首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.  相似文献   

2.
We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean follow-up time for stable stems was 15.1 years (12.1 to 16.6). Survival of the stem at 15 years was 75.4% (95% confidence interval (CI) 67.3 to 83.5) with aseptic failure (including radiological failure) as the end-point, irrespective of the nature of the head and the quality of the cement mantle. Survival of the stem at 15 years was 79.1% (95% CI 69.8 to 88.4) and 67.1% (95% CI 51.3 to 82.9) with the CoCr alloy and ceramic heads, respectively. The quality of the cement mantle was graded as a function of stem coverage: stems with complete tip coverage (type 1) had an 84.9% (95% CI 77.6 to 92.2) survival at 15 years, compared with those with a poor tip coverage (type 2) which had a survival of only 22.4% (95% CI 2.4 to 42.4). The poor quality of the cement mantle and the implantation of an alumina head substantially lowered the survival of the stem. In our opinion, further use of the cemented titanium alloy straight-stem femoral components used in our series is undesirable.  相似文献   

3.
Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR. We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture. At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement. Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention.  相似文献   

4.
《Acta orthopaedica》2013,84(5):427-432
Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition from the use of a cemented collarless, polished, tapered stem to a cemented anatomic stem on the cumulative incidence of postoperative periprosthetic fracture (PPF).

Patients and methods — This prospective single-center cohort study comprises a consecutive series of 1,077 patients who underwent a cemented hip arthroplasty using either a collarless polished tapered stem (PTS group, n = 543) or an anatomic stem (AS group, n = 534). We assessed the incidence of PPF 2 years postoperatively and used a Cox regression model adjusted for age, sex, ASA class, cognitive impairment, BMI, diagnosis, and surgical approach for outcome analysis.

Results — Mean age at primary surgery was 82 years (49–102), 73% of the patients were female, and 75% underwent surgery for a femoral neck fracture. The PPF rate was lowered from 3.3% (n = 18) in the PTS group to 0.4% (n = 2) in the AS group. The overall complication rate was also lowered from 8.8% in the PTS group to 4.5% in the AS group. In the regression model only cognitive dysfunction (HR 3.8, 95% CI 1.4–10) and the type of stem (PTS vs AS, HR 0.1, CI 0.0–0.5) were correlated with outcome.

Interpretation — For elderly patients with poor bone quality use of cemented anatomic stems leads to a substantial reduction in periprosthetic fracture rate without increasing other complications.  相似文献   

5.
The clinical and radiographic outcomes of the cement-within-cement femoral stem exchange technique at revision hip arthroplasty were determined. Twenty-three revisions with a collarless polished double-taper stem design were prospectively monitored at up to 12 years. The most common indications for revision were recurrent dislocation and acetabular revision. Radiographic stem subsidence was measured by the Ein Bild Röentgen Analyse method. There was no stem re-revision and no radiographic loosening. Stem within cement subsidence, an intentional design feature of this stem, averaged 0.8 mm (range, 0-2 mm). The average subsidence was similar to that in primary hip arthroplasty. The excellent long-term results of cemented collarless polished taper stems for primary and revision hip arthroplasty can be extended even further by cement-within-cement exchange, which preserves the femur.  相似文献   

6.
The purpose of this study was to compare the intermediate results of total hip arthroplasty with a cemented, collarless, femoral prosthesis design (Exeter, Howmedica, Middlesex, UK and CPT, Zimmer, Warsaw, IN) with those of a cementless, collarless, porous-coated femoral component (PCA, Howmedica). A total of 151 hips in 128 patients were reviewed. In the cemented group, 85 Exeter-CPT prostheses were used in 71 patients with an average follow-up period of 6.5 years. In the uncemented group, 66 PCA prostheses were placed in 57 patients with an average follow-up period of 7 years. Harrington hip scores improved from 50.1 to 80.7 for the PGA group and from 49.5 to 87.3 for the Exeter-CPT group. The patient satisfaction rates were 89 and 96%, respectively. Sixty-eight patients with Exeter or CPT prostheses had excellent function and no significant thigh pain after 2 years. One Exeter stem was revised 10 years after the primary surgery because of localized osteolysis due to cement defect. Two Exeter sockets were revised because of aseptic loosening. In the PCA group, the incidence of thigh pain that persisted beyond 2 years was 39.4%, and there were high incidences of distal cortical hypertrophy (66.6%) and bead loosening (45.5%). Sixteen hips were revised for aseptic stem loosening, uncontrollable thight pain, or stem fracture (1 hip), and seven were revised because of migration and aseptic loosening of the socket. The cementless ingrowth stems failed earlier (around 5 years), whereas the cemented stems continued to perform well past 14 years. In this study, the cemented, collarless, collarless, porous-coated anatomic design at an average follow-up period of 7 years (range, 2–14 years).  相似文献   

