首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: To investigate the appropriateness of the treatment policy of stereotactic irradiation using both hypofractionated stereotactic radiotherapy (HSRT) and stereotactic radiosurgery (SRS) for arteriovenous malformations (AVMs) located in an eloquent region or for large AVMs and using SRS alone for the other AVMs. METHODS AND MATERIALS: Included in this study were 75 AVMs in 72 patients, with a mean follow-up of 52 months. Of the 75 AVMs, 33 were located in eloquent regions or were >2.5 cm in maximal diameter and were given 25-35 Gy (mean, 32.4 Gy) in four daily fractions at a single isocenter if the patient agreed to prolonged wearing of the stereotactic frame for 5 days. The other 42 AVMs were treated with SRS at a dose of 15-25 Gy (mean, 24.1 Gy) at the isocenter. The 75 AVMs were classified according to the Spetzler-Martin grading system; 21, 23, 28, 2, and 1 AVM were Grade I, II, III, IV, V, and VI, respectively. RESULTS: The overall actuarial rate of obliteration was 43% (95% confidence interval [CI], 30-56%) at 3 years, 72% (95% CI, 58-86%) at 5 years, and 78% (95% CI, 63-93%) at 6 years. The actuarial obliteration rate at 5 years was 79% for the 42 AVMs <2.0 cm and 66% for the 33 AVMs >2 cm. The 5- and 6-year actuarial obliteration rate was 61% (95% CI, 39-83%) and 71% (95% CI, 47-95%), respectively, after HSRT and 81% (95% CI, 66-96%) and 81% (95% CI, 66-96%), respectively, after SRS; the difference was not statistically significant. Radiation-induced necrosis was observed in 4 subjects in the SRS group and 1 subject in the HSRT group. Cyst formation occurred in 3 patients in the SRS group and no patient in the HSRT group. A permanent symptomatic complication was observed in 3 cases (4.2%), and 1 of the 3 was fatal. All 3 patients were in the SRS group. The annual intracranial hemorrhage rate was 5.5-5.6% for all patients. CONCLUSION: Our treatment policy using SRS and HSRT was as effective as the policy involving SRS alone. The HSRT schedule was suggested to have a lower frequency of radiation necrosis and cyst formation than the high-dose SRS schedule. The benefit of HSRT compared with lower dose SRS has not yet been determined.  相似文献   

2.
We have previously described the development of a technique which utilizes a standard linear accelerator to provide stereotactic, limited field radiation. The radiation is delivered using a modified and carefully calibrated 6 MV linear accelerator. Precise target localization and patient immobilization is achieved using a Brown-Roberts-Wells (BRW) stereotactic head frame which is in place during angiography, CT scanning, and treatment. Seventeen arteriovenous malformations (AVMs) have been treated in 16 patients from February 1986 to July 1988. Single doses of 1500-2500 cGy were delivered using multiple non-coplanar arcs with small, sharp edged x-ray beams to lesions less than 2.7 cm in greatest diameter. The dose distribution from this technique has a very rapid dropoff of dose beyond the target volume. Doses were prescribed at the periphery of the AVMs, typically to the 80-90% isodose line. Eleven of 16 patients have been followed by repeat angiography at least 1 year following treatment. Five of 11 have had complete obliteration of their AVM in 1 year and an additional three patients have achieved complete obliteration by 24 months. There have been no incidences of rebleeding or serious complications in any patient. We conclude that stereotactic radiosurgery using a standard linear accelerator is an effective and safe technique in the treatment of intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic treatments.  相似文献   

3.
4.
The effectivity of stereotactic percutaneous single dose irradiations in the treatment of solitary brain metastases has been assessed in a series of 12 consecutive patients. Only radioresistant deeply localized metastases have been treated. Photon-irradiation was carried out with the convergent beam technique using stereotactic localization methods, in a linear accelerator facility. In 11 of the 12 patients no side effects occurred. The first 7 patients, who could be observed 3 months or longer, have been studied in detail. In each of these cases single dose irradiation with 20-30 Gy yielded arrest of tumor growth. In one case a marked decrease in contrast enhancement and in four cases shrinkage of the metastasis as well as a marked decrease of the edema occurred. In every patient a marked, sometimes dramatic improvement of the clinical condition was achieved, beginning a few days after irradiation. Stereotactic radiosurgery is a valuable tool in the treatment of inoperable, radioresistant brain metastases, the major advantage being high efficacy and smoothness of the procedure, as well as extremely short hospitalization times (2-3 days).  相似文献   

