首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In a study to determine the reliability, sensitivity, and specificity of the Chiron RIBA HIV-1/HIV-2 Strip Immunoblot Assay (RIBA HIV-1/2 SIA) for confirmation of human immunodeficiency virus type 1 (HIV-1) and HIV-2 antibodies, 1,263 serum samples from various populations in the United States, Caribbean, Africa, India, and Thailand were evaluated by RIBA HIV-1/2 SIA, and the results were compared with those obtained by an HIV-1 Western blot (immunoblot) assay. All sera were tested by HIV enzyme immunoassay, RIBA HIV-1/2 SIA, and Western blotting. Samples with discrepant results were further tested by an HIV-1 and/or HIV-2 immunofluorescent-antibody assay and HIV-1 p24 antigen assay. The RIBA HIV-1/2 SIA detected all 17 HIV-1 and HIV-2 dually reactive serum samples, all 215 HIV-2-positive serum samples, and 480 of 481 HIV-1-positive serum samples for a sensitivity of 99.8%. Of 548 negative samples, 523 were RIBA HIV-1/2 SIA negative, for a specificity of 95.4%, with 22 (4%) samples interpreted as indeterminate and 3 (0.6%) interpreted as falsely positive. Western blotting detected 391 of 548 negative samples (specificity, 71.4%), with 152 (27.7%) samples interpreted as indeterminate and 5 (0.9%) interpreted as falsely positive. In conclusion, the RIBA HIV-1/2 SIA had a sensitivity comparable to that of Western blotting and could discriminate HIV-1 from HIV-2 in one blot, providing a cost advantage. Because of its high degree of specificity, the RIBA HIV-1/2 SIA further reduced the number of indeterminate results found by Western blotting, providing a more accurate means of assessing seronegative individuals.  相似文献   

2.
Serum specimens were collected from 31,232 pregnant women in Amsterdam between 1988 and 1995 in a screening programme for human deficiency virus (HIV) infection. The sera of 56 (0.179%) women tested were confirmed as positive for HIV. A total of 67 sera reacted positive or borderline by the screening enzyme-linked immunosorbent assay (ELISA) and indeterminate or negative by HIV-1 Western blot; 42 of these specimens were available for evaluation of the strategy for diagnosis of HIV infection. A two-ELISA approach with the second ELISA based on a principle different from that of the screening ELISA, expanded with the use of a membrane immunoassay based on two synthetic peptides specific for HIV-1 gp41 and HIV-2 gp36 envelope proteins, was compared with the Western blot analysis. Indeterminate results were resolved with a nucleic acid sequence-based amplification assay (NASBA) for HIV-1 RNA and a strip immunoassay (SIA) for the simultaneous detection of antibodies to HIV-1 or HIV-2 and HIV-1 p24 antigen. Eleven samples were weakly or borderline positive by the screening test and gave indeterminate results by Western blot. The expanded two-ELISA approach designated these sera as HIV-negative, and confirmed negative by NASBA and the SIA. Twenty-one samples showed borderline or positive results on the screening test and negative results by Western blot. Again, these sera were characterised as HIV-negative by the expanded two-ELISA procedure, and this characterisation was confirmed by both NASBA and the SIA. Five HIV-2-positive serum samples were recognised by the expanded two-ELISA approach and the SIA; these sera were negative by NASBA. Finally, another five serum samples were weakly or borderline positive by both ELISAs and positive by the membrane immunoassay; of these five, two sera generated positive patterns and the other three indeterminate patterns on Western blots, and four were positive by the NASBA assay. Follow-up serum specimens from these five women were negative and the reactivity of the initial specimens was thus likely to have been the result of cross-contamination. Our results demonstrate the effectiveness of a simple confirmation approach of two HIV ELISAs expanded with a membrane spot assay to discriminate between infection with HIV-1 or HIV-2. The data also indicate the importance of retesting individuals with indeterminate or positive confirmational results to exclude the possibility of contamination as the cause of reactivity of the original specimen. J. Med. Virol. 54:285–290, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

