1.
Antitachycardia pacing in ventricular tachyarrhythmias (VT) is associated with potential acceleration of VT: frequency of VT and discomfort of the patient (pt) can limit treatment with the AICD. We therefore evaluated the combined use of antitachycardia pacing and AICD in 6 of 14 patients (age 50–70. mean 60 years) with AICD implantation because of VT, which could he terminated by temporary overdrive pacing. With the interactive mode of the Tachylog, termination of VT by the pacemaker as well as by the AICD was assessed after implantation. In the automatic mode, the Tachylog functioned as a bipolar VVI device with antitachycardia burst stimulation: 2–5 stimuli, interval 260–300 ms. 1–2 interventions. During follow-up of 12±5 months, the Tachylog terminated VT reliably 20 to 327 times per patient. In three patients, burst stimulation accelerated VT, which was terminated then by the AICD discharge. Conclusion: Drug resistant ventricular tachyarrhythmias can be terminated by the Tachylog pacemaker avoiding patients' discomfort. In case of acceleration. ventricular tachyarrhythmias can be controlled by the automatic implantable cardioverter/defibrillator. A universal pacemaker should combine antitachycardia pacing with back-up defibrillation mode.  相似文献   

2.
Antitachycardia pacing for ventricular tachycardia (VT) is associated with the possibility of fibrillating the heart; on the other hand, the frequency of VT and patient discomfort can limit treatment with the automatic implantable cardioverter/defibrillator (AICD). To contribute to the further development of a universal pacemaker, we evaluated the combined use of the antitachycardia pacemaker ("tachylog") and the AICD in five patients with recurrent VT. In the automatic mode, the "tachylog" worked as a bipolar VVI pacemaker. For antitachycardia pacing, a burst of rapid ventricular pacing was delivered at about 80% of the cycle length. During a follow-up period of 5 +/- 2 months (range, 3 to 8) two to 291 successful interventions of antitachycardia pacing were counted from diagnostic data which had been collected by the pulse generator during the course of treatment. When the antitachycardia pacemaker failed to terminate VT, the AICD was activated. In the individual case, between 0 and 41 discharges of the AICD were delivered. The high pulse energy of the AICD did not damage the antitachycardia pacemaker; no interference of the two devices was observed. Future antitachycardia systems should be more flexible with regard to detection and termination modes, combining antitachycardia pacing with back-up defibrillation.  相似文献   

3.
Appropriately timed noncompetitive ventricular pacing potentially may initiate ventricular tachycardia in patients prone to these arrhythmias. The combination of bradycardia pacing and stored electrograms in a currently available cardioverter defibrillator provides an opportunity to evaluate the occurrence of such pacing induced ventricular tachycardia. During a surveillance period of 18.7 ± 11.4 months, stored electrograms documented 302 episodes of ventricular tachycardia in 77 patients. Five patients (6.5%) demonstrated 25 episodes (1–16 per patient) of ventricular tachycardia that were immediately preceded by an appropriately paced ventricular beat (8.3% of all episodes of ventricular tachycardia). All five patients had prior myocardial infarctions and a history of monomorphic ventricular tachycardia occurring both spontaneously and in response to programmed electrical stimulation. Antitachycardia pacing terminated pacing induced ventricular tachycardia in 22 episodes; in one episode antitachycardia pacing accelerated ventricular tachycardia. In two cases shock therapy was aborted for nonsustained ventricular tachycardia. We conclude that, in selected postinfarction patients with recurrent sustained monomorphic ventricular tachycardia treated with implantable cardioverter defibrillators, appropriately timed ventricular pacing may induce ventricular tachycardia.  相似文献   

