was inadvertent adverse embolization of a digital artery, which was not caused by reflux of Onyx but could still be related to balloon inflation.  相似文献   

10.
PurposeTo examine the safety and efficacy of the SpiderFX embolic protection device (EPD) in the below-the-knee (BTK) circulation in patients with critical limb ischemia (CLI).Materials and MethodsA single-center retrospective review was performed to identify patients with CLI and single-vessel runoff in whom the SpiderFX EPD was used in the BTK circulation. Technical success and device-related complications were the primary endpoints. Retrieval of macroscopic debris in the EPD, 1-year freedom from major adverse limb events (MALEs), and 30-day perioperative death were also evaluated. A major amputation, surgical bypass, endovascular thrombectomy, or endovascular thrombolysis was considered a MALE. Thirty-six patients (21 men; mean age, 75.8 y) treated between 2008 and 2013 had endovascular revascularization with use of the SpiderFX EPD in the BTK circulation.ResultsThe SpiderFX EPD was successfully deployed in all cases; the technical success rate of revascularization was 100%. Two minor and zero major complications were observed related to the SpiderFX. Two MALEs, a major amputation and a subsequent surgical bypass, were observed in the cohort. All MALEs occurred within 1 year of treatment (1-y freedom from MALE rate, 90%). Debris was retrieved in the SpiderFX device in 47% of patients.ConclusionsThe use of the SpiderFX EPD in the BTK circulation in patients with CLI is safe and frequently retrieves debris.  相似文献   

11.
PurposeTo investigate vascular access status before first cannulation and the clinical implications of angiography performed before cannulation.Materials and MethodsA retrospective review of 300 consecutive patients who underwent angiography after vascular access surgery and before cannulation between August 2004 and April 2010 was performed. Angiography was performed 4–6 weeks after the surgery but before the first cannulation.ResultsAngiography revealed 94 (31.3%) cases of severe stenosis (≥ 50% luminal narrowing) that required percutaneous transluminal angioplasty (PTA) or a second operation. No stenosis was observed in 122 (40.7%) cases, and mild stenosis (< 50% luminal narrowing) was observed in 84 (28%) cases. For the 94 cases with severe stenosis, PTA was performed in 66, and a second operation was performed in 16. In the other cases (n = 12), HD was maintained by a permanent catheter, or the patients were transferred to another institution. PTA was an immediate success in all patients who underwent the procedure except two. Of 84 patients with mild stenosis, 70 were followed for 1 year; vascular access dysfunction occurred in 15, and 11 of these underwent successful PTA. Of the 122 patients with normal angiographic findings, 102 were followed for 1 year, and vascular access dysfunction did not occur in any of these patients.ConclusionsEarly postoperative angiography before the first hemodialysis is helpful for the early detection and treatment of vascular access dysfunction.  相似文献   

12.
PurposeTo describe the technique, technical success, and complications of prostate fiducial marker implantation using transrectal ultrasound (US) guidance in patients undergoing image-guided radiation therapy.Materials and MethodsA retrospective review was performed of patients who underwent fiducial marker placement from January 2010–April 2013. In each case, gold markers were placed in the prostate using transrectal US guidance. Computed tomography (CT) was performed after the procedure and evaluated to confirm correct placement. Technical success, complications, and development of symptoms during radiotherapy were reviewed.ResultsTransrectal US–guided fiducial marker placement was performed on 75 patients (mean age, 62 y; range, 48–79 y) with a mean Gleason score of 7.25 (range, 6–10). Fiducial marker placement was confirmed in the intended location of the prostate or prostate bed for 297 of 300 markers (99%) on follow-up CT imaging. Two markers were placed just outside the prostate capsule, and one marker was lost. Complications included sepsis (n = 1; 1.3%), self-limiting perirectal or intraprostatic hemorrhage (n = 3; 4%), nausea (n = 1; 1.3%), transient hypotension (n = 1; 1.3%), epididymitis (n = 1; 1.3%), and urinary tract infection (n = 1; 1.3%). Complications were seen more frequently in patients with high tumor grade (P = .001) and in patients who developed metastatic disease (P = .01).ConclusionsTransrectal US–guided implantation of fiducial markers is technically feasible, is well tolerated, and has a good safety profile.  相似文献   

13.
PurposeTo analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling.Materials and MethodsA retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique.ResultsAVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism.ConclusionsA substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some “failed” AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield.  相似文献   