3.
BackgroundA new HIV diagnostic algorithm has been proposed which replaces the use of the HIV-1 Western blot and HIV-1 immunofluorescence assays (IFA) as the supplemental test with an HIV-1/HIV-2 antibody differentiation assay.ObjectivesTo compare an FDA-approved HIV-1/HIV-2 antibody differentiation test (Multispot) as a confirmatory test with the HIV-1 Western blot and IFA.Study designParticipants were screened with an HIV-1/HIV-2 combination Antigen/Antibody (Ag/Ab) screening assay. Specimens with repeatedly reactive results were tested with Multispot and either Western blot or IFA. Specimens with discordant screening and confirmatory results were resolved with HIV-1 RNA testing.ResultsIndividuals (37,876) were screened for HIV infection and 654 (1.7%) had a repeatedly reactive Ag/Ab assay result. On Multispot, 554 (84.7%) were HIV-1 reactive, 0 (0%) were HIV-2 reactive, 1 (0.2%) was reactive for both HIV-1 and HIV-2 (undifferentiated), 9 (1.4%) were HIV-1 indeterminate, and 90 (13.8%) were non-reactive. HIV-1 RNA was detected in 47/90 Multispot non-reactive (52.2%) specimens. Among specimens confirmed to have HIV infection (true positives), Multispot and Western blot detected HIV-1 antibody in a similar proportion of cases (93.7% vs. 94.4% respectively) while Multispot and IFA also detected HIV-1 antibody in a similar proportion of cases (84.5% vs. 83.4% respectively).ConclusionsIn this study, Multispot confirmed HIV infections at a similar proportion to Western blot and IFA. Multispot, Western blot, and IFA, however, did not confirm all of the reactive Ag/Ab assay results and underscores the importance of HIV NAT testing to resolve discordant screening and confirmatory results.  相似文献   

4.
To identify a major antigenic determinant for use in the development of a rapid serological diagnostic test for severe acute respiratory syndrome (SARS) coronavirus infection and to study the immune response during SARS coronavirus infection in humans, we cloned the full length and six truncated fragments of the nucleocapsid gene, expressed them, and purified them as glutathione S-transferase-tagged recombinant proteins. The reactivities of the recombinant proteins to a panel of antibodies containing 33 SARS coronavirus-positive sera and 66 negative sera and to antibodies against other animal coronaviruses were screened. A truncated 195-amino-acid fragment from the C terminus of the nucleocapsid protein (N195) was identified that had a strong ability to detect antibodies against SARS coronavirus. No cross-reaction was found between the N195 protein and antibodies against chicken, pig, and canine coronaviruses. The N195 protein was used to develop a Western blot assay to detect antibodies against SARS coronavirus in 274 clinically blinded samples. The specificity and sensitivity of this test were 98.3 and 90.9%, respectively. The correlation between our Western blotting assay and an immunofluorescence assay (IFA) was also analyzed. The results of our Western blot assay and IFA for the detection of SARS coronavirus-positive sera were the same. Thus, the N195 protein was identified as a suitable protein to be used as an antigen in Western blot and other possible assays for the detection of SARS coronavirus infection.  相似文献   

5.
To identify a major antigenic determinant for use in the development of a rapid serological diagnostic test for severe acute respiratory syndrome (SARS) coronavirus infection and to study the immune response during SARS coronavirus infection in humans, we cloned the full length and six truncated fragments of the nucleocapsid gene, expressed them, and purified them as glutathione S-transferase-tagged recombinant proteins. The reactivities of the recombinant proteins to a panel of antibodies containing 33 SARS coronavirus-positive sera and 66 negative sera and to antibodies against other animal coronaviruses were screened. A truncated 195-amino-acid fragment from the C terminus of the nucleocapsid protein (N195) was identified that had a strong ability to detect antibodies against SARS coronavirus. No cross-reaction was found between the N195 protein and antibodies against chicken, pig, and canine coronaviruses. The N195 protein was used to develop a Western blot assay to detect antibodies against SARS coronavirus in 274 clinically blinded samples. The specificity and sensitivity of this test were 98.3 and 90.9%, respectively. The correlation between our Western blotting assay and an immunofluorescence assay (IFA) was also analyzed. The results of our Western blot assay and IFA for the detection of SARS coronavirus-positive sera were the same. Thus, the N195 protein was identified as a suitable protein to be used as an antigen in Western blot and other possible assays for the detection of SARS coronavirus infection.  相似文献   

