共查询到20条相似文献,搜索用时 750 毫秒
1.
Christian Carulli Armando Macera Fabrizio Matassi Roberto Civinini Massimo Innocenti 《Journal of orthopaedics and traumatology》2016,17(2):131-136
Background
Dislocation is one of the most frequent causes of failure of hemiarthroplasties of the hip, which is the most common treatment for femoral neck fractures in elderly patients. A revision with conversion to total hip arthroplasty is the gold standard in case of failure of closed reduction: however, the use of standard or modular components shows variable outcomes. The use of a dual mobility cup has been evaluated in patients with unstable implants, given the good outcomes obtained in primary and revision surgery. The aim of this study was to assess the results of revisions by dual mobility cups in unstable hemiarthroplasties.Materials and methods
Thirty-one patients (mean age 75.4 years) were retrospectively evaluated between 2006 and 2010 after conversion to total hip arthroplasty with dual mobility cups for recurrent dislocations. The mean number of dislocations was 2.6 (range 2–5). The evaluation was performed by the American Society of Anesthesiologists physical function score (ASA) and the Harris hip score, and several radiologic criteria.Results
The mean follow-up was 3.8 years. No recurrence of dislocation was recorded. The ASA score remained unchanged, and the mean Harris hip score improved from 62.2 before dislocation to 76.0 points postoperatively.Conclusions
Dual mobility cups may be a useful option in the treatment of a hemiarthroplasty dislocation. No risk of a new revision due to instability after insertion of dual mobility cups resulted in our experience, and this option may be strongly considered in cases of revisions of unstable hemiarthroplasties. Level of evidence IV.2.
Rick J. M. Sanders Bart A. Swierstra Jon H. M. Goosen 《Archives of orthopaedic and trauma surgery》2013,133(7):1011-1016
Introduction
Total hip arthroplasty (THA) is one of the treatment options in patients with cerebral palsy (CP) with painful osteoarthritis of the hip. However, the risk of dislocation of the prosthesis is higher in patients with CP when compared with physically normal patients. In this retrospective study of ten consecutive cases, we hypothesized that the use of a dual-mobility cup could reduce this risk of dislocation combined with good functional results.Materials and methods
From January 2008 until October 2010, eight patients (ten hips) with CP who consecutively received a THA using a dual-mobility cup were identified. At the time of surgery, the average age of the patient group was 54 years (range 43–61). Latest follow-up took place after on average 39 months (range 22–56 months). All patients or their caregivers were interviewed by telephone. They were asked if dislocation of the prosthesis had occurred. To evaluate quality of life and health in general, patients completed the SF-36 questionnaire.Results
None of the prostheses had dislocated at the latest follow-up. Reoperation was needed in one patient after a periprosthetic fracture. Radiologic evaluation showed a mean cup inclination of 46 (range 27–58). On average, the quality of life of patients in this study was found to be limited in particular on the domains of physical health and functioning, while a fair to good score was measured at the six other different domains.Conclusion
The use of a dual-mobility cup in THA in patients with CP can lead to favourable results with respect to dislocation and clinical outcome. 相似文献3.
Christoffer C. J?rgensen Per Kjaersgaard-Andersen S?ren Solgaard Henrik Kehlet 《Archives of orthopaedic and trauma surgery》2014,134(11):1615-1622
Study design
Retrospective review of prospectively collected data.Objective
To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors.Methods
Prospective data on preoperative patient characteristics from six Danish arthroplasty departments with similar fast-track approaches were cross-referenced with the Danish National Patient Registry for complete 90-day follow-up on readmissions, including emergency-room contacts. Complete patient files and postoperative radiographs were reviewed in case of dislocations. Unadjusted comparisons were made using t test/Chi-square analyses, while evaluation of risk factors potentially predisposing to dislocations was done using uni- and multivariate regression analysis.Results
A total of 2,734 consecutive unselected procedures were available for analysis, of which 65 (2.4 %) had dislocations. Of these, eight were during index admission and five were treated and discharged from the emergency room. Mechanisms of dislocation were most often movement while supine or sitting for the first 30 days and due to squatting/bending from day 31 to 90. The 65 patients with dislocations had suboptimal cup placement in 34 (52.3 %), and a femoral head size of <36 mm in 20 (30.8 %) cases. Predisposing factors of dislocation were age ≥75 [OR:1.96 (1.18–3.38)], pharmacologically treated psychiatric disease [OR:2.37 (1.29–4.36)] and department of surgery [OR:2.27 (1.31–3.40)] but not hospital stay of <4 days. Departments with recommendations for activity restrictions had fewer dislocations than a department without restrictions.Conclusions
Patients ≥75 years and with pharmacologically treated psychiatric disease may be at increased risk of dislocations after fast-track total hip arthroplasty. Further studies including detailed information on patient and prosthesis characteristics, and activity restrictions are needed to reduce the risk of dislocation. 相似文献4.
