首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach.  相似文献   

2.
In a previous study, the predictive capacity of a modified local lymph node assay (LLNA) based on cell counts, the LNCC, was demonstrated to be closely similar to that of the original assay. In addition, a range of substances, including some technical/commercial materials and a range of agrochemical formulations (n = 180) have also been assessed in both methods in parallel. The results in the LNCC and LLNA were generally consistent, with 86% yielding an identical classification outcome. Discordant results were associated with borderline data and were evenly distributed between the two methods. Potency information derived from each method also demonstrated good consistency (n = 101), with 93% of predictions being close. Skin irritation was observed only infrequently and was most commonly associated with positive results; it was not associated with the discordant results. Where different vehicles were used with the same test material, the effect on sensitizing activity was modest, consistent with historical data. Analysis of positive control data indicated that the LNCC and LLNA displayed similar levels of biological variation. When taken in combination with the previously published results on LLNA Performance Standard chemicals, it is concluded that the LNCC provides a viable non‐radioactive alternative to the LLNA for the assessment of substances, including potency predictions, as well as for the evaluation of preparations. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Recently UN GHS has introduced the sub-categorization of skin sensitizers for which ECt (concentration estimated to induce stimulation index above threshold) of the murine local lymph node assay (LLNA) is used as criteria. Non-radioisotopic variants of LLNA, LLNA: DA, LLNA: BrdU-ELISA, LNCC and LLNA: BrdU-FCM were developed yet their utilities for potency sub-categorization are not established. Here we assessed the agreement of LLNA variants with LLNA or human data in potency sub-categorization for 22 reference substances of OECD TG429. Concordance of sub-categorization with LLNA was highest for LLNA: BrdU-FCM(91%, κ = 0.833, weighted kappa) followed by LLNA: BrdU-ELISA (82%, κ = 0.744) and LLNA: DA (73%, κ = 0.656) whereas LNCC only showed a modest association (64%, κ = 0.441). With human data, LLNA agreed best (77%) followed by LLNA: DA and LLNA: BrdU-FCM(73%), LLNA: BrdU-ELISA (68%) and LNCC(55%). Bland-Altman plot revealed that ECt's of LLNA variants largely agreed with LLNA where most values fell within 95% limit of agreement. Correlation between ECt's of LLNA and LLNA variants were high except for LNCC(pair-wise with LLNA, LLNA: DA, r = 0.848, LLNA: BrdU-ELISA, r = 0.744, LLNA: BrdU-FCM, r=0.786, and LNCC, r = 0.561 by Pearson). Collectively, these results demonstrated that LLNA variants exhibit performance comparable to LLNA in the potency sub-categorization although additional substances shall be analyzed in the future.  相似文献   

4.
To evaluate the reliability of the murine local lymph node assay (LLNA), a test for allergic contact dermatitis activity, the inter- and intralaboratory consistency statistics (h and k, respectively) were calculated for validation studies testing multiple chemicals. The analysis indicated the absence of excessive variability in the dose calculated to induce a threefold or greater increase in the stimulation index (SI). To assess the appropriateness of using an SI of 3 as the decision criteria for identifying a sensitizing compound, LLNA results based on SI values of 2.0, 2.5, 3.0, 3.5, and 4.0 were compared with guinea pig or human results. The results supported the use of an SI of 3 as the decision criteria. Assay performance was determined by comparing LLNA results to results obtained for guinea pigs or humans. The accuracy of the LLNA was 89% when compared with results from the guinea pig maximization test (GPMT)/Buehler assay (BA). The performance of the LLNA and the GPMT/BA was similar when each was compared to human maximization test results plus substances included as human patch test allergens. The LLNA offered advantages over the GPMT in respect to both the time required to conduct the test and the assay cost.  相似文献   