6.
目的:研制禽流感病毒H7亚型血凝素特异性单克隆抗体(mAb)。方法:以H7亚型禽流感诊断抗原为免疫原免疫6~8周雌性BALB/c小鼠,末次加强免疫后取其脾细胞与骨髓瘤细胞Sp2/0-Ag-14进行融合。通过HA和HI试验筛选阳性克隆。应用HI试验和Western blot试验测定mAb的反应性和特异性。结果:共获得4株分泌抗AIVH7亚型HAmAbs的杂交瘤细胞株,分别命名为2E2、2A4、5F5、7G5。这些mAb的腹水HI效价在5×27~5×211之间,其中2E2属于IgM亚类,2A4属于IgG1亚类,5F5、7G5属于IgG2a亚类。Western blot分析结果显示,4株AIVH7亚型HAmAb能与AIVH7蛋白在Mr75000处反应,但不与新城疫病毒(NDV)蛋白发生反应,表明这些mAb能特异性识别AIVH7亚型HA。mAbHI反应性测定结果表明:4株mAb中,2E2、5F5、7G5只与H7亚型AIV发生特异性HI反应,而不与其他亚型AIV以及NDV、传染性支气管炎病毒(IBV)反应,显示出良好的特异性;而2A4除了与H7亚型AIV反应外,还与H15N8标准株发生低水平交叉反应。结论:这些mAb不仅为H7亚型AIV的HA结构分析提供了工具,而且为建立快速廉价的H7亚型禽流感诊断方法提供了核心试剂。  相似文献   

7.
An epitope-blocking enzyme-linked immunosorbent assay (bELISA) was developed for the detection of antibodies to influenza A virus in taxonomically diverse domestic and wild vertebrate species. In contrast to the bELISAs published previously that require reagent production, manipulation by the end-user, or have not been evaluated for use with both mammalian and avian species, this assay is performed using commercially available recombinant nucleoprotein antigen and corresponding nucleoprotein-specific monoclonal antibody and has been shown to work with multiple avian and mammalian species. The efficacy of the bELISA as a serum screening assay was compared to the agar gel immunodiffusion (AGID) assay using 251 serum samples obtained from experimentally infected mallards (Anas platyrhynchos) and raccoons (Procyon lotor). The concordance between the AGID assay and bELISA was 94.1% (95% CI = 89.9, 98.3) for raccoons, and 71.2% (95% CI = 63.5, 78.9) for mallards and 82.8% (95% CI = 78.2, 87.3) overall. The bELISA was more sensitive than the AGID assay as demonstrated by the detection of antibodies to influenza A virus at earlier time points in experimental infection studies and at higher serial dilutions. The efficacy of the bELISA to monitor natural influenza A virus exposure was also compared to the AGID assay using an additional 745 serum samples from six avian species and six mammalian species. This bELISA provides a rapid, reliable, and inexpensive technique for large-scale surveillance of influenza A virus exposure in taxonomically diverse vertebrate species.  相似文献   

8.
The control of equine infectious anemia virus (EIAV) infections of horses has been over the past 20 years based primarily on the identification and elimination of seropositive horses, predominantly by a standardized agar gel immunodiffusion (AGID) assay in centralized reference laboratories. This screening for EIAV-seropositive horses has been to date hindered by the lack of a rapid diagnostic format that can be easily employed in the field. We describe here the development of a rapid solution-phase assay for the presence of serum antibodies to EIAV based on fluorescence polarization (FP) (patent pending). Peptides derived from antigenic regions of EIAV core and envelope proteins were initially screened for their utility as probes in an FP assay to select the best peptide antigen candidates. The FP assay was optimized to detect the presence of EIAV-specific antibodies by a change in the FP of a fluorescein-labeled immunoreactive peptide diagnostic antigen. The most sensitive and specific peptide probe was a peptide corresponding to the immunodominant region of the EIAV transmembrane protein, gp45. This probe was tested for its reactivity in the optimized FP assay with 151 AGID-positive horse sera and 106 AGID-negative serum samples. The results of these studies demonstrated that the FP assay reactivity correlated with reported AGID results in 106 of 106 negative serum samples (100% specificity) and in 135 of 151 positive serum samples (89.4% sensitivity). The FP assay was also found to have a very low background reactivity and to readily detect antibodies produced early in infection (相似文献   