Andrej Moličnik Marko Hanc Gregor Rečnik Zmago Krajnc Mitja Rupreht Samo K. Fokter 《European journal of orthopaedic surgery & traumatology : orthopedie traumatologie》2014,24(6):911-917
Purpose
The purpose of this study was to evaluate early functional results of revision hip arthroplasty with pelvic bone loss revised with porous tantalum (PT) acetabular components.Methods
Twenty-five consecutive patients (25 hips) with loose acetabular components after total hip arthroplasty with a minimum of Paprosky IIa pelvic bone loss treated with PT cups with and without modular augments were retrospectively reviewed. Clinical outcomes were assessed using Harris hip score, and Western Ontario and McMaster Universities scores. Mean follow-up was 20.5 months and no patient was lost during follow-up.Results
The average Harris hip score, and Western Ontario and McMaster Universities scores improved from 40 and 36 preoperatively to 79 and 73 postoperatively, respectively. No statistically significant differences in functional outcome scores were found between the group with moderate (Paprosky IIa, b) and severe (Paprosky IIc or more) acetabular bone loss. At the most recent radiographic evaluation, 24 cups demonstrated no lucent lines and 1 cup had lucent lines but remained well fixed. One cup was revised for traumatic dislocation but was found well fixed at open reduction. There were no septic or aseptic failures in this series.Conclusion
While awaiting longer-term follow-up studies, trabecular metal components show sufficient primary stability and appear suitable for revision hip arthroplasty with acetabular bone loss. 相似文献5.
M. van Heumen P. J. C. Heesterbeek B. A. Swierstra G. G. Van Hellemondt J. H. M. Goosen 《Journal of orthopaedics and traumatology》2015,16(1):15-20
Background
A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We hypothesized that use of a new-generation dual mobility cup in revision arthroplasty prevents dislocation in patients with a history of recurrent dislocation of the THA.Materials and methods
We performed a retrospective cohort study of patients receiving an isolated acetabular revision with a dual mobility cup for recurrent dislocation of the prosthesis with a minimum follow-up of 1 year. Kaplan–Meier survival analyses were performed with dislocation as a primary endpoint and re-revision for any reason as a secondary endpoint.Results
Forty-nine consecutive patients (50 hips) were included; none of the patients was lost to follow-up. The median follow-up was 29 months (range 12–66 months). Two patients died from unrelated causes. Survival after 56 months was 100 % based on dislocation and 93 % (95 % CI 79–98 %) based on re-revision for any reason. Radiologic analysis revealed no osteolysis or radiolucent lines around the acetabular component during the follow-up period.Conclusion
The dual mobility cup is an efficient solution for instability of THA with a favorable implant survival at 56 months.Level of evidence
Level 4, retrospective case series. 相似文献6.
