首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo evaluate the feasibility of image fusion (IF) of preprocedural arterial-phase computed tomography with intraprocedural fluoroscopy for roadmapping in endovascular repair of complex aortic aneurysms, and to compare this approach versus current roadmapping methods (ie, two-dimensional [2D] and three-dimensional [3D] angiography).Materials and MethodsThirty-seven consecutive patients with complex aortic aneurysms treated with endovascular techniques were retrospectively reviewed; these included aneurysms of digestive and/or renal arteries and pararenal and juxtarenal aortic aneurysms. All interventions were performed with the same angiographic system. According to the availability of different roadmapping software, patients were successively placed into three intraprocedural image guidance groups: (i) 2D angiography (n = 9), (ii) 3D rotational angiography (n = 14), and (iii) IF (n = 14). X-ray exposure (dose–area product [DAP]), injected contrast medium volume, and procedure time were recorded.ResultsPatient characteristics were similar among groups, with no statistically significant differences (P ≥ .05). There was no statistical difference in endograft deployment success between groups (2D angiography, eight of nine patients [89%]; 3D angiography and IF, 14 of 14 patients each [100%]). The IF group showed significant reduction (P < .0001) in injected contrast medium volume versus other groups (2D, 235 mL ± 145; 3D, 225 mL ± 119; IF, 65 mL ± 28). Mean DAP values showed no significant difference between groups (2D, 1,188 Gy·cm2 ± 1,067; 3D, 984 Gy·cm2 ± 581; IF, 655 Gy·cm2 ± 457; P = .18); nor did procedure times (2D, 233 min ± 123; 3D, 181 min ± 53; IF, 189 min ± 60; P = .59).ConclusionsThe use of IF-based roadmapping is a feasible technique for endovascular complex aneurysm repair associated with significant reduction of injected contrast agent volume and similar x-ray exposure and procedure time.  相似文献   

2.
PurposeTo evaluate angiographic recanalization, inflammatory reaction, and uterine damage after sheep uterine artery embolization (UAE) with a novel calibrated resorbable embolization microsphere (REM) and compare the results with control nonresorbable microspheres.Materials and MethodsSix hormonally artificially cycled sheep underwent bilateral UAE until stasis with either REM or trisacryl-gelatin microspheres (TGMS). At 7 days, control angiograms were obtained to assess the residual vascularization at arterial and parenchymal phases. The animals were then sacrificed for analysis of the presence of microspheres, inflammatory foreign body reaction, and surface areas of uterine damage.ResultsMean volume of microspheres injected per uterine artery (UA) or per animal did not differ between groups. At day 7, the flow was normal for six of six UAs that received embolization with REM versus only three of six UAs with TGMS (P = .0455, χ2 test). Uterine parenchymography showed no defects in six UAs in the REM group versus five defects in six UAs in the TGMS group (P = .0060, χ2 test). No REM or residual fragments of microspheres were observed on histologic analysis. TGMS were observed in tissues and accompanied by a mild inflammatory response. Necrosis rates were not significantly different between the two products, either in endometrium (REM 23.5% ± 28.8% [median 8.1%] vs TGMS 21.8% ± 23.7% [median 14.6%]) or in myometrium (REM 8.2% ± 22.7% [median 0.0%] vs TGMS 8.8% ± 20.8% [median 0.9%]). Endometrium alteration rate was lower with REM than with TGMS (39.7% ± 25.7% [median 34%] vs 60.6% ± 27.1% [median 71%]; P = .0060, Mann-Whitney test). Myometrium alteration rates were not significantly different between REM (45.7% ± 37.1% [median 63.0%]) and TGMS (37.8% ± 34.0% [median 19.1%]).ConclusionsAt 1 week after sheep UAE with REM, the recanalization was complete, the microspheres were completely degraded, and there was no remnant inflammatory response.  相似文献   