9.
A competitive-inhibition enzyme-linked immunosorbent assay (cELISA) for detection of antibodies to the surface envelope (SU) of caprine arthritis-encephalitis virus (CAEV) was recently reported (L. M. Herrmann, W. P. Cheevers, T. C. McGuire, D. Scott Adams, M. M. Hutton, W. G. Gavin, and D. P. Knowles, Clin. Diagn. Lab. Immunol. 10:267-271, 2003). The cELISA utilizes CAEV-63 SU captured on microtiter plates using the monoclonal antibody (MAb) F7-299 and measures competitive displacement of binding of the anti-CAEV MAb GPB 74A by goat serum. The present study evaluated the CAEV cELISA for detection of antibodies to ovine progressive pneumonia virus (OPPV) in sheep. Three hundred thirty-two sera were randomly selected from 21,373 sheep sera collected throughout the United States to determine the sensitivity and specificity of cELISA and agar gel immunodiffusion (AGID) based on immunoprecipitation (IP) of [35S]methionine-labeled OPPV antigens as a standard of comparison. A positive cELISA test was defined as >20.9 percent inhibition (% I) of MAb 74A binding based on two standard deviations above the mean % I of 191 IP-negative sheep sera. At this cutoff, there were 2 of 141 false-negative sera (98.6% sensitivity) and 6 of 191 false-positive sera (96.9% specificity). Sensitivity and specificity values for IP-monitored AGID were comparable to those for cELISA for 314 of 332 sera with unambiguous AGID results. Concordant results by cELISA and IP resolved 16 of the 18 sera that were indeterminate by AGID. Additional studies evaluated cELISA by using 539 sera from a single OPPV-positive flock. Based on IP of 36 of these sera, there was one false-negative by cELISA among 21 IP-positive sera (95.5% sensitivity) and 0 of 15 false-positives (100% specificity). We conclude that the CAEV cELISA can be applied to detection of OPPV antibodies in sheep with high sensitivity and specificity.  相似文献   

10.
Tests for the detection of antibodies to Treponema pallidum are recommended for the confirmation of reactive nontreponemal test results and the accurate diagnosis of syphilis. The present-day use of Western blot (immunoblot) technology for the diagnosis of retroviruses prompted the development and evaluation of a Western blot assay with whole-cell T. pallidum as the antigen. The assay detected antibodies in syphilitic serum or plasma from dilutions of specimens incubated overnight with test strips. A test was considered positive when at least three of four major antigens having molecular masses of 15.5, 17, 44.5, and 47 kDa were detected. The Western blot assay had 93.8% sensitivity and 100% specificity for clinically defined samples. The Western blot assay was compared with double-staining fluorescent treponemal antibody absorption [FTA-ABS (DS)], which had a sensitivity and a specificity of 91.7 and 92.0%, respectively. Dilution series studies of syphilis-positive specimens indicated that the Western blot assay has an endpoint of reactivity at least 3 to 4 serial dilutions greater than that for FTA-ABS (DS). Overall, the greater than 95% agreement between the Western blot assay and FTA-ABS (DS) for clinically defined specimens indicates that the sensitivity of the Western blot assay is equal to or greater than that of FTA-ABS (DS). The Western blot assay demonstrated no false-positive or equivocal reactivities for nonsyphilitic specimens, including normal specimens (both plasma and serum), biological false-positives, and specimens with elevated gamma globulin or antinuclear antibody. We conclude that the high sensitivity and specificity of the T. pallidum Western blot assay, together with its simplicity and objectivity, make it a good confirmatory test for syphilis.  相似文献   

