首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Objective: This study describes a single-center experience on percutaneously performed partial omentectomy procedure in pediatric peritoneal dialysis (PD) patients who showed early catheter dysfunction and required catheter replacement due to catheter flow obstruction. Materials and methods: We performed a retrospective review of clinical outcomes from pediatric PD patients who underwent percutaneous catheter replacement by pediatric nephrologists between November 1995 and December 2012. Partial omentectomy was performed in those patients in whom omental or adhesion trapping to the catheter tip was seen. Results: During the study period, catheter dysfunction that eventually required percutaneous catheter replacement occurred in 32 (23.7%) children. Of these, 9 patients were performed partial omentectomy. Mean age at initiation of PD and time of omentectomy was 97.48?±?46.06 and 98.53?±?45.55 months, respectively. Catheter dysfunction appeared after a mean 1.20?±?1.0 months. The causes of catheter dysfunction were omental wrapping and malposition. No peritonitis occurred before omentectomy. Mean total operation time was 60?±?8.83?min. No complications were encountered during the procedure. After omentectomy, mean catheter survival period was 5.92?±?6.88 months. A total of five peritonitis episodes occurred. Three patients were transferred to hemodialysis. Six patients were on PD treatment without any problem at the end of the first year of their follow-up. Two patients underwent kidney transplantation. Four patients were still on chronic PD treatment at the end of the study period. Conclusion: When performed by an experienced nephrologist, the performance of partial omentectomy by percutaneous route, when required, is an easy, safe and efficient therapeutic procedure in children on chronic PD treatment.  相似文献   

2.
Omental entrapment of the peritoneal dialysis catheter remains a common cause of flow dysfunction. Prophylactic omentectomy during catheter implantation is still followed with an incidence of flow obstruction as high as 10%. We describe indications and a technique for selective performance of omentopexy during laparoscopic catheter implantation that resulted in only a 0.7% obstruction rate in 153 consecutive patients as compared with a 12.8% rate in a preceding group of 78 consecutive patients. Laparoscopic omentopexy was performed during 9.2% of implant procedures and only when the omentum was found to extend to the retrovesical space. The procedure is simple, quick, and inexpensive to perform. Employing selective criteria for omentopexy eliminates the performance of unnecessary procedures. Actuarial analysis demonstrates that an operative strategy of selectively performing omentopexy for redundant omentum significantly improves catheter survival free of flow dysfunction (P < 0.0001).  相似文献   

3.
Peritoneal dialysis catheter outflow dysfunction frequently is caused by omentum or epiploic appendices blocking the side holes of the catheter tubing. Laparoscopy has been utilized increasingly to remedy mechanical blockage of the peritoneal device. This obviates the need for catheter replacement, permits early return to dialysis, and lowers the patient dropout rate from peritoneal dialysis as a modality for renal replacement therapy. We report a case of laparoscopic subtotal omentectomy to successfully resolve recurrent catheter obstruction that failed previous omentolysis and omentopexy. Using four port sites, the omental resection was accomplished using the harmonic scalpel. The procedure was performed on an ambulatory basis, dialysis was resumed after 1 week, and there were no infectious complications or port site leaks. We define terminology to standardize reporting of omentectomy. Our technique of laparoscopic omentectomy is described and compared to those of previously published reports. The role of laparoscopic omentectomy relative to other commonly used laparoscopic approaches to the obstructed peritoneal dialysis catheter is reviewed.  相似文献   

4.
BACKGROUND: This study describes a new technique of laparoscopic Tenckhoff catheter insertion. METHODS: During a 12-month period, 53 consecutive patients requiring insertion of peritoneal dialysis catheters were studied prospectively. A new technique of laparoscopic insertion was developed. RESULTS: Forty-eight patients out of 49 (98%) had successful insertion. Four patients were excluded with active peritonitis. There was an early complication rate of 8% (4/49) and a late complication rate of 14% (7/49). There was 12% overall failure of catheter with a mean follow up of 6 (1-13) months. CONCLUSION: This new laparoscopic technique maximizes the advantages of laparoscopic surgery and has complication rates which compare favourably with other open and laparoscopic techniques.  相似文献   

5.