Jean Louis Prudhon François Steffann André Ferreira Régis Verdier Thierry Aslanian Jacques Caton 《International orthopaedics》2014,38(12):2463-2468
Purpose
Dislocation is a frequent complication in total hip arthroplasty (THA) revision. Cup fixation is the second concern. In order to know outcomes at two years, we prospectively followed a continuous series of 78 patients to demonstrate that cementless dual-mobility cup (DMC) used in revision THA is safe as regards dislocation risk and bone fixation.Method
We enrolled 78 consecutive patients (79 cases) in a prospective study. Mean interval between index surgery and revision was 12.9 years. Mean age at revision was 75.5 years. Two types of cementless DMC were used: a standard DMC in 68 cases with low-grade bone defect (Paprosky grade 1 and 2), and a specific design reconstruction DMC in 11 cases with severe bone loss (Paprosky grade 3).Results
At two years of follow-up, 68 patients were reviewed; four were lost to follow-up., and six patients were deceased. We identified three types of situations at risk:standard risk (33 cases), Paprosky grade 1 or 2; medium risk (37 cases), revision for recurrent instability (21), periprosthetic fractures (14) or severe loosening Paprosky grade 3 without femorotomy (2); high risk (nine cases), revision for severe loosening with a femorotomy. One (1.3 %) patient dislocated her hip at one month without recurrence. Revision rate for dislocation was 0 %; two (2.7 %) early mechanical failures occurred.Conclusion
Considering outcomes of this series, cementless DMC can be suggested in THA revision surgery. 相似文献7.
Ho-Rim Choi David Anderson Scott Foster Matthew Beal Jo Ann Lee Christopher Barr Henrik Malchau Joseph McCarthy Young-Min Kwon 《International orthopaedics》2013,37(10):1905-1910
Purpose
This study evaluates acetabular cup position in the setting of revision total hip arthroplasty (THA) with severe acetabular bone defects.Methods
With a definition of safe zone of abduction (30–50°) and anteversion (5–25°), acetabular cup position was measured by a digital image analysis program for 34 patients with Paprosky type III acetabular bone defects.Results
There were 24 cups (71 %) for abduction and 26 cups (76 %) for anteversion located in the safe zone. Nineteen cups (56 %) were within the safe zone for both abduction and anteversion. There was no dislocation, however one cup out of the safe zone resulted in early cup failure due to aseptic loosening.Conclusions
The acetabular cup positioning in patients with Paprosky type III defects was 'optimal' in half of the cases. The prevalence of optimal acetabular cup position was similar to those reported in primary THA, suggesting that the presence of a large acetabular bone defect may not be a significant risk factor for suboptimal acetabular cup positioning in the setting of revision THA. 相似文献8.
9.
Mohsen Mardani-Kivi Mahmoud Karimi-Mobarakeh Kamran Asadi Keyvan Hashemi-Motlagh Khashayar Saheb-Ekhtiari 《European journal of orthopaedic surgery & traumatology : orthopedie traumatologie》2013,23(7):785-790
Background
Historically, performing a successful hip joint replacement in patients aged fewer than 30 years has been an orthopedic challenge. The newer generation of prostheses and surgical techniques has the potential to increase the longevity of implants. The purpose of this study was to evaluate the outcomes of cementless hip arthroplasty in patients aged fewer than 30 years.Materials and methods
In this cross-sectional study, 41 patients (46 hips) were studied with a mean age of 24, 4 (from 17 to 30 years) of whom underwent cementless metal–polyethylene hip arthroplasty from 2004 to 2007. The Harris hip score (HHS) was used to assess the functional consequences. Patients were followed up in terms of early complications (thrombophlebitis of the lower limbs, dislocation, hematoma and infection) and late complications (aseptic loosening, dislocation and reoperation) at weeks 3 and 6, at 3 and 6 months, 1 year after surgery and annually thereafter.Results
Patients were followed for an average of 5 years and 2 months (from 51 to 82 months). One early complication (symptomatic thrombophlebitis) and one late dislocation (2.2 %) were observed. There were no cases of aseptic loosening or osteolysis at the end of follow-up. The preoperative HHS was 59.6 (from 41 to 76), which rose to 82 and 83.5 after the 1-year and final follow-up, respectively, which was a significant increase.Conclusions
Hip arthroplasty using a new generation of cementless proximal porous prosthesis with resistant polyethylene to cover the joint surfaces in patients aged fewer than 30 years is satisfactory and is accompanied by low complications. 相似文献10.