3.
PurposeTo determine the utility of the apparent diffusion coefficient (ADC) of uterine leiomyoma for prediction of the potential response to uterine artery embolization (UAE).Materials and MethodsThis prospective study included 49 patients with uterine leiomyomas who underwent diffusion-weighted magnetic resonance (MR) imaging before UAE between May 2011 and January 2012. All patients also underwent 3-month follow-up MR imaging after UAE. Using conventional and diffusion-weighted MR imaging sequences, 72 uterine leiomyomas ≥ 3 cm were prospectively evaluated. The volume of each leiomyoma was calculated, and quantitative measurement of ADC was performed. Regression analysis was used to evaluate the relationship between ADC and volumetric response after UAE. Receiver operating characteristic curve analysis was performed to determine the sensitivity and specificity of ADC for prediction of the potential response to UAE. Interclass correlation coefficient analysis was used to assess interobserver variability between two radiologists.ResultsVolume reduction rates of leiomyomas after UAE ranged from 0.2%–89.1% (mean, 44.1%). ADC ranged from 0.559 × 10?3 mm2/s to 1.814 × 10?3 mm2/s (mean, 1.170 × 10?3 mm2/s). ADC was statistically significantly related to volumetric response of leiomyomas (P = .014). Using a threshold of 1.092 × 10?3 mm2/s, the sensitivity and specificity of ADC for prediction of > 50% volume reduction of the leiomyoma after UAE were 82.6% and 52.3%, respectively. Using a threshold of 1.023 × 10?3 mm2/s, the sensitivity and specificity of ADC for prediction of < 30% volume reduction were 80.8% and 33.3%, respectively. The interclass correlation coefficient for measuring ADC of uterine leiomyomas between two radiologists was 0.98.ConclusionsADC of uterine leiomyomas was significantly related to the volume reduction after UAE. ADC may be useful in predicting the potential response to UAE. A high ADC of the uterine leiomyoma may be associated with a greater volume reduction after UAE.  相似文献   

4.
PurposeTo compare standard coil embolization versus the use of an antireflux microcatheter (ARM) in patients undergoing planning angiography before selective internal radiation therapy (SIRT).Materials and MethodsA prospective, single-center trial was performed in which 30 patients were randomly assigned to undergo SIRT with coil embolization or the use of an ARM. The coil group underwent detachable coil embolization of nontarget vessels, and the ARM group underwent infusion of macroaggregated albumin with use of an ARM system, without coil embolization. Single-photon emission computed tomography (CT)/CT was then performed to assess for nontarget distribution. The primary endpoint was fluoroscopy time during planning angiography. Secondary endpoints included deployment time, total procedure time, radiation dose–area product, contrast agent used, and adverse events. Endpoints were evaluated during planning angiography and SIRT.ResultsOver a 9-month period, 30 consecutive patients were randomized at a 1:1 ratio between coil embolization and ARM groups. Technical success rates were 100% in both groups. Mean fluoroscopy time was significantly reduced in the ARM group versus the coil embolization group (1.8 min [range, 0.4–4.9 min] vs 6.0 min [range, 1.9–15.7 min]; P = .002). The planning procedure time (P < .001), deployment time (P < .001), dose–area product (P = .04), and amount of contrast agent used (P < .001) were also significantly less in the ARM group than in the coil embolization group. No nontarget distribution was detected in either group. There was no difference between groups in dose delivered on the day of SIRT (P = .71). There were no major or minor adverse events at 30 days.ConclusionsThe use of an ARM during planning angiography can significantly reduce fluoroscopy time, procedure time, and radiation dose.  相似文献   

5.
PurposeTo compare the incidences of symptom recurrence and permanent amenorrhea following uterine artery embolization (UAE) for symptomatic fibroid tumors in patients with type I and II utero-ovarian anastomoses (UOAs) with versus without ovarian artery embolization (OAE).Materials and MethodsA retrospective, institutional review board–approved study of 99 women who underwent UAE for symptomatic fibroid tumors from April 2005 to October 2010 was conducted to identify patients who had type I or II UOAs at the time of UAE. Based on the embolization technique, patients were categorized into standard (ie, UAE only), combined (ie, UAE and OAE), and control (patients without UOAs who underwent UAE) groups. Data collected included patient characteristics, procedural technique and findings, symptom recurrence, secondary interventions, and permanent amenorrhea. Statistical analysis was performed with the Fisher exact test, with significance reached at P < .05.ResultsTwenty patients (20.2%; mean age, 46.9 y ± 6.3) had type I (n = 3) or II (n = 17) UOAs. Thirteen (65%) underwent UAE only (standard group) and seven (35%) underwent UAE and OAE (combined group). There were no significant differences between groups in demographics or in the incidence of permanent amenorrhea after procedures (follow-up, 561 d ± 490). There was a significantly higher incidence of symptom recurrence in the standard group compared with the control group (P = .01), with no differences between combined and control groups (P = 1).ConclusionsThere were no statistical differences in permanent amenorrhea rates in the groups studied, with significantly higher symptom recurrence rates observed when OAE was not performed in the setting of UOA.  相似文献   