Introduction

Automated peritoneal dialysis (APD) normally takes place overnight. Maintaining a stable PD catheter position, independent of body position, omental wrapping or catheter displacement secondary to bowel movements is essential in maintaining effective catheter function.

Methods

We developed a new procedure of catheter placement through combining and adapting several previously described operative techniques including laparoscopic placement of a curled double cuff Tenckhoff catheter with subcutaneous tunneling superior to the rectus sheet, an oblique course through the abdominal wall, deep entry into the pelvic peritoneum and directed placement of the curled tip within the pouch of Douglas. Retrospective analysis of catheter function was conducted, evaluating catheter position, function, complication rate and catheter survival against findings for current insertion techniques described within literature.

Results

Between March 2009 and November 2011, 54 patients underwent PD catheter insertion. The observation period was an average of 343?±?273 days. All patients received abdominal plain film showing optimal catheter position in 89 %. Reported catheter function was very good in 85.2 %, with no or few alarms per week during APD, moderate in 9.3 % with occasional minor dysfunctions (≤2 alarms per night), and poor in 5.6 %, with regular alarm disturbance. In one case, primary dysfunction led to catheter replacement. At completion, stable catheter function with occasional minor dysfunction was achieved in 52 of 54 cases. Catheter-related complications (leakage, hydrocele formation, infection and need for replacement) were observed in 14.8 %. At the end of the observation period, 55.6 % of catheters remained in use. Patient dropout occurred through death (18.5 %), renal transplantation (7.4 %), renal recovery (1.9 %), removal secondary to infection or dysfunction (9.3 %) and conversion to HD due to poor dialysis quality (7.4 %).

Conclusion

The above technique combines and optimises previously described laparoscopic catheter implantation techniques, allowing increased catheter stability resulting in an undisturbed catheter function suitable for APD.  相似文献   

6.

Background

Peritoneal dialysis (PD) is a cost-effective alternative to hemodialysis (HD). PD catheters have traditionally been inserted through a small open incision, but insertion using laparoscopic visualization has become increasingly popular and is associated with less catheter malfunction. The aim of this study was to compare costs of laparoscopic and open insertion strategies while taking into account postoperative complications and future salvage procedures.

Methods

A decision analysis model was constructed to simulate 1 y outcomes after PD catheter insertion by either the open or laparoscopic approach. Possible outcomes after PD catheter placement included functional catheter, infection, and catheter malfunction. Ultimately, patients continued with successful PD or switched to HD. Baseline probabilities, costs, and ranges were determined from a critical review of the literature. Sensitivity analyses were performed to determine the model strength over a range of clinically relevant probabilities.

Results

The total annual costs, including postoperative management and dialysis treatment, were $69,491 for laparoscopic insertion and $69,960 for open insertion. In case of a catheter malfunction, an initial attempt at salvage by fluoroscopy-guided wire manipulation cost less than a first attempt by laparoscopic repositioning.

Conclusions

When accounting for a year of postoperative management and treatment, laparoscopic insertion can be less costly than open insertion in the hands of an experienced surgeon. Despite higher initial costs, PD catheter insertion under laparoscopic visualization can have lower total costs due to fewer postoperative complications. With increasing emphasis on cost-effective care, laparoscopic insertion is a valuable tool for initiating PD.  相似文献   