11.
Many truly human immunodeficiency virus (HIV) antibody-negative serum samples may be unnecessarily subjected to costly and time-consuming Western blots (immunoblots). An investigation was undertaken to evaluate the efficiency of using a recombinant protein-based enzyme immunosorbent assay (EIA; Cambridge BioScience [CBC] Recombigen HIV EIA) as an adjunct to whole viral lysate EIA. A total of 2,212 serum samples which had been screened by viral lysate EIA were tested by CBC EIA in parallel with the Western blot. The sensitivity and specificity of the CBC kit were 99.9 and 99.7%, respectively. Positive and negative predictive values were 99.7 and 99.9%, respectively. The high sensitivity of this kit and its high negative predictive value make it an attractive addition to an HIV testing algorithm by reducing the number of Western blot tests on truly antibody negative serum samples.  相似文献   

12.
目的:研制抗血小板膜糖蛋白Ⅱb/Ⅲa Fab抗体。方法:通过问接免疫荧光试验和血小板聚集抑制试验,选取鼠源抗血小板糖蛋白Ⅱb/Ⅲa单克隆抗体(mAb P140)。从分泌该mAb的杂交瘤细胞株(P140)中,克隆到抗体轻链基因和重链Fd段基因,构建原核表达重组质粒p3MH/P140x-Fd,并在XLI-Blu菌株中进行表达。采用钴亲和层析法对P140 Fab抗体进行纯化,用SDS-PAGE、ELISA和Western blot等方法,对P140 Fab抗体进行检测,并通过血小板聚集抑制试验,观察P140 Fab抗体的抗栓活性。结果:SDS-PAGE和Western blot表明,纯化的P140Fab抗体的相对分子质量(Mr)约为47000。ELISA的结果显示,P140 Fab抗体可与人血小板特异性结合。在体外ADP诱导的血小板聚集试验中,P140 Fab抗体对血小板聚集的抑制作用成剂量依赖性,IC50的平均值为16.85mg/L。结论:成功地研制出具有抗栓活性的抗血小板膜糖蛋白Ⅱb/Ⅲa的Fab抗体。  相似文献   

13.
BackgroundIn the United States, a new HIV diagnostic algorithm has been proposed that uses an HIV-1/HIV-2 antibody differentiation immunoassay instead of Western blot or immunofluoresence for confirmatory testing.ObjectivesTo evaluate the Multispot HIV-1/HIV-2 Rapid Test (Multispot) as an alternative to Western blot analysis for confirmation of HIV infection.Study designA series of 205 serum and plasma specimens positive for HIV-1 or HIV-2 were used to compare the performance of Multispot to a standard HIV-1 Western blot. Positive samples included 63 specimens from patients > 18 months of age, 33 proficiency survey specimens, and 109 specimens from nine commercial seroconversion and performance panels. In addition, 63 specimens from 51 HIV-exposed, uninfected children  18 months of age in various stages of seroreversion and 192 HIV-negative samples were tested. Specimens were initially screened using a 4th generation HIV Ag/Ab Combo assay.ResultsMultispot readily discriminated between individuals with HIV-1 or HIV-2 infection and those who were uninfected. Of the 205 samples repeatedly reactive by the 4th generation screening assay, infection status was correctly confirmed by Multispot in 83.9% (172/205) compared to 68.8% (141/205) for Western blot. Multispot detected HIV-1 earlier in 27.6% of low-titer antibody specimens called indeterminate by Western blot, and effectively reduced the number of indeterminate results in seroreverting HIV-1 exposed, uninfected infants and for HIV-2 infections misinterpreted as indeterminate or positive by HIV-1 Western blot.ConclusionsMultispot offers speed and simplicity over Western blot and has an excellent performance for differentiation and confirmation of antibodies to HIV-1 and HIV-2.  相似文献   

14.
目的筛选稳定抑制DAPK表达的PC12细胞系,并观察这些细胞系的生长特性。方法设计、合成4条RNA干扰序列,连接到pDsRed1-N1-U6质粒载体上,扩增后提取质粒转染到PC12细胞,并同时转染1株空载质粒作为对照,然后通过G418筛选细胞克隆,建立稳定增殖细胞系,再通过Western blot筛选最为有效的干扰序列,最后用MTT、流式细胞术等检测转染细胞系的生长特性。结果4条干扰序列均已成功转染并筛选出单克隆细胞系,Western blot实验结果证实,4条干扰序列中有3条对DAPK的表达有明显的抑制作用,其中以第2条干扰序列的抑制效果最为明显。结论成功建立稳定增殖和抑制DAPK表达的细胞系。  相似文献   