14.
PurposeTo assess safety, technical success, local control, and survival associated with percutaneous image-guided adrenal ablation.Materials and MethodsAdult patients with adrenal metastases who underwent percutaneous image-guided adrenal ablation during the years 2003–2012 were identified. There were 32 patients with 37 adrenal tumors identified. Technical success, safety, local control, and survival were analyzed according to standard criteria.ResultsIn 32 patients (25 men and 7 women; mean age, 66 y; age range, 44–88 y) with 37 adrenal tumors, 35 ablation procedures were performed. One patient with an 8.2-cm tumor underwent planned cryoablation debulking fully anticipating untreated margins owing to close proximity of the pancreas (ie, the intent was to diminish tumor burden rather than a curative intervention). Of the 36 patients treated with curative intent, technical success was achieved in 35 (97%) tumors. Follow-up imaging was performed on 34 of 37 tumors (excluding patients with intentional debulking [n = 1], technical failure [n = 1], and absence of follow-up [n = 1]). Local recurrence developed in 3 (8.8%) of 34 tumors. Local tumor control was achieved in 31 lesions at a mean of 22.7 months of follow-up. Recurrence-free survival and overall survival at 36 months were 88% and 52%, respectively, with a median survival of 34.5 months. A Common Terminology Criteria for Adverse Events version 4 grade 3 or 4 complication was observed in three (8.6%) ablation procedures.ConclusionsImage-guided ablation is safe and effective for local control of metastatic adrenal tumors and provides a minimally invasive alternative to surgical resection in appropriately selected patients.  相似文献   

15.
PurposeTo report the early results of use of the Endurant stent graft in the treatment of ruptured abdominal aortic aneurysms (AAAs).Materials and MethodsNine consecutive patients (seven men and two women; mean age, 76 y; range, 65–87 y) underwent endovascular aneurysm repair (EVAR) for a ruptured AAA with the Endurant stent graft between April and December 2012. EVAR was emergent in all cases. Early technical success, clinical success, major complication, and mortality rates were analyzed.ResultsIntraoperative immediate technical success was achieved in all nine patients. The 30-day clinical success rate was 67% (six of nine patients). The 30-day mortality rate was 33% (three of nine patients). During a mean follow-up of 6 months (range, 3–10 mo), none of the cases required reintervention; there was one late death attributed to probable endograft infection.ConclusionsThe short-term results of EVAR with the Endurant stent graft in patients with ruptured AAAs are encouraging.  相似文献   

16.
PurposeTo evaluate the impact of cone-beam computed tomography (CT) during sclerotherapy of low-flow vascular malformations.Materials and MethodsEighty-seven cone-beam CT examinations were acquired during 81 sclerotherapy treatments of low-flow malformations in 48 patients: 81 were performed to evaluate sclerosing agent diffusion and six were performed to evaluate needle or catheter positioning before injection of therapeutic agent. Image quality was rated by two observers. Clinical impact of cone-beam CT in the assessment of therapeutic agent diffusion, needle or catheter positioning, subsequent treatment planning, and complication detection was evaluated. The κ-statistic was used to assess interobserver reliability and proportions, with associated 95% confidence intervals (CIs).ResultsAll cone-beam CT images were successfully acquired. Image quality was rated as excellent or good for the majority of studies, with substantial interobserver reliability (κ = 0.648). Cone-beam CT studies improved assessment of therapeutic agent diffusion in 83% of cases (67 of 81; 95% CI, 75%–91%) for observer 1, who had access to ultrasound, fluoroscopic, and digital subtraction angiographic (DSA) imaging, and in 95% of cases (77 of 81; 95% CI, 90%–100%) for observer 2, who had access to only stored fluoroscopic spot radiographs and DSA images. Cone-beam CT impacted planning of the next treatment session in 49% of cases (40 of 81; 95% CI, 38%–60%). In 7% of cases (six of 81; 95% CI, 1%–13%), complications such as migration of therapeutic agent or compression of upper airways were detected that were not seen with other imaging.ConclusionsCone-beam CT can be a useful adjunctive imaging tool, providing information to help decision-making during percutaneous sclerotherapy and ongoing management of low-flow vascular malformations.  相似文献   

