首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
RapiDEC Staph is a test for presumptive identification of the principal human staphylococcal species, Staphylococcus aureus, S. epidermidis, and S. saprophyticus. The test includes control and test cupules for fluorogenic detection of coagulase and chromogenic substrates for alkaline phosphatase and beta-galactosidase. These tests identify S. aureus, S. epidermidis, and S. saprophyticus, respectively. Positive results with both chromogenic substrates provide a presumptive identification of S. xylosus or S. intermedius (S. xylosus-S. intermedius). Test cupules are inoculated with an organism suspension, and reactions are read after a 2-h incubation. RapiDEC-Staph was evaluated with 303 clinical and stock staphylococcal strains. Identifications were compared with those obtained by the tube coagulase test, a latex slide coagulase test (StaphAUREX), another commercial identification system (Staph-TRAC), and additional conventional tests. RapiDEC-Staph correctly identified 100% of 130 S. aureus strains, 70.3% of 74 S. epidermidis strains, and 81.3% of 32 S. saprophyticus strains. Four of five S. xylosus isolates were called S. xylosus-S. intermedius. Unidentified S. epidermidis and S. saprophyticus strains were called "Staphylococcus spp." Among the 62 other coagulase-negative staphylococci, 4 were misidentified as S. epidermidis and 7 were misidentified as S. saprophyticus. While the sensitivity and specificity of the fluorogenic coagulase test for S. aureus were 100%, failure to detect alkaline phosphatase activity in several S. epidermidis isolates resulted in fewer correct identifications by the RapiDEC-Staph test for this species.  相似文献   

2.
Six commercial agglutination tests designed for the identification of Staphylococcus aureus were compared by using a strain collection which included 512 staphylococci representing 33 species (318 isolates of Staphylococcus aureus [including 144 oxacillin resistant], 46 S. epidermidis isolates, 15 S. haemolyticus isolates, 12 S. saprophyticus isolates, 29 S. schleiferi isolates, 30 S. lugdunensis isolates, and 62 other coagulase-negative staphylococci). This group also included a proportion of strains with unusual phenotypes (e.g., 19 coagulase-negative S. aureus isolates, 26 clumping factor-negative S. aureus isolates, and 4 S. aureus isolates each with a double deficiency). The overall sensitivity for identification of typical and atypical S. aureus was high with the Staphaurex Plus test (Murex Biotech) (99.7%), the Pastorex Staph Plus test (Sanofi Diagnostics Pasteur) (99.7%), and the Slidex Staph Plus test (bioMérieux) (100%). The overall rate of specificity was affected by the unusual inclusion in this study of a high proportion of non-S. aureus species, such as S. lugdunensis and S. schleiferi, which express a clumping factor and therefore produce a positive result with the agglutination tests.  相似文献   

3.
Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compared with the conventional slide coagulase, tube coagulase (TC), and thermonuclease (TNase) tests for the identification of Staphylococcus aureus. A total of 118 clinical isolates of S. aureus (52 methicillin resistant), 50 S. epidermidis, 5 S. capitis, 2 S. hominis, 3 S. simulans, 6 S. saprophyticus, and 2 S. warneri were tested. The slide coagulase, TC and TNase tests detected 115 (97.5%), 117 (99.2%), and 118 (100%) of the S. aureus isolates, respectively. All showed 100% specificity. The StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph assays correctly identified 117 (99.2%), 117 (99.2%), 116 (98.3%), 110 (93.2%), 108 (91.5%), and 107 (90.7%) of the S. aureus isolates, respectively. For methicillin-resistant S. aureus isolates, StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph showed 1 (2%), 1 (2%), 2 (4%), 7 (13.5%), 7 (13.5%), and 8 (15.4%) false-negative results, respectively. All the commercial agglutination assays demonstrated false-positive results with strains of S. capitis, S. saprophyticus and S. warneri. The overall accuracy of the commercial agglutination assays compared with TC and TNase ranged from 90.7 to 99.2%. We recommend that negative reactions with the rapid commercial test kits for methicillin-resistant Staphylococcus isolates be confirmed with the TC or TNase test.  相似文献   