6.
7.
PurposeTo measure and compare individual staff radiation dose levels during interventional radiologic (IR) procedures with and without real-time feedback to evaluate whether it has any impact on staff radiation dose.Materials and MethodsA prospective trial was performed in which individuals filling five different staff roles wore radiation dosimeters during all IR procedures during two phases: a 12-week “closed” phase (measurements recorded but display was off, so no feedback was provided) and a 17-week “open” phase (display was on and provided real-time feedback). Radiation dose rates were recorded and compared by Mann–Whitney U test.ResultsThere was no significant difference in median procedure time, fluoroscopy time, or patient dose (dose–area product normalized to fluoroscopy time) between the two phases. Overall, the median staff dose was lower in the open phase (0.56 µSv/min of fluoroscopy time) than in the closed phase (3.01 µSv/min; P < .05). The IR attending physician dose decreased significantly for procedures for which the physicians were close to the patient, but not for ones for which they were far away.ConclusionsA radiation dose monitoring system that provides real-time feedback to the interventional staff can significantly reduce radiation exposure to the primary operator, most likely by increasing staff compliance with use of radiation protection equipment and dose reduction techniques.  相似文献   

8.
PurposeTo assess the feasibility of time-resolved magnetic resonance (MR) angiography as a follow-up method after embolization for pulmonary arteriovenous malformations (PAVMs).Materials and MethodsEvaluation of 28 PAVMs in 10 patients previously treated with embolization with platinum coils was performed. The mean observation period after embolization was 49 months. All patients underwent unenhanced chest computed tomography (CT) and time-resolved MR angiography followed by transcatheter digital subtraction angiography within 5 weeks for a definite diagnosis. Two radiologists reviewed the CT and time-resolved MR angiography findings using a blinded method. On CT, the draining veins of the PAVMs were measured before and after embolization, and shrinkage rates were calculated. On time-resolved MR angiography, recanalization was diagnosed when the draining vein or aneurysmal sac or both were enhanced in the pulmonary arterial phase. Correlations between recanalization, the shrinkage rate of the draining vein, and the diagnostic accuracies of CT and time-resolved MR angiography were assessed and compared with digital subtraction angiography.ResultsFive lesions could not be measured on CT because of metallic artifacts. The mean shrinkage rates of the draining vein for recanalized and occluded PAVMs were 23% ± 19 (SD) for recanalized PAVMs and 47% ± 21 for occluded PAVMs (P = .001). The sensitivity and specificity were 93% and 53%, respectively, when the shrinkage rate threshold was set to 50%. On time-resolved MR angiography, the sensitivity and specificity were 93% and 100%, respectively, for Reader 1 and 100% and 93%, respectively, for Reader 2. The κ coefficient was 0.86.ConclusionsTime-resolved MR angiography appears to be a feasible method for PAVM follow-up examinations and to provide a more accurate diagnosis of recanalization compared with unenhanced CT.  相似文献   

9.
PurposeTo describe the transvenous application of intracardiac echocardiography (ICE) for guidance during endovascular aortic repair (EVAR).Materials and MethodsEight patients with an infrarenal abdominal aortic aneurysm (AAA) and chronic renal failure were determined suitable for EVAR. The procedure was performed by deploying the transcaval and transiliac vein guidance of an ICE catheter to reduce the dosage of iodinated contrast medium. Multiple guidance parameters were assessed. The present study describes the EVAR procedure and postprocedure transabdominal ultrasound (US) follow-up results at 3–4 months.ResultsThe eight procedures were completed by using transvenous ICE guidance. No contrast medium was used in five patients, and 3–20 mL of isoosmolar contrast medium was administered in the other three. No endoleaks were detected by ICE immediately after stent deployment. One patient who had a single functioning kidney developed renal failure that was attributed to manipulation-related cholesterol embolization. That patient became dependent on dialysis and died 3.5 months after the procedure. No endoleaks were detected at 3–4-month US follow-up in the other seven patients.ConclusionsTransvenous ICE guidance is a promising method to reduce the dosage of iodinated contrast medium in patients with renal dysfunction undergoing EVAR. A prospective trial comparing this modality versus digital subtraction angiography guidance with iodinated contrast medium in terms of safety, accuracy, and long-term efficacy is recommended.  相似文献   