Philippe Hernigou Louis Ratte François Roubineau Jacques Pariat Guillaume Mirouse Isaac Guissou Jerome Allain Charles Henri Flouzat Lachaniette 《International orthopaedics》2013,37(7):1219-1223
Purpose
Total hip arthroplasty (THA) has been efficacious for treating hip fractures in healthy older patients. However, in those patients with fractures a widely variable prevalence of dislocation has been reported, partly because of varying durations of follow up for this specific end-point. The purpose of the present study was to determine the cumulative risk of dislocation in these patients with fractures and to investigate if retentive cups decrease the risk of dislocation.Methods
Between 2000 and 2005, 325 patients with neck fracture underwent primary THA using a retentive (325 hips) cup. The results of these 325 acetabular cups were compared to 180 THA without retentive cups performed for neck fractures in the same hospital between 1995 and 2000 by the same surgical team. The mean age of the 505 patients was 75 years (range 65–85). All patients were followed for a minimum of five years for radiographic evidence of implant failure. The patients were followed at routine intervals and were specifically queried about dislocation. The cumulative risk of dislocation and recurrent dislocation was calculated with use of the Kaplan–Meier method.Results
For patients without retentive cups, the cumulative risk of a first-time dislocation was 5 % at one month and 12 % at one year and then rose at a constant rate of approximately 1 % every year to 16 % at five years. For patients with retentive cups, the cumulative risk of a first-time dislocation was 1 % at one month, 2 % at one year and then did not changed at five years. There were no differences in the mortality rates or in loosening rates among the treatment groups. The rate of secondary surgery was highest in the group without retentive (10 % for recurrent dislocation) compared with 1 % in the group treated with retentive cups. In absence of retentive cups, multivariate analysis revealed that the relative risk of dislocation for female patients (as compared with male patients) was 2.1 and that the relative risk for patients who were 80 years old or more (as compared with those who were less than 80 years old) was 1.5. Two underlying diagnoses occurring during follow up—cognitively impaired patients or neurologic disease—were also associated with a significantly greater risk of dislocation in absence of retentive cup. For these patients the risk was also decreased with a retentive cup.Conclusion
With standard cups the incidence of dislocation is highest in the first year after arthroplasty and then continues at a relatively constant rate for the life of the arthroplasty. Patients at highest risk are old female patients and those with a diagnosis of neurologic disease. Retentive cups in these patients are an effective technique to prevent post-operative hip dislocation. 相似文献11.
Introduction
We report how changes to our total hip arthroplasty (THA) surgical practise lead to a decrease in early hip dislocation rates.Methods
Group B consisted of 421 consecutive primary THA operations performed via a posterior approach. The operative technique included a meticulous repair of the posterior capsule, alignment of the acetabular cup with the transverse acetabular ligament (TAL) and a 36-mm-diameter femoral head. We compared the dislocation rates and cost implications of this technique to a historical control Group A consisting of 389 patients. The control group had their THA performed with no repair of the capsule, no identification of the TAL and all received a 28-mm-diameter head. Our primary outcome is the rate of early hip dislocation and we hypothesised that we can reduce the rate of early hip dislocation with this new regime.Results
In Group B there were no early dislocations (within 6?months) and two (0.5?%) dislocations within 18?months; minimum follow-up time was 18?months with a range of (18–96?months). This compared to a 1.8?% early dislocation rate and a 2.6?% rate at 18?months in Group A; minimum follow-up time was 60?months with a range of (60–112?months). These results were statistically significant (p?=?0.006).Conclusion
We suggest that when primary hip arthroplasty is performed through a posterior approach, a low early dislocation rate can be achieved using the described methods. 相似文献12.