4.
A latex slide agglutination test detecting clumping factor and protein A simultaneously is recommended for rapid and reliable routine identification of Staphylococcus aureus. Strains (836) of staphylococci isolated from clinical specimens were examined, all S. aureus strains identified by conventional methods were correctly differentiated by the latex test, and no false-positive results occurred with other staphylococci. The reagent is easy to prepare since plasma is the coating material.  相似文献   

5.
Four commercially available rapid agglutination tests for the identification of Staphylococcus aureus were compared with the tube coagulase test for the identification of 300 methicillin-resistant isolates of staphylococci. Isolates tested included 207 methicillin-resistant S. aureus and 93 coagulase-negative staphylococci, collected from five medical centers. Strain variability was documented by phage typing and antimicrobial susceptibility patterns. Results of rapid identification tests ranged between 82 and 86% sensitivity, significantly poorer than the 98% sensitivity which the tube coagulase test provided.  相似文献   

6.
Three commercially available rapid slide agglutination tests for the identification of Staphylococcus aureus were evaluated with 354 recent clinical isolates (165 strains of S. aureus). The test results of two latex agglutination products, SeroSTAT Staph (Scott Laboratories, Inc.) and Staphylatex (American Micro Scan), and one hemagglutination product, Staphyloslide (BBL Microbiology Systems), were compared with the results of the tube coagulase test, which was read at 4 h (4-h tube coagulase test) and, if negative, again after overnight incubation at room temperature (24-h tube coagulase test). Discrepancies between agglutination and tube coagulase identifications were resolved by use of the thermonuclease, mannitol fermentation, and slide coagulase tests. All sensitivities, specificities, predictive values of a positive result, and predictive values of a negative result for the three agglutination tests were at least 98.8% and comparable with the 4-h tube coagulase test. Best results were obtained with the 24-h tube coagulase test, which yielded one false-negative and no false-positive tests. Agglutination identifications may be performed on organisms taken directly from a primary plate when sufficient growth is present. Kit agglutination procedures yield rapid and reliable identifications and are easy to perform. This study also demonstrates the usefulness of the 24-h tube coagulase test.  相似文献   

7.
A new latex agglutination test (Pastorex Staph-Plus, Sanofi Diagnostics Pasteur), consisting of a mixture of latex particles coated with fibrinogen and immunoglobulin G for the detection of clumping factor and protein A and latex particles sensitized with monoclonal antibodies directed to Staphylococcus aureus serotype 5 and 8 capsular polysaccharides, was compared with three commercially available rapid agglutination methods for the identification of 220 isolates of S. aureus (61 oxacillin resistant) and 128 isolates of coagulase-negative staphylococci. The sensitivity for identification of S. aureus was high with the Pastorex Staph-Plus test (98.6%) compared with those of the other tests, which ranged from 91.8 to 84.5%. Test sensitivities for the identification of oxacillin-resistant S. aureus were as follows: Pastorex Staph-Plus, 95.1%; Pastorex Staph, 73.8%; Staphyslide, 72.1%; and StaphAurex, 49.2%.  相似文献   

8.
A new commercial yellow latex agglutination reagent (Bacto-Staph) was compared with the slide and tube coagulase tests and three other commercial reagents for the identification of 283 Staphylococcus aureus and 54 non-S. aureus staphylococcal strains. Test sensitivities for the identification of S. aureus were as follows: tube coagulase, 99.6%; slide coagulase, 98.6%; Bacto-Staph, 99.6%; Staphylatex, 98.6%; Sero STAT Staph, 98.2%; and Staphyloslide, 97.5%. No false-positive reactions were observed with any of the commercial reagents.  相似文献   