7.
Between July 1986 and November 1989, 437 consecutive primary cemented total hip arthroplasties were performed using a straight-stemmed titanium alloy femoral component. Collared and collarless versions of this identical stem were randomly chosen by computer allowing a comparison between 213 collared stems (198 patients) and 224 collarless stems (209 patients). Diagnosis, sex, weight, and average age (72.8 years, collared; 72.0 years, collarless) were similar. Follow-up averaged 76 months (collared) and 72 months (collarless) with 49 patients followed for at least 10 years. Calcar-collar contact was noted in 205 hips (96%) on the initial postoperative radiograph. Early complications, including dislocations (5% each group), were similar. Late complications included 3 deep infections (2 collared, 1 collarless) and 2 postoperative femur fractures (1 each). Hip scores at the most recent follow-up averaged 91.2 and 90.1 in the collared and collarless groups. No or slight pain was noted in 93% of collared and 91.5% of collarless hips. Although no radiographic differences were noted in distal cortical hypertrophy, stem subsidence, and osteolysis, collarless hips lost significantly more medial femoral neck cortical bone (average 0.90 mm vs 0.63 mm). A higher incidence of radiolucent lines in femoral zone VI (20.7% vs 9.4%) was also noted in collarless hips.  相似文献   

8.
《The Journal of arthroplasty》2020,35(9):2525-2528
BackgroundTotal hip replacement (THR) after failed internal fixation of intertrochanteric femoral fractures is challenging. The aim of this study is to show the reliability of using standard cemented femoral stems in this operation.MethodsThis work included 107 THRs performed in 107 patients after failed treatment of intertrochanteric femoral fractures. The etiology of failure included 67 cases of failure of fixation, 16 cases of nonunion, 15 cases of avascular necrosis, and 9 cases of post-traumatic osteoarthritis. There were 48 males and 59 females. The mean age was 66 years (range 58-81). Failed dynamic hip screws were removed at the time of THR, and the screw holes were blocked with cement. All cases had cemented standard stem femoral prostheses.ResultsAt an average 7.4 years with a minimum of 5 years of follow-up, 102 cases had good clinical and radiological outcomes and 5 cases had fair outcomes. One patient was infected and required 2 stages of revision arthroplasty. Two cases had intraoperative proximal femoral crack, and were treated by cerclage wires. Two patients had early postoperative dislocations. No patients had late periprosthetic femoral fractures or implant loosening.ConclusionStandard cemented femoral stems are reliable and cost-effective prostheses in such cases. It is not necessary to bypass the distal screw hole by doubling the femoral canal diameter as long as the bone holes are covered by cement.  相似文献   

9.
We reviewed retrospectively the outcome of the treatment by impaction grafting of periprosthetic femoral fractures around loose stems in 106 patients with Vancouver type-B2 and type-B3 fractures. Eighty-nine patients had a cemented revision with impaction grafting and a long or short stem. The remaining 17 had cemented revision without impaction grafting. Fractures treated by impaction grafting and a long stem were more than five times likely to unite than those treated by impaction grafting and a short stem (odds ratio = 5.5, 95% confidence interval (CI) 1.54 to 19.6; p = 0.009). Furthermore, those with impaction grafting and a long stem were significantly more likely to unite than those with a long stem without impaction grafting (odds ratio = 4.07, 95% CI 1.10 to 15.0; p = 0.035). There was also a trend towards a higher rate of union in those treated by impaction grafting than in those without (odds ratio = 2.69, 95% CI 0.86 to 8.45; p = 0.090). Impaction grafting is being increasingly widely used for the restoration of femoral bone stock. It can be successfully applied to periprosthetic femoral fractures but a long stem should be used to bypass the distal fracture line.  相似文献   

10.