15.
The aim of this study was to compare a domestic indirect enzyme-linked immunosorbent assay (DI-ELISA) and an in-house agar gel immunodiffusion (AGID) test with a commercial indirect ELISA (CI-ELISA) test for the detection of antibodies to bovine leukaemia virus (BLV). BLV proteins were harvested as described by OIE and used in both the DI-ELISA and AGID tests. Analysis of negative sera showed that consideration of a cutoff equivalent to three times the standard deviation value above the mean value of the negative control sera provided an acceptable specificity and reduced the risk of false positive results for the DI-ELISA test. From 460 serum samples, 425 (92%), 416 (90%) and 435 (94%) sera were found to be negative when using either the CI-ELISA, DI-ELISA or AGID test. Of the six serum samples which yielded suspicious results with the CI-ELISA, four were found to be positive by the DI-ELISA, but all of them were negative by the AGID test. DI-ELISA and AGID tests’ relative (to CI-ELISA) sensitivities were 97% and 86%, respectively. DI-ELISA and AGID tests’ relative (to CI-ELISA) specificities were 84% and 100%, respectively. Comparison of the results from a native breed, Sarabi, with Holstein showed that there is no significant (p?<?0.05) difference in the frequency of enzootic bovine leukosis between the two.  相似文献   

16.
Sensitive assays are required to detect proviral bovine leukemia virus (BLV) in donor cattle used for the in vivo preparation of Australian tick fever vaccines. 5' Taq nuclease assays using 3' minor groove binder DNA probes (TaqManMGB) were developed and compared to conventional PCR assays for sensitive detection of Australian BLV. Seven beef and dairy herds were screened using DNA prepared by a variety of protocols to evaluate these tests. Comparative sensitivities of PCR tests were determined by testing log(10) dilutions of plasmids with inserted BLV sequences. Animals were also screened by the BLV standard agar-gel immunodiffusion test (AGID) and commercial enzyme linked immunosorbent assays (ELISA) for antibodies, and an ELISA for detecting viral antigens expressed (VAE) in lymphocyte cultures. The TaqMan MGB assay based on the pol region was the most sensitive and specific for the detection of BLV. This is the first report of a sensitive BLV 5' Taq nuclease assay.  相似文献   

17.
Of 693,000 volunteer blood donors in Washington, D.C., who were screened for infection with human immunodeficiency virus type 1 (HIV-1) from July 1985 through December 1988, 284 tested positive on both enzyme immunoassay and Western blot assay. To determine the clinical importance of confirmed positive test results in asymptomatic blood donors, we followed 156 donors with positive Western blot assays and 80 donors with positive enzyme immunoassays but negative or indeterminate Western blots at 6-month intervals for a mean of 28 months. As compared with Western blot-negative persons, those with positive Western blots were significantly more likely to be black, male, and first-time donors and to have a history of venereal disease, generalized lymphadenopathy on examination, CD4-cell counts lower than 0.4 x 10(9) per liter, IgG levels higher than 18 g per liter, and antibody to hepatitis B core antigen on initial evaluation. In 17 (11 percent) of the Western blot-positive donors, the disease progressed to Class IV (symptomatic disease), according to the Centers for Disease Control system. CD4 counts below 0.2 x 10(9) per liter, IgA levels above 4 g per liter, abnormal proliferative responses to tetanus toxoid, and positive viral cultures were the strongest predictors of disease progression. Among the 80 donors with repeatedly reactive assay results but either negative or indeterminate Western blot assays, there was no evidence of HIV exposure in their histories, physical examinations, or laboratory evaluations, and manifestations of HIV infection developed in none of them. We conclude that a small number of persons with HIV infection continue to donate blood, despite attempts to exclude them, but that donors who test positive on enzyme immunoassay but persistently negative or indeterminate on Western blot assay probably do not represent a risk for the transmission of HIV.  相似文献   