5.
PURPOSE: This study was performed to evaluate the clinical outcomes of three-dimensional (3D) conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. MATERIALS AND METHODS: Forty patients who were treated between July 1998 and November 2000 and were followed for >10 months were included in this study. Of the 40 patients, 31 had primary lung cancer and 9 had metastatic lung cancer. The primary lung cancer was staged as T1N0M0, T2N0M0, and T3N0M0 in 19, 8, and 4 patients, respectively. The primary sites of metastatic lung cancer were the colon in 4, tongue in 2, and osteosarcoma, lung cancer, and hepatocellular carcinoma in 1 each. 3D treatment planning was performed to maintain the target dose homogeneity within 15% and to decrease the irradiated lung volume from >20 Gy to <25%. All patients were irradiated using a stereotactic body frame and received 4 times 10-12 Gy single high-dose radiation at the isocenter during a period of 5-13 days (median 12). RESULTS: The initial 3 patients received 40, and the remaining 37 patients received 48 Gy after dose escalation. Of the 33 tumors followed >6 months, 6 tumors (18%) disappeared completely after treatment. Twenty-five tumors (76%) decreased in size by 30% or more after treatment. Therefore, 31 tumors (94%) showed a local response. During the follow-up of 4-37 months (median 19), no pulmonary complications greater than National Cancer Institute-Common Toxicity Criteria Grade 2 were noted. Of the 16 patients with histologically confirmed T1N0M0 primary lung cancer who received 48 Gy, all tumors were locally controlled during the follow-up of 6-36 months (median = 19). In 9 tumors with lung metastases that were irradiated with 48 Gy in total, 2 tumors did not show a local response. Finally, 3 tumors (33%) with lung metastases relapsed locally at 6-12 months (median 7) after treatment during the follow-up of 3-29 months (median 18). CONCLUSION: 3D conformal hypofractionated single high-dose radiotherapy of 48 Gy in 4 fractions using a stereotactic body frame was useful for the treatment of lung tumors.  相似文献   

6.
Background The role of stereotactic irradiation using a linear accelerator for brain metastasis from renal cell carcinoma was investigated. Methods Fifteen brain metastases in 11 patients with a history of renal cell carcinoma were treated using convergent narrow x-ray beams from a linear accelerator and rigid fixation of the head with a stereotactic frame. Twelve metastatic tumors in8 patients were irradiated with 25 Gy at the center in a single fraction, and single tumors in 3 patients received the following doses: 25 Gy in 5 fractions, 28 Gy in 3 fractions, or 35 Gy in 4 fractions Results The actuarial local control rate at 12 months was 90.6%. Twelve (92%) of 13 lesions that produced neurologic symptoms before stereotactic irradiation showed an improvement of symptoms. No complication related to the irradiation was observed. The median survival time was 6 months. Conclusion Stereotactic irradiation is more effective in achieving local control than is conventional radiotherapy, and achieves improvement in symptoms and survival rates similar to those of surgical resection of the brain metastasis from renal cell carcinoma. Urologists and oncologists should be aware of the usefulness of stereotactic radiation in the management of patients with renal cell carcinoma.  相似文献   

7.
8.
Journal of Neuro-Oncology - The optimal treatment strategy for vestibular schwannoma (VS) is not known, and different radiation techniques and fractionation regimens are currently being used. This...  相似文献   

9.
Journal of Neuro-Oncology - While hypofractionated stereotactic radiotherapy (HFSRT) is being increasingly used for treating brain metastases, clinical data concerning the incidence and risk...  相似文献   