Ke Liu Jia Zheng Yi Jin Yong-qiang Zhao 《European journal of orthopaedic surgery & traumatology : orthopedie traumatologie》2014,24(1):51-55
Purpose
To investigate the clinical outcome of two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement prosthesis.Materials and methods
Forty-one patients, who suffered from an infection after hip replacement or internal fixation of femoral neck and trochanteric fractures, were treated with a two-stage revision hip arthroplasty and followed up for an average of 37 months. All the patients were implanted with antibiotic-impregnated cement prosthesis as one-stage treatment and were then managed with two-stage revision hip arthroplasty after 12–24 weeks. During the follow-up, Merle d’Aubigné hip score and Harris score were employed for assessment of hip function, and infection recurrence was observed.Results
According to Merle d’Aubigné hip score, 16 patients (39.2 %) were excellent, 19 (46.3 %) were good, 6 (14.6 %) were moderate, and no bad result and the average score was 15.42. Mean Harris score of preoperation, interval period, and postoperation was 46.7, 66.5, and 92.3, respectively. There was no infection recurrence.Conclusion
Two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement prosthesis has a satisfying clinical outcome. 相似文献13.
Peter Helwig Lukas Konstantinidis Anja Hirschmüller Anke Bernstein Oliver Hauschild Norbert P. Südkamp Björn G. Ochs 《International orthopaedics》2013,37(1):15-19
Purpose
One possibility in hip arthroplasty revisions is to combine a modular ceramic head with an adapter or sleeve in isolated acetabular cup replacement. This study consisted of an experimental part to analyse the reliability of taper damage predictions, and a clinical part to analyse the outcomes of modular ceramic head implantation in a case series of isolated cup replacements.Methods
Analysis of scratch size on 11 explanted hip stems were examined macroscopically and by stereomicroscopy to classify damage to the conical taper. The second part consisted of a prospective analysis of isolated cup revisions using a modular ceramic head, performed in two orthopedic centres.Results
Analysis of scratch size on the taper yielded inter-observer correlations of 0.545–0.909; comparison with stereomicroscopic data recordings yielded a moderate correlation, with values between 0.545 and 0.090. The clinical study included 47 isolated acetabular cup revisions involving modular ceramic heads. Ceramic head failure did not occur during the average clinical and radiological observation period of 26 months. Mean Harris Hip Score (HHS) at follow-up was 70 points.Conclusion
From these results, it can be concluded that damage to the implanted stem taper cannot be reliably predicted intraoperatively. Nevertheless, the clinical outcomes did show that there were no problems with the ceramic heads over the short observation period. The application of modular ceramic heads in younger patients requiring isolated cup replacement requires proper risk-benefit analysis, but is possible and appears to be a safe procedure. 相似文献14.
J. G. Cowie G. S. Turnball A. M. Ker S. J. Breusch 《Archives of orthopaedic and trauma surgery》2013,133(5):695-700
Introduction
Expectations of patients requiring total hip replacement have become higher than in the past and are often well beyond pain relief and improved mobility. Return to work and sporting activity are important factors to be considered when advising patients preoperatively. The objective of this study was to analyse the return to sports and work rates in patients still in employment and to analyse potential influencing factors.Materials and methods
Patients under the age of 65 who had a total hip replacement performed at a university teaching hospital were identified from the local arthroplasty database and contacted. Pre and postoperative levels of sporting activity and work were recorded. We also recorded the time point at which they returned to these activities.Results
285 total hip replacements were carried out on 239 patients. At the time of follow-up 170 of the patients were working. The mean length of time to return to work was 13.9 weeks (SD 7.7). 78 % returned to work without any restrictions, 18.6 % in heavy manual jobs. The mean time taken to return to sports or similar physical activities was 18.8 weeks (SD 8.8) weeks. Those with a lower body mass index returned to work and sporting activities faster.Conclusions
Our data show that the majority of patients undergoing total hip replacement can expect to return to work and sporting activities within 4–6 months. Activities at work are often initially limited and physical performance may not fully return to the expected level. Patients with a high body mass index take longer to return to work and sporting activities. 相似文献15.