Purpose

The optimal design for a cemented femoral stem remains a matter of debate. Over time, the shape, surface finish and collar have all been modified in various ways. A clear consensus has not yet emerged regarding the relative merits of even the most basic design features of the stem. We undertook a prospective randomised trial comparing surface finish and the effect of a collar on cemented femoral component subsidence, survivorship and clinical function.

Methods

One hundred and sixty three primary total hip replacement patients were recruited prospectively and randomised to one of four groups to receive a cemented femoral stem with either a matt or polished finish, and with or without a collar.

Results

At two years, although there was a trend for increased subsidence in the matt collarless group, this was not statistically significant (p = 0.18). At a mean of 10.1 years follow-up, WOMAC scores for the surviving implants were good, (Range of means 89–93) without significant differences. Using revision or radiographic loosening as the endpoint, survivorship of the entire cohort was 93 % at 11 yrs, (CI 87–97 %). There were no significant differences in survivorship between the two groups with polished stems or the two groups with matt stems. A comparison of the two collarless stems demonstrated a statistically significant difference in survivorship between polished (100 %) and matt (88 %) finishes (p = 0.02).

Conclusions

In the presence of a collar, surface finish did not significantly affect survivorship or function. Between the two collarless groups a polished surface conferred an improved survivorship.  相似文献   

11.
The MS-30 (Morscher-Spotorno) cemented femoral stem is a straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement, manufactured from a FeCrNiMnMoNb-alloy. This paper documents the review of 4 original follow-ups performed at four orthopaedic hospitals: three at the author's institution (Basel/Switzerland 2, Pietra Ligure/Italy 1), and one at the University Orthopaedic Hospital of Heidelberg/ Germany. A total of 911 hips in 867 patients have been provided with the MS-30 stem. All stems were fixed with Palacos bone cement, the great majority with antibiotic (Gentamicine) loaded cement. The mean observation time was 10.2, 5.6, 10.2 and 6.5 years. One hundred and sixty-four hips were lost due to patients death, 121 patients were unable to come to the follow-up check. Ten patients only were lost to follow-up. The total number of hips with a clinical radiological follow-up was 597. The clinical and radiological assessment was in accordance with the International Documentation and Evaluation System (IDES) forms from the Institute of Documentation of the M.E. Müller Foundation in Berne/Switzerland. RESULTS The overall survivorship in the four follow-ups were 100% after 10 years, 98.4% and 99.2% after 5.5.years, 98.5% after 10 years and finally 96.1% after 6.5 years. The respective percentages of survival for aseptic loosening were 100%, 99.2%, 100%, 98.5% and 98.8%. CONCLUSION According to the NIH (National Institute of Health, United Kingdom) a survival rate of 95% regarding aseptic loosening justifies or even recommends further clinical use of the respective endoprosthesis system.  相似文献   

12.
BACKGROUND: Use of modern cementing techniques for fixation of femoral components in total hip arthroplasty has had excellent clinical and radiographic results in most patients. However, several authors have described early loosening of femoral components with roughened and precoated finishes. The purpose of this study was to examine the performance of the precoated Iowa stem, which has increased offset, and to compare the results with those of another cemented precoated femoral component with standard offset used at our institution. METHODS: We carried out a prospective analysis of 102 primary hybrid total hip arthroplasties (a cementless acetabular component and a cemented femoral component) performed with use of the Iowa femoral component in ninety-five patients at our institution. The Iowa stem was used in hips that required greater offset than is available with standard stems as determined by preoperative templating. The average age of the patients at the time of the index procedure was sixty-nine years. Sixteen patients (seventeen hips) died before the forty-eight-month minimum follow-up period had elapsed. Two patients were lost to follow-up, and radiographic follow-up was incomplete for one. The mean duration of clinical and radiographic follow-up of the remaining eighty-two hips in the seventy-six surviving patients was sixty-five months (range, forty-eight to 104 months). RESULTS: The average preoperative Harris hip score of 47 points (range, 16 to 69 points) improved to an average of 87 points (range, 24 to 100 points) at the time of the review. Two hips underwent femoral component revision. Four femoral stems were radiographically loose at an average of thirty-four months. Femoral osteolysis was seen in five hips (6 percent) at an average of fifty-four months postoperatively. No acetabular component was revised because of aseptic loosening. According to Kaplan-Meier analysis, the seven-year survival rate, with an end point of femoral revision, osteolysis, or stem debonding, was 90.6 percent (95 percent confidence interval, 0.87 to 0.94). CONCLUSIONS: The prevalence of revision, osteolysis, and loosening after total hip arthroplasty with the Iowa femoral component at our institution was higher than that seen in our series of Harris Precoat stems, which had a survival rate of 98.4 percent (95 percent confidence interval, 0.97 to 1.00) at ten years with the same end points. The design of the Iowa stem may make it difficult to achieve a good cement mantle, and, in combination with the geometry and increased offset of the stem, may compromise the long-term survival of this cemented femoral component.  相似文献   