4.
Antitachycardia pacemakers and implantable cardioverter defibrillators (ICD) were implanted in 14 patients to control recurrent hemodynamically stable ventricular tachycardia (VT), All patients underwent extensive preimplant testing in the elecrrophysiology laboratory documenting that in each patient at least 50 episodes of VT could be reliably terminated by an external model of the antitachycardia pacemaker. The burst scanning mode of anfitachycardia pacing was used in all patients. ICDs were implanted solely as a back up should acceleration of VT occur, and all had high nonprogrammable rate cutoffs (mean 191 ± 12 beats/min). During a mean follow-up of 25 ± 6 months, 6,029 episodes of VT were treated in the 14 patients. Only 103 ICD discharges were required (approximately one discharge per 60 episodes of VT). Ten of the 14 patients received discharges from their ICDs. No deaths have occurred. All devices remain active and in the automatic mode. Thus, an antitachycardia pacemaker and ICD combination can safely and effectively terminate VT in highly selected patients who are subjected to extensive preimplant testing. In such patients, the vast majority of episodes of VT can be terminated with antitachycardia pacing, and only rarely is a discharge required from the ICD.  相似文献   

5.
This article describes our experience with an antitachycardia pacemaker alone (N = 3) or in combination with an automatic implontoble cardioverter defibrillator (AICD, N = 8) in the treatment of ventricular tochycardia. EJeven patients (mean ejection fraction 31%, mean oge 67 years) received an antitachycardia pacemaker. Nine had their units programmed for automatic antitachycardia pacing, one unit was programmed to automatic antitachycardia pacing by magnet activation only, and one to tachycardia detection and bradycardia support. Of the nine patients with automatic antitachycardia pacing, seven received appropriate and successful pace termination of spontaneous ventricular tachycardia at up to 120 times per month. Eight of these nine have had AICD implantations as well. There were no operative complications. Over a mean (± SD) follow-up of 12.1 ± 9.3 months (range 3–29 months), there have been two deaths, both due to heart failure. There have been four AICD discharges in three patients. Two units discharged in a clinically appropriate setting. The other two units, both with rate cutoffs <200 beats/min, were inadvertently triggered by the antitachycardia pacemaker and/or the underlying rate. In addition to the careful selection of the defibrillator rate cutoff, adverse device-device interactions were avoided by careful intraoperative lead positioning, and the disabling of bradycardia pacing when not needed or contraindicated. Antitachycardia pacing, with the safety provided by the AICD, is an effective treatment for patients with medically refractory ventricular tachycardia.  相似文献   

6.
Ventricular tachycardias can be terminated by a variety of pacemaker techniques, including rapid and slow stimulation. Fast tachycardias are typically poorly tolerated, and require prompt intervention, usually with rapid pacing. Termination of ventricular tachycardia by slow or single capture pacemaker stimulation techniques is attractive, because of its presumed safety and the possibility of using simple implantable pacers. To identify factors favoring termination, single capture stimulation was used in 390 episodes of ventricular tachycardia in 21 patients, 16 with coronary artery disease, able to tolerate ventricular tachycardia forseveral minutes. Single capture stimulation terminated 223 episodes (57%) in 18 patients, and two were accelerated. Of 157 episodes exposed to 2–3 programmed extrastimuli or rapid pacing 149 (94%) were terminated and 7 were accelerated. Direct current cardioversion was needed in 12 episodes. Without medications, only two patients tolerated VT. Only one patient had reliable termination with single capture stimulation over several days. Systolic blood pressure was similar in episodes terminated and not terminated by single capture stimulation, but the ventricular rate was significantly lower in episodes terminated, 116 ± 19 vs. 133 ±24 (p<0.001). Termination of ventricular tachycardia was not affected by QRS morphology. Single capture termination of ventricular tachycardia is largely unpredictable, with limited reproducibility over a period of time. Although comparatively safe, single capture techniques are not likely toprove useful in the long-term treatment of many patients with recurrent ventricular tachycardia.  相似文献   