7.
Asif A 《Minerva chirurgica》2005,60(5):417-428
Peritoneal dialysis (PD) catheter insertion can be accomplished by any 1 of 3 techniques. These include dissective or surgical, the blind or modified Seldinger, and laparoscopic techniques. The dissective technique solely utilized by surgeons, places the catheter by mini-laparotomy under general anesthesia. In the blind or modified Seldinger technique a needle is inserted into the abdomen, a guide-wire placed, a tract dilated and the catheter is inserted through a split-sheath, all without visualization of the peritoneal cavity. Of the various laparoscopes, peritoneoscopic insertion uses a small optical peritoneoscope for direct inspection of the peritoneal cavity and identification of a suitable site for the intraperitoneal portion of the catheter. Hence, of the 3 techniques, only the latter allows for the direct visualization of the intraperitoneal structures. This technique can be easily used by nephrologists as well as surgeons. Peritoneoscopic placement varies from traditional laparoscopic techniques by using: a much smaller scope (2.2 mm diameter) and puncture size, only one peritoneal puncture site, a device to advance the cuff into the musculature, air in the peritoneum rather than CO2, and local anesthesia rather than general anesthesia. Prospective randomized and nonrandomized studies have shown that PD catheters peritoneoscopically placed by nephrologists have less incidence of complications (infection, exit site leak) and longer catheter survival rates than those inserted surgically. The current review focuses on the peritoneoscopic insertion of PD catheter and presents some of the complicating issues (bowel perforation, catheter migration, and prior abdominal surgery) related to this procedure.  相似文献   

8.

Background

The purpose of this study was to determine the impact of omentectomy on peritoneal dialysis catheter failure rates in pediatric patients with renal failure.

Methods

A retrospective review of children undergoing peritoneal catheter placement was performed over a 22-year period. Children were segregated into those undergoing catheter placements with omentectomy or without.

Results

One hundred sixty-three patients were reviewed, with a 1:1.03 ratio of male to female patients. The mean age was 6.25 ± 5.58 years. Fifty-three percent underwent omentectomy. Catheter failure was observed in 63 children (39%). Catheter obstruction was identified in 36%. Peritonitis led to failure in 9.8%. Catheter failure rate was significantly reduced with the performance of omentectomy (23% without omentectomy vs 15% with omentectomy, P = .0054). Differences in time to catheter failure did not reach statistical significance in the omentectomy group (759 vs 280 days, P = .13).

Conclusions

Omentectomy conferred improved utility of peritoneal catheters in children. Omentectomy appears useful in children undergoing peritoneal dialysis catheter placement.  相似文献   

9.
Peritoneal dialysis (PD) is an effective treatment for end‐stage renal disease. There are several techniques of percutaneous PD catheter placement including trocar or Seldinger techniques. Placement can be performed with fluoroscopy and/or sonography or as a blind percutaneous procedure. Historically, percutaneous PD catheters have been placed in patients even if they had prior abdominal surgeries. The outcomes of percutaneous PD catheter placement in patients with complex abdomen (patients with two or more abdominal surgeries or known adhesions) are unknown. This study was carried out to determine the outcomes of percutaneous PD catheter placements using Seldinger technique with sonography and fluoroscopy in patients with complex abdomen. Preprocedure sonography was also used to identify site of adhesions and blood vessels. The goal was to see if ultrasound and fluoroscopy would support placement of PD catheters in patients with complex abdomens. There were total of 10 catheter placements in 10 patients with complex abdomen. The initial success rate was 100%. The patients had an average of 2.8 abdominal surgeries. The mean BMI was 28.4. There were no incidences of perforation or failed placements. One catheter was replaced due to outflow failure and one patient discontinued PD due to peri‐catheter leak. One year catheter survival was 80% . Our study demonstrates benefits of using ultrasonography and fluoroscopy during percutaneous PD catheter placement by the Seldinger technique in patients with complex abdomen.  相似文献   