Kazutaka So Yutaka Kuroda Shuichi Matsuda Haruhiko Akiyama 《Archives of orthopaedic and trauma surgery》2013,133(6):869-874
Background
Surgical revision after failed total hip replacement is a technically challenging procedure. The aim of this study was to analyze the long-term results of revision total hip replacement using a cemented long femoral component and identify factors that influence the results.Methods
We retrospectively reviewed 34 hips in 33 patients who had undergone revision total hip replacement using a cemented long femoral component between 1994 and 2001. Hip function was evaluated according to the scoring system of the Japanese Orthopaedic Association. Radiographic examination was performed for evaluation of stem loosening, and its possible risk factors were investigated.Results
The mean follow-up duration was 11.3 years (9–15). Perioperative complications included intraoperative femoral cortex perforation (six hips, 18 %), dislocation (five hips, 15 %), deep venous thrombosis (one hip, 3 %) and postoperative periprosthetic fracture (one hip, 3 %). The mean preoperative Japanese Orthopaedic Association hip score was 50.3 ± 14.9 vs 78.2 ± 11.5 at the latest follow-up. The Kaplan–Meier survival rate at 15 years, calculated using radiological failure or re-revision of the femoral component for any reason as the end point, was 87 or 100 %, respectively. The failure-free survival rate for the subgroup with a good-quality cement mantle was significantly higher than that for the subgroup with poor quality (p = 0.033).Conclusions
The quality of cementation was identified as a significant risk factor for further loosening. Revision total hip replacement using a cemented long femoral component yielded satisfactory long-term results in this series. 相似文献16.
Marion Opperer Yuo-yu Lee Francisco Nally Alvaro Blanes Perez Kaveh Goudarz-Mehdikhani Alejandro Gonzalez Della Valle 《International orthopaedics》2016,40(4):703-708
Purpose
In order to diminish total hip arthroplasty (THA) dislocation rate, surgeons strive to achieve adequate component orientation, offset and limb length. In addition, dislocation rate can theoretically be reduced by increasing head diameter and by choosing implants with favorable head-to-neck and cup-to head ratios. We assessed nine radiographic and implant-related parameters associated with an increased risk of dislocation in patients who sustained a dislocation and in those with a stable arthroplasty.Methods
A total of 1,487 consecutive elective primary THAs performed by a single surgeon, using a posterolateral approach were reviewed at an average follow-up of 18 months (range, 1–112). Fixation was hybrid in 85 % of hips and non-cemented in 15 %. Thirty-eight patients (38 hips, 2.5 %) sustained at least one dislocation. Thirty-seven patients with good quality, standardized anteroposterior radiographs were selected as a “study group”. The study group was matched-paired (1:3) with patients who had a stable arthroplasty based on gender, age, BMI, diagnosis and follow-up. Variables compared between the groups included: head size, cup size, head-to-neck ratio, cup-to-head ratio, leg-length discrepancy, offset, cup inclination, cup version and cup orientation based on the safe zone defined by Lewinnek et al.Results
None of the nine parameters showed a statistically significant difference between the groups.Discussion
In this study, 90 % of patients who developed a dislocation had properly positioned acetabular components. In addition, the vast majority of patients in the study group had adequate restoration of limb length and offset. The results of our study may be useful for the orthopedic surgeons who discuss instability following THA surgery, particularly in patients with radiographically sound reconstructions.17.
Jeong Joon Yoo Hyeong Jo Yoon Pil Whan Yoon Young-Kyun Lee Hee Joong Kim 《Archives of orthopaedic and trauma surgery》2013,133(3):413-419
Purpose
In an alumina-on-alumina total hip arthroplasty (THA), recommended with a small inclination angle <45°, the acetabular component (cup) may be positioned more medially to be covered almost completely by host bone. The purpose of this study was to identify the correlating factors and to evaluate the outcomes of medial placement of the cup in patients with alumina-on-alumina THAs.Methods
Using the propensity score matching with age, gender, body mass index, initial diagnosis, and the length of follow-up as variables, 38 hips with a medialized cup and 38 hips with a non-medialized one were identified from 389 hips in 347 who patients underwent primary alumina-on-alumina THA and followed up for more than 7 years. Clinical and radiological outcomes were compared between the two groups.Results
Preoperative acetabular medial wall thickness and the cup inclination angle were significantly smaller in the medialization group compared to the non-medialization group. Center edge angle, cup size, and coverage by host bone were not significantly different between the two groups. The hip center of rotation was significantly medialized in the medialization group. The Harris hip scores were not significantly different between the two groups. No component loosening or osteolysis was observed and no revision was required in either groups.Conclusions
Thin acetabular medial wall and a small inclination angle of the cup were the correlating factors of medial placement of the cup in patients who underwent an alumina-on-alumina THA. Medial placement did not lead to differences in the clinical or radiological outcomes. 相似文献18.