10.
We have recently initiated a program for irradiating small, unresectable arteriovenous malformations (AVM's) in the brain. The treatments are delivered using a modified and carefully calibrated 6 MV linac. We are using high, single doses (15 to 25 Gy) with a goal of sclerosing the vessels and preventing hemorrhages. This technique, radiosurgery, is somewhat controversial in the radiotherapy community. Since the treatment is given in a single sitting, rather than in the more conventional pattern of multiple small daily fractions, there is some concern about late radiation damage to the normal brain tissue. However an extensive review of the literature leads us to the conclusion that if a technique is used that keeps the volume irradiated to high dose small, radiosurgery is a safe and efficacious treatment for small (less than 2.5 cm) AVM's. To decrease the risk of necrosis of normal brain tissue, it is important to confine the high dose region as tightly as possible to the target volume. Precise target localization and patient immobilization is achieved using a stereotactic head frame which is used during angiography, CT scanning, and during the radiation treatment. This minimizes the margin of safety that must be added to the target volume for errors in localization and set-up. The treatment is delivered using multiple noncoplanar arcs, with small, sharp edged X ray beams, and with the center of the AVM at isocenter. This produces a rapid dropoff of dose beyond the target volume. Early results in our first few patients are encouraging.  相似文献   

11.
《Radiotherapy and oncology》2014,110(3):371-373
In order to target arteriovenous malformations (AVM) in a frameless approach, registration of two-dimensional (2D) digital-subtracted-angiographs (DSA) with three-dimensional (3D) computed tomography (CT) is required. Targeting accuracy and delineation of a frameless 2D-DSA and 3D-CT image registration tool based on bony anatomy of the skull was evaluated. This frameless approach assures accurate target localization and can be used in a clinical setting.  相似文献   

12.
Purpose/Objective: With the increasing number of patients successfully treated with stereotactic radiosurgery for brain metastases, decision making after therapy based on follow-up imaging findings becomes more and more important. Magnetic resonance imaging (MRI) is the most sensitive means for follow-up studies. The objective of this study was to investigate the treatment outcome of our radiosurgery program and to describe the response of brain metastases to contrast-enhanced MRI after linear accelerator (linac) stereotactic radiosurgery and identify factors to distinguish among local control and local failure.

Methods and Materials: Using serial MRI, we followed the course of 87 brain metastases in 48 consecutive patients treated between September 1996 and November 1997 with linac-based radiosurgery with 15-MV photons. Treatment planning was performed on an MR data cube. For spherical metastases, radiosurgery was delivered using a 9 noncoplanar arc technique with circular-shaped collimators. For irregularly shaped targets, radiosurgery was delivered using a manually driven multi-leaf collimator with a leaf width of 1.5 mm projected to the isocenter. Median radiosurgery dose was 20 Gy prescribed to the 80% isodose. Together with whole brain radiotherapy (20 × 2 Gy, 5/w), a median radiosurgical dose of 15 Gy was delivered. Median follow-up was 8 (range 2–36) months. Factors influencing local control and survival rates were analyzed with respect to MRI response, and Kaplan-Meier curves were calculated.

Results: Actuarial local tumor control was 91% at one and two years. Patient survival at one and two years was 30% and 18%. Median survival was 9 months. During follow-up in 70 (81%) of the 87 treated metastases, the contrast-enhancing volumes on T1W images were stable or disappeared partly or completely. A transient enlargement of contrast-enhancing volumes was observed in 11 (12%) of the 87 lesions treated, while a progressive enlargement due to local treatment failure was observed in 6 (7%) of the 87 treated metastases. Younger age, early contrast onset after radiosurgery, and previous chemotherapy were associated with this transient enlargement of contrast-enhancing lesion volume.