10.
BACKGROUND AND PURPOSE: Maintaining long-term peritoneal catheter function for peritoneal dialysis is commonly threatened by problems with catheter obstruction. Multiple methods have been used to salvage nonfunctioning catheters, including omentopexy, catheter repositioning, and omentectomy. We report on our experience with a laparoscopic method of omentectomy and catheter fixation for salvage of nonfunctioning peritoneal dialysis catheters. PATIENTS AND METHODS: Thirteen patients with nonfunctioning peritoneal dialysis catheters underwent 16 laparoscopic procedures with the intent to restore function. Clinically, all patients presented with outflow obstruction. At initial presentation, all patients underwent diagnostic laparoscopy and a definitive procedure. In 12 patients, catheters were enveloped by omentum, and we performed laparoscopic omentectomy and catheter fixation to the anterior pelvic wall. In one patient, we identified a broken catheter and performed a laparoscopic omentectomy at the time of catheter replacement. One 10-mm and two 5-mm trocars were utilized. Omentectomy was performed using either endo-GIA stapled resection (2 patients) or the Harmonic Scalpel (11 patients). All trocar incisions (including the 5-mm site) were closed with a suture-passing (Carter-Thomason) device to provide water-tight closure in anticipation of immediate return to peritoneal dialysis. Patients were followed postoperatively for an average of 17 months (range 4-35 months). RESULTS: All patients' catheter function was restored intraoperatively with laparoscopic omentectomy and catheter fixation. Eight catheters remained functioning following omentectomy without further intervention. Five patients (38%) experienced repeat catheter malfunction and underwent laparoscopic exploration. Of these, three catheters (60%) were restored to function with laparoscopic manipulation alone. Three catheters were found encased in extensive adhesions. Laparoscopic adhesiolysis was successful in one patient and unsuccessful in one patient, who converted to hemodialysis. One patient failed laparoscopic salvage and required open laparotomy and fibrin clot removal to restore catheter function. One catheter was found to be obstructed within a pericolic hematoma. One catheter was found within residual omentum at the hepatic flexure. Both of these catheters were freed laparoscopically and continued to function at 12 and 16 months' follow-up. Complications included one episode of peritonitis, one case of postoperative ileus, and one trocar site hernia necessitating repair. The nephrologists were instructed that they could begin peritoneal dialysis on postoperative day 1. Seven patients resumed peritoneal dialysis without leak from trocar sites. The remaining patients received temporary hemodialysis through a central venous catheter and returned to peritoneal dialysis at the discretion of their nephrologists. CONCLUSIONS: Laparoscopic omentectomy with catheter fixation is a minimally invasive means of salvaging peritoneal dialysis catheters with outflow obstruction. Complications are few, and closure of laparoscopic incisions in water-tight fashion allows rapid return to peritoneal dialysis.  相似文献   

11.
Malfunction of a peritoneal dialysis (PD) catheter is common and usually occurs shortly after its insertion, due to omental wrapping. In fact, we have encountered this complication in 183 of 578 (31.6%) patients treated at our hospital since 1987. To overcome this problem, I have devised a new laparoscopic technique for catheter insertion. First, the omentum is fixed onto the peritoneum of the lateral abdominal wall at two points using a laparoscopic instrument (Pro Tack 5-mm Auto Suture, Norwalk, CT, USA) placed at the level of the umbilicus. The catheter is then introduced through the umblical trocar deep into the true pelvis. The cuff is positioned between the posterior rectus sheath and the rectus fibers, and the fascia is sewn. The catheter is then pulled through the 5-mm trocar site. This technique was successfully performed on ten patients with a median age of 46.1 years. There was no morbidity or any malfunction in continuous ambulatory peritoneal dialysis (CAPD) during follow-up periods ranging from 20 days to 9 months. Therefore, this new laparoscopic technique may prevent the obstruction caused by omental wrapping in CAPD. Received: October 13, 2000 / Accepted: May 15, 2001  相似文献   

12.

Background

Peritoneal dialysis (PD) is preferred over hemodialysis. The aim of this study was to evaluate our experience with laparoscopic PD catheter placement and omentectomy in children.