13.
The mid-term results are reported of 2 uniquely different cemented stems implanted and followed prospectively by a single surgeon. The highly polished, collarless, tapered Exeter stem and the Endurance stem, a collared, roughened, satin finished stem, were inserted through a lateral approach using third-generation cement techniques. A total of 118 hips with the Exeter stem with an average follow-up of 7.25 years and 34 hips with the Endurance stem with an average follow-up of 4.57 years are included in the study. The Exeter patients had no revisions for aseptic loosening (0%) of the femoral stem. In contrast, the Endurance patients had 5 revisions and 2 impending revisions for aseptic loosening (20.5%) of the femoral stem with an average time to failure of 3.72 years. The excellent mid-term results of the Exeter stem support its ongoing use. By contrast, because of the poor early results of this modern cemented Endurance stem design, it is no longer used at our institution.  相似文献   

14.
Methods of stem fixation are a controversial aspect of revision TKA. We sought to determine which technique was superior by reviewing 475 revision TKAs done between 1986 and 2000. Of these 475 revisions, 286 major component revisions were done using 484 extended stems for fixation. Patients who died, patients who had less than 2 years follow up, or patients who had diaphyseal engaging stems were excluded from the study. The final data set included 113 revision TKAs with 202 metaphyseal engaging stems. Of the 202 stems, 107 were cemented whereas 95 were press-fit metaphyseal engaging stems. One hundred one of these were femoral stems and 101 were tibial stems. Using a modified Knee Society radiographic scoring system, 100 (93%) of the 107 implants with cemented stems were considered stable, seven (7%) were categorized as possibly loose requiring close followup, and none were loose. Of the 95 implants placed with cementless stems, only 67 (71%) were categorized as stable. Eighteen (19%) were possibly loose requiring close followup and 10 (10%) were loose (two tibial and eight femoral implants). We currently would urge caution in using cementless metaphyseal engaging stems for fixation in revision TKA.  相似文献   

15.
We reviewed 25 patients in whom a MUTARS megaprosthesis with a conical fluted stem had been implanted. There were three types of stem: a standard stem was used in 17 cases (three in the proximal femur, nine in the distal femur and five proximal tibia), a custom-made proximal femoral stem in four cases and a custom-made distal femoral stem in four cases. The mean age of the patients was 40.1 years (17 to 70) and the mean follow-up was for 2.5 years (0.9 to 7.4). At follow-up two patients had died from their disease: one was alive with disease and 22 were disease-free. One of 23 prostheses had been removed for infection and another revised to a cemented stem. The mean Musculoskeletal Tumor Society score was 24.9 (12 to 30) and the mean Karnofsky index was 82% (60% to 100%). There was no radiological evidence of loosening or subsidence. Stem stress shielding was seen in 11 patients and was marked in five of these. There were five complications, rupture of the extensor mechanism of the knee after extra-articular resection in two patients, deep venous thrombosis in one, septic loosening in one, and dislocation of the hip in one. The survival rate after seven years was 87% (95% confidence interval (CI) 83 to 91) for the patients and 95% (95% CI 91 to 99) for the megaprosthesis. A longer follow-up is needed to confirm these encouraging results.  相似文献   