Conclusions: Linac-based radiosurgery is an effective, noninvasive, and safe treatment option for patients with brain metastases. A marked enlargement of the contrast-enhancing volume on T1-weighted MR images after radiosurgery is a sensitive predictor for, but not equivalent with, local failure. In as many as two-thirds of the cases with contrast enlargement in MRI follow-up, the contrast enlargement is transient with no need for further treatment. While some MRI findings are more likely if transient enlargement is present, a clear decision cannot be made based on MRI, and ultimately the clinical status dictates further action.  相似文献   


13.
The use of a 4 MV linear accelerator1 for whole body irradiation is described in this study. The room size limits the focus to skin distance to 279 cm. At this distance a maximum field length of 162 cm is achieved by: (a) using the diagonal of the beam by rotating the collimator 45°; (b) adding a special flattening filter which increases the useful field length. The horizontal beam is directed either laterally (patient supine) or anteroposteriorly (patient on side). The dose heterogeneity for both these geometries was measured in a phantom7 loaded with Li2B4O7 thermoluminescent dosimeters (TLD) and film.71 The lateral treatment geometry causes significantly larger dose heterogeneity than the anteroposterior treatment. Because of the increased dose to the lungs in either one of these treatment geometries, the use of compensators in this region is suggested.  相似文献   

14.
15.
Corticospinal tract (CST) information using anisotropic diffusion-weighted imaging and magnetoencephalography were integrated into radiosurgical planning for two patients with deeply seated arteriovenous malformation. The volume of CST receiving >10 Gy, >15 Gy, and maximum dose of CST could be reduced when plans were created with the aid of CST information compared with plans without the information. The results indicate that the use of CST information might reduce the risk of post-radiosurgical motor disturbance resulting from radiation necrosis.  相似文献   

16.
We have developed a novel irradiation technique for lung cancer that combines a linear accelerator and CT scanner with patient-controlled breath-hold and radiation beam switching. We applied this technique to stereotactic three-dimensional (3D) conformal radiotherapy for stage I non-small cell lung cancer (NSCLC) and evaluated the primary therapeutic outcomes. A total of 35 patients with stage I (15 IA, 20 IB) primary NSCLC (20 adeno, 13 squamous cell, and 2 others) were treated with this technique. Patients ranged from 65 to 92 years old (median, 78 years). Twenty-three (66%) patients were medically inoperable due to mainly chronic pulmonary disease or high age. Three-dimensional treatment plans were made using 10 different non-coplanar dynamic arcs. The total dose of 60 Gy was delivered in 10 fractions (over 5-8 days) at the minimum dose point in the planning target volume (PTV) using a 6 MV X-ray. After adjusting the isocenter of the PTV to the planned position by a unit comprising CT and linear accelerator, irradiation was performed under patient-controlled breath-hold and radiation beam switching. All patients completed the treatment course without complaint. Complete response (CR) and partial response (PR) rates were 8/35 (23%) and 25/35 (71%), respectively. Pulmonary complications of National Cancer Institute-Common Toxicity Criteria grade >2 were noted in three (9%) patients. During follow-up (range, 6-30 months; median, 13 months), two (6%) patients developed local progression and five (14%) developed distant or regional lymph node metastases. Two-year overall survival rates for total patients and medically operable patients were 58 and 83%, respectively. In conclusion, this new irradiation technique, utilizing patient-controlled radiation beam switching under self-breath-hold after precise alignment of the isocenter, allows safe high-dose stereotactic radiotherapy with sufficient margins around the CTV and reduced treatment times. Based on the initial results, excellent local control with minimal complications is expected for stage I NSCLC.  相似文献   

17.
PURPOSE: To evaluate intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy (SRT) for lung or liver cancers, we checked repeated CT scanning, with a fusion of CT and linear accelerator (FOCAL) unit. METHODS AND MATERIALS: The FOCAL unit is a combination of a linear accelerator (Linac), CT scanner, X-ray simulator (X-S), and carbon table, and is designed to achieve CT-guided SRT with daily CT positioning followed by immediate irradiation while patients keep reduced shallow respirations. To evaluate intrafractional tumor position stability, 50 lung or liver lesions in 20 patients were checked by repeated CT scanning just before and after irradiation, and the obtained images were compared. RESULTS: There was no case with the intrafractional error judged to be greater than 10 mm. In 68% of cases, the intrafractional positioning errors were negligible (0-5 mm). CONCLUSIONS: Using the FOCAL unit, SRT for lung or liver cancers could be performed with intrafractional positioning errors not greater than 10 mm.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号