7.
A 74-year-old man with a dual-chamber implantable cardioverter defibrillator implanted 3 years before experienced multiple ventricular tachycardias (VTs). All episodes were initiated by pacemaker-mediated tachycardia (PMT) that was either stopped by atrial undersensing or the tachycardia termination algorithm of the device. After the termination of PMT, two rapid ventricular paced beats, the first initiated by artificial triggering and the second due to retrograde conduction of the first one, initiated VT that was successfully terminated by antitachycardia pacing or a direct current shock of the device . All episodes revealed this pattern of initiation with a short-long-short ventricular sequence inducing VT.  相似文献   

8.
We evaluated the combined use of permanent automatic antitachycardia pacemakers and implanted defibrillators in fen patients with recurrent monomorphic sustained ventricular tachycardia (VT). Pacemaker programming was VVI-T automatic burst in eight patients, VVI-T magnet mode in one patient, and VVI in one patient. Device interactions occurred in four patients, requiring changes in pacemaker programming. These included defibrillator multiple counting during pacing, in-appropriate pacemaker bursts initiating VT, inappropriate reset of the pacemaker antitachycardia mode by defibrillation, defibrillator discharge after pacemaker VT termination, and defibrillator VT reinitiation. Two patients required pacemaker programming out of the antitachycardia mode, and two required a change in antitachycardia pacing parameters. Seven patients remain in automatic VVI-T and three in VVI modes. Mean follow-up is 13 months and all patients are alive. Thus, although pacemaker/ defibrillafor combinations function well for patients with more than one VT rate, device interactions occur frequently and may require pacemaker reprogramming or elimination of the overdrive mode. Combined use of these devices should be cautiously considered when single device therapy is unsatisfactory. Devices that combine both pacing and defibrillation features may reduce adverse interaction.  相似文献   

9.
Holter Documented Sudden Death in a Patient with an Implanted Defibrillator   总被引:1,自引:0,他引:1  
A 68-year-old man with recurrent attacks of monomorphic ventricular tachycardia (VT) received a pacer cardioverter defibrillator featuring antitachycardia pacing and cardioversion/defibrillation. Over 300 episodes of VT were successfully terminated by antitachycardia pacing. During Holter monitoring the patient experienced supraventricular tachycardia with delivery of multiple antitachycardia pacing, cardioversion, and defibrillation therapies ending with the death of the patient. The following factors played a role in the unfortunate outcome of this patient: 1. triggering of VT therapy by an unexpected high sinus rate; 2. atrial fibrillation induced by cardioversion therapy; 3. a gradual and continuous increase in rate during atrial fibrillation possibly caused by repeated VT and ventricular fibrillation therapies and/or by a thrombus, found at autopsy, in a bypass graft; and 4. the limited ability of presently available defibrillators to distinguish between ventricular and supraventricular arrhythmias.  相似文献   

10.
The efficacy and safety of external programmable automatic antitachycardia pacemakers (ATPs) used in the critical care setting for recurrent sustained monomorphic ventricular tachycardia (VT) was evaluated. Ten patients who had failed a mean of 4.0 +/- 1.4 antiarrhythmic medications (range 2-7) and who had previously required electrical cardioversion for VT were enrolled. Prior to ATP use, successful overdrive pacing termination of VT was demonstrated in all patients. Intertach (Intermedics, Inc.; n = 9) and Orthocor II (Cordis, Inc.; n = 1) ATPs were attached to temporary bipolar transvenous or epicardial pacing leads. Mean patient age was 66.4 +/- 11.5 years, and mean left ventricular ejection fraction was 22 +/- 7.5%. At the time of initial ATP use, mean VT cycle length was 347 +/- 88 msec (range 280-550 msec). A burst scanning antitachycardia pacing algorithm was used in each patient; one patient was also treated with a fixed rate burst adapted to VT cycle length. The duration of ATP use ranged from 2-25 days (median 5), successfully terminating greater than 3,369 VT episodes (median 3, range 0 to greater than 3,103 episodes per-patient). Two episodes of ATP induced rate acceleration occurred, each successfully terminated by the ATP. Only two patients required external cardioversion during ATP use, one for primary ventricular fibrillation and one for rapid polymorphic VT associated with antiarrhythmic drug withdrawal. ATPs also provided antibradycardia pacing and allowed for serial programmed ventricular stimulation. No complications were associated with transvenous catheter or ATP use.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