9.
The speciation of methicillin-resistant Staphylococcus aureus (MRSA) poses a significant diagnostic problem when rapid identification methods such as slide agglutination tests, are used, because of the high proportion of false-negative reactions. 150 perfectly identified MRSA strains were tested on 5 commonly used agglutination reagents ("Bacto staph latex test", "Monostaph", "Pastorex staph", "Staphaurex", and "Staphyslide test") in comparison with a new micromethod ("RAPIDEC staph") which detects a type of staphylocoagulase within 2 hours by a fluorescence test. The "RAPIDEC staph" reagent enabled identification of all the MRSA while the agglutination tests gave poorer results: "Monostaph" correctly identified 64.6% of strains, "Staphyslide", 59.3%, "Bacto staph latex test", 44.6%, "Pastorex staph", 38.6% and "Staphaurex", 28.6%. These results show that agglutination slide tests are not reliable enough for the identification of MRSA which are more and more encountered in hospital wards. The authors recommend not to use slide agglutination methods. They suggest the tube test for coagulase which is the reference technique, although it is time-consuming and not well standardized. The results of this evaluation encourage the use of the "RAPIDEC staph" reagent since it is an easy-to-use, reliable technique for the rapid identification of Staphylococcus aureus.  相似文献   

10.
Comparison of rapid identification assays for Staphylococcus aureus.   总被引:1,自引:15,他引:1       下载免费PDF全文
A total of 137 strains of Staphylococcus species were blindly tested by four rapid serological assays, and the results were compared with those of the tube coagulase assay. For the S. aureus isolates, the Sero-STAT Staph assay gave six false-negative results, four of which were for methicillin-resistant strains. The Accu -Staph, Staphylatex , and Staphyloslide assays identified all the coagulase-positive strains as Staphylococcus aureus. Among the coagulase-negative staphylococci, false-positive results were seen with strains of S. capitis. S. saprophyticus, and S. cohnii. The overall accuracy of the kits compared with the tube coagulase test ranged from 95.1 to 100%.  相似文献   

11.
Staphylococcus aureus is responsible for septicaemia and serious nosocomial infections. A rapid and specific identification of this species is of great importance in clinical microbiology. Current methods for S. aureus identification require a 18 to 24 h-incubation. We describe a two hour-identification method based on the detection of the staphylocoagulase, using human prothrombin and a chromogenic substrate. 242 staphylococcal strains (160 S. aureus, 82 coagulase-negative staphylococci (CNS)) were collected from 4 French hospitals. They have been identified by the following methods: (i) clotting of citrated rabbit plasma, which is considered as reference method; (ii) biochemical tests (Rapidec Staph and Api Staph or ID 32 Staph); (iii) and agglutination test (Pastorex Staph or Pastorex Staph-plus). A strain of S. intermedius was provided by the Collection of the Pasteur Institute (Paris). An adapted culture medium is inoculated with staphylococci and adjusted to 2 Mac Farland unities. This medium is then mixed to an equal volume with a human prothrombin solution and the chromogenic substrate. After 1 to 2 hours incubation at 37 degrees C, the strength of the yellow colour of the mixture is observed to the naked eye, or measured at 405 nm with a spectrophotometer. Fifteen chromogenic tripeptides having a thrombin-like affinity and paranitroanilin as leaving group were compared. With the substrate which has the higher hydrolysis velocity and enzymatic affinity (SQ149), all S. aureus strains gave a positive result: 94.7% of the methicillin-susceptible S. aureus were detected after 1 hour incubation, but only 52.3% of the methicillin-resistant S. aureus. 98.4% of the methicillin-resistant S. aureus were detected after 2 hours. No false positive result was observed for the 82 CNS strains. The chromogenic method shows good within-run and day-to-day precision tests. It doesn't need any complementary test. The sensitivity and the specificity are 99.4% and 100% respectively.  相似文献   