17.
PurposeTo evaluate combined radiofrequency (RF) ablation and percutaneous osteoplasty (POP) in patients with painful extraspinal bone metastases.Materials and MethodsIn a retrospective study, 38 patients with 54 extraspinal bone metastases (ilium, n = 24; acetabulum, n = 21; femur, n = 7; ischium, n = 1; tibia, n = 1) were treated with RF ablation and POP. All patients had pain refractory to analgesic medication with intensity > 3 on a visual analog scale (VAS). Changes in quality of life were evaluated based on pain relief (VAS score), function on a Karnofsky performance scale, and analgesic dose before and immediately after the procedure and during follow-up. VAS score was the primary outcome, and the others were secondary outcomes.ResultsTechnical success was achieved in 37 patients (97.4%). Mean VAS score declined significantly from 7.1 ± 1.5 before treatment to 2.2 ± 2.0 at 24 hours after treatment (P < .05), 1.6 ± 1.8 at 3 months after treatment (P < .05), and 1.3 ± 1.8 at 6 months after treatment (P < .05). Pain relief immediately after the procedure was reported by 35 patients (92.1%); pain regressed completely in 7 (18.4%) patients. After 6 months, narcotic analgesia had been suspended in 32 of 33 patients (97.0%). Pain was controlled by nonsteroidal antiinflammatory drugs in 8 patients (24.2%), and no analgesia was necessary in 24 patients (72.7%). Mean Karnofsky performance scale score after treatment was higher than before treatment (P < .05). The major complication rate was 2.6% (1 of 38 patients), with one case of vasovagal shock. The minor complication rate was 23.7% (9 of 38 patients).ConclusionsRF ablation with POP is effective for pain relief and functional recovery in patients with painful extraspinal bone metastases and can significantly improve quality of life.  相似文献   

18.
PurposeTo investigate the success and safety of routine versus advanced inferior vena cava (IVC) filter retrieval techniques.Materials and MethodsA retrospective review was performed of patients who underwent IVC filter placement and/or a retrieval attempt over a 10-year period. Retrieval technique(s), preretrieval computed tomography, preretrieval venography, and clinical/imaging follow-up for 30 days after retrieval were analyzed. Mean filter dwell time was 134 days (range, 0–2,475 d).ResultsFilter retrieval was attempted 231 times in 217 patients (39% female, 61% male; mean age, 50.7 y), with success rates of 73.2% (169 of 231) and 94.7% (54 of 57) for routine and advanced filter retrieval techniques, respectively. The overall filter retrieval complication rate was 1.7% (four of 231); complications in four patients (with multiple complications in some cases) included IVC dissection, IVC intussusception, IVC thrombus/stenosis, filter fracture with embedded strut, IVC injury with hemorrhage, and vascular injury from complicated venous access. The rate of complications associated with filter retrievals that required advanced technique was significantly higher than seen with routine technique (5.3% vs 0.4%; P < .05). Longer dwell time, more transverse tilt, and presence of an embedded hook were associated with significantly increased rates of failed retrieval via routine technique (P < .05).ConclusionsIVC filters can be retrieved with a high overall success rate (98.2%) and a low complication rate (1.7%) by using advanced techniques when the routine approach has failed; however, the use of advanced techniques is associated with a significantly higher complication rate.  相似文献   

19.
This report describes the authors’ first experiences with the use of the Biodesign Enterocutaneous Fistula Plug (EFP). Six patients presented with intraperitoneal abscess and associated chronic bowel fistulas. The fistulas were treated by delivering an EFP by using radiologic guidance. The EFP placement procedure was successfully performed in all patients. All fistulas were closed within 2 weeks. Fistula recurrence occurred in two patients (33%) at 9 and 12 months after the procedure. One recurrence was associated with an adverse reaction to chemotherapy. The other was associated with the silicone flange migrating out of the bowel lumen. The Biodesign EFP offers a promising new approach for the treatment of enterocutaneous fistulas.  相似文献   

20.
PurposeTo assess the safety and efficacy of transcatheter arterial embolization for lower gastrointestinal bleeding (LGIB) and to determine the prognostic factors that affect clinical outcome.Materials and MethodsAll patients diagnosed with LGIB by angiography at a single institution from April 2006 to January 2013 were included in a retrospective study. The rates of technical success, early recurrent bleeding, major complications, clinical success, and in-hospital mortality for transcatheter arterial embolization were determined. The influence of possible prognostic factors on the outcome was analyzed.ResultsA total of 112 patients were included (36 with small-bowel LGIB, 36 with colon LGIB, and 40 with rectal LGIB). N-butyl cyanoacrylate (NBCA) was the embolic agent for 84 patients (75.0%), whereas gelatin sponge pledgets (n = 20), microcoils (n = 2), polyvinyl alcohol particles with adjunctive gelatin sponge pledgets (n = 1), and blood clots (n = 1) were used in the other patients. The technical success rate was 96.4%. For the entire group, the rates of early recurrent bleeding, major complications, clinical success, and in-hospital mortality were 17.4%, 4.6%, 74.5%, and 25.0%, respectively. These were 15.2%, 4.8%, 75.3%, and 26.2%, respectively, in the NBCA group. Hematologic malignancy, immobilization status, and coagulopathy were significant prognostic factors for clinical outcomes.ConclusionsTranscatheter arterial embolization is a safe and effective treatment for LGIB. NBCA could be used as a primary embolic agent for this procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号