11.
FROMER, M., ET AL.: Clinical Experience with the Intertach 262-12 Pulse Generator in Patients with Recurrent Supraventricular and Ventricular Tachycardia. An antitachycardia pulse generator, the Intermedics Intertach 262-12 was implanted in 16 patients (14 patients with supraventricular tachycardia of various origins and two patients with recurrent ventricular tachycardia), who were not responsive to various antiarrhythmic drug regimens. The follow-up was from 6–49 months (mean 30.9 ± 13.8). Five patients had a follow-up of over 3 years. The device was used in all patients. One patient with ventricular tachycardia died from a nonarrhythmic cause. Loss of responsiveness to burst pacing was observed in 1/14 patients with supraventricular tachycardia and nontolerance of antitachycardia pacing in one patient. Overall clinical success of pacing was observed in 13/16 patients = 81%. The pacemaker proved to be a versatile system with reliable tachycardia detection and termination functions.  相似文献   

12.
This multicenter study reports the outcome of ventricular tachycardia (VT) therapy (conversion or acceleration) and the relationship to initial tachycardia cycle length and other clinical variables using an implantable device with the capability of autodecremental or burst pacing, Cardioversion, and defibrillation. The device was implanted in 444 patients (mean age 58 ± 15 years) with 1,240 episodes of VT induced with noninvasive programming and reported in a multicenter database. Only the first sequence attempted for conversion by pacing or Cardioversion was assessed, and Cardioversion energies were 0.2–5 J. Autodecremental pacing was used to treat 700 induced episodes of VT during titration of pacing therapies (57% converted and 12% accelerated), burst pacing to treat 357 episodes (49% converted and 11% accelerated), and Cardioversion to treat 183 episodes (82% converted and 4% accelerated). Cardioversion was the most effective treatment and had the lowest acceleration rate. Shorter VT cycle lengths were more likely to accelerate with burst pacing and longer VT cycle lengths to convert with both burst and autodecremental pacing. Patients with higher ejection fractions were more likely to convert with autodecremental and burst pacing. Use of Cardioversion, higher ejection fraction, absence of unrepaired aneurysm, longer VT cycle lengths, coronary artery disease, and use of autodecremental pacing predicted conversion. Lower ejection fraction and VT cycle lengths ± 300 msec predicted tachycardia acceleration.  相似文献   

13.
Eighty-six patients were treated with an implantable cardioverter defibrillator (ICD) because of sustained ventricalar tachycardia (VT) or ventricular fibrillation (VF). In 27 patients an epicardial system was used, in 59 patients a transvenous system with a subcutaneous patch electrode was implanted. During a mean follow-up time of 17 ± 9 months, inappropriate activations of the ICD due to supraventricular tachycardia were documented by Holter monitoring in 14 patients (16%). In 8 patients paroxysmal atrial fibrillation (AF), in 2 patients chronic AF, in 1 patient atrial flutter, and in 3 patients sinus tachycardia triggered antitachycardia pacing functions (12 patients) or internal defibrillation (2 patients). In 3 patients (5%) VT was induced by inappropriate antitachycardia pacing. In an additional 18 patients (21%) inappropriate activation of antitachycardia functions due to atrial tachyarrhythmias were suspected based on telemetry readouts or the patient's history. Inappropriate activation of ICD therapy triggered by intermittent supraventricular tachyarrhythmias is common. Further improvements of detection algorithms for supraventricular tachycardia are required in future device generations.  相似文献   