Methods

We reviewed all children (N = 21) who underwent laparoscopic placement of PD catheters and omentectomy. Ages ranged from 3 months to 16 years. Five children had previous major abdominal surgery and required extensive lysis of adhesions. During the same intervention, other surgical procedures were performed using laparoscopy or open technique, including umbilical hernia repair in 3, bilateral inguinal hernia repair in 3, ventral hernia repair in 2, gastrostomy in 4, kidney biopsy in 2, and cholecystectomy in 1.

Results

Thirteen children received successful kidney transplantation and no longer needed dialysis. Two children still have functioning PD catheters. One patient developed membrane failure and was converted to hemodialysis. Four patients recovered enough renal function and no longer need dialysis. There were no complications related to the laparoscopic procedure.

Conclusion

Laparoscopy is ideal for PD catheter placement. It facilitates omentectomy, and it allows for the catheter to be placed in the proper position under direct vision and for lysis of adhesions to increase peritoneal surface. Other abdominal procedures can be performed laparoscopically at the same time.  相似文献   

13.
BackgroundPeritoneal dialysis (PD) catheter obstruction often leads to surgical revision and may require transition to hemodialysis. The purpose of this study was to evaluate risk factors (including omentectomy) associated with early PD catheter obstruction (< 6 months from insertion).MethodsA retrospective review of all PD catheters inserted at a single high-volume referral center (2005–2018) was performed. 185 PD catheters were placed in 123 patients (45 female). Potential risk factors for early catheter obstruction were analyzed using Chi-square analysis (p < 0.05 considered statistically significant).ResultsMedian age at catheter insertion was 3.42 years (3 days–39 years). Early catheter obstruction occurred in 42 cases (22.7%). Median time to early obstruction was 24 days (3–118 days). Previous PD catheter placement (p = 0.9) or prior abdominal surgery (p = 0.89) was not associated with obstruction. Weight ≥ 10 kg (p = 0.011) and age ≥ 1 year (p = 0.048) were associated with a significantly higher incidence of obstruction. Overall, omentectomy was associated with a trend in reduction of early obstruction in patients with weight ≥ 10 kg (p = 0.08) and significantly in patients ≥ 1 year (p = 0.028).ConclusionEarly PD catheter obstruction appears to occur more often in older patients with a higher weight. Concomitant omentectomy seems beneficial at reducing early catheter obstruction events in those patients.Type of studyRetrospective comparative study.Level of evidenceIII.  相似文献   

14.
BACKGROUND AND OBJECTIVE: Peritoneal dialysis (PD) remains the generally accepted method for management of renal failure in chronic and acute renal failure. Despite the rapidly increasing use of continuous ambulatory peritoneal dialysis (CAPD) since its introduction, controversy persists as to the efficacy and exact role of the modality in the treatment of end stage renal failure. The aim of this paper is to present the experience with laparoscopic placement of a peritoneal dialysis catheter and starting the peritoneal dialysis on the same day. METHODS: The laparoscopic placement of a peritoneal dialysis catheter was performed on 11 patients (10 males and 1 female) with an average age of 35 years, over a 12-month period. The procedure was done using two 5 mm abdominal trocars. The precise position of the catheter on the pelvis was ensured laparoscopically. One to two liters exchange dialysis was used for every patient, and no leakage was recorded. RESULTS: The patients tolerated the procedure well. The peritoneal dialysis was started immediately. Patients were discharged after an overnight stay, and PD was carried out routinely. CONCLUSION: The results of laparoscopic placement of a peritoneal dialysis catheter show the following advantages: minimal incision; less surgical trauma; the procedure hastens the early start of peritoneal dialysis and has no complications.  相似文献   