16.
BACKGROUND: Poor bone stock in patients with osteonecrosis of the femoral head may be a reason for poor outcome after hip replacement. One way of studying bone quality is to measure implant migration. We thus investigated the clinical and radiographic results of cementless THR in younger patients with femoral head osteonecrosis. PATIENTS AND METHODS: We studied hips in 41 patients (mean age 48 (25-63) years) with a cementless hip arthroplasty after late stage osteonecrosis. Clinical evaluation was by the Harris hip score, the WOMAC score and the SF-36 score. Stem subsidence was measured with the Ein Bild Roentgen Analyse femoral component analysis (EBRA-FCA) at 3, 12, 24, 60, and 72 months after operation. The average duration of follow-up was 7(1-9) years, with less than 2 years for 2 patients. RESULTS: There was no revision of any hip. No radiographic or clinical stem loosening was seen. After 60 months, the cementless stems showed a median subsidence of -0.7 mm (95% CI: -0.9 to -0.2). No femoral osteolysis occurred. Femoral radiolucent lines, all < 1 mm, were seen in 10 hips. At the latest follow-up the Harris hip score was 83 (23-100) points. INTERPRETATION: Our findings for porous-coated stems in patients with femoral osteonecrosis indicate no greater risk of stem subsidence and rate of osteolysis after an average of 7 years follow-up. Thus, we continue to use uncemented stems in younger patients with femoral osteonecrosis. However, continued follow-up will be necessary to evaluate the long-term outcome.  相似文献   

17.
We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21?patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15?years following implantation. Its results are consistent with other polished tapered stem designs.  相似文献   

18.

Background

There has been controversy whether methylmethacrylate precoating of the cemented femoral stem is a solution for aseptic loosening or rather contributes to increased failure rates in cemented total hip arthroplasties.

Methods

On a retrospective basis, we analyzed 76 primary hybrid total hip arthroplasties from 63 patients with precoated, cemented femoral stems between October 1990 and December 1995. The mean age of the patients was 46.8 years (range, 22 to 77 years) with a minimum follow-up of 14 years (mean, 15.5 years; range, 14 to 19.5 years). Third generation cementing techniques were employed in all cases.

Results

Twenty-four out of 76 cases (31.6%) showed aseptic loosening of the femoral stems, of which 23 stems were revised at an average revision time of 8 years (range, 3 to 14.8 years). The main mode of loosening was cement-stem interface failure in 22 hips (91.7%). Twenty-one out of 24 failed hips (87.5%) demonstrated C2 cementing grades (p < 0.001). Kaplan-Meier survivorship analysis using radiographic aseptic loosening of the femoral stem as the endpoint for failure showed survival rates of 76.5% at 10 years (95% confidence interval [CI], 71.4 to 81.6) and 63.2% at 19 years (95% CI, 57.3 to 69.1).

Conclusions

An early failure of the precoated femoral stem in this study was mainly due to an insufficient cementing technique. Achievement of good cement mantle may improve the survival rates.  相似文献   

19.
Summary Mid- and long term stability is still the major challenge in total hip replacement (THR). A consecutive series of cemented 250 cases and of uncemented 250 cases was analyzed in a prospective follow-up study. The femoral component of the BiCONTACT hip stem system with the same design for cemented and uncemented implantation was used. While the cemented stems had a smooth surface, the cementless implants were proximally coated with a microporous titanium plasmaspray (Plasmapore®). Follow-up time averaged 7 years for cemented and 6.5 years for uncemented THRs. Follow-up rate was 88.7% in cases treated with cemented stems and 93.1% in cases treated with an uncemented stem. The rate of aseptic loosening was 1.2% for the cemented version and 0.4% for the uncemented one. Radiological loosening could be observed in another 1.2% of the cemented stems but was not found in the uncemented cases. Our data suggest excellent midterm stability of both the cemented and the uncemented version of the BiCONTACT hip stem system. Early aseptic loosening especially of the cemented titanium alloy straight stem has not occurred in our series as reported recently. The prosthesis design and follow-up time may therefore play an important role. The long-term results for both cemented and uncemented BiCONTACT prostheses of our series are still to be evaluated.  相似文献   

20.
A retrospective clinical and roentgenographic review was performed on 251 consecutive cemented total hip arthroplasties (THA) performed from 1978 to 1980 that had been followed a minimum of five years (range, five to seven years). All arthroplasties involved the use of a Harris Design II femoral stem, an intramedullary plug, a cement gun, and pulsatile lavage of both the acetabulum and the femoral canal. At the final follow-up examination, 98% of the patients had excellent results. The average Harris hip score was 47 points preoperative and 97 points postoperative. There were three definitely loose femoral stems, one probably loose, and two possibly loose. There was one loose acetabular component, no revisions or operations were performed. When comparing this series with a similar study, there were statistically improved results in all parameters. Results from this study of cemented THAs using contemporary techniques and prosthetic stem design represent the standard for comparison when evaluating alternative THA systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号