Yuntong Zhang Yang Tang Chuncai Zhang Xue Zhao Yang Xie Shuogui Xu 《International orthopaedics》2013,37(6):1039-1044
Purpose
Dislocation following total hip arthroplasty (THA) with the posterior approach has been quite a common and bothering complication. Previous researches suggest that careful repair of the posterior structures significantly reduces this risk. The purposes of the present study were to describe a modified posterior soft tissue repair procedure in THA using a suture anchor (TwinFix Ti 5.0, Smith & Nephew, Andover, MA) and evaluate the early postoperative dislocation rate.Methods
From July 2004 to June 2008, 220 consecutive primary total hip arthroplasties were performed using the modified surgical approach. The average age in the group was 46.4 years (range from 21 to 90) at the time of the procedure. The rate of postoperative hip dislocation, as well as any signs of complications related to the technique, has been observed and analyzed in this study.Results
There was no postoperative dislocation following primary THA in 220 cases, and no signs of complications related to the technique, such as greater trochanteric fractures and sciatic nerve palsy, have been noted in any of the cases at their most recent follow-up.Conclusions
These initial results demonstrate that the modified repair in THA using the suture anchor can serve as an effective and reliable mean for prevention of early postoperative dislocation 相似文献19.
Mohamed Yassin Chris Mitchell Mohammed Diab Colin Senior 《International orthopaedics》2014,38(5):1073-1075
Purpose
Venous thromboembolism (VTE) is a recognised post-operative complication of major lower limb joint arthroplasty. Current National Institute for Health and Clinical Excellence (NICE) guidelines suggest the use of both mechanical and pharmacological prophylaxis following hip and knee replacement. Since the introduction of enhanced recovery programmes following hip and knee arthroplasty the requirement for routine pharmacological VTE prophylaxis has been questioned. The purpose of this study was to assess the efficacy of pharmacological prophylaxis against symptomatic VTE in patients undergoing hip and knee arthroplasty under an enhanced recovery programme.Methods
Symptomatic VTE incidence was audited in 1,100 patients undergoing primary or revision total hip or knee arthroplasty at the same hospital with only mechanical prophylaxis from 2007 to 2009. Following addition of chemical prophylaxis (enoxaparin) symptomatic VTE incidence in 522 patients undergoing primary or revision total hip or knee arthroplasty from 2011 to 2012 was re-audited.Results
In the mechanical prophylaxis group incidence of DVT was 0.73 % [95 % confidence interval (CI) 0.37–1.43 %] and incidence of pulmonary embolism (PE) 0.91 % (95 % CI 0.49–1.67 %). Following addition of pharmacological prophylaxis incidence of DVT was 0.57 % (95 % CI 0.20–1.68 %) and incidence of PE 1.15 % (95 % CI 0.53–2.48 %).Conclusions
We found no statistically significant difference in symptomatic VTE incidence following the addition of enoxaparin. We question whether routine pharmacological prophylaxis still has a role following total hip and knee arthroplasty. Peri-operative optimisation, including post-operative analgesia and mobility, with current enhanced recovery programmes may be sufficient. As anticoagulants carry increased risk of post-operative bleeding and wound ooze, in addition to significant cost implications, their role remains controversial. 相似文献20.
P. Schwabe S. Märdian C. Perka K.-D. Schaser 《Operative Orthopadie und Traumatologie》2016,28(2):91-103