12.
This paper describes a new chromogenic plate medium, CHROMagar Staph aureus (CHROMagar, Paris, France), for the identification of Staphylococcus aureus on the basis of colony pigmentation. The abilities of CHROMagar Staph aureus, thermostable nuclease (DNase), and mannitol salt agar (MSA) to identify S. aureus isolates (n = 114) and discriminate between S. aureus and coagulase-negative staphylococci (CoNS; n = 22) were compared. CHROMagar Staph aureus proved to be more sensitive and specific than DNase and MSA, allowing a reliable, simple, and rapid method for the identification of S. aureus isolates. All CoNS encountered in this study with the exception of S. chromogenes could be easily differentiated from S. aureus on this medium. The supplementation with 4 microgram of oxacillin or methicillin per ml allowed simple identification of methicillin resistance in hospital-acquired S. aureus strains which show multiple-drug resistance profiles. Community-acquired methicillin-resistant S. aureus strains showing non-multi-drug resistance profiles require further evaluation on this new chromogenic medium. Methicillin or oxacillin resistance of all S. aureus isolates was confirmed by the detection of penicillin-binding protein 2a, encoded by the mecA gene, using the latex slide agglutination MRSA-Screen test (PBP 2' Test, DR900M; Oxoid).  相似文献   

13.
Many of the commercial slide agglutination tests for Staphylococcus aureus incorporate antibodies against cell surface antigens associated with methicillin resistance, including capsular polysaccharides and an uncharacterized antigen, serotype 18. These tests are more sensitive than the first-generation agglutination procedures that detected only bound coagulase and protein A, but they suffer from false-positive reactions with some coagulase-negative staphylococci. The aim of this study was to elucidate the mechanism for false-positive agglutination by S. epidermidis in these tests. A group of methicillin-resistant S. aureus (MRSA) isolates, including a serotype 18 strain, that were not detectable in the first-generation tests were found to be of capsular polysaccharide type 8. All of these isolates were deficient in bound coagulase and/or protein A, and they possessed a heat-stable, proteinaceous antigen that was absent from a prototype capsule type 8 strain. Enzyme-linked immunosorbent assay and agarose gel immunodiffusion experiments demonstrated that this proteinaceous antigen was also present on both methicillin-sensitive and methicillin-resistant S. epidermidis clinical isolates. S. epidermidis strains that gave false-positive agglutination test results had a considerably higher level of this antigen than strains that gave the correct negative result. These findings reveal the importance of the careful selection of MRSA strains for raising anti-capsular type 8 antibodies for use in agglutination tests. Strains devoid of the antigen shared with S. epidermidis should be used to eliminate potential cross-reactions with this coagulase-negative coccus.  相似文献   

14.
A new, commercially available latex agglutination test (SeroSTAT Staph; Scott Laboratories, Inc., Fiskeville, R.I.) was compared with the tube coagulase and slide coagulase tests as means for identifying Staphylococcus aureus. Of 160 clinical isolates of S. aureus, 159 (99.4%) yielded positive results with the latex agglutination test. Negative latex agglutination test results were obtained with 266 of 267 clinical isolates of Micrococcus spp. and staphylococcal species other than S. aureus (99.6%). The latex agglutination test was found to be a rapid, technically nondemanding method for identifying S. aureus. It was as accurate as the tube coagulase test and more accurate than the slide coagulase test.  相似文献   

15.
This study evaluated the reliability of the latex slide agglutination test for identifying Staphylococcus aureus. A total of 806 clinical isolates of staphylococci were tested for latex agglutination, clumping factor, and free coagulase. Positive latex tests occurred in 98.3% of coagulase-positive strains, whereas 99.6% of coagulase-negative strains gave negative latex tests. It is concluded that in most instances, the latex slide agglutination test is a reliable method for identifying S. aureus in the clinical laboratory.  相似文献   

16.
Attachment of microorganisms to host tissue is regarded as an important step in the pathogenesis of infections. Staphylococcus saprophyticus adheres to various epithelial cells and hemagglutinates sheep erythrocytes. The hemagglutinin has been identified, but a human target for this surface protein is still not known. In our report, we show that hemagglutinating strains of S. saprophyticus bind to immobilized fibronectin, whereas nonhemagglutinating strains do not. Bacterial binding was inhibited by antibody to the hemagglutinin but not by antibody to Ssp, another surface protein of S. saprophyticus. The purified hemagglutinin but not other surface proteins bound biotin-labeled fibronectin. Binding was saturable and could be inhibited by unbound hemagglutinin, unlabeled fibronectin, and by antibody to the hemagglutinin. We thus conclude that the hemagglutinin of S. saprophyticus may act as a fibronectin receptor in the human host. Heparin, the D3 peptide, or Arg-Gly-Asp-Ser (RGDS) containing peptides did not inhibit binding of fibronectin to the hemagglutinin, indicating that the binding site is different from that of Staphylococcus aureus or Treponema pallidum.  相似文献   