15.
Percutaneous insertion of peritoneal dialysis catheters is theoretically most preferred by nephrologists because of the advantages of bedside performing, surgery independence, and minimal injury over other procedures of catheter placement such as open surgical dissection or laparoscopic operation. However, blindly placing catheters in the percutaneous procedure brings the risk of catheter malposition or bowel perforation; this largely retarded it's implementation. We had previously developed a novel technique termed “Wang's forceps‐assisted catheter insertion and fixation,” which had been successfully applied in the open surgical catheter insertion and displaced catheter reposition in our center. In this study, we further explored the possibility of applying the Wang's forceps in the procedure of percutaneous catheter insertion both in porcine model and patients with end stage renal disease (ESRD). A total of three miniature pigs successfully received percutaneous catheter insertion using Seldinger's technique with Wang's forceps assistance. The catheters were all placed in the right position and functioning well in dialysate drainage. This novel method of percutaneous catheter insertion was then performed on 20 ESRD patients. The procedure showed effective time‐saving with the average operating time of 29.2 ± 3.53 min and was well tolerated by patients with minimal pain and injury. During a follow‐up time of 6 months, no complications of catheter displacement, leakage, or blockade occurred. Our preliminary observation demonstrates that utilization of Wang's forceps in a percutaneous procedure conferred benefits of accurately placing and fixing catheters while preserving the merits of minimal invasion and simple performance.  相似文献   

16.
BACKGROUND: Starting continuous ambulatory peritoneal dialysis (CAPD) immediately after insertion of a peritoneal dialysis catheter is essential in end-stage renal disease (ESRD). In relation to the insertion methods, various mechanical and infectious complications may arise. In this study, we aimed to compare early complications of the laparoscopic tunneling method of CAPD placement that we developed recently in order to minimize the complications, with those of the conventional percutaneous method. SUBJECTS AND METHOD: Included in this study were 12 consecutive patients with ESRD to whom we introduced catheters for CAPD by way of laparoscopic tunneling between April 2003 and July 2003 and followed up for at least 6 months, and 30 patients to whom the catheters were placed percutaneously in the same time period with the same follow-up time. The complications seen during the first 6 months after catheter placement with these two different methods were compared. RESULTS: In all of the subjects, dialysis was started soon after catheter placement. No peroperative morbidity was seen in any of the patients. While with laparoscopic tunneling method no mechanical problem was seen, the percutaneous method resulted in early leakage in 10%, pericatheter bleeding in 3.3%, and hernia in 3.3% of the patients. As infectious complications, peritonitis occurred as one episode/36 patient-months in laparoscopic tunneling and one episode/22.5 patient-months in percutaneous method; catheter insertion site infection was seen in none in the laparoscopic method, while one episode/90patient-months was seen with the percutaneous method. Tunnel infection did not arise in any of the subjects. CONCLUSION: The authors of this study think that the peritoneal tunneling method for introducing CAPD, which has been recently developed and began to be routinely used by them, is rather safe in terms of early complications.  相似文献   

17.
Shen  Quanquan  Jiang  Xinxin  Shen  Xiaogang  Yu  Fangyan  Tu  Qiudi  Chen  Wangfang  Ye  Qing  Behera  Tapas Ranjan  He  Qiang 《International urology and nephrology》2017,49(8):1481-1488
Purpose

Peritoneal dialysis (PD) is a commonly accepted method of treating end-stage renal disease (ESRD). Various laparoscopic techniques for the placement of PD catheter have been described. In this study, we developed a novel modified laparoscopic technique for PD catheter placement and evaluated the early results.

Methods

A straight Tenckhoff PD catheter was placed employing the modified technique in 39 consecutive patients with ESRD from May 2013 to April 2016. The technique is laparoscopically guided intra-abdominal fixation of the PD catheter tip at one point by using suture passer hernia forceps. Individual information including sex, age, primary disease etiology, complications, surgical duration, morbidity, mortality and catheter survival was collected and analyzed.

Results

The modified laparoscopic procedure was effectively performed in all patients with a mean operative time of 45 ± 7 min. No conversions from laparoscopy to open surgery of catheter placement occurred. There was one case showing early pericatheter leakage. There were no serious complications, such as bleeding, abdominal wall hernias, distal catheter cuff extrusion and infections of the exit site or tunnel during surgery or the postoperative duration. No mortality was observed in this group of patients. The 6-month follow-up study showed 100% catheter-related complication-free survival.