5.
To evaluate the reliability of the murine local lymph node assay (LLNA), a test for allergic contact dermatitis activity, the inter- and intralaboratory consistency statistics (h and k, respectively) were calculated for validation studies testing multiple chemicals. The analysis indicated the absence of excessive variability in the dose calculated to induce a threefold or greater increase in the stimulation index (SI). To assess the appropriateness of using an SI of 3 as the decision criteria for identifying a sensitizing compound, LLNA results based on SI values of 2.0, 2.5, 3.0, 3.5, and 4.0 were compared with guinea pig or human results. The results supported the use of an SI of 3 as the decision criteria. Assay performance was determined by comparing LLNA results to results obtained for guinea pigs or humans. The accuracy of the LLNA was 89% when compared with results from the guinea pig maximization test (GPMT)/Buehler assay (BA). The performance of the LLNA and the GPMT/BA was similar when each was compared to human maximization test results plus substances included as human patch test allergens. The LLNA offered advantages over the GPMT in respect to both the time required to conduct the test and the assay cost.  相似文献   

6.
The validation of alternative methods is a relatively new activity in toxicology. The local lymph node assay (LLNA), a novel method for the identification of chemicals that have the potential to cause skin sensitization, was the first test to pass through the formal regulatory validation process established in the USA under the auspices of ICCVAM, the Interagency Coordinating Committee on the Validation of Alternative Methods. ICCVAM approved the LLNA as an alternative to guinea pig tests for the identification of skin sensitisation hazards. In this report, we explore the nine recommendations made by ICCVAM and discuss their interpretation in relation to the new OECD Guideline 429, which describes the LLNA. In particular, the value and limitations of the use of statistical evaluation of data and of the inclusion of routine positive controls is examined. It is concluded that the OECD Guideline as currently written embodies the necessary flexibility to permit conduct of the LLNA in a manner necessary to meet the varying needs of regulatory agencies and toxicologists around the world.  相似文献   

7.
Allergic contact dermatitis is a serious health problem. Over the last decade, the murine local lymph node assay (LLNA) has been developed to detect chemical allergens, and international validation studies have been conducted. We have tried to establish an alternative non-radioisotopic endpoint for the LLNA by using 5-bromo-2'-deoxyuridine (BrdU) incorporation in place of radioisotopes, such as [3H]thymidine, employed in the standard method. BrdU was given as a single administration at 5 mg/animal 2 days following three consecutive daily applications of a test chemical. BrdU incorporation into draining lymph node cells was measured using an enzyme immunosorbent assay technique. In this study, p-benzoquinone(PBQ), trimellitic anhydride (TMA), citral(CT) and dextran (DEX) were used as pilot chemicals. PBQ, TMA and CT, which are classified as moderate to strong sensitizers in the guinea pig maximization test and were positive in the original LLNA, were also found to elicit positive responses in the alternative LLNA using BrdU incorporation. In contrast, DEX tested negative in the modified assay consistent with previous guinea pig and LLNA data. Consequently, the modified LLNA endpoint using BrdU incorporation may represent a useful alternative to the standard assay in situations, where there is a need to avoid the use of radioisotopes.  相似文献   

8.
The replacement of animal use in testing for regulatory classification of skin sensitizers is a priority for US federal agencies that use data from such testing. Machine learning models that classify substances as sensitizers or non‐sensitizers without using animal data have been developed and evaluated. Because some regulatory agencies require that sensitizers be further classified into potency categories, we developed statistical models to predict skin sensitization potency for murine local lymph node assay (LLNA) and human outcomes. Input variables for our models included six physicochemical properties and data from three non‐animal test methods: direct peptide reactivity assay; human cell line activation test; and KeratinoSens™ assay. Models were built to predict three potency categories using four machine learning approaches and were validated using external test sets and leave‐one‐out cross‐validation. A one‐tiered strategy modeled all three categories of response together while a two‐tiered strategy modeled sensitizer/non‐sensitizer responses and then classified the sensitizers as strong or weak sensitizers. The two‐tiered model using the support vector machine with all assay and physicochemical data inputs provided the best performance, yielding accuracy of 88% for prediction of LLNA outcomes (120 substances) and 81% for prediction of human test outcomes (87 substances). The best one‐tiered model predicted LLNA outcomes with 78% accuracy and human outcomes with 75% accuracy. By comparison, the LLNA predicts human potency categories with 69% accuracy (60 of 87 substances correctly categorized). These results suggest that computational models using non‐animal methods may provide valuable information for assessing skin sensitization potency. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