17.
Four commercially available slide agglutination systems for identifying Staphylococcus aureus were compared with the conventional slide (clumping factor) and tube coagulase tests. The systems evaluated included Bacto Staph Latex (Difco Laboratories, Detroit, Mich.), Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.), Mini ID Accu-Staph (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.), and Staphaurex (Wellcome Diagnostics, Research Triangle Park, N.C.). A total of 338 clinical isolates, including methicillin-resistant S. aureus (n = 149), methicillin-susceptible S. aureus (n = 78), methicillin-resistant, coagulase-negative staphylococci (n = 45), and methicillin-susceptible, coagulase-negative staphylococci (n = 66), were tested by each method. The slide test for clumping factor, the 4-h tube coagulase test, Bacto Staph Latex, Staphyloslide, Mini ID Accu-Staph, and Staphaurex detected 212 (93.4%), 218 (96%), 223 (98.2%), 223 (98.2%), 221 (97.4%), and 224 (98.7%) of the S. aureus (44% methicillin-resistant) isolates, respectively. There were no false-positive results with any of the methods when the 111 strains of coagulase-negative staphylococci were tested. The results of this evaluation suggest that the four slide identification methods tested can provide rapid and accurate identification of methicillin-resistant S. aureus strains.  相似文献   

18.
A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aureus. A total of 380 clinical strains of staphylococci were tested. The TC test performed at room temperature yielded the largest number of TC-positive results (n = 239), and based on this observation 239 organisms were classified as S. aureus and 141 were classified as non-S. aureus. The SC, TC (37 degrees C), SeroSTAT Staph, Staphyloslide, and Hemastaph tests correctly identified 210 (87.9%), 221 (92.5%), 238 (99.6%), 239 (100%), and 236 (98.7%) of the S. aureus isolates, respectively. Of the S. aureus isolates that were TC positive at room temperature 68% required 24 h of incubation before coagulase production was detected. There was one false-negative SeroSTAT Staph result and one false-negative Hemastaph result. The Staphyloslide test yielded two noninterpretable results (both organisms were later confirmed as non-S. aureus), whereas there were six noninterpretable results recorded with the Hemastaph test (four organisms were classified as non-S. aureus, and two were classified as S. aureus). The SeroSTAT Staph, Staphyloslide, and Hemastaph tests were all more sensitive than the conventional SC and TC (37 degrees C) tests and were considerably more rapid than the TC test at either temperature.  相似文献   

19.
Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.  相似文献   

20.
The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacillin MICs of 2 to 8 microgram/ml). The Velogene is a 90-min assay using a chimeric probe to detect the mecA gene. MRSA-Screen is a 15-min latex agglutination test with penicillin-binding protein 2a antibody-sensitized latex particles. We compared these assays with the BBL Crystal MRSA ID System (Becton Dickinson, Cockeysville, Md.) and with PCR for mecA gene detection. A total of 397 clinical isolates of S. aureus were tested, consisting of 164 methicillin-susceptible strains, 197 MRSA strains, and 37 BORSA strains. All assays performed well for the identification of MRSA with sensitivities and specificities for Velogene, MRSA-Screen, and BBL Crystal MRSA ID of 98.5 and 100%, 98.5 and 100%, and 98.5 and 98%, respectively. Three MRSA strains were not correctly identified by each of the Velogene and MRSA-Screen assays, but repeat testing with a larger inoculum resolved the discrepancies. The BBL Crystal MRSA ID test misclassified four BORSA strains as MRSA. Both the Velogene and the MRSA-Screen assays are easy to perform, can accurately differentiate BORSA isolates from MRSA isolates, and provide a rapid alternative for the detection of methicillin resistance in S. aureus in clinical laboratories, especially when mecA PCR gene detection is unavailable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号