共查询到20条相似文献,搜索用时 15 毫秒
1.
A spontaneous abdominal aortic dissection is very rare. We experienced this rare entity in a 37-year-old man. He was successfully treated by endovascular stent grafting, including coil embolization of the inferior mesenteric artery. The pseudolumen was completely thrombosed and it shrank without any endoleak 3 months later. This modality is thus considered to be a good alternative to open surgical repair, even though a long-term follow-up is mandatory. 相似文献
2.
3.
A 66-year-old man with an abdominal aortic aneurysm previously repaired with an endovascular stent graft presented to our facility with worsening midabdominal and back pain. Previous postoperative surveillance computed tomography scans were unremarkable, showing excellent stent-wall apposition and a shrinking aneurysm sac; however, imaging done on his arrival identified a contained rupture at the level of the celiac artery containing a perforating suprarenal stent. We repaired this rupture with a surgeon-modified fenestrated stent graft. To our knowledge, this is the first reported case of penetration of the native aorta by a suprarenal stent in the absence of infection or trauma. 相似文献
4.
《Journal of vascular surgery》1998,28(1):184-187
We describe a case of abdominal aortic aneurysm (AAA) with rupture 16 months after treatment by an endograft. A 76-year-old patient on Coumadin after aortic valve replacement had initially successful exclusion by stentgraft. There was no evidence of an endoleak seven months after stentgraft repair, although a computed tomography scan detected an enlargement of the aneurysm sac. Sixteen months after initial endograft surgery, rupture of the aneurysm occurred and we performed open emergency surgery. We treated the aneurysm by conventional technique, and the patient survived the rupture. This case emphasized the fact that patients after endograft AAA repair require a close follow-up. An expansion of the aneurysm sac after the procedure should signal failed exclusion, even if a computed tomography scan does not demonstrate an endoleak. Anticoagulation can be an important factor in failure after endoluminal graft treatment. Supravisceral aortic cross clamping is helpful in dealing with a stented aorta. (J Vasc Surg 1998;28:184-7.) 相似文献
5.
A case of mycotic aneurysm of the abdominal aorta, arising as a complication of subacute bacterial endocarditis in a 75-year-old white woman, is presented. The dramatically expansile nature of this aneurysm is well documented. The history, clinical presentation, etiology, microbiology and surgical management of this rapidly progressive and often fatal condition are discussed through a review of the literature. 相似文献
6.
Abdominal aortic aneurysm (AAA) is distinctly uncommon in infants and children, and usually results from infection, iatrogenic trauma, vasculitis, connective tissue disorder, or tuberous sclerosis. Congenital "primary" neonatal AAA is exceedingly rare. The few reported cases of repair of congenital AAA describe use of synthetic graft material or aneurysmorrhaphy. We report the first successful treatment of a known 6 cm congenital infrarenal AAA repaired with a 5 mm cryopreserved allograft in a 4-month-old infant girl. The graft was pretreated with an antigen reduction process (SynerGraft), which preliminary studies suggest may inhibit allograft degeneration. The postoperative course was unremarkable. Lower extremity pulses and results of duplex ultrasound flow studies remained excellent at 14-month follow-up. Panel reactive antibodies against class I alloantigens remain negative. The use of an antigen-reduced allograft provides an acceptable conduit, which potentially may decrease allograft degeneration and relative graft stenosis associated with growth of the child, but requires follow-up. 相似文献
7.
Stein DE DiMuzio PJ Cohen MJ Carabasi RA Bonn J Kahn MB 《Vascular and endovascular surgery》2002,36(3):219-222
Endograft repair has rapidly become an alternative to conventional open repair of abdominal aortic aneurysms. Various trials continue to show decreased morbidity when compared to open repair. However, as with any new procedure, complications specifically related to this technique are being described. Herein, we report a case of an isolated ischemic jejunal stricture presenting as a small-bowel obstruction secondary to cholesterol emboli following endograft repair of an abdominal aortic aneurysms. 相似文献
8.
Melissano G Moura MR Tshomba Y Marone EM Chiesa R 《Vascular and endovascular surgery》2003,37(4):283-287
The successful endovascular exclusion of a ruptured 3-cm diameter atherosclerotic abdominal aortic aneurysm (AAA) in a high-risk patient with renal failure is reported. An 82-year-old man with chronic renal failure and other comorbidities was admitted for acute abdominal pain. Duplex scan and computed tomography showed a ruptured 3-cm diameter atherosclerotic AAA. As a consequence of the patient's high surgical risk combined with signs of rupture, despite the progressively decreasing renal function, an emergency exclusion of the AAA was performed by means of a bifurcated Excluder (W. L. Gore and Associates) endovascular graft. The procedure was performed by minimizing administration of iodinated contrast medium using a guidewire into the lowest renal artery as a marker of proximal deployment. Intravascular ultrasound was used to confirm correct deployment. The postoperative recovery was characterized by acute renal insufficiency and bowel ischemia, which were treated with ultrafiltration and medical therapy, respectively, with complete resolution. 相似文献
9.