10.
PurposeTo evaluate whether uterine artery embolization (UAE) can reduce the premenstrual symptoms in women undergoing UAE for fibroid tumors or adenomyosis.Materials and MethodsAmong 141 women who underwent UAE for symptomatic fibroid tumors or adenomyosis at a single institution between March 2011 and February 2013, 54 premenstrual symptoms in 39 patients were prospectively analyzed. Premenstrual symptoms were rated by the patient on a scale of 0 to 10, with 0 representing no symptom and 10 representing the baseline severity. The change in premenstrual symptom score was calculated by subtracting the baseline score from the post-UAE score. At 3–6 months after UAE, each woman also completed a symptom severity questionnaire to assess the severity of menstrual bleeding to compare the changes in premenstrual symptoms scores between women with and without menorrhagia.ResultsBack pain, headache, and gastrointestinal symptoms (eg, constipation, indigestion, lower abdominal pain) were significantly improved after UAE (P < .05). Muscle pain, fatigue, nervousness, breast tenderness, and systemic edema were also improved, but not significantly so. The mean premenstrual symptom score change in patients with menorrhagia was significantly greater than in those without menorrhagia (−6.4 vs −3.7; P = .044).There was no correlation between the degree of menorrhagia score change and the degree of premenstrual symptom score change (P = .186).ConclusionsUAE could be a method to alleviate some premenstrual symptoms in patients with uterine fibroid tumors or adenomyosis.  相似文献   

11.
PurposeTo evaluate the prevalence of inferior mesenteric artery (IMA) collaterals to the uterus found during uterine artery embolization (UAE), associated risk factors, and clinical outcomes.Materials and MethodsThe records of 559 women who underwent UAE during the period 2008–2011 for uterine fibroids or adenomyosis found on magnetic resonance imaging were retrospectively analyzed. If IMA collaterals to the uterus were suspected on aortography performed after embolization, selective angiography was performed. Risk factors for IMA collaterals to the uterus were analyzed, including the presence of adenomyosis, baseline uterine volume, or prior pelvic surgery.ResultsCollaterals to the uterus were found from the ovarian artery (n = 21; 3.8%), IMA (n = 7; 1.3%), round ligament artery (n = 1; 0.2%), and internal pudendal artery (n = 1; 0.2%). IMA collaterals were found in seven patients. Of 185 patients, 6 (3.2%) had adenomyosis, with or without fibroids, which was significantly more frequent than the 1 (0.27%) of 374 patients who had fibroids only (P = .006). On multiple logistic regression analysis, the presence of adenomyosis (odds ratio, 19.556; P = .0168) and uterine volume (odds ratio, 1.003; P = .0069) were independent factors for the presence of IMA collaterals. Of the seven patients with IMA collaterals, embolization was not attempted in six, resulting in clinical failure in four. One patient who underwent IMA embolization with coils experienced clinical improvement.ConclusionsThe IMA was the second most common (1.3%) source of collaterals to the uterus. IMA collaterals were more frequent in patients with adenomyosis than in patients with fibroids only, resulting in high frequency of treatment failure.  相似文献   

12.
PurposeTo investigate vascular access status before first cannulation and the clinical implications of angiography performed before cannulation.Materials and MethodsA retrospective review of 300 consecutive patients who underwent angiography after vascular access surgery and before cannulation between August 2004 and April 2010 was performed. Angiography was performed 4–6 weeks after the surgery but before the first cannulation.ResultsAngiography revealed 94 (31.3%) cases of severe stenosis (≥ 50% luminal narrowing) that required percutaneous transluminal angioplasty (PTA) or a second operation. No stenosis was observed in 122 (40.7%) cases, and mild stenosis (< 50% luminal narrowing) was observed in 84 (28%) cases. For the 94 cases with severe stenosis, PTA was performed in 66, and a second operation was performed in 16. In the other cases (n = 12), HD was maintained by a permanent catheter, or the patients were transferred to another institution. PTA was an immediate success in all patients who underwent the procedure except two. Of 84 patients with mild stenosis, 70 were followed for 1 year; vascular access dysfunction occurred in 15, and 11 of these underwent successful PTA. Of the 122 patients with normal angiographic findings, 102 were followed for 1 year, and vascular access dysfunction did not occur in any of these patients.ConclusionsEarly postoperative angiography before the first hemodialysis is helpful for the early detection and treatment of vascular access dysfunction.  相似文献   