Conclusions

Our modified laparoscopic intra-abdominal fixation technique using suture passer hernia forceps is a simple and safe method for PD catheter placement and is effective in minimizing the risk of catheter migration.

  相似文献   

18.
We describe a one-port laparoscopic technique for assisting in Tenchkoff catheter placement and salvaging obstructed ones in patients requiring continuous ambulatory peritoneal dialysis (CAPD). This unique technique enables diagnostic laparoscopy, adhesiolysis, repositioning of catheters, and omentectomy to be performed without laparotomy. Six patients were treated. Only one 10-mm port was required, using an operating laparoscope and an instrument introduced through the working channel of the laparoscope. Adhesiolysis was performed under laparoscopic vision; omentectomy and flushing of blocked catheters were carried out extracorporeally. The catheters were then repositioned to the pelvic cavity under laparoscopic vision. All patients were followed up for 6–10 months. No mechanical problem was noticed. Our one-port laparoscopic technique is a simple and effective method for treating patients who have mechanical problems with their peritoneal dialysis catheters. Received: 14 January 1997/Accepted: 14 April 1997  相似文献   

19.

Background

There is uncertainty regarding the optimal approach for surgical placement of peritoneal dialysis (PD) catheters in children. Operative technique, catheter selection, and patient variables (eg, age or prior surgical history) may influence catheter lifespan.

Methods

A retrospective review of all PD catheters placed at a tertiary children's medical center during a 6-year period was performed. Our primary outcome was catheter function 2 months after placement. Data were analyzed using Student 2-tailed t test or χ2 analysis.

Results

There were 121 PD catheters placed in 81 patients. The median primary functional catheter lifetime was 109 days. Primary PD catheter failure (within 2 months) occurred in 36 catheters (30%). Patients with primary catheter failure (8 ± 7 years) were younger than patients with a functioning catheter at 2 months (12 ± 5 years; P = .002). Catheters placed without simultaneous omentectomy were more likely to fail (P = .042). Catheter failure rate was not significantly different based upon operative technique or catheter type.

Conclusion

Omentectomy at the time of catheter placement decreased the risk of early catheter failure. In contrast, type of catheter or laparoscopic placement did not influence the likelihood of early catheter failure.  相似文献   

20.
The placement of a continuous ambulatory peritoneal dialysis (CAPD) catheter by conventional open surgical or trocar technique may cause a number of complications such as infection, hemorrhage, leakage, incisional hernia, and visceral organ perforation. Most complications are related to open surgery or insertion of the catheter with the guidewire without direct visualization. Insertion of the catheter laparoscopically under direct visualization has been previously described. The authors who described this technique used two or three ports for the camera and instruments. In this study we describe a laparoscopic technique for insertion of the peritoneal dialysis catheter under direct visualization with use of one-camera port and an accessory 2-mm umbilical incision. This prospective study was performed with the approval of the ethics committee of the Gazi University Hospital, in Ankara, Turkey. There were a total of eight patients: five males and three females, with an average age of 34.3 years (range, 11-54), who underwent laparoscopic CAPD insertion between 1997 and 2000. The catheter was inserted into the abdominal cavity 2 cm below the umbilicus. The subcutaneous tunnel was made with the assistance of a specially designed L-shaped trocar. All patients did well after the operation and had excellent cosmetic results. There was one leak in the early postoperative period, which was treated conservatively. The average operating time was 34.7 minutes (range, 25-45 minutes). The laparoscopic approach for peritoneal dialysis catheter insertion, for management of transmigrated CAPD catheters, and to resolve omental occlusions should be considered as an alternative to open surgery, especially for patients who have peritoneal adhesions secondary to a history of abdominal surgeries or recurrent peritonitis.  相似文献   