9.
New test methods are being developed to improve the prediction of human and environmental risks and to benefit animal welfare by reducing, refining, and replacing animal use. Regulatory adoption of new test methods is often a complex and protracted process, requiring test method validation, regulatory acceptance, and implementation. Assessments of new test methods have not always been uniform within or among regulatory agencies. Thus, there have been increased pressures for a harmonized approach to test method evaluation and acceptance. In 1997, in response to these pressures and to U.S. Public Law 103-43, the National Institute of Environmental Health Sciences (NIEHS) established the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) to coordinate interagency consideration of new and revised test methods. This article describes the validation and acceptance criteria and process used for the first test method evaluated by ICCVAM, the murine local lymph node assay (LLNA). Based on ICCVAM's conclusions and recommendations, the LLNA has been accepted by U.S. regulatory agencies as a stand-alone assay for allergic contact dermatitis. Two related articles in this series of three present the results of the independent peer review evaluation of the LLNA and summarize the performance characteristics of the database substantiating the validity of the LLNA.  相似文献   

10.
New test methods are being developed to improve the prediction of human and environmental risks and to benefit animal welfare by reducing, refining, and replacing animal use. Regulatory adoption of new test methods is often a complex and protracted process, requiring test method validation, regulatory acceptance, and implementation. Assessments of new test methods have not always been uniform within or among regulatory agencies. Thus, there have been increased pressures for a harmonized approach to test method evaluation and acceptance. In 1997, in response to these pressures and to U.S. Public Law 103-43, the National Institute of Environmental Health Sciences (NIEHS) established the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) to coordinate interagency consideration of new and revised test methods. This article describes the validation and acceptance criteria and process used for the first test method evaluated by ICCVAM, the murine local lymph node assay (LLNA). Based on ICCVAM's conclusions and recommendations, the LLNA has been accepted by U.S. regulatory agencies as a stand-alone assay for allergic contact dermatitis. Two related articles in this series of three present the results of the independent peer review evaluation of the LLNA and summarize the performance characteristics of the database substantiating the validity of the LLNA.  相似文献   

11.
12.
The new OECD guideline 429 (skin sensitization: local lymph node assay) is based upon a protocol, which utilises the incorporation of radioactivity into DNA as a measure for cell proliferation in vivo. The guideline also enables the use of alternative endpoints in order to assess draining lymph node (LN) cell proliferation. Here we describe the first round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in seven laboratories. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products, Swissmedic. Statistical analyses of all data were performed by an independent centre at the University of Bern, Department of Statistics. Ear-draining, LN weight and cell count were used to assess proliferation instead of radioactive labeling of lymph node cells. In addition, the acute inflammatory skin reaction was measured by ear swelling and weight of circular biopsies of the ears to identify skin irritating properties of the test items. Hexylcinnamaldehyde (HCA) and three blinded test items were applied to female, 8--10 weeks old NMRI and BALB/c mice. Results were sent via the independent study coordinator to the statistician. The results of this first round showed that the alternative endpoints of the LLNA are sensitive and robust parameters. The use of ear weights added an important parameter assessing the skin irritation potential, which supports the differentiation of pure irritative from contact allergenic potential. There were absolute no discrepancies between the categorisation of the three test substances A--C determined by each single participating laboratories. The results highlighted also that many parameters do have an impact on the strength of the responses. Therefore, such parameters have to be taken into consideration for the categorisation of compounds due to their relative sensitizing potencies.  相似文献   