13.
PurposeTo prospectively determine the feasibility of flat-detector (FD) computed tomography (CT) perfusion to measure hepatic blood volume (BV) in the angiography suite in patients with hepatocellular carcinoma (HCC).Materials and MethodsTwenty patients with HCC were investigated with conventional multislice and FD CT perfusion. CT perfusion was carried out on a multislice CT scanner, and FD CT perfusion was performed on a C-arm angiographic system, before transarterial chemoembolization procedures. BV values of conventional and FD CT perfusion were measured within tumors and liver parenchyma. The arterial perfusion portion of CT perfusion BV was extracted from CT perfusion BV by multiplying it by a hepatic perfusion index. Relative values (RVs) for CT perfusion arterial BV and FD CT perfusion BV (FD BV) were defined by dividing BV of tumor by BV of parenchyma. Relationships between BV and RV values of these two techniques were analyzed.ResultsIn all patients, both perfusion procedures were technically successful, and all 33 HCCs larger than 10 mm were identified with both imaging methods. There were strong correlations between the absolute values of FD BV and CT perfusion arterial BV (tumor, r = 0.903; parenchyma, r = 0.920; both P < .001). Bland–Altman analysis showed a mean difference of −0.15 ± 0.24 between RVs for CT perfusion arterial BV and FD BV.ConclusionsThe feasibility of FD CT perfusion to assess BV values of liver tumor and surrounding parenchyma in the angiographic suite was demonstrated.  相似文献   

14.
PurposeTo prospectively evaluate the incidence of pulmonary cement embolism (PCE) after vertebroplasty in procedures performed under real-time computed tomographic (CT) fluoroscopy guidance.Materials and MethodsA total of 85 vertebroplasties were performed in 51 consecutive patients (31 women, 20 men; mean age, 71.9 y; range, 48–92 y) in 51 sessions. The needle was inserted with guidance from intermittent single-shot CT scans, and intermittent CT fluoroscopy was used during cement injection only. To reduce the risk of extravertebral or extraosseous leakage, several procedures (cement injection stopping/slowing, needle position changes) were employed. The chest and treated bone were scanned immediately after vertebroplasty. These CT images included the entire thorax as well as the treated vertebrae.ResultsNo cement emboli were observed on CT after vertebroplasty. After 85 vertebroplasty procedures, 44 extravertebral leaks were detected. Epidural leaks were observed on CT in six treated vertebrae (7%), in 12 cases in the anterior external venous plexus (14.1%), in five in the azygos vein (5.8%), in 19 in the disc space (22%), and in two in the foraminal space (2.3%). On a per-patient basis, the odds of leaks increased with the number of vertebroplasties (P = .05) and the volume of cement used (P = .0412). There was also a higher probability of leak (P < .05) for osteoporotic vertebral compression fractures (67.9%; 95% confidence interval, 47.7%–84.1%) than osteolytic spinal metastases (34.8%; 16.4%–57.3%).ConclusionsPCE did not occur after vertebroplasty under CT fluoroscopy guidance. Further larger prospective vertebroplasty studies are needed to compare the rates of PCE for CT versus conventional fluoroscopic guidance.  相似文献   

15.
PurposeTo investigate the feasibility of yttrium-90 (90Y) glass microsphere radioembolization (including angiography, lung shunt assessment, and treatment) as a single-session, outpatient procedure.Materials and MethodsBetween January 2008 and June 2013, 14 patients underwent outpatient, single-session radioembolization with 90Y glass microspheres. As part of the routine diagnostic work-up, all patients underwent either computed tomography (CT) or magnetic resonance imaging of the liver with three-dimensional analysis and had laboratory results forwarded to our center for confirmation of candidacy before treatment. On treatment day, all patients underwent planning mesenteric angiography with flat panel cone-beam CT imaging. Patients were administered 33–85 MBq of technetium-99m macroaggregated albumin (99mTc-MAA) via a microcatheter positioned in a hepatic artery supplying the tumor of interest. Planar scintigraphy was initiated within 2 hours after the administration of 99mTc-MAA and lung shunt fraction was determined. Final dosimetry calculations were performed while the patient was being transferred back from nuclear medicine to interventional radiology.ResultsAll patients successfully underwent planning angiography with administration of 99mTc-MAA and 90Y radioembolization as a single-session treatment. There were no reportable or recordable medical events; treatment was carried out to the desired dose in all cases. The mean total procedure time was 2.70 hours ± 0.72 (range, 1.63–3.97 h).ConclusionsThis study reports a novel proof of concept for performing radioembolization in a single-session setting. By using the described method, time between initial clinical assessments and radioembolization treatment is decreased, and costs are minimized.  相似文献   