14.
In order to evaluate the potential use of external cardiac pacing (EXP) in the clinical termination of sustained ventricular tachycardia (VT), we attempted VT terminations in seven patients. All had recurrent sustained monomorphic ventricular tachycardia (mean rate 145 beats/min), which had previously required cardioversion. During subsequent VT episodes, all seven underwent overdrive pacing with EXP at a pulse amplitude of 120 mA, and rates of 200 pulses/min. A total of 18 of 18 episodes of VT were successfully terminated by EXP alone. In one patient, the first attempt at EXP termination of one episode of VT resulted in an acceleration of the tachycardia, which was then terminated by EXP. All patients tolerated EXP well with minimal sedation. We conclude that EXP may be an effective clinical modality for the termination of sustained monomorphic ventricular tachycardia.  相似文献   

15.
Advances in cardiac electrophysiology have clarified some of the mechanisms of tachydysrhythmias and have characterized tachycardias that are amenable to pace termination. Tachydysrhythmias most likely to be terminated by pacing techniques tend to be slow, re-entrant tachycardias. Although single extrastimulation can be effective, its yield is relatively low. Delivery of multiple extrastimuli or burst pacing are more effective than single extrastimulation at the expense of a higher risk of tachycardia acceleration or transformation of the rhythm to fibrillation. The use of pacing for the termination of tachydysrhythmias has primarily been limited to the acute care setting, although permanently implantable antitachycardia pacemakers are being used in increasing numbers. While these devices have been approved by the Food and Drug Administration (FDA) for the treatment of supraventricular tachydysrhythmias, their use to treat ventricular tachydysrhythmias has produced mixed results and remains investigational. In some cases of sustained ventricular tachycardia, automatic cardioverter/defibrillators have been implanted along with antitachycardia pacemakers to provide high-energy shock back-up in case of tachycardia acceleration by the pacemaker. Soon, devices will be available which will combine, in a single unit, antitachycardia pacing and high-energy cardioversion/defibrillation.  相似文献   

16.
Background: With the development of left ventricular pacing for cardiac resynchronization, there is an interest in the possibility of improving ventricular antitachycardia pacing (ATP) efficacy by pacing from the LV electrode(s).
Objective: This study assessed the efficacy of pacing delivered from the left coronary vein (LCV) compared to that delivered from the right ventricular apex (RVA) upon ventricular tachycardia (VT) induction and termination.
Methods: Sixty patients undergoing provocative ventricular electrophysiology (EP) studies in three centers were enrolled. Multipolar EP catheters were placed in the atrium, the RVA, and LCV. VT induction was attempted from the RVA and LCV in random order. Upon detection of monomorphic VT, burst ATP for up to 10 pulses at 88% VT cycle length was delivered from the RVA or LCV, in a random order, and crossed over when possible. Identical VT morphologies were reinduced to allow paired comparison of RVA versus LCV ATP.
Results: Data from 55 patients were analyzed. Thirty-four morphologically distinct monomorphic VT types were induced in 22 patients. ATP succeeded in 18 (55%) and VTs in 13 patients. RVA ATP terminated 15 of 23 (65%) VTs, and LCV ATP terminated 10 of 23 (43%) VTs (P = 0.14). ATP delivered ipsilateral to the earliest activation site required 5.0 ± 2.6 pulses to terminate compared to 4.8 ± 1.7 pulses when delivered from the contralateral site (P = 0.90). Paired comparison was possible for 13 VT morphologies in 11 patients. Paired RVA and LCV ATP efficacy was identical (54 % vs 54%, P = 1.0).
Conclusion: ATP delivered from a LCV lead offers no efficacy advantage over pacing from the RVA. (PACE 2010; 27–32)  相似文献   