18.
A competitive-inhibition enzyme-linked immunosorbent assay (cELISA) for detection of antibodies to the surface envelope (SU) of caprine arthritis-encephalitis virus (CAEV) was recently reported (L. M. Herrmann, W. P. Cheevers, T. C. McGuire, D. Scott Adams, M. M. Hutton, W. G. Gavin, and D. P. Knowles, Clin. Diagn. Lab. Immunol. 10:267-271, 2003). The cELISA utilizes CAEV-63 SU captured on microtiter plates using the monoclonal antibody (MAb) F7-299 and measures competitive displacement of binding of the anti-CAEV MAb GPB 74A by goat serum. The present study evaluated the CAEV cELISA for detection of antibodies to ovine progressive pneumonia virus (OPPV) in sheep. Three hundred thirty-two sera were randomly selected from 21,373 sheep sera collected throughout the United States to determine the sensitivity and specificity of cELISA and agar gel immunodiffusion (AGID) based on immunoprecipitation (IP) of [35S]methionine-labeled OPPV antigens as a standard of comparison. A positive cELISA test was defined as >20.9 percent inhibition (% I) of MAb 74A binding based on two standard deviations above the mean % I of 191 IP-negative sheep sera. At this cutoff, there were 2 of 141 false-negative sera (98.6% sensitivity) and 6 of 191 false-positive sera (96.9% specificity). Sensitivity and specificity values for IP-monitored AGID were comparable to those for cELISA for 314 of 332 sera with unambiguous AGID results. Concordant results by cELISA and IP resolved 16 of the 18 sera that were indeterminate by AGID. Additional studies evaluated cELISA by using 539 sera from a single OPPV-positive flock. Based on IP of 36 of these sera, there was one false-negative by cELISA among 21 IP-positive sera (95.5% sensitivity) and 0 of 15 false-positives (100% specificity). We conclude that the CAEV cELISA can be applied to detection of OPPV antibodies in sheep with high sensitivity and specificity.  相似文献   

19.
Recent studies have shown that rapid, instrument-free assays for the detection of antibody to human immunodeficiency virus (HIV) can be as sensitive and specific as enzyme-linked immunosorbent assay (ELISA) for screening of donated blood in developing countries. Currently, however, specimens which test positive on a screening assay must still be confirmed by Western blot (immunoblot), a method which is not feasible in most developing-country laboratories. We examined whether a testing hierarchy which utilizes neither conventional ELISA nor Western blot can be reliably used for screening and confirmation of HIV infection in a high-risk population. In a retrospective analysis of 3,878 specimens which were screened for antibody to HIV in Kinshasa, Zaire, we observed that a testing hierarchy consisting of duplicate HIVCHEK screening assays followed by duplicate Serodia-HIV confirmatory assays resulted in correct confirmation of all ELISA- and Western blot-positive specimens. We conclude that such a testing hierarchy can produce highly accurate results for identification of positive specimens in routine HIV testing and provides a practical alternative to conventional methods of HIV screening and confirmation.  相似文献   

20.
Two commercially available serologic tests for use in diagnosing Lyme borreliosis were evaluated by using a test panel comprised of sera from patients diagnosed with Lyme borreliosis, non-Lyme disease controls, and healthy subjects. The test methods examined were a Western blot assay and an immunodot assay. The study was initiated to determine how the immunodot assay, which contains purified and recombinant proteins to those borrelial antigens recommended for immunoglobulin M (IgM) detection in the Dearborn criteria, would compare with the Western blot assay as a confirmatory method for serologic diagnosis of Lyme borreliosis. Results obtained showed that the two test methods performed comparably for detecting IgG antibodies. For IgM antibody detection, the immunodot and Western blot assays had similar sensitivities; however, the immunodot assay was more specific and had greater positive predictive value than the Western blot assay. The results obtained indicate that the immunodot assay performs as well as or better than the Western blot assay for diagnosing Lyme borreliosis. Furthermore, because it uses a limited panel (n = 5) of antigens, the immunodot is easier to read and interpret than standard Western blots.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号