16.
PurposeTo evaluate the feasibility of combining transcatheter computed tomography (CT) arterial portography or transcatheter CT hepatic arteriography with percutaneous liver ablation for optimized and repeated tumor exposure.Materials and MethodsStudy participants were 20 patients (13 men and 7 women; mean age, 59.4 y; range, 40–76 y) with unresectable liver-only malignancies—14 with colorectal liver metastases (29 lesions), 5 with hepatocellular carcinoma (7 lesions), and 1 with intrahepatic cholangiocarcinoma (2 lesions)—that were obscure on nonenhanced CT. A catheter was placed within the superior mesenteric artery (CT arterial portography) or in the hepatic artery (CT hepatic arteriography). CT arterial portography or CT hepatic arteriography was repeatedly performed after injecting 30–60 mL 1:2 diluted contrast material to plan, guide, and evaluate ablation. The operator confidence levels and the liver-to-lesion attenuation differences were assessed as well as needle-to-target mismatch distance, technical success, and technique effectiveness after 3 months.ResultsTechnical success rate was 100%; there were no major complications. Compared with conventional unenhanced CT, operator confidence increased significantly for CT arterial portography or CT hepatic arteriography cases (P < .001). The liver-to-lesion attenuation differences between unenhanced CT, contrast-enhanced CT, and CT arterial portography or CT hepatic arteriography were statistically significant (mean attenuation difference, 5 HU vs 28 HU vs 70 HU; P < .001). Mean needle-to-target mismatch distance was 2.4 mm ± 1.2 (range, 0–12.0 mm). Primary technique effectiveness at 3 months was 87% (33 of 38 lesions).ConclusionsIn patients with technically unresectable liver-only malignancies, single-session CT arterial portography–guided or CT hepatic arteriography–guided percutaneous tumor ablation enables repeated contrast-enhanced imaging and real-time contrast-enhanced CT fluoroscopy and improves lesion conspicuity.  相似文献   

17.
PurposeTo assess long-term outcomes of magnetic resonance (MR)–guided focused ultrasound (US) treatments of uterine fibroids.Materials and MethodsA retrospective follow-up of 138 patients treated at a single institution between March 2005 and November 2011 was conducted. The patients were not part of a clinical study and were followed through retrospective review of their medical records and telephone interviews to assess additional treatments for fibroid-related symptoms. Survival methods, including Cox proportional hazards models, were used to assess the association between incidence of additional treatments and patient data obtained during screening before treatment.ResultsThe average length of follow-up was 2.8 years (range, 1–7.2 y). The cumulative incidence of additional treatments at 36 months and 48 months after MR-guided focused US was 19% and 23%, respectively. Women who did not need additional treatment were older than women who did (46.3 y ± 5.6 vs 43.0 y ± 5.8; P = .006; hazard ratio, 0.855; 95% confidence interval, 0.789–0.925). Additionally, women with heterogeneous or bright fibroids on T2-weighted MR imaging were more likely to require additional treatment compared with women with homogeneously dark fibroids (hazard ratio, 5.185 or 5.937, respectively; 95% confidence interval, 1.845–14.569 or 1.401–25.166, respectively). Physician predictions of treatment success, recorded during the screening process, had significant predictive value (P = .018).ConclusionsThe long-term rates of additional interventions after MR-guided focused US of symptomatic uterine fibroids were found to be comparable with other uterine-sparing procedures, such as uterine artery embolization or myomectomy. Older patient age and homogeneously dark fibroids were associated with fewer additional treatments. Physician assessment of treatment success was found to be a valuable tool in patient screening.  相似文献   