13.
The local lymph node assay (LLNA) is the assay of choice in European regulatory toxicology. As with other toxicology/sensitisation assays, it has a potential for false results, the anionic surfactant sodium lauryl sulphate (SLS) representing a classic example. In the work reported here, examples of false positives in the LLNA are compared to published “benchmarks” such as SLS. Clear false positives (e.g. oleic acid) are also contrasted with examples where data interpretation is more challenging. As the LLNA will be applicable to >30,000 chemicals under REACH, and in the light of animal welfare considerations to do no more than the absolute minimum of animal testing, results from a single LLNA often represent the only available data on sensitisation. This reinforces the need to ensure data from this assay are interpreted intelligently, using scientific analysis of results and considering the weight of evidence, before decisions are made on which substances should be classified as representing a skin sensitisation hazard. In chemical classes where the LLNA has been shown to be an inappropriate assay other standardised methods (e.g. the Buehler or Magnusson and Kligman guinea pig tests [OECD 406]) should be employed as the first choice assays.  相似文献   

14.
The validation status of the murine local lymph node assay (LLNA), a method for assessing the allergic contact dermatitis potential of chemicals, was evaluated by an independent peer review panel (Panel) convened by the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM). The LLNA measures lymphocyte proliferation using incorporation of radioactive thymidine or iododeoxyuridine into cells of the draining lymph nodes of mice topically exposed to a test article. The Panel concluded that the assay performed as well as currently accepted guinea pig methods [guinea pig maximization test (GPMT)/Buehler assay (BA)] for the hazard identification of strong to moderate chemical sensitizing agents, but that it might not correctly identify all weak sensitizers or metals (potential false negative response) or all strong irritants (potential false positive response). The Panel concluded also that the LLNA involves less pain and distress than conventional guinea pig methods. The Panel unanimously recommended the LLNA as a stand-alone alternative for contact sensitization hazard assessment, provided that certain protocol modifications were made. These included collection of individual, rather than pooled, animal response data; the inclusion of a concurrent positive control; and consideration of dose-response information and statistical analyses. A standardized LLNA protocol is provided.  相似文献   

15.
The local lymph node assay (LLNA) is used to assess the skin sensitization potential of chemicals. In the standard assay, mice are treated topically on the dorsum of both ears with test substance for 3 days. Following 2 days of rest, the initiation of the hypersensitivity response is evaluated by injecting (3)H-thymidine into a tail vein, and then measuring the levels of radioisotope incorporated into the DNA of lymph node cells draining the ears. In the current study, BALB/c mice were treated with the contact sensitizers hexylcinnamic aldehyde (HCA) and oxazolone, and the nonsensitizer methyl salicylate. The proliferative response of lymph node cells was evaluated in an ex vivo assay, in which isolated cells were cultured in vitro with (3)H-thymidine. Treatment of mice with HCA at 5-50% resulted in concentration-related increases in (3)H-thymidine incorporation, with stimulation indices ranging from 3 to 14. Low animal-to-animal variability was seen in three replicate assays testing HCA at 25%. As anticipated, the proliferative response induced by the potent sensitizer oxazolone at 0.25% was greater than HCA at all concentrations tested. Stimulation indices of 1.5 and 3 were seen in two independent experiments with methyl salicylate. These equivocal findings were likely due to the irritancy properties of the compound. Importantly, measuring ex vivo (3)H-thymidine incorporation was more sensitive than evaluating lymph node weight and cellularity, and in vitro bromodeoxyuridine incorporation. Furthermore, the results of the ex vivo LLNA were comparable to the standard assay. This study provided evidence that supports the use of an ex vivo LLNA for hazard assessment of contact hypersensitivity.  相似文献   