17.
Third-generation implantable cardioverter defibrillators (ICDs) offer tiered therapy and can provide significant advantage in the management of patients with life-threatening arrhythmias. Three different types of ICDs were implanted in 21 patients with ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia presentation was VT(76%), VF(10%), or both (14%). The mean left ventricular ejection fraction for the group was 32.4 ± 7%. No surgical mortality occurred. Prior to discharge individual EPS determined the final programmed settings of the ICDs. During a mean follow-up of 13 ± 1.4 months (range 2–20) the overall patient survival was 85.7%. No sudden arrhythmic or cardiac death occurred. Twenty of 21 patients (95%) received therapy by their device. In 14 patients (67%) antitachycardia pacing (A TP) was programmed "on," 13 of which was self-adaptative autodecremental mode. There were 247 VT episodes, 231 of which were subjected to ATP with 97% success and 3% acceleration or failure. Low energy shocks reverted all other VT episodes. VF episodes were successfully reverted by a single shock (93%), two shocks (6%), or three shocks (1 %). We conclude that ATP therapy of VT is successful in the large majority of episodes with rare failures, and that VF episodes are generally terminated by a single ICD shock.  相似文献   

18.
The objective of this study was to compare prospectively the efficacy of fixed burst pacing with that of decremental hurst pacing in terminating VT. Forty-four patients with inducible sustained monomorphic VT were studied. The efficacy of fixed burst and decremental burst pacing in terminating 57 distinct types of VT were compared during 50 eiectrophysiology tests fmean VT cycle length = 334 ± 84 msec. Termination of each type of VT was attempted with fixed burst and decremental burst pacing, Both pacing algorithms were delivered in an adaptive fashion with an increasing number of stimuli with each successive attempt at VT termination. Seventy percent of VT episodes were successfully terminated with fixed burst pacing, The mean number of stimuli required for VT termination was 5 ± 2. Seventy-two percent of VT episodes were successfully terminated with decremental burst pacing. The mean number of stimuJi required for VT termination ivas 5 ± 2. For fixed burst and decremental burst pacing, the efficacy of VT termination was greater for VTs with a cycle length > 300 msec than for faster VTs (P < 0.05). The efficacy of VT termination and the incidence of VT acceleration were no different for the two pacing algorithms (P > 0.1). The results of this study demonstrate that fixed burst and decrementai burst pacing are equally effective in terminating VT and that a single adaptive pacing algorithm is effective in terminating nearly three fourths of VTs.  相似文献   

19.
The efficacy of antitachycardia pacing (ATP) incorporated into implantable cardioverter defibrillators (ICDs) was assessed in 29 consecutive survivors of cardiac arrest, not attributable to acute myocardial infarction, ischemia, or drug and electrolyte effects. The cohort included 25 men and 4 women with a mean age of 65 years and a mean left ventricular ejection fraction of 29%. Seventeen patients had coronary artery disease, 11 had nonischemic dilated cardiomyopathy, and 1 had long QT syndrome. Programmed stimulation yielded monomorphic ventricular tachycardia (VT) in 17 patients, polymorphic VT in 6, and no inducible VT in 6. During a mean follow-up of 22 months, a total of 91 episodes of monomorphic VT occurred, 73 of which were successfully pace terminated (83%). Monomorphic VT amenable to pace termination recurred only in the group that had this arrhythmia inducible. The recurrent arrhythmias in the 12 patients having either no inducible VT or polymorphic VT were all rapid VTs, having a cycle length < 220 ms; and therefore, not amenable to pace termination. These results suggest that ATP incorporated into ICDs is useful in survivors of cardiac arrest and may significantly reduce the number of shocks that these patients would otherwise receive. Programmed stimulation may also help to define those patients who would receive the maximum benefit from ATP.  相似文献   

20.
GIROD, J.P., et al. : Moricizine Induced Increase in Pacing Threshold. A 72-year-old woman who was experiencing incessant ventricular tachycardia and recurrent automatic implantable cardioverter defibrillator (AICD) firing despite amiodarone therapy was referred to the Cleveland Clinic Foundation. Myocardial ischemia and infarction were ruled out by standard means. Several antiarrhythmic medications were tried previously without success. Moricizine, 200 mg three times daily, was initiated and controlled the ventricular tachycardia. However, after the dose of moricizine was titrated upward, the patient became symptomatically bradycardic and the ECG exhibited 2:1 block of her paced rhythm and an increased ventricular pacing threshold. (PACE 2003; 26[Pt. I]:110–111)  相似文献   