Prosthetic stent graft infection after endovascular abdominal aortic aneurysm repair 总被引:10,自引:0,他引:10
Sharif MA Lee B Lau LL Ellis PK Collins AJ Blair PH Soong CV 《Journal of vascular surgery》2007,46(3):442-448
OBJECTIVE: The purpose of this report is to discuss the incidence, diagnosis, and management of stent graft infections after endovascular aneurysm repair (EVAR). METHODS: Data were collected from the hospital database and medical case notes for all patients with infected endografts after elective or emergency EVAR for abdominal aortic aneurysm (AAA) during the last 8 years in two university teaching hospitals in Northern Ireland. The data included the patient's age, gender, presentation of sepsis, treatment offered, and the ultimate outcome. The diagnosis of graft-related sepsis was established by a combination of investigations including inflammatory markers, labelled white cell scan, computed tomography (CT) scan, microbiology cultures, and postmortem examination. RESULTS: Graft-related septic complications occurred in six of 509 patients, including 433 elective repairs and 76 emergency endografts for ruptured AAA. Two patients presented with left psoas abscess and were treated successfully with extra-anatomic bypass and removal of the infected stent graft. Two more patients presented with infected graft without other evidence of intra-abdominal sepsis: one underwent successful removal of the infected prosthesis with extra-anatomical bypass, and the other was treated conservatively and died of progressively worsening sepsis. The fifth patient presented with unexplained fever and died suddenly, with a postmortem diagnosis of aortoenteric fistula and ruptured aneurysm. The last patient presented with an aortoenteric fistula, was treated conservatively in view of concurrent myelodysplasia, and died of possible aneurysm rupture. CONCLUSION: This report emphasizes the need for continued awareness of potential graft-related septic complications in patients undergoing EVAR of AAA. Attention to detail with regard to sterility and antibiotic prophylaxis during stent grafting and during any secondary interventions is vital in reducing the risk of infection. In addition, early recognition and prompt treatment are essential for a successful outcome. 相似文献
10.
11.
12.
13.
14.
Inflammatory abdominal aortic aneurysm 总被引:1,自引:0,他引:1
The inflammatory abdominal aortic aneurysm has received little attention in the literature. To date only four reports have addressed the subject specifically. Controversy remains as to whether this is a variant of the usual atherosclerotic aneurysm or a separate entity. The operative reports of 24 patients with inflammatory abdominal aortic aneurysms are reviewed; 21 were intact and 3 ruptured. Intact aneurysms ranged in diameter from 5 to 12 cm and the ruptured ones from 5 to 10 cm. Nine patients with intact aneurysms had symptoms of abdominal or back pain. Of 13 patients who underwent excretory pyelography before operation, only 3 had evidence of obstruction. Nine patients had tube grafts placed, 10 had aortoiliac grafts and 5 aortofemoral grafts. There was one intraoperative duodenal injury and in another patient it was necessary to divide the left renal vein for proximal exposure. No attempt was made to expose the ureters at operation. All patients were discharged from hospital. The authors believe that the inflammatory aneurysm is a variant of the abdominal aortic arteriosclerotic aneurysm. Intraoperative complications can be avoided by the recognition of the pathological features. 相似文献
15.
Yoshinaga K Yoshida R Guntani A Matsumoto T Saeki H Morita M Emi Y Kakeji Y Tsujitani S Maehara Y 《Surgery today》2011,41(5):721-725
We herein present the case of a 66-year-old man with both gastric cancer and an infrarenal abdominal aneurysm. The patient’s
medical history included bladder cancer, chronic renal failure, and ischemic heart disease. We performed a simultaneous endovascular
aneurysm repair (EVAR) and total gastrectomy. Following the procedure, the patient remained in the intensive care unit for
3 days. Oral feeding was resumed on postoperative day 7, and the patient was discharged from the hospital on postoperative
day 13 with no complications. Despite the patient’s medical problems and higher operative risk, he tolerated simultaneous
EVAR and total gastrectomy, and had a good outcome after undergoing these simultaneous procedures. 相似文献
16.
《Journal of vascular surgery》1998,28(2):349-352
Transluminal placement of a stent graft in patients with an abdominal aortic aneurysm is a new endovascular technique that offers a potentially less invasive and less risky alternative to open surgery. Complications after stent graft placement are not infrequent, but in most cases secondary endovascular intervention is successful. We describe a late major leak in the aneurysmal sac caused by a distal migration of the iliac limb of a bifurcated graft. This late complication was successfully treated by covered stent placement, excluding and thrombosing completely the reformed aneurysm. (J Vasc Surg 1998;28:349-352) 相似文献
17.
Yamashita A Ishida K Aratake K Wakamatsu H Kawata R Kunihiro M Sakabe T 《Masui. The Japanese journal of anesthesiology》2000,49(9):987-994
We retrospectively examined the changes in hemodynamics, oxygen index and renal function along with the complications in 25 patients who had undergone endovascular stent graft placement (ESG) surgery for abdominal aortic aneurysm. During stent graft placement, mean arterial pressure decreased to 58 +/- 8 mmHg by increasing the dose of anesthetics and/or using vasodilators. Except for this intended hypotensive period, mean arterial pressure and heart rate were relatively stable and adequately maintained during surgical manipulation. Oxygenation index was well maintained. A patient with a high preoperative creatinine level underwent prophylactic hemodialysis postoperatively. In other patients except one who died in early postoperative period, both BUN and creatinine levels were kept within normal ranges. Four patients died postoperatively and the causes of the death in two patients are related to the surgical procedure; one with multiple emboli possibly due to released atheloma from the aortic wall during procedure, the other with sepsis due to infected stent graft. Although ESG is a well tolerated procedure, embolism is the most serious complication. Careful preoperative evaluation of the ascending arch and descending aortic wall and monitoring with transcranial doppler are necessary. 相似文献
18.
19.
20.
Effective endovascular repair of an infrarenal abdominal aortic aneurysm (AAA) requires adequate proximal and distal landing zones to allow secure endograft attachment. We report a patient with an infrarenal AAA originating 3 mm below the left renal artery with cardiac morbidity that precluded open AAA repair. Left renal artery relocation with retroperitoneal iliorenal bypass grafting was performed to lengthen the proximal landing zone, which facilitated successful endovascular AAA repair. Postoperative surveillance after 3 years showed aneurysm reduction with a patent iliorenal bypass graft. This case underscores the utility of a combined open and endovascular approach in treatment of a challenging aortic aneurysm. 相似文献