18.
PurposeTo assess the feasibility and diagnostic performance of dynamic volumetric computed tomography (CT) angiography with large-area detectors in the detection and classification of endoleaks after endovascular aneurysm repair (EVAR).Materials and MethodsLow-dose dynamic volumetric CT angiography performed with the patient in Fowler position was used to scan the entire stent graft with a 16-cm-area detector during the first follow-up examination after EVAR. There were 39 consecutive patients (36 men and 3 women; mean age, 74 y ± 8.7) examined with approximately 14–20 intermittent scans (temporal resolution, 2 s; scan range, 160 mm). The effective radiation dose, image quality, interobserver and intraobserver agreement for endoleak detection, and time delay between peak enhancement of the aorta and endoleaks were evaluated.ResultsAll examinations with the patient in Fowler position enabled the entire stent graft to be scanned and were rated as diagnostic. The mean effective radiation dose was 13.1 mSv. Endoleaks were detected in eight patients (type Ia, n = 1; type II, n = 6; type III, n = 1). Interobserver agreement (κ = 0.794) and intraobserver agreement (κ = 1.00) for detection of endoleaks were excellent. The mean time delay between peak enhancement of the aorta and the endoleaks was significantly less for type I/III endoleaks (2.0 s ± 0) compared with type II endoleaks (5.3 s ± 1.0; P < .001).ConclusionsLow-dose dynamic volumetric CT angiography performed with the patient in Fowler position is feasible after EVAR. Dynamic information, including cine imaging, the timing of peak enhancement, and the Hounsfield units index, is useful in detecting and classifying endoleaks.  相似文献   

19.
PurposeTo evaluate the efficacy of microwave ablation for osteoid osteomas by using dynamic contrast-enhanced magnetic resonance (MR) imaging in early treatment assessment.Materials and MethodsTen patients (two female, eight male; mean age, 28 y; range, 16–47 y) presenting with osteoid osteomas were treated between June 2010 and December 2012 with the use of computed tomography (CT)–guided microwave ablation. Osteoid osteomas were found at the femoral neck (n = 4), tibia (n = 3), calcaneus (n = 1), navicular bone (n = 1), and dorsal rib (n = 1). Dynamic contrast-enhanced MR imaging at 3.0 T was performed 1 day before microwave ablation and again after ablation. The procedure was considered successful if the signal intensity (SI) of the lesion on MR imaging decreased by at least 50% and the patient was pain-free within 1 week of intervention.ResultsAll patients were pain-free within 1 week after microwave ablation and remained so during the 6 months of follow-up. No major or minor complications developed. On average, SI of the lesions decreased by 75% (range, 55.5%–89.1%) after treatment. The difference in lesion SI before versus after ablation was significant by t test (P < .0001; confidence interval, 120.26–174.96) and Wilcoxon test (P = .0020).ConclusionsMicrowave ablation treatment of osteoid osteoma was highly successful, without any complications observed. Dynamic contrast-enhanced MR imaging is a useful tool for diagnosing osteoid osteoma and evaluating treatment.  相似文献   

20.
PurposeTo describe an artifact that mimics thrombosis when assessing abdominal vasculature on magnetic resonance (MR) imaging using ferumoxytol in patients with contraindications to gadolinium-based contrast agents and to evaluate factors that may contribute to this artifact.Materials and MethodsThree radiologists in consensus retrospectively evaluated 61 abdominal MR imaging examinations using ferumoxytol as an intravenous contrast agent for the presence of an observed artifact that can mimic thrombosis. Patient demographics and contrast agent bolus concentrations were compared with an unpaired Wilcoxon signed rank test.ResultsAn artifact mimicking thrombosis was observed in 30 of 61 examinations, all on the arterial phase sequences. In examinations with this artifact, the average concentration of administered ferumoxytol was greater than in examinations where the artifact was not observed (P < .01). Several additional vascular findings were observed, including portal vein thrombosis (n = 2) and aneurysm (n = 1), renal vein thrombosis (n = 2), abdominal aortic aneurysm (n = 1), abdominal and iliac artery dissection (n = 3), and sequelae of portal hypertension (n = 8).ConclusionsAlthough MR imaging using ferumoxytol as an intravenous contrast agent can be useful in detecting abdominal vascular abnormalities, an artifact mimicking vascular thrombosis was observed in nearly half of the examinations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号