16.
The local lymph node assay (LLNA) is a regulatory accepted test for the identification of skin sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. However, there is evidence that LLNA is overestimating the sensitization potential of certain substance classes in particular those exerting skin irritation. Some reports describe the additional use of flow cytometry‐based immunophenotyping to better discriminate irritants from sensitizing irritants in LLNA. In the present study, the 22 performance standards plus 8 surfactants were assessed using the radioactive LLNA method. In addition, lymph node cells were immunophenotyped to evaluate the specificity of the lymph node response using cell surface markers such as B220 or CD19, CD3, CD4, CD8, I‐Aκ and CD69 with the aim to allow a better discrimination above all between irritants and sensitizers, but also non‐irritating sensitizers and non‐sensitizers. However, the markers assessed in this study do not sufficiently differentiate between irritants and irritant sensitizers and therefore did not improve the predictive capacity of the LLNA. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
The validation status of the murine local lymph node assay (LLNA), a method for assessing the allergic contact dermatitis potential of chemicals, was evaluated by an independent peer review panel (Panel) convened by the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM). The LLNA measures lymphocyte proliferation using incorporation of radioactive thymidine or iododeoxyuridine into cells of the draining lymph nodes of mice topically exposed to a test article. The Panel concluded that the assay performed as well as currently accepted guinea pig methods [guinea pig maximization test (GPMT)/Buehler assay (BA)] for the hazard identification of strong to moderate chemical sensitizing agents, but that it might not correctly identify all weak sensitizers or metals (potential false negative response) or all strong irritants (potential false positive response). The Panel concluded also that the LLNA involves less pain and distress than conventional guinea pig methods. The Panel unanimously recommended the LLNA as a stand-alone alternative for contact sensitization hazard assessment, provided that certain protocol modifications were made. These included collection of individual, rather than pooled, animal response data; the inclusion of a concurrent positive control; and consideration of dose–response information and statistical analyses. A standardized LLNA protocol is provided.  相似文献   

18.
The advent of the local lymph node assay (LLNA), and efforts to develop in vitro alternatives for the identification of skin sensitizing chemicals has focused attention on the issue of false positive and false negative results. In essence, the question becomes ‘what is the gold standard?’ In this context, attention has focused primarily on the LLNA as this is now the preferred assay for skin sensitization testing. However, for many years prior to introduction of the LLNA, the guinea pig maximization test and the occluded patch test of Buehler were the methods of choice. In order to encourage a more informed dialogue about the relative performance, accuracy and applicability of the LLNA and guinea pig tests, we have here considered the extent to which guinea pig methods were themselves subject to false positives and negative results. We describe and discuss here well‐characterized examples of instances where both false negatives (including abietic acid and eugenol) or false positives (including vanillin and sulfanilic acid) have been recorded in guinea pig tests. These and other examples are discussed with particular reference to the fabrication of a gold standard dataset that is required for the validation of in vitro alternatives. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
The amino acid derivative reactivity assay (ADRA) is an alternative method for evaluating key event 1 (KE-1) in the skin sensitization mechanism included in OECD TG442C (OECD, 2021). Recently, we found that ADRA with a 4-mM test chemical solution had a higher accuracy than the original ADRA (1 mM). However, ADRA (4 mM) has yet to be evaluated using integrated approaches to testing and assessment (IATA), a combination of alternative methods for evaluating KE. In this study, the sensitization potency of three defined approaches (DAs) using ADRA (4 mM) as KE-1 was predicted and compared with those of two additional ADRAs or direct peptide reactivity assay (DPRA): (i) “2 out of 3” approach, (ii) “3 out of 3” approach, and (iii) integrated testing strategy (ITS). In the hazard identification of chemical sensitizers, the accuracy of human data and local lymph node assay (LLNA) remained almost unchanged among the three approaches evaluated. Potency classifications for sensitization were predicted with the LLNA and human data sets using ITS. The potency classifications for the sensitization potency prediction accuracy of LLNA data using any alternative method were almost unchanged, at approximately 70%, and those with ITS were not significantly different. When ITS was performed using DPRA, the prediction accuracy was approximately 73% for human data, which was similar to that of the LLNA data; however, the accuracy tended to increase for all ADRA methods. In particular, when ITS was performed using ADRA (4 mM), the prediction accuracy was approximately 78%, which proved to be a practical level.  相似文